Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Thorac Cardiovasc Surg ; 72(3): 188-196, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36858066

RESUMO

BACKGROUND: Bioprosthetic stentless aortic valves may degenerate over time and will require replacement. This study aimed to evaluate early- and mid-term outcomes after isolated surgical redo aortic valve replacement (redo-SAVR) and transcatheter valve-in-valve implantation (TAVI-VIV) for degenerated stentless Freestyle bioprostheses. METHODS: We reviewed records of 56 patients at a single center. Overall, 37 patients (66.1%) received TAVI-VIV and 19 (33.9%) received redo-SAVR. RESULTS: Thirty-day survival was similar in both groups (100%). One-year survival was comparable between groups (97.3% in TAVI-VIV and 100% in redo-SAVR, p = 1.0). The difference in mid-term survival after adjusting for age and EuroScore II was not significant (p = 0.41). The incidence of pacemaker implantation after TAVI-VIV was higher than after redo-SAVR (19.4% vs. 0%, p = 0.08). CONCLUSION: The 30-day and 1-year survival rates after both procedures were outstanding, irrespective of baseline characteristics. Isolated redo-SAVR should be favored in young patients, as the pacemaker implantation rate is lower. TAVI-VIV for degenerated Freestyle prosthesis can be a method of choice in elderly patients and those with high operative risk.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese , Reoperação/métodos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Artigo em Inglês | MEDLINE | ID: mdl-36088142

RESUMO

OBJECTIVES: Degeneration of mitral prostheses/rings may be treated by redo surgery, and, recently, by transcatheter valve-in-valve/ring implantation. This multicenter registry presents results of transcatheter valve-in-valve and repeat surgery for prostheses/rings degeneration. METHODS: Data provided by 10 German heart centers underwent propensity score-matched retrospective analysis. The primary endpoint was 30-day/midterm mortality. Perioperative outcome was assessed according to the Mitral Valve Academic Research Consortium criteria. Further, the influence of moderate or greater tricuspid regurgitation (TR) on 30-day/midterm mortality was analyzed. RESULTS: Between 2014 and 2019, 273 patients (79 transcatheter mitral valve-in-valve [TM-ViV] and 194 redo mitral valve replacement [Re-MVR]) underwent repeat procedure for mitral prosthesis/ring degeneration. Propensity score matching distinguished 79 patient pairs. European System for Cardiac Operative Risk Evaluation (EuroSCORE) II-predicted risk was 15.7 ± 13.7% in the TM-ViV group and 15.0% ± 12.7% in the Re-MVR group (P = .5336). TM-ViV patients were older (74.73 vs 72.2 years; P = .0030) and had higher incidence of atrial fibrillation (54 vs 40 patients; P = .0233). Severe TR incidence was similar (17.95% in TM-ViV vs 14.10%; P = .1741). Sixty-eight TM-ViV patients previously underwent mitral valve replacement, whereas 41 Re-MVR patients underwent valve repair (P < .0001). Stenosis was the leading degeneration mechanism in 42 TM-ViV versus 22 Re-MVR patients (P < .0005). The 30-day/midterm mortality did not differ between groups. Moderate or greater TR was a predictor of total (odds ratio [OR], 4.36; P = .0011), 30-day (OR, 3.76; P = .0180), and midterm mortality (OR, 4.30; P = .0378), irrespective of group. CONCLUSIONS: In both groups, observed mortality was less than predicted. Redo surgery enabled treatment of concomitant conditions, such as atrial fibrillation or TR. TR was shown to be a predictor of total, 30-day, and midterm mortality in both groups.

3.
Eur J Cardiothorac Surg ; 60(5): 1234-1236, 2021 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-34113958

RESUMO

A 73-year-old patient who underwent an emergency coronary bypass surgery in our institution and who required postoperative extracorporeal membrane oxygenation support in December 2019 presented in August 2020 with a rapidly growing subxiphoidal, pulsating swelling. A computed tomography scan revealed a massive mediastinal pseudoaneurysm originating from an 8-mm Dacron graft that was sutured to the ascending aorta during the index surgery for arterial extracorporeal membrane oxygenation cannulation. Due to the location and extent of the pseudoaneurysm, an open surgical revision was deemed high risk. Because no bypass conduit originated from the ascending aorta, we decided to occlude the entry of the pseudoaneurysm with a stent graft. Also, urgency did not allow for the manufacturing of a custom-made device, so an off-the-shelf stent graft had to be implanted. Currently, the only off-the-shelf thoracic stent graft with a length suitable for the ascending aorta (<7 cm) is the Medtronic Valiant Navion prosthesis, of which 2 prostheses (37 mm × 52 mm; covered seal) were successfully implanted to exclude the pseudoaneurysm. A follow-up computed tomography scan performed 4 months postoperatively showed no perfusion and regression of the pseudoaneurysm. With the growing number of reports describing stent graft placement in the ascending aorta, more off-the-shelf stent grafts suitable for the ascending aorta are desirable.


Assuntos
Falso Aneurisma , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Aorta/diagnóstico por imagem , Aorta/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Humanos , Stents , Resultado do Tratamento
4.
Thorac Cardiovasc Surg Rep ; 10(1): e22-e24, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33758741

RESUMO

Background Although surgical closure of ventricular septal defect (VSD) is the gold standard treatment, patients are subjected to deterioration in the following decades. We will present here the first case in literature surviving 60 years after surgical VSD closure with a residual VSD and presenting again for surgery. Case Description A 68-year-old male patient who underwent surgical closure of a perimembranous VSD in Berlin in 1959. Postoperatively, a small residual VSD was noticed, which was well tolerated over six decades. He presented 60 years postoperatively with severe aortic regurgitation, tricuspid regurgitation, and moderate mitral regurgitation.

5.
Interact Cardiovasc Thorac Surg ; 32(5): 724-726, 2021 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-33647986

RESUMO

The objective of this study was to evaluate the use of the generation of 3D models and 3D prints of complex cases for physicians at the example of an intricate left ventricular outflow tract obstruction (LVOTO). LVOTO is a known complication of mitral valve surgery. A 38-year-old female patient with increasing dyspnoea after mitral valve replacement was referred to our centre. Echocardiography showed a strut of the bioprosthetic heart valve protruding into the left ventricular outflow tract. However, the diagnosis of a LVOTO was difficult based on echocardiography alone. Therefore, we fabricated a physical model of the left ventricular outflow tract, the mitral valve, the aortic valve and the left ventricle. With this physical model in hand, we were able to visualize the LVOTO and to discuss potential therapeutic options. Moreover, we were able to plan the subsequent redo surgery in detail using the model. This case shows the benefit of 3D printing technologies for surgeons and patients, not only for analysis, but also during the decision-making and pre-operative planning process.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Impressão Tridimensional , Adulto , Feminino , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia
6.
Thorac Cardiovasc Surg ; 69(4): 357-361, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32559811

RESUMO

Thoracic endovascular aortic repair (TEVAR) for aortic pathologies requires sufficient landing zone of ideally more than 25 mm for safe anchoring of the stent-graft and prevention of endoleaks. In the aortic arch and at the thoracoabdominal transition, landing zone length is usually limited by the offspring of the major aortic side-branches. Exact deployment of the stent-graft to effectively use the whole length of the landing zone and to prevent occlusion of one of the side-branches is key to successful TEVAR. There are numerous techniques described to lower blood pressure and to reduce or eliminate aortic impulse to facilitate exact deployment of stent-grafts including pharmacologic blood pressure lowering, adenosine-induced asystole, inflow occlusion, and rapid pacing. Aim of this review was to assess the current literature to identify which of the techniques is best suited to prevent displacement and allow for precise placement of the stent-graft and safe balloon-molding.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Hemodinâmica , Humanos , Desenho de Prótese , Resultado do Tratamento
7.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 2552-2556, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33018527

RESUMO

Mitral valve regurgitation is one of the most common heart valve diseases and mitral valve repair is the favored therapy, in which a part of the mitral valve is resected. To improve preoperative planning of this challenging surgery, patient-specific mitral valve replicas have been developed on which the repair can be simulated. However, there is no possibility yet to transfer the planning from the replica to the surgery of the patient. To solve this problem, we developed a patient-specific instrument with a cutting template, intraoperatively visualizing the part of the mitral valve to be resected as planned on the replica. To realize this instrument, the surgeon first simulates mitral valve repair by resection on a patient-specific mitral valve replica. This postoperative mitral valve replica is then digitalized and from it and a preoperative mitral valve model the instrument with cutting template is automatically designed and then 3D printed. An expert heart surgeon successfully tested the functional principle of the instrument on a pig mitral valve.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Cirurgiões , Animais , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Suínos
8.
Eur J Cardiothorac Surg ; 58(1): 188-189, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32510155

RESUMO

We report on a case of a 57-year-old male patient, who underwent full root replacement in 2005 and now presented with high grade aortic insufficiency. On admission, the patient underwent a computed tomography scan which demonstrated interstitial infiltration in the left lung, highly suspicious for a COVID-19 infection that could not be confirmed by reverse transcription polymerase chain reaction (RT-PCR) testing. As there usually is a delay between infection and positive RT-PCR test results, the initial decision was to perform additional testing. However, the patient deteriorated quickly in spite of optimal medical therapy making urgent aortic valve replacement necessary. We decided to perform transcatheter aortic valve replacement to avoid cardiopulmonary bypass with shorter operative times, presumably shorter ventilation times and duration of intensive care unit stay, and thus a lesser risk for pulmonary complications.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Betacoronavirus , Infecções por Coronavirus/complicações , Pneumonia Viral/complicações , Substituição da Valva Aórtica Transcateter/métodos , Insuficiência da Valva Aórtica/complicações , Betacoronavirus/isolamento & purificação , COVID-19 , Infecções por Coronavirus/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/diagnóstico , SARS-CoV-2
9.
Int J Artif Organs ; : 0, 2017 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-29192716

RESUMO

OBJECTIVES: Cell sources for cardiovascular tissue engineering (TE) are scant. However, the need for an ideal TE cardiovascular implant persists. We investigated the cardiotomy reservoir (CR) as a potential cell source that is more accessible and less ethically problematic. METHODS: CR (n = 10) were removed from the bypass system after surgery. Isolation was performed using different isolation methods: blood samples were taken from the cardiopulmonary bypass and centrifuged at low density. The venous filter screen was cut out and placed into petri dishes for cultivation. The spongelike filter was removed, washed and treated in the same way as the blood samples. After cultivation, cell lines of fibroblasts (FB) and endothelial cells (EC) were obtained for analysis. The cells were seeded on polyurethane patches and analyzed via scanning electron microscopy (SEM), Life/Dead assay and immunohistochemistry. RESULTS: No correlation between age, time of surgery and quality of cells was observed. The successful extraction of FB and was proven by positive staining results for TE-7, CD31 and vWF. Cell morphology, cytoskeleton staining and quantification of proliferation using WST-1 assay resembled the cells of the control group in all ways. The topography of a confluent and vital cell layer after cell seeding was displayed by SEM analysis, Life/Dead Assay and immunohistochemistry. The establishment of an extracellular matrix (ECM) was proven by positive staining for collagen IV, laminin, fibronectin and elastin. CONCLUSIONS: Viable FB and EC cell lines were extracted from the CR after surgery. Easy access and high availability make this cell source destined for widespread application in cardiovascular tissue engineering.

10.
EuroIntervention ; 12(13): 1645-1648, 2017 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-28105997

RESUMO

AIMS: While TAVI is the treatment of choice in patients with aortic stenosis considered inoperable or at high risk, interventional replacement of the mitral valve is still in the preclinical or early clinical phase. Our aim was to report on the first transcatheter double valve replacement into native valves from a transapical access. METHODS AND RESULTS: A 67-year-old, highly symptomatic female patient considered inoperable due to severe calcification of the mitral annulus and comorbidities was scheduled for transcatheter double valve replacement by the local Heart Team. Preoperative planning was carried out by multiplanar reconstruction from cardiac CT. Through a transapical access, the mitral valve was replaced first by an inverted 29 mm Edwards SAPIEN 3 prosthesis, then the aortic valve by a 23 mm SAPIEN 3, both during rapid pacing. Both prostheses revealed excellent function in angiography and echocardiography. The patient was extubated early after surgery and transferred to the normal ward the following day. After five months, she exhibited signs of cardiac failure again. Migration of the mitral prosthesis was detected, and the mitral valve was replaced surgically. CONCLUSIONS: Transcatheter double valve replacement can be performed through a transapical access. The key to success is thorough preoperative planning based on CT, not only for sizing, but also for estimating the anatomical relationship of the prostheses. However, late migration can be expected and may lead to LVOT obstruction.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Próteses Valvulares Cardíacas , Idoso , Estenose da Valva Aórtica/diagnóstico , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Resultado do Tratamento
11.
Heart Surg Forum ; 19(5): E243-E247, 2016 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-27801306

RESUMO

BACKGROUND: The use of bilateral internal mammary arteries (BIMA) is limited worldwide, especially in patients with chronic obstructive pulmonary disease (COPD). Thus, we assessed the safety of the use of BIMA in COPD patients. METHODS: From cohorts of 8846 patients operated on at our center for primary isolated multi-vessel coronary bypass operations between 2002 and 2012, we studied two propensity-matched groups of patients with COPD who received either single internal mammary artery and saphenous vein grafts (SIMA group: 137 patients) or exclusively BIMA (BIMA group: 137 patients). Preoperative data were similar regarding age (63.59 ± 10.62 versus 65.55 ± 9.61 years; P = .10), body mass index (BMI) (28.6 ± 4.71 versus 28.42 ± 3.86 kg/m2; P = .72), diabetes mellitus (32% versus 27%; P = .08), EuroSCORE (4.34 ± 2.23 versus 4.8 ± 2.52; P = .09) and ejection fraction (58.7 ± 13.08% versus 60.29 ± 14.13%; P = .32). RESULTS: No significant differences were noticed between the two groups regarding the number of peripheral anastomoses (3.07 ± 0.77 versus 3.06 ± 0.85; P = .90), total operation time (192.17 ± 43.06 versus 200.63 ± 39.24 min; P = .08), postoperative stroke (0.7% versus 0%; P = .29), myocardial infarction (2.92% versus 3.6%; P = .81), reintubation (2.9% versus 4.4%; P = .66), reexploration (0.7% versus 2.2%; P = .32), deep sternal wound infection (2.9% versus 3.6%; P = .81) and 30-day mortality (2.2% versus 2.9%; P = .77). However, postoperative blood loss (726.1 ± 468.35  versus 907 ± 890.58 mL; P = .03) was higher in the BIMA group. CONCLUSION: COPD patients can benefit from coronary artery revascularization with BIMA; however, postoperative blood loss can be higher using this technique.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Artéria Torácica Interna/transplante , Doença Pulmonar Obstrutiva Crônica/complicações , Veia Safena/transplante , Idoso , Perda Sanguínea Cirúrgica , Ponte de Artéria Coronária/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
12.
Interact Cardiovasc Thorac Surg ; 22(4): 459-63; discussion 463-4, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26792359

RESUMO

OBJECTIVES: End-stage renal disease patients on regular haemodialysis are at higher risk of calcification. Therefore, many surgeons have concerns regarding the implantation of bioprostheses in such patients. The haemodynamic advantages of stentless aortic bioprostheses support their use; however, these have not been studied yet in end-stage renal disease patients. We studied accordingly the early and mid-term outcomes of aortic valve replacement (AVR) using Medtronic Freestyle stentless aortic bioprostheses in this subset of patients in comparison with stented aortic bioprostheses. METHODS: We retrospectively studied two groups of consecutive patients on regular haemodialysis who required AVR between 2007 and 2013. Non-Freestyle (NFS) group received stented aortic bioprostheses (36 patients) and Freestyle (FS) group received Medtronic Freestyle aortic bioprostheses (48 patients). Follow-up ranged from 2 to 76 months with a mean follow-up of 36.3 ± 25 months. RESULTS: Patients in both groups showed similar demographic characters regarding age (76.4 ± 8.1 vs 74.9 ± 7.2 years; P = 0.35), male gender (58 vs 60%; P = 0.57) and diabetes mellitus (42 vs 48%; P = 0.57). Smaller aortic bioprostheses were implanted in the NFS (23.3 ± 1.2 vs 25.4 ± 2.1; P < 0.001) with consequently higher postoperative mean gradients (14.1 ± 4.1 vs 11.9 ± 5.3 mmHg; P = 0.004). No significant differences were noted regarding postoperative neurological disorder (8 vs 12%; P = 0.73), deep sternal wound infection (3 vs 4%; P = 0.68), re-exploration (8 vs 8%; P = 0.91) and in-hospital mortality (6 vs 4%; P = 0.92). Mid-term follow-up showed higher prosthetic valve calcification and/or sclerosis in NFS group (25 vs 6%; P = 0.015), whereas no significant differences were noticed between the two groups regarding stroke (0 vs 8%; P = 0.13), endocarditis (0 vs 4%; P = 0.50), 36- and 72-month survival (51 ± 2%, 14 ± 4% vs 55 ± 2%, 19 ± 3%, respectively; P = 0.45). CONCLUSIONS: Aortic bioprostheses are a good option for haemodialysis patients requiring AVR, offering acceptable mid-term survival. The Medtronic Freestyle aortic bioprostheses could allow the implantation of larger bioprostheses inferring consequently lower mean gradients, with a potentially higher resistance to calcification and sclerosis in haemodialysis patients.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Endocardite/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falência Renal Crônica/terapia , Diálise Renal , Stents , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Endocardite/complicações , Endocardite/diagnóstico , Endocardite/fisiopatologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Desenho de Prótese , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
J Cardiothorac Surg ; 10: 59, 2015 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-25902769

RESUMO

BACKGROUND: In cardiac surgery profuse or persistent sternal bleeding after sternotomy is routinely controlled with bone wax. However, bone wax should be avoided, especially in high-risk patients for nonunion of the sternum and infections. Purpose of this study was to evaluate an alternative technique to control bleeding after medium sternotomy using a plant based absorbable polysaccharide hemostat. METHODS: A consecutive series of 38 patients requiring median sternotomy for coronary artery bypass surgery (21 OPCAB, 17 CABG) had sternal bleeding control with the polysaccharide hemostat, STARSIL® HEMOSTAT. This hemostat is a hydrophilic powder, which achieves hemostasis after topical application at the surgical wound site. Initially it dehydrates blood rapidly, thus accelerating aggregation of platelets and blood solids. Thereafter, it forms a gelled adhesive matrix, which serves as a mechanical barrier against further bleeding. The polysaccharide is completely resorbed within 48 to 72 hours. RESULTS: Satisfactory control of sternal bleeding was observed in 37 patients (97%). No product-related complications were observed or any other major adverse events in an observation period of 3 months. CONCLUSION: Polysaccharide hemostats appear to be safe and effective for bleeding control of the sternum.


Assuntos
Ponte de Artéria Coronária/métodos , Hemorragia/tratamento farmacológico , Hemostasia Cirúrgica/métodos , Hemostáticos/uso terapêutico , Compostos Fitoquímicos/uso terapêutico , Polissacarídeos/uso terapêutico , Esternotomia/métodos , Esterno/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
14.
Eur J Cardiothorac Surg ; 47(6): 1103-4, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25079773

RESUMO

Atrioventricular (AV) disruption is a rare but fatal complication after prosthetic mitral valve replacement. Surgical management is controversial and ranges from epicardial tissue sealing to open repair using autologous or xenogenic patch techniques to autotransplantation of the heart. We report the successful repair of an AV disruption Type I using an extracorporeal life support (ECLS) system for effective ventricular unloading followed by epicardial patch closure. The surgical management of AV disruption benefits from the use of ECLS, as it allows effective decompression of the heart without requiring full heparinization.


Assuntos
Circulação Extracorpórea/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemostasia Cirúrgica/métodos , Insuficiência da Valva Mitral/cirurgia , Idoso , Aprotinina/uso terapêutico , Combinação de Medicamentos , Feminino , Fibrinogênio/uso terapêutico , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/terapia , Humanos , Trombina/uso terapêutico
15.
Eur J Cardiothorac Surg ; 47(6): 1044-52, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25161184

RESUMO

OBJECTIVES: In individual cases, routine preoperative imaging might not be sufficient for optimal planning of cardiovascular procedures. Three-dimensional printing (3D), a widely used technique to build life-like replicas of anatomical structures that has proven value in different medical disciplines, might overcome these shortcomings. However, data on 3D printing in cardiovascular medicine are limited to single reports. This stimulated us to present our single-centre experience with 3D printing models in cardiac surgery and interventional cardiology. METHODS: Between the years 2006 and 2013, we fabricated 3D printing models using preoperative computed tomography or magnetic resonance imaging data in paediatric and adult cardiac surgery, as well as interventional cardiology. We present the 8 most representative cases. RESULTS: The models were very helpful for perioperative planning and orientation, as well as simulation of procedures due to the exact and life-like illustration of the cardiovascular anatomy. CONCLUSIONS: The fabrication of 3D printing models is feasible for perioperative planning and simulation in a variety of complex cases in paediatric and adult cardiac surgery, as well as in interventional cardiology. Further studies including more patients and providing more data are expected to demonstrate that the use of 3D printing may decrease morbidity and mortality of complex, non-routine procedures in cardiovascular medicine.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Cardiovasculares , Impressão Tridimensional , Adolescente , Adulto , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
16.
Ann Thorac Surg ; 97(6): 2160-3, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24882292

RESUMO

PURPOSE: In this study, we show the use of three-dimensional printing models for preoperative planning of surgery for patients with complex aortic arch anomalies. DESCRIPTION: A 70-year-old man with an extensively arteriosclerotic aneurysm reaching from the ascending aorta to the descending aorta was referred to our center for complete aortic arch replacement. We visualized and reconstructed computed tomography data of the patient and fabricated a flexible three-dimensional model of the aortic arch including the aneurysm. EVALUATION: This model was very helpful for the preoperative decision making and planning of the frozen elephant trunk procedure owing to the exact and lifelike illustration of the native aortic arch. CONCLUSIONS: Three-dimensional models are helpful in preoperative planning and postoperative evaluation of frozen elephant trunk procedures in patients with complex aortic anatomy.


Assuntos
Aorta Torácica/cirurgia , Imageamento Tridimensional , Tomografia Computadorizada por Raios X , Idoso , Aorta Torácica/diagnóstico por imagem , Humanos , Masculino , Assistência Perioperatória
18.
Heart Surg Forum ; 16(6): E351-2, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24370806

RESUMO

BACKGROUND: The management of type A intramural hematoma (IMH) is controversial. Although most Western countries still recommend immediate surgical repair, some centers in Asia have shown good results recently with medical treatment alone. Here, we present a case of type A IMH which was discovered during the operation to be a thrombosed type A dissection. CASE REPORT: An 83-year-old female patient presented with acute chest pain. After diagnostic exclusion of myocardial infarction, computed tomography was performed, which showed an IMH from the ascending to the descending aorta. No intimal flap could be detected. The ascending aorta was replaced surgically with a prosthesis. During the operation, we found a ruptured intimal plaque, which had caused dissection of the aorta with thrombosis of the false lumen. The true diagnosis-thrombosed type A dissection and not IMH-was revealed neither by computed tomography nor by transesophageal echocardiography. CONCLUSION: Type A IMH should still be treated with immediate surgical repair because in many cases it turns out to be thrombosed type A dissection.


Assuntos
Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/cirurgia , Idoso de 80 Anos ou mais , Doenças da Aorta/diagnóstico , Diagnóstico Diferencial , Feminino , Hematoma/diagnóstico , Humanos , Resultado do Tratamento
19.
Thorac Cardiovasc Surg ; 61(5): 431-4, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23344755

RESUMO

A 65-year-old male patient was considered inoperable by conventional means for a previous triple coronary artery bypass grafting with a patent in situ right internal mammary artery graft to the left anterior descending artery crossing the thorax at midline directly behind the sternum. Transcatheter aortic valve implantation failed due to loss of the prosthetic device in the left ventricular outflow tract. Mandatory conversion was accomplished by an inferior partial T-shape sternotomy and extracorporeal circulation draining from the right atrium and feeding into the right femoral artery. A conventional 27-mm aortic valve bioprosthesis was successfully implanted during deep hypothermic circulatory arrest. The patient recovered normally exhibiting no neurological or cardiocirculatory complications.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Parada Circulatória Induzida por Hipotermia Profunda , Ponte de Artéria Coronária , Implante de Prótese de Valva Cardíaca/métodos , Esternotomia , Idoso , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Bioprótese , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Ponte de Artéria Coronária/efeitos adversos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Seleção de Pacientes , Desenho de Prótese , Medição de Risco , Fatores de Risco , Tomografia Computadorizada por Raios X , Falha de Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA