Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Cardiovasc Diabetol ; 20(1): 128, 2021 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-34167520

RESUMO

BACKGROUND: The global burden of atrial fibrillation (AF) and diabetes mellitus (DM) is constantly rising, leading to an increasing healthcare burden of stroke. AF often remains undiagnosed due to the occurrence in an asymptomatic, silent form, i.e., silent AF (SAF). The study aims to evaluate the relationships between DM and AF prevalence using a mobile long-term continuous ECG telemonitoring vest in a representative Polish and European population ≥ 65 years for detection of AF, symptomatic or silent. METHODS: A representative sample of 3014 participants from the cross-sectional NOMED-AF study was enrolled in the analyses (mean age 77.5, 49.1% female): 881 (29.2%) were diagnosed with DM. AF was screened using a telemonitoring vest for a mean of 21.9 ± 9.1days. RESULTS: Overall, AF was reported in 680 (22.6%) of the whole study population. AF prevalence was higher among subjects with concomitant DM (DM+) versus those without DM (DM-) [25%, 95% CI 22.5-27.8% vs 17%; 95% CI 15.4-18.5% respectively, p < 0.001]. DM patients were commonly associated with SAF [9%; 95% CI 7.9-11.4 vs 7%; 95% CI 5.6-7.5 respectively, p < 0.001], and persistent/permanent AF [12.2%; 95% CI 10.3-14.3 vs 6.9%; 95% CI 5.9-8.1 respectively, p < 0.001] compared to subjects without DM. The prolonged screening was associated with a higher percentage of newly established AF diagnosis in DM+ vs DM- patients (5% vs 4.5% respectively, p < 0.001). In addition to shared risk factors, DM+ subjects were associated with different AF and SAF independent risk factors compared to DM- individuals, including thyroid disease, peripheral/systemic thromboembolism, hypertension, physical activity and prior percutaneous coronary intervention/coronary artery bypass graft surgery. CONCLUSIONS: AF affects 1 out of 4 subjects with concomitant DM. The higher prevalence of AF and SAF among DM subjects than those without DM highlights the necessity of active AF screening specific AF risk factors assessment amongst the diabetic population. TRIAL REGISTRATION: NCT03243474.


Assuntos
Fibrilação Atrial/epidemiologia , Diabetes Mellitus/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Fibrilação Atrial/diagnóstico , Comorbidade , Estudos Transversais , Diabetes Mellitus/diagnóstico , Diagnóstico Precoce , Eletrocardiografia Ambulatorial/instrumentação , Feminino , Humanos , Masculino , Polônia/epidemiologia , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Tecnologia de Sensoriamento Remoto/instrumentação , Medição de Risco , Fatores de Risco , Dispositivos Eletrônicos Vestíveis
2.
Arch Med Sci ; 16(4): 764-771, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32542076

RESUMO

INTRODUCTION: Implantable cardioverter-defibrillators (ICD) have a strong position in the prevention of sudden death. Nowadays, the most commonly used high-energy cardiac devices are transvenous ICDs. A new technology of totally subcutaneous ICDs (S-ICD) was invented and recently introduced into clinical practice in order to reduce lead-related complications of conventional ICDs. The aim of this paper is to present early experience with this new technology implemented in a few centres in Poland. MATERIAL AND METHODS: Medical records of patients who had S-ICD-related interventions in Poland were retrospectively analysed. RESULTS: During the first year of S-ICD introduction into the Polish health system 18 patients underwent surgery connected with S-ICDs. Majority of them (17 patients) were implanted de novo. In one patient surgical revision of a device implanted abroad was performed. Most of patients (78%) had S-ICDs implanted for secondary prevention. Inability of transvenous system implantation due to venous access obstruction or high risk of infection related with transvenous leads accounted for 83% of indications for S-ICD. Only in three patients were S-ICDs implanted due to young age and active mode of life. The implantations of S-ICDs were performed without important early or late complications. During follow-up one patient had episodes of ventricular arrhythmia successfully terminated with high-energy shocks. One patient died due to progression of heart failure. CONCLUSIONS: S-ICD implantation procedure has been successfully and safely introduced in Polish clinical routine. Nevertheless, despite clear indications in recent ESC guidelines, this therapy is not directly reimbursed in Poland and needs individual application for refund.

3.
Kardiochir Torakochirurgia Pol ; 15(3): 157-161, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30310393

RESUMO

INTRODUCTION: Heart transplant is an accepted treatment modality in end-stage heart failure. The graft coronary artery vasculopathy is a main concern to explain the heterogeneity of the rejection process according to the gender of the donor and recipient. AIM: To assess the severity and type of mechanisms leading to failure of the graft. MATERIAL AND METHODS: Experimental allogenic heart transplantation in the abdomen was performed on Wistar rats depending on the gender of the donor and recipient (F - female; M - male) in four groups (FF, FM, MM MF). The donor heart was implanted in the abdominal cavity of the recipient. Complete time of observation was 10 weeks. Bromodeoxyuridine was administered intraperitoneally to detect proliferating cells. RESULTS: There was 42.5% graft survival in all experiments. The mean time of graft survival was 60 ±18, 54 ±29, 58 ±23 and 64 ±18 days (FF, FM, MM and MF) and no significant difference was found in graft survival time among the four experimental groups (p = 0.73). None of the heart weight changes reached statistical significance. CONCLUSIONS: The use of an animal experimental model helps to understand the mechanisms leading to graft failure and to compare the changes that occur in rats to human hearts. The gender matching affects the survival of the transplanted heart and severity of the graft vasculopathy.

4.
Postepy Hig Med Dosw (Online) ; 71(0): 876-880, 2017 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-29039347

RESUMO

BACKGROUND: Complex mechanisms of responsible for originating and maintaining of atrial fibrillation (AF) are involved in pathophysiology of this arrhythmia. Inflammation substantially contribute to arrhythmic remodelling of atrial tissue.The aim of the present study is to assess an applicability of ferritin and high sensitive C-reactive protein (hs-CRP) as biomarkers of atrial fibrillation and their usefulness in evaluation of efficacy of cryoablation. MATERIALS AND METHODS: The study population consisted of 40 patients who underwent first AF cryoablation procedure. The whole follow-up time was for 6 months. The efficacy of cryoablation was defined as lack of episodes of AF longer than 30 s reported either in patient's medical documentation or present in standard or Holter ECG records. Concentrations of hs-CRP (latex method ) and ferritin (immunochemical method) were determined in standard way in hospital laboratory. RESULTS: The recurrence of atrial fibrillation during follow-up was detected in 7 of 40 patients (efficacy 82.5%). Basal concentrations of hs-CRP and ferritin were significantly higher in patients who underwent ablation during AF. Ablation resulted in an increase of either hs-CRP or ferritin concentrations. After seven days, both hs-CRP and ferritin concentrations returned to basal level. The trend toward the higher concentration of hs-CRP was observed in AF recurrence subgroup in 30th and the 90th day after the procedure. Ferritin concentrations were significantly higher in recurrence subgroup after 30 and 90 days. CONCLUSION: Our results suggest that the evaluation of ferritin serum level can be a potential tool for assessment of AF treatment efficacy.


Assuntos
Fibrilação Atrial/terapia , Ferritinas/análise , Idoso , Fibrilação Atrial/fisiopatologia , Biomarcadores/sangue , Proteína C-Reativa/análise , Criocirurgia , Feminino , Humanos , Inflamação , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
5.
Cardiol J ; 21(4): 405-12, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24671897

RESUMO

BACKGROUND: The aim of this study was to evaluate the value of device-based diagnostic parameters in predicting ventricular arrhythmias in cardiac resynchronization therapy (CRT) recipients. METHODS: Ninety-six CRT-D patients participating in TRUST CRT Trial were analyzed. The inclusion criteria were: heart failure in NYHA ≥ 3 class, QRS ≥ 120 ms, LVEF £ 35% and significant mechanical dyssynchrony. Patients were divided into those with (n = 31, 92 arrhythmias) and without (n = 65) appropriate ICD interventions within follow-up of 12.03 ± 6.7 months. Daily monitored device-based parameters: heart rate (HR), thoracic impedance (TI), HR variability and physical activity were analyzed in 4 time windows: within 10, 7, 3 days and 1 day before appropriate ICD interventions. RESULTS: A consistent pattern of changes in three monitored factors was observed prior to arrhythmia: 1) a gradual increase of day HR (from 103.43% of reference within 10-day window to 105.55% one day before, all p < 0.05 vs. reference); 2) variations in night HR (104.75% in 3 days, 107.65% one day before, all p < 0.05) and 3) TI decrease (from 97.8% in 10 days to 96.81% one day before, all p < 0.05). The combination of three parameters had better predictive value, which improved further after exclusion of patients with atrial fibrillation (AF). The predictive model combining HR and TI together with LVEF and NT-proBNP was more prognostic than the model involving LVEF and NT-proBNP alone (difference in AUC 0.05, 95% CI 0.0005-0.09, p = 0.04). CONCLUSIONS: Daily device-monitored parameters show significant variations prior to ventricular arrhythmia. Combination of multiple parameters improves arrhythmia predictive performance by its additive value to baseline risk factors, while presence of AF diminishes it.


Assuntos
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Telemetria/instrumentação , Actigrafia , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Cardiografia de Impedância , Ritmo Circadiano , Eletrocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Atividade Motora , Polônia , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Processamento de Sinais Assistido por Computador , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
6.
Kardiol Pol ; 70(8): 819-28, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22933215

RESUMO

BACKGROUND: The concept of a hybrid approach, combining the most effective techniques of surgical and endocardial catheter ablation has resulted in the creation of the convergent ablation procedure. This novel, pericardioscopic, hybrid approach can be an effective option for highly symptomatic patients with persistent atrial fibrillation (PSAF) and longstanding persistent atrial fibrillation (LSPAF) for whom standalone surgical or endocardial ablation procedures offer sometimes unsatisfactory outcomes. AIM: To assess the safety, efficacy and effectiveness of a hybrid epicardial and endocardial radiofrequency ablation for the treatment of PSAF and LSPAF. METHODS: Single-centre, prospective, non-randomised clinical study. Between August 2009 and December 2011, 27 patients with PSAF (n = 5) and LSPAF (n = 22) underwent hybrid ablation (HABL). Mean age was 52.52 ± 11.27 years, and the mean EHRA class was 2.5; 14 (51.8%) patients had a history of electrical cardioversion (n = 6) or catheter ablation (n = 8). Five patients had left ventricular ejection fraction (LVEF) of less than 35%. Mean AF duration for all patients was 3.46 ± 2.5 years. All patients were on antiarrhythmic drugs (AAD) and oral anticoagulation. Patients were scheduled for three, six and 12 month follow-up with seven day Holters, REVEAL® XT and ECHO measurements. RESULTS: The HABL procedure was feasible in all patients. At six months post procedure, 72.2% (13/18) of patients were in SR, and 66.5% (12/18) were off class I/III AADs. Four patients were in AF and one patient developed right atrial flutter. At one year post procedure, 80% (8/10) of patients were in SR and off class I/III AADs. At two year post procedure, 100% (6/6) of patients were in SR and off class I/III AADs. Rapid change in left ventricular function was noted in patients with low LVEF (≤ 35%) prior to the procedure. Patients with LVEF +40% had less apparent improvement. CONCLUSIONS: Hybrid, epicardial and endocardial, radiofrequency ablation is feasible and safe, effectively restoring sinus rhythm in the vast majority of patients with PSAF and LSPAF.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/cirurgia , Ablação por Cateter/métodos , Ecocardiografia , Eletrocardiografia Ambulatorial , Perfuração Esofágica/diagnóstico , Perfuração Esofágica/etiologia , Feminino , Seguimentos , Hemorragia/etiologia , Humanos , Lacerações/etiologia , Lacerações/cirurgia , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios , Estudos Prospectivos , Resultado do Tratamento , Veia Cava Inferior/lesões
7.
J Interv Card Electrophysiol ; 28(1): 45-50, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20180007

RESUMO

PURPOSE: Radiofrequency current ablation (RFCA) of ventricular tachycardia (VT) is usually performed using a retrograde transaortic approach. We compared the mapping accuracy, procedural course, safety, and results of VT ablation using transseptal and transaortic route. METHODS: Twenty-one consecutive patients with ischemic cardiomyopathy and history of electrical storm underwent RFCA with electro-anatomic mapping system. In six patients, ablation was performed with transseptal approach (transseptal group); in 15, retrograde approach to the left ventricle was used (retrograde group). RESULTS: The endocardial surface of the left ventricle was similarly accessible in both methods. Less detailed maps of interventricular septum were constructed with the use of transseptal approach. The RFCA success rate was similar in the transseptal and retrograde groups (83 vs. 80%, p = NS). The median procedural time was 112 min in transseptal vs. 145 min in the retrograde group; radiation exposure was 200 vs. 67 mGy, respectively (both p < 0.05), and fluoroscopy time was 22 vs.16 min (p = NS). During the 3-month follow-up, VT recurrence occurred in one patient in the transseptal group and in three patients in the retrograde group (p = NS). CONCLUSIONS: Transseptal approach is an accurate, safe, feasible, and effective method of RF ablation in patients with malignant, recurrent ventricular arrhythmias. However, limited access to the septal regions with the use of this method has to be remembered. Transseptal approach may be considered as an alternative to the transaortic route in patients with contraindication to the latter.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Desfibriladores Implantáveis , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/cirurgia , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/terapia , Estudos de Coortes , Eletrocardiografia , Feminino , Seguimentos , Septos Cardíacos/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Medição de Risco , Índice de Gravidade de Doença , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado do Tratamento
8.
J Thorac Cardiovasc Surg ; 137(5): 1218-24, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19379995

RESUMO

OBJECTIVES: Extracorporeal circulation is associated with the systemic inflammatory response syndrome. The objective of this study was to measure plasma and myocardial matrix metalloproteinase 2 and 9 levels in patients undergoing off-pump coronary artery bypass and coronary artery bypass grafting. METHODS: Twenty patients subjected to coronary artery bypass grafting and 20 subjected to off-pump coronary artery bypass surgery were included in this study. In both procedures blood was collected in 7 equivalent time points up to 12 hours after grafting. The myocardial biopsy specimens were collected before and after extracorporeal circulation in the coronary artery bypass grafting group and after harvesting and completion of proximal anastomoses in the off-pump coronary artery bypass group. Matrix metalloproteinase levels were measured by means of zymography. Myeloperoxidase and tissue inhibitor of metalloproteinase 1 and 2 levels were measured with an enzyme-linked immunosorbent assay. RESULTS: Coronary artery bypass grafting but not off-pump coronary artery bypass led to a 700- to 900-fold increase of plasma matrix metalloproteinase 9 levels. A small but significant increase in matrix metalloproteinase 2 levels was detected in both procedures. Myocardial matrix metalloproteinase 9 levels significantly increased at the end of coronary artery bypass grafting and off-pump coronary artery bypass. Increased matrix metalloproteinase 9 activity at the end of extracorporeal circulation was accompanied by augmentation of the endogenous matrix metalloproteinase inhibitors tissue inhibitor of metalloproteinase 1 and 2 in plasma, but its magnitude was unable to balance the plasma matrix metalloproteinase 9 increase. The matrix metalloproteinase 9 content in plasma at the end of extracorporeal circulation correlated with the myeloperoxidase plasma concentration (r(2) = 0.8212, P < 0.05). CONCLUSION: We propose that release of matrix metalloproteinase 9 might contribute to the extracorporeal circulation-induced inflammatory reactions.


Assuntos
Ponte de Artéria Coronária/métodos , Doença das Coronárias/cirurgia , Metaloproteinase 2 da Matriz/metabolismo , Metaloproteinase 9 da Matriz/metabolismo , Idoso , Biomarcadores/análise , Estudos de Coortes , Ponte de Artéria Coronária/mortalidade , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Ponte de Artéria Coronária sem Circulação Extracorpórea/mortalidade , Doença das Coronárias/enzimologia , Doença das Coronárias/mortalidade , Ensaio de Imunoadsorção Enzimática , Feminino , Seguimentos , Humanos , Masculino , Metaloproteinase 2 da Matriz/análise , Metaloproteinase 9 da Matriz/análise , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/fisiopatologia , Probabilidade , Medição de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Análise de Sobrevida , Resultado do Tratamento
10.
Cell Mol Biol Lett ; 8(1): 171-7, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12655371

RESUMO

This study was performed to evaluate the protective effects of pyrroline and pyrrolidine nitroxides Pirolin, PL, and Pirolid, PD, on the plasma membranes of rat cardiomyocytes treated in vitro with anthracycline drugs aclarubicin (ACL) and doxorubicin (DOX). The influence of two concentrations of drugs (10 and 20 microM) and nitroxides (0.1 and 1 mM) as well as their combinations (a drug and a nitroxide) on membrane fluidity was investigated. The plasma membranes of cardiomyocytes were labelled with a hydrophobic fluorescence probe 12-AS and membrane fluidity was estimated on the basis of the fluorescence anisotropy of the probe. We found that aclarubicin and doxorubicin induced a significant dose-dependent decrease in membrane fluidity, whereas the nitroxides (PL and PD) caused its increase. Preincubation of cardiomyocytes with Pirolin entirely protected plasma membranes of these cells against damage caused by DOX. In the same conditions no protective effect of Pirolid was observed. What is more, Pirolid in combination with DOX caused fluidisation of the plasma membranes of cardiomyocytes. Both nitroxides at low concentration (0.1 mM) protected plasma membranes against rigidification induced by aclarubicin, while high concentration (1 mM) was ineffective and caused fluidisation of the plasma membranes of cardiomyocytes.


Assuntos
Antraciclinas/toxicidade , Óxidos N-Cíclicos/farmacologia , Miócitos Cardíacos/efeitos dos fármacos , Pirróis/farmacologia , Pirrolidinas/farmacologia , Aclarubicina/antagonistas & inibidores , Aclarubicina/toxicidade , Animais , Antraciclinas/antagonistas & inibidores , Antibióticos Antineoplásicos/antagonistas & inibidores , Antibióticos Antineoplásicos/toxicidade , Membrana Celular/efeitos dos fármacos , Membrana Celular/metabolismo , Doxorrubicina/antagonistas & inibidores , Doxorrubicina/toxicidade , Polarização de Fluorescência , Corantes Fluorescentes , Técnicas In Vitro , Masculino , Fluidez de Membrana/efeitos dos fármacos , Miócitos Cardíacos/metabolismo , Óxidos de Nitrogênio/farmacologia , Ratos , Ratos Wistar , Ácidos Esteáricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA