Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 23(3): 650-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22983281

RESUMO

OBJECTIVES: Performance evaluation of a fully automated system for calculating computed tomography (CT) coronary artery calcium scores from contrast medium-enhanced coronary CT angiography (cCTA) studies. METHODS: One hundred and twenty-seven patients (58 ± 11 years, 71 men) who had undergone cCTA as well as an unenhanced CT calcium scoring study where included. Calcium scores were computed from cCTA by an automated image processing algorithm and compared with calcium scores obtained by standard manual assessment of unenhanced CT calcium scoring studies. Results were compared vis-a-vis (1) absolute calcium score values, (2) age-, gender- and race-dependent percentiles, and (3) commonly used calcium score risk classification categories. RESULTS: One hundred and nineteen out of 127 (93.7%) studies were successfully processed. Mean Agatston calcium score values obtained by traditional non-contrast CT calcium scoring studies and derived from contrast medium-enhanced cCTA did not significantly differ (235.6 ± 430.5 vs 262.0 ± 499.5; P > 0.05). Calcium score risk categories and Multi-Ethnic Study of Atherosclerosis (MESA) percentiles showed very high correlation (Spearman rank correlation coefficient = 0.97, P < 0.0001/0.95, P < 0.0001) between the two approaches. CONCLUSIONS: Calcium score values automatically computed from cCTA are highly correlated with standard unenhanced CT calcium scoring studies. These results suggest a radiation dose- and time-saving potential when deriving calcium scores from cCTA studies without a preceding unenhanced CT calcium scoring study.


Assuntos
Algoritmos , Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Iohexol/análogos & derivados , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Calcinose/complicações , Meios de Contraste , Doença da Artéria Coronariana/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
2.
Eur Radiol ; 23(5): 1306-15, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23207869

RESUMO

OBJECTIVES: To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. METHODS: Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. RESULTS: Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. CONCLUSIONS: IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. KEY POINTS: • Iterative reconstruction techniques significantly improve non-invasive cardiovascular CT in children. • Using half traditional radiation dose image quality is higher with iterative reconstruction. • Iterative reconstruction techniques may allow further radiation reductions in paediatric cardiovascular CT.


Assuntos
Doenças Cardiovasculares/congênito , Doenças Cardiovasculares/diagnóstico por imagem , Angiografia Coronária/métodos , Doses de Radiação , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Algoritmos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Eur Radiol ; 23(1): 125-32, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22777622

RESUMO

OBJECTIVES: Comparison of coronary artery stent assessment with cardiac CT angiography (cCTA) using traditional filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE), in both full- and half-radiation dose image data. METHODS: Dual-source cCTA studies of 37 implanted stents were reconstructed at full- and half-radiation dose with FBP and SAFIRE. Half-dose data were based on projections from one DSCT detector. In-stent noise, signal-to-noise ratio (SNR), and stent-lumen attenuation increase ratio (SAIR) were measured and image quality graded. Stent volumes were measured to gauge severity of beam hardening artefacts. RESULTS: Full-dose SAFIRE reconstructions were superior to full-dose FBP vis-à-vis in-stent noise (21.2 ± 6.6 vs. 35.7 ± 17.5; P < 0.05), SNR (22.1 ± 8.6 vs. 14.3 ± 6.7; P < 0.05), SAIR (19.6 ± 17.6 vs. 33.4 ± 20.4%; P < 0.05), and image quality (4.2 ± 0.86 vs. 3.5 ± 1.0; P < 0.05). Stent volumes were lower measured with SAFIRE (119.9 ± 53.7 vs. 129.8 ± 65.0 mm(3); P > 0.05). Comparing half-dose SAFIRE with full-dose FBP, in-stent noise (26.7 ± 13.0 vs. 35.7 ± 17.5; P < 0.05) and SNR (18.2 ± 6.9 vs. 14.3 ± 6.7; P < 0.05) improved significantly. SAIR (31.6 ± 24.3 vs. 33.4 ± 20.4%; P > 0.05), stent volume (129.6 ± 57.3 vs. 129.8 ± 65.0 mm(3); P > 0.05), and image quality (3.5 ± 1.0 vs. 3.7 ± 1.1; P > 0.05) did not differ. Radiation dose decreased from 8.7 ± 5.2 to 4.3 ± 2.6 mSv. CONCLUSIONS: Iterative reconstruction significantly improves imaging of coronary artery stents by CT compared with FBP, even with half-radiation-dose data.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/cirurgia , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Stents , Tomografia Computadorizada por Raios X/métodos , Idoso , Artefatos , Distribuição de Qui-Quadrado , Comorbidade , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Estudos Retrospectivos , Razão Sinal-Ruído , Estatísticas não Paramétricas
4.
AJR Am J Roentgenol ; 199(6): 1402-9, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23169737

RESUMO

OBJECTIVE: The objective of our study was to evaluate radiation dose and quantitative image quality parameters at high-pitch CT angiography (CTA) of the aorta compared with conventional CTA. MATERIALS AND METHODS: We studied the examinations of 110 patients (65 men and 45 women; mean age ± SD, 64 ± 15 years) who had undergone CTA of the entire aorta on a second-generation dual-source CT system; 50 examinations were performed in high-pitch mode. The mean arterial attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) were calculated for the high-pitch CTA and conventional CTA groups. Radiation exposures were compared. RESULTS: All studies were considered of diagnostic quality. At high-pitch CTA, the mean tube voltage and tube current-exposure time product were 118 ± 7 kV (SD) and 197 ± 78 mAs compared with 120 ± 1 kV and 258 ± 78 mAs, respectively, at conventional CTA (p < 0.05). The mean volume CT dose index, dose-length product, and effective dose were 8.1 ± 2.4 mGy, 561.1 ± 178.6 mGy × cm, and 9.6 ± 3.0 mSv at high-pitch CTA and 18.3 ± 7.7 mGy, 1162.6 ± 480.1 mGy × cm, and 19.8 ± 8.2 mSv at conventional CTA (p < 0.001). Attenuation was similar for both protocols, whereas significantly less contrast medium was injected for high-pitch CTA than for standard-pitch CTA (87.3 ± 16 mL vs 97.9 ± 16 mL, respectively; p < 0.01). The SNR and CNR were significantly lower in the high-pitch CTA examinations (p < 0.01), whereas the FOM was nonsignificantly higher. Twenty patients underwent both high-pitch CTA and conventional CTA, with a 45% reduction in radiation dose (p < 0.001). CONCLUSION: High-pitch CTA of the aorta yields 45-50% reduction of radiation exposure as well as contrast medium savings with maintained vessel attenuation.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Aortografia/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Angiografia Digital , Índice de Massa Corporal , Distribuição de Qui-Quadrado , Meios de Contraste , Feminino , Humanos , Iohexol , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA