Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Radiother Oncol ; 196: 110317, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38679202

RESUMO

BACKGROUND AND PURPOSE: Concerns over chest wall toxicity has led to debates on treating tumors adjacent to the chest wall with single-fraction stereotactic ablative radiotherapy (SABR). We performed a secondary analysis of patients treated on the prospective iSABR trial to determine the incidence and grade of chest wall pain and modeled dose-response to guide radiation planning and estimate risk. MATERIALS AND METHODS: This analysis included 99 tumors in 92 patients that were treated with 25 Gy in one fraction on the iSABR trial which individualized dose by tumor size and location. Toxicity events were prospectively collected and graded based on the CTCAE version 4. Dose-response modeling was performed using a logistic model with maximum likelihood method utilized for parameter fitting. RESULTS: There were 22 grade 1 or higher chest wall pain events, including five grade 2 events and zero grade 3 or higher events. The volume receiving at least 11 Gy (V11Gy) and the minimum dose to the hottest 2 cc (D2cc) were most highly correlated with toxicity. When dichotomized by an estimated incidence of ≥ 20 % toxicity, the D2cc > 17 Gy (36.6 % vs. 3.7 %, p < 0.01) and V11Gy > 28 cc (40.0 % vs. 8.1 %, p < 0.01) constraints were predictive of chest wall pain, including among a subset of patients with tumors abutting or adjacent to the chest wall. CONCLUSION: For small, peripheral tumors, single-fraction SABR is associated with modest rates of low-grade chest wall pain. Proximity to the chest wall may not contraindicate single fractionation when using highly conformal, image-guided techniques with sharp dose gradients.


Assuntos
Dor no Peito , Radiocirurgia , Parede Torácica , Humanos , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Parede Torácica/efeitos da radiação , Feminino , Masculino , Dor no Peito/etiologia , Idoso , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Dosagem Radioterapêutica , Neoplasias Torácicas/radioterapia , Relação Dose-Resposta à Radiação
2.
Front Oncol ; 14: 1378449, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38660134

RESUMO

Purpose: Create a comprehensive automated solution for pediatric and adult VMAT-CSI including contouring, planning, and plan check to reduce planning time and improve plan quality. Methods: Seventy-seven previously treated CSI patients (age, 2-67 years) were used for creation of an auto-contouring model to segment 25 organs at risk (OARs). The auto-contoured OARs were evaluated using the Dice Similarity Coefficient (DSC), 95% Hausdorff Distance (HD95), and a qualitative ranking by one physician and one physicist (scale: 1-acceptable, 2-minor edits, 3-major edits). The auto-planning script was developed using the Varian Eclipse Scripting API and tested with 20 patients previously treated with either low-dose VMAT-CSI (12 Gy) or high-dose VMAT-CSI (36 Gy + 18 Gy boost). Clinically relevant metrics, planning time, and blinded physician review were used to evaluate significance of differences between the auto and manual plans. Finally, the plan preparation for treatment and plan check processes were automated to improve efficiency and safety of VMAT-CSI. Results: The auto-contours achieved an average DSC of 0.71 ± 0.15, HD95 of 4.81 ± 4.68, and reviewers' ranking of 1.22 ± 0.39, indicating close to "acceptable-as-is" contours. Compared to the manual CSI plans, the auto-plans for both dose regimens achieved statistically significant reductions in body V50% and Dmean for parotids, submandibular, and thyroid glands. The variance in the dosimetric parameters decreased for the auto-plans as compared to the manual plans indicating better plan consistency. From the blinded review, the auto-plans were marked as equivalent or superior to the manual-plans 88.3% of the time. The required time for the auto-contouring and planning was consistently between 1-2 hours compared to an estimated 5-6 hours for manual contouring and planning. Conclusions: Reductions in contouring and planning time without sacrificing plan quality were obtained using the developed auto-planning process. The auto-planning scripts and documentation will be made freely available to other institutions and clinics.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38493902

RESUMO

PURPOSE: We conducted a multi-institutional dosimetric audit between FLASH and conventional dose rate (CONV) electron irradiations by using an anatomically realistic 3-dimensional (3D) printed mouse phantom. METHODS AND MATERIALS: A computed tomography (CT) scan of a live mouse was used to create a 3D model of bony anatomy, lungs, and soft tissue. A dual-nozzle 3D printer was used to print the mouse phantom using acrylonitrile butadiene styrene (∼1.02 g/cm3) and polylactic acid (∼1.24 g/cm3) simultaneously to simulate soft tissue and bone densities, respectively. The lungs were printed separately using lightweight polylactic acid (∼0.64 g/cm3). Hounsfield units (HU), densities, and print-to-print stability of the phantoms were assessed. Three institutions were each provided a phantom and each institution performed 2 replicates of irradiations at selected anatomic regions. The average dose difference between FLASH and CONV dose distributions and deviation from the prescribed dose were measured with radiochromic film. RESULTS: Compared with the reference CT scan, CT scans of the phantom demonstrated mass density differences of 0.10 g/cm3 for bone, 0.12 g/cm3 for lung, and 0.03 g/cm3 for soft tissue regions. Differences in HU between phantoms were <10 HU for soft tissue and bone, with lung showing the most variation (54 HU), but with minimal effect on dose distribution (<0.5%). Mean differences between FLASH and CONV decreased from the first to the second replicate (4.3%-1.2%), and differences from the prescribed dose decreased for both CONV (3.6%-2.5%) and FLASH (6.4%-2.7%). Total dose accuracy suggests consistent pulse dose and pulse number, although these were not specifically assessed. Positioning variability was observed, likely due to the absence of robust positioning aids or image guidance. CONCLUSIONS: This study marks the first dosimetric audit for FLASH using a nonhomogeneous phantom, challenging conventional calibration practices reliant on homogeneous phantoms. The comparison protocol offers a framework for credentialing multi-institutional studies in FLASH preclinical research to enhance reproducibility of biologic findings.

4.
J Appl Clin Med Phys ; 25(3): e14225, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38213084

RESUMO

PURPOSE: A well-known limitation of multi-leaf collimators is that they cannot easily form island blocks. This can be important in mantle region therapy. Cerrobend photon blocks, currently used for supplementary shielding, are labor-intensive and error-prone. To address this, an innovative, non-toxic, automatically manufactured photon block using 3D-printing technology is proposed, offering a patient-specific and accurate alternative. METHODS AND MATERIALS: The study investigates the development of patient-specific photon shielding blocks using 3D-printing for three different patient cases. A 3D-printed photon block shell filled with tungsten ball bearings (BBs) was designed to have similar dosimetric properties to Cerrobend standards. The generation of the blocks was automated using the Eclipse Scripting API and Python. Quality assurance was performed by comparing the expected and actual weight of the tungsten BBs used for shielding. Dosimetric and field geometry comparisons were conducted between 3D-printed and Cerrobend blocks, utilizing ionization chambers, imaging, and field geometry analysis. RESULTS: The quality assurance assessment revealed a -1.3% average difference in the mass of tungsten ball bearings for different patients. Relative dose output measurements for three patient-specific blocks in the blocked region agreed within 2% of each other. Against the Treatment Planning System (TPS), both 3D-printed and Cerrobend blocks agreed within 2%. For each patient, 6 MV image profiles taken through the 3D-printed and Cerrobend blocks agreed within 1% outside high gradient regions. Jaccard distance analysis of the MV images against the TPS planned images, found Cerrobend blocks to have 15.7% dissimilarity to the TPS, while that of the 3D-printed blocks was 6.7%. CONCLUSIONS: This study validates a novel, efficient 3D-printing method for photon block creation in clinical settings. Despite potential limitations, the benefits include reduced manual labor, automated processes, and greater precision. It holds potential for widespread adoption in radiation therapy, furthering non-toxic radiation shielding.


Assuntos
Proteção Radiológica , Tungstênio , Humanos , Fótons , Radiometria , Impressão Tridimensional , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica
5.
Int J Radiat Oncol Biol Phys ; 119(3): 1001-1010, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38171387

RESUMO

PURPOSE: Ultrahigh-dose-rate (FLASH) irradiation has been reported to reduce normal tissue damage compared with conventional dose rate (CONV) irradiation without compromising tumor control. This proof-of-concept study aims to develop a deep learning (DL) approach to quantify the FLASH isoeffective dose (dose of CONV that would be required to produce the same effect as the given physical FLASH dose) with postirradiation mouse intestinal histology images. METHODS AND MATERIALS: Eighty-four healthy C57BL/6J female mice underwent 16 MeV electron CONV (0.12 Gy/s; n = 41) or FLASH (200 Gy/s; n = 43) single fraction whole abdominal irradiation. Physical dose ranged from 12 to 16 Gy for FLASH and 11 to 15 Gy for CONV in 1 Gy increments. Four days after irradiation, 9 jejunum cross-sections from each mouse were hematoxylin and eosin stained and digitized for histological analysis. CONV data set was randomly split into training (n = 33) and testing (n = 8) data sets. ResNet101-based DL models were retrained using the CONV training data set to estimate the dose based on histological features. The classical manual crypt counting (CC) approach was implemented for model comparison. Cross-section-wise mean squared error was computed to evaluate the dose estimation accuracy of both approaches. The validated DL model was applied to the FLASH data set to map the physical FLASH dose into the isoeffective dose. RESULTS: The DL model achieved a cross-section-wise mean squared error of 0.20 Gy2 on the CONV testing data set compared with 0.40 Gy2 of the CC approach. Isoeffective doses estimated by the DL model for FLASH doses of 12, 13, 14, 15, and 16 Gy were 12.19 ± 0.46, 12.54 ± 0.37, 12.69 ± 0.26, 12.84 ± 0.26, and 13.03 ± 0.28 Gy, respectively. CONCLUSIONS: Our proposed DL model achieved accurate CONV dose estimation. The DL model results indicate that in the physical dose range of 13 to 16 Gy, the biologic dose response of small intestinal tissue to FLASH irradiation is represented by a lower isoeffective dose compared with the physical dose. Our DL approach can be a tool for studying isoeffective doses of other radiation dose modifying interventions.


Assuntos
Aprendizado Profundo , Camundongos Endogâmicos C57BL , Animais , Camundongos , Feminino , Intestinos/efeitos da radiação , Intestinos/patologia , Dosagem Radioterapêutica , Jejuno/efeitos da radiação , Jejuno/patologia , Estudo de Prova de Conceito
6.
Pract Radiat Oncol ; 14(2): e165-e172, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38048988

RESUMO

PURPOSE: The purpose of this work is to develop a method to automate the treatment planning process of craniospinal irradiation (CSI) using volumetric modulated arc therapy. METHODS AND MATERIALS: Two scripts were developed using the Eclipse Scripting Application Programming Interface to perform auto-plan preparation and optimization. Ten patients (age, 5-44 years) previously treated at our institution with low dose volumetric modulated arc therapy CSI (prescription of 12 Gy) before total body irradiation were selected to evaluate the efficacy of the proposed auto-planning process. Paired t tests compared the dosimetric indices of the auto-plans to the manually generated clinical plans. All plans were normalized to 95% of planning target volume (PTV) coverage with the prescription dose. Two physicians and one physicist were asked to evaluate the manual plans and auto-plans of each patient in a blinded retrospective review and to indicate clinical acceptability and which plans were preferred for treatment. RESULTS: Compared with the manual CSI plans, the auto plans obtained significant reductions in Dmean to the parotids, submandibular glands, larynx, thyroid, and significant reduction in the plan PTV Dmax and D0.03 cc. The standard deviation range of the dosimetric parameters was greatly reduced for auto plans (range, 0.1-1.3 Gy) relative to manual plans (range, 0.4-5.9 Gy) indicating better plan consistency. Among the 10 patients, the auto-plans were preferred over the manual plans 90% of the time by the reviewing experts. The required time for auto-planning was approximately 1 hour compared with estimated 4 or more hours for manual planning. CONCLUSIONS: Reductions in planning time without sacrifices in plan quality were obtained using the auto-planning process compared with manual planning. Variation in plan quality was also reduced. The auto-planning scripts will be made freely available to other institutions and clinics.


Assuntos
Radiação Cranioespinal , Médicos , Radioterapia de Intensidade Modulada , Humanos , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Instalações de Saúde , Glândula Parótida
7.
Pract Radiat Oncol ; 2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-37981253

RESUMO

PURPOSE: Lung blocks for total-body irradiation are commonly used to reduce lung dose and prevent radiation pneumonitis. Currently, molten Cerrobend containing toxic materials, specifically lead and cadmium, is poured into molds to construct blocks. We propose a streamlined method to create 3-dimensional (3D)-printed lung block shells and fill them with tungsten ball bearings to remove lead and improve overall accuracy in the block manufacturing workflow. METHODS AND MATERIALS: 3D-printed lung block shells were automatically generated using an inhouse software, printed, and filled with 2 to 3 mm diameter tungsten ball bearings. Clinical Cerrobend blocks were compared with the physician drawn blocks as well as our proposed tungsten filled 3D-printed blocks. Physical and dosimetric comparisons were performed on a linac. Dose transmission through the Cerrobend and 3D-printed blocks were measured using point dosimetry (ion-chamber) and the on-board Electronic-Portal-Imaging-Device (EPID). Dose profiles from the EPID images were used to compute the full-width-half-maximum and to compare with the treatment-planning-system. Additionally, the coefficient-of-variation in the central 80% of full-width-half-maximum was computed and compared between Cerrobend and 3D-printed blocks. RESULTS: The geometric difference between treatment-planning-system and 3D-printed blocks was significantly lower than Cerrobend blocks (3D: -0.88 ± 2.21 mm, Cerrobend: -2.28 ± 2.40 mm, P = .0002). Dosimetrically, transmission measurements through the 3D-printed and Cerrobend blocks for both ion-chamber and EPID dosimetry were between 42% to 48%, compared with the open field. Additionally, coefficient-of-variation was significantly higher in 3D-printed blocks versus Cerrobend blocks (3D: 4.2% ± 0.6%, Cerrobend: 2.6% ± 0.7%, P < .0001). CONCLUSIONS: We designed and implemented a tungsten filled 3D-printed workflow for constructing total-body-irradiation lung blocks, which serves as an alternative to the traditional Cerrobend based workflow currently used in clinics. This workflow has the capacity of producing clinically useful lung blocks with minimal effort to facilitate the removal of toxic materials from the clinic.

8.
Radiother Oncol ; 188: 109906, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37690668

RESUMO

BACKGROUND AND PURPOSE: The impact of radiotherapy (RT) at ultra high vs conventional dose rate (FLASH vs CONV) on the generation and repair of DNA double strand breaks (DSBs) is an important question that remains to be investigated. Here, we tested the hypothesis as to whether FLASH-RT generates decreased chromosomal translocations compared to CONV-RT. MATERIALS AND METHODS: We used two FLASH validated electron beams and high-throughput rejoin and genome-wide translocation sequencing (HTGTS-JoinT-seq), employing S. aureus and S. pyogenes Cas9 "bait" DNA double strand breaks (DSBs) in HEK239T cells, to measure differences in bait-proximal repair and their genome-wide translocations to "prey" DSBs generated after various irradiation doses, dose rates and oxygen tensions (normoxic, 21% O2; physiological, 4% O2; hypoxic, 2% and 0.5% O2). Electron irradiation was delivered using a FLASH capable Varian Trilogy and the eRT6/Oriatron at CONV (0.08-0.13 Gy/s) and FLASH (1x102-5x106 Gy/s) dose rates. Related experiments using clonogenic survival and γH2AX foci in the 293T and the U87 glioblastoma lines were also performed to discern FLASH-RT vs CONV-RT DSB effects. RESULTS: Normoxic and physioxic irradiation of HEK293T cells increased translocations at the cost of decreasing bait-proximal repair but were indistinguishable between CONV-RT and FLASH-RT. Although no apparent increase in chromosome translocations was observed with hypoxia-induced apoptosis, the combined decrease in oxygen tension with IR dose-rate modulation did not reveal significant differences in the level of translocations nor in their junction structures. Furthermore, RT dose rate modality on U87 cells did not change γH2AX foci numbers at 1- and 24-hours post-irradiation nor did this affect 293T clonogenic survival. CONCLUSION: Irrespective of oxygen tension, FLASH-RT produces translocations and junction structures at levels and proportions that are indistinguishable from CONV-RT.

9.
Front Oncol ; 13: 1237037, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37621682

RESUMO

Purpose: The integration of 3D-printing technology into radiation therapy (RT) has allowed for a novel method to develop personalized electron field-shaping blocks with improved accuracy. By obviating the need for handling highly toxic Cerrobend molds, the clinical workflow is significantly streamlined. This study aims to expound upon the clinical workflow of 3D-printed electron cutouts in RT and furnish one year of in-vivo dosimetry data. Methods and materials: 3D-printed electron cutouts for 6x6 cm, 10x10 cm, and 15x15 cm electron applicators were designed and implemented into the clinical workflow after dosimetric commissioning to ensure congruence with the Cerrobend cutouts. The clinical workflow consisted of four parts: i) the cutout aperture was extracted from the treatment planning system (TPS). A 3D printable cutout was then generated automatically through custom scripts; ii) the cutout was 3D-printed with PLA filament, filled with tungsten ball bearings, and underwent quality assurance (QA) to verify density and dosimetry; iii) in-vivo dosimetry was performed with optically stimulated luminescence dosimeters (OSLDs) for a patient's first treatment and compared to the calculated dose in the TPS; iv) after treatment completion, the 3D-printed cutout was recycled. Results: QA and in-vivo OSLD measurements were conducted (n=40). The electron cutouts produced were 6x6 cm (n=3), 10x10 cm (n=30), and 15x15 cm (n=7). The expected weight of the cutouts differed from the measured weight by 0.4 + 1.1%. The skin dose measured with the OSLDs was compared to the skin dose in the TPS on the central axis. The difference between the measured and TPS doses was 4.0 + 5.2%. Conclusion: The successful clinical implementation of 3D-printed cutouts reduced labor, costs, and removed the use of toxic materials in the workplace while meeting clinical dosimetric standards.

10.
bioRxiv ; 2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37034651

RESUMO

The molecular and cellular mechanisms driving the enhanced therapeutic ratio of ultra-high dose-rate radiotherapy (FLASH-RT) over slower conventional (CONV-RT) radiotherapy dose-rate remain to be elucidated. However, attenuated DNA damage and transient oxygen depletion are among several proposed models. Here, we tested whether FLASH-RT under physioxic (4% O 2 ) and hypoxic conditions (≤2% O 2 ) reduces genome-wide translocations relative to CONV-RT and whether any differences identified revert under normoxic (21% O 2 ) conditions. We employed high-throughput rejoin and genome-wide translocation sequencing ( HTGTS-JoinT-seq ), using S. aureus and S. pyogenes Cas9 "bait" DNA double strand breaks (DSBs), to measure differences in bait-proximal repair and their genome-wide translocations to "prey" DSBs generated by electron beam CONV-RT (0.08-0.13Gy/s) and FLASH-RT (1×10 2 -5×10 6 Gy/s), under varying ionizing radiation (IR) doses and oxygen tensions. Normoxic and physioxic irradiation of HEK293T cells increased translocations at the cost of decreasing bait-proximal repair but were indistinguishable between CONV-RT and FLASH-RT. Although no apparent increase in chromosome translocations was observed with hypoxia-induced apoptosis, the combined decrease in oxygen tension with IR dose-rate modulation did not reveal significant differences in the level of translocations nor in their junction structures. Thus, Irrespective of oxygen tension, FLASH-RT produces translocations and junction structures at levels and proportions that are indistinguishable from CONV-RT.

11.
Adv Radiat Oncol ; 8(5): 101186, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37035034

RESUMO

Purpose: The aim of this study was to apply the Six Sigma methodology and failure mode and effect analysis (FMEA) to mitigate errors in intensity modulated radiation therapy (IMRT) and stereotactic body radiation therapy (SBRT) treatment planning with the first clinical installation of RefleXion X1. Methods and Materials: The Six Sigma approach consisted of 5 phases: define, measure, analyze, improve, and control. The define, measure, and analyze phases consisted of process mapping and an FMEA of IMRT and SBRT treatment planning on the X1. The multidisciplinary team outlined the workflow process and identified and ranked the failure modes associated with the plan check items using the American Association of Physicists in Medicine Task Group 100 recommendations. Items with the highest average risk priority numbers (RPNs) and severity ≥7 were prioritized for automation using the Eclipse Scripting Application Programming Interface (ESAPI). The "improve" phase consisted of developing ESAPI scripts before the clinical launch of X1 to improve efficiency and safety. In the "control" phase, the FMEA ranking was re-evaluated 1 year after clinical launch. Results: Overall, 100 plan check items were identified in which the RPN values ranged from 10.2 to 429.0. Fifty of these items (50%) were suitable for automation within ESAPI. Of the 10 highest-risk items, 8 were suitable for automation. Based on the results of the FMEA, 2 scripts were developed: Planning Assistant, used by the planner during preparation for planning, and Automated Plan Check, used by the planner and the plan checker during plan preparation for treatment. After 12 months of clinical use of the X1 and developed scripts, only 3 errors were reported. The average prescript RPN was 138.0, compared with the average postscript RPN of 47.8 (P < .05), signifying a safer process. Conclusions: Implementing new technology in the clinic can be an error-prone process in which the likelihood of errors increases with increasing pressure to implement the technology quickly. To limit errors in clinical implementation of the novel RefleXion X1 system, the Six Sigma method was used to identify failure modes, establish quality control checks, and re-evaluate these checks 1 year after clinical implementation.

12.
Brachytherapy ; 22(4): 446-460, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37024350

RESUMO

PURPOSE: To provide a systematic review of the applications of 3D printing in gynecological brachytherapy. METHODS: Peer-reviewed articles relating to additive manufacturing (3D printing) from the 34 million plus biomedical citations in National Center for Biotechnology Information (NCBI/PubMed), and 53 million records in Web of Science (Clarivate) were queried for 3D printing applications. The results were narrowed sequentially to, (1) all literature in 3D printing with final publications prior to July 2022 (in English, and excluding books, proceedings, and reviews), and then to applications in, (2) radiotherapy, (3) brachytherapy, (4) gynecological brachytherapy. Brachytherapy applications were reviewed and grouped by disease site, with gynecological applications additionally grouped by study type, methodology, delivery modality, and device type. RESULTS: From 47,541 3D printing citations, 96 publications met the inclusion criteria for brachytherapy, with gynecological clinical applications compromising the highest percentage (32%), followed by skin and surface (19%), and head and neck (9%). The distribution of delivery modalities was 58% for HDR (Ir-192), 35% for LDR (I-125), and 7% for other modalities. In gynecological brachytherapy, studies included design of patient specific applicators and templates, novel applicator designs, applicator additions, quality assurance and dosimetry devices, anthropomorphic gynecological applicators, and in-human clinical trials. Plots of year-to-year growth demonstrate a rapid nonlinear trend since 2014 due to the improving accessibility of low-cost 3D printers. Based on these publications, considerations for clinical use are provided. CONCLUSIONS: 3D printing has emerged as an important clinical technology enabling customized applicator and template designs, representing a major advancement in the methodology for implantation and delivery in gynecological brachytherapy.


Assuntos
Braquiterapia , Radioisótopos do Iodo , Humanos , Dosagem Radioterapêutica , Braquiterapia/métodos , Impressão Tridimensional
13.
Int J Radiat Oncol Biol Phys ; 117(2): 482-492, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37105403

RESUMO

PURPOSE: Ultrahigh-dose-rate (UHDR) radiation therapy (RT) has produced the FLASH effect in preclinical models: reduced toxicity with comparable tumor control compared with conventional-dose-rate RT. Early clinical trials focused on UHDR RT feasibility using specialized devices. We explore the technical feasibility of practical electron UHDR RT on a standard clinical linear accelerator (LINAC). METHODS AND MATERIALS: We tuned the program board of a decommissioned electron energy for UHDR electron delivery on a clinical LINAC without hardware modification. Pulse delivery was controlled using the respiratory gating interface. A short source-to-surface distance (SSD) electron setup with a standard scattering foil was configured and tested on an anthropomorphic phantom using circular blocks with 3- to 20-cm field sizes. Dosimetry was evaluated using radiochromic film and an ion chamber profiler. RESULTS: UHDR open-field mean dose rates at 100, 80, 70, and 59 cm SSD were 36.82, 59.52, 82.01, and 112.83 Gy/s, respectively. At 80 cm SSD, mean dose rate was ∼60 Gy/s for all collimated field sizes, with an R80 depth of 6.1 cm corresponding to an energy of 17.5 MeV. Heterogeneity was <5.0% with asymmetry of 2.2% to 6.2%. The short SSD setup was feasible under realistic treatment conditions simulating broad clinical indications on an anthropomorphic phantom. CONCLUSIONS: Short SSD and tuning for high electron beam current on a standard clinical LINAC can deliver flat, homogenous UHDR electrons over a broad, clinically relevant range of field sizes and depths with practical working distances in a configuration easily reversible to standard clinical use.


Assuntos
Elétrons , Neoplasias , Humanos , Radiometria/métodos , Aceleradores de Partículas , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica
14.
Int J Radiat Oncol Biol Phys ; 117(1): 96-104, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37001762

RESUMO

PURPOSE: The Audio-Visual Assisted Therapeutic Ambience in Radiotherapy (AVATAR) system was the first published radiation therapy (RT)-compatible system to reduce the need for pediatric anesthesia through video-based distraction. We evaluated the feasibility of AVATAR implementation and effects on anesthesia use, quality of life, and anxiety in a multicenter pediatric trial. METHODS AND MATERIALS: Pediatric patients 3 to 10 years of age preparing to undergo RT at 10 institutions were prospectively enrolled. Children able to undergo at least 1 fraction of RT using AVATAR without anesthesia were considered successful (S). Patients requiring anesthesia for their entire treatment course were nonsuccessful (NS). The PedsQL3.0 Cancer Module (PedsQL) survey assessed quality of life and was administered to the patient and guardian at RT simulation, midway through RT, and at final treatment. The modified Yale Preoperative Anxiety Scale (mYPAS) assessed anxiety and was performed at the same 3 time points. Success was evaluated using the χ2 test. PedsQL and mYPAS scores were assessed using mixed effects models with time points evaluated as fixed effects and a random intercept on the subject. RESULTS: Eighty-one children were included; median age was 7 years. AVATAR was successful at all 10 institutions and with photon and proton RT. There were 63 (78%) S patients; anesthesia was avoided for a median of 20 fractions per patient. Success differed by age (P = .04) and private versus public insurance (P < .001). Both patient (P = .008) and parent (P = .006) PedsQL scores significantly improved over the course of RT for patients aged 5 to 7. Anxiety in the treatment room decreased for both S and NS patients over RT course (P < .001), by age (P < .001), and by S versus NS patients (P < .001). CONCLUSIONS: In this 10-center prospective trial, anesthesia avoidance with AVATAR was 78% in children aged 3 to 10 years, higher than among age-matched historical controls (49%; P < .001). AVATAR implementation is feasible across multiple institutions and should be further studied and made available to patients who may benefit from video-based distraction.


Assuntos
Anestesia , Radioterapia (Especialidade) , Humanos , Criança , Pré-Escolar , Estudos de Viabilidade , Estudos Prospectivos , Qualidade de Vida
15.
Cancer Invest ; : 1-8, 2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-33899635

RESUMO

We present a patient with widespread PCGD-TCL of the bilateral arms and legs, who underwent radiotherapy with 34 Gy in 17 fractions using circumferential VMAT and 3-D printed bolus to the four extremities prior to planned stem cell transplant, who was then found to have progression in the liver, lung, and skin, followed by drastic regression of all in and out-of-field lesions on imaging 1.5 months later. The cause of regression may be related to a radiation-induced abscopal effect from the immunomodulatory effects of radiation, or related to immune reactivation in the setting of cessation of systemic immunosuppressive agents.

16.
Radiother Oncol ; 175: 203-209, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36030934

RESUMO

BACKGROUND AND PURPOSE: We describe a multicenter cross validation of ultra-high dose rate (UHDR) (>= 40 Gy/s) irradiation in order to bring a dosimetric consensus in absorbed dose to water. UHDR refers to dose rates over 100-1000 times those of conventional clinical beams. UHDR irradiations have been a topic of intense investigation as they have been reported to induce the FLASH effect in which normal tissues exhibit reduced toxicity relative to conventional dose rates. The need to establish optimal beam parameters capable of achieving the in vivo FLASH effect has become paramount. It is therefore necessary to validate and replicate dosimetry across multiple sites conducting UHDR studies with distinct beam configurations and experimental set-ups. MATERIALS AND METHODS: Using a custom cuboid phantom with a cylindrical cavity (5 mm diameter by 10.4 mm length) designed to contain three type of dosimeters (thermoluminescent dosimeters (TLDs), alanine pellets, and Gafchromic films), irradiations were conducted at expected doses of 7.5 to 16 Gy delivered at UHDR or conventional dose rates using various electron beams at the Radiation Oncology Departments of the CHUV in Lausanne, Switzerland and Stanford University, CA. RESULTS: Data obtained between replicate experiments for all dosimeters were in excellent agreement (±3%). In general, films and TLDs were in closer agreement with each other, while alanine provided the closest match between the expected and measured dose, with certain caveats related to absolute reference dose. CONCLUSION: In conclusion, successful cross-validation of different electron beams operating under different energies and configurations lays the foundation for establishing dosimetric consensus for UHDR irradiation studies, and, if widely implemented, decrease uncertainty between different sites investigating the mechanistic basis of the FLASH effect.


Assuntos
Elétrons , Radiometria , Humanos , Imagens de Fantasmas , Água , Alanina
17.
Pract Radiat Oncol ; 12(3): 245-258, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35182803

RESUMO

PURPOSE: In this article, we describe the technical aspects of the Stanford volumetric modulated arc therapy (VMAT) total body irradiation (TBI) technique, compare it with other VMAT-TBI techniques, and share our initial experience. METHODS AND MATERIALS: From September 2019 to August 2021, 35 patients were treated with VMAT-TBI at our institution. Treatment planning was performed using in-house developed automated planning scripts. Organ sparing depended on the regimen: myeloablative (lungs, kidneys, and lenses) and nonmyeloablative with benign disease (lungs, kidneys, lenses, gonads, brain, and thyroid). Quality assurance was performed using electronic portal imaging device portal dosimetry and Mobius3D. Robustness was evaluated for the first 10 patients by performing local and global isocenter shifts of 5 mm. Treatment was delivered using image-guided radiation therapy for every isocenter and every fraction. In vivo measurements were performed on the match line between the VMAT and anterior-posterior/posterior-anterior fields and on the testes for the first fraction. RESULTS: The lungs, lungs - 1 cm, and kidneys Dmean were consistently spared to 57.6% ± 4.4%, 40.7% ± 5.5%, and 70.0% ± 9.9% of the prescription dose, respectively. Gonadal sparing (Dmean = 0.69 ± 0.13 Gy) was performed for all patients with benign disease. The average planning target volume (PTV) maximum dose to 1 cubic centimeter (D1cc) was 120.7% ± 6.4% for all patients. The average Gamma passing rate for the VMAT plans was 98.1% ± 1.6% (criterion of 3%/2 mm). Minimal differences were observed between Mobius3D- and Eclipse AAA-calculated PTV Dmean (0.0% ± 0.3%) and lungs Dmean (-2.5% ± 1.2%). Robustness evaluation showed that the PTV Dmax and lungs Dmean were insensitive to small positioning deviations between the VMAT isocenters (1.1% ± 2.4% and 1.2% ± 1.0%, respectively). The average match-line dose measurement indicated patient setup was reproducible (96.1% ± 4.5% relative to prescription dose). Treatment time, including patient setup and beam-on, was 47.5 ± 9.5 min. CONCLUSIONS: The Stanford VMAT-TBI technique, from simulation to treatment delivery, was presented and compared with other VMAT-TBI techniques. Together with publicly shared autoplanning scripts, our technique may provide the gateway for wider adaptation of this technology and the possibility of multi-institutional studies in the cooperative group setting.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Irradiação Corporal Total/métodos
18.
Pract Radiat Oncol ; 12(3): e216-e220, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34971793

RESUMO

PURPOSE: Radiation therapy (RT) is essential to managing many pediatric malignancies but can provoke anxiety, fear, and discomfort for children owing to prolonged treatment time, extended course, and restrictive immobilization. Patients younger than 10 years frequently require daily general anesthesia (GA), which is resource intensive, expensive, potentially toxic, and anxiety and fear provoking. Audio-Visual Assisted Therapeutic Ambience in Radiation Therapy (AVATAR), a video streaming device, has been proposed as an alternative to anesthesia in patients aged 3 to 10 years. A pilot study evaluating the efficacy of this novel innovation is accruing, but patients younger than 3 years are ineligible. METHODS AND MATERIALS: We simulated a 2-year-old with stage IV Wilms tumor for bilateral whole-lung and left-flank irradiation without GA. Using AVATAR, we attempted to deliver RT to this patient without sedation. Patient anxiety at the time of simulation and at the beginning, middle, and end of the treatment course was characterized using the validated Modified Yale Preoperative Anxiety Score (mYPAS) measurement tool. RESULTS: Although the patient tolerated computed tomography simulation without GA or AVATAR use, his mYPAS of 14 out of 18 indicated significant anxiety. Using AVATAR, all treatments were delivered without GA; his mYPASs were 5 and 4 (the lowest possible) and 4 at the first, midcourse, and final treatments, indicating no significant anxiety and a decrease from the pre-AVATAR baseline. Without GA, the time to deliver RT decreased by 66% from 90 to 30 minutes. CONCLUSIONS: We describe an expanded, previously unreported indication for AVATAR by demonstrating the feasibility of this approach to reduce or omit anesthesia in appropriate younger patients currently excluded from ongoing trials. The financial and quality-of-life benefits (including decreased stress, anxiety, toxic effects, cost, and appointment time) of AVATAR use may be extendable to a younger patient population than previously thought. In older children, prospective validation is ongoing, but additional study in patients younger than 3 years is needed.


Assuntos
Ansiedade , Neoplasias , Anestesia Geral , Ansiedade/etiologia , Criança , Pré-Escolar , Humanos , Neoplasias/radioterapia , Projetos Piloto , Cuidados Pré-Operatórios
19.
J Appl Clin Med Phys ; 22(10): 73-81, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34480841

RESUMO

PURPOSE: The goal of this work was to develop and test nontoxic electron collimation technologies for clinical use. METHODS: Two novel technologies were investigated: tungsten-silicone composite and 3D printed electron cutouts. Transmission, dose uniformity, and profiles were measured for the tungsten-silicone. Surface dose, relative dose output, and field size were measured for the 3D printed cutouts and compared with the standard cerrobend cutouts in current clinical use. Quality assurance tests including mass measurements, Megavoltage (MV) imaging, and drop testing were developed for the 3D printed cutouts as a guide to safe clinical implementation. RESULTS: Dose profiles of the flexible tungsten-silicone skin shields had an 80-20 penumbra values of 2-3 mm compared to 7-8 mm for cerrobend. In MV transmission image measurements of the tungsten-silicone, 80% of the pixels had a transmission value within 2% of the mean. An ∼90% reduction in electron intensity was measured for 6 MeV and a 6.4 mm thickness of tungsten-silicone and 12.7 mm thickness for 16 MeV. The maximum difference in 3D printed cutout versus cerrobend output, surface dose, and full width at half-maximum (FWHM) was 1.7%, 1.2%, and 1.5%, respectively, for the 10 cm × 10 cm cutouts. CONCLUSIONS: Both flexible tungsten-silicone and 3D printed cutouts were found to be feasible for clinical use. The flexible tungsten-silicone was of adequate density, flexibility, and uniformity to serve as skin shields for electron therapy. The 3D printed cutouts were dosimetrically equivalent to standard cerrobend cutouts and were robust enough for handling in the clinical environment.


Assuntos
Elétrons , Planejamento da Radioterapia Assistida por Computador , Humanos , Cintilografia , Tungstênio
20.
J Appl Clin Med Phys ; 22(7): 128-136, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34042253

RESUMO

PURPOSE: Electron radiation therapy dose distributions are affected by irregular body surface contours. This study investigates the feasibility of three-dimensional (3D) cameras to substitute for the treatment planning computerized tomography (CT) scan by capturing the body surfaces to be treated for accurate electron beam dosimetry. METHODS: Dosimetry was compared for six electron beam treatments to the nose, toe, eye, and scalp using full CT scan, CT scan with Hounsfield Unit (HU) overridden to water (mimic 3D camera cases), and flat-phantom techniques. Radiation dose was prescribed to a depth on the central axis per physician's order, and the monitor units (MUs) were calculated. The 3D camera spatial accuracy was evaluated by comparing the 3D surface of a head phantom captured by a 3D camera and that generated with the CT scan in the treatment planning system. A clinical case is presented, and MUs were calculated using the 3D camera body contour with HU overridden to water. RESULTS: Across six cases the average change in MUs between the full CT and the 3Dwater (CT scan with HU overridden to water) calculations was 1.3% with a standard deviation of 1.0%. The corresponding hotspots had a mean difference of 0.4% and a standard deviation of 1.9%. The 3D camera captured surface of a head phantom was found to have a 0.59 mm standard deviation from the surface derived from the CT scan. In-vivo dose measurements (213 ± 8 cGy) agreed with the 3D-camera planned dose of 209 ± 6 cGy, compared to 192 ± 6 cGy for the flat-phantom calculation (same MUs). CONCLUSIONS: Electron beam dosimetry is affected by irregular body surfaces. 3D cameras can capture irregular body contours which allow accurate dosimetry of electron beam treatment as an alternative to costly CT scans with no extra exposure to radiation. Tools and workflow for clinical implementation are provided.


Assuntos
Elétrons , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA