Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
J Endovasc Ther ; : 15266028241246648, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38651857

RESUMO

INTRODUCTION: Chimney technique (chimney graft in abdominal aortic aneurysm repair [ChEVAR]) can be used to treat patients with pararenal aortic aneurysm unfit for open surgery and not suitable for custom-made fenestrated endograft. Since almost 1 in 5 patients undergo a reintervention within 3 years, features associated with higher risk of complications need to be investigated to tailor the follow-up schedule to each patient. The aim of our study was to assess the impact of mural thrombus in the pararenal aorta on perioperative and follow-up complications after ChEVAR. METHODS: All consecutive patients undergoing ChEVAR at our center from 2015 to 2022 were included in this retrospective study. Collected variables included number of target vessels, stent graft size, presence, and severity of mural thrombus in pararenal aorta, which was reported with a scoring system from 0 to 10 based on thrombus type, thickness area, and circumferenceAnalyzed outcomes included perioperative and follow-up complications. RESULTS: Thirty-one patients underwent ChEVAR during the study period. In 4 patients the indication for ChEVAR was type 1A endoleak after a previous endovascular aneurysm repair (EVAR). The number of target vessels was 1 in 17 patients (55%), 2 in 12 (39%), 3 in 1 (3%), and 4 in 1 (%). The mean mural thrombus score was 5.9. Complications were the following: type 1A endoleak in 4 cases (13%), chimney stent complications in 7 cases (23%) (including partial or total thrombosis, intrastent stenosis, displacement), renal function worsening during follow-up in 8 cases (26%). Overall survival was 90% at 2 years. Patients with severe mural thrombus showed lower freedom from ChEVAR-related complications (28% vs 59% at 2 years, p=0.023). CONCLUSIONS: The presence of severe pararenal aortic mural thrombus was associated with lower freedom from ChEVAR-related complications in patients undergoing ChEVAR for pararenal aortic aneurysm repair. Further research with a larger number of patients is required to confirm these results. CLINICAL IMPACT: The analysis of severity of mural thrombus in pararenal aorta, which was reported with a scoring system from 0 to 10 based on thrombus type, thickness area and circumference, can be useful and can be represent an important predictor element for complications in patient submitted to Chimney tecnique; in fact the presence of severe pararenal aortic mural thrombus was associated with lower freedom from ChEVAR-related complications in patients undergoing ChEVAR for pararenal aortic aneurysm repair. Then, in patient with pararenal aortic aneurysm, a preoperative evaluation could be focused on severity of mural thrombus to minimize the complications in ChEVAR tecnique or to change the surgical strategy.

2.
Chem Biodivers ; 21(3): e202302071, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38230843

RESUMO

Continuing our studies in the field of new heterocyclic compounds with biological interest, herein we report the synthesis and anticancer activity of new N- and S-substituted derivatives of tetracyclic pyrido[3',2' : 4,5]thieno[3,2-d]pyrimidines. In this regard, starting from the thieno[2,3-b]pyridine-2-carboxylates, the corresponding 8(9)-aminopyrido[3',2' : 4,5]thieno[3,2-d]pyrimidin-7(8)-ones, as well as chloro derivatives were obtained. Based on the latter, amino, hydrazino and S-alkyl derivatives of pyrido[3',2' : 4,5]thieno[3,2-d]pyrimidines were synthesized subsequently. The current study focuses on identifying the potential of thieno[3,2-d]pyrimidine derivatives primarily towards ATR kinase inhibition, through computational predictions, followed by synthesis and cancer cell viability studies, along with an aim to develop the core as PIKK inhibitors for cancer therapy.


Assuntos
Antineoplásicos , Neoplasias , Relação Estrutura-Atividade , Pirimidinas/farmacologia , Piridinas , Antineoplásicos/farmacologia
3.
J Thorac Cardiovasc Surg ; 165(1): 4-13.e1, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-33612294

RESUMO

OBJECTIVE: The study objective was to analyze the outcomes of thoracic endovascular aortic repair performed for complicated and uncomplicated acute type B aortic dissections. METHODS: Patients from WL Gore's Global Registry for Endovascular Aortic Treatment who underwent thoracic endovascular aortic repair for acute type B aortic dissections were included, and data were retrospectively analyzed. RESULTS: Of 5014 patients enrolled in the Global Registry for Endovascular Aortic Treatment, 172 underwent thoracic endovascular aortic repair for acute type B aortic dissections. Of these repairs, 102 were for complicated acute type B aortic dissections and 70 were for uncomplicated acute type B aortic dissections. There were 46 (45.1%) procedures related to aortic branch vessels versus 15 (21.4%) in complicated type B aortic dissections and uncomplicated type B aortic dissections (P = .002). The mean length of stay was 14.3 ± 10.6 days (median, 11; range, 2-75) versus 9.8 ± 7.9 days (median, 8; range, 0-42) in those with complicated type B aortic dissections versus those with uncomplicated acute type B aortic dissections (P < .001). Thirty-day mortality was not different between groups (complicated type B aortic dissections 2.9% vs uncomplicated acute type B aortic dissections 1.4%, P = .647), as well as aortic complications (8.8% vs 5.7%, P = .449). Aortic event-free survival was 62.9% ± 37.1% versus 70.6% ± 29.3% at 3 years (P = .696). CONCLUSIONS: In the Global Registry for Endovascular Aortic Treatment, thoracic endovascular aortic repair results for complicated type B aortic dissections versus uncomplicated acute type B aortic dissections showed that 30-day mortality and perioperative complications were equally low for both. The midterm outcome was positive. These data confirm that thoracic endovascular aortic repair as the first-line strategy for treating complicated type B dissections is associated with a low risk of complications. Further studies with longer follow-up are necessary to define the role of thoracic endovascular aortic repair in uncomplicated acute type B dissections compared with medical therapy. However, in the absence of level A evidence from randomized trials, results of the uncomplicated acute type B aortic dissection patient cohort treated with thoracic endovascular aortic repair from registries are important to understand the related risk and benefit.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Fatores de Risco
4.
Molecules ; 27(14)2022 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-35889508

RESUMO

Despite extensive studies and the great variety of existing anticancer agents, cancer treatment remains an aggravating and challenging problem. Therefore, the development of novel anticancer drugs with a better therapeutic profile and fewer side effects to combat this persistent disease is still necessary. In this study, we report a novel series of benzothiazole and chromone derivatives that were synthesized and evaluated for their anticancer activity as an inhibitor of ATR kinase, a master regulator of the DDR pathway. The cell viability of a set of 25 compounds was performed using MTT assay in HCT116 and HeLa cell lines, involving 72 h incubation of the compounds at a final concentration of 10 µM. Cells incubated with compounds 2c, 7h and 7l were found to show viability ≤50%, and were taken forward for dose-response studies. Among the tested compounds, three of them (2c, 7h and 7l) showed higher potency, with compound 7l exhibiting the best IC50 values in both the cell lines. Compounds 2c and 7l were found to be equally cytotoxic towards both the cell lines, namely, HCT116 and HeLa, while compound 7h showed better cytotoxicity towards HeLa cell line. For these three compounds, an immunoblot assay was carried out in order to analyze the inhibition of phosphorylation of Chk1 at Ser 317 in HeLa and HCT116 cells. Compound 7h showed inhibition of pChk1 at Ser 317 in HeLa cells at a concentration of 3.995 µM. Further analysis for Chk1 and pChk1 expression was carried out in Hela cells by treatment against all the three compounds at a range of concentrations of 2, 5 and 10 µM, wherein compound 7h showed Chk1 inhibition at 2 and 5 µM, while pChk1 expression was observed for compound 7l at a concentration of 5 µM. To support the results, the binding interactions of the compounds with the ATR kinase domain was studied through molecular docking, wherein compounds 2c, 7h and 7l showed binding interactions similar to those of Torin2, a known mTOR/ATR inhibitor. Further studies on this set of molecules is in progress for their specificity towards the ATR pathway.


Assuntos
Antineoplásicos , Cromonas , Antineoplásicos/química , Antineoplásicos/farmacologia , Proteínas Mutadas de Ataxia Telangiectasia , Benzotiazóis/farmacologia , Proliferação de Células , Cromonas/farmacologia , Relação Dose-Resposta a Droga , Ensaios de Seleção de Medicamentos Antitumorais , Células HeLa , Humanos , Simulação de Acoplamento Molecular , Estrutura Molecular , Inibidores de Proteínas Quinases/química , Inibidores de Proteínas Quinases/farmacologia , Relação Estrutura-Atividade
5.
Int Angiol ; 41(2): 110-117, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35112823

RESUMO

BACKGROUND: Residual type B aortic dissection (R-TBAD) is a challenging kind of disease affecting an increasing number of patients. Management of R-TBAD has not been specifically addressed in current literature and many of those patients are not eligible for endovascular treatment. Aim of the study was to evaluate the efficacy and feasibility of a specifically conceived procedure the "saguaro branched graft technique" to treat R-TBAD distal to a proximal stent-graft. METHODS: Data of patients treated between 2015 and 2019 were prospectively collected and retrospectively analyzed. Indication for surgery was R-TBAD with chronic malperfusion, aortic enlargement >55 mm or rapid growth, and symptomatic aortic enlargement. A Dacron graft with four branches has been tailored on the back table by implanting two bifurcated grafts to a tube or bifurcated graft. After left thoracoabdominal incision the proximal endograft has been used as a solid starting point for the distal branched graft. Sequential revascularization of the visceral vessels was performed step by step by suturing each artery outside the aneurysm before opening the distal aorta, while a continued retrograde aortic and visceral perfusion was maintained by a left pump atrio-femoral bypass. After that all visceral branches had been regularly perfused from above, the thoraco-abdominal aorta was open and repaired. Outcome measures were 30-day mortality and 30-day major complications as were long-term all-cause mortality, aorta-related mortality, reintervention and patency rates of the branches. RESULTS: Thirteen patients with R-TBAD were treated during the study period. Indication for surgery was chronic malperfusion in one patient (7.7%), aortic enlargement >55 mm or rapid growth in 9 patients (69.2%), persistent pain with aortic enlargement ≥50 mm in 3 patients (23.1%). All patients were considered not eligible for endovascular repair. At 30-days no deaths or re-interventions occurred and major complications including acute cardiovascular events and renal function impairment were not reported; one patient (7.7%) developed postoperative paraplegia. At a mean follow-up period of 19.6±10.2 (range, 8-48) months, reintervention and mortality rates were null. Visceral malperfusion and late-onset renal failure were not reported, and all visceral branches were still patent. CONCLUSIONS: Despite the potential high risk of open surgery, the "saguaro branched graft technique" appears to be a safe surgical solution for R-TBAD.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/métodos , Humanos , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
6.
J Vasc Access ; 23(4): 524-531, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33726627

RESUMO

OBJECTIVE: To assess and compare the maturation rate of the native radiocephalic arteriovenous fistula (RC-AVF) created with and without a nitinol external support (VasQ™ Laminate Medical Technologies Ltd, Tel Aviv, Israel). METHODS: Data of all consecutive patients who underwent the creation of native RC-AVFs at our center between October 2018 and January 2020 was prospectively collected and retrospectively analyzed.Selected patients who had a suitable vein and a radial artery with triphasic flow at preoperative duplex ultrasound exam and were selected for the creation of a radiocephalic fistula were included. Exclusion criteria were: malignant tumors, acute renal failure, previous upper limb revascularization, and septic status. Patency and maturation, vein, and artery diameter and blood flow rate were assessed at the following intervals: post-operatively, 24 h post-operatively, 1 month, 3 months, and 6 months post-operatively. RESULTS: Forty-nine patients (31 males, mean age 65.7 years old) were included. Patients who received VasQ™ devices were 25 (VasQ group), the other 24 formed the control group. All patients underwent radio-cephalic AVF placement (21 on the wrist, 20 on the forearm, 8 on the proximal forearm). There were no perioperative complications and fatalities. At 1, 3, and 6 months, primary patency rates were 96 ± 4%, 96 ± 4%, 91 ± 6% (VasQ group) versus 87 ± 7%, 87 ± 7%, 80 ± 9% (control group, P 0.17), secondary patency rates were 96 ± 4%, 96 ± 4%, 91 ± 6% (VasQ group) versus 95 ± 4%, 90 ± 7%, 90 ± 7% (control group, P 0.79). A significantly larger vein diameter increase postoperatively (P 0.009) and a greater maturation rate (96% vs 74%, p 0.044) were found in the VasQ group compared to the control group. CONCLUSIONS: The use of the VasQ™ device was associated with higher maturation rates and larger vein diameters postoperatively. The patency rates were slightly higher but not significantly. Further studies are needed to confirm these findings.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Idoso , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Antebraço , Humanos , Masculino , Diálise Renal , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Extremidade Superior/irrigação sanguínea , Grau de Desobstrução Vascular
7.
Molecules ; 26(19)2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34641590

RESUMO

In the few last years, nanosystems have emerged as a potential therapeutic approach to improve the efficacy and selectivity of many drugs. Cyclodextrins (CyDs) and their nanoparticles have been widely investigated as drug delivery systems. The covalent functionalization of CyD polymer nanoparticles with targeting molecules can improve the therapeutic potential of this family of nanosystems. In this study, we investigated cross-linked γ- and ß-cyclodextrin polymers as carriers for doxorubicin (ox) and oxaliplatin (Oxa). We also functionalized γ-CyD polymer bearing COOH functionalities with arginine-glycine-aspartic or arginine moieties for targeting the integrin receptors of cancer cells. We tested the Dox and Oxa anti-proliferative activity in the presence of the precursor polymer with COOH functionalities and its derivatives in A549 (lung, carcinoma) and HepG2 (liver, carcinoma) cell lines. We found that CyD polymers can significantly improve the antiproliferative activity of Dox in HepG2 cell lines only, whereas the cytotoxic activity of Oxa resulted as enhanced in both cell lines. The peptide or amino acid functionalized CyD polymers, loaded with Dox, did not show any additional effect compared to the precursor polymer. Finally, studies of Dox uptake showed that the higher antiproliferative activity of complexes correlates with the higher accumulation of Dox inside the cells. The results show that CyD polymers could be used as carriers for repositioning classical anticancer drugs such as Dox or Oxa to increase their antitumor activity.


Assuntos
Antineoplásicos/uso terapêutico , Celulose/uso terapêutico , Ciclodextrinas/uso terapêutico , Doxorrubicina/uso terapêutico , Sistemas de Liberação de Medicamentos/métodos , Nanopartículas/uso terapêutico , Oxaliplatina/uso terapêutico , Células A549 , Motivos de Aminoácidos , Antineoplásicos/química , Proliferação de Células/efeitos dos fármacos , Celulose/química , Ciclodextrinas/química , Doxorrubicina/química , Portadores de Fármacos/química , Células Hep G2 , Humanos , Nanopartículas/química , Oxaliplatina/química , beta-Ciclodextrinas/química , beta-Ciclodextrinas/uso terapêutico , gama-Ciclodextrinas/química , gama-Ciclodextrinas/uso terapêutico
8.
Ann Vasc Surg ; 68: 426-433, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32428644

RESUMO

BACKGROUND: The aim of this study was to find out if intra-arterial intraoperative iloprost administration, in selected patients undergoing endovascular revascularization procedures, could lead to better results compared with a control group of patients with similar clinical background and risk factors. METHODS: We prospectively collected data of consecutive patients undergoing endovascular or hybrid revascularization in the period from June 2017 to August 2019, which were then retrospectively analyzed. Those patients were divided into 2 groups: iloprost and control groups. Inclusion criteria were as follows: the presence of an arteriography that included the foot; Rutherford class 4-6; and Rutherford class 3 with at least 2 cardiovascular risk factors or previous revascularization procedures on the same limb. The intraoperative intra-arterial administration of iloprost was the inclusion criterion for the iloprost group. Patients with a compromised cardiological condition were excluded, as this was a contraindication for iloprost administration. Patients from the 2 groups were matched using the propensity score matching (PSM) methodology of Rosenbaum and Rubin. The primary outcome was freedom from target lesion revascularization (TLR). The secondary outcomes were limb salvage and overall survival. RESULTS: During the mentioned period, we treated 190 consecutive limbs. The mean follow-up was 11.73 months (median, 10; interquartile range, 5-19). After PSM, the freedom from TLR was significantly better in the iloprost group (78 ± 7%, 74 ± 8%, and 63 ± 9% vs. 67 ± 8%, 50 ± 9%, and 38 ± 10% at 3, 6, and 12 months, respectively; P = 0.043). No significant difference was found in terms of limb salvage (92 ± 5%, 88 ± 6%, and 88 ± 6% vs. 92 ± 4%, 85 ± 6%, and 81 ± 7% at 3, 6, and 12 months, respectively; P = 0.52) and survival (95 ± 3%, 95 ± 3%, and 95 ± 3% vs. 95 ± 4%, 92 ± 5%, and 71 ± 9% at 3, 6, and 12 months, respectively; P = 0.14) between the 2 groups. CONCLUSIONS: These results seem to encourage considering intraoperative use of this adjunct, at least in endovascular revascularization procedures, to improve distal outflow.


Assuntos
Procedimentos Endovasculares , Iloprosta/administração & dosagem , Doença Arterial Periférica/terapia , Inibidores da Agregação Plaquetária/administração & dosagem , Procedimentos Cirúrgicos Vasculares , Vasodilatadores/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Iloprosta/efeitos adversos , Infusões Intra-Arteriais , Cuidados Intraoperatórios , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Inibidores da Agregação Plaquetária/efeitos adversos , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade , Vasodilatadores/efeitos adversos
9.
Molecules ; 25(5)2020 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-32120861

RESUMO

Our research groups have been involved for many years in studies aimed at identifying new active organic compounds endowed with pharmacological properties. In this work, we focused our attention on the evaluation of cardiovascular and molecular drug resistance (MDR) reverting activities of some nitrosubstituted sulphur-containing heterocycles. Firstly, we have examined the effects of 4-nitro-3-(4-methylphenyl)-3,6-dihydro-2H-thiopyran S,S-dioxide 5, and have observed no activity. Then we have extended our investigation to the 3-aryl-4-nitrobenzothiochromans S,S-dioxide 6 and 7, and have observed an interesting biological profile. Cardiovascular activities were assessed for all compounds using ex vivo studies, while the MDR reverting effect was evaluated only for selected compounds using tumor cell lines. All compounds were shown to affect cardiovascular parameters. Compound 7i exerted the most effect on negative inotropic activity, while 6d and 6f could be interesting molecules for the development of more active ABCB1 inhibitors. Both 6 and 7 represent structures of large possible biological interest, providing a scaffold for the identification of new ABCB1 inhibitors.


Assuntos
Antineoplásicos/farmacologia , Canais de Cálcio/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Cromanos/farmacologia , Resistência a Múltiplos Medicamentos/efeitos dos fármacos , Resistencia a Medicamentos Antineoplásicos/efeitos dos fármacos , Átrios do Coração/efeitos dos fármacos , Músculo Liso/efeitos dos fármacos , Subfamília B de Transportador de Cassetes de Ligação de ATP/metabolismo , Animais , Canais de Cálcio/metabolismo , Linhagem Celular Tumoral , Cromanos/síntese química , Cromanos/química , Doxorrubicina/farmacologia , Sinergismo Farmacológico , Cobaias , Átrios do Coração/metabolismo , Humanos , Concentração Inibidora 50 , Músculo Liso/fisiologia , Piranos/síntese química , Piranos/química , Compostos de Sulfidrila/síntese química , Compostos de Sulfidrila/química , Tiamina/análogos & derivados , Tiamina/síntese química , Tiamina/química , Tiamina/farmacologia
10.
Int Angiol ; 39(1): 82-88, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31814380

RESUMO

BACKGROUND: Thoracic outlet syndrome is an important clinical entity, which usually affects young patients and working cohort, causing disability if unrecognized and untreated. Although treatment is commonly conservative, in patients with more severe disease, surgical treatment is often required for decompression. Purpose of this paper was to evaluate the surgical and clinical outcomes of patients who underwent first rib resection through transaxillary approach for thoracic outlet syndrome (TOS) during a period of 30 years. METHODS: A retrospective study was conducted on a prospectively compiled, computerized database between January 1988 and December 2018 including patients affected by TOS surgically treated in two Italian centers, by the same surgeon. Patients with neurogenic and vascular TOS were included in the present analysis. The surgical approach for TOS decompression was the first rib resection using the Roos' transaxillary approach, with small variations in technique. Outcome measures considered for analysis were primary technical success, 30-day and mean follow-up re-intervention, pneumothorax, nerve injury and symptoms recurrence rates. RESULTS: One hundred three patients were treated: 89 (86.4%) women and 14 (13.6%) man; median age was 32.6±10.2 years (range 9-53). Prominent symptoms were neurogenic in 60 patients (58.2%), venous in 32 (31.1%), and arterial in 11 (7.76%) patients. In 49 patients (47.5%) with prominent neurogenic symptoms, concomitant symptoms of vascular TOS were also presents. Thirteen (12.6%) patients had cervical rib and sixteen cases (15.5%) had bilateral TOS. Technical success was achieved in all cases, and no other surgical access or secondary approach was necessary. Three patients (2.9%) presented with hand ischemia and also needed an arm vein bypass after rib resection. One (0.9%) intraoperative arterial injury was reported and nerve injury rate was 1.8%. At 30-day re-intervention rate was 0.9%: one patient experienced hemothorax solved by thoracoscopic drainage. Restrict pneumothorax was reported in 42 patients (40.8%) treated through pleural drainage. At mean follow-up of (93±9 months) partial symptoms recurrence was present in 6 patients (5.8%). CONCLUSIONS: In our experience first rib resection through the transaxillary approach is a safe and feasible procedure associated with an acceptable rate of peri-operative morbidity and satisfactory long-term relief of symptoms.


Assuntos
Descompressão Cirúrgica/métodos , Costelas/cirurgia , Síndrome do Desfiladeiro Torácico/cirurgia , Adolescente , Adulto , Criança , Angiografia por Tomografia Computadorizada , Bases de Dados Factuais , Descompressão Cirúrgica/efeitos adversos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação , Estudos Retrospectivos , Costelas/diagnóstico por imagem , Síndrome do Desfiladeiro Torácico/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
11.
Ann Vasc Surg ; 63: 443-449, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31669474

RESUMO

BACKGROUND: Treatment of severe critical limb ischemia (CLI) due to superficial femoral artery (SFA) and below-the-knee (BTK) vessels' involvement could be compromised by the lack of a great saphenous vein (GSV) suitable in its entire length. The purpose of this study is to assess the efficacy of a hybrid endovascular and open lower limbs arterial reconstruction in these patients with multilevel, advanced CLI. METHODS: From 2005 to 2019, we performed hybrid endovascular and surgical treatment for limb salvage in SFA-BTK CLI. This consisted of percutaneous transluminal angioplasty (PTA) with or without stenting of the SFA, along with distal origin vein graft bypass. Inclusion criteria were Rutherford category 5 or 6, lack of a suitable GSV, patency of the popliteal artery, steno-obstructive lesions of the SFA, lesions of the 3 crural vessels >5 cm in length each. The follow-up was performed with duplex scan surveillance of both the bypass graft and PTA sites. RESULTS: The hybrid treatment could be performed in 34 patients. Fifty-six percent of the SFA steno-obstructive lesions were treated with simple PTA, except for the application of a bare metal stent in one patient (3%), while in all the SFA occlusions PTA was completed with covered stents (41%). Thirty-four popliteal-to-distal vein bypass grafts bypass grafts have been performed. There were no perioperative PTA or bypass graft failures. Clinical improvement was achieved in 26 (76%) patients. Overall, primary and secondary patency, limb salvage, and survival rates were 65%, 68%, 75%, and 75% at 5 years, respectively. CONCLUSIONS: A hybrid strategy in multilevel SFA-BTK CLI is a well-established approach. Additional studies are warranted to validate these results.


Assuntos
Angioplastia/instrumentação , Artéria Femoral , Isquemia/terapia , Salvamento de Membro , Doença Arterial Periférica/terapia , Artéria Poplítea/cirurgia , Veia Safena/transplante , Stents , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Angioplastia/efeitos adversos , Angioplastia/mortalidade , Constrição Patológica , Estado Terminal , Bases de Dados Factuais , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Isquemia/diagnóstico por imagem , Isquemia/mortalidade , Isquemia/fisiopatologia , Salvamento de Membro/efeitos adversos , Salvamento de Membro/mortalidade , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Intervalo Livre de Progressão , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Grau de Desobstrução Vascular
12.
Molecules ; 24(21)2019 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-31683699

RESUMO

Continuing our research in the field of new heterocyclic compounds, herein we report on the synthesis and antitumor activity of new amino derivatives of pyrido[3',2':4,5](furo)thieno[3,2-d]pyrimidines as well as of two new heterocyclic systems: furo[2-e]imidazo[1,2-c]pyrimidine and furo[2,3-e]pyrimido[1,2-c]pyrimidine. Thus, by refluxing the 8-chloro derivatives of pyrido[3',2':4,5]thieno(furo)[3,2-d]pyrimidines with various amines, the relevant pyrido[3',2':4,5]thieno(furo)[3,2-d]pyrimidin-8-amines were obtained. Further, the cyclization of some amines under the action of phosphorus oxychloride led to the formation of new heterorings: imidazo[1,2-c]pyrimidine and pyrimido[1,2-c]pyrimidine. The possible antitumor activity of the newly synthesized compounds was evaluated in vitro. The biological tests evidenced that some of them showed pronounced antitumor activity. A study of the structure-activity relationships revealed that the compound activity depended mostly on the nature of the amine fragments. A docking analysis was also performed for the most active compounds.


Assuntos
Aminas/química , Aminas/síntese química , Antineoplásicos/química , Antineoplásicos/síntese química , Simulação de Acoplamento Molecular , Piridinas/química , Piridinas/síntese química , Animais , Espectroscopia de Ressonância Magnética Nuclear de Carbono-13 , Chlorocebus aethiops , Células HeLa , Humanos , Espectroscopia de Prótons por Ressonância Magnética , Termodinâmica , Células Vero
13.
J Cardiovasc Surg (Torino) ; 60(5): 582-588, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31256581

RESUMO

BACKGROUND: A geometrical understanding of the individual patient's disease morphology is crucial in aortic surgery. The aim of our study was to validate a questionnaire addressing understanding of aortic disease and use this questionnaire to investigate the value of 3D printing as a teaching tool for surgical trainees. METHODS: Anonymized CT-angiography images of six different patients were selected as didactic cases of aortic disease and made into 3D models of transparent rigid resin with the Vat-photopolymerization technique. The 3D aortic models, which could be disassembled and reassembled, were displayed to 37 surgical trainees, immediately after a seminar on aortic disease. A questionnaire was developed to compare the trainees' understanding before (T0) and after (T1) demonstration of the 3D printed models. RESULTS: A panel of 15 experts participated in evaluating face and content validity of the questionnaire. The questionnaire validity was established and therefore the information investigated by the questionnaire could be synthetized using the mean of the items to indicate the understanding. The participants (mean age 28 years, range 26-34, male 59%) showed a significant improvement in understanding from T0 (median=7.25; IQR=1.50) to T1 (median=8.00; IQR=1.50; P=0.002). CONCLUSIONS: Preliminary data suggest that the use of 3D-printed aortic models as a teaching tool was feasible and improved the understanding of aortic disease among surgical trainees.


Assuntos
Aorta/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Educação de Pós-Graduação em Medicina/métodos , Impressão Tridimensional , Cirurgiões/educação , Inquéritos e Questionários , Procedimentos Cirúrgicos Vasculares/educação , Adulto , Aorta/cirurgia , Doenças da Aorta/cirurgia , Compreensão , Escolaridade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Modelos Anatômicos , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Valor Preditivo dos Testes , Dados Preliminares , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes
14.
J Vasc Surg ; 70(6): 1904-1912.e2, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31068267

RESUMO

OBJECTIVE: The aim of our study was to identify patients' characteristics that predicted a higher chance of arteriovenous graft patency in patients undergoing Gore Hybrid Vascular Graft (GHVG; W. L. Gore & Associates, Flagstaff, Ariz) implantation for hemodialysis access. The GHVG is a polytetrafluroethylene (PTFE) prosthesis with a nitinol-reinforced section (NRS) at the venous end. METHODS: All consecutive patients undergoing GHVG implantation for hemodialysis access at 10 tertiary referral centers between December 2013 and January 2018 were included in the study and compared with a control group of patients undergoing standard PTFE graft implantation. Selection of patients for hybrid graft implantation was based on the impossibility of autogenous vascular access creation. RESULTS: There were 145 patients included in the GHVG group and 218 in the PTFE group. In the GHVG and the PTFE groups, the mean age was 67 ± 13 years and 65 ± 13 years, and male patients totaled 52% and 46%, respectively. The technical success was 99%. The mean duration of the intervention was 100 minutes (median, 95 minutes; interquartile range, 80-120 minutes). The brachial-axillary configuration was used in the majority of cases (n = 78 [54%]). The 5-cm NRS length was prevalent (n = 108 [75%]). The median NRS oversize was 14% (interquartile range, 0%-21%). Mean follow-up was 13 months (range, 0-55 months). Seventy-one patients (49%) underwent at least one reintervention. Primary, assisted primary, and secondary patency estimates at 12 months were 44% ± 5%, 47% ± 5%, and 65% ± 4% for the GHVG group and 41% ± 4%, 53% ± 4%, and 75% ± 3% for the control group, respectively (P = NS). One-year survival was 90% ± 3%. On multivariable Cox regression analysis, hypotension (P < .001; hazard ratio [HR], 5.8; confidence interval [CI], 2.6-13) and diabetes (P = .024; HR, 1.9; CI, 1.1-3.2) were significant predictors of GHVG loss. A larger graft size was protective against GHVG loss (P = .042; HR, 0.73; CI, 0.54-0.99). The 10-cm-long graft showed a tendency toward improved patency but did not reach statistical significance (P = .074; HR, 0.48; CI, 0.21-1.07). CONCLUSIONS: Diabetes and hypotension were predictors of loss of hybrid arteriovenous access. Smaller diameters of NRS were more prone to thrombosis, whereas the 10-cm length seemed to perform better than the 5-cm one.


Assuntos
Derivação Arteriovenosa Cirúrgica , Prótese Vascular , Sistema de Registros , Diálise Renal , Dispositivos de Acesso Vascular , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Politetrafluoretileno , Desenho de Prótese , Estudos Retrospectivos , Estados Unidos , Grau de Desobstrução Vascular , Adulto Jovem
15.
J Thorac Cardiovasc Surg ; 157(2): 467-476.e1, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30121136

RESUMO

OBJECTIVE: Four-dimensional flow cardiovascular magnetic resonance may improve assessment of hemodynamics in patients with aortic dissection. The purpose of this study was to evaluate the feasibility and accuracy of 4-dimensional flow cardiovascular magnetic resonance assessment of true and false lumens flow. METHODS: Thirteen ex vivo porcine aortic dissection models were mounted to a flow loop. Four-dimensional flow cardiovascular magnetic resonance and 2-dimensional phase-contrast cardiovascular magnetic resonance measurements were performed, assessed for intraobserver and interobserver variability, and compared with a reference standard of sonotransducer flow volume measurements. Intraobserver and interobserver variability of 4-dimensional flow cardiovascular magnetic resonance were also assessed in 14 patients with aortic dissection and compared with 2-dimensional phase-contrast cardiovascular magnetic resonance. RESULTS: In the ex vivo model, the intraobserver and interobserver measurements had Lin's correlation coefficients of 0.98 and 0.96 and mean differences of 0.17 (±3.65) mL/beat and -0.59 (±5.33) mL/beat, respectively; 4-dimensional and sonotransducer measurements had a Lin's concordance correlation coefficient of 0.95 with a mean difference of 0.35 (±4.92) mL/beat, respectively. In patients with aortic dissection, the intraobserver and interobserver measurements had Lin's concordance correlation coefficients of 0.98 and 0.97 and mean differences of -0.95 (±8.24) mL/beat and 0.62 (±10.05) mL/beat, respectively; 4-dimensional and 2-dimensional flow had a Lin's concordance correlation coefficient of 0.91 with a mean difference of -9.27 (±17.79) mL/beat because of consistently higher flow measured with 4-dimensional flow cardiovascular magnetic resonance in the ascending aorta. CONCLUSIONS: Four-dimensional flow cardiovascular magnetic resonance is feasible in patients with aortic dissection and can reliably assess flow in the true and false lumens of the aorta. This promotes potential future work on functional assessment of aortic dissection hemodynamics.


Assuntos
Aorta/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Idoso , Dissecção Aórtica/fisiopatologia , Animais , Aorta/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Suínos
16.
Ann Vasc Surg ; 56: 254-260, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30339903

RESUMO

BACKGROUND: The aim of this study is to retrospectively analyze the early and long-term outcomes of endovascular treatment of Trans-Atlantic Inter-Society Consensus II class C and D (TASC II) aortoiliac occlusive disease with an expanded polytetrafluoroethylene-covered stent graft. METHODS: Between January 2006 and November 2017, 61 patients (53 males, 8 females), with symptomatic aortoiliac stenotic and/or occlusive disease, were treated with VIABAHN (W.L. Gore and Associates, Flagstaff, Ariz) at 2 University medical centers. The morphology of the lesions was evaluated and classified by contrast-enhanced computed tomography angiography. Demographic data, operation details, and postoperative outcomes were collected. Follow-up data were analyzed by a life-table analysis (Kaplan-Meier test). RESULTS: Mean age of the patients was 64.89 ± 10.77 years (range 44-89). Thirty-seven patients (60.7%) presented with severe claudication (Rutherford 3), whereas 21 (34.4%) were in Rutherford class 4 and the remaining 3 patients (4.9%) suffered from necrotic lesions (Rutherford 5/6). Fifty-six patients were smokers (91.8%), 38 (62.3%) had hypertension, 23 (37.7%) had coronary artery disease, 30 (40.2%) had dyslipidemia, 18 (29.5%) had chronic obstructive pulmonary disease, 6 (9.5%) had renal insufficiency (serum creatinine>2.0 mg/dL) and 24 (39.3%) had diabetes. Technical success was achieved in 59/61 patients (96.7%) with 16 patients (26.2%) requiring combined percutaneous brachial access to obtain iliac recanalization. Perioperative mortality was 1.6%, whereas postoperative major complications occurred in 2 patients (3.6%). The mean number of VIABAHN placed was 1.77/patient. Mean follow-up was 31.5 months (range 1-108) and primary patency at 36 months was 94.9%. Two major amputations of the lower limbs occurred during the follow-up. CONCLUSIONS: Open surgery with the aortobifemoral bypass has been the gold standard treatment for complex aortoiliac occlusive disease although complications and mortality still remain significant issues. Our results suggest that endovascular therapy of TASC C and D iliac lesions using the VIABAHN stent graft is feasible, effective, and has good, long-term patency.


Assuntos
Doenças da Aorta/cirurgia , Arteriopatias Oclusivas/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Artéria Ilíaca/cirurgia , Politetrafluoretileno , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Aortografia/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Itália , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
17.
J Vasc Surg ; 68(6): 1925-1935.e8, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30115384

RESUMO

OBJECTIVES: Acute type B aortic dissection can have a stable course or evolve into aneurysm and subsequent adverse events. The aim of this systematic review was to analyze the morphologic predictors of an adverse course to establish their validity based on consistency of results. METHODS: Fifty-one studies were included in this review, reporting on aortic size, false lumen (FL) size, primary entry tear (ET) size and location, status of FL thrombosis, number of ETs, branch vessels involvement, and FL longitudinal extent. RESULTS: Some predictors showed good consistency, whereas others did not. Aortic size was the most investigated predictor. A larger diameter at presentation predicted worse outcomes, with few exceptions. Both FL size and size relative to true lumen size also predicted an adverse course, although a standardized measurement method was not used. Regarding primary ET size and location, evidence was sparse and somewhat conflicting. Although FL complete thrombosis was consistently associated with a more benign course, the role of partial thrombosis remained unclear and the concept of FL saccular formation might account for the inconsistency, but further evidence is needed. A higher number of re-entry tears was considered to be protective against false channel expansion, but results need to be confirmed. The predictive role of branch vessels involvement and FL longitudinal extent remain controversial. CONCLUSIONS: Among several predictors of aortic growth and events in acute type B aortic dissection, controversial and even conflicting results have been described. Consistent evidence has been demonstrated only for two predictors: aortic size at presentation is associated with adverse events and total FL thrombosis has a protective role.


Assuntos
Aorta/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Doença Aguda , Dissecção Aórtica/patologia , Aorta/patologia , Aneurisma Aórtico/patologia , Dilatação Patológica , Progressão da Doença , Humanos , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Trombose/diagnóstico por imagem
18.
Ann Vasc Surg ; 39: 293.e1-293.e5, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27908807

RESUMO

BACKGROUND: To report a technical complication during a chimney-thoracic endovascular aneurysm repair (Ch-TEVAR) procedure. METHODS: A 77-year-old female patient underwent Ch-TEVAR for a symptomatic thoracic aortic aneurysm with a short and angulated proximal neck. Deployment of the aortic stent graft over the left subclavian artery (LSA) was followed by placement of a balloon-expandable covered stent as a chimney for the LSA. RESULTS: Chimney deployment failed due to balloon perforation. Additional attempts with several balloons all failed, albeit gaining some additional expansion of the chimney stent graft. The technical complication was solved by deploying a self-expanding bare stent inside the chimney stent. This enabled additional ballooning and further expansion of the chimney stent graft leading to an acceptable end result. CONCLUSIONS: Ch-TEVAR with a balloon-expandable chimney stent graft can be complicated by incomplete chimney deployment due to balloon perforation. Relining of the chimney stent graft with a self-expanding stent improved the deployment with acceptable patency.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Falha de Prótese , Stents , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Desenho de Prótese , Resultado do Tratamento
19.
J Vasc Surg ; 65(1): 142-150, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27743809

RESUMO

OBJECTIVE: The purpose of this study was to examine the outcomes of a vascular hybrid polytetrafluoroethylene (PTFE) graft, provided with a nitinol-reinforced section (NRS) on one end, in hemodialysis vascular access placement. METHODS: A retrospective study was conducted including all the consecutive patients who underwent Gore Hybrid Vascular Graft (GHVG; W. L. Gore & Associates, Flagstaff, Ariz) implantation for hemodialysis access placement between October 2013 and November 2015. A propensity-matched control group was obtained from consecutive patients who underwent standard PTFE arteriovenous graft implantation between January 2010 and July 2013. The selection criteria were inadequate venous material for autogenous arteriovenous fistula placement, patent deep venous circulation, and vein diameter of 4 to 8.5 mm. The implantation technique involves the insertion of the NRS some centimeters into the target vein. Fluoroscopic guidance helps deploy the device in the desired landing zone (ie, position of the proximal end of the NRS), based on anatomic landmarks. Survival, functional patency rates, and complications were compared with a propensity-matched historical control group. Vein diameter, previous vascular access placement, and diabetes were tested as predictors of reintervention with a logistic regression analysis. RESULTS: There were 32 patients (14 men; mean age, 69 ± 14 years) who received the GHVG graft. The historical control group included 43 patients. Technical success was 100%. The graft configuration was brachial-axillary (n = 22 [69%]), brachial-basilic loop (n = 5 [16%]), brachial-antecubital loop (n = 3 [9%]), axilloaxillary loop (n = 1 [3%]), and femoral-femoral loop (n = 1 [3%]). Mean NRS oversize was 20% ± 7% (range, 3%-34%; median, 19%). Perioperative complications requiring revision included acute limb ischemia treated with thrombectomy (n = 1 [3%]) and graft infection requiring explantation (n = 2 [6%]). Two patients (6%) died in the hospital of unrelated causes. The mean follow-up was 15 ± 11 months (range, 0-33 months; median, 15.5). The propensity-matched groups included 25 patients each. Survival estimates at 24 months for the GHVG and standard PTFE groups were 91% ± 6% and 82% ± 9% (P > .05), respectively. The 12-month patency estimates were as follows: functional primary patency, 66% ± 10% vs 51% ± 10% (P > .05); functional assisted primary patency, 75% ± 9% vs 51% ± 10% (P > .05); and functional secondary patency, 79% ± 9% vs 67% ± 10% (P > .05). Reduction in vein diameter was associated with reintervention. CONCLUSIONS: The GHVG is a safe and effective alternative to standard PTFE in hemodialysis access surgery. Careful planning for the landing zone is advisable, especially for small outflow veins. Larger studies and randomized trials are needed to define the role for this device. A study including a greater number of centers experienced with this device is currently under way.


Assuntos
Ligas , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Politetrafluoretileno , Diálise Renal , Veias/cirurgia , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/efeitos adversos , Distribuição de Qui-Quadrado , Feminino , Humanos , Itália , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Flebografia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Pontuação de Propensão , Modelos de Riscos Proporcionais , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Veias/diagnóstico por imagem , Veias/fisiopatologia
20.
Ann Vasc Surg ; 40: 136-145, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27671455

RESUMO

BACKGROUND: The aim of the study was to evaluate the diagnostic effectiveness of color Doppler ultrasound (CDUS) with superb microvascular imaging (SMI) compared to contrast-enhanced ultrasound (CEUS), computed tomography (CT) multislice angiography (64 slices), and angiography required for therapeutic reasons, for follow-up after endovascular aneurysm repair (EVAR). METHODS: From March 2014 to May 2015, 57 patients treated with EVAR were evaluated with CT, CEUS, CDUS, SMI, and angiography in cases requiring treatment. Evaluation included sac diameter, stent-graft integrity, identification, and classification of endoleaks. Sensitivity, specificity, accuracy, and negative and positive predictive values were evaluated for each modality of endoleak identification. RESULTS: Eight endoleaks (16.3%), all type II, were documented. Sensitivity of CT, CEUS, CDUS and SMI was 88%, 100%, 63%, and 75%, respectively. Specificity of CT, CEUS, CDUS, and SMI was 100%, 100%, 96%, and 98%, respectively With SMI, CDUS sensitivity significantly increased, whereas specificity did not register great differences. CONCLUSIONS: SMI was more accurate than CDUS but less accurate than CEUS and CT to identify endoleaks after EVAR. SMI could be concretely used in the follow-up phase to increase CDUS accuracy especially in patients who cannot be studied with CEUS or CT.


Assuntos
Aneurisma Aórtico/cirurgia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Microvasos/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Ultrassonografia Doppler em Cores , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Aneurisma Aórtico/diagnóstico por imagem , Implante de Prótese Vascular/instrumentação , Endoleak/etiologia , Endoleak/fisiopatologia , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Microcirculação , Microvasos/fisiopatologia , Valor Preditivo dos Testes , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA