Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
Gland Surg ; 13(6): 1144-1145, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-39015711
2.
Plast Reconstr Surg ; 153(1): 10e-24e, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37010460

RESUMO

BACKGROUND: Implant-based breast reconstruction has evolved over time. However, the effects of prepectoral breast reconstruction (PBR) compared with those of subpectoral breast reconstruction (SBR) have not been clearly defined. Therefore, this study aimed to compare the occurrence of surgical complications between PBR and SBR to determine the procedure that is effective and relatively safe. METHODS: The PubMed, Cochrane Library, and EMBASE databases were searched for studies published until April of 2021 comparing PBR and SBR following mastectomy. Two authors independently assessed the risk of bias. General information on the studies and surgical outcomes were extracted. Among 857 studies, 34 and 29 were included in the systematic review and meta-analysis, respectively. Subgroup analysis was performed to clearly compare the results of patients who underwent postmastectomy radiation therapy. RESULTS: Pooled results showed that prevention of capsular contracture (OR, 0.57; 95% CI, 0.41 to 0.79) and infection control (OR, 0.73; 95% CI, 0.58 to 0.92) were better with PBR than with SBR. Rates of hematoma, implant loss, seroma, skin-flap necrosis, and wound dehiscence were not significantly different between PBR and SBR. PBR considerably improved postoperative pain, BREAST-Q score, and upper arm function compared with SBR. Among postmastectomy radiation therapy patients, the incidence rates of capsular contracture were significantly lower in the PBR group than in the SBR group (OR, 0.14; 95% CI, 0.05 to 0.35). CONCLUSIONS: The results showed that PBR had fewer postoperative complications than SBR. The authors' meta-analysis suggests that PBR could be used as an alternative technique for breast reconstruction in appropriate patients.


Assuntos
Implante Mamário , Implantes de Mama , Neoplasias da Mama , Contratura , Mamoplastia , Humanos , Feminino , Neoplasias da Mama/etiologia , Mastectomia/efeitos adversos , Mastectomia/métodos , Implante Mamário/efeitos adversos , Implante Mamário/métodos , Mamoplastia/efeitos adversos , Mamoplastia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Contratura/etiologia , Implantes de Mama/efeitos adversos
3.
Arch Plast Surg ; 50(6): 541-549, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38143837

RESUMO

Background Despite its many advantages, prepectoral breast reconstruction also carries the risk of implant rippling. The recent introduction of partial superior implant coverage using a pectoralis muscle slip in prepectoral direct-to-implant (DTI) breast reconstruction has shown the potential to minimize upper pole rippling. The purpose of this study was to identify factors associated with rippling and the effectiveness of our surgical technique. Methods In total, 156 patients (186 breasts) who underwent prepectoral DTI breast reconstruction between August 2019 and March 2021 were identified retrospectively. Patient data were analyzed from medical records. Univariable and multivariable logistic analyses were performed to contextualize the risks associated with rippling deformity relative to demographic characteristics and other clinical factors. Retrospective propensity-matched analysis was performed to identify the relationship between rippling deformity and the reconstruction method. Results Patients with body mass index (BMI; odds ratio [OR], 0.736; p < 0.001), those with a postoperative chemotherapy history (OR, 0.324; p = 0.027) and those who received breast reconstruction via the superior coverage technique (OR, 0.2; p = 0.004), were less likely to develop rippling deformity. The median follow-up period was 64.9 weeks, and there were no significant differences between patients in types of mastectomy, implant, or acellular dermal matrix. Patients who underwent superior coverage technique-based reconstruction showed significantly reduced rippling (OR, 0.083; p = 0.017) Conclusion Patients with higher BMI and prior postoperative chemotherapy were less likely to develop rippling deformity. The superior coverage technique can be effective in minimizing upper pole rippling.

4.
Front Oncol ; 13: 1211593, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38023138

RESUMO

Background: Sarcopenia is characterized by the loss of skeletal muscle mass and power. Preoperative sarcopenia may be associated with an increased risk of postoperative complications after autologous free-flap breast reconstruction surgery; however, this relationship is controversial. Objectives: This study aimed to determine whether preoperative sarcopenia is associated with a high complication rate in patients undergoing autologous free-flap breast reconstruction. Methods: Patients who underwent autologous free-flap breast reconstruction at our hospital between 2019 and 2021 were included in the study. Data on significant complications requiring surgical intervention were retrospectively collected from the medical records. Sarcopenia was defined as having a skeletal muscle index value <41 cm2/m2. The skeletal muscle index was calculated by dividing the sum of the psoas and iliopsoas muscle areas at the level of the third lumbar vertebra by the patient's height in meters squared. The relationship between preoperative sarcopenia and postoperative complications was investigated using an inverse probability of treatment weighting (IPTW) analysis. Results: Among the 203 participants, 90 (44.33%) had preoperative sarcopenia. The general patient characteristics were similar between the sarcopenia and non-sarcopenia groups after IPTW adjustment. Sarcopenia did not significantly increase the risk of flap failure or emergency surgery related to breast reconstruction before IPTW adjustment. However, after IPTW adjustment, the rates of recipient site infection and hematoma were significantly higher in participants with sarcopenia than in those without sarcopenia (p < 0.001 and p = 0.014, respectively). Conclusion: Preoperative sarcopenia may influence certain complications of autologous free-flap breast reconstruction surgery.

5.
Plast Reconstr Surg ; 2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37904276

RESUMO

Deep inferior epigastric perforator (DIEP) flap surgery is a common technique for breast reconstruction. However, the long and noticeable abdominal scarring is one of its greatest disadvantages. Here, we suggest a minimal scarring DIEP flap harvest with a novel abdominal design. The key to this method is to preserve more skin tissue with a circular design centered around the navel. Three circular incisions are made: (1) the smallest circle represents an incision around the umbilicus; (2) the middle circle with a radius of <3.5 cm indicates skin incision because the donut-like skin paddle between the small and middle circles is included in the flap; (3) the largest circle with a radius of >10 cm represents the extent of flap dissection that was done diagonally from the skin toward the Scarpa's fascia. Pedicle dissection is proceeded with the conventional method. For closure, a purse-string suture is performed with the umbilicus at its center leaving only a single small circular scar around the umbilicus as the final scar. Closure of the donor-site is possible with the patient in a supine or slightly flexed position due to less skin excision. LEVEL OF EVIDENCE: Therapeutic, V.

6.
Plast Reconstr Surg ; 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37797243

RESUMO

BACKGROUND: This study aimed to analyze the novel operative outcomes of breast mound reconstruction followed by robot-assisted mastectomy in retrospective review. METHOD: Patients who underwent nipple-sparing mastectomy with a robotic device (Da Vinci Xi) and immediate prosthetic reconstruction prepectorally via lateral incision from June 2018 to July 2019 were enrolled. Patient characteristics, complications, and satisfaction via BREAST-Q were analyzed. The surgical technique was described in detail. RESULTS: Thirty-nine cases, including 7 bilateral cases (total 46 breasts), underwent robot-assisted nipple-sparing mastectomy followed by immediate prosthetic implant reconstruction prepectorally. The median patient age was 46.63 years (range: 21-63 years). The mean operation time for each prepectoral breast mound reconstruction using the direct-to-implant technique was 126.55 min. Overall satisfaction of robotic use was evaluated as superior to the conventional reconstruction method using BREAST-Q. Major infection was found in seven cases (15.2%), and complete nipple loss was found in three cases (6.6%). Severe complications requiring breast implant removal in the surgical technique occurred in four breasts (8.7%). Two cases were due to the coexistence of infection and skin necrosis; in one case, the skin flap had undergone the congestive phase on postoperative day (POD) 3 and required additional surgery to change the expander. Other complications were resolved by conservative care or minor revision. CONCLUSION: This report is the first concerning robot-assisted NSM followed by prepectoral ADM-wrapped prosthetic reconstruction. In our experience, this procedure seems to be not inferior to other methods. Further prospective research to evaluate oncologic outcomes is warranted.

7.
Tissue Eng Regen Med ; 20(4): 607-619, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37017922

RESUMO

BACKGROUND: Breast cancer patients suffer from lowered quality of life (QoL) after surgery. Breast conservancy surgery (BCS) such as partial mastectomy is being practiced and studied as an alternative to solve this problem. This study confirmed breast tissue reconstruction in a pig model by fabricating a 3-dimensional (3D) printed Polycaprolactone spherical scaffold (PCL ball) to fit the tissue resected after partial mastectomy. METHODS: A 3D printed Polycaprolactone spherical scaffold with a structure that can help adipose tissue regeneration was produced using computer-aided design (CAD). A physical property test was conducted for optimization. In order to enhance biocompatibility, collagen coating was applied and a comparative study was conducted for 3 months in a partial mastectomy pig model. RESULTS: In order to identify adipose tissue and fibroglandular tissue, which mainly constitute breast tissue, the degree of adipose tissue and collagen regeneration was confirmed in a pig model after 3 months. As a result, it was confirmed that a lot of adipose tissue was regenerated in the PCL ball, whereas more collagen was regenerated in the collagen-coated Polycaprolactone spherical scaffold (PCL-COL ball). In addition, as a result of confirming the expression levels of TNF-a and IL-6, it was confirmed that PCL ball showed higher levels than PCL-COL ball. CONCLUSION: Through this study, we were able to confirm the regeneration of adipose tissue through a 3-dimensional structure in a pig model. Studies were conducted on medium and large-sized animal models for the final purpose of clinical use and reconstruction of human breast tissue, and the possibility was confirmed.


Assuntos
Neoplasias da Mama , Alicerces Teciduais , Humanos , Animais , Suínos , Feminino , Alicerces Teciduais/química , Qualidade de Vida , Mastectomia Segmentar , Mastectomia , Colágeno/química
8.
Plast Reconstr Surg ; 151(2): 214e-222e, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36696309

RESUMO

BACKGROUND: With the increasing number of patients undergoing immediate breast reconstruction after mastectomy, the impact of immediate breast reconstruction on the risk of breast cancer-related lymphedema has become an emerging area of interest. This study aimed to identify the association between immediate breast reconstruction and postoperative lymphedema. METHODS: A retrospective cohort study was conducted from 2006 to 2016 with 5900 consecutive patients who underwent mastectomy for primary breast cancer with or without immediate breast reconstruction. After excluding patients with synchronous contralateral breast cancer, lymphedema before mastectomy, history of procedures performed in the axillary region, and follow-up data of less than 1 year, the cumulative incidence of lymphedema after immediate breast reconstruction and after no reconstruction was calculated and compared using multivariate Cox regression analysis. RESULTS: Overall, 5497 patients (mean age, 51.7 years) were included, and 630 developed lymphedema. The 5-year cumulative incidence rate of lymphedema was significantly reduced in patients who underwent immediate breast reconstruction versus control patients (9.6% versus 12.2%; P = 0.02). In the multivariate analysis, immediate breast reconstruction status (hazard ratio, 0.75; 95% confidence interval, 0.56 to 0.99; P = 0.042) was an independent predictor for lymphedema. Similar significant associations were observed in the subgroup analyses of patients with a body mass index less than 30 kg/m2 (P = 0.024), in those with fewer than 10 dissected lymph nodes (P = 0.042), or in those with adjuvant radiotherapy (P = 0.048). CONCLUSIONS: Immediate breast reconstruction was associated with a reduced risk of lymphedema. These results may be used for predicting the development of lymphedema following breast reconstruction. CLINICAL QUESTION/LEVEL OF EVIDENCE: Risk, II.


Assuntos
Linfedema Relacionado a Câncer de Mama , Neoplasias da Mama , Linfedema , Mamoplastia , Humanos , Pessoa de Meia-Idade , Feminino , Mastectomia/efeitos adversos , Mastectomia/métodos , Neoplasias da Mama/patologia , Estudos Retrospectivos , Seguimentos , Fatores de Risco , Mamoplastia/efeitos adversos , Mamoplastia/métodos , Linfedema Relacionado a Câncer de Mama/epidemiologia , Linfedema Relacionado a Câncer de Mama/etiologia , Linfedema/epidemiologia , Linfedema/etiologia , Linfedema/cirurgia , Excisão de Linfonodo/efeitos adversos
9.
Surgery ; 172(6S): S46-S53, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36427930

RESUMO

BACKGROUND: In recent years, indocyanine green angiography (ICG-A) has been used increasingly to assist tissue perfusion assessments during plastic and reconstructive surgery procedures, but no guidelines exist regarding its use. We sought to identify areas of consensus and non-consensus among international experts on the use of ICG-A for tissue-perfusion assessments during plastic and reconstructive surgery. METHODS: A two-round, online Delphi survey was conducted of 22 international experts from four continents asking them to vote on 79 statements divided into five modules: module 1 = patient preparation and contraindications (n = 11 statements); module 2 = ICG administration and camera settings (n = 17); module 3 = other factors impacting perfusion assessments (n = 10); module 4 = specific indications, including trauma debridement (n = 9), mastectomy skin flaps (n = 6), and free flap reconstruction (n = 8); and module 5 = general advantages and disadvantages, training, insurance coverage issues, and future directions (n = 18). Consensus was defined as ≥70% inter-voter agreement. RESULTS: Consensus was reached on 73/79 statements, including the overall value, advantages, and limitations of ICG-A in numerous surgical settings; also, on the dose (0.05 mg/kg) and timing of ICG administration (∼20-60 seconds preassessment) and best camera angle (61-90o) and target-to-tissue distance (20-30 cm). However, consensus also was reached that camera angle and distance can vary, depending on the make of camera, and that further research is necessary to technically optimize this imaging tool. The experts also agreed that ambient light, patient body temperature, and vasopressor use impact perfusion assessments. CONCLUSION: ICG-A aids perfusion assessments during plastic and reconstructive surgery and should no longer be considered experimental. It has become an important surgical tool.


Assuntos
Neoplasias da Mama , Procedimentos de Cirurgia Plástica , Humanos , Feminino , Verde de Indocianina , Mastectomia , Procedimentos de Cirurgia Plástica/métodos , Angiografia/métodos , Perfusão
10.
Front Oncol ; 12: 989231, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36185209

RESUMO

Background: A robotic deep inferior epigastric perforator (DIEP) flap created through a totally extraperitoneal approach minimizes violation of the donor site, which may lead to postoperative pain reduction and rapid recovery. The authors compared the clinical outcomes of robotic and conventional DIEP flap breast reconstructions. Methods: Data from consecutive patients who underwent mastectomy with DIEP flaps for breast reconstruction between July 2017 and January 2021 were retrospectively reviewed. Patients were divided into robotic and conventional DIEP groups, and the two groups were matched using the inverse probability of treatment weighting method. They were compared based on the reconstruction time, drainage amount, postoperative pain, rescue analgesics, hospital stay, complications, and BREAST-Q scores. Results: After matching, a dataset of 207 patients was formed, including 21 patients in the robotic DIEP group and 186 patients in the conventional DIEP group. The mean reconstruction time was longer in the robotic DIEP group than in the conventional DIEP group (P<0.001). In the robotic group, pain intensity during the postoperative 6-24 hours was significantly reduced (P=0.001) with less use of fentanyl (P=0.003) compared to the conventional DIEP group. The mean length of hospital stay for the robotic DIEP group was shorter than that for conventional DIEP (P=0.002). BREAST-Q scores indicated a higher level of the abdominal physical well-being domain in the robotic group (P=0.020). Complication rates were comparable between the two groups. Conclusions: This study suggests that a robotic DIEP flap offers enhanced postoperative recovery, accompanied by a reduction in postoperative pain and hospital stay.

12.
J Plast Reconstr Aesthet Surg ; 75(6): 1878-1885, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35125304

RESUMO

Insufficient and inconsistent survival is a significant shortcoming of fat grafts. Reportedly, megestrol acetate (MA) could induce proliferation, migration, and adipogenic differentiation of adipose-derived stem cells in vitro. Thus, we tested whether MA could promote fat graft survival in a rat model. Twenty-eight Sprague-Dawley rats (8 weeks old, male) were divided into two groups: experimental (MA group, n = 14) and control (n = 14). The inguinal fat pad (1 g) was extracted en bloc and re-implanted under the scalp in both groups. MA (100 mg/kg/day) was administered orally for 14 postoperative days in the experimental group. After 6 weeks, the volume and weight of the grafted fat were measured. Histologic examination with hematoxylin and eosin (HE) and real-time polymerase chain reaction (PCR) for vascular endothelial growth factor (VEGF), fibroblast growth factor 2 (FGF2), and CCAAT/enhancer-binding protein alpha (C/EBP-α) were performed. Perilipin staining was performed to check the viability of grafted fat. Graft fat volume was greater in the MA group, compared with that in the control (P = 0.023). The MA group also had more viable cells, including more adipocytes, and less fibrosis or vacuoles than the control on HE and perilipin staining. MA upregulated the expression of FGF2 (P<0.001), VEGF (P = 0.008), and C/EBP-α (P = 0.002) at the second postoperative week. MA increased survival of grafted fat in an animal model. Increased vascularization and adipogenesis were related to these results. Further human clinical trials are necessary to evaluate adjunctive oral administration of MA after fat grafting to promote graft survival.


Assuntos
Sobrevivência de Enxerto , Fator A de Crescimento do Endotélio Vascular , Tecido Adiposo/transplante , Administração Oral , Animais , Fator 2 de Crescimento de Fibroblastos , Humanos , Masculino , Acetato de Megestrol , Perilipinas , Ratos , Ratos Sprague-Dawley
13.
Arch Plast Surg ; 49(1): 34-38, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35086306

RESUMO

The deep inferior epigastric perforator (DIEP) flap has been widely used for autologous breast reconstruction after mastectomy. In the conventional surgical method, a long incision is needed at the anterior fascia of the rectus abdominis muscle to obtain sufficient pedicle length; this may increase the risk of incisional hernia. To shorten the incision, several trials have investigated the use of endoscopic/robotic devices for pedicle harvest; however, making multiple additional incisions for port insertion and operating in the intraperitoneal field were inevitable. Here, we describe the first case, in which a DIEP free flap was successfully made using the da Vinci SP model. Our findings can help surgeons perform operations in smaller fields with a single port in the extraperitoneal space. Moreover, this method is expected to lead to fewer donor-related complications and faster healing.

14.
Arch Plast Surg ; 48(6): 577-582, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34818702

RESUMO

Robot-assisted surgery is evolving to incorporate a higher number of minimally invasive techniques. There is a growing interest in robotic breast reconstruction that uses autologous tissue. Since a traditional latissimus dorsi (LD) flap leads to a long donor scar, which can be an unpleasant burden to patients, there have been many attempts to decrease the scar length using minimally invasive approaches. This study presents the case of a patient who underwent a robot-assisted nipple-sparing mastectomy followed by immediate breast reconstruction with an LD flap using a single-port robotic surgery system. With the assistance of a single-port robot, a simple docking process using a short and less visible incision is possible. Compared to multiport surgery systems, single-port robots can reduce the possibility of collision between robotic arms and provide a clear view of the medial border of the LD where the curvature of the back restricts the visual field. We recommend the use of single-port robots as a minimally invasive approach for harvesting LD flaps.

15.
Arch Plast Surg ; 48(6): 583-589, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34818703

RESUMO

BACKGROUND: In prosthesis-based breast reconstruction patients, the drain tends to be kept in place longer than in patients who undergo only mastectomy. Postoperative arm exercise also increases the drainage volume. However, to preserve shoulder function, early exercise is recommended. In this study, we investigated the effect of early exercise on the total drainage volume and drain duration in these patients. METHODS: We designed a prospective randomized trial involving 56 patients who underwent immediate breast reconstruction following mastectomy using tissue expanders. In each group, the patients were randomized either to perform early arm exercises using specific shoulder movement guidelines 2 days after surgery or to restrict arm movement above the shoulder height until drain removal. The drain duration and the total amount of drainage were the primary endpoints. RESULTS: There were no significant differences in age, height, weight, body mass index, or mastectomy specimen weight between the two groups. The total amount of drainage was 1,497 mL in the early exercise group and 1,336 mL in the exercise restriction group. The duration until complete removal of the drains was 19.71 days in the early exercise group and 17.11 days in the exercise restriction group. CONCLUSIONS: Exercise restriction after breast reconstruction did not lead to a significant difference in the drainage volume or the average time until drain removal. Thus, early exercise is recommended for improved shoulder mobility postoperatively. More long-term studies are needed to determine the effect of early exercise on shoulder mobility in prosthesis-based breast reconstruction patients.

16.
Sci Rep ; 11(1): 21032, 2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34702866

RESUMO

Robotic nipple-sparing mastectomy (RNSM) provides better cosmetic outcomes and improves the quality of life of women with breast cancer. However, this has not been widely adapted due to the lack of well-structured training programs. The present study aimed to report the establishment of cadaveric and animal skill laboratory training programs for RNSM and the participants' perception on the training programs. We performed 24 RNSMs using 11 cadavers and one porcine model. Then, the skill laboratory characteristics were reviewed. Five trainers and 10 trainees participated in the programs. The first four cadaveric RNSMs with latissimus dorsi flaps and implants were performed using the da Vinci Si® system. We performed 14 and six RNSMs using the Xi® and SP® systems, respectively. The scores for questionnaires on the satisfaction with the training consisted of the trainees' perceived goals in attending the course, teaching/learning environment, and teaching staff performance. The scores were excellent. Cadaveric or porcine RNSM skill laboratory training may be essential programs that can provide safe and efficient training.


Assuntos
Mastectomia , Procedimentos Cirúrgicos Robóticos , Retalhos Cirúrgicos , Suínos , Animais , Neoplasias da Mama/cirurgia , Feminino , Humanos , Procedimentos Cirúrgicos Robóticos/educação , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos
17.
Front Physiol ; 12: 638448, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34366876

RESUMO

Background: Adipose-derived stem cells (ASCs) are multipotent mesenchymal stem cells characterized by their strong regenerative potential and low oxygen consumption. Macrophage migration inhibitory factor (MIF) is a multifunctional chemokine-like cytokine that is involved in tissue hypoxia. MIF is not only a major immunomodulator but also is highly expressed in adipose tissue such as subcutaneous adipose tissue of chronic non-healing wounds. In the present study, we investigated the effect of hypoxia on MIF in ASCs isolated from healthy versus inflamed adipose tissue. Methods: Human ASCs were harvested from 17 patients (11 healthy adipose tissue samples, six specimens from chronic non-healing wounds). ASCs were treated in a hypoxia chamber at <1% oxygen. ASC viability, MIF secretion as well as expression levels of MIF, its receptor CD74, hypoxia-inducible transcription factor-1α (HIF-1α) and activation of the AKT and ERK signaling pathways were analyzed. The effect of recombinant MIF on the viability of ASCs was determined. Finally, the effect of MIF on the viability and production capacity of ASCs to produce the inflammatory cytokines tumor necrosis factor (TNF), interleukin (IL)-6, and IL-1ß was determined upon treatment with recombinant MIF and/or a blocking MIF antibody. Results: Hypoxic treatment inhibited proliferation of ASCs derived from healthy or chronic non-healing wounds. ASCs from healthy adipose tissue samples were characterized by a low degree of MIF secretion during hypoxic challenge. In contrast, in ASCs from adipose tissue samples of chronic non-healing wounds, secretion and expression of MIF and CD74 expression were significantly elevated under hypoxia. This was accompanied by enhanced ERK signaling, while AKT signaling was not altered. Recombinant MIF did stimulate HIF-1α expression under hypoxia as well as AKT and ERK phosphorylation, while no effect on ASC viability was observed. Recombinant MIF significantly reduced the secretion of IL-1ß under hypoxia and normoxia, and neutralizing MIF-antibodies diminished TNF-α and IL-1ß release in hypoxic ASCs. Conclusions: Collectively, MIF did not affect the viability of ASCs from neither healthy donor site nor chronic wounds. Our results, however, suggest that MIF has an impact on the wound environment by modulating inflammatory factors such as IL-1ß.

18.
Aging (Albany NY) ; 13(16): 19978-19995, 2021 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-34404755

RESUMO

Dermal papilla cells (DPCs) tend to aggregate both in vitro and in vivo, which increases the hair inductivity of DPCs. However, the underlying mechanism of spheroid formation is unknown. We investigated whether collagen expression in human DPCs (hDPCs) is involved in the spheroid formation and hair inductivity of hDPCs and further examined the underlying molecular mechanism of collagen upregulation. The expression of diverse collagens, such as COL13A1 and COL15A1, was upregulated in three dimensional (3D)-cultured or intact DPCs, compared to 2D-cultured hDPCs. This collagen expression was a downregulated in aged hair follicle, and aged DPCs were difficult to aggregate. Blocking of COL13A1 and COL15A1 by small interfering RNA reduced aggregation, while induced senescence of hDPCs in vitro. Further, transforming growth factor-ß2 (TGF-ß2) expression decreases with aging, and is involved in regulating the expression of COL13A1 and COL15A1. Addition of recombinant TGF-ß2 delayed cellular senescence, and recovered spheroid formation in aged hDPCs by upregulating collagen levels. On the contrary, knock-out of TGF-ß2 induced the aging of DPCs, and inhibited spheroid formation. These results suggested that COL13A1 and COL15A1 expression is downregulated with aging in DPCs, and upregulation of collagen by TGF-ß2 induces the spheroid formation of DPCs. Therefore, TGF-ß2 supplement in DPC culture medium could enhance the maintenance and hair inductivity of DPCs.


Assuntos
Envelhecimento/metabolismo , Colágeno Tipo XIII/metabolismo , Colágeno/metabolismo , Derme/metabolismo , Folículo Piloso/metabolismo , Esferoides Celulares/metabolismo , Fator de Crescimento Transformador beta2/metabolismo , Envelhecimento/genética , Proliferação de Células , Células Cultivadas , Senescência Celular , Colágeno/genética , Colágeno Tipo XIII/genética , Derme/citologia , Folículo Piloso/citologia , Humanos , Esferoides Celulares/citologia , Fator de Crescimento Transformador beta2/genética
19.
Plast Reconstr Surg ; 148(2): 304-307, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34398082

RESUMO

SUMMARY: Deep inferior epigastric artery perforator (DIEP) flap surgery is one of the most common techniques for breast reconstruction using abdominal tissue. Although the DIEP flap reduces donor-site morbidity when compared with the conventional free transverse rectus abdominis musculocutaneous flap, violation of the anterior rectus sheath, rectus muscle, and motor nerves cannot be avoided. To further minimize tissue damage in the donor site, the use of a surgical robotic system for DIEP flap harvest with a totally extraperitoneal approach has been suggested. This totally extraperitoneal approach has a long learning curve because of the narrow preperitoneal space and the difficulty of converting a potential space to an actual space. Thus, the authors suggest a single-port robotic system optimized for narrow surgical spaces as a feasible option for DIEP flap harvest by a totally extraperitoneal approach, which has a shorter learning curve.


Assuntos
Retalho Perfurante/transplante , Reto do Abdome/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Coleta de Tecidos e Órgãos/métodos , Sítio Doador de Transplante/cirurgia , Estudos de Viabilidade , Humanos , Curva de Aprendizado , Mamoplastia/métodos , Procedimentos Cirúrgicos Robóticos/educação , Procedimentos Cirúrgicos Robóticos/instrumentação , Coleta de Tecidos e Órgãos/educação , Coleta de Tecidos e Órgãos/instrumentação
20.
Arch Plast Surg ; 48(2): 194-198, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33765738

RESUMO

Robot-assisted nipple-sparing mastectomy with immediate reconstruction is currently performed in an attempt to seek smaller and indistinct incisions. Robotic surgery system has been evolving under the concept of minimal invasive technique which is a recent trend in surgery. One of the latest version is the da Vinci SP Surgical System (Intuitive Surgical). In this report, we will share our experiences. Two patients underwent robot-assisted nipple-sparing mastectomy, each followed by immediate robot-assisted expander insertion and prepectoral direct-to-implant breast reconstruction, respectively. There was no open conversion or major postoperative complication. One patient experienced mild infection, which was resolved by intravenous antibiotic treatment. Simple docking process, multi-joint instruments, and third-arm functionality are among the new surgical system's advantages. The present cases suggest that robot-assisted nipple-sparing mastectomy with immediate reconstruction using the da Vinci SP Surgical System is feasible and safe. The promising features and potential application of da Vinci SP in breast reconstruction need further study.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA