Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Quant Imaging Med Surg ; 14(6): 4141-4154, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38846278

RESUMO

Background: Bone erosion in the sacroiliac joint (SIJ) is highly specific for the diagnosis of axial spondyloarthritis (axSpA) and may indicate early disease progression. The 3D ultrashort echo time (3D-UTE) technique excels in providing clear contrast between the articular cartilage and the bone cortex interface. Additionally, it is emerging as a promising quantitative tool for detecting early cartilage changes. Therefore, this study aimed to evaluate the diagnostic performance of 3D-UTE sequences in identifying bone erosion in the SIJ of patients with axSpA and to clarify the potential of cartilage T2* values as a quantitative biomarker for axSpA. Methods: This prospective study employed convenience and consecutive sampling methods to recruit patients diagnosed with axSpA in Peking University Third Hospital who met the Assessment of Spondyloarthritis International Society (ASAS) criteria and also an equal number of healthy volunteers. After providing informed consent, all participants underwent 3D-UTE sequences and conventional T2* mapping of the SIJs. Two radiologists separately interpreted the bone erosion of each SIJ on 3D-UTE sequences. Erosion detection of SIJs via computed tomography (CT) served as the standard of reference. The T2* values of the cartilage were measured and compared, and the diagnostic efficacy of the T2* value for axSpA diagnosis was evaluated. Results: A total of 32 patients and 32 healthy volunteers were included. The 3D-UTE sequence, as separately assessed by two reviewers in terms of its ability to detect erosions, exhibited a notable level of accuracy. For the two reviewers, the respective diagnostic sensitivities were 94.7% and 92.9%, the specificities were 97.4% and 96.5%, positive predictive values were 96.7% and 95.4%, the negative predictive values were 95.9% and 94.5%, the accuracies were 96.2% and 94.9%, and the areas under the curve (AUCs) were 96.1% and 94.7%. For the detection of erosions, the interreader κ value was 0.949. The T2* values of the SIJ cartilage were significantly higher in patients with axSpA than in healthy volunteers. The intraobserver intraclass correlation coefficients (ICCs) for T2* measurements ranged between 80.5% and 82.2%. Meanwhile, the interobserver ICCs for UTE-T2* and gradient echo T2* measurements were 81.5% and 80.8%, respectively. The AUCs of the UTE-T2* values for discriminating patients with axSpA from the healthy volunteers of the two readers were 73.3% and 71.6%, respectively. Conclusions: 3D-UTE sequences can be used as a reliable morphological imaging technique for detecting bone erosion in the SIJ. Additionally, UTE-T2* values of the cartilage may offer a quantitative method for identifying patients with axSpA.

2.
J Craniomaxillofac Surg ; 52(1): 117-126, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37891089

RESUMO

This study aimed to compare preoperative data relevant to third molar surgery based on radiographic orthopantomography (OPG) and orthopantomogram-like MR images (MR-OPG), using five different MR protocols. X-ray-based OPG and OPG-like MRI reconstructions from DESS, SPACE-STIR, SPACE-SPAIR, T1-VIBE-Dixon, and UTE sequences were acquired in 11 patients undergoing third molar surgery, using a 15-channel mandibular coil. Qualitative (image quality, susceptibility to artifacts, positional relationship, contact/non-contact of the inferior alveolar nerve (IAN), relationship to maxillary sinus, IAN continuity, root morphology) and quantitative (tooth length, retromolar distance, distance to the IAN, and distance to the mandible margin) parameters of the maxillary and mandibular third molars were assessed regarding inter-reader agreement and quantitative discrepancies by three calibrated readers. Radiation-free MR-OPGs generated within clinically tolerable acquisition times, which exhibited high image quality and low susceptibility to artifacts, showed no significant differences compared with X-ray-based OPGs regarding the assessment of quantitative parameters. UTE MR-OPGs provided radiographic-like images and were best suited for assessing qualitative preoperative data (positional relationship, nerve contact/non-contact, and dental root morphology) relevant to third molar surgery. For continuous and focal nerve imaging, DESS MR-OPG was superior. MR-OPGs could represent a shift towards indication-specific and modality-oriented perioperative imaging in high-risk oral and maxillofacial surgery.


Assuntos
Dente Impactado , Traumatismos do Nervo Trigêmeo , Humanos , Dente Serotino/diagnóstico por imagem , Dente Serotino/cirurgia , Raios X , Radiografia Panorâmica/métodos , Imageamento por Ressonância Magnética/métodos , Dente Impactado/cirurgia , Extração Dentária , Espectroscopia de Ressonância Magnética , Nervo Mandibular , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Mandíbula/inervação , Traumatismos do Nervo Trigêmeo/diagnóstico por imagem
3.
Quant Imaging Med Surg ; 13(12): 7893-7909, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38106304

RESUMO

Background: Knee tissues such as tendon, ligament and meniscus have short T2* relaxation times and tend to show little to no signal in conventional magnetic resonance acquisitions. An ultrashort echo time (UTE) technique offers a unique tool to probe fast-decaying signals in these tissues. Clinically relevant factors should be evaluated to quantify the sensitivity needed to distinguish diseased from control tissues. Therefore, the objectives of this study were to (I) quantify the repeatability of UTE-T2* relaxation time values, and (II) evaluate the effects of fat suppression and (III) knee positioning on UTE-T2* relaxation time quantification. Methods: A dual-echo, three-dimensional center-out radially sampling UTE and conventional gradient echo sequences were utilized to image gadolinium phantoms, one ex-vivo specimen, and five in-vivo subjects on a clinical 3T scanner. Scan-rescan images from the phantom and in-vivo experiments were used to evaluate the repeatability of T2* relaxation time values. Fat suppressed and non-suppressed images were acquired for phantoms and the ex-vivo specimen to evaluate the effect of fat suppression on T2* relaxation time quantifications. The effect of knee positioning was evaluated by imaging in-vivo subjects in extended and flexed positions within the knee coil and comparing T2* relaxation times quantified from tissues in each position. Results: Phantom and in-vivo measurements demonstrated repeatable T2* mapping, where the percent difference between T2* relaxation time quantified from scan-rescan images was less than 8% for the phantom and knee tissues. The coefficient of variation across fat suppressed and non-suppressed images was less than 5% for the phantoms and ex-vivo knee tissues, showing that fat suppression had a minimal effect on T2* relaxation time quantification. Knee position introduced variability to T2* quantification of the anterior cruciate ligament, posterior cruciate ligament, and patellar tendon, with percent differences exceeding 20%, but the meniscus showed a percent difference less than 10%. Conclusions: The 3D radial UTE sequence presented in this study could potentially be used to detect clinically relevant changes in mean T2* relaxation time, however, reproducibility of these values is impacted by knee position consistency between scans.

5.
Polymers (Basel) ; 15(8)2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37112071

RESUMO

The increasing demand for renewable raw materials and lightweight composites leads to an increasing request for natural fiber composites (NFC) in series production. In order to be able to use NFC competitively, they must also be processable with hot runner systems in injection molding series production. For this reason, the influences of two hot runner systems on the structural and mechanical properties of Polypropylene with 20 wt.% regenerated cellulose fibers (RCF) were investigated. Therefore, the material was processed into test specimens using two different hot runner systems (open and valve gate) and six different process settings. The tensile tests carried out showed very good strength for both hot runner systems, which were max. 20% below the reference specimen processed with a cold runner and, however, significantly influenced by the different parameter settings. Fiber length measurements with the dynamic image analysis showed approx. 20% lower median values of GF and 5% lower of RCF through the processing with both hot runner systems compared to the reference, although the influence of the parameter settings was small. The X-ray microtomography performed on the open hot runner samples showed the influences of the parameter settings on the fiber orientation. In summary, it was shown that RCF composites can be processed with different hot runner systems in a wide process window. Nevertheless, the specimens of the setting with the lowest applied thermal load showed the best mechanical properties for both hot runner systems. It was furthermore shown that the resulting mechanical properties of the composites are not only due to one structural property (fiber length, orientation, or thermally induced changes in fiber properties) but are based on a combination of several material- and process-related properties.

6.
Sci Rep ; 13(1): 6228, 2023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-37069287

RESUMO

This prospective study aimed to present, compare, and evaluate the suitability of five different magnetic resonance imaging (MRI) protocols (3D double-echo steady-state (DESS), 3D fast spin echo short-tau inversion recovery (SPACE-STIR), 3D fast spin echo spectral attenuated inversion recovery (SPACE-SPAIR), volumetric interpolated breath-hold examination (T1-VIBE-Dixon), and ultrashort echo time (UTE)) and for orthopantomogram (OPG)-like MRI reconstructions using a novel mandibular coil. Three readers assessed MR-OPGs of 21 volunteers regarding technical image quality (4, excellent; 0, severely reduced), susceptibility to artifacts (3, absence; 0, massive), and visualization of anatomical structures in the oral cavity and surrounding skeletal structures (4, fine details visible; 0, no structures visible). Average image quality was good (3.29 ± 0.83) for all MRI protocols, with UTE providing the best image quality (3.52 ± 0.62) and no to minor artifacts (2.56 ± 0.6). Full diagnostic interpretability of the osseous structures is best in VIBE-Dixon and UTE MR-OPGs. DESS provided excellent visualization of the finest details of the nervous tissue (3.95 ± 0.22). Intra-reader and inter-reader agreement between the readers was good to excellent for all protocols (ICCs 0.812-0.957). MR-OPGs provide indication-specific accurate imaging of the oral cavity and could contribute to the early detection of pathologies, staging, and radiological follow-up of oral and maxillofacial diseases.


Assuntos
Dentística Operatória , Cirurgia Bucal , Humanos , Radiografia Panorâmica , Estudo de Prova de Conceito , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos
7.
Dtsch Med Wochenschr ; 148(1-02): e1-e7, 2023 01.
Artigo em Alemão | MEDLINE | ID: mdl-36423615

RESUMO

BACKGROUND: The incidence of diabetes mellitus and cardiovascular diseases is increasing worldwide and also in Germany. The aim of the study was to assess the health literacy regarding these diseases in childhood and adolescence. METHODS: Students of the 5th-12th grade (grammar school ("Gymnasium"), secondary school forms ("Realschule" and "Hauptschule")) were interviewed in 2007 (n = 4383) and 2019 (n = 572) about diabetes and secondary complications. In addition, questions about other cardiovascular risk factors were asked in 2019. RESULTS: Diabetes-related questions were answered correctly by 56 % in 2007 as well as 53 % in 2019. Among others, 70 % (2007) as well as 75 % (2019) of the students stated "ate too much sugar" as a cause for type 1 diabetes. Further, questions about major risk factors for heart attack and stroke were answered correctly by only 33 % (for diabetes) and 43 %-53 % (for smoking) of students.Across all questions, a positive association indicated between the rate of correct answers and the educational level of the school institution; however, the differences remained marginal at 5-19 % between Gymnasium and Hauptschule or Realschule at both survey time points. A difference between genders was indicated in 2007 (girls: 59 % vs. boys: 52 %) and 2019 (girls: 56 % vs. boys: 51 %). CONCLUSION: Changes in health literacy regarding diabetes and other cardiovascular risk factors among 5th-12th grade students over the past 12 years could not be observed. The assumed self-infliction of type 1 diabetes may be perceived as discrimination by those affected.


Assuntos
Diabetes Mellitus Tipo 1 , Letramento em Saúde , Humanos , Masculino , Feminino , Adolescente , Diabetes Mellitus Tipo 1/epidemiologia , Seguimentos , Escolaridade , Estudantes , Inquéritos e Questionários
8.
Arch Orthop Trauma Surg ; 143(6): 2965-2971, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35767038

RESUMO

BACKGROUND: The anteroposterior (ap) radiograph of the pelvis is decisive in the diagnosis of different pathologies of the hip joint. Technical advantages have reduced the radiation dose of pelvic CT to levels comparable to radiographs. The purpose of this study was to validate if standard radiographic parameters (lateral center edge angle, medial center edge angle, acetabular index, acetabular arc, extrusion index, crossover sign and posterior wall sign) can accurately be determined on radiograph-like projections reconstructed from the CT dataset pre- and postoperatively. METHODS: A consecutive series of patient with symptomatic dysplasia of the hip and a full radiologic workup (radiographs and CT scan pre- and postoperatively) who underwent periacetabular osteotomy were included. Standard radiographic parameters were compared between radiographs and radiograph-like projections by two authors pre- and postoperatively. RESULTS: A total of 16 hips (32 radiographs/32 radiograph-like projections) were included in the study. No significant difference was found between the radiographs and radiograph-like images for all parameter for both examiners. ICC between radiograph and radiograph-like projections for all investigated parameters showed good to excellent reliability (0.78-0.99) pre- and postoperatively. CONCLUSION: Radiograph-like projections show comparable results to radiographs with regard to the important investigated parameters (lateral center edge angle, medial center edge angle, acetabular index, acetabular arc, extrusion index, crossover sign and posterior wall sign). Thus, ultra-low-dose CT scans may reduce the need for conventional radiographs in pre- and postoperative analyses of 3-dimensional hip pathologies in the future, as the advantages increasingly outweigh the disadvantages.


Assuntos
Acetábulo , Articulação do Quadril , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acetábulo/patologia , Pelve , Tomografia Computadorizada por Raios X
9.
Invest Radiol ; 56(9): 545-552, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33813573

RESUMO

OBJECTIVES: Through-slice chemical shift artifacts in state-of-the-art turbo-spin-echo (TSE) images can be significantly more severe at 7 T than at lower field strengths. In musculoskeletal applications, these artifacts appear similar to bone fractures or neoplastic bone marrow disease. The objective of this work was to explore and reduce through-slice chemical shift artifacts in 2-dimensional (2D) TSE imaging at 7 T. MATERIALS AND METHODS: This prospective study was approved by the local ethics board. The bandwidths of the excitation and refocusing radiofrequency (RF) pulses of a prototype 2D TSE sequence were individually modified and their effect on the slice profiles and relative slice locations of water and fat spins was assessed in an oil-water phantom. Based on these results, it was hypothesized that the combination of matched and increased excitation and refocusing RF pulse bandwidths ("MIB") of 1500 Hz would enable 2D TSE imaging with significantly reduced chemical shift artifacts compared with a state-of-the-art sequence with unmatched and moderate RF pulse bandwidths ("UMB") of 1095 and 682 Hz.A series of T1-weighted sagittal knee examinations in 10 healthy human subjects were acquired using the MIB and UMB sequences and independently evaluated by 2 radiologists. They measured the width of chemical shift artifacts at 2 standardized locations and graded the perceived negative effect of chemical shift artifacts on image quality in the bones and in the whole gastrocnemius muscle on a 5-point scale. Similar knee, wrist, and foot images were acquired in a single subject. Signal-to-noise ratios in the femoral bone marrow were computed between the UMB and MIB sequences. RESULTS: Phantom measurements confirmed the expected spatial separation of simultaneously affected water and fat slices between 40% and 200% of the prescribed slice thickness for RF pulse bandwidths between 2500 and 500 Hz. Through-slice chemical shift artifacts at the bone-cartilage interface were significantly smaller with MIB than with UMB (location 1: 0.35 ± 0.20 mm vs 1.27 ± 0.27 mm, P < 0.001; location 2: 0.25 ± 0.13 mm vs 1.48 ± 0.46 mm, P < 0.001; intraclass correlation coefficient = 0.98). The negative effect of chemical shift artifacts on image quality was significantly smaller with MIB than with UMB (bone: 2 ± 0 vs 4 ± 1, P < 0.004 [both readers]; muscle: 3 ± 0 vs 2 ± 0, P < 0.004 [both readers]; κ = 0.69). The signal-to-noise ratio of the UMB and MIB sequences was comparable, with a ratio of 99 ± 7%. Images acquired using the UMB sequence displayed numerous artifactual hyperintensities and diffuse, as well as locally severe, fat signal loss in all examined regions, whereas the MIB sequence consistently yielded high image quality with bright T1-weighted fat signal and excellent depiction of fine tissue structures. CONCLUSIONS: On 7 T systems, the selection of high and matched RF bandwidths for excitation and refocusing pulses for 2D TSE imaging without fat suppression showed consistently better image quality than state-of-the-art sequences with unmatched lower RF pulse bandwidths.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Humanos , Imagens de Fantasmas , Estudos Prospectivos , Razão Sinal-Ruído
10.
J Clin Endocrinol Metab ; 100(10): 3752-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26287961

RESUMO

CONTEXT: Physiological gynecomastia is common and affects a large proportion of otherwise healthy adolescent boys. It is thought to be caused by an imbalance between estrogen and testosterone, although this is rarely evident in analyses of serum. OBJECTIVE: This study aimed to describe the frequency of physiological gynecomastia and to determine possible etiological factors (eg, auxology and serum hormone levels) in a longitudinal setup. DESIGN, SETTINGS, AND PARTICIPANTS: A prospective cohort study of 106 healthy Danish boys (5.8-16.4 years) participated in the longitudinal part of the COPENHAGEN Puberty Study. The boys were examined every 6 months during an 8-year follow-up. Median number of examinations was 10 (2-15). MAIN OUTCOME MEASUREMENTS: Blood samples were analyzed for FSH, LH, testosterone, estradiol, SHBG, inhibin B, anti-Müllerian hormone, IGF-1, and IGF binding protein-3 by immunoassays. Auxological parameters, pubertal development, and the presence of gynecomastia were evaluated at each visit. RESULTS: Fifty-two of 106 boys (49%) developed gynecomastia, of which 10 (19%) presented with intermittent gynecomastia. Boys with physiological gynecomastia reached peak height velocity at a significantly younger age than boys who did not develop gynecomastia (13.5 versus 13.9 years, P = .027), and they had significantly higher serum levels of IGF-1 (P = .000), estradiol (P = .013), free testosterone (P < .001), and FSH (P = .030) during pubertal transition. However, no differences in serum LH or in the estradiol to testosterone ratio were found. CONCLUSIONS: Gynecomastia is frequent in pubertal boys. Increased IGF-1 levels and pubertal growth appear to be associated, whereas changes in estrogen to testosterone ratio seem negligible.


Assuntos
Estatura/fisiologia , Estradiol/sangue , Ginecomastia/fisiopatologia , Fator de Crescimento Insulin-Like I/metabolismo , Testosterona/sangue , Adolescente , Hormônio Antimülleriano/sangue , Criança , Pré-Escolar , Hormônio Foliculoestimulante/sangue , Ginecomastia/sangue , Humanos , Inibinas/sangue , Proteína 3 de Ligação a Fator de Crescimento Semelhante à Insulina/sangue , Estudos Longitudinais , Hormônio Luteinizante/sangue , Masculino , Estudos Prospectivos , Puberdade/sangue , Puberdade/fisiologia , Globulina de Ligação a Hormônio Sexual/metabolismo
12.
Naturwissenschaften ; 90(6): 273-6, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12835839

RESUMO

Rotifers, one of the smallest metazoans, are only seldom found in marine environments. Surprisingly, we discovered high abundances of at least two new species of rotifers settling in anoxic and highly sulphidic sediments associated with shallow gas hydrates (GH) at the southern crest of Hydrate Ridge off Oregon, NE Pacific, in a water depth of about 780 m. At basins adjacent to Hydrate Ridge, 1,285-2,304 m deep, we found rotifers co-occurring with the sulphide-oxidising bacteria Thioploca sp.


Assuntos
Meio Ambiente , Sedimentos Geológicos/análise , Animais , Densidade Demográfica , Rotíferos/crescimento & desenvolvimento , Água do Mar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA