Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
JACC Case Rep ; 26: 102060, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38094170

RESUMO

We report the case of a 64-year-old man with a history of chemotherapy-induced cardiomyopathy requiring heart transplant in 2022 who underwent successful endomyocardial biopsy using patient-specific computed tomographic fluoroscopic projections. (Level of Difficulty: Beginner.).

2.
CJC Open ; 5(1): 24-34, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36700182

RESUMO

Background: This study sought to compare characteristics and outcomes of patients who underwent surgical aortic valve replacement (SAVR) after being referred to a heart team (HT), to those of patients referred directly for SAVR. Methods: An analysis of patients who underwent SAVR from 2015 to 2020 was conducted. Patients were categorized into 3 groups, as follows: (i) H-HT: patients referred to the HT from 2015 to 2017 (historical cohort); (ii) C-HT: patients referred to the HT from 2018 to 2020 (contemporary cohort); and (iii) No-HT: patients referred directly to cardiac surgery from 2018 to 2020. Two subanalyses were performed: H-HT vs C-HT patients, and C-HT vs No-HT patients. The primary outcome was a composite of in-hospital mortality, prolonged intubation, reoperation, sternal wound infection, and stroke. Results: This study consisted of 288 patients, distributed as follows: H-HT (n = 45); C-HT (n = 51); and No-HT (n = 192). The mean ages of H-HT, C-HT, and No-HT patients was 76.3 ± 6.9 years, 73.3 ± 7.6 years, and 69.6 ± 9.7 years, respectively (P = 0.0001). H-HT, C-HT, and No-HT patients had average Society of Thoracic Surgeons scores of 4.8 ± 2.2, 3.2 ± 1.6, and 4.2 ± 2 (P = 0.002), respectively. The composite outcome rate was more than 5 times higher among H-HT patients compared to that among the C-HT patients (20.0 vs 3.9%, P = 0.02), and was numerically higher in No-HT compared to C-HT patients (13.0 vs 3.9%, P = 0.07). Conclusions: Referral to an HT appears to be primarily driven by higher chronological age rather than overall risk profile. Patients assessed by the HT prior to undergoing SAVR have a low incidence of complications, comparable to that among patients referred directly to cardiac surgery.


Contexte: Cette étude visait à comparer les caractéristiques et le devenir de patients ayant subi une chirurgie de remplacement valvulaire aortique après avoir été orientés vers une équipe de cardiologie (EC) à ceux de patients orientés directement en chirurgie cardiaque pour une chirurgie de remplacement valvulaire aortique. Méthodologie: Une analyse portant sur les patients ayant subi une chirurgie de remplacement valvulaire aortique de 2015 à 2020 a été effectuée. Les patients ont été divisés en trois groupes, à savoir : i) CH-POEC : patients orientés vers une EC de 2015 à 2017 (cohorte historique); ii) CC-POEC : patients orientés vers une EC de 2018 à 2020 (cohorte contemporaine); iii) PODC : patients orientés directement en chirurgie cardiaque de 2018 à 2020. Deux sous-analyses ont été effectuées : CH-POEC vs CC-POEC, et CC-POEC vs PODC. Le paramètre d'évaluation principal était composite. Il comprenait la mortalité hospitalière, l'intubation prolongée, la réopération, l'infection de la plaie sternale et l'accident vasculaire cérébral. Résultats: L'étude regroupait 288 patients, répartis comme suit : CH-POEC, n = 45; CC-POEC, n = 51; PODC, n = 192. L'âge moyen dans les groupes CH-POEC, CC-POEC et PODC était respectivement de 76,3 ± 6,9 ans, 73,3 ± 7,6 ans et 69,6 ± 9,7 ans (P = 0,0001). Les groupes CH-POEC, CC-POEC et PODC présentaient des indices STS (Society of Thoracic Surgeons) moyens de 4,8 ± 2,2, 3,2 ± 1,6 et 4,2 ± 2 (P = 0,002), respectivement. Le taux composite d'événements au sein du groupe CH-POEC était plus de cinq fois supérieur à celui noté dans le groupe CC-POEC (20,0 vs 3,9 %, P = 0,02). Il était aussi plus élevé au sein du groupe PODC comparativement au groupe CC-POEC (13,0 vs 3,9 %, P = 0,07). Conclusions: Le principal motif d'orientation vers une EC semble être un âge chronologique avancé plutôt que le profil de risque global. Chez les patients qui sont évalués par une EC avant de subir une chirurgie de remplacement valvulaire aortique, l'incidence de complications est faible et comparable à celle observée chez les patients orientés directement en chirurgie cardiaque.

3.
World J Cardiol ; 14(4): 250-259, 2022 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-35582469

RESUMO

BACKGROUND: Vasoplegia is a common complication of cardiac surgery but its causal relationship with preoperative use of renin angiotensin system (RAS) blockers [angiotensin converting enzyme inhibitors (ACEIs) and angiotensin receptor blockers (ARB)] is still debated. AIM: To update and summarize data on the effect of preoperative use of RAS blockers on incident vasoplegia. METHODS: All published studies from MEDLINE, EMBASE, and Web of Science providing relevant data through January 13, 2021 were identified. A random-effects meta-analysis method was used to pool estimates, and post-cardiac surgery shock was differentiated from vasoplegia. RESULTS: Ten studies reporting on a pooled population of 15672 patients (none looking at ARBs exclusively) were included in the meta-analysis. All were case-control studies. Use of ACEIs was associated with an increased risk of vasoplegia [pooled adjusted odds ratio (Aor) of 2.06, 95%CI: 1.45-2.93] and increased inotropic/vasopressor support requirement (pooled aOR 1.19, 95%CI: 1.10-1.29). Post-cardiac surgery shock was increased in the presence of left ventricular dysfunction (pooled aOR 2.32, 95%CI: 1.60-3.36; I 2 49%) but not increased by the use of beta blockers (pooled aOR 0.78, 95%CI: 0.36-1.69; I 2 77%). Two randomized control trials (RCTs), not eligible for the meta-analysis, did not show an association between continuation of RAS blockers and vasoplegia. CONCLUSION: Preoperative continuation of ACEIs is associated with an increased need for inotropic support postoperatively and with an increased risk of vasoplegia in observational studies but not in RCTs. The absence of a consensus definition of vasoplegia should lead to the use of perioperative cardiovascular monitoring when designing RCTs to better understand this discrepancy.

4.
JACC Cardiovasc Interv ; 13(15): 1733-1748, 2020 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-32763070

RESUMO

Transcatheter edge-to-edge mitral valve repair is a viable alternative to surgery in patients with severe mitral regurgitation and high surgical risk. Yet the specific group of patients who would optimally benefit from this therapy remains to be determined. Selection of patients for transcatheter strategy is currently based on surgical prognostic scores and technical feasibility. Meanwhile, various clinical, anatomic, and procedural factors have been recently recognized as predictors of adverse outcomes following transcatheter edge-to-edge mitral valve repair, including device failure, recurrent mitral regurgitation, and mortality. Integration of these prognostic factors in the decision-making process of the heart team might improve patient management and outcomes. Herein, the authors review the different factors related to symptomatic status, comorbidity, serum biomarkers, echocardiographic findings, and procedural technique that have been identified as independent predictors of adverse outcome following transcatheter edge-to-edge mitral valve repair and discuss their potential application in everyday clinical practice.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Tomada de Decisão Clínica , Ecocardiografia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/etiologia , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
5.
Can J Cardiol ; 36(12): 1977.e13-1977.e15, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32735847

RESUMO

Mitral regurgitation (MR) is a known complication of transcatheter aortic valve replacement (TAVR). We report a case of a 90-year-old man with severe symptomatic aortic stenosis who underwent elective TAVR. The procedure was complicated by severe functional MR from left ventricular stunning and dilatation caused by hypotension throughout the procedure. An Impella CP (Abiomed, Inc, Danvers, MA) was inserted to unload the left ventricle and decrease its size with subsequent improvement in MR severity, which was sustained after Impella CP removal. In conclusion, we present the first case of successful management of post-TAVR severe functional MR with an Impella CP.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Circulação Assistida , Ventrículos do Coração , Coração Auxiliar , Insuficiência da Valva Mitral , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Circulação Assistida/instrumentação , Circulação Assistida/métodos , Dilatação Patológica/diagnóstico , Dilatação Patológica/etiologia , Dilatação Patológica/terapia , Ecocardiografia Transesofagiana/métodos , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/terapia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/terapia , Índice de Gravidade de Doença , Cirurgia Assistida por Computador/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
6.
Int J Comput Assist Radiol Surg ; 15(4): 577-588, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32130646

RESUMO

PURPOSE: Transcatheter aortic valve replacement (TAVR) is the standard of care in a large population of patients with severe symptomatic aortic valve stenosis. The sizing of TAVR devices is done from ECG-gated CT angiographic image volumes. The most crucial step of the analysis is the determination of the aortic valve annular plane. In this paper, we present a fully tridimensional recursive multiresolution convolutional neural network (CNN) to infer the location and orientation of the aortic valve annular plane. METHODS: We manually labeled 1007 ECG-gated CT volumes from 94 patients with severe degenerative aortic valve stenosis. The algorithm was implemented and trained using the TensorFlow framework (Google LLC, USA). We performed K-fold cross-validation with K = 9 groups such that CT volumes from a given patient are assigned to only one group. RESULTS: We achieved an average out-of-plane localization error of (0.7 ± 0.6) mm for the training dataset and of (0.9 ± 0.8) mm for the evaluation dataset, which is on par with other published methods and clinically insignificant. The angular orientation error was (3.9 ± 2.3)° for the training dataset and (6.4 ± 4.0)° for the evaluation dataset. For the evaluation dataset, 84.6% of evaluation image volumes had a better than 10° angular error, which is similar to expert-level accuracy. When measured in the inferred annular plane, the relative measurement error was (4.73 ± 5.32)% for the annular area and (2.46 ± 2.94)% for the annular perimeter. CONCLUSIONS: The proposed algorithm is the first application of CNN to aortic valve planimetry and achieves an accuracy on par with proposed automated methods for localization and approaches an expert-level accuracy for orientation. The method relies on no heuristic specific to the aortic valve and may be generalizable to other anatomical features.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada Multidetectores/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Próteses Valvulares Cardíacas , Humanos , Aprendizado de Máquina , Masculino , Redes Neurais de Computação
7.
Catheter Cardiovasc Interv ; 93(7): 1367-1373, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30536569

RESUMO

OBJECTIVE: This study sought to assess the potential benefits of the transradial approach (TRA) as an alternative vascular access to the classical contralateral femoral approach for transcatheter aortic valve replacement (TAVR). BACKGROUND: Vascular and bleeding complications in TAVR have gradually decreased owing to operator experience and downsizing of the delivery system. However, about 1/4 of vascular access site complications are related to the transfemoral (TF) secondary access. METHODS: We compared the outcomes at 30 days according to VARC-2 after TAVR of a prospective cohort of 217 consecutive patients undergoing right or left TRA as the second vascular access (TRA-TF TAVR) and a retrospective cohort of 194 consecutive patients undergoing TF approach as a second vascular access (TF-TF TAVR). RESULTS: Baseline clinical characteristics and risk scores were well matched in both groups. Procedural success rate was 99.7%. Fluoro time was significantly lower in the TF-TF TAVR group (16.9 ± 7.2 vs. 19.1 ± 7.8 min, P = 0.003); however, there was no significant difference in x-ray exposure, procedure time or amount of contrast used. In the TRA-TF TAVR group, there were no complications related to the TRA access and there were less vascular and bleeding complications (18.0% vs. 9.7%, P = 0.014; 17.0% vs. 9.2%, P = 0.026, respectively), although blood transfusion requirement or hospitalization duration stay were similar in both groups. CONCLUSIONS: TRA approach as alternative secondary vascular access in TAVR is safe and feasible and is associated with a significant decrease in vascular and bleeding complications. Further, large-scale studies are warranted to confirm the potential benefit of this approach.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico , Artéria Femoral , Hospitais com Alto Volume de Atendimentos , Artéria Radial , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Tempo de Internação , Masculino , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Estudos Prospectivos , Punções , Artéria Radial/diagnóstico por imagem , Exposição à Radiação , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
J Cardiovasc Comput Tomogr ; 12(4): 338-343, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29735255

RESUMO

BACKGROUND: Aortic valve calcification patterns were associated with short- and long-term outcomes in previous small observational datasets of patients undergoing transcatheter aortic valve implantation (TAVI). The specific impact of multi detector-row computed tomography (MDCT) findings on outcomes in women has not been reported. We sought to describe the associations between MDCT characteristics and clinical outcomes in a registry of 547 women undergoing TAVI. METHODS: WIN-TAVI is the first all-female registry to study the safety and effectiveness of TAVI in women (n = 1019). Thirteen sites participated in the MDCT sub-study and contributed pre-TAVI MDCT studies in 547 consecutive subjects. All MDCT data were analyzed in an independent core lab blinded to clinical outcomes. Key measurements included number of valve leaflets, aortic annulus area and perimeter, left and right coronary artery height, aortic cusp calcium volume, commissural calcification and left ventricular outflow tract (LVOT) calcification. Calcium volume of the aortic valvular complex was quantified using a threshold relative to patient-specific contrast attenuation in the arterial blood pool. We examined univariate and multivariate associations between ECG-gated contrast MDCT characteristics and 1-year mortality or stroke, new pacemaker implantation and new onset atrial fibrillation (AF). RESULTS: The CT sub-study sample had a mean age of 82.8 ±â€¯6.3 years, mean logistic EuroSCORE of 17.8 ±â€¯11.3%, and mean STS score of 8.2 ±â€¯7.4%. Transfemoral access was used in 89.6% of patients. After multivariate adjustment, moderate or severe LVOT calcification was an independent predictor of 1-year mortality or stroke (HR = 1.91; 95% CI: 1.11-3.30; p = 0.02). Calcium volume in the right coronary cusp was an independent predictor of new pacemaker (HR = 1.18 per 100 m3 increment; p = 0.04), whereas calcium volume of the non-coronary cusp had a protective effect (HR = 0.78 per 100 mm3 increment; p = 0.004). Severe calcification of the non-coronary/right-coronary commissure was an independent predictor of new AF (HR = 5.1; p = 0.008). CONCLUSION: Computed tomography provides important prognostic information in women undergoing TAVI. Moderate or severe LVOT calcification is associated to an almost two-fold increased risk of mortality or stroke at one year. Different calcification patterns of the aortic valve may predict diverse rhythm abnormalities.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/transplante , Arritmias Cardíacas/epidemiologia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Tomografia Computadorizada Multidetectores , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Saúde da Mulher , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/terapia , Calcinose/mortalidade , Calcinose/fisiopatologia , Estimulação Cardíaca Artificial , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Estimativa de Kaplan-Meier , Modelos Logísticos , Análise Multivariada , América do Norte/epidemiologia , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/mortalidade , Obstrução do Fluxo Ventricular Externo/fisiopatologia
9.
Eur Heart J ; 39(8): 676-684, 2018 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-29253177

RESUMO

Aims: Life-threatening complications occur during transcatheter aortic valve implantation (TAVI) which can require emergent cardiac surgery (ECS). Risks and outcomes of patients needing ECS during or immediately after TAVI are still unclear. Methods and results: Incidence, risk factors, management, and outcomes of patients requiring ECS during transfemoral (TF)-TAVI were analysed from a contemporary real-world multicentre registry. Between 2013 and 2016, 27 760 patients underwent TF-TAVI in 79 centres. Of these, 212 (0.76%) patients required ECS (age 82.4 ± 6.3 years, 67.5% females, logistic EuroSCORE: 17.1%, STS-score 5.8%). The risk of ECS declined from 2013 (1.07%) to 2014 (0.70%) but remained stable since. Annual TF-TAVI numbers have more than doubled from 2013 to 2016. Leading causes for ECS were left ventricular perforation by the guidewire (28.3%) and annular rupture (21.2%). Immediate procedural mortality (<72 h) of TF-TAVI patients requiring ECS was 34.6%. Overall in-hospital mortality was 46.0%, and highest in case of annular rupture (62%). Independent predictors of in-hospital mortality following ECS were age > 85 years [odds ratio (OR) 1.87, 95% confidence interval (95% CI) (1.02-3.45), P = 0.044], annular rupture [OR 1.96, 95% CI (0.94-4.10), P = 0.060], and immediate ECS [OR 3.12, 95% CI (1.07-9.11), P = 0.037]. One year of survival of the 114 patients surviving the in-hospital period was only 40.4%. Conclusion: Between 2014 and 2016, the need for ECS remained stable around 0.7%. Left ventricular guidewire perforation and annular rupture were the most frequent causes, accounting for almost half of ECS cases. Half of the patients could be salvaged by ECS-nevertheless, 1 year of all-cause mortality was high even in those ECS patients surviving the in-hospital period.


Assuntos
Estenose da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Mortalidade Hospitalar/tendências , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Procedimentos Cirúrgicos Cardíacos/tendências , Tratamento de Emergência/tendências , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Masculino , Sistema de Registros , Medição de Risco
10.
EuroIntervention ; 13(10): 1149-1156, 2017 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-28760721

RESUMO

AIMS: Transcatheter aortic valve implantation for a failing surgical bioprosthesis (TAV-in-SAV) has become an alternative for patients at high risk for redo surgical aortic valve replacement (redo-SAVR). Comparisons between these approaches are non-existent. This study aimed to compare clinical and echocardiographic outcomes of patients undergoing TAV-in-SAV versus redo-SAVR after accounting for baseline differences by propensity score matching. METHODS AND RESULTS: Patients from seven centres in Europe and Canada who had undergone either TAV-in-SAV (n=79) or redo-SAVR (n=126) were identified. Significant independent predictors used for propensity scoring were age, NYHA functional class, number of prior cardiac surgeries, urgent procedure, pulmonary hypertension, and COPD grade. Using a calliper range of ±0.05, a total of 78 well-matched patient pairs were found. All-cause mortality was similar between groups at 30 days (6.4% redo-SAVR vs. 3.9% TAV-in-SAV; p=0.49) and one year (13.1% redo-SAVR vs. 12.3% TAV-in-SAV; p=0.80). Both groups also showed similar incidences of stroke (0% redo-SAVR vs. 1.3% TAV-in-SAV; p=1.0) and new pacemaker implantation (10.3% redo-SAVR vs. 10.3% TAV-in-SAV; p=1.0). The incidence of acute kidney injury requiring dialysis was numerically lower in the TAV-in-SAV group (11.5% redo-SAVR vs. 3.8% TAV-in-SAV; p=0.13). The TAV-in-SAV group had a significantly shorter median total hospital stay (12 days redo-SAVR vs. 9 days TAV-in-SAV; p=0.001). CONCLUSIONS: Patients with aortic bioprosthesis failure treated with either redo-SAVR or TAV-in-SAV have similar 30-day and one-year clinical outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adulto , Idoso , Idoso de 80 Anos ou mais , Bioprótese , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
11.
EuroIntervention ; 13(7): 828-834, 2017 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-28320685

RESUMO

AIMS: The use of multiple geographical sites for randomised cardiovascular trials may lead to important heterogeneity in treatment effects. This study aimed to determine whether treatment effects from different geographical recruitment regions impacted significantly on five-year MACCE rates in the SYNTAX trial. METHODS AND RESULTS: Five-year SYNTAX results (n=1,800) were analysed for geographical variability by site and country for the effect of treatment (CABG vs. PCI) on MACCE rates. Fixed, random, and linear mixed models were used to test clinical covariate effects, such as diabetes, lesion characteristics, and procedural factors. Comparing five-year MACCE rates, the pooled odds ratio (OR) between study sites was 0.58 (95% CI: 0.47-0.71), and countries 0.59 (95% CI: 0.45-0.73). By homogeneity testing, no individual site (X2=93.8, p=0.051) or country differences (X2=25.7, p=0.080) were observed. For random effects models, the intraclass correlation was minimal (ICC site=5.1%, ICC country=1.5%, p<0.001), indicating minimal geographical heterogeneity, with a hazard ratio of 0.70 (95% CI: 0.59-0.83). Baseline risk (smoking, diabetes, PAD) did not influence regional five-year MACCE outcomes (ICC 1.3%-5.2%), nor did revascularisation of the left main vs. three-vessel disease (p=0.241), across site or country subgroups. For CABG patients, the number of arterial (p=0.49) or venous (p=0.38) conduits used also made no difference. CONCLUSIONS: Geographic variability has no significant treatment effect on MACCE rates at five years. These findings highlight the generalisability of the five-year outcomes of the SYNTAX study.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Angioplastia Coronária com Balão/métodos , Angiografia Coronária/métodos , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/tratamento farmacológico , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/métodos , Fatores de Risco , Resultado do Tratamento
12.
Can J Cardiol ; 33(2): 260-268, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28034581

RESUMO

BACKGROUND: Despite previously described feasibility, direct transcatheter aortic valve implantation (TAVI) with the Edwards SAPIEN S3 device (S3-THV) (Edwards Lifesciences, Irvine, CA) has not been compared with either a systematic or a selective predilation approach. METHODS: Patients undergoing predilation were divided into a systematic group (regardless of anatomic features) and a selective group (in the context of high valvular calcium burden). Both groups were matched in a 2:1 fashion to patients who underwent direct TAVI. Outcomes were assessed according to Valve Academic Research Consortium 2 (VARC-2) criteria. RESULTS: Two hundred eighty-one patients underwent TAVI with the S3-THV in our centre. Of these patients, 58 underwent predilation before device implantation (systematic, n = 26; selective, n = 32). Procedural success was achieved in all patients. Patients in the selective predilation group had severe valve calcification volume-more than double that of the systematic group (445 ± 306 mm3 vs 970 ± 578 mm3, respectively; P < 0.0001). There was a trend for less dilation after the procedure in the systematic group compared with the selective group (4% vs 19%, respectively; P = 0.09). Device malposition necessitating a second device to be implanted occurred in 3 cases of direct TAVI (5%) and in none of the patients undergoing predilation (P = not significant). Thirty-day and 1-year mortality rates were similar between the patients who underwent direct TAVI and their predilation counterparts. CONCLUSIONS: In patients with a moderate aortic valve calcification burden, direct TAVI appears to be feasible and safe. In those with high calcium burden, predilation should be considered after taking into account individual risk profiles.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Calcinose/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Calcinose/diagnóstico , Ecocardiografia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
13.
Int J Cardiol ; 220: 7-13, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27372037

RESUMO

BACKGROUND: Although the trans-radial approach (TR) has been applied to various subsets of patients in percutaneous coronary intervention, the feasibility, efficacy, acute procedural and long-term outcomes of TR versus trans-femoral approach (TF) for alcohol septal ablation (ASA) have not yet been determined. OBJECTIVES: The aim of this study was to compare the short and long-term outcomes of ASA with the TR approach compared to the TF approach. METHODS: We retrospectively analyzed 240 patients who underwent an ASA procedure at our institution from November 1999 to November 2015. The TR approach was performed in 172 cases and the TF approach in the remaining 68 cases. RESULTS: The use of TR approach progressively increased from 62% in 1999-2005 to 91% in 2011-2015 (p=0.0001). The TF and TR group had similar age, baseline NYHA class (NYHA 3 or 4) and mean left ventricular outflow tract peak gradient before ASA. Total contrast used (TR: 73.2±47.2ml; TF: 88.7±49.3ml, p=0.11), total radiation Air kerma area product (TR: 43.7±48.0Gycm(-2); TF: 55.9±48.2Gycm(-2); p=0.39) and peak left ventricular outflow tract gradient immediately after ASA (TR: 19.1±19.6mmHg; TF: 20.4±18.0mmHg, p=0.63) were similar in both groups. Procedural success was 91.9% and 91.2% in the TR and TF groups, respectively (p=0.53). At 30days, there was 2 intra-hospital death (1 in TF and 1 in TR), 1 major stroke in the TF group and 1 coronary artery dissection in the TR group. Vascular complications were less frequent in the TR group (0.58% vs. 7.3%; p=0.002). The mean length of follow-up was 4.56±4.34years (IQR 0.69-8.2; median 2.92years; maximum: 15.5years). By Kaplan-Meier estimate, the observed survival in the overall cohort was comparable to the expected survival for a sex and age-matched comparable general French population at 10years (86.9 vs. 83.6%, p=0.88). Survival was similar between the TR and TF group (92.1% vs. 89.7% at 6years, respectively; p=0.71). CONCLUSIONS: Alcohol septal ablation from the radial approach can be performed with similar acute and long-term success, but with lower vascular complications compared to the femoral approach.


Assuntos
Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter/métodos , Etanol/administração & dosagem , Artéria Femoral/cirurgia , Septos Cardíacos/cirurgia , Artéria Radial/cirurgia , Adulto , Idoso , Cateterismo Cardíaco/métodos , Cardiomiopatia Hipertrófica/diagnóstico , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
15.
EuroIntervention ; 12(8): e1011-e1020, 2016 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-26606733

RESUMO

AIMS: Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodality imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. METHODS AND RESULTS: A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. CONCLUSIONS: MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.


Assuntos
Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Músculos Papilares/diagnóstico por imagem , Disfunção Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Tomografia Computadorizada Multidetectores , Variações Dependentes do Observador , Seleção de Pacientes , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
EuroIntervention ; 12(8): e1021-e1030, 2016 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-26606734

RESUMO

AIMS: Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with mitral regurgitation at excessive risk for mitral valve surgery. Geometrical measurements of the mitral valvular complex may have implications for the design of TMVR devices and for patient selection. This study sought to quantify the dynamic geometry of the mitral valvular complex in patients with significant functional mitral regurgitation (FMR) using multi-slice computed tomography (MSCT). METHODS AND RESULTS: MSCT images were acquired in 32 patients with symptomatic, significant FMR. Two independent observers analysed image sets using a dedicated software package and a standard measurement methodology. In patients with FMR, the mean mitral annulus intercommissural and aorto-mural diameters were, respectively, 41.5±5.2 mm and 38.7±5.9 mm in systole, and were 41.5±4.4 mm and 40.0±4.7 mm in diastole. In patients without MR, the diameters were, respectively, 33.6±5.1 mm and 28.8±8.0 mm in systole, and 36.2±4.5 mm and 31.6±7.9 mm in diastole. The obstacle-free zone below the mitral annulus averaged more than 20.0 mm and varied by less than 1 mm between systole and diastole, which is not statistically significant. The aorto-mitral angle was 129.7±10.5° in systole and 131.0±9.4° in diastole. CONCLUSIONS: The mitral annulus is larger in dimension, more circular, and less dynamic in patients with FMR. The obstacle-free zone below the mitral annulus is relatively constant during the cardiac cycle. Measurements of the mitral valvular apparatus vary considerably between patients, which suggests that tridimensional imaging will play an important role in the sizing of TMVR devices.


Assuntos
Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Músculos Papilares/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Variações Dependentes do Observador , Seleção de Pacientes , Desenho de Prótese , Estudos Retrospectivos , Índice de Gravidade de Doença
17.
J Heart Valve Dis ; 19(4): 524-32, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20845902

RESUMO

BACKGROUND AND AIM OF THE STUDY: The purpose of this investigation was to evaluate both long-term functional status and quality of life (QoL) following valvular replacement surgery in octogenarians. The influence of gender and discharge location was also examined. METHODS: A total of 133 patients (age range: 80-89 years) who underwent surgical valve replacement between January 2003 and December 2006 was identified. Two questionnaires evaluating QoL (SF-12v2 and MLHFQ), as well as a demographic questionnaire, were sent to these patients. RESULTS: The response rate was 64.4%. Among the participants, the mean NYHA functional class improved from 2.7 to 1.4 after surgery. Men showed results similar to those of the age-matched general Canadian population on the mental and physical component scales of the SF-12v2. The data on women were similar to those of the general population on the physical component scale, but their scores were significantly lower on the mental component scale of the SF-12v2. Further analysis of the results comparing discharge location for each gender revealed that women discharged to a convalescence resource had significantly better QoL scores than those discharged to home with regards to the physical component scale of the SF-12v2, the total score of the MLHFQ, and the physical dimension score of the MLHFQ. CONCLUSION: Patients aged > or = 80 years benefit from heart valve replacement surgery in terms of both QoL and functional status. Women may be at increased risk of a decline in their emotional well-being and, postoperatively, may benefit more from convalescence than from discharge to home.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Qualidade de Vida , Fatores Etários , Idoso de 80 Anos ou mais , Estudos Transversais , Emoções , Feminino , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/psicologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/psicologia , Humanos , Masculino , Alta do Paciente , Quebeque , Recuperação de Função Fisiológica , Fatores Sexuais , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA