Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Radiother Oncol ; 190: 110042, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38043902

RESUMO

The results of phase II and III trials on Stereotactic Body Radiation Therapy (SBRT) increased adoption of SBRT worldwide. The ability to replicate clinical trial outcomes in routine practice depends on the capability to reproduce technical and dosimetric procedures used in the clinical trial. In this systematic review, we evaluated if peer-reviewed publications of clinical trials in SBRT reported sufficient technical data to ensure safe and robust implementation in real world clinics. Twenty papers were selected for inclusion, and data was extracted by a working group of medical physicists created following the ESTRO 2021 physics workshop. A large variability in technical and dosimetric data were observed, with frequent lack of required information for reproducing trial procedures. None of the evaluated studies were judged completely reproducible from a technical perspective. A list of recommendations has been provided by the group, based on the analysis and consensus process, to ensure an adequate reproducibility of technical parameters in primary SBRT clinical trials. Future publications should consider these recommendations to assist transferability of the clinical trial in real world practice.


Assuntos
Radiocirurgia , Humanos , Radiocirurgia/métodos , Reprodutibilidade dos Testes , Radiometria , Planejamento da Radioterapia Assistida por Computador/métodos
2.
Radiother Oncol ; 171: 121-128, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35461949

RESUMO

BACKGROUND: The quality of radiotherapy delivery has been shown to significantly impact clinical outcomes including patient survival. To identify errors, institutions perform Patient Specific Quality Assurance (PSQA) assessing each individual radiotherapy plan prior to starting patient treatments. Externally administered Dosimetry Audits have found problems despite institutions passing their own PSQA. Hence a new audit concept which assesses the institution's ability to detect errors with their routine PSQA is needed. METHODS: Purposefully introduced edits which simulated treatment delivery errors were embedded into radiation treatment plans of participating institutions. These were designed to produce clinically significant changes yet were mostly within treatment delivery specifications. Actual impact was centrally assessed for each plan. Institutions performed PSQA on each plan, without knowing which contained errors. RESULTS: Seventeen institutions using six radiation treatment planning systems and two delivery systems performed PSQA on twelve plans each. Seventeen erroneous plans (across seven institutions) passed PSQA despite causing >5% increase in spinal cord dose relative to the original plans. Six plans (from four institutions) passed despite a >10% increase. CONCLUSIONS: This novel audit concept evolves beyond testing an institution's ability to deliver a single test case, to increasing the number of errors caught by institutions themselves, thus increasing quality of radiation therapy and impacting every patient treated. Administered remotely this audit also provides advantages in cost, environmental impact, and logistics.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Ensaios Clínicos como Assunto , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Radiometria , Dosagem Radioterapêutica
3.
Radiother Oncol ; 158: 97-103, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33636231

RESUMO

PURPOSE/OBJECTIVE: Total body irradiation (TBI) remains a key component of conditioning for allogeneic haemopoietic stem cell transplant (HSCT), with interstitial pneumonitis (IP) and chronic kidney disease (CKD) important late sequelae. We undertook a retrospective service evaluation of TBI patients treated with a forward-planned intensity modulated radiotherapy technique (FP IMRT). MATERIAL/METHODS: 74 adult patients were identified; all received step and shoot FP IMRT TBI, 14.4 Gy in 8 fractions over 4 days. Mean doses to the lungs and kidneys were 12-12.5 Gy. Toxicities were defined as per CTCAE v4.0: IP as multilobar infiltrates on CT with symptoms of dyspnoea, and renal dysfunction as an Estimated Glomerular Filtration rate (eGFR) < 60 ml/min/1.73 m2 for > 3 months. Secondary endpoints were overall survival (OS), progression free survival (PFS), cumulative incidence of non-relapse mortality (NRM), relapse risk and of acute and chronic GvHD. RESULTS: Patients received treatment for the following diagnosis: ALL/LBL (n = 37); AML (n = 33), CML-BC (n = 2) and High grade NHL (n = 2). The rate of IP due to any cause was 30%; positive microbiological evidence in 73% (16 /22). Idiopathic IP was seen in 8%, with only 4% (n = 3) having IP Grade ≥ 3. Two (4%) of 52 long term survivors developed CKD, one with thrombotic microangiopathy. 4 year NRM was 16% (CI 11-32%); no treatment related deaths in matched sibling or umbilical cord blood HSCT. CONCLUSION: FP IMRT TBI, reducing dose to the lungs and kidneys, has lower rates of idiopathic IP and CKD compared to the literature. This technique is safe and effective conditioning for full intensity HSCT.


Assuntos
Doença Enxerto-Hospedeiro , Transplante de Células-Tronco Hematopoéticas , Doenças Pulmonares Intersticiais , Radioterapia de Intensidade Modulada , Insuficiência Renal Crônica , Adulto , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Humanos , Incidência , Doenças Pulmonares Intersticiais/epidemiologia , Doenças Pulmonares Intersticiais/etiologia , Radioterapia de Intensidade Modulada/efeitos adversos , Estudos Retrospectivos , Condicionamento Pré-Transplante/efeitos adversos , Transplante Homólogo , Irradiação Corporal Total/efeitos adversos
4.
Phys Med Biol ; 64(8): 08NT01, 2019 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-30808011

RESUMO

Radiotherapy treatment plans using dynamic couch rotation during volumetric modulated arc therapy (DCR-VMAT) reduce the dose to organs at risk (OARs) compared to coplanar VMAT, while maintaining the dose to the planning target volume (PTV). This paper seeks to validate this finding with measurements. DCR-VMAT treatment plans were produced for five patients with primary brain tumours and delivered using a commercial linear accelerator (linac). Dosimetric accuracy was assessed using point dose and radiochromic film measurements. Linac-recorded mechanical errors were assessed by extracting deviations from log files for multi-leaf collimator (MLC), couch, and gantry positions every 20 ms. Dose distributions, reconstructed from every fifth log file sample, were calculated and used to determine deviations from the treatment plans. Median (range) treatment delivery times were 125 s (123-133 s) for DCR-VMAT, compared to 78 s (64-130 s) for coplanar VMAT. Absolute point doses were 0.8% (0.6%-1.7%) higher than prediction. For coronal and sagittal films, respectively, 99.2% (96.7%-100%) and 98.1% (92.9%-99.0%) of pixels above a 20% low dose threshold reported gamma <1 for 3% and 3 mm criteria. Log file analysis showed similar gantry rotation root-mean-square error (RMSE) for VMAT and DCR-VMAT. Couch rotation RMSE for DCR-VMAT was 0.091° (0.086-0.102°). For delivered dose reconstructions, 100% of pixels above a 5% low dose threshold reported gamma <1 for 2% and 2 mm criteria in all cases. DCR-VMAT, for the primary brain tumour cases studied, can be delivered accurately using a commercial linac.


Assuntos
Neoplasias Encefálicas/radioterapia , Posicionamento do Paciente/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Humanos , Órgãos em Risco , Aceleradores de Partículas , Posicionamento do Paciente/normas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/normas , Rotação
5.
Br J Radiol ; 92(1097): 20180908, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30694086

RESUMO

This paper gives an overview of recent developments in non-coplanar intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Modern linear accelerators are capable of automating motion around multiple axes, allowing efficient delivery of highly non-coplanar radiotherapy techniques. Novel techniques developed for C-arm and non-standard linac geometries, methods of optimization, and clinical applications are reviewed. The additional degrees of freedom are shown to increase the therapeutic ratio, either through dose escalation to the target or dose reduction to functionally important organs at risk, by multiple research groups. Although significant work is still needed to translate these new non-coplanar radiotherapy techniques into the clinic, clinical implementation should be prioritized. Recent developments in non-coplanar radiotherapy demonstrate that it continues to have a place in modern cancer treatment.


Assuntos
Neoplasias/radioterapia , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Órgãos em Risco , Aceleradores de Partículas , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos
6.
Acta Oncol ; 57(9): 1240-1249, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29698060

RESUMO

PURPOSE: Conventional techniques (3D-CRT) for craniospinal irradiation (CSI) are still widely used. Modern techniques (IMRT, VMAT, TomoTherapy®, proton pencil beam scanning [PBS]) are applied in a limited number of centers. For a 14-year-old patient, we aimed to compare dose distributions of five CSI techniques applied across Europe and generated according to the participating institute protocols, therefore representing daily practice. MATERIAL AND METHODS: A multicenter (n = 15) dosimetric analysis of five different techniques for CSI (3D-CRT, IMRT, VMAT, TomoTherapy®, PBS; 3 centers per technique) was performed using the same patient data, set of delineations and dose prescription (36.0/1.8 Gy). Different treatment plans were optimized based on the same planning target volume margin. All participating institutes returned their best treatment plan applicable in clinic. RESULTS: The modern radiotherapy techniques investigated resulted in superior conformity/homogeneity-indices (CI/HI), particularly in the spinal part of the target (CI: 3D-CRT:0.3 vs. modern:0.6; HI: 3D-CRT:0.2 vs. modern:0.1), and demonstrated a decreased dose to the thyroid, heart, esophagus and pancreas. Dose reductions of >10.0 Gy were observed with PBS compared to modern photon techniques for parotid glands, thyroid and pancreas. Following this technique, a wide range in dosimetry among centers using the same technique was observed (e.g., thyroid mean dose: VMAT: 5.6-24.6 Gy; PBS: 0.3-10.1 Gy). CONCLUSIONS: The investigated modern radiotherapy techniques demonstrate superior dosimetric results compared to 3D-CRT. The lowest mean dose for organs at risk is obtained with proton therapy. However, for a large number of organs ranges in mean doses were wide and overlapping between techniques making it difficult to recommend one radiotherapy technique over another.


Assuntos
Radiação Cranioespinal/métodos , Padrões de Prática Médica/estatística & dados numéricos , Radioterapia (Especialidade) , Adolescente , Comitês Consultivos/organização & administração , Radiação Cranioespinal/estatística & dados numéricos , Europa (Continente)/epidemiologia , Humanos , Masculino , Órgãos em Risco/efeitos da radiação , Radioterapia (Especialidade)/métodos , Radioterapia (Especialidade)/organização & administração , Radiometria/métodos , Radiometria/normas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas
7.
Radiother Oncol ; 121(1): 124-131, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27481571

RESUMO

BACKGROUND AND PURPOSE: To evaluate non-coplanar volumetric modulated arc radiotherapy (VMAT) trajectories for organ at risk (OAR) sparing in primary brain tumor radiotherapy. MATERIALS AND METHODS: Fifteen patients were planned using coplanar VMAT and compared against non-coplanar VMAT plans for three trajectory optimization techniques. A geometric heuristic technique (GH) combined beam scoring and Dijkstra's algorithm to minimize the importance-weighted sum of OAR volumes irradiated. Fluence optimization was used to perform a local search around coplanar and GH trajectories, producing fluence-based local search (FBLS) and FBLS+GH trajectories respectively. RESULTS: GH, FBLS, and FBLS+GH trajectories reduced doses to the contralateral globe, optic nerve, hippocampus, temporal lobe, and cochlea. However, FBLS increased dose to the ipsilateral lens, optic nerve and globe. Compared to GH, FBLS+GH increased dose to the ipsilateral temporal lobe and hippocampus, contralateral optics, and the brainstem and body. GH and FBLS+GH trajectories reduced bilateral hippocampi normal tissue complication probability (p=0.028 and p=0.043, respectively). All techniques reduced PTV conformity; GH and FBLS+GH trajectories reduced homogeneity but less so for FBLS+GH. CONCLUSIONS: The geometric heuristic technique best spared OARs and reduced normal tissue complication probability, however incorporating fluence information into non-coplanar trajectory optimization maintained PTV homogeneity.


Assuntos
Neoplasias Encefálicas/radioterapia , Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Neoplasias Encefálicas/diagnóstico por imagem , Humanos , Modelos Biológicos , Órgãos em Risco/diagnóstico por imagem , Probabilidade , Dosagem Radioterapêutica
8.
Radiother Oncol ; 120(2): 320-6, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27470308

RESUMO

BACKGROUND AND PURPOSE: Delivering selected parts of volumetric modulated arc therapy (VMAT) plans using step-and-shoot intensity modulated radiotherapy (IMRT) beams has the potential to increase plan quality by allowing specific aperture positioning. This study investigates the quality of treatment plans and the accuracy of in vivo portal dosimetry in such a hybrid approach for the case of prostate radiotherapy. MATERIAL AND METHODS: Conformal and limited-modulation VMAT plans were produced, together with five hybrid IMRT/VMAT plans, in which 0%, 25%, 50%, 75% or 100% of the segments were sequenced for IMRT, while the remainder were sequenced for VMAT. Integrated portal images were predicted for the plans. The plans were then delivered as a single hybrid beam using an Elekta Synergy accelerator with Agility head to a water-equivalent phantom and treatment time, isocentric dose and portal images were measured. RESULTS: Increasing the IMRT percentage improves dose uniformity to the planning target volume (p<0.01 for 50% IMRT or more), substantially reduces the volume of rectum irradiated to 65Gy (p=0.02 for 25% IMRT) and increases the monitor units (p<0.001). Delivery time also increases substantially. All plans show accurate delivery of dose and reliable prediction of portal images. CONCLUSIONS: Hybrid IMRT/VMAT can be efficiently planned and delivered as a single beam sequence. Beyond 25% IMRT, the delivery time becomes unacceptably long, with increased risk of intrafraction motion, but 25% IMRT is an attractive compromise. Integrated portal images can be used to perform in vivo dosimetry for this technique.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Dosimetria in Vivo , Fígado/efeitos da radiação , Masculino , Posicionamento do Paciente , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/métodos , Reto/efeitos da radiação , Estudos Retrospectivos
9.
Phys Med Biol ; 58(22): 8163-77, 2013 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-24200876

RESUMO

Non-coplanar radiation beams are often used in three-dimensional conformal and intensity modulated radiotherapy to reduce dose to organs at risk (OAR) by geometric avoidance. In volumetric modulated arc radiotherapy (VMAT) non-coplanar geometries are generally achieved by applying patient couch rotations to single or multiple full or partial arcs. This paper presents a trajectory optimization method for a non-coplanar technique, dynamic couch rotation during VMAT (DCR­VMAT), which combines ray tracing with a graph search algorithm. Four clinical test cases (partial breast, brain, prostate only, and prostate and pelvic nodes) were used to evaluate the potential OAR sparing for trajectory-optimized DCR­VMAT plans, compared with standard coplanar VMAT. In each case, ray tracing was performed and a cost map reflecting the number of OAR voxels intersected for each potential source position was generated. The least-cost path through the cost map, corresponding to an optimal DCR­VMAT trajectory, was determined using Dijkstra's algorithm. Results show that trajectory optimization can reduce dose to specified OARs for plans otherwise comparable to conventional coplanar VMAT techniques. For the partial breast case, the mean heart dose was reduced by 53%. In the brain case, the maximum lens doses were reduced by 61% (left) and 77% (right) and the globes by 37% (left) and 40% (right). Bowel mean dose was reduced by 15% in the prostate only case. For the prostate and pelvic nodes case, the bowel V50 Gy and V60 Gy were reduced by 9% and 45% respectively. Future work will involve further development of the algorithm and assessment of its performance over a larger number of cases in site-specific cohorts.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Rotação , Algoritmos , Humanos , Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Radioterapia de Intensidade Modulada/efeitos adversos
10.
J Appl Clin Med Phys ; 14(2): 4136, 2013 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-23470941

RESUMO

The Agility multileaf collimator (Elekta AB, Stockholm, Sweden) has 160 leaves of projected width 0.5 cm at the isocenter, with maximum leaf speed 3.5 cms-1. These characteristics promise to facilitate fast and accurate delivery of radiotherapy, particularly volumetric-modulated arc therapy (VMAT). The aim of this study is therefore to create a beam model for the Pinnacle3 treatment planning system (Philips Radiation Oncology Systems, Fitchburg, WI), and to use this beam model to explore the performance of the Agility MLC in delivery of VMAT. A 6 MV beam model was created and verified by measuring doses under irregularly shaped fields. VMAT treatment plans for five typical head-and-neck patients were created using the beam model and delivered using both binned and continuously variable dose rate (CVDR). Results were compared with those for an MLCi unit without CVDR. The beam model has similar parameters to those of an MLCi model, with interleaf leakage of only 0.2%. The verification of irregular fields shows a mean agreement between measured and planned dose of 1.3% (planned dose higher). The Agility VMAT head-and-neck plans show equivalent plan quality and delivery accuracy to those for an MLCi unit, with 95% of verification measurements within 3% and 3 mm of planned dose. Mean delivery time is 133 s with the Agility head and CVDR, 171 s without CVDR, and 282 s with an MLCi unit. Pinnacle3 has therefore been shown to model the Agility MLC accurately, and to provide accurate VMAT treatment plans which can be delivered significantly faster with Agility than with an MLCi.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Radiometria/instrumentação , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA