Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
J Interv Card Electrophysiol ; 67(2): 273-283, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37103590

RESUMO

BACKGROUND: Posterior wall (PW) isolation is an important adjunctive ablation target in patients with non-paroxysmal atrial fibrillation (AF). Traditionally performed with point-by-point radiofrequency (RF) ablation, PW isolation has also been performed with different cryoballoon technologies. We aimed at assessing the feasibility of PW isolation with the novel RF balloon catheter Heliostar™ (Biosense Webster, CA, USA). METHODS: We prospectively enrolled 32 consecutive patients with persistent AF scheduled for first-time ablation with the Heliostar™ device. Procedural data were compared with those from 96 consecutive persistent AF patients undergoing pulmonary vein (PV) plus PW isolation with a cryoballoon device. The ratio RF balloon/cryoballoon was 1:3 for each operator involved in the study, aiming at avoiding any imbalance related to different experience. RESULTS: Single-shot PV isolation was documented in a significantly higher number of cases with the RF balloon technology compared to cryoballoon ablation (89.8% vs. 81.0%; p = 0.02, respectively). PW isolation was achieved with a similar number of balloon applications between the two groups (11 ± 4 with the RF balloon versus 11 ± 2 with the cryoballoon; p = 0.16), but in a significantly shorter time among RF balloon patients (228 ± 72 s versus 1274 ± 277 s with cryoballoon; p < 0.001). Primary safety endpoint occurred in none of the RF balloon patients versus 5 (5.2%) patients in the cryoballoon group (p = 0.33). Primary efficacy endpoint was achieved in all (100%) RF balloon patients versus 93 (96.9%) cryoballoon ones (p = 0.57). Oesophageal endoscopy did not show any signs of thermal lesions in RF balloon patients with luminal temperature rise. CONCLUSIONS: RF balloon-based PW isolation was safe and promoted shorter procedure times compared to similar cryoballoon-based ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Criocirurgia/métodos , Estudos de Viabilidade , Resultado do Tratamento , Ablação por Cateter/métodos , Recidiva , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Catéteres
2.
J Cardiovasc Med (Hagerstown) ; 24(7): 441-452, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37285275

RESUMO

BACKGROUND: In terms of safety and efficacy, cryoballoon ablation (CB-A) has become a valid option for achieving pulmonary vein isolation (PVI) in patients affected by symptomatic atrial fibrillation. However, CB-A data in octogenarians are still scarce and limited to single-centre experiences. The present multicentre study aimed to compare the outcomes and complications of index CB-A in patients older than 80 years with a cohort of younger patients. METHODS AND RESULTS: We retrospectively enrolled 97 consecutive patients aged ≥80 years who underwent PVI using the second-generation CB-A. This group was compared with a younger cohort of patients using a 1:1 propensity score matching. After the matching, 70 patients from the elderly group were analysed and compared with 70 younger patients (control group). The mean age was 81.4 ±â€Š1.9 years among octogenarians and 65.2 ±â€Š10.2 years in the younger cohort. The global success rate after a median follow-up of 23 [18-32.5] months was 60.0% in the elderly group and 71.4% in the control group (P = 0.17). Phrenic nerve palsy was the most common complication occurring in a total of 11 patients (7.9%): in 6 (8.6%) patients in the elderly group and in 5 patients (7.1%) in the younger group (P = 0.51). Only two (1.4%) major complications occurred: one (1.4%) femoral artery pseudoaneurysm in the control group, which resolved with a tight groin bandage, and one (1.4%) case of urosepsis in the elderly group. Arrhythmia recurrence during the blanking period and the need for electrical cardioversion to restore sinus rhythm after PVI were found to be the only independent predictors of late arrhythmia relapses. CONCLUSIONS: The present study showed that CB-A PVI is as feasible, safe and effective among appropriately selected octogenarians as it is in younger patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Idoso de 80 Anos ou mais , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Octogenários , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Estudos Retrospectivos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Recidiva , Veias Pulmonares/cirurgia
3.
Eur Heart J Case Rep ; 7(5): ytad227, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37181468

RESUMO

Background: Non-bacterial thrombotic endocarditis (NBTE) is a rare condition characterized by sterile thrombi on undamaged valves. We herein report a case of NBTE involving the Chiari's network and the mitral valve, related to a metastatic cancer, and occurring under non-vitamin K antagonist oral anticoagulant (NOAC). Case summary: A 74-year-old patient with metastatic pulmonary cancer was diagnosed with a right atrium mass during pre-treatment cardiovascular check-up. Transoesophageal echocardiography and cardiac magnetic resonance concluded that the mass was a Chiari's network. Two months later, the patient was admitted for a pulmonary embolism and started rivaroxaban. At 1-month follow-up, the patient underwent a new echocardiography, which showed an increased size of the right atrium mass and the presence of two new masses on the mitral valve. She suffered an ischaemic stroke. Infectious work-up was negative. Coagulation factor VIII was 419%. A NBTE with Chiari's network thrombosis and mitral valve involvement was suspected in the setting of a hypercoagulable state related to the active cancer, and intravenous heparin was started, bridged to vitamin K antagonist (VKA) after 3 weeks. All the lesions were fully resolved on follow-up echocardiography at 6 weeks. Discussion: This case highlights an atypical association of thrombosis on right and left heart chamber with systemic and pulmonary embolism, related to a hypercoagulable state. Chiari's network is an embryonic remnant with no clinical significance and is exceptionally thrombosed. Failure of treatment by NOAC highlights the complexity of cancer-related thrombosis, particularly in NBTE, and the necessity of heparin and VKA in our case.

4.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38245007

RESUMO

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
5.
Am J Cardiol ; 181: 45-54, 2022 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-35973836

RESUMO

Management of ventricular arrhythmias (VAs) beyond implantable cardioverter-defibrillator positioning in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) is challenging. Catheter ablation of the ventricular substrate often requires a combination of endocardial and epicardial approaches, with disappointing outcomes due to the progressive nature of the disease. We report the Universitair Ziekenhuis Brussel experience through a case series of 16 patients with drug-refractory ARVC, who have undergone endocardial and/or epicardial catheter ablation of VAs with a thoracoscopic hybrid-approach. After a mean follow-up time of 5.16 years (SD 2.9 years) from the first hybrid-approach ablation, VA recurrence was observed in 5 patients (31.25%): among these, patients 4 patients (80%) received a previous ablation and 1 of 11 patients (9.09%) who had a hybrid ablation as first approach had a VA recurrence (80% vs 9.09%; log-rank p = 0.04). Despite the recurrence rate of arrhythmic events, all patients had a significant reduction in the arrhythmic burden after ablation, with a mean of 4.65 years (SD 2.9 years) of freedom from clinically significant arrhythmias, defined as symptomatic VAs or implantable cardioverter-defibrillator-delivered therapies. In conclusion, our case series confirms that management of VAs in patients with ARVC is difficult because patients do not always respond to antiarrhythmic medications and can require multiple invasive procedures. A multidisciplinary approach involving cardiologists, cardiac surgeons, and cardiac electrophysiologists, together with recent cardiac mapping techniques and ablation tools, might mitigate these difficulties and improve outcomes.


Assuntos
Displasia Arritmogênica Ventricular Direita , Ablação por Cateter , Taquicardia Ventricular , Displasia Arritmogênica Ventricular Direita/cirurgia , Ablação por Cateter/métodos , Humanos , Recidiva , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
6.
J Interv Card Electrophysiol ; 65(2): 559-571, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35869379

RESUMO

BACKGROUND: Cryoballoon technology (CB-A) has become a cornerstone of atrial fibrillation (AF) ablation in terms of safety and efficacy. Data regarding CB-A in octogenarians are still scarce and limited to single center experiences. The present study sought to analyze the performances of index CB-A in patients older than 80 years-old referring to 3 high-volume European centers. METHODS AND RESULTS: We retrospectively enrolled 95 patients with a median age of 81 [80, 83] years. 62 (65.3%) patients presented with paroxysmal AF and 33 (33.7%) with persistent AF. Mean procedure and fluoroscopy times were 73.8 ± 25.2 and 15.3 ± 7.5 min, respectively. At 12 months and 24 months of follow-up, the overall freedom from AF was 81.1% and 66.6%, respectively. When divided for AF type, freedom from AF was higher in patients with paroxysmal AF (p = 0.007). Cryoballoon ablation was able to significantly improve AF-related symptoms as proven by the significant decrease in EHRA score during the follow-up (p < 0.0001). Phrenic nerve palsy occurred in 8 (8.5%) patients and always resolved during the procedure without affecting procedural outcome. Two major complications occurred (2.1%); one patient experienced pneumonia, successfully treated with antibiotics and non-invasive mechanical ventilation, the latter one experienced acute kidney failure secondary to urosepsis successfully treated by renal replacement therapy. CONCLUSIONS: The present study showed that CB-A is a feasible and effective procedure among octogenarians with a low complication rate. Contemporarily, CB-A can help to alleviate arrhythmia-related symptoms also among this group of subjects.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Criocirurgia/métodos , Estudos Retrospectivos , Octogenários , Resultado do Tratamento , Recidiva
7.
Pacing Clin Electrophysiol ; 45(5): 605-611, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35352363

RESUMO

BACKGROUND: Left atrial posterior wall isolation (LAPWI) is often performed in addition to pulmonary vein isolation (PVI) in the setting of persistent atrial fibrillation (AF) ablation. The aim of this study was to evaluate the feasibility and safety of a new cryoballoon ablation system in achieving PVI + LAPWI isolation. METHODS: The study was a prospective, non-randomized, single center study. Forty consecutive patients, undergoing PVI + LAPWI with the novel POLARx™, were compared to 40 consecutive patients who underwent the same procedure with the established Arctic Front Advance PRO™. RESULTS: Acute isolation was achieved in all PVs in both groups and left posterior wall isolation (LAPWI) was achieved in 38 patients (95%) in the POLARx group and in 36 patients (90%) in Arctic Front group. Procedural outcomes were similar between both groups, except for lower temperatures during cryoenergy in the POLARx group, for both pulmonary vein isolation (PVI) and LAPWI. CONCLUSION: LAPWI + PVI with the novel POLARx™ Cryoballoon is feasible and safe; the results are comparable with the Arctic Front Advance PRO™ system.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Estudos de Viabilidade , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Tecnologia , Resultado do Tratamento
8.
Artigo em Inglês | MEDLINE | ID: mdl-35224625

RESUMO

A 33-year-old woman with Sick Sinus Node syndrome and persistent atrial fibrillation underwent a Maze IV procedure in order treat atrial fibrillation and concomitant atrial epicardial implantation of a leadless pacemaker to manage her sinus node insufficiency. Last option has been chosen due to rare pocket complication after previous classic dual-chamber pacemaker implantation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dermatite , Marca-Passo Artificial , Adulto , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Estimulação Cardíaca Artificial/efeitos adversos , Dermatite/complicações , Dermatite/terapia , Eletrônica , Feminino , Humanos , Marca-Passo Artificial/efeitos adversos , Síndrome do Nó Sinusal/complicações , Síndrome do Nó Sinusal/terapia
9.
Pacing Clin Electrophysiol ; 44(12): 2075-2083, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34773413

RESUMO

BACKGROUND: Pulmonary vein (PV) isolation is an established treatment for paroxysmal drug-refractory atrial fibrillation (AF). High parasympathetic tone and reconnection of PVs have demonstrated to be possible culprits of AF recurrence after ablation. Our aim was to investigate the association between parasympathetic tone and reconnected PVs in patients with paroxysmal AF. METHODS: Consecutive patients who underwent a redo catheter ablation procedure for atrial tachyarrhythmia recurrence by means of 3D electroanatomic mapping with documentation of presence or absence of PVs reconnection following an initial procedure of cryoballoon (CB) ablation for symptomatic drug-refractory paroxysmal AF were screened for the study. RESULTS: A total of 92 patients were included, of whom 50 (54.35%) were males. Reconnected PVs were found in 64 (69%) patients. PVs reconnection could be predicted by DC (C-statistic = .770), by SDNNI (C-statistic = .714) and by absolute VLF power (C-statistic = .722), while right-sided PVs reconnection could be better predicted by DC (C-statistic = .848) and by SDNNI (C-statistic = .761). In multivariate binary logistic regression analysis, a DC value ≥6.45 ms and an absolute VLF power value ≥160 ms2 were associated with three times and five times higher odds of PVs reconnection, respectively. On a vein-per-vein analysis, absolute VLF power ≥160 ms2 was associated with three times higher odds, while reaching of -40°C within 60 s was associated with three times lower odds of PVs reconnection. CONCLUSION: High parasympathetic tonus accurately predicts PVs reconnection. On a vein-per-vein analysis, parasympathetic markers along with biophysical parameters predicted PVs reconnection. On a case-by-case analysis, parasympathetic markers were the only predictors of PVs reconnection, thus being a robust PVs reconnection prediction tool.


Assuntos
Fibrilação Atrial/cirurgia , Sistema Nervoso Autônomo/fisiopatologia , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Nervo Vago/fisiopatologia , Adulto , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação
11.
Herzschrittmacherther Elektrophysiol ; 32(3): 323-329, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34228177

RESUMO

Achieving the goal management of some arrhythmic syndromes can be challenging; medical treatment for inappropriate sinus tachycardia (IST) and postural orthostatic tachycardia syndrome (POTS) may be ineffective, necessitating multidisciplinary team treatment. Implantable defibrillator devices (ICDs), along with anti-arrhythmic drugs (AADs), remain the first-line treatment for primary electrical diseases that pose a risk of sudden cardiac death (SCD). Ablation of the arrhythmogenic substrate is not always suggested in patients with these pathologies, but it may be a valuable support for reducing arrhythmic burden, improving quality of life, and treating pathologies that are resistant to pharmacological treatment; however, this option is not often considered due to the potential risks associated with an invasive approach. Minimally invasive hybrid ablation in these syndromes, such as a hybrid thoracoscopic approach and the use of non-invasive mapping systems, reduces post-surgery complications and ensures the best possible outcome for the patient.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Síndrome da Taquicardia Postural Ortostática , Morte Súbita Cardíaca , Humanos , Síndrome da Taquicardia Postural Ortostática/diagnóstico , Síndrome da Taquicardia Postural Ortostática/terapia , Qualidade de Vida , Taquicardia Sinusal/cirurgia , Taquicardia Sinusal/terapia
13.
Eur J Cardiothorac Surg ; 53(4): 700-707, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29438530

RESUMO

Hypertrophic cardiomyopathy is the most common genetic cardiovascular disorder and is associated with symptoms of heart failure and increased risk of sudden cardiac death. The most common condition is obstruction of the left ventricular outflow tract. Surgical septal myectomy and alcohol septal ablation are the 2 accepted modes of septal reduction therapy and are indicated when there are advanced symptoms and a peak left ventricular outflow gradient ≥50 mmHg. Advantages of alcohol septal ablation are limited groin approach, reduction of obstruction of the left ventricular outflow tract and functional improvement, but there are higher chances for intracardiac device implantation and residual obstruction. Septal myectomy offers very low mortality, absolute and immediate resolution of obstruction of the left ventricular outflow tract and survival comparative to a matched general population with almost negligible residual obstruction. It is recommended that patients with obstructive hypertrophic cardiomyopathy should be treated at experienced centres.


Assuntos
Cardiomiopatia Hipertrófica/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Septos Cardíacos/cirurgia , Humanos , Resultado do Tratamento
15.
Indian Pacing Electrophysiol J ; 15(4): 220-3, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26937125

RESUMO

A 15-year-old female with WPW syndrome and normal heart underwent an electrophysiology study for paroxysmal palpitations and syncope. Intravenous adenosine produced an unexpected response of QRS changes and advanced AV block. During isoproteronol infusion, short-lasting and poorly tolerated wide QRS tachycardia was inducible, but pacing maneuvers were not feasible during tachycardia to determine its definitive mechanism. However, various electrophysiologic phenomena including adenosine response, junctional beats pattern, and multisite atrial pacing were helpful to overcome the diagnosis challenges. Finally, careful evaluation of tachycardia features and the comprehensive electrophysiology study were crucial to establish presence of unusual preexcitation variants, and thus to guide successful catheter ablation of the arrhythmic substrate.

16.
J Cardiovasc Med (Hagerstown) ; 15(3): 194-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23756414

RESUMO

AIMS: Cryoballoon ablation (CRAB) as a modality for pulmonary vein isolation (PVI) is increasingly being accepted. We aim to study the long-term durability of CRAB in atrial fibrillation. METHODS: The first 51 consecutive patients with documented paroxysmal atrial fibrillation(PAF) who underwent CRAB at our institute were considered. Forty patients formed the study group. Successful PVI was achieved in all the patients. Patients were evaluated with Holter ECG recordings at 1, 3, 6 and 12 months and subsequent follow-up was biannual and based on the clinical status and physician discretion whether symptoms occurred. For the study purpose, a baseline ECG, a 24-h Holter and clinical evaluation were performed in all patients at final follow-up. RESULTS: A large 28-mm cryoballoon (CB) was used in 38 patients (95%), and the small 23-mm CB in the remaining two individuals (2%). The freedom from atrial fibrillation off-antiarrhythmic drug treatment (AAD) after a single procedure at a mean follow-up of 36.6 ±â€Š4 months was 57.5% (23/40). Transient right phrenic nerve palsy was the most common complication. CONCLUSION: Single balloon size CRAB provides a durable atrial fibrillation-free-AAD-free survival in drug-resistant PAF patients over long-term follow-up with a success rate of 57.5% with a single procedure.


Assuntos
Fibrilação Atrial/cirurgia , Oclusão com Balão/métodos , Criocirurgia/métodos , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Oclusão com Balão/efeitos adversos , Criocirurgia/efeitos adversos , Resistência a Medicamentos , Eletrocardiografia Ambulatorial/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Resultado do Tratamento
17.
Europace ; 14(12): 1708-14, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22772051

RESUMO

AIMS: Cryoballoon ablation has proven very effective in achieving pulmonary vein isolation (PVI). The novel Achieve inner lumen mapping catheter designed to be used in conjunction with the cryoballoon, serves as both a guidewire and a mapping catheter. To our knowledge, this is the first study comparing the latter to verification of electrical isolation with the 'traditional' circular mapping catheter. METHODS AND RESULTS: We assigned 40 consecutive patients matched for age and left atrial diameter suffering of paroxysmal atrial fibrillation to cryoballoon PVI using either the circular mapping catheter or the Achieve as a mapping catheter. Duration of procedure as well as fluoroscopy times were significantly lower in the Achieve group than in the circular mapping catheter group (111 ± 14 min vs. 126 ± 13 min, P < 0.005 and 22 ± 5 min vs. 29 ± 4 min, P < 0.0001, respectively). There were no significant differences between both groups in terms of mean degree of occlusion, mean minimal temperatures, and PVI. Pulmonary vein isolation could be documented by real-time recordings in 55% of veins in the Achieve group with mean time to isolation of 65 ± 23 s. CONCLUSION: Cryoballoon ablation in conjunction with the novel Achieve is feasible, safe, and affords PVI in nearly all veins in similar proportions to the approach with the traditional guidewire. Furthermore, if compared to the procedure with the circular mapping catheter, cryoballoon ablation with the Achieve is significantly faster and associated to shorter fluoroscopy times.


Assuntos
Angioplastia com Balão/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Cateteres Cardíacos , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
18.
Europace ; 14(2): 197-203, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21937477

RESUMO

AIMS: Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice. Nowadays, catheter-based ablative approaches are mainly reserved for drug-refractory patients. However, the value of an ablative therapy as a first-line alternative remains elusive. The aim of our study was to analyse the acute procedural success and clinical outcome of patients with lone paroxysmal AF undergoing cryoballoon ablation (CBA) as first-line treatment. METHODS AND RESULTS: Eighteen individuals (mean age 44 ± 9 years, range 23-61 years, 15 males) with lone paroxysmal AF preferring a catheter-based treatment to drug treatment as first-line therapy were consecutively enrolled in our study. Mean left atrial size was 39 ± 4 mm and mean left ventricular ejection fraction 58 ± 3%. After a mean of 2.4 CBA (range 2-4) applications pulmonary vein (PV) isolation could be demonstrated in 70 (97%) PVs. Additional lesions with a focal ablation catheter were needed to isolate one right inferior pulmonary vein and one left superior pulmonary vein in two different patients. At the end of the procedure, all (100%) PVs were isolated. After a 2-month blanking period, 16 patients (89%) were free of symptomatic AF recurrence at a mean follow-up of 14 ± 9 months and without antiarrhythmic drugs (AADs). CONCLUSION: Cryoballoon ablation in patients with lone paroxysmal AF yields a high acute efficacy rate with a great chance of being free of symptomatic AF recurrence without antiarrhythmic drugs on a mid-term follow-up period, when offered as a first-line treatment.


Assuntos
Angioplastia com Balão/métodos , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Feminino , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
20.
Europace ; 13(6): 829-38, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21486916

RESUMO

AIMS: Functional mitral regurgitation (MR) could be managed by both cardiac resynchronization therapy (CRT) and mitral-valve surgery. Clinical decision making regarding the appropriateness of mitral-valve surgery vs. CRT is a challenging task. This study assessed the prevalence and prognosis of various degrees of functional MR in CRT candidates. Additionally, we sought to identify functional MR patients who either can be adequately managed by CRT only or will need surgery. METHODS AND RESULTS: Cardiac resynchronization therapy recipients (n= 794) were followed-up for 26 ± 18 months. Mitral regurgitation severity was quantified on scale 0-4. Cardiac resynchronization therapy responders were identified based on improvement in the New York Heart Association class and left-ventricular ejection fraction. Severity of MR and LV reverse remodelling were assessed at 3 and 12 months. Predictors of long-term MR change and CRT response were explored with multivariable models. Mitral regurgitation was present in 86%, with 35% prevalence of advanced MR (grade 3-4). Improvement of MR ≥ 1° after 12 months occurred in 46% of patients. It was relatively more frequent in patients with advanced MR at baseline (63%, P< 0.01). Baseline MR severity and change in MR at 3-month follow-up predicted response to CRT. Patients with ≥ 1° MR improvement at 12 months had more reverse remodelling compared with those with no change or worsening of MR. CONCLUSIONS: Mitral regurgitation improvement at 3 months predicts CRT response and MR improvement at 12-month follow-up. This finding could have implications for subsequent MR surgical therapies.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência da Valva Mitral/terapia , Índice de Gravidade de Doença , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/epidemiologia , Análise Multivariada , Prevalência , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA