Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ind Eng Chem Res ; 62(49): 21152-21163, 2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38107750

RESUMO

Despite offering low-carbon and reliable energy, the utilization of nuclear energy is declining globally due to high upfront capital costs and longer returns on investments. Nuclear cogeneration of valuable chemicals from waste biomass-derived feedstocks could have beneficial impacts while harnessing the underutilized resource of ionizing energy. Here, we demonstrate selective methanol or acetaldehyde production from ethylene glycol, a feedstock derived from glycerol, a byproduct of biodiesel, using irradiations from a nuclear fission reactor. The influence of radiation quality, dose rate, and the absorbed dose of irradiations on radiochemical yields (G-value) has been studied. Under low-dose-rate, γ-only radiolysis during reactor shutdown rate (<0.018 kGy min-1), acetaldehyde is produced at a maximum G-value of 8.28 ± 1.05 µmol J-1 and a mass productivity of 0.73 ± 0.06% from the 20 kGy irradiation of neat ethylene glycol. When exposed to a high-dose-rate (6.5 kGy min-1), 100 kGy mixed-field of neutron + γ-ray radiations, the radiolytic selectivity is adjusted from acetaldehyde to generate methanol at a G-value of 2.91 ± 0.78 µmol J-1 and a mass productivity of 0.93 ± 0.23%. Notably, utilizing 422 theoretical systems could contribute to 4.96% of worldwide acetaldehyde production using a spent fuel pool γ-ray scheme. This research reports G-values and production capacities for acetaldehyde for high-dose scenarios and shows the potential selectivity of a nuclear cogeneration process to synthesize chemicals based on their irradiation conditions from the same reagent.

2.
Materials (Basel) ; 16(6)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36984081

RESUMO

We report on the effects of large-area 4H-SiC Schottky barrier diodes on the radiation response to ionizing particles. Two different diode areas were compared: 1 mm × 1 mm and 5 mm × 5 mm. 6LiF and 10B4C films, which were placed on top of the diodes, were used as thermal neutron converters. We achieved a thermal neutron efficiency of 5.02% with a 6LiF thermal neutron converter, which is one of the highest efficiencies reported to date. In addition, a temperature-dependent radiation response to alpha particles was presented. Neutron irradiations were performed in a JSI TRIGA dry chamber and an Am-241 wide-area alpha source was used for testing the alpha response of the 4H-SiC Schottky barrier diodes.

3.
Radiol Oncol ; 56(2): 248-258, 2022 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-35575586

RESUMO

INTRODUCTION: Potential changes in patient anatomy during proton radiotherapy may lead to a deviation of the delivered dose. A dose estimate can be computed through a deformable image registration (DIR) driven dose accumulation. The present study evaluates the accumulated dose uncertainties in a patient subject to an inadvertent breathing associated motion. MATERIALS AND METHODS: A virtual lung tumour was inserted into a pair of single participant landmark annotated computed tomography images depicting opposite breathing phases, with the deep inspiration breath-hold the planning reference and the exhale the off-reference geometry. A novel Monte Carlo N-Particle, Version 6 (MCNP6) dose engine was developed, validated and used in treatment plan optimization. Three DIR methods were compared and used to transfer the exhale simulated dose to the reference geometry. Dose conformity and homogeneity measures from International Committee on Radioactivity Units and Measurements (ICRU) reports 78 and 83 were evaluated on simulated dose distributions registered with different DIR algorithms. RESULTS: The MCNP6 dose engine handled patient-like geometries in reasonable dose calculation times. All registration methods were able to align image associated landmarks to distances, comparable to voxel sizes. A moderate deterioration of ICRU measures was encountered in comparing doses in on and off-reference anatomy. There were statistically significant DIR driven differences in ICRU measures, particularly a 10% difference in the relative D98% for planning tumour volume and in the 3 mm/3% gamma passing rate. CONCLUSIONS: T he dose accumulation over two anatomies resulted in a DIR driven uncertainty, important in reporting the associated ICRU measures for quality assurance.


Assuntos
Neoplasias Pulmonares , Planejamento da Radioterapia Assistida por Computador , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
4.
Sci Rep ; 11(1): 13975, 2021 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-34234238

RESUMO

Collection and interpolation of radiation observations is of vital importance to support routine operations in the nuclear sector globally, as well as for completing surveys during crisis response. To reduce exposure to ionizing radiation that human workers can be subjected to during such surveys, there is a strong desire to utilise robotic systems. Previous approaches to interpolate measurements taken from nuclear facilities to reconstruct radiological maps of an environment cannot be applied accurately to data collected from a robotic survey as they are unable to cope well with irregularly spaced, noisy, low count data. In this work, a novel approach to interpolating radiation measurements collected from a robot is proposed that overcomes the problems associated with sparse and noisy measurements. The proposed method integrates an appropriate kernel, benchmarked against the radiation transport code MCNP6, into the Gaussian Process Regression technique. The suitability of the proposed technique is demonstrated through its application to data collected from a bespoke robotic system used to conduct a survey of the Joz̆ef Stefan Institute TRIGA Mark II nuclear reactor during steady state operation, where it is shown to successfully reconstruct gamma dosimetry estimates in the reactor hall and aid in identifying sources of ionizing radiation.

5.
J Memb Sci ; 619: 118756, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33024349

RESUMO

Ionizing radiation has been identified as an option for sterilization of disposable filtering facepiece respirators in situations where the production of the respirators cannot keep up with demand. Gamma radiation and high energy electrons penetrate deeply into the material and can be used to sterilize large batches of masks within a short time period. In relation to reports that sterilization by ionizing radiation reduces filtration efficiency of polypropylene membrane filters on account of static charge loss, we have demonstrated that both gamma and electron beam irradiation can be used for sterilization, provided that the respirators are recharged afterwards.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA