Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(3): e25158, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38322892

RESUMO

Objective: This study aimed to assess the current status of carcinoembryonic antigen (CEA) detection. We evaluated the correlation, consistency, and comparability of CEA results among six automated immunoassays, and combined with the results of CEA trueness verification of the Beijing Center for Clinical Laboratories (BCCL) for further analysis. Methods: Abbott Architect i2000, Beckman DxI800, Roche Cobas E601, Diasorin Liaison XL, Maccura IS1200, and Autolumo A2000 were used to detect 40 individual serum CEA samples. Taking the optimal analytical quality specifications calculated from data on biological variation as the evaluation criterion. Passing-Bablok regression and Bland-Altman analysis were performed between each assay and all-assays median values to evaluate the correlation and relative difference. The concordance correlation coefficient (CCC) was used for consistency analysis. Additionally, the trueness verification program used samples at three concentration levels to assess the bias, coefficient of variation (CV), and total error (TE) between the average measured values and the target value. Results: The Spearman's rank correlation coefficient (rs) was ≥0.996 and the CCC ranged between 0.9448 and 0.9990 for each assay vs. all-assays median. Considering the all-assays median value of each sample as a reference, there were proportional and systematic differences according to the Passing-bablok regression analysis. The relative difference of the four assays (Abbott Architect i2000, Autolumo A2000, Diasorin Liaison XL, and Maccura IS1200) met the optimal analytical quality specifications. On the other hand, Beckman DxI800 (13.2 %) and Roche Cobas E601 (-9.0 %) were only able to fulfill the desirable analytical quality specifications. The average pass rates for bias, CV, and TE of the trueness verification program were 80 %, 98 %, and 96 %, respectively. Conclusions: The six automated immunoassays vs. all-assays median have a good correlation in CEA detection. However, there is a lack of comparability of CEA results. Further improvements are needed in harmonization among CEA detections.

2.
Clin Chim Acta ; 552: 117701, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38081446

RESUMO

AIMS: We analyzed the differentially expressed proteins (DEPs) in serum and urine in order to provide new potential biomarkers for MM. METHODS: Data-Independent Acquisition-based proteomics of serum and urine was performed to identify potential biomarkers for MM patients. Then we performed Western Blotting (WB), ELISA along with their ROC curve analysis to confirm DEPs. RESULTS: A total of 1653 proteins in serum and 4519 proteins in urine were identified using Data-Dependent Acquisition method. VCP was the only protein that showed significant differences in different comparison groups in both serum and urine. Pathway analysis revealed that protein processing in the endoplasmic reticulum was the most relevant pathway associated with MM. Furthermore, the increased expression of HSP90B1, VCP, CTSA, HYOU1, PDIA4, and RAB7A was detected by WB. The results of ELISA indicated that a combination of VCP and CTSA provided a high area under curve (AUC) value of 0.883 (95 % CI, 0.769-0.997, p < 0.001) to diagnose NDMM. The combination of VCP, CTSA, ALB, and HGB exhibited better performance (AUC = 0.981), with 100 % specificity and 86.7 % sensitivity. CONCLUSION: These findings suggest VCP and CTSA exhibit potential as biomarkers for MM, which may be helpful in the molecular mechanisms and pathogenesis upon further investigation.


Assuntos
Mieloma Múltiplo , Humanos , Biomarcadores , Proteínas , Proteômica , Curva ROC , Proteína com Valosina
3.
J Inflamm Res ; 16: 5779-5789, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38076333

RESUMO

Purpose: Outcomes after autologous stem cell transplantation (ASCT) are quite variable and difficult to predict. Second-generation flow, second-generation sequencing, and other tests are invasive and expensive for patients. In this study, we aimed to analyze laboratory data before and after transplantation to look for laboratory indicators that could predict disease progression in patients with newly diagnosed multiple myeloma (NDMM) patients underwent ASCT. Patients and Methods: Standard complete blood count (CBC) parameters, clinical biochemical, and immunological indicators on day -5 and day 90 after ASCT were obtained. Receiver-operating characteristic (ROC) curve was used to determine the cutoff values, we evaluated the predictive abilities of laboratory parameters for progression-free survival (PFS). Univariate and multivariate analyses were performed to evaluate the prognostic significance of variables associated with the PFS of 166 NDMM who underwent ASCT. Results: At day-5, a low absolute monocyte count (AMC, p=0.001), systemic inflammation response index<1.56 (SIRI, P=0.03), serum calcium (p=0.02), and albumin (p=0.006) can predict for superior PFS. At Day +90, a high absolute neutrophil count (ANC, p = 0.008) and lymphocyte-to-monocyte ratio (LMR, p = 0.02), a low neutrophil-to-lymphocyte ratio (NLR, p =0.02) and SIRI<0.41 (p=0.02) predicted for superior PFS. Conclusion: There are inflammation-related indicators derived from peripheral blood cell count (WBCC) - ANC, NLR, SIRI, and LMR - which can serve as potential biomarkers for predicting PFS of NDMM patients underwent ASCT.

4.
Food Nutr Res ; 672023.
Artigo em Inglês | MEDLINE | ID: mdl-37533448

RESUMO

Background: Recent studies from targeted and untargeted metabolomics have consistently revealed that diet-related metabolites, including carnitine (C0), several species of acylcarnitines (AcyCNs), amino acids, ceramides, and lysophosphatidylcholines (LPCs) may serve as potential multiple myeloma (MM) biomarkers. However, most of these approaches had some intrinsic limitations, namely low reproducibility and compromising the accuracy of the results. Objective: This study developed and validated a precise, efficient, and reliable liquid chromatography tandem mass spectrometric (LC-MS/MS) method for measuring these 28 metabolic risk factors in human serum. Design: This method employed isopropanol to extract the metabolites from serum, gradient elution on a hydrophilic interaction liquid chromatographic column (HILIC) for chromatographic separation, and multiple reaction monitor (MRM) mode with positive electrospray ionization (ESI) for mass spectrometric detection. Results: The correlation coefficients of linear response for this method were more than 0.9984. Analytical recoveries ranged from 91.3 to 106.3%, averaging 99.5%. The intra-run and total coefficients of variation were 1.1-5.9% and 2.0-9.6%, respectively. We have simultaneously determined the serological levels of C0, several subclasses of AcyCNs, amino acids, ceramides, and LPCs within 15 min for the first time. Conclusion: The established LC-MS/MS method was accurate, sensitive, efficient, and could be valuable in providing insights into the association between diet patterns and MM disease and added value in further clinical research.

5.
J Clin Lab Anal ; 37(11-12): e24936, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37395487

RESUMO

BACKGROUND: In this study, we explored the commutability of reference materials (RMs) for carcinoembryonic antigen (CEA), selected the appropriate diluent matrix of the first International Reference Preparation (IRP) 73/601 of the World Health Organization (WHO 73/601) for CEA, and improved the comparability of CEA measurement results among different assay systems. METHODS: Forty serum samples were divided into five aliquots. WHO 73/601 was diluted into nine concentrations using five diluents with different components, and the candidate RMs for CEA at five concentrations (C1-C5) were prepared by the Beijing Clinical Laboratory Center (BCCL). The samples were analyzed via five automated CEA immunoassays. RESULTS: Carcinoembryonic antigen candidate RMs were commutable among all immunoassays based on the CLSI approach and among 7 of 10 assay combinations based on the IFCC approach. WHO 73/601 diluted in phosphate-buffered saline (PBS) was commutable among all assays based on the CLSI approach and among 5 of 10 pairwise comparisons based on the IFCC approach with correction of bias at diluted concentrations, except for the lowest concentration, which had the smallest variation among systems. The median percentage biases among assays were decreased after calibration. CONCLUSION: The BCCL candidate RMs (C2-C5) for CEA were commutable among all immunoassays. WHO 73/601 RMs diluted in a PBS buffer matrix were selected as common calibrators for five immunoassays, which reduced bias, thereby effectively improving the harmonization of CEA detection; therefore, they could be used to assign values to CEA candidate RMs developed by BCCL. Our findings promote the harmonization of CEA detection in immunoassays.


Assuntos
Antígeno Carcinoembrionário , Serviços de Laboratório Clínico , Humanos , Imunoensaio , Laboratórios , Laboratórios Clínicos , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA