Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Lancet ; 403(10436): 1543-1553, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38604209

RESUMO

BACKGROUND: The coronary sinus reducer (CSR) is proposed to reduce angina in patients with stable coronary artery disease by improving myocardial perfusion. We aimed to measure its efficacy, compared with placebo, on myocardial ischaemia reduction and symptom improvement. METHODS: ORBITA-COSMIC was a double-blind, randomised, placebo-controlled trial conducted at six UK hospitals. Patients aged 18 years or older with angina, stable coronary artery disease, ischaemia, and no further options for treatment were eligible. All patients completed a quantitative adenosine-stress perfusion cardiac magnetic resonance scan, symptom and quality-of-life questionnaires, and a treadmill exercise test before entering a 2-week symptom assessment phase, in which patients reported their angina symptoms using a smartphone application (ORBITA-app). Patients were randomly assigned (1:1) to receive either CSR or placebo. Both participants and investigators were masked to study assignment. After the CSR implantation or placebo procedure, patients entered a 6-month blinded follow-up phase in which they reported their daily symptoms in the ORBITA-app. At 6 months, all assessments were repeated. The primary outcome was myocardial blood flow in segments designated ischaemic at enrolment during the adenosine-stress perfusion cardiac magnetic resonance scan. The primary symptom outcome was the number of daily angina episodes. Analysis was done by intention-to-treat and followed Bayesian methodology. The study is registered with ClinicalTrials.gov, NCT04892537, and completed. FINDINGS: Between May 26, 2021, and June 28, 2023, 61 patients were enrolled, of whom 51 (44 [86%] male; seven [14%] female) were randomly assigned to either the CSR group (n=25) or the placebo group (n=26). Of these, 50 patients were included in the intention-to-treat analysis (24 in the CSR group and 26 in the placebo group). 454 (57%) of 800 imaged cardiac segments were ischaemic at enrolment, with a median stress myocardial blood flow of 1·08 mL/min per g (IQR 0·77-1·41). Myocardial blood flow in ischaemic segments did not improve with CSR compared with placebo (difference 0·06 mL/min per g [95% CrI -0·09 to 0·20]; Pr(Benefit)=78·8%). The number of daily angina episodes was reduced with CSR compared with placebo (OR 1·40 [95% CrI 1·08 to 1·83]; Pr(Benefit)=99·4%). There were two CSR embolisation events in the CSR group, and no acute coronary syndrome events or deaths in either group. INTERPRETATION: ORBITA-COSMIC found no evidence that the CSR improved transmural myocardial perfusion, but the CSR did improve angina compared with placebo. These findings provide evidence for the use of CSR as a further antianginal option for patients with stable coronary artery disease. FUNDING: Medical Research Council, Imperial College Healthcare Charity, National Institute for Health and Care Research Imperial Biomedical Research Centre, St Mary's Coronary Flow Trust, British Heart Foundation.


Assuntos
Angina Estável , Doença da Artéria Coronariana , Seio Coronário , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/terapia , Angina Estável/tratamento farmacológico , Seio Coronário/diagnóstico por imagem , Teorema de Bayes , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Método Duplo-Cego , Isquemia , Adenosina
2.
Am Heart J ; 257: 20-29, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36410442

RESUMO

BACKGROUND: Patients with prior coronary artery bypass grafting (CABG) frequently require repeat percutaneous revascularization due to advanced age, progressive coronary artery disease and bypass graft failure. Percutaneous coronary intervention (PCI) of either the bypass graft or the native coronary artery may be performed. Randomized trials comparing native vessel PCI with bypass graft PCI are lacking and long-term outcomes have not been reported. METHODS: PROCTOR (NCT03805048) is a prospective, multicenter, randomized controlled trial, that will include 584 patients presenting with saphenous vein graft (SVG) failure and a clinical indication for revascularization, as determined by the local Heart Team. The trial is designed to compare the clinical and angiographic outcomes in patients randomly allocated in a 1:1 fashion to either a strategy of native vessel PCI or SVG PCI. The primary study endpoint is a 3-year composite of major adverse cardiac events (MACE: all-cause mortality, non-fatal target coronary territory myocardial infarction [MI], or clinically driven target coronary territory revascularization). At 3-years, after evaluation of the primary endpoint, follow-up invasive coronary angiography will be performed. Secondary endpoints comprise individual components of MACE at 1, 3 and 5 years follow-up, PCI-related MI, MI >48 hours after index PCI, target vessel failure, target lesion revascularization, renal failure requiring renal-replacement therapy, angiographic outcomes at 3-years and quality of life (delta Seattle Angina Questionnaire, Canadian Cardiovascular Society Grading Scale and Rose Dyspnea Scale). CONCLUSION: PROCTOR is the first randomized trial comparing an invasive strategy of native coronary artery PCI with SVG PCI in post-CABG patients presenting with SVG failure.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Estudos Prospectivos , Intervenção Coronária Percutânea/efeitos adversos , Veia Safena/transplante , Qualidade de Vida , Resultado do Tratamento , Stents Farmacológicos/efeitos adversos , Canadá , Ponte de Artéria Coronária/efeitos adversos , Infarto do Miocárdio/etiologia
3.
Int J Cardiol ; 375: 14-20, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36565956

RESUMO

BACKGROUND: Chronic total occlusion (CTO) percutaneous coronary intervention (PCI) is associated with a considerable risk of complications, and risk stratification is of utmost importance. AIMS: To assess the clinical usefulness of the recently developed PROGRESS-CTO (NCT02061436) complication risk scores in an independent cohort. METHODS: Individual patient data pooled analysis of 3 registries was performed. RESULTS: Of the 4569 patients who underwent CTO PCI, 102 (2.2%) had major adverse cardiovascular events (MACE). Patients with MACE were older (69 ± 11 vs. 65 ± 10, p < 0.001), more likely to have a history of prior coronary artery bypass graft surgery, and unfavorable angiographic characteristics J-CTO score (2.4 ± 1.2 vs. 2.1 ± 1.3, p = 0.007), including blunt stump (59% vs. 49%, p = 0.047). Technical success was lower in patients with MACE (59% vs. 86%, p < 0.001). The area under the receiver operating characteristic curve of the PROGRESS-CTO complication risk models were as follows: MACE 0.72 (95% confidence interval [CI], 0.67-0.76), mortality 0.73 (95% CI, 0.61-0.85), and pericardiocentesis 0.69 (95% CI, 0.62-0.77) in the validation dataset. The observed complication rates increased with higher PROGRESS-CTO complication scores. The PROGRESS-CTO MACE score showed good calibration in this external cohort, with MACE rates similar to the original study: 0.7% (score 0-1), 1.5% (score 2), 2.2% (score 3), 3.8% (score 4), 4.9% (score 5), 5.8% (score 6-7). CONCLUSION: Given the good discriminative performance, calibration, and ease of calculation, the PROGRESS-CTO complication scores could help assess the risk of complications in patients undergoing CTO PCI.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Angiografia Coronária/efeitos adversos , Fatores de Risco , Sistema de Registros , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Doença Crônica
4.
JACC Cardiovasc Interv ; 14(12): 1308-1319, 2021 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-34052151

RESUMO

OBJECTIVES: The authors sought to examine the outcomes of percutaneous coronary intervention (PCI) for in-stent restenosis (ISR) chronic total occlusions (CTOs). BACKGROUND: The outcomes of PCI for ISR CTOs have received limited study. METHODS: The authors examined the clinical and angiographic characteristics and procedural outcomes of 11,961 CTO PCIs performed in 11,728 patients at 107 centers in Europe, North America, Latin America, and Asia between 2012 and 2020, pooling patient-level data from 4 multicenter registries. In-hospital major adverse cardiovascular events (MACE) included death, myocardial infarction, stroke, and tamponade. Long-term MACE were defined as the composite of all-cause death, myocardial infarction, and target vessel revascularization. RESULTS: ISR represented 15% of the CTOs (n = 1,755). Patients with ISR CTOs had higher prevalence of diabetes (44% vs. 38%; p < 0.0001) and prior coronary artery bypass graft surgery (27% vs. 24%; p = 0.03). Mean J-CTO (Multicenter CTO Registry in Japan) score was 2.32 ± 1.27 in the ISR group and 2.22 ± 1.27 in the de novo group (p = 0.01). Technical (85% vs. 85%; p = 0.75) and procedural (84% vs. 84%; p = 0.82) success was similar for ISR and de novo CTOs, as was the incidence of in-hospital MACE (1.7% vs. 2.2%; p = 0.25). Antegrade wiring was the most common successful strategy, in 70% of ISR and 60% of de novo CTOs, followed by retrograde crossing (16% vs. 23%) and antegrade dissection and re-entry (15% vs. 16%; p < 0.0001). At 12 months, patients with ISR CTOs had a higher incidence of MACE (hazard ratio: 1.31; 95% confidence interval: 1.01 to 1.70; p = 0.04). CONCLUSIONS: ISR CTOs represent 15% of all CTO PCIs and can be recanalized with similar success and in-hospital MACE as de novo CTOs.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/epidemiologia , Oclusão Coronária/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
5.
J Invasive Cardiol ; 33(3): E146-E154, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33570501

RESUMO

AIMS: Radiation exposure is a limiting factor for percutaneous coronary interventions (PCI) of chronic total coronary occlusion (CTO) lesions. This study was designed to analyze changes in patient radiation dose for CTO-PCI and parameters associated with radiation dose. METHODS AND RESULTS: We analyzed a cohort of 12,136 procedures performed by 23 operators between 2012 and 2017 from the European Registry of CTO-PCI. Radiation exposure was recorded as air kerma (AK) and dose area product (DAP). A dose rate index (DRI) was calculated as AK per fluoroscopy time to normalize for individual differences in fluoroscopy time. The lesion complexity increased from Japanese-CTO (J-CTO) score of 2.19 ± 1.44 to 2.46 ± 1.28, with an increase of retrograde procedures from 31.1% to 40.7%; still, procedural success improved from 87.7% to 92.1%. Fluoroscopy time remained similar, but AK decreased by 14.9%, from 2.35 Gy (interquartile range [IQR], 1.29-4.14 Gy) to 2.00 Gy (IQR, 1.08-3.45 Gy) and DAP decreased by 21.5%, from 130 Gy•cm² (IQR, 70-241 Gy•cm²) to 102 Gy•cm² (IQR, 58-184 Gy•cm²). Radiation exposure was determined by the lesion complexity (J-CTO score) and procedural complexity (antegrade or retrograde). DRI was determined by fluoroscopy frame rate and type of equipment used, but the major influence remained interoperator differences. CONCLUSIONS: Radiation exposure decreased during the observation period despite an increase in lesion and procedural complexity. While many operators already achieved a goal of low radiation exposure, there were considerable interoperator differences in radiation management, indicating further potential for improvement.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Exposição à Radiação , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico , Oclusão Coronária/cirurgia , Fluoroscopia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 97(1): E51-E60, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32369681

RESUMO

AIM: Chronic total occlusions (CTO) in patients with history of coronary artery bypass graft (CABG) show more advanced and complex atherosclerotic pathology. Aim of our study is to compare outcomes in patients undergoing CTO percutaneous coronary intervention (PCI) with previous CABG versus those without in the REgistry of Crossboss and Hybrid procedures in FrAnce the NetheRlands, BelGium and UnitEd Kingdom (RECHARGE). METHODS & RESULTS: The RECHARGE cohort (1,252 patients) was divided in two groups according to the presence of previous CABG (217) or not. We also focused, in the post-CABG group, on a comparison between CTO in previously grafted vessels versus non-grafted vessels. The CTO complexity scores were higher and the success rate (71.9% vs. 88.7%, p < .001) was lower in the CABG group, this difference was driven by higher failure rates in high-complexity-score CTO. The rate of in-hospital complications was similar. In the post-CABG group, the procedural success of CTO located in previously grafted vessels versus those in vessels not previously grafted, was comparably suboptimal (73.1% vs. 68%, p = .47). CONCLUSION: Patients undergoing CTO PCI with prior CABG have a higher prevalence of comorbidities and more complex lesion characteristics. In the post-CABG population the success rate was significantly lower, particularly in high CTO complexity scores, though complication rates were comparable. In the post-CABG population, the CTO success rate was independent of the presence of a previous graft on the CTO vessel.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Bélgica/epidemiologia , Doença Crônica , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Humanos , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Fatores de Risco , Resultado do Tratamento , Reino Unido/epidemiologia
7.
Coron Artery Dis ; 31(7): 573-577, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32868660

RESUMO

BACKGROUND: The aim of this study was to evaluate the safety and efficacy of the novel NovaCross microcatheter system in patients with ischemic heart disease due to coronary chronic total occlusions (CTO). METHODS: A total of 191 subjects between the ages of 25-80 years were recruited in 10 investigational sites. Each subject underwent a percutaneous coronary intervention (PCI) of a CTO lesion using the NovaCross microcatheter, equipped with expandable nitinol scaffolds to enhance guidewire penetration and crossing of the CTO lesion. The primary safety endpoint was procedural major adverse cardiac events [composite of death, myocardial infarction (MI), or urgent target vessel revascularization]. The primary efficacy endpoint was to assess the ability of the NovaCross microcatheter to successfully facilitate the placement of a guidewire beyond a native coronary CTO in the true vessel lumen. After the PCI, subjects remained in hospital until a 12-lead ECG and blood tests for cardiac biomarkers were taken at 3-6 h and 8-16 h post-procedure. RESULTS: No deaths, urgent revascularization, or urgent coronary artery bypass surgery were reported. The reported MI rate according to the protocol definition was 12.3%, and technical success was achieved in 75.3% of the subjects regardless of CTO procedure technique. In 89.2% of the subjects, the NovaCross succeeded in penetrating the proximal CTO cap, and in 25.8% of the subjects, the extendable portion of the NovaCross crossed the full length of the CTO lesion. CONCLUSIONS: The NovaCross met both the primary safety endpoint and the primary efficacy endpoint. We, therefore, conclude that the device is well tolerated, effective, and could be easily adopted by interventional cardiologists.


Assuntos
Ligas/farmacologia , Cateteres Cardíacos , Oclusão Coronária/cirurgia , Vasos Coronários , Intervenção Coronária Percutânea , Materiais Biocompatíveis/farmacologia , Cateteres Cardíacos/efeitos adversos , Cateteres Cardíacos/normas , Angiografia Coronária/métodos , Oclusão Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Desenho de Equipamento , Feminino , Humanos , Masculino , Teste de Materiais/métodos , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/prevenção & controle , Avaliação de Resultados em Cuidados de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Stents , Alicerces Teciduais
9.
Cardiovasc Revasc Med ; 20(12): 1048-1052, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30745059

RESUMO

BACKGROUND: Competitive flow from saphenous vein grafts (SVG) that remain patent following percutaneous coronary intervention (PCI) of the native vessel may compromise durability of the reconstructed vessel. SVG sacrifice has been advocated, but the safety and longer-term outcomes of this are unknown. METHODS: We retrospectively reviewed all post-bypass patients who following successful PCI of the native vessel underwent attempted saphenous vein graft (SVG) closure between January 2014 and July 2018 in two institutions. The co-primary end-points of interest were safety and target lesion failure (TLF), defined as a composite of cardiac death, target vessel recurrent myocardial infarction or clinically driven target lesion revascularisation (TLR). RESULTS: Of the 33 consecutive patients included, the reconstructed native vessel was a chronic total occlusion (CTO) in 93.9% of patients (n = 31) with a mean J-CTO score of 3.2 (±1.1) SVG closure was successful in 97.0% of patients (n = 32). Amplatzer Vascular Plugs (AVP; Abbott Vascular) were used in all patients with most grafts closed by a single plug (72.7%). The average procedure time was 20.1 min with evidence of a short learning curve. Over a mean follow up of 602 (±393) days from the date of SVG closure, the incidence of TLF was 9.1% (n = 3). There was an additional case of targe vessel failure (TVF) due to progression of native vessel disease not treated at the index procedure. SVG closure resulted in only 1 episode of "slow flow" that was transient and self-resolving. There were no other associated peri-procedural or in-hospital complications. CONCLUSION: Following native vessel PCI, SVG sacrifice may be considered to terminate the potentially deleterious effects of residual competitive flow. In selected cases, this approach achieves high success rate and favourable longer-term outcomes.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/terapia , Oclusão Coronária/terapia , Intervenção Coronária Percutânea , Veia Safena/transplante , Idoso , Doença Crônica , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Oclusão Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Retrospectivos , Fatores de Risco , Veia Safena/diagnóstico por imagem , Veia Safena/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Reino Unido , Grau de Desobstrução Vascular
10.
Catheter Cardiovasc Interv ; 92(3): E254-E261, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29411518

RESUMO

OBJECTIVES: A retrospective study was performed to investigate if the generation of X-ray system used was an independent factor for radiation dose in chronic total occlusion (CTO) percutaneous coronary intervention (PCI). BACKGROUND: PCI procedures for CTOs are known to be associated with higher doses of radiation. The authors suspected progressive reductions in radiation doses for CTO PCI as newer X-ray systems were introduced into clinical practice. METHODS: Procedures performed over a five-year period by three interventional cardiologists were retrospectively reviewed. Five different X-ray systems were used across three hospital sites. These included: Axiom Artis and Coroskop HIP (both Siemens), Innova (GE), Allura Xper FD 10, and Allura Clarity FD 10 (both Philips). Procedural and demographic data including body mass index (BMI; kg/m2 ), fluoroscopy time (min), and dose area product (DAP; cGycm2 ) were collated for each procedure. Statistical analysis was performed to compare the influence each X-ray system would have on DAP values after BMI and fluoroscopy time were controlled for. RESULTS: In total, 860 procedures were analyzed. Mean fluoroscopy time was 40.00 ± 19.99 min, mean BMI was 29.90 ± 5.13 kg/m2 , mean DAP 11,980 ± 7,947 cGycm2 . Log values of DAP were used to normalize results in a general linear model. A significant statistical difference in DAP between X-ray systems was demonstrated after fluoroscopy time and BMI were controlled for (P ≤ 0.001). CONCLUSION: There is a significant impact on DAP values resulting from the generation of X-ray system used, measured during PCI for CTOs, with the most modern systems producing the lowest radiation doses.


Assuntos
Cateterismo Cardíaco/instrumentação , Angiografia Coronária/instrumentação , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea/instrumentação , Doses de Radiação , Exposição à Radiação , Radiografia Intervencionista/instrumentação , Cateterismo Cardíaco/efeitos adversos , Doença Crônica , Angiografia Coronária/efeitos adversos , Desenho de Equipamento , Humanos , Irlanda do Norte , Intervenção Coronária Percutânea/efeitos adversos , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Escócia , Fatores de Tempo , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 91(2): 175-179, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29193753

RESUMO

OBJECTIVES: The aim of the Hybrid Video Registry (HVR) is to assess the acute safety and efficacy of the Hybrid Approach in comparison to other contemporary methods of CTO-PCI. BACKGROUND: Recently, multiple techniques in Percutaneous Coronary Intervention (PCI) for coronary Chronic Total Occlusions (CTO) have been synthesized into a method referred to as the "Hybrid Approach". METHODS: About 194 video-taped timed live cases from CTO-PCI training workshops were analyzed by independent data abstractors and compared to three contemporary CTO-PCI registries stratified by case complexity based on the J-CTO score. RESULTS: Overall procedural success was 95% of all cases attempted with an excellent safety profile. In the most complex lesion subset, which made up 45% of all HVR cases, success was 92.8%, which was significantly higher than either the Royal Bromptom (78.9%), or Japanese-CTO (73.3%) registries, P = 0.04 Hybrid vs. Royal Brompton, P = 0.006 Hybrid vs. Japanese-CTO). The Hybrid Approach was also associated with shorter procedure times and lower contrast utilization. CONCLUSIONS: In a real world angiographic registry of complex CTOs, the Hybrid Approach to CTO-PCI is safe, and may be superior to other contemporary approaches to CTO intervention with respect to procedural success and efficiency among a diverse group of operators and lesion complexity. © 2017 Wiley Periodicals, Inc.


Assuntos
Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea/métodos , Gravação em Vídeo , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Humanos , Japão , Duração da Cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias/etiologia , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Reino Unido , Estados Unidos
12.
Circ Cardiovasc Interv ; 10(9)2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28851720

RESUMO

BACKGROUND: Small observational studies demonstrate the feasibility of transradial approach for chronic total occlusion (CTO) percutaneous coronary intervention. The aim of the current study is to assess technical success, complication rates, and procedural efficiency in fully transradial approach (fTRA) and transfemoral approach (TFA) in a large prospective European registry adopting the hybrid algorithm for CTO percutaneous coronary intervention (Registry of CrossBoss and Hybrid Procedures in France, the Netherlands, Belgium and United Kingdom, RECHARGE registry). METHODS AND RESULTS: We analyzed 1253 CTO percutaneous coronary intervention procedures performed according to the hybrid protocol in 17 European centers, comparing fTRA (single or biradial access) and TFA (single or bifemoral or combined radial and femoral access). fTRA was applied in 306 (24%) and TFA in 947 (76%) cases. The average Japanese CTO score was 2.1±1.2 in fTRA and 2.3±1.1 in TFA (P=0.06). Technical success was achieved in 85% in fTRA and 86% in TFA (P=0.51). Technical success was comparable for fTRA and TFA in different Japanese CTO score subgroups after multivariable analysis and after propensity adjustment. In-hospital major adverse cardiac and cerebral events occurred in 2.0% in fTRA and 2.9% in TFA (P=0.40). Major access site bleeding occurred in 0.3% in fTRA and 0.5% in TFA (P=0.66). fTRA compared with TFA had similar procedural duration (80 minutes [54-120 minutes] versus 90 minutes [60-121 minutes]; P=0.07), similar radiation dose (dose area product 89 Gray×cm2 [52-163 Gray×cm2] versus 101 Gray×cm2 [59-171 Gray×cm2]; P=0.06), and lower contrast agent use (200 mL [150-310 mL] versus 250 mL [200-350 mL]; P<0.01). CONCLUSIONS: fTRA CTO percutaneous coronary intervention is a valid alternative to TFA with a high rate of success, low complication rates, and no decrease in procedural efficiency.


Assuntos
Algoritmos , Cateterismo Periférico/métodos , Oclusão Coronária/cirurgia , Técnicas de Apoio para a Decisão , Artéria Femoral , Intervenção Coronária Percutânea/métodos , Artéria Radial , Idoso , Cateterismo Periférico/efeitos adversos , Distribuição de Qui-Quadrado , Doença Crônica , Tomada de Decisão Clínica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Europa (Continente) , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Pontuação de Propensão , Estudos Prospectivos , Artéria Radial/diagnóstico por imagem , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
J Am Coll Cardiol ; 68(18): 1958-1970, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27788851

RESUMO

BACKGROUND: The hybrid algorithm for chronic total occlusion (CTO) percutaneous coronary intervention (PCI) was developed to improve procedural outcomes. Large, prospective studies validating the algorithm in a broad multicenter setting with operators of different experience levels are lacking. OBJECTIVES: The RECHARGE (REgistry of Crossboss and Hybrid procedures in FrAnce, the NetheRlands, BelGium and UnitEd Kingdom) registry aims to report achievable results using the hybrid algorithm. METHODS: Between January 2014 and October 2015, consecutive patients undergoing hybrid CTO-PCI were prospectively enrolled in 17 centers. Procedural techniques, outcomes, and in-hospital complications were analyzed. RESULTS: A total of 1,253 CTO-PCIs were performed in 1,177 patients, of which 86% were men. Mean age was 66 ± 11 years. The average Japanese CTO score was 2.0 ± 1.0, and was higher in the failure group (2.6 ± 0.6 vs. 1.9 ± 1.0; p < 0.001). Overall procedure success was 86% and major in-hospital complications occurred in 2.6%. Antegrade wire escalation was the preferred primary strategy in 77%, followed by retrograde (17%) and antegrade dissection re-entry strategies (7%). Primary strategies were successful in 60%. Consecutive strategies were applied in 34% and were successful in 74%. Antegrade dissection re-entry and retrograde strategies were the most common bailout strategies and were successful in 67% and 62%, respectively. Median procedure and fluoroscopy time were 90 (interquartile range [IQR]: 60 to 120) min and 35 (IQR: 21 to 55) min, contrast volume was 250 (IQR: 180 to 340) ml, and radiation doses (air kerma and dose area product) were 1.6 (IQR: 1.0 to 2.7) Gy and 98 (IQR: 57 to 168) Gy·cm2, respectively. CONCLUSIONS: High procedure and patient success rates, combined with a low event rate and improved procedural characteristics, support further use of the hybrid algorithm for a broad community of appropriately trained CTO operators.


Assuntos
Algoritmos , Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea/métodos , Idoso , Europa (Continente) , Feminino , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros
15.
J Invasive Cardiol ; 27(1): E1-4, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25589704

RESUMO

The development of a large hematoma impairing visualization of the distal true lumen is a recognized complication of antegrade recanalization of chronic total occlusions, often forcing the operator to abort the procedure or switch to a retrograde approach. We describe a novel technique utilizing an over-the-wire balloon inflated in the proximal occluded vessel to block inflow and allow aspiration of the blood from the subintimal space. This decompressed the true lumen, restored distal visualization, and allowed successful reentry using a dedicated technology. Utilization of this novel technique may rescue antegrade recanalization attempts complicated by large subintimal hematomas.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Oclusão Coronária/cirurgia , Descompressão Cirúrgica , Hematoma , Hemostasia Cirúrgica , Complicações Intraoperatórias/cirurgia , Complicações Pós-Operatórias/cirurgia , Idoso , Angioplastia Coronária com Balão/métodos , Ponte de Artéria Coronária/efeitos adversos , Oclusão Coronária/diagnóstico , Oclusão Coronária/etiologia , Oclusão Coronária/fisiopatologia , Descompressão Cirúrgica/instrumentação , Descompressão Cirúrgica/métodos , Hematoma/etiologia , Hematoma/cirurgia , Hemostasia Cirúrgica/instrumentação , Hemostasia Cirúrgica/métodos , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Resultado do Tratamento
18.
J Invasive Cardiol ; 16(5): 287-8, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15152120

RESUMO

Renal artery stent implantation is associated with high rates of restenosis, particularly in vessels less than 4.5 mm in diameter. We describe 4-year follow-up results in the first patient to receive renal artery brachytherapy for this indication. A 68-year-old man who presented with flash pulmonary edema, hypertension and renal impairment was found to have severe bilateral renal artery stenosis and was treated with bilateral stent implantation. Following clinical deterioration due to severe in-stent restenosis, he underwent repeat angioplasty followed by intra-stent brachytherapy. To our knowledge, this is the first use of such therapy and hence the 4-year follow-up demonstrating excellent bilateral patency is the longest to date.


Assuntos
Braquiterapia , Obstrução da Artéria Renal/radioterapia , Stents , Idoso , Angiografia , Humanos , Masculino , Edema Pulmonar/etiologia , Recidiva , Obstrução da Artéria Renal/complicações , Obstrução da Artéria Renal/diagnóstico por imagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA