Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
2.
Braz J Cardiovasc Surg ; 37(4): 430-438, 2022 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-35976202

RESUMO

OBJECTIVE: To compare health-related quality of life (HRQoL) of patients primarily treated with a no-touch saphenous vein graft with that of patients who received a conventional graft. METHODS: The study included all individuals treated with a percutaneous coronary intervention (PCI) on a saphenous vein graft (SVG) between January 2006 and June 2020. The RAND-36 health survey was used to assess HRQoL. The Mann-Whitney U test was used to test differences in HRQoL between the two groups. Effect size was estimated via Cohen's d. The average treatment effect between the groups was tested by propensity score matching (PSM). RESULTS: Of the 346 patients treated with a PCI in a stenosed or occluded SVG, 165 responded to RAND-36 (no-touch: n=48; conventional: n=117). Patients with a no-touch graft reported better mean values on seven of the eight health survey domains. Statistically significant differences were observed for four of the domains, all in favour of the no-touch group. The effect size estimates indicated a small difference for five domains, with the highest values (>0.40) seen for the general health and energy/fatigue domains. PSM confirmed a statistically significant difference for the physical functioning and general health domains. CONCLUSION: At a mean follow-up of 5.4 years, patients who received a PCI in no-touch vein grafts showed significantly better HRQoL than those who received a PCI in conventional vein grafts.


Assuntos
Intervenção Coronária Percutânea , Ponte de Artéria Coronária/efeitos adversos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Qualidade de Vida , Veia Safena/transplante , Resultado do Tratamento
3.
Rev. bras. cir. cardiovasc ; 37(4): 430-438, Jul.-Aug. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1394740

RESUMO

ABSTRACT Objective: To compare health-related quality of life (HRQoL) of patients primarily treated with a no-touch saphenous vein graft with that of patients who received a conventional graft. Methods: The study included all individuals treated with a percutaneous coronary intervention (PCI) on a saphenous vein graft (SVG) between January 2006 and June 2020. The RAND-36 health survey was used to assess HRQoL. The Mann-Whitney U test was used to test differences in HRQoL between the two groups. Effect size was estimated via Cohen's d. The average treatment effect between the groups was tested by propensity score matching (PSM). Results: Of the 346 patients treated with a PCI in a stenosed or occluded SVG, 165 responded to RAND-36 (no-touch: n=48; conventional: n=117). Patients with a no-touch graft reported better mean values on seven of the eight health survey domains. Statistically significant differences were observed for four of the domains, all in favour of the no-touch group. The effect size estimates indicated a small difference for five domains, with the highest values (>0.40) seen for the general health and energy/fatigue domains. PSM confirmed a statistically significant difference for the physical functioning and general health domains. Conclusion: At a mean follow-up of 5.4 years, patients who received a PCI in no-touch vein grafts showed significantly better HRQoL than those who received a PCI in conventional vein grafts.

5.
Braz J Cardiovasc Surg ; 37(1): 135-138, 2022 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-35274524

RESUMO

The modality of repeat revascularization due to late graft failure is a debated topic. The latest available European guidelines recommend redo coronary artery bypass graft (CABG) for cases of extensively diseased and/or occluded grafts and those with diffuse native vessel disease. We present the case of a patient being relieved of recurrent unstable angina pectoris with redo CABG using no-touch saphenous vein grafts after repeated and unsuccessful attempts with percutaneous coronary intervention (PCI). This could be an alternative to PCI in patients with a complex medical history. Teamwork between cardiologists and surgeons is pivotal in deciding the best treatment modality.


Assuntos
Intervenção Coronária Percutânea , Ponte de Artéria Coronária , Humanos , Veia Safena/transplante , Resultado do Tratamento
6.
Rev. bras. cir. cardiovasc ; 37(1): 135-138, Jan.-Feb. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1365541

RESUMO

Abstract The modality of repeat revascularization due to late graft failure is a debated topic. The latest available European guidelines recommend redo coronary artery bypass graft (CABG) for cases of extensively diseased and/or occluded grafts and those with diffuse native vessel disease. We present the case of a patient being relieved of recurrent unstable angina pectoris with redo CABG using no-touch saphenous vein grafts after repeated and unsuccessful attempts with percutaneous coronary intervention (PCI). This could be an alternative to PCI in patients with a complex medical history. Teamwork between cardiologists and surgeons is pivotal in deciding the best treatment modality.

11.
J Card Surg ; 36(10): 3702-3708, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34312919

RESUMO

BACKGROUND: Randomized trials show high long-term patency for no-touch saphenous vein grafts in coronary artery bypass grafting. The patency rate in off-pump coronary bypass surgery for these grafts has not been investigated. Our center participated in the CORONARY randomized trial, NCT00463294. This is a study aimed to assess the patency of no-touch saphenous veins in on- versus off-pump coronary bypass surgery at five-year follow-up. METHODS: Fifty-six patients were included. Forty of 49 patients, alive at 5 years, participated in this follow-up. There were 21 and 19 patients in the on- and off-pump groups respectively. No-touch saphenous veins were used to bypass all targets and in some cases the left anterior descending artery. Graft patency according to distal anastomosis was evaluated with computed tomography angiography. RESULTS: The five-year patency rate was 123/139 (88.5%). The patency for the no-touch vein grafts was 57/64 (89.1%) in the on-pump versus 37/45 (82.2%) in the off-pump group. All left internal thoracic arteries except for one, 29/30 (96.6%), were patent. All vein grafts used to bypass the left anterior descending and the diagonal arteries were patent 32/32. The lowest patency rate for the saphenous veins was to the right coronary territory, particularly in off-pump surgery (80.0% vs. 62.5% for the on- respective off-pump groups). CONCLUSIONS: Comparable 5-year patency for the no-touch saphenous veins and the left internal thoracic arteries to the left anterior descending territory in both on- and off-pump coronary artery bypass grafting. Graft patency in off-pump CABG is lower to the right coronary artery.


Assuntos
Artéria Torácica Interna , Angiografia Coronária , Ponte de Artéria Coronária , Humanos , Veia Safena/diagnóstico por imagem , Resultado do Tratamento , Grau de Desobstrução Vascular
13.
Scand Cardiovasc J ; 55(4): 245-253, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33733984

RESUMO

To investigate the results of percutaneous coronary intervention (PCI) in saphenous vein grafts after coronary artery bypass grafting (CABG). Design. MEDLINE, Embase, and the Cochrane library were searched for relevant articles published between 1 January 2000 and 29 February 2020. The PICO (population, intervention, comparison, outcome) model was applied in constructing the clinical question. Two independent researchers performed the literature search. Thirty-six articles were identified and subjected to a quality assessment. The primary outcomes of the meta-analysis were long-term in-stent restenosis and long-term major adverse cardiac events (MACE). Results. In-stent restenosis was 9.4% (95% CI: 4.2-14.7%) and MACE was 35.3% (95% CI: 27-43.7%) at mean time 2.7 ± 1.0 years. The secondary outcomes were the unsuccessful PCI rate (7.7%; 95% CI: 2.9-12.5%), 30-day MACE (4.3%; 95% CI: 2.5-6.1%), and 1-year MACE (15.5%; 95% CI: 11.7-19.3%). The use of drug-eluting stents resulted in better outcomes at least in term of in-stent restenosis, while the benefit of using embolic protection devices was questionable. Conclusions. PCI of a stenosed or occluded saphenous vein graft is a challenge for interventional cardiologists, and is still associated with relatively high rates of restenosis, MACE, and procedural failure. All efforts to enhance the results are warranted, including improved quality of the venous grafts used during CABG.


Assuntos
Ponte de Artéria Coronária , Intervenção Coronária Percutânea , Veia Safena , Reestenose Coronária/etiologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Veia Safena/cirurgia
14.
Asian Cardiovasc Thorac Ann ; 29(6): 490-497, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33334128

RESUMO

OBJECTIVE: Concerns have been raised regarding whether skeletonization of the internal thoracic artery could damage the graft and thereby reduces its patency. The objective of this study was to compare patency rates at mid- and long-term follow-up between pedicled and skeletonized left internal thoracic artery grafts. METHODS: This randomized controlled trial included 109 patients undergoing coronary artery bypass surgery. The patients were assigned to receive either one pedicled or one skeletonized left internal thoracic artery graft to the left anterior descending artery. Follow-up was performed at 3 years with conventional angiography, and at 8 years with computed tomography angiography. Differences between patency rates were analyzed with Fisher's exact test and a generalized linear model. RESULTS: The patency rates for pedicled and skeletonized left internal thoracic artery grafts were 46/48 (95.8%) versus 47/52 (90.4%), p = 0.44 at 3 years, and 40/43 (93.0%) versus 37/41 (90.2%), p = 0.71 at 8 years, respectively. The difference in patency rates for pedicled and skeletonized grafts was 5.4% (95% confidence interval: -4.2-14.5) at 3 years and 2.8% (95% confidence interval: -9.9-14.1) at 8 years. All failed grafts, except for one with a localized stenosis, were anastomosed to native coronary arteries with a stenosis less than 70%. Three patients suffered sternal wound infections (two in the pedicled group, one in the skeletonized group). CONCLUSIONS: The skeletonization technique can be used without jeopardizing the patency of the left internal thoracic artery. The most important factor in graft failure was target artery stenosis below 70%.


Assuntos
Artéria Torácica Interna , Constrição Patológica , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Humanos , Artéria Torácica Interna/diagnóstico por imagem , Artéria Torácica Interna/cirurgia , Esterno , Resultado do Tratamento , Grau de Desobstrução Vascular
15.
J Thorac Cardiovasc Surg ; 161(2): 624-630, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-31831193

RESUMO

BACKGROUND: In 2004, a prospective randomized trial demonstrated that after 3 years, saphenous veins (SVs) harvested with a no touch (NT) technique had a greater patency than radial grafts for coronary bypass surgery. Here we report the 8-year follow-up data of this trial. METHODS: The trial included 108 patients undergoing coronary artery bypass grafting (CABG). Each patient was assigned to receive 1 NT SV and 1 radial artery (RA) graft to either the left or right coronary territory to complement the left internal thoracic artery (LITA). Sequential grafting was common, so overall graft patency as well as the patency of each anastomosis were assessed. RESULTS: Angiography was performed in 84 patients (78%) at mean of 97 months postoperatively. Graft patency were high and similar for both NT and RA: 86% for NT versus 79% for RA (P = .22). The patency of coronary anastomoses was significantly higher with the NT SV grafts (91% vs 81%; P = .046). The NT grafts also had excellent patency in coronary arteries with <90% stenosis (93% patency) and in coronary arteries of small diameter (87% patency) or with mild calcification (88% patency). Patency for the LITA was 92%. CONCLUSIONS: NT SV grafts have excellent patency similar to that of RA grafts after 8 years. In addition, NT SV grafts can be used in situations that are not ideal for RA grafts.


Assuntos
Ponte de Artéria Coronária/métodos , Artéria Radial/transplante , Veia Safena/transplante , Adulto , Idoso , Angiografia por Tomografia Computadorizada , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial/diagnóstico por imagem , Veia Safena/diagnóstico por imagem , Enxerto Vascular/métodos , Grau de Desobstrução Vascular
16.
Asian Cardiovasc Thorac Ann ; 29(5): 457-467, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33307718

RESUMO

The saphenous vein is the most commonly used conduit for coronary artery bypass grafting. Arterial grafts are harvested with the outer pedicle intact whereas saphenous veins are harvested with the pedicle removed in the conventional graft harvesting technique. This conventional procedure causes considerable vascular damage. One strategy to improve vein graft patency has been to provide external support. Ongoing studies show that fitting a metal external support improves conventionally harvested saphenous vein graft patency. On the other hand, the no-touch technique of harvesting the saphenous vein provides an improved graft with long-term patency comparable to that of the internal mammary artery. This improvement is suggested to be due to preservation of vessel structures. Interestingly, many of the mechanisms proposed to be associated with the beneficial actions of an artificial external support on saphenous vein graft patency are similar to those underlying the beneficial effect of no-touch saphenous vein grafts where the intact outer layer acts as a natural support. Additional actions of external supports have been advocated, including promotion of angiogenesis, increased production of vascular-protective factors, and protection of endothelial cells. Using no-touch harvesting, normal vascular architecture is maintained, tissue and cell damage is minimized, and factors beneficial for graft patency are preserved. In this review, the significance of external support of saphenous vein grafts in coronary artery bypass grafting is discussed.


Assuntos
Artéria Torácica Interna , Veia Safena , Ponte de Artéria Coronária/efeitos adversos , Células Endoteliais , Humanos , Grau de Desobstrução Vascular
17.
Braz J Cardiovasc Surg ; 35(1): 91-99, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32270965

RESUMO

The saphenous vein is the most common conduit used in coronary artery bypass grafting (CABG) yet its failure rate is higher compared to arterial grafts. An improvement in saphenous vein graft performance is therefore a major priority in CABG. No-touch harvesting of the saphenous vein is one of the few interventions that has shown improved patency rates, comparable to that of the left internal thoracic artery. After more than two decades of no-touch research, this technique is now recognized as a Class IIa recommendation in the 2018 European Society of Cardiology and the European Association for Cardio-Thoracic Surgery guidelines on myocardial revascularization. In this review, we describe the structural alterations that occur in conventional versus no-touch saphenous vein grafts and how these changes affect graft patency. In addition, we discuss various strategies aimed at repairing saphenous vein grafts prepared at conventional CABG.


Assuntos
Artéria Torácica Interna , Veia Safena , Ponte de Artéria Coronária , Humanos , Resultado do Tratamento , Grau de Desobstrução Vascular
18.
Am Heart J ; 224: 17-24, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32272256

RESUMO

The SWEDEGRAFT study (ClinicalTrials.gov Identifier: NCT03501303) tests the hypothesis that saphenous vein grafts (SVGs) harvested with the "no-touch" technique improves patency of coronary artery bypass grafts compared with the conventional open skeletonized technique. This article describes the rationale and design of the randomized trial and baseline characteristics of the population enrolled during the first 9 months of enrollment. The SWEDEGRAFT study is a prospective, binational multicenter, open-label, registry-based trial in patients undergoing first isolated nonemergent coronary artery bypass grafting (CABG), randomized 1:1 to no-touch or conventional open skeletonized vein harvesting technique, with a planned enrollment of 900 patients. The primary end point is the proportion of patients with graft failure defined as SVGs occluded or stenosed >50% on coronary computed tomography angiography at 2 years after CABG, earlier clinically driven coronary angiography demonstrating an occluded or stenosed >50% vein graft, or death within 2 years. High-quality health registries and coronary computed tomography angiography are used to assess the primary end point. The secondary end points include wound healing in the vein graft sites and the composite outcome of major adverse cardiac events during the first 2 years based on registry data. Demographics of the first 200 patients enrolled in the trial and other CABG patients operated in Sweden during the same time period are comparable when the exclusion criteria are taken into consideration. RCT# NCT03501303.


Assuntos
Doença da Artéria Coronariana/cirurgia , Oclusão de Enxerto Vascular/prevenção & controle , Sistema de Registros , Veia Safena/transplante , Coleta de Tecidos e Órgãos/métodos , Idoso , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
20.
Rev. bras. cir. cardiovasc ; 35(1): 91-99, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1092466

RESUMO

Abstract The saphenous vein is the most common conduit used in coronary artery bypass grafting (CABG) yet its failure rate is higher compared to arterial grafts. An improvement in saphenous vein graft performance is therefore a major priority in CABG. No-touch harvesting of the saphenous vein is one of the few interventions that has shown improved patency rates, comparable to that of the left internal thoracic artery. After more than two decades of no-touch research, this technique is now recognized as a Class IIa recommendation in the 2018 European Society of Cardiology and the European Association for Cardio-Thoracic Surgery guidelines on myocardial revascularization. In this review, we describe the structural alterations that occur in conventional versus no-touch saphenous vein grafts and how these changes affect graft patency. In addition, we discuss various strategies aimed at repairing saphenous vein grafts prepared at conventional CABG.


Assuntos
Humanos , Veia Safena , Artéria Torácica Interna , Grau de Desobstrução Vascular , Ponte de Artéria Coronária , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA