Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
Cancer Res Commun ; 4(5): 1199-1210, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38630886

RESUMO

Homologous recombination (HR)-related gene alterations are present in a significant subset of prostate, breast, ovarian, pancreatic, lung, and colon cancers rendering these tumors as potential responders to specific DNA damaging agents. A small molecule acylfulvene prodrug, LP-184, metabolizes to an active compound by the oxidoreductase activity of enzyme prostaglandin reductase 1 (PTGR1), which is frequently elevated in multiple solid tumor types. Prior work demonstrated that cancer cell lines deficient in a spectrum of DNA damage repair (DDR) pathway genes show increased susceptibility to LP-184. Here, we investigated the potential of LP-184 in targeting multiple tumors with impaired HR function and its mechanism of action as a DNA damaging agent. LP-184 induced elevated DNA double-strand breaks in HR deficient (HRD) cancer cells. Depletion of key HR components BRCA2 or ataxia telangiectasia mutated (ATM) in cancer cells conferred up to 12-fold increased sensitivity to the LP-184. LP-184 showed nanomolar potency in a diverse range of HRD cancer models, including prostate cancer organoids, leiomyosarcoma cell lines, and patient-derived tumor graft models of lung, pancreatic, and prostate cancers. LP-184 demonstrated complete, durable tumor regression in 10 patient-derived xenograft (PDX) models of HRD triple-negative breast cancer (TNBC) including those resistant to PARP inhibitors (PARPi). LP-184 further displayed strong synergy with PARPi in ovarian and prostate cancer cell lines as well as in TNBC PDX models. These preclinical findings illustrate the potential of LP-184 as a pan-HRD cancer therapeutic. Taken together, our results support continued clinical evaluation of LP-184 in a large subset of HRD solid tumors. SIGNIFICANCE: New agents with activity against DDR-deficient solid tumors refractory to standard-of-care therapies are needed. We report multiple findings supporting the potential for LP-184, a novel alkylating agent with three FDA orphan drug designations, to fill this void clinically: strong nanomolar potency; sustained, durable regression of solid tumor xenografts; synthetic lethality with HR defects. LP-184 adult phase IA trial to assess safety in advanced solid tumors is ongoing.


Assuntos
Antineoplásicos , Recombinação Homóloga , Ensaios Antitumorais Modelo de Xenoenxerto , Humanos , Animais , Camundongos , Linhagem Celular Tumoral , Recombinação Homóloga/efeitos dos fármacos , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Neoplasias/tratamento farmacológico , Neoplasias/genética , Feminino , Quebras de DNA de Cadeia Dupla/efeitos dos fármacos , Masculino , Reparo do DNA/efeitos dos fármacos
2.
Cancers (Basel) ; 16(4)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38398103

RESUMO

Prostate cancer represents a significant health risk to aging men, in which diagnostic challenges to the identification of aggressive cancers remain unmet. Prostate cancer screening is driven by the prostate-specific antigen (PSA); however, in men with benign prostatic hyperplasia (BPH) due to an enlarged prostate and elevated PSA, PSA's screening utility is diminished, resulting in many unnecessary biopsies. To address this issue, we previously identified a cleaved fragment of Filamin A (FLNA) protein (as measured with IP-MRM mass spectrometry assessment as a prognostic biomarker for stratifying BPH from prostate cancer and subsequently evaluated its expanded utility in Caucasian (CA) and African American (AA) men. All men had a negative digital rectal examination (DRE) and PSA between 4 and 10 ng/mL and underwent prostate biopsy. In AA men, FLNA serum levels exhibited diagnostic utility for stratifying BPH from patients with aggressive prostate cancer (0.71 AUC and 12.2 OR in 48 men with BPH and 60 men with PCa) and outperformed PSA (0.50 AUC, 2.2 OR). In CA men, FLNA serum levels also exhibited diagnostic utility for stratifying BPH from patients with aggressive prostate cancer (0.74 AUC and 19.4 OR in 191 men with BPH and 109 men with PCa) and outperformed PSA (0.46 AUC, 0.32 OR). Herein, we established FLNA alone as a serum biomarker for stratifying men with BPH vs. those with high Gleason (7-10) prostate cancers compared to the current diagnostic paradigm of using PSA. This approach demonstrates clinical actionability of FLNA alone without the requirement of prostate volume measurement as a test with utility in AA and CA men and represents a significant opportunity to decrease the number of unnecessary biopsies in aggressive prostate cancer diagnoses.

3.
Biomedicines ; 11(5)2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37239075

RESUMO

Growing evidence indicates the involvement of a genetic component in prostate cancer (CaP) susceptibility and clinical severity. Studies have reported the role of germline mutations and single nucleotide polymorphisms (SNPs) of TP53 as possible risk factors for cancer development. In this single institutional retrospective study, we identified common SNPs in the TP53 gene in AA and CA men and performed association analyses for functional TP53 SNPs with the clinico-pathological features of CaP. The SNP genotyping analysis of the final cohort of 308 men (212 AA; 95 CA) identified 74 SNPs in the TP53 region, with a minor allele frequency (MAF) of at least 1%. Two SNPs were non-synonymous in the exonic region of TP53: rs1800371 (Pro47Ser) and rs1042522 (Arg72Pro). The Pro47Ser variant had an MAF of 0.01 in AA but was not detected in CA. Arg72Pro was the most common SNP, with an MAF of 0.50 (0.41 in AA; 0.68 in CA). Arg72Pro was associated with a shorter time to biochemical recurrence (BCR) (p = 0.046; HR = 1.52). The study demonstrated ancestral differences in the allele frequencies of the TP53 Arg72Pro and Pro47Ser SNPs, providing a valuable framework for evaluating CaP disparities among AA and CA men.

4.
J Immunol Methods ; 518: 113493, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37196930

RESUMO

BACKGROUND: Aberrant ETV1 overexpression arising from gene rearrangements or mutations occur frequently in prostate cancer, round cell sarcomas, gastrointestinal stromal tumors, gliomas, and other malignancies. The absence of specific monoclonal antibodies (mAb) has limited its detection and our understanding of its oncogenic function. METHODS: An ETV1 specific rabbit mAb (29E4) was raised using an immunogenic peptide. Key residues essential for its binding were probed by ELISA and its binding kinetics were measured by surface plasmon resonance imaging (SPRi). Its selective binding to ETV1 was assessed by immunoblots and immunofluorescence assays (IFA), and by both single and double-immuno-histochemistry (IHC) assays on prostate cancer tissue specimens. RESULTS: Immunoblot results showed that the mAb is highly specific and lacked cross-reactivity with other ETS factors. A minimal epitope with two phenylalanine residues at its core was found to be required for effective mAb binding. SPRi measurements revealed an equilibrium dissociation constant in the picomolar range, confirming its high affinity. ETV1 (+) tumors were detected in prostate cancer tissue microarray cases evaluated. IHC staining of whole-mounted sections revealed glands with a mosaic staining pattern of cells that are partly ETV1 (+) and interspersed with ETV1 (-) cells. Duplex IHC, using ETV1 and ERG mAbs, detected collision tumors containing glands with distinct ETV1 (+) and ERG (+) cells. CONCLUSIONS: The selective detection of ETV1 by the 29E4 mAb in immunoblots, IFA, and IHC assays using human prostate tissue specimens reveals a potential utility for the diagnosis, the prognosis of prostate adenocarcinoma and other cancers, and the stratification of patients for treatment by ETV1 inhibitors.


Assuntos
Neoplasias da Próstata , Fatores de Transcrição , Masculino , Humanos , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo , Proteínas de Ligação a DNA/genética , Anticorpos Monoclonais , Neoplasias da Próstata/diagnóstico , Immunoblotting
5.
J Clin Med ; 12(3)2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36769553

RESUMO

Dose-calculation algorithms are critical for radiation treatment outcomes that vary among treatment planning systems (TPS). Modern algorithms use sophisticated radiation transport calculation with detailed three-dimensional beam modeling to provide accurate doses, especially in heterogeneous medium and small fields used in IMRT/SBRT. While the dosimetric accuracy in heterogeneous mediums (lung) is qualitatively known, the accuracy is unknown. The aim of this work is to analyze the calculated dose in lung patients and compare the validity of dose-calculation algorithms by measurements in a low-Z phantom for two main classes of algorithms: type A (pencil beam) and type B (collapse cone). The CT scans with volumes (target and organs at risk, OARs) of a lung patient and a phantom build to replicate the human lung data were sent to nine institutions for planning. Doses at different depths and field sizes were measured in the phantom with and without inhomogeneity correction across multiple institutions to understand the impact of clinically used dose algorithms. Wide dosimetric variations were observed in target and OAR coverage in patient plans. The correction factor for collapsed cone algorithms was less than pencil beam algorithms in the small fields used in SBRT. The pencil beam showed ≈70% variations between measured and calculated correction factors for various field sizes and depths. For large field sizes the trends of both types of algorithms were similar. The differences in measured versus calculated dose for type-B algorithms were within ±10%. Significant variations in the target and OARs were observed among various TPS. The results suggest that the pencil beam algorithm does not provide an accurate dose and should not be considered with small fields (IMRT/SBRT). Type-B collapsed-cone algorithms provide better agreement with measurements, but still vary among various systems.

6.
J Appl Clin Med Phys ; 24(3): e13857, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36519493

RESUMO

This study provides insight into the overall system performance, stability, and delivery accuracy of the first clinical self-shielded stereotactic radiosurgery (SRS) system. Quality assurance procedures specifically developed for this unit are discussed, and trends and variations over the course of 2-years for beam constancy, targeting and dose delivery are presented. Absolute dose calibration for this 2.7 MV unit is performed to deliver 1 cGy/MU at dmax  = 7 mm at a source-to-axis-distance (SAD) of 450 mm for a 25 mm collimator. Output measurements were made with 2-setups: a device that attaches to a fixed position on the couch (daily) and a spherical phantom that attaches to the collimating wheel (monthly). Beam energy was measured using a cylindrical acrylic phantom at depths of 100 (D10 ) and 200 (D20 ) mm. Beam profiles were evaluated using Gafchromic film and compared with TPS beam data. Accuracy in beam targeting was quantified with the Winston-Lutz (WL) and end-to-end (E2E) tests. Delivery quality assurance (DQA) was performed prior to clinical treatments using Gafchromic EBT3/XD film. Net cumulative output adjustments of 15% (pre-clinical), 9% (1st year) and 3% (2nd year) were made. The mean output was 0.997 ± 0.010 cGy/MU (range: 0.960-1.046 cGy/MU) and 0.993 ± 0.029 cGy/MU (range: 0.884-1.065 cGy/MU) for measurements with the daily and monthly setups, respectively. The mean relative beam energy (D10 /D20 ) was 0.998 ± 0.004 (range: 0.991-1.006). The mean total targeting error was 0.46 ± 0.17 mm (range: 0.06-0.98 mm) for the WL and 0.52 ± 0.28 mm (range: 0.11-1.27 mm) for the E2E tests. The average gamma pass rates for DQA measurements were 99.0% and 90.5% for 2%/2 mm and 2%/1 mm gamma criteria, respectively. This SRS unit meets tolerance limits recommended by TG-135, MPPG 9a., and TG-142 with a treatment delivery accuracy similar to what is achieved by other SRS systems.


Assuntos
Radiocirurgia , Humanos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Aceleradores de Partículas , Imagens de Fantasmas , Calibragem , Planejamento da Radioterapia Assistida por Computador/métodos
7.
Med Phys ; 49(12): 7733-7741, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35964159

RESUMO

BACKGROUND: Methods for accurate absolute dose (AD) calibration are essential for the proper functioning of radiotherapy treatment machines. Many systems do not conform to TG-51 calibration standards, and modifications are required. TG-21 calibration is also a viable methodology for these situations with the appropriate setup, equipment, and factors. It has been shown that both these methods result in minimal errors. A similar approach has been taken in calibrating the dose for a recent vault-free radiosurgery system. PURPOSE: To evaluate modified TG-21 and TG-51 protocols for AD calibrations of the ZAP-X radiosurgery system using ion chambers, film, and thermoluminescent dosimeters (TLDs). METHODS: The current treatment planning system for ZAP-X requires AD calibration at dmax (7 mm) and 450 mm source-to-axis distance. Both N D , w 60 C o [ G y / C ] $N_{D,w}^{{60}Co}[ {Gy/C} ]$ and Nx [R/C] calibration coefficients were provided by an accredited dosimetry calibration laboratory for a physikalisch technische werkstatten (PTW) 31010 chamber (0.125 cc). The vendor provides an f-bracket that can be mounted on the collimator. Various phantoms can then be attached to the f-bracket. A custom acrylic phantom was designed based on recommendations from TG-21 and technical report series-398 that places the chamber at 500 mm from the source with a depth of 44-mm acrylic and 456-mm SSD. Nx along with other TG-21 parameters was used to calculate the AD. Measurements using a PTW MP3-XS water tank and the same chamber were used to calculate AD using N D , w 60 C o $N_{D,w}^{{60}Co}$ and TG-51 factors. Dose verification was performed using Gafchromic film and 3rd party TLDs. RESULTS: Measurements from TG-51, TG-21 (utilizing the custom acrylic phantom), film, and TLDs agreed to within ± 2%. CONCLUSIONS: A modified TG-51 AD calculation in water is preferred but may not be practical due to the difficulty in tank setup. The TG-21 modified protocol using a custom acrylic phantom is an accurate alternative option for dose calibration. Both of these methods are within acceptable agreement and provide confidence in the system's AD calibration.


Assuntos
Fenilpropionatos , Radiocirurgia , Radiocirurgia/métodos , Radiometria , Imagens de Fantasmas , Calibragem , Água
8.
Technol Cancer Res Treat ; 21: 15330338221106852, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35712977

RESUMO

Introduction: Brachytherapy using permanently implantable collagen tiles containing cesium-131 (Cs-131) is indicated for treatment of malignant intracranial neoplasms. We quantified Cs-131 source migration and modeled the resulting dosimetric impact for Cs-131, iodine-125 (I-125), and palladium-103 (Pd-103). Methods and Materials: This was a retrospective analysis of a subgroup of patients enrolled in a prospective, single-center, nonrandomized, clinical trial (NCT03088579) of Cs-131 collagen tile brachytherapy. Postimplant Cs-131 plans and hypothetical I-125 and Pd-103 calculations were compared for 20 glioblastoma patients for a set seed geometry. Dosimetric impact of decay and seed migration was calculated for 2 hypothetical scenarios: Scenario 1, assuming seed positions on a given image set were unchanged until acquisition of the subsequent set; Scenario 2, assuming any change in seed positions occurred the day following acquisition of the prior images. Seed migration over time was quantified for a subset of 7 patients who underwent subsequent image-guided radiotherapy. Results: Mean seed migration was 1.7 mm (range: 0.7-3.1); maximum seed migration was 4.3 mm. Mean dose to the 60 Gy volume differed by 0.4 Gy (0.6%, range 0.1-1.0) and 0.9 Gy (1.5%, range 0.2-1.7) for Cs-131, 1.2 Gy (2.0%, range 0.1-2.1) and 1.6 Gy (2.6%, range 1.2-2.6) for I-125, and 0.8 Gy (1.3%, range 0.2-1.5) and 1.4 Gy (2.3%, range 0.3-1.9) for Pd-103, for Scenarios 1 and 2, respectively, compared with the postimplant plan. For a set seed geometry mean implant dose was higher for Pd-103 (1.3 times) and I-125 (1.1 times) versus Cs-131. Dose fall-off was steepest for Pd-103: gradient index 1.88 versus 2.23 (I-125) and 2.40 (Cs-131). Conclusions: Dose differences due to source migration were relatively small, suggesting robust prevention of seed migration from Cs-131-containing collagen tiles. Intratarget heterogeneity was greater with Pd-103 and I-125 than Cs-131. Dose fall-off was fastest with Pd-103 followed by I-125 and then Cs-131.


Assuntos
Braquiterapia , Neoplasias Encefálicas , Braquiterapia/métodos , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/radioterapia , Radioisótopos de Césio/uso terapêutico , Humanos , Radioisótopos do Iodo/uso terapêutico , Paládio/uso terapêutico , Estudos Prospectivos , Radioisótopos , Dosagem Radioterapêutica , Estudos Retrospectivos
9.
Nat Commun ; 13(1): 1361, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35292633

RESUMO

In prostate cancer, emerging data highlight the role of DNA damage repair genes (DDRGs) in aggressive forms of the disease. However, DDRG mutations in African American men are not yet fully defined. Here, we profile germline mutations in all known DDRGs (N = 276) using whole genome sequences from blood DNA of a matched cohort of patients with primary prostate cancer comprising of 300 African American and 300 European Ancestry prostate cancer patients, to determine whether the mutation status can enhance patient stratification for specific targeted therapies. Here, we show that only 13 of the 46 DDRGs identified with pathogenic/likely pathogenic mutations are present in both African American and European ancestry patients. Importantly, RAD family genes (RAD51, RAD54L, RAD54B), which are potentially targetable, as well as PMS2 and BRCA1, are among the most frequently mutated DDRGs in African American, but not in European Ancestry patients.


Assuntos
Negro ou Afro-Americano , Neoplasias da Próstata , Negro ou Afro-Americano/genética , Dano ao DNA/genética , Mutação em Linhagem Germinativa , Humanos , Masculino , Mutação , Neoplasias da Próstata/genética , Neoplasias da Próstata/patologia
10.
Sci Rep ; 12(1): 5404, 2022 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-35354846

RESUMO

TP53 is one of the most frequently altered genes in prostate cancer. The precise assessment of its focal alterations in primary tumors by immunohistochemistry (IHC) has significantly enhanced its prognosis. p53 protein expression and lymphovascular invasion (LVI) were evaluated for predicting metastatic progression by IHC staining of representative whole-mounted prostate sections from a cohort of 189 radical prostatectomy patients with up to 20 years of clinical follow-up. Kaplan-Meier survival curves were used to examine time to distant metastasis (DM) as a function of p53 expression and LVI status. TP53 targeted sequencing was performed in ten tumors with the highest expression of p53 staining. Nearly half (49.8%) of prostate tumors examined showed focal p53 expression while 26.6% showed evidence of LVI. p53(+) tumors had higher pathologic T stage, Grade Group, Nuclear Grade, and more frequent LVI. p53 expression of > 5% and LVI, individually and jointly, are associated with poorer DM-free survival. TP53 mutations were detected in seven of ten tumors sequenced. Four tumors with the highest p53 expression harbored likely pathogenic or pathogenic mutations. High levels of p53 expression suggest the likelihood of pathogenic TP53 alterations and, together with LVI status, could enhance early prognostication of prostate cancer progression.


Assuntos
Próstata , Neoplasias da Próstata , Humanos , Imuno-Histoquímica , Masculino , Prognóstico , Próstata/patologia , Neoplasias da Próstata/genética , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/cirurgia , Proteína Supressora de Tumor p53/genética , Proteína Supressora de Tumor p53/metabolismo
12.
ACS Med Chem Lett ; 12(11): 1703-1709, 2021 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-34790292

RESUMO

Prostate cancer is among the leading causes of cancer related death of men in the United States. The ERG gene fusion leading to overexpression of near full-length ERG transcript and protein represents most prevalent (50-65%) prostate cancer driver gene alterations. The ERG oncoprotein overexpression persists in approximately 35% of metastatic castration resistant prostate cancers. Due to the emergence of eventual refractoriness to second- and third-generation androgen axis-based inhibitors, there remains a pressing need to develop drugs targeting other validated prostate cancer drivers such as ERG. Here we report the new and more potent ERG inhibitor ERGi-USU-6 developed by structure-activity studies from the parental ERGi-USU. We have developed an improved procedure for the synthesis of ERGi-USU-6 and identified a salt formulation that further improves its activity in biological assays for selective targeting of ERG harboring prostate cancer cells.

13.
Med Phys ; 48(11): 6881-6888, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34628668

RESUMO

PURPOSE: Magnetic resonance imaging (MRI) is commonly used in treatment planning for stereotactic radiosurgery (SRS) of trigeminal neuralgia (TN). With current MRI techniques, the delineation of the trigeminal nerve root entry zone (REZ) may be degraded due to poor contrast and artifacts. The purpose of this work is to develop an MRI technique with better delineation of the trigeminal nerve REZ to improve SRS treatment planning for TN. METHODS: A spiral fluid-attenuated inversion recovery (FLAIR) MRI technique was developed to improve image quality by improving tissue contrast, fluid suppression, artifact reduction, and signal-to-noise ratio (SNR). A concomitant-phase compensation method based on spiral gradient waveforms was implemented to minimize artifacts due to magnetic field change induced by the metal frame used in Gamma Knife treatment planning. The image quality of spiral FLAIR was assessed in four healthy volunteers. The geometric accuracy was quantitatively evaluated by registering spiral FLAIR to computed tomography (CT) images and comparing it with existing MRI techniques. RESULTS: The spiral FLAIR technique demonstrated better delineation of the trigeminal nerve REZ, improved tissue contrast of the brain stem, and minimized flow artifacts, compared to steady-state free precession (SSFP) MRI. Spiral FLAIR also improved fluid suppression, SNR, and artifacts, which contributed to better delineation of the trigeminal nerve REZ compared to conventional Cartesian FLAIR. The measured mean (± standard deviation) distance between spiral FLAIR and CT images is 0.98 ± 0.56 mm, comparable to 0.40 ± 0.26 mm in 3T T1 spoiled gradient echo (T1-SPGR), 0.59 ± 0.25 mm in 3T SSFP, 0.66 ± 0.38 mm in 1.5T T1-SPGR, and 0.61 ± 0.25 mm in 1.5T Cartesian FLAIR. CONCLUSION: A spiral FLAIR technique with improved image quality and good geometric accuracy provides a potential alternative for treatment planning in SRS for TN patients.


Assuntos
Radiocirurgia , Neuralgia do Trigêmeo , Artefatos , Humanos , Imageamento por Ressonância Magnética , Nervo Trigêmeo/diagnóstico por imagem , Nervo Trigêmeo/cirurgia , Neuralgia do Trigêmeo/diagnóstico por imagem , Neuralgia do Trigêmeo/radioterapia , Neuralgia do Trigêmeo/cirurgia
14.
Med Phys ; 48(10): 6121-6136, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34260069

RESUMO

PURPOSE: This study reports a single-institution experience with beam data acquisition and film-based validation for a novel self-shielded sterotactic radiosurgery unit and investigates detector dependency on field output factors (OFs), off-axis ratios (OARs), and percent depth dose (PDD) measurements within the context of small-field dosimetry. METHODS: The delivery platform for this unit consists of a 2.7-MV S-band linear accelerator mounted on coupled gimbals that rotate around a common isocenter (source-to-axis distance [SAD] = 450 mm), allowing for more than 260 noncoplanar beam angles. Beam collimation is achieved via a tungsten collimator wheel with eight circular apertures ranging from 4 mm to 25 mm in diameter. Three diodes (PTW 60012 Diode E, PTW 60018 SRS Diode, and Sun Nuclear EDGE) and a synthetic diamond detector (PTW 60019 micro Diamond [µD] detector) were used for OAR, PDD, and OF measurements. OFs were also acquired with a PTW 31022 PinPoint ionization chamber. Beam scanning was performed using a 3D water tank at depths of 7, 50, 100, 200, and 250 mm with a source-to-surface distance of 450 mm. OFs were measured at the depth of maximum dose (dmax  = 7 mm) with the SAD at 450 mm. Gafchromic EBT3 film was used to validate OF and profile measurements and as a reference detector for estimating correction factors for active detector OFs. Deviations in field size, penumbra, and PDDs across the different detectors were quantified. RESULTS: Relative OFs (ROFs) for the diodes were within 1.4% for all collimators except for 5 and 7.5 mm, for which SRS Diode measurements were higher by 1.6% and 2.6% versus Diode E. The µD ROFs were within 1.4% of the diode measurements. PinPoint ROFs were lower by >10% for the 4-mm and 5-mm collimators versus the Diode E and µD. Corrections to OFs using EBT3 film as a reference were within 1.2% for all diodes and the µD detector for collimators 10 mm and greater and within 2.0%, 2.8%, and 1.1% for the 7.5-, 5-, and 4-mm collimators, respectively. The maximum difference in full width at half maximum (FWHM) between the Diode E and the other active detectors was for the 25-mm collimator and was 0.09 mm (µD), 0.16 mm (SRS Diode), and 0.65 mm (EDGE). Differences seen in PDDs beyond the depth of dmax were <1% across the three diodes and the µD. FWHM and penumbra measurements made using EBT3 film were within 1.34% and 3.26%, respectively, of the processed profile data entered into the treatment planning system. CONCLUSIONS: Minimal differences were seen in OAR and PDD measurements acquired with the diodes and the µD. ROFs measured with the three diodes were within 2.6% and within 1.4% versus the µD. Gafchromic Film measurements provided independent verification of the OAR and OF measurements. Estimated corrections to OFs using film as a reference were <1.6% for the Diode E, EDGE, and µD detector.


Assuntos
Radiocirurgia , Diamante , Método de Monte Carlo , Aceleradores de Partículas , Radiometria
15.
Sci Rep ; 11(1): 15052, 2021 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-34302010

RESUMO

Prostate-specific antigen (PSA) screening for prostate cancer (PCa) is limited by the lack of specificity but is further complicated in the benign prostatic hyperplasia (BPH) population which also exhibit elevated PSA, representing a clear unmet need to distinguish BPH from PCa. Herein, we evaluated the utility of FLNA IP-MRM, age, and prostate volume to stratify men with BPH from those with PCa. Diagnostic performance of the biomarker panel was better than PSA alone in discriminating patients with negative biopsy from those with PCa, as well as those who have had multiple prior biopsies (AUC 0.75 and 0.87 compared to AUC of PSA alone 0.55 and 0.57 for patients who have had single compared to multiple negative biopsies, respectively). Of interest, in patients with PCa, the panel demonstrated improved performance than PSA alone in those with Gleason scores of 5-7 (AUC 0.76 vs. 0.56) and Gleason scores of 8-10 (AUC 0.74 vs. 0.47). With Gleason scores (8-10), the negative predictive value of the panel is 0.97, indicating potential to limit false negatives in aggressive cancers. Together, these data demonstrate the ability of the biomarker panel to perform better than PSA alone in men with BPH, thus preventing unnecessary biopsies.


Assuntos
Biomarcadores Tumorais/sangue , Diagnóstico Diferencial , Hiperplasia Prostática/diagnóstico , Neoplasias da Próstata/diagnóstico , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Próstata/metabolismo , Antígeno Prostático Específico/sangue , Hiperplasia Prostática/sangue , Hiperplasia Prostática/patologia , Neoplasias da Próstata/sangue , Neoplasias da Próstata/patologia
16.
Radiology ; 299(3): 613-623, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33847515

RESUMO

Background Although prostate MRI is routinely used for the detection and staging of localized prostate cancer, imaging-based assessment and targeted molecular sampling for risk stratification are an active area of research. Purpose To evaluate features of preoperative MRI and MRI-guided biopsy immunohistochemistry (IHC) findings associated with biochemical recurrence (BCR) of prostate cancer after surgery. Materials and Methods In this retrospective case-control study, patients underwent multiparametric MRI before MRI-guided biopsy followed by radical prostatectomy between 2008 and 2016. Lesions were retrospectively scored with the Prostate Imaging Reporting and Data System (PI-RADS) (version 2) by radiologists who were blinded to the clinical-pathologic results. The IHC staining, including stains for the ETS-related gene, phosphatase and tensin homolog, androgen receptor, prostate specific antigen, and p53, was performed with targeted biopsy specimens of the index lesion (highest suspicion at MRI and pathologic grade) and scored by pathologists who were blinded to clinical-pathologic outcomes. Cox proportional hazards regression analysis was used to evaluate associations with recurrence-free survival (RFS). Results The median RFS was 31.7 months (range, 1-101 months) for 39 patients (median age, 62 years; age range, 47-76 years) without BCR and 14.6 months (range, 1-61 months) for 40 patients (median age, 59 years; age range, 47-73 years) with BCR. MRI features that showed a significant relationship with the RFS interval included an index lesion with a PI-RADS score of 5 (hazard ratio [HR], 2.10; 95% CI: 1.05, 4.21; P = .04); index lesion burden, defined as ratio of index lesion volume to prostate volume (HR, 1.55; 95% CI: 1.2, 2.1; P = .003); and suspicion of extraprostatic extension (EPE) (HR, 2.18; 95% CI: 1.1, 4.2; P = .02). Presurgical multivariable analysis indicated that suspicion of EPE at MRI (adjusted HR, 2.19; 95% CI: 1.1, 4.3; P = .02) and p53 stain intensity (adjusted HR, 2.22; 95% CI: 1.0, 4.7; P = .04) were significantly associated with RFS. Conclusion MRI features, including Prostate Imaging Reporting and Data System score, index lesion burden, extraprostatic extension, and preoperative guided biopsy p53 immunohistochemistry stain intensity are associated with biochemical relapse of prostate cancer after surgery. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Costa in this issue.


Assuntos
Biópsia Guiada por Imagem , Imuno-Histoquímica , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Idoso , Estudos de Casos e Controles , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Prostatectomia , Neoplasias da Próstata/patologia , Estudos Retrospectivos
17.
Med Phys ; 48(5): 2494-2510, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33506520

RESUMO

PURPOSE: To evaluate the treatment planning system (TPS) performance of the ZAP-X stereotactic radiosurgery (SRS) system through nondosimetric, dosimetric, and end-to-end (E2E) tests. METHODS: A comprehensive set of TPS commissioning and validation tests was developed using published guidelines. Nondosimetric validation tests included information transfer, computed tomography-magnetic resonance (CT-MR) image registration, structure/contouring, geometry, dose tools, and CT density. Dosimetric validation included comparisons between TPS and water tank/Solid Water measurements for various geometries and beam arrangements and end-to-end (E2E) tests. Patient-specific quality assurance was performed with an ion chamber in the Lucy phantom and with Gafchromic EBT3 film in the CyberKnife head phantom. RadCalc was used for independent verification of monitor units. Additional E2E tests were performed using the RPC Gamma Knife thermoluminescent dosimeter (TLD) phantom, MD Anderson SRS head phantom, and PseudoPatient gel phantom for independent absolute dose verification. RESULTS: CT-MR image registrations with known translational and rotational offsets were within tolerance (<0.5 × maximum voxel dimension). Slice thickness and distance accuracy were within 0.1 mm, and volume accuracy was within 0 to 0.11 cm3 . Treatment planning system volume measurement uncertainty was within 0.1 to 0.4 cm3 . Ion chamber point-dose measurements for a single beam in a water phantom agreed to TPS-calculated values within ±4% for collimator diameters 10 to 25 mm, and ±6% for 7.5 mm, for all measured depths (7, 50, 100, 150, and 200 mm). In homogeneous Solid Water, point-dose measurements agreed to within ±4% for cones sizes 7.5 to 25 mm. With 1-cm high/low density inserts, measurements were within ±4.2% for cone sizes 10 to 25 mm. Film-based E2E using 4/5-mm cones resulted in a gamma passing rate (%GP) of 99.8% (2%/1.5 mm). Point-dose measurements in a Lucy phantom with an ion chamber using 36 beams distributed along three noncoplanar arcs agreed to within ±4% for cone sizes 10 to 25 mm. The RPC Gamma Knife TLD phantom yielded passing results with a measured-to-expected TLD dose ratio of 1.02. The MD Anderson SRS head phantom yielded passing results, with 4% TLD agreement and %GP of 95%/93% (5%/3 mm) for coronal/sagittal film planes. The RTsafe gel phantom gave %GP of >95% (5%/2 mm) for all four targets. For our first 58 patients, film-based patient-specific quality assurance has resulted in an average %GP of 98.7% (range, 94-100%) at 2%/2 mm. CONCLUSIONS: Core ZAP-X features were found to be functional. On the basis of our results, point-dose and planar measurements were in agreement with TPS calculations using multiple phantoms and setup geometries, validating the ZAP-X TPS beam model for clinical use.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Cabeça , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
18.
Int J Cancer ; 148(1): 99-105, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32930425

RESUMO

Polygenic hazard score (PHS) models are associated with age at diagnosis of prostate cancer. Our model developed in Europeans (PHS46) showed reduced performance in men with African genetic ancestry. We used a cross-validated search to identify single nucleotide polymorphisms (SNPs) that might improve performance in this population. Anonymized genotypic data were obtained from the PRACTICAL consortium for 6253 men with African genetic ancestry. Ten iterations of a 10-fold cross-validation search were conducted to select SNPs that would be included in the final PHS46+African model. The coefficients of PHS46+African were estimated in a Cox proportional hazards framework using age at diagnosis as the dependent variable and PHS46, and selected SNPs as predictors. The performance of PHS46 and PHS46+African was compared using the same cross-validated approach. Three SNPs (rs76229939, rs74421890 and rs5013678) were selected for inclusion in PHS46+African. All three SNPs are located on chromosome 8q24. PHS46+African showed substantial improvements in all performance metrics measured, including a 75% increase in the relative hazard of those in the upper 20% compared to the bottom 20% (2.47-4.34) and a 20% reduction in the relative hazard of those in the bottom 20% compared to the middle 40% (0.65-0.53). In conclusion, we identified three SNPs that substantially improved the association of PHS46 with age at diagnosis of prostate cancer in men with African genetic ancestry to levels comparable to Europeans.


Assuntos
População Negra/estatística & dados numéricos , Predisposição Genética para Doença , Modelos Genéticos , Herança Multifatorial , Neoplasias da Próstata/epidemiologia , Fatores Etários , População Negra/genética , Estudos de Casos e Controles , Técnicas de Genotipagem , Humanos , Masculino , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único , Modelos de Riscos Proporcionais , Neoplasias da Próstata/genética
19.
J Urol ; 205(2): 420-425, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32945736

RESUMO

PURPOSE: Prostate cancer is predominantly indolent at diagnosis with a small fraction (15% to 25%) representing aggressive subtype (Gleason score 7-10), which is prone to metastatic progression. It is critical to explore noninvasive assays for the early detection of this aggressive subtype, when it still can be treated effectively. Additionally, there is an emerging need to develop markers that perform equally well across races, as racial differences in the prevalence and mortality of prostate cancer has become evident. MATERIALS AND METHODS: First catch, nondigital rectal examination urine specimens were collected from patients undergoing diagnostic biopsy. Total RNA was extracted from urinary exosomes and a quantitative expression assay protocol using droplet digital polymerase chain reaction was developed for detection of candidate genes in exosomal mRNAs from urine. Clinical performance for the gene expression assay was evaluated to predict high grade cancer (Gleason score 7-10) from low grade cancer (Gleason score 6) and cancer negative cases at biopsy. Assay performance was examined in combination with standard of care to determine improvement in model prediction. RESULTS: In a racially diverse patient cohort a 2-gene panel (PCA3, PCGEM1), in combination with standard of care variables, significantly improved the prediction of high grade cancer at diagnosis compared to standard of care variables alone (AUC 0.88 vs 0.80, respectively, p=0.016). Decision curve analysis showed that there is a benefit of adopting the gene panel for detection of high grade cancer compared to standard of care alone. CONCLUSIONS: This study highlights the potential for developing broadly applicable prostate cancer diagnostic biomarker panels for aggressive prostate cancer using our novel gene expression assay platform.


Assuntos
Exossomos/genética , Regulação Neoplásica da Expressão Gênica , Neoplasias da Próstata/genética , Neoplasias da Próstata/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Estudos de Coortes , Diagnóstico Diferencial , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/urina
20.
Pathology ; 53(2): 205-213, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32967771

RESUMO

ANXA2 (Annexin A2 or Annexin II) is a calcium dependent phospholipid binding protein with diverse cellular functions. While ANXA2 is either absent or expressed focally in the prostate epithelium of well and moderately differentiated tumours, it is highly expressed in a subset of poorly differentiated tumours. Here we examined the association between ANXA2 expression and tumour progression, with consideration of ERG expression status and patient race (Caucasian American and African American). We evaluated ANXA2 and ERG expression in index tumours by immunohistochemistry of whole mounted prostate sections and tissue microarrays derived from radical prostatectomies of 176 patients, matched for long term post-radical prostatectomy follow-up of up to 22 years (median 12.6 years), race and pathological stage. Expression of ERG and ANXA2 was analysed for correlation with grade group (GG), and pathological T (pT) stage. Kaplan-Meier estimation curves were used to examine associations between ANXA2 or ERG expression and biochemical recurrence (BCR) free survival, and distant metastasis free survival. Significant associations were found between ANXA2(+) index tumours and poorest grade groups (GG 4-5, p=0.0037), and worse pathological stage (pT 3-4, p=0.0142). Patients with ANXA2(+) prostate tumours showed trends towards earlier BCR and metastatic progression. ANXA2(+)/ERG(-) tumours were found to be associated with GG 4-5; ANXA2(-)/ERG(+) tumours, with GG 1-2 (p=0.0036). ANXA2 expression was not associated with patient race. The association between high ANXA2 expression and prostate tumours of higher grade (GG 4-5) and stage (pT 3-4) suggests a potential use for ANXA2 as a prognostic biomarker of aggressive prostate cancer.


Assuntos
Anexina A2 , Prognóstico , Neoplasias da Próstata , Anexina A2/análise , Anexina A2/metabolismo , Biomarcadores Tumorais/análise , Biomarcadores Tumorais/metabolismo , Progressão da Doença , Humanos , Imuno-Histoquímica , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Próstata/patologia , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Regulador Transcricional ERG/análise , Regulador Transcricional ERG/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA