Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38837348

RESUMO

OBJECTIVES: To assess the accuracy of a deep learning-based algorithm for fully automated detection of thoracic aortic calcifications in chest computed tomography (CT) with a focus on the aortic clamping zone. METHODS: We retrospectively included 100 chest CT scans from 91 patients who were examined on second- or third-generation dual-source scanners. Subsamples comprised 47 scans with an electrocardiogram-gated aortic angiography and 53 unenhanced scans. A deep learning model performed aortic landmark detection and aorta segmentation to derive 8 vessel segments. Associated calcifications were detected and their volumes measured using a mean-based density thresholding. Algorithm parameters (calcium cluster size threshold, aortic mask dilatation) were varied to determine optimal performance for the upper ascending aorta that encompasses the aortic clamping zone. A binary visual rating served as a reference. Standard estimates of diagnostic accuracy and inter-rater agreement using Cohen's Kappa were calculated. RESULTS: Thoracic aortic calcifications were observed in 74% of patients with a prevalence of 27-70% by aorta segment. Using different parameter combinations, the algorithm provided binary ratings for all scans and segments. The best performing parameter combination for the presence of calcifications in the aortic clamping zone yielded a sensitivity of 93% and a specificity of 82%, with an area under the receiver operating characteristic curve of 0.874. Using these parameters, the inter-rater agreement ranged from κ 0.66 to 0.92 per segment. CONCLUSIONS: Fully automated segmental detection of thoracic aortic calcifications in chest CT performs with high accuracy. This includes the critical preoperative assessment of the aortic clamping zone.


Assuntos
Aorta Torácica , Doenças da Aorta , Aprendizado Profundo , Tomografia Computadorizada por Raios X , Calcificação Vascular , Humanos , Aorta Torácica/diagnóstico por imagem , Estudos Retrospectivos , Feminino , Masculino , Calcificação Vascular/diagnóstico por imagem , Idoso , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Doenças da Aorta/diagnóstico por imagem , Algoritmos , Idoso de 80 Anos ou mais
2.
J Thorac Imaging ; 37(3): 154-161, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34387227

RESUMO

OBJECTIVES: The aim of the study is to investigate the performance of artificial intelligence (AI) convolutional neural networks (CNN) in detecting lung nodules on chest computed tomography of patients with complex lung disease, and demonstrate its noninferiority when compared against an experienced radiologist through clinically relevant assessments. METHODS: A CNN prototype was used to retrospectively evaluate 103 complex lung disease cases and 40 control cases without reported nodules. Computed tomography scans were blindly evaluated by an expert thoracic radiologist; a month after initial analyses, 20 positive cases were re-evaluated with the assistance of AI. For clinically relevant applications: (1) AI was asked to classify each patient into nodules present or absent and (2) AI results were compared against standard radiology reports. Standard statistics were performed to determine detection performance. RESULTS: AI was, on average, 27 seconds faster than the expert and detected 8.4% of nodules that would have been missed. AI had a sensitivity of 67.7%, similar to an accuracy reported for experienced radiologists. AI correctly classified each patient (nodules present/absent) with a sensitivity of 96.1%. When matched against radiology reports, AI performed with a sensitivity of 89.4%. Control group assessment demonstrated an overall specificity of 82.5%. When aided by AI, the expert decreased the average assessment time per case from 2:44 minutes to 35.7 seconds, while reporting an overall increase in confidence. CONCLUSION: In a group of patients with complex lung disease, the sensitivity of AI is similar to an experienced radiologist and the tool helps detect previously missed nodules. AI also helps experts analyze for lung nodules faster and more confidently, a feature that is beneficial to patients and favorable to hospitals due to increased patient load and need for shorter turnaround times.


Assuntos
Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Inteligência Artificial , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade
3.
Quant Imaging Med Surg ; 11(10): 4245-4257, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34603980

RESUMO

BACKGROUND: Manually performed diameter measurements on ECG-gated CT-angiography (CTA) represent the gold standard for diagnosis of thoracic aortic dilatation. However, they are time-consuming and show high inter-reader variability. Therefore, we aimed to evaluate the accuracy of measurements of a deep learning-(DL)-algorithm in comparison to those of radiologists and evaluated measurement times (MT). METHODS: We retrospectively analyzed 405 ECG-gated CTA exams of 371 consecutive patients with suspected aortic dilatation between May 2010 and June 2019. The DL-algorithm prototype detected aortic landmarks (deep reinforcement learning) and segmented the lumen of the thoracic aorta (multi-layer convolutional neural network). It performed measurements according to AHA-guidelines and created visual outputs. Manual measurements were performed by radiologists using centerline technique. Human performance variability (HPV), MT and DL-performance were analyzed in a research setting using a linear mixed model based on 21 randomly selected, repeatedly measured cases. DL-algorithm results were then evaluated in a clinical setting using matched differences. If the differences were within 5 mm for all locations, the cases was regarded as coherent; if there was a discrepancy >5 mm at least at one location (incl. missing values), the case was completely reviewed. RESULTS: HPV ranged up to ±3.4 mm in repeated measurements under research conditions. In the clinical setting, 2,778/3,192 (87.0%) of DL-algorithm's measurements were coherent. Mean differences of paired measurements between DL-algorithm and radiologists at aortic sinus and ascending aorta were -0.45±5.52 and -0.02±3.36 mm. Detailed analysis revealed that measurements at the aortic root were over-/underestimated due to a tilted measurement plane. In total, calculated time saved by DL-algorithm was 3:10 minutes/case. CONCLUSIONS: The DL-algorithm provided coherent results to radiologists at almost 90% of measurement locations, while the majority of discrepent cases were located at the aortic root. In summary, the DL-algorithm assisted radiologists in performing AHA-compliant measurements by saving 50% of time per case.

4.
Quant Imaging Med Surg ; 11(6): 2486-2498, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34079718

RESUMO

BACKGROUND: Radiology reporting of emergency whole-body computed tomography (CT) scans is time-critical and therefore involves a significant risk of pathology under-detection. We hypothesize a relevant number of initially missed secondary thoracic findings that would have been detected by an artificial intelligence (AI) software platform including several pathology-specific AI algorithms. METHODS: This retrospective proof-of-concept-study consecutively included 105 shock-room whole-body CT scans. Image data was analyzed by platform-bundled AI-algorithms, findings were reviewed by radiology experts and compared with the original radiologist's reports. We focused on secondary thoracic findings, such as cardiomegaly, coronary artery plaques, lung lesions, aortic aneurysms and vertebral fractures. RESULTS: We identified a relevant number of initially missed findings, with their quantification based on 105 analyzed CT scans as follows: up to 25 patients (23.8%) with cardiomegaly or borderline heart size, 17 patients (16.2%) with coronary plaques, 34 patients (32.4%) with aortic ectasia, 2 patients (1.9%) with lung lesions classified as "recommended to control" and 13 initially missed vertebral fractures (two with an acute traumatic origin). A high number of false positive or non-relevant AI-based findings remain problematic especially regarding lung lesions and vertebral fractures. CONCLUSIONS: We consider AI to be a promising approach to reduce the number of missed findings in clinical settings with a necessary time-critical radiological reporting. Nevertheless, algorithm improvement is necessary focusing on a reduction of "false positive" findings and on algorithm features assessing the finding relevance, e.g., fracture age or lung lesion malignancy.

5.
J Thorac Imaging ; 35 Suppl 1: S28-S34, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32235188

RESUMO

OBJECTIVES: The objective of this study was to evaluate an artificial intelligence (AI)-based prototype algorithm for the fully automated per lobe segmentation and emphysema quantification (EQ) on chest-computed tomography as it compares to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) severity classification of chronic obstructive pulmonary disease (COPD) patients. METHODS: Patients (n=137) who underwent chest-computed tomography acquisition and spirometry within 6 months were retrospectively included in this Institutional Review Board-approved and Health Insurance Portability and Accountability Act-compliant study. Patient-specific spirometry data, which included forced expiratory volume in 1 second, forced vital capacity, and the forced expiratory volume in 1 second/forced vital capacity ratio (Tiffeneau-Index), were used to assign patients to their respective GOLD stage I to IV. Lung lobe segmentation was carried out using AI-RAD Companion software prototype (Siemens Healthineers), a deep convolution image-to-image network and emphysema was quantified in each lung lobe to detect the low attenuation volume. RESULTS: A strong correlation between the whole-lung-EQ and the GOLD stages was found (ρ=0.88, P<0.0001). The most significant correlation was noted in the left upper lobe (ρ=0.85, P<0.0001), and the weakest in the left lower lobe (ρ=0.72, P<0.0001) and right middle lobe (ρ=0.72, P<0.0001). CONCLUSIONS: AI-based per lobe segmentation and its EQ demonstrate a very strong correlation with the GOLD severity stages of COPD patients. Furthermore, the low attenuation volume of the left upper lobe not only showed the strongest correlation to GOLD severity but was also able to most clearly distinguish mild and moderate forms of COPD. This is particularly relevant due to the fact that early disease processes often elude conventional pulmonary function diagnostics. Earlier detection of COPD is a crucial element for positively altering the course of disease progression through various therapeutic options.


Assuntos
Inteligência Artificial , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Fumantes/estatística & dados numéricos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/complicações , Enfisema Pulmonar/complicações , Radiografia Torácica/métodos , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
6.
Eur J Radiol ; 89: 27-32, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28267545

RESUMO

X-Ray Phase-Contrast (XPC) imaging is a novel technology with a great potential for applications in clinical practice, with breast imaging being of special interest. This work introduces an intuitive methodology to combine and visualize relevant diagnostic features, present in the X-ray attenuation, phase shift and scattering information retrieved in XPC imaging, using a Fourier domain fusion algorithm. The method allows to present complementary information from the three acquired signals in one single image, minimizing the noise component and maintaining visual similarity to a conventional X-ray image, but with noticeable enhancement in diagnostic features, details and resolution. Radiologists experienced in mammography applied the image fusion method to XPC measurements of mastectomy samples and evaluated the feature content of each input and the fused image. This assessment validated that the combination of all the relevant diagnostic features, contained in the XPC images, was present in the fused image as well.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Análise de Fourier , Processamento de Imagem Assistida por Computador/métodos , Mamografia/métodos , Adulto , Algoritmos , Feminino , Humanos , Reprodutibilidade dos Testes , Raios X
7.
Magn Reson Imaging ; 36: 24-31, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27742434

RESUMO

PURPOSE: To compare compressed diffusion spectrum imaging (CS-DSI) with diffusion tensor imaging (DTI) in patients with intracranial masses. We hypothesized that CS-DSI would provide superior visualization of the motor and language tracts. MATERIALS AND METHODS: We retrospectively analyzed 25 consecutive patients with intracranial masses who underwent DTI and CS-DSI for preoperative planning. Directionally-encoded anisotropy maps, and streamline hand corticospinal motor tracts and arcuate fasciculus language tracts were graded according to a 3-point scale. Tract counts, anisotropy, and lengths were also calculated. Comparisons were made using exact marginal homogeneity, McNemar's and Wilcoxon signed-rank tests. RESULTS: Readers preferred the CS-DSI over DTI anisotropy maps in 92% of the cases, and the CS-DSI over DTI tracts in 84%. The motor tracts were graded as excellent in 80% of cases for CS-DSI versus 52% for DTI; 58% of the motor tracts graded as acceptable in DTI were graded as excellent in CS-DSI (p=0.02). The language tracts were graded as excellent in 68% for CS-DSI versus none for DTI; 78% of the language tracts graded as acceptable by DTI were graded as excellent by CS-DSI (p<0.001). CS-DSI demonstrated smaller normalized mean differences than DTI for motor tract counts, anisotropy and language tract counts (p≤0.01). CONCLUSION: CS-DSI was preferred over DTI for the evaluation of motor and language white matter tracts in patients with intracranial masses. Results suggest that CS-DSI may be more useful than DTI for preoperative planning purposes.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
8.
Biomed Opt Express ; 7(2): 381-91, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26977347

RESUMO

Differential phase-contrast X-ray imaging using a Talbot-Lau interferometer has recently shown promising results for applications in medical imaging. However, reducing the applied radiation dose remains a major challenge. In this study, we consider the realization of a Talbot-Lau interferometer in a high Talbot order to increase the signal-to-noise ratio for low-dose applications. The quantitative performance of π and π/2 systems at high Talbot orders is analyzed through simulations, and the design energy and X-ray spectrum are optimized for mammography. It is found that operation even at very high Talbot orders is feasible and beneficial for image quality. As long as the X-ray spectrum is matched to the visibility spectrum, the SNR continuously increases with the Talbot order for π-systems. We find that the optimal X-ray spectra and design energies are almost independent of the Talbot order and that the overall imaging performance is robust against small variations in these parameters. Discontinuous spectra, such as that from molybdenum, are less robust because the characteristic lines may coincide with minima in the visibility spectra; however, they may offer slightly better performance. We verify this hypothesis by realizing a prototype system with a mean fringe visibility of above 40% at the seventh Talbot order. With this prototype, a proof-of-principle measurement of a freshly dissected breast at reasonable compression to 4 cm is conducted with a mean glandular dose of only 3 mGy but with a high SNR.

9.
Magn Reson Med ; 69(5): 1209-16, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22648928

RESUMO

Within the last decade hyperpolarized [1-13C] pyruvate chemical-shift imaging has demonstrated impressive potential for metabolic MR imaging for a wide range of applications in oncology, cardiology, and neurology. In this work, a highly efficient pulse sequence is described for time-resolved, multislice chemical shift imaging of the injected substrate and obtained downstream metabolites. Using spectral-spatial excitation in combination with single-shot spiral data acquisition, the overall encoding is evenly distributed between excitation and signal reception, allowing the encoding of one full two-dimensional metabolite image per excitation. The signal-to-noise ratio can be flexibly adjusted and optimized using lower flip angles for the pyruvate substrate and larger ones for the downstream metabolites. Selectively adjusting the excitation of the down-stream metabolites to 90° leads to a so-called "saturation-recovery" scheme with the detected signal content being determined by forward conversion of the available pyruvate. In case of repetitive excitations, the polarization is preserved using smaller flip angles for pyruvate. Metabolic exchange rates are determined spatially resolved from the metabolite images using a simplified two-site exchange model. This novel contrast is an important step toward more quantitative metabolic imaging. Goal of this work was to derive, analyze, and implement this "saturation-recovery metabolic exchange rate imaging" and demonstrate its capabilities in four rats bearing subcutaneous tumors.


Assuntos
Alanina/metabolismo , Bicarbonatos/metabolismo , Ácido Láctico/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Neoplasias Experimentais/metabolismo , Ácido Pirúvico/farmacocinética , Animais , Isótopos de Carbono/farmacocinética , Linhagem Celular Tumoral , Feminino , Taxa de Depuração Metabólica , Neoplasias Experimentais/diagnóstico , Prótons , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Ratos Endogâmicos F344
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA