Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38837348

RESUMO

OBJECTIVES: To assess the accuracy of a deep learning-based algorithm for fully automated detection of thoracic aortic calcifications in chest computed tomography (CT) with a focus on the aortic clamping zone. METHODS: We retrospectively included 100 chest CT scans from 91 patients who were examined on second- or third-generation dual-source scanners. Subsamples comprised 47 scans with an electrocardiogram-gated aortic angiography and 53 unenhanced scans. A deep learning model performed aortic landmark detection and aorta segmentation to derive 8 vessel segments. Associated calcifications were detected and their volumes measured using a mean-based density thresholding. Algorithm parameters (calcium cluster size threshold, aortic mask dilatation) were varied to determine optimal performance for the upper ascending aorta that encompasses the aortic clamping zone. A binary visual rating served as a reference. Standard estimates of diagnostic accuracy and inter-rater agreement using Cohen's Kappa were calculated. RESULTS: Thoracic aortic calcifications were observed in 74% of patients with a prevalence of 27-70% by aorta segment. Using different parameter combinations, the algorithm provided binary ratings for all scans and segments. The best performing parameter combination for the presence of calcifications in the aortic clamping zone yielded a sensitivity of 93% and a specificity of 82%, with an area under the receiver operating characteristic curve of 0.874. Using these parameters, the inter-rater agreement ranged from κ 0.66 to 0.92 per segment. CONCLUSIONS: Fully automated segmental detection of thoracic aortic calcifications in chest CT performs with high accuracy. This includes the critical preoperative assessment of the aortic clamping zone.


Assuntos
Aorta Torácica , Doenças da Aorta , Aprendizado Profundo , Tomografia Computadorizada por Raios X , Calcificação Vascular , Humanos , Aorta Torácica/diagnóstico por imagem , Estudos Retrospectivos , Feminino , Masculino , Calcificação Vascular/diagnóstico por imagem , Idoso , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Doenças da Aorta/diagnóstico por imagem , Algoritmos , Idoso de 80 Anos ou mais
2.
Int J Cardiovasc Imaging ; 40(4): 811-820, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38360986

RESUMO

To compare the diagnostic value of ultrahigh-resolution CT-angiography (UHR-CTA) compared with high-pitch spiral CTA (HPS-CTA) using a first-generation, dual-source photon-counting CT (PCD-CT) scanner for preprocedural planning of transcatheter aortic valve replacement (TAVR). Clinically referred patients with severe aortic valve stenosis underwent both, retrospective ECG-gated cardiac UHR-CTA (collimation: 120 × 0.2 mm) and prospective ECG-triggered aortoiliac HPS-CTA (collimation: 144 × 0.4 mm, full spectral capabilities) for TAVR planning from August 2022 to March 2023. Radiation dose was extracted from the CT reports, and the effective dose was calculated. Two radiologists analyzed UHR-CTA and HPS-CTA datasets, assessing the image quality of the aortic annulus, with regard to the lumen visibility and margin delineation using a 4-point visual-grading scale (ranges: 4 = "excellent" to 1 = "poor"). Aortic annulus area (AAA) measurements were taken for valve prosthesis sizing, with retrospective UHR-CTA serving as reference standard. A total of 64 patients were included (mean age, 81 years ± 7 SD; 28 women) in this retrospective study. HPS-CTA showed a lower radiation dose, 4.1 mSv vs. 12.6 mSv (p < 0.001). UHR-CTA demonstrated higher image quality to HPS-CTA (median score, 4 [IQR, 3-4] vs. 3 [IQR, 2-3]; p < 0.001). Quantitative assessments of AAA from both CTA datasets were strongly positively correlated (mean 477.4 ± 91.1 mm2 on UHR-CTA and mean 476.5 ± 90.4 mm2 on HPS-CTA, Pearson r2 = 0.857, p < 0.001) with a mean error of 22.3 ± 24.6 mm2 and resulted in identical valve prosthesis sizing in the majority of patients (91%). Patients with lower image quality on HPS-CTA (score value 1 or 2, n = 28) were more likely to receive different sizing recommendations (82%). Both UHR-CTA and HPS-CTA acquisitions using photon-counting CT technology provided reliable aortic annular assessments for TAVR planning. While UHR-CTA offers superior image quality, HPS-CTA is associated with lower radiation exposure. However, severely impaired image quality on HPS-CTA may impact on prosthesis sizing, suggesting that immediate post-scan image evaluations may require complementary UHR-CTA scanning.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Técnicas de Imagem de Sincronização Cardíaca , Angiografia por Tomografia Computadorizada , Eletrocardiografia , Próteses Valvulares Cardíacas , Valor Preditivo dos Testes , Desenho de Prótese , Doses de Radiação , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Feminino , Masculino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Idoso , Substituição da Valva Aórtica Transcateter/instrumentação , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Exposição à Radiação , Tomada de Decisão Clínica , Fótons , Tomografia Computadorizada Multidetectores
3.
Rofo ; 196(1): 25-35, 2024 Jan.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37793417

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS: · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT: · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Criança , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Tórax , Imagens de Fantasmas , Pulmão
4.
Diagnostics (Basel) ; 13(12)2023 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-37370957

RESUMO

BACKGROUND: This study investigates whether the scan length adjustment of prospectively ECG-triggered coronary CT angiography (CCTA) using calcium-scoring CT (CAS-CT) images can reduce overall radiation doses. METHODS: A retrospective analysis was conducted on 182 patients who underwent CAS-CT and prospectively ECG-triggered CCTA using a second-generation Dual-Source CT scanner. CCTA planning was based on CAS-CT images, for which simulated scout view planning was performed for comparison. Effective doses were compared between two scenarios: Scenario 1-CAS-CT-derived CCTA + CAS-CT and Scenario 2-scout-view-derived CCTA without CAS-CT. Dose differences were further analyzed with respect to scan mode and body mass index. RESULTS: Planning CCTA using CAS-CT led to a shorter scan length than planning via scout view (114.3 ± 9.7 mm vs. 133.7 ± 13.2 mm, p < 0.001). The whole-examination effective dose was slightly lower for Scenario 1 (3.2 [1.8-5.3] mSv vs. 3.4 [1.5-5.9] mSv; p < 0.001, n = 182). Notably, Scenario 1 resulted in a significantly lower radiation dose for sequential scans and obese patients. Only high-pitch spiral CCTA showed dose reduction in Scenario 2. CONCLUSIONS: Using CAS-CT for planning prospectively ECG-triggered CCTA reduced the overall radiation dose administered compared to scout view planning without CAS-CT, except for high-pitch spiral CCTA, where a slightly opposite effect was observed.

5.
Thorac Cardiovasc Surg Rep ; 12(1): e7-e9, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36851994

RESUMO

Coronary artery fistula (CAF), complicated by the aneurysmal formation of the coronary sinus (CS), is a very rare form of CAF. Here we report a case of a 60- year-old woman with a giant aneurysm of the CS resulting from the right coronary artery (RCA) fistula. The patient was highly symptomatic with dyspnea due to compression of cardiac chambers. CS reconstruction was performed using a pericardial patch after directly closing the fistula from the RCA to the CS.

6.
J Thorac Cardiovasc Surg ; 165(3): 958-965.e4, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34001355

RESUMO

OBJECTIVE: To evaluate the long-term incidence and outcome of aortic interventions for medically managed uncomplicated thoracic aortic dissections. METHODS: Between January 2012 and December 2018, 91 patients were discharged home with an uncomplicated, medically treated aortic dissection (involving the descending aorta with or without aortic arch involvement, no ascending involvement). After a median period of 4 (first quartile: 2, third quartile: 11) months, 30 patients (33%) required an aortic intervention. Patient characteristics, radiographic, treatment, and follow-up data were compared for patients with and without aortic interventions. A competing risk regression model was analyzed to identify independent predictors of aortic intervention and to predict the risk for intervention. RESULTS: Patients who underwent aortic interventions had significantly larger thoracic (P = .041) and abdominal (P = .015) aortic diameters, the dissection was significantly longer (P = .035), there were more communications between both lumina (P = .040), and the first communication was significantly closer to the left subclavian artery (P = .049). A descending thoracic aortic diameter exceeding 45 mm was predictive for an aortic intervention (P = .001; subdistribution hazard ratio: 3.51). The risk for aortic intervention was 27% ± 10% and 36% ± 11% after 1 and 3 years, respectively. Fourteen patients (47%) underwent thoracic endovascular aortic repair, 11 patients (37%) thoracic endovascular aortic repair and left carotid to subclavian bypass, 3 patients (10%) total arch replacement with the frozen elephant trunk technique, and 2 patients (7%) thoracoabdominal aortic replacement. We observed no in-hospital mortality. CONCLUSIONS: The need for secondary aortic interventions in patients with initially medically managed, uncomplicated descending aortic dissections is substantial. The full spectrum of aortic treatment options (endovascular, hybrid, conventional open surgical) is required in these patients.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Dissecção da Aorta Torácica , Procedimentos Endovasculares , Humanos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Procedimentos Endovasculares/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Stents
7.
Eur J Radiol ; 133: 109366, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33166834

RESUMO

OBJECTIVES: To evaluate a systolic ECG-gated high-pitch aortoiliac computed tomography (CT) angiography for planning transcatheter aortic valve implantation (TAVI). METHODS: Patients referred for TAVI underwent a combined CT imaging with retrospective, multiphasic ECG-gating of the heart and systolic ECG-gated high-pitch aortoiliac CT angiography. Consecutive patients were retrospectively included in this study group. Heart rate (HR) and heart rate variability (HRV) were assessed during the high-pitch ECG prediction phase. Aortic annulus area (AAA) was planimetrically quantified on both datasets. While only one moment of cardiac cycle was available for measurements in the high-pitch CT, the point of time in the multiphasic CT was chosen, where AAA yielded maximum size. Hypothetical prosthesis sizing was compared between multiphasic vs. high-pitch CT. RESULTS: Among 61 patients (44.2 % men, mean age: 83.3 ± 5.5 years) average heart rate and HRV were 71.0 ± 13.4 bpm and 7.3 ± 8.5 bpm. 20 patients (32.7 %) had atrial fibrillation at the time of image acquisition. There was a strong correlation of AAA as derived from multiphasic vs. the high-pitch CT (r = 0.98). The difference in AAA was 10.5 ± 17.1mm2 (455.1 ± 83.0 mm2 for multiphasic vs. 444.5 ± 87.2 mm2 for high-pitch CT) and did not reach statistical significance (p = 0.08). Hypothetical prosthesis sizing showed an agreement in 55 of 61 patients (90.2 %). A sizing based on the high-pitch CT resulted in smaller prosthesis choice in 6 patients, all of them suffering from atrial fibrillation. Mean effective radiation dose was 10.9 ± 6.1 mSv for cardiac CTA and 4.1 ± 1.0 mSv for high-pitch CTA. CONCLUSION: For patients with sinus rhythm, systolic high-pitch aortoiliac CTA provides adequate prosthesis size selection as compared with multiphasic ECG-gated cardiac CTA and may result in significantly reduced radiation exposition.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
8.
PLoS One ; 14(3): e0213339, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30835766

RESUMO

PURPOSE: To compare the diagnostic performance and raters´confidence of radiography, radiography equivalent dose multi-detector computed tomography (RED-MDCT) and radiography equivalent dose cone beam computed tomography (RED-CBCT) for finger fractures. METHODS: Fractures were inflicted artificially and randomly to 10 cadaveric hands of body donors. Radiography as well as RED-MDCT and RED-CBCT imaging were performed at dose settings equivalent to radiography. Images were de-identified and analyzed by three radiologists regarding finger fractures, joint involvement and confidence with their findings. Reference standard was consensus reading by two radiologists of the fracturing protocol and high-dose multi-detector computed tomography (MDCT) images. Sensitivity and specificity were calculated and compared with Cochrane´s Q and post hoc analysis. Rater´s confidence was calculated with Friedman Test and post hoc Nemenyi Test. RESULTS: Rater´s confidence, inter-rater correlation, specificity for fractures and joint involvement were higher in RED-MDCT and RED-CBCT compared to radiography. No differences between the modalities were found regarding sensitivity. CONCLUSION: In this phantom study, radiography equivalent dose computed tomography (RED-CT) demonstrates a partly higher diagnostic accuracy than radiography. Implementing RED-CT in the diagnostic work-up of finger fractures could improve diagnostics, support correct classification and adequate treatment. Clinical studies should be performed to confirm these preliminary results.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Traumatismos dos Dedos/diagnóstico , Fraturas Ósseas/diagnóstico , Tomografia Computadorizada Multidetectores/métodos , Imagens de Fantasmas , Radiografia/métodos , Traumatismos dos Dedos/diagnóstico por imagem , Fraturas Ósseas/diagnóstico por imagem , Humanos , Doses de Radiação
9.
Biomed Res Int ; 2016: 2384894, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27990424

RESUMO

Objective. In this study, we compared prostate cancer detection rates between MRI-TRUS fusion targeted and systematic biopsies using a robot-guided, software based transperineal approach. Methods and Patients. 52 patients received a MRIT/TRUS fusion followed by a systematic volume adapted biopsy using the same robot-guided transperineal approach. The primary outcome was the detection rate of clinically significant disease (Gleason grade ≥ 4). Secondary outcomes were detection rate of all cancers, sampling efficiency and utility, and serious adverse event rate. Patients received no antibiotic prophylaxis. Results. From 52 patients, 519 targeted biopsies from 135 lesions and 1561 random biopsies were generated (total n = 2080). Overall detection rate of clinically significant PCa was 44.2% (23/52) and 50.0% (26/52) for target and random biopsy, respectively. Sampling efficiency as the median number of cores needed to detect clinically significant prostate cancer was 9 for target (IQR: 6-14.0) and 32 (IQR: 24-32) for random biopsy. The utility as the number of additionally detected clinically significant PCa cases by either strategy was 0% (0/52) for target and 3.9% (2/52) for random biopsy. Conclusions. MRI/TRUS fusion based target biopsy did not show an advantage in the overall detection rate of clinically significant prostate cancer.


Assuntos
Biópsia Guiada por Imagem/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Idoso , Antibacterianos/química , Reações Falso-Positivas , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/cirurgia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Robótica , Software
10.
Eur J Nucl Med Mol Imaging ; 43(5): 889-897, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26592938

RESUMO

PURPOSE: Multiparametric magnetic resonance imaging (mpMRI) is widely used in radiation treatment planning of primary prostate cancer (PCA). Focal dose escalation to the dominant intraprostatic lesions (DIPL) may lead to improved PCA control. Prostate-specific membrane antigen (PSMA) is overexpressed in most PCAs. (68)Ga-labelled PSMA inhibitors have demonstrated promising results in detection of PCA with PET/CT. The aim of this study was to compare (68)Ga-PSMA PET/CT with MRI for gross tumour volume (GTV) definition in primary PCA. METHODS: This retrospective study included 22 patients with primary PCA analysed after (68)Ga-PSMA PET/CT and mpMRI. GTVs were delineated on MR images by two radiologists (GTV-MRIrad) and two radiation oncologists separately. Both volumes were merged leading to GTV-MRIint. GTVs based on PET/CT were delineated by two nuclear medicine physicians in consensus (GTV-PET). Laterality (left, right, and left and right prostate lobes) on mpMRI, PET/CT and pathological analysis after biopsy were assessed. RESULTS: Mean GTV-MRIrad, GTV-MRIint and GTV-PET were 5.92, 3.83 and 11.41 cm(3), respectively. GTV-PET was significant larger then GTV-MRIint (p = 0.003). The MRI GTVs GTV-MRIrad and GTV-MRIint showed, respectively, 40 % and 57 % overlap with GTV-PET. GTV-MRIrad and GTV-MRIint included the SUVmax of GTV-PET in 12 and 11 patients (54.6 % and 50 %), respectively. In nine patients (47 %), laterality on mpMRI, PET/CT and histopathology after biopsy was similar. CONCLUSION: Ga-PSMA PET/CT and mpMRI provided concordant results for delineation of the DIPL in 47 % of patients (40 % - 54 % of lesions). GTV-PET was significantly larger than GTV-MRIint. (68)Ga-PSMA PET/CT may have a role in radiation treatment planning for focal radiation to the DIPL. Exact correlation of PET and MRI images with histopathology is needed.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador , Idoso , Idoso de 80 Anos ou mais , Ácido Edético/análogos & derivados , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Masculino , Pessoa de Meia-Idade , Oligopeptídeos , Compostos Organometálicos , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Compostos Radiofarmacêuticos , Dosagem Radioterapêutica , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA