Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37738643

RESUMO

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI. METHODS AND RESULTS: Multi-centre study across 12 centres. Procedural metrics, safety profile, and procedural efficacy of the PolarX Cryoballoon with the Arctic Front Advance (AFA) Cryoballoon were compared in a cohort large enough to provide definitive comparative data. A total of 1688 patients underwent PVI with cryoablation (50% PolarX and 50% AFA). Successful PVI was achieved with 1677 (99.3%) patients with 97.2% (n = 1641) performed as day case procedures with a complication rate of <1%. Safety, procedural metrics, and efficacy of the PolarX Cryoballoon were comparable with the AFA cohort. The PolarX Cryoballoon demonstrated a nadir temperature of -54.6 ± 7.6°C, temperature at 30 s of -38.6 ± 7.2°C, time to -40°C of 34.1 ± 13.7 s, and time to isolation of 49.8 ± 33.2 s. Independent predictors for achieving PVI included time to reach -40°C [odds ratio (OR) 1.34; P < 0.001] and nadir temperature (OR 1.24; P < 0.001) with an optimal cut-off of ≤34 s [area under the curve (AUC) 0.73; P < 0.001] and nadir temperature of ≤-54.0°C (AUC 0.71; P < 0.001), respectively. CONCLUSIONS: This large-scale UK multi-centre study has shown that Cryoballoon PVI is a safe, effective day case procedure. PVI using the PolarX Cryoballoon was similarly safe and effective as the AFA Cryoballoon. The cryoablation metrics achieved with the PolarX Cryoballoon were different to that reported with the AFA Cryoballoon. Modified cryoablation targets are required when utilizing the PolarX Cryoballoon.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Fatores de Tempo , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Reino Unido , Recidiva
2.
Clin Cardiol ; 46(8): 973-980, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37309845

RESUMO

INTRODUCTION: Pulmonary vein (PV) isolation has been shown to reduce atrial fibrillation (AF) burden and symptoms in patients. However, to date previous studies have been unblinded raising the possibility of a placebo effect to account for differences in outcomes. HYPOTHESIS & METHODS: The objective of this study is to compare PV isolation to a sham procedure in patients with symptomatic AF. The SHAM-PVI study is a double blind randomized controlled clinical trial. 140 patients with symptomatic paroxysmal or persistent AF will be randomized to either PV isolation (with cryoballoon ablation) or a sham procedure (with phrenic nerve pacing). All patients will receive an implantable loop recorder. The primary outcome is total AF burden at 6 months postrandomisation (excluding the 3 month blanking period). Key secondary outcomes include (1) time to symptomatic and asymptomatic atrial tachyarrhythmia (2) total atrial tachyarrhythmia episodes and (3) patient reported outcome measures. RESULTS: Enrollment was initiated in January 2020. Through April 2023 119 patients have been recruited. Results are expected to be disseminated in 2024. CONCLUSION: This study compares PV isolation using cryoablation to a sham procedure. The study will estimate the effect of PV isolation on AF burden.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Átrios do Coração , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Método Duplo-Cego , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
3.
Europace ; 24(9): 1420-1429, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35737685

RESUMO

AIM: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon. METHODS AND RESULTS: This prospective multi-centre study included patients that underwent cryoablation for AF. All patients underwent PVI with reconnection assessed after a 30-min waiting period and adenosine. Safety, efficacy, and cryoablation metrics were compared between PolarX and a propensity-matched AFA cohort. Seventy patients were included with 278 veins treated. In total, 359 cryoablations were performed (1.3 ± 0.6 per vein) to achieve initial PVI with 205 (73.7%) veins isolating with a single cryoablation. Independent predictors for achieving initial PVI included temperature at 30 s [odds ratio (OR) 1.26; P = 0.003] and time to reach -40°C (OR 1.88; P < 0.001) with an optimal cut-off of ≤-38.5°C at 30 s [area under the curve (AUC) 0.79; P < 0.001] and ≤-40°C at ≤32.5 s (AUC 0.77; P < 0.001), respectively. Of the 278 veins, 46 (16.5%) veins showed acute reconnection. Temperature at 30 s (≤-39.5°C, OR 1.24; P = 0.002), nadir temperature (≤-53.5°C, OR 1.35; P = 0.003), and time to isolation (≤38.0 s, OR 1.18; P = 0.009) were independent predictors of sustained PVI. Combining two of these three targets was associated with reconnection in only 2-5% of PVs. Efficacy and safety of the PolarX Cryoballoon were comparable to AFA Cryoballoon, however, cryoablation metrics were significantly different. CONCLUSIONS: The PolarX Cryoballoon has a different cryoablation profile to AFA Cryoballoon. Prospective testing of these proposed targets in large outcomes studies is required.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Adenosina , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Benchmarking , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
4.
Circ Arrhythm Electrophysiol ; 13(2): e007377, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31934784

RESUMO

BACKGROUND: ECG imaging (ECGI) has been used to guide treatment of ventricular ectopy and arrhythmias. However, the accuracy of ECGI in localizing the origin of arrhythmias during catheter ablation of ventricular tachycardia (VT) in structurally abnormal hearts remains to be fully validated. METHODS: During catheter ablation of VT, simultaneous mapping was performed using electroanatomical mapping (CARTO, Biosense-Webster) and ECGI (CardioInsight, Medtronic) in 18 patients. Sites of entrainment, pace-mapping, and termination during ablation were used to define the VT site of origin (SoO). Distance between SoO and the site of earliest activation on ECGI were measured using co-registered geometries from both systems. The accuracy of ECGI versus a 12-lead surface ECG algorithm was compared. RESULTS: A total of 29 VTs were available for comparison. Distance between SoO and sites of earliest activation in ECGI was 22.6, 13.9 to 36.2 mm (median, first to third quartile). ECGI mapped VT sites of origin onto the correct AHA segment with higher accuracy than a validated 12-lead ECG algorithm (83.3% versus 38.9%; P=0.015). CONCLUSIONS: This simultaneous assessment demonstrates that CardioInsight localizes VT circuits with sufficient accuracy to provide a region of interest for targeting mapping for ablation. Resolution is not sufficient to guide discrete radiofrequency lesion delivery via catheter ablation without concomitant use of an electroanatomical mapping system but may be sufficient for segmental ablation with radiotherapy.


Assuntos
Ablação por Cateter , Eletrocardiografia/métodos , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Europace ; 21(4): 616-625, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30500897

RESUMO

AIMS: Differences of action potential duration (APD) in regions of myocardial scar and their borderzones are poorly defined in the intact human heart. Heterogeneities in APD may play an important role in the generation of ventricular tachycardia (VT) by creating regions of functional block. We aimed to investigate the transmural and planar differences of APD in patients admitted for VT ablation. METHODS AND RESULTS: Six patients (median age 53 years, five male); (median ejection fraction 35%), were studied. Endocardial (Endo) and epicardial (Epi) 3D electroanatomic mapping was performed. A bipolar voltage of <0.5 mV was defined as dense scar, 0.5-1.5 mV as scar borderzone, and >1.5 mV as normal. Decapolar catheters were positioned transmurally across the scar borderzone to assess differences of APD and repolarization time (RT) during restitution pacing from Endo and Epi. Epi APD was 173 ms in normal tissue vs. 187 ms at scar borderzone and 210 ms in dense scar (P < 0.001). Endocardial APD was 210 ms in normal tissue vs. 222 ms in the scar borderzone and 238 ms in dense scar (P < 0.01). This resulted in significant transmural RT dispersion (ΔRT 22 ms across dense transmural scar vs. 5 ms in normal transmural tissue, P < 0.001), dependent on the scar characteristics in the Endo and Epi, and the pacing site. CONCLUSION: Areas of myocardial scar have prolonged APD compared with normal tissue. Heterogeneity of regional transmural and planar APD result in localized dispersion of repolarization, which may play an important role in initiating VT.


Assuntos
Potenciais de Ação , Ablação por Cateter , Cicatriz/fisiopatologia , Endocárdio/fisiopatologia , Pericárdio/fisiopatologia , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatias/complicações , Cicatriz/etiologia , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Miocardite/complicações , Miocárdio , Recidiva , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo
7.
Artigo em Inglês | MEDLINE | ID: mdl-28705875

RESUMO

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a significant cause of sudden cardiac death in the young. Improved noninvasive assessment of ARVC and better understanding of the disease substrate are important for improving patient outcomes. METHODS AND RESULTS: We studied 20 genotyped ARVC patients with a broad spectrum of disease using electrocardiographic imaging (a method for noninvasive cardiac electrophysiology mapping) and advanced late gadolinium enhancement cardiac magnetic resonance scar imaging. Compared with 20 healthy controls, ARVC patients had longer ventricular activation duration (median, 52 versus 42 ms; P=0.007) and prolonged mean epicardial activation-recovery intervals (a surrogate for local action potential duration; median, 275 versus 241 ms; P=0.014). In these patients, we observed abnormal and varied epicardial activation breakthrough locations and regions of nonuniform conduction and fractionated electrograms. Nonuniform conduction and fractionated electrograms were present in the early concealed phase of ARVC. Electrophysiological abnormalities colocalized with late gadolinium enhancement scar, indicating a relationship with structural disease. Premature ventricular contractions were common in ARVC patients with variable initiation sites in both ventricles. Premature ventricular contraction rate increased with exercise, and within anatomic segments, it correlated with prolonged repolarization, electric markers of scar, and late gadolinium enhancement (all P<0.001). CONCLUSIONS: Electrocardiographic imaging reveals electrophysiological substrate properties that differ in ARVC patients compared with healthy controls. A novel mechanistic finding is the presence of repolarization abnormalities in regions where ventricular ectopy originates. The results suggest a potential role for electrocardiographic imaging and late gadolinium enhancement in early diagnosis and noninvasive follow-up of ARVC patients.


Assuntos
Displasia Arritmogênica Ventricular Direita/diagnóstico , Eletrocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Estudos de Casos e Controles , Cicatriz/fisiopatologia , Meios de Contraste , Diagnóstico Precoce , Feminino , Genótipo , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Meglumina , Pessoa de Meia-Idade , Compostos Organometálicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA