RESUMO
BACKGROUND: The incidence of acetabular fractures in osteoporotic patients is increasing. Immediate total hip arthroplasty (THA) has potential advantages, but achieving acetabular component stability is challenging and, at early followup, reported revision rates for loosening are high. QUESTIONS/PURPOSES: This study measured acetabular component stability and the initial surface contact achieved between the acetabular component and unfractured region of the pelvis after THA using an oversized acetabular component and cup-cage reconstruction. METHODS: Between November 2011 and November 2013, we treated 40 acute acetabular fractures in patients older than 70 years of age. Of these, 12 (30%) underwent immediate THA using an oversized acetabular component with screws inserted only into the ilium and a cup-cage construct. Postoperatively all patients were mobilized without weightbearing restrictions. Indications for immediate THA after acetabular fractures were displaced articular comminution deemed unreducible. Eleven of the 12 were prospectively studied to evaluate the initial stability of the reconstructions using radiostereometric analysis. One of the patients died of a pulmonary embolism after surgery, and the remaining 10 (median age, 81 years; range, 72-86 years) were studied. Of these, five were analyzed at 1 year and five were analyzed at 2 years. Acetabular component migration was defined as acceptable if less than the limits for primary THA that predict later loosening (1.76 mm of proximal migration and 2.53° of sagittal rotation). The contact surface between the acetabular component and ilium in direct continuity with the sacroiliac joint, and the ischium and pubis in direct continuity with the symphysis pubis, was measured on postoperative CT scans. RESULTS: At 1 year the median proximal migration was 0.83 mm (range, 0.09-5.13 mm) and sagittal rotation was 1.3° (range, 0.1°-7.4°). Three of the 10 components had migration above the suggested limits for primary THA at 1 year postoperatively. The contact surface achieved at surgery between the acetabular component and pelvis ranged from 11 to 17 cm(2) (15%-27% of each component). CONCLUSIONS: The majority of acetabular components in this cohort were stable despite the small contact surface achieved between the component and pelvic bone. Three of 10 migrated in excess of the limits that predict later loosening in primary THA but it remains to be seen whether these limits apply to this selected group of frail osteoporotic patients. We continue to use this technique routinely to treat patients with the same indications, but since the analysis of these data we have added screw fixation of the acetabular component to the ischial tuberosity and the superior pubic ramus. LEVEL OF EVIDENCE: Level IV, therapeutic study.
Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Fraturas do Quadril/cirurgia , Prótese de Quadril , Instabilidade Articular/prevenção & controle , Fraturas por Osteoporose/cirurgia , Falha de Prótese , Acetábulo/diagnóstico por imagem , Acetábulo/lesões , Acetábulo/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Densidade Óssea , Feminino , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/fisiopatologia , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/etiologia , Instabilidade Articular/fisiopatologia , Masculino , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Radiografia , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
Using computed tomography, the volume, location, and number of osteolytic lesions were determined adjacent to 38 Harris-Galante 1 (HG-1) acetabular components fixed with screws and 19 porous-coated anatomic (PCA) acetabular components press-fitted without screws. The median implantation times were 16 and 15 years, respectively. The mean total lesion volumes were similar: 11.1 cm(3) (range, 0.7-49 cm(3)) and 9.8 cm(3) (range, 0.4-52 cm(3)), respectively, for hips with HG-1 and PCA components (P = .32). There was a significant difference in the proportion of rim-related, screw or screw hole-related, and combined lesions between the 2 component designs (P < .0001). HG-1 components had more screw and screw hole-related lesions, and PCA components had more rim-related lesions. Although there are concerns regarding screw and screw hole-associated osteolysis, these findings suggest that peripheral fixation may be well maintained in the long term with the use of multiple-hole acetabular components with screw fixation.