Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Vasc Surg ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38723909

RESUMO

OBJECTIVE: To evaluate the impact of celiac artery (CA) compression by median arcuate ligament (MAL) on technical metrics and long-term CA patency in patients with complex aortic aneurysms undergoing fenestrated/branched endograft repairs (F/B-EVARs). METHODS: Single-center, retrospective review of patients undergoing fenestrated/branched endovascular aortic aneurysm repairs and requiring incorporation of the CA between 2013 and 2023. Patients were divided into two groups-those with (MAL+) and without (MAL-) CA compression-based on preoperative computed tomography angiography findings. MAL was classified in three grades (A, B, and C) based on the degree and length of stenosis. Patients with MAL grade A had ≤50% CA stenosis measuring ≤3 mm in length. Those with grade B had 50% to 80% CA stenosis measuring 3 to 8 mm long, whereas those with grade C had >80% stenosis measuring >8 mm in length. End points included device integrity, CA patency and technical success-defined as successful implantation of the fenestrated/branched device with perfusion of CA and no endoleak. RESULTS: One hundred and eighty patients with complex aortic aneurysms (pararenal, 128; thoracoabdominal, 52) required incorporation of the CA during fenestrated/branched endovascular aortic aneurysm repair. Majority (73%) were male, with a median age of 76 years (interquartile range [IQR], 69-81 years) and aneurysm size of 62 mm (IQR, 57-69 mm). Seventy-eight patients (43%) had MAL+ anatomy, including 33 patients with MAL grade A, 32 with grade B, and 13 with grade C compression. The median length of CA stenosis was 7.0 mm (IQR, 5.0-10.0 mm). CA was incorporated using fenestrations in 177 (98%) patients. Increased complexity led to failure in CA bridging stent placement in four MAL+ patients, but completion angiography showed CA perfusion and no endoleak, accounting for a technical success of 100%. MAL+ patients were more likely to require bare metal stenting in addition to covered stents (P = .004). Estimated blood loss, median operating room time, contrast volume, fluoroscopy dose and time were higher (P < .001) in MAL+ group. Thirty-day mortality was 3.3%, higher (5.1%) in MAL+ patients compared with MAL- patients (2.0 %). At a median follow-up of 770 days (IQR, 198-1525 days), endograft integrity was observed in all patients and CA events-kinking (n = 7), thrombosis (n = 1) and endoleak (n = 2) -occurred in 10 patients (5.6%). However, only two patients required reinterventions. MAL+ patients had overall lower long-term survival. CONCLUSIONS: CA compression by MAL is a predictor of increased procedural complexity during fenestrated/branched device implantation. However, technical success, long-term device integrity and CA patency are similar to that of patients with MAL- anatomy.

2.
Ann Thorac Surg ; 117(6): 1154-1162, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38382704

RESUMO

BACKGROUND: Selection of transcatheter valve size using preprocedural computed tomography (CT) is standardized and well established. However, valve sizing for surgical aortic valve replacement (SAVR) is currently performed intraoperatively by using sizers, which may result in variation among operators and risk for prosthesis-patient mismatch. This study evaluated the usefulness of CT annulus measurement for SAVR valve sizing. METHODS: This study included patients who underwent SAVR using Inspiris or Magna Ease and received preoperative electrocardiogram-gated CT imaging. Starting from June 2022, study investigators applied a CT sizing algorithm using CT-derived annulus size to guide minimum SAVR label size. The final decision of valve selection was left to the operating surgeon during SAVR. The study compared the appropriateness of valve selection (comparing implanted size with CT-predicted size) and prosthesis-patient mismatch rates without aortic root enlargement between 2 cohorts: 102 cases since June 2022 (CT sizing cohort) and 180 cases from 2020 to 2021 (conventional sizing cohort). RESULTS: Implanted size smaller than CT predicted size and severe prosthesis-patient mismatch were significantly lower by CT sizing than by conventional sizing (12% vs 31% [P = .001] and 0% vs 6% [P = .039], respectively). Interoperator variability was a factor associated with implanted size smaller than CT predicted with conventional sizing, whereas it became nonsignificant with CT sizing. CONCLUSIONS: Applying CT sizing to SAVR led to improved valve size selection, less prosthesis-patient mismatch, and less interoperator variability. CT sizing for SAVR could also be used to predict prosthesis-patient mismatch before SAVR and identify patients who need aortic root enlargement.


Assuntos
Valva Aórtica , Próteses Valvulares Cardíacas , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Tomografia Computadorizada por Raios X/métodos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Idoso , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Desenho de Prótese , Idoso de 80 Anos ou mais , Cuidados Pré-Operatórios/métodos , Implante de Prótese de Valva Cardíaca/métodos , Substituição da Valva Aórtica Transcateter/métodos
3.
J Vasc Surg ; 79(5): 1101-1109, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38103807

RESUMO

OBJECTIVE: To evaluate outcomes and performance of inverted limbs (ILs) when used in conjunction with Zenith fenestrated stent grafts (Zfens) to treat patients with short distance between the lowest renal artery (RA) and aortic or graft bifurcation (A/GB). METHODS: This study was a multicenter, retrospective review of prospectively maintained database of patients with complex aortic aneurysms, failed endovascular aneurysm repair (EVAR), or open surgical repair (OSR) with short distance between LRA and A/GB treated using a combination of Zfen and an IL between 2013 and 2023. Endpoints included technical success, aneurysm sac regression, long-term device integrity, and target vessel patency. We defined technical success as implantation of the device with no endoleak, conversion to an aorto-uni-iliac or OSR. RESULTS: During this time, 52 patients underwent endovascular rescue of failed repair. Twenty (38.5%) of them required relining of the failed repairs using IL due to lowest RA to A/GB length restrictions. Two patients had undergone rescue with a fenestrated cuff alone but developed type III endoleaks. One patient with no previous implant had a short distance between the lowest RA and aortic bifurcation to accommodate the bifurcated distal device, and two patients had failed OSR or anastomotic pseudoaneurysms. The majority (94%) were men with a mean age of 76.8 ± 6.1 years. The mean aortic neck diameter and aneurysm size were 32 ± 4 cm and 7.2 ± 1.3 cm, respectively. The median time laps between initial repair and failure was 36 months (interquartile range [IQR], 24-54 months). Sixteen patients (80%) were classified as American Society of Anesthesiologists class III, whereas four were class IV. Seventy-eight vessels were targeted and successfully incorporated. Technical success was 100%, and median estimated blood loss was 100 mL (IQR, 100-200 mL). Mean fluoroscopy time and dose were 61 ± 18 minutes and 2754 ± 1062 mGy, respectively. Average hospital length of stay was 2.75 ± 2.15 days. Postoperative complication occurred in one patient who required lower extremity fasciotomy for compartment syndrome. At a median follow-up of 50 months (IQR, 18-58 months), there were no device migration, components separation, aneurysmal related mortality, and type I or type III endoleak. Aneurysm sac regression (95%) or stabilization (5%) was observed in all patients, including in four patients (25%) with type II endoleak. CONCLUSIONS: The use of IL in conjunction with Zfen to treat patients with short distance between the lowest RA and A/GB is safe, effective, and has excellent long-term results. The technique expands the indication of Zfen, especially in patients with failed previous EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Médicos , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Stents , Endoleak/etiologia , Endoleak/cirurgia , Fatores de Risco , Resultado do Tratamento , Desenho de Prótese , Estudos Retrospectivos
4.
Arq. bras. cardiol ; 116(1): 100-105, Jan. 2021. tab
Artigo em Inglês, Português | LILACS | ID: biblio-1152972

RESUMO

Resumo Fundamento Qualidade de imagem e dose de radiação são otimizadas com uma frequência cardíaca (FC) lenta e estável na realização de imagens de artérias coronárias durante a angiografia cardíaca por tomografia computadorizada (CCTA, do inglês cardiac computed tomography angiography) A segurança, a eficácia e o protocolo para a redução da FC com medicamento betabloqueador ainda não foi bem descrita em uma população de pacientes pediátricos. Objetivo Oferecer um protocolo de dose de metoprolol eficiente a ser usado em pacientes pediátricos externos durante a CCTA. Métodos Realizamos uma revisão retrospectiva de todos os pacientes pediátricos externos que receberam o metoprolol durante a CCTA. As características demográficas e clínicas foram resumidas e a redução média em FC foi estimada utilizando-se um modelo de regressão linear multivariada. As imagens foram avaliadas em uma escala de 1 a 4 (1= ideal). Resultados Um total de 78 pacientes externos passaram a uma CCTA com o uso de metoprolol. A média de idade foi de 13 anos, a média de peso foi de 46 kg, e 36 pacientes (46%) eram do sexo masculino. As doses médias de metoprolol foram 1,5 (IQR 1,1; 1,8) mg/kg, e 0,4 (IQR 0,2; 0,7) mg/kg para administrações orais e intravenosas, respectivamente. O produto dose-comprimento por exame foi de 57 (IQR 30, 119) mGy*cm. A redução média da FC foi 19 (IQR 12, 26) batimentos por minuto, ou 23%. Não foram relatadas complicações ou eventos adversos. Conclusão O uso de metoprolol num cenário de pacientes pediátricos externos para redução da FC antes de uma CCTA é seguro e eficiente. Pode-se reproduzir um protocolo de dose de metoprolol quando for necessário atingir uma FC mais lenta, garantindo tempos de aquisição mais rápidos, imagens mais claras e redução na exposição à radiação nessa população. (Arq Bras Cardiol. 2021; 116(1):100-105)


Abstract Background Image quality and radiation dose are optimized with a slow, steady heart rate (HR) when imaging the coronary arteries during cardiac computed tomography angiography (CCTA). The safety, efficacy, and protocol for HR reduction with beta blocker medication is not well described in a pediatric patient population. Objective Provide a safe and efficient metoprolol dose protocol to be used in pediatric outpatients undergoing CCTA. Methods We conducted a retrospective review of all pediatric outpatients who received metoprolol during CCTA. Demographic and clinical characteristics were summarized and the average reduction in HR was estimated using a multivariate linear regression model. Images were evaluated on a 1-4 scale (1= optimal). Results Seventy-eight pediatric outpatients underwent a CCTA scan with the use of metoprolol. The median age was 13 years, median weight of 46 kg, and 36 (46%) were male. The median doses of metoprolol were 1.5 (IQR 1.1, 1.8) mg/kg and 0.4 (IQR 0.2, 0.7) mg/kg for oral and intravenous administrations, respectively. Procedural dose-length product was 57 (IQR 30, 119) mGy*cm. The average reduction in HR was 19 (IQR 12, 26) beats per minute, or 23%. No complications or adverse events were reported. Conclusion Use of metoprolol in a pediatric outpatient setting for HR reduction prior to CCTA is safe and effective. A metoprolol dose protocol can be reproduced when a slower HR is needed, ensuring faster acquisition times, clear images, and associated reduction in radiation exposure in this population. (Arq Bras Cardiol. 2021; 116(1):100-105)


Assuntos
Humanos , Masculino , Criança , Adolescente , Doença da Artéria Coronariana , Metoprolol/efeitos adversos , Pacientes Ambulatoriais , Doses de Radiação , Estudos Retrospectivos , Angiografia Coronária , Angiografia por Tomografia Computadorizada , Frequência Cardíaca
5.
J Perinatol ; 40(8): 1193-1201, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32433510

RESUMO

OBJECTIVE: To test the hypothesis that infants born <30 weeks' gestation supported by Seattle-PAP will have lower rates of continuous positive airway pressure (CPAP) failure than infants supported with conventional, Fisher&Paykel-CPAP (FP-CPAP). STUDY DESIGN: Randomized trial (3/2017-01/2019) at 5 NICUs. The primary outcome was CPAP failure; subgroup analyses (gestational age, receipt antenatal corticosteroids) were performed. RESULTS: A total of 232 infants were randomized. Infants in the Seattle-PAP and FP-CPAP groups had mean gestational ages of 27.0 and 27.2 weeks, respectively. We observed no differences in rates of treatment failure between Seattle-PAP (40/112, 35.7%) and FP-CPAP (38/120, 31.7%; risk difference, 4.1%; 95% CI, -8.1-16.2; P = 0.51). Subgroup analysis indicated no differences in rates of CPAP failure. We observed no differences between the two groups in frequencies of adverse events or duration of respiratory support. CONCLUSIONS: Among infants born <30 weeks' gestation, rates of CPAP failure did not differ between Seattle-PAP and FP-CPAP.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Síndrome do Desconforto Respiratório do Recém-Nascido , Feminino , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Gravidez , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia
6.
Circ Cardiovasc Interv ; 12(3): e007338, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30871357

RESUMO

BACKGROUND: We examined the procedural outcomes of chronic total occlusions (CTO) percutaneous coronary interventions in patients with prior coronary artery bypass graft surgery (CABG). METHODS AND RESULTS: We compared the clinical, angiographic characteristics and outcomes of 3486 CTO interventions performed in patients with (n=1101) and without (n=2317) prior CABG at 21 centers. Prior CABG patients (32% of total cohort) were older (67±9 versus 63±10 years; P<0.001) and had more comorbidities and lower left ventricular ejection fraction (50% [40-58] versus 55% [45-60]; P<0.001). The CTO target vessel in prior CABG patients was the right coronary artery (56%), circumflex (26%), and left anterior descending artery (17%). The mean J-CTO (2.9±1.2 versus 2.2±1.3; P<0.001) and PROGRESS-CTO (Prospective Global Registry for the Study of Chronic Total Occlusion Intervention; 1.5±1.1 versus 1.2±1.0; P<0.001) score was higher in prior CABG patients. Retrograde (53% versus 30%, P<0.001) and antegrade dissection reentry (35% versus 28%; P<0.001) techniques were used more frequently in prior CABG patients. Prior CABG patients had lower technical (84% versus 89%; P<0.001) and procedural (82% versus 87%, P<0.001) success, but similar incidence of in-hospital major complications (3.1% versus 2.5%; P=0.287). In-hospital mortality (1% versus 0.4%; P=0.016) and coronary perforation (7.1% versus 3.1%; P<0.001) occurred more frequently in prior CABG patients, however, CABG patients had a lower incidence of pericardial tamponade (0.1% versus 1.0%; P=0.002) and pericardiocentesis (0% versus 1.3%; P<0.001). CONCLUSIONS: In a large multicenter CTO percutaneous coronary interventions registry, prior CABG patients had lower success rate but similar overall risk for complications, although mortality was higher and the incidence of tamponade was lower. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02061436.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Oclusão Coronária/terapia , Intervenção Coronária Percutânea , Idoso , Doença Crônica , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/mortalidade , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Europa (Continente) , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Retrospectivos , Fatores de Risco , Federação Russa , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
7.
JACC Cardiovasc Interv ; 12(4): 346-358, 2019 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-30784639

RESUMO

OBJECTIVES: This study examined the frequency and outcomes of radial access for chronic total occlusion (CTO) percutaneous coronary intervention (PCI). BACKGROUND: Radial access improves the safety of PCI, but its role in CTO PCI remains controversial. METHODS: We compared the clinical, angiographic, and procedural characteristics of 3,790 CTO interventions performed between 2012 and 2018 via radial-only access (RA) (n = 747) radial-femoral access (RFA) (n = 844) and femoral-only access (n = 2,199) access at 23 centers in the United States, Europe, and Russia. RESULTS: Patients' mean age was 65 ± 10 years, and 85% were men. Transradial access (RA and RFA) was used in 42% of CTO interventions and significantly increased over time from 11% in 2012 to 67% in 2018 (p < 0.001). RA patients were younger (age 62 ± 10 years vs. 64 ± 10 years and 65 ± 10 years; p < 0.001), less likely to have undergone prior coronary artery bypass graft surgery (18% vs. 39% and 35%; p < 0.001), and less likely to have undergone prior PCI (60% vs. 63% and 66%; p = 0.005) compared with those who underwent RFA and femoral-only access PCI. RA CTO PCI lesions had lower J-CTO (Multicenter CTO Registry in Japan) (2.1 ± 1.4 vs. 2.6 ± 1.3 and 2.5 ± 1.3; p < 0.001) and PROGRESS CTO (Prospective Global Registry for the Study of Chronic Total Occlusion Intervention) complication (2.3 ± 1.9 vs. 3.2 ± 2.0 and 3.2 ± 1.9; p < 0.001) scores. The mean sheath size was significantly smaller in the RA group (6.6 ± 0.7 vs. 7.0 ± 0.6 and 7.3 ± 0.8; p < 0.0001), although it increased with lesion complexity. Antegrade dissection re-entry (20% vs. 33% and 32%; p < 0.001) was less commonly used with RA, whereas use of retrograde techniques was highest with RFA (47%). The overall rates of technical success (89% vs. 88% vs. 86%; p = 0.061), procedural success (86% vs. 85% vs. 85%; p = 0.528), and in-hospital major complication (2.47% vs. 3.40% vs. 2.18%; p = 0.830) were similar in all 3 groups, whereas major bleeding was lower in the RA group (0.55% vs. 1.94% and 0.88%; p = 0.013). CONCLUSIONS: Transradial access is increasingly being used for CTO PCI and is associated with similar technical and procedural success and lower major bleeding rates compared with femoral-only access interventions. (Prospective Global Registry for the Study of Chronic Total Occlusion Intervention [PROGRESS CTO]; NCT02061436).


Assuntos
Cateterismo Periférico , Oclusão Coronária/terapia , Artéria Femoral , Intervenção Coronária Percutânea , Artéria Radial , Idoso , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Europa (Continente) , Feminino , Artéria Femoral/diagnóstico por imagem , Hemorragia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Punções , Artéria Radial/diagnóstico por imagem , Sistema de Registros , Medição de Risco , Fatores de Risco , Federação Russa , Resultado do Tratamento , Estados Unidos
8.
Cardiovasc Revasc Med ; 20(4): 289-292, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30054257

RESUMO

BACKGROUND/PURPOSE: Patients and lesions at a higher procedural risk for percutaneous coronary intervention (PCI) are an understudied population. We examined the frequency, clinical characteristics, and outcomes of higher risk and non-higher risk PCIs at a large tertiary center. METHODS/MATERIALS: The following procedures were considered higher risk: unprotected left main PCI, chronic total occlusion PCI, PCI requiring atherectomy, multivessel PCI, bifurcation PCI, PCI in prior coronary artery bypass graft surgery (CABG) patients, pre-PCI left ventricular ejection fraction ≤30%, or use of hemodynamic support. RESULTS: Of the 1975 PCIs performed from 6/29/09 to 12/30/2016 in patients without acute coronary syndromes, 1230 (62%) were higher risk. Patients undergoing higher risk PCI were more likely to have a history of CABG, myocardial infarction, PCI, cerebrovascular disease, peripheral arterial disease, or congestive heart failure. Higher risk PCIs required more stents (2.0 vs. 1.0, p < 0.001), and had longer median fluoroscopy times (17.3 vs. 8.5 min, p < 0.001) and higher median contrast doses (160 vs. 120 mL, p < 0.001). In higher risk PCIs, the risks for technical failure and periprocedural complications were 2.9 (95% CI 1.2-7.4) times and 2.2 (95% CI 0.9-5.4) times higher as compared with non-higher risk PCI procedures. CONCLUSIONS: In summary, over half of the PCIs performed in non-acute coronary syndrome patients were higher risk and were associated with lower odds of technical success and higher periprocedural complication rates as compared with non-higher risk PCIs. SUMMARY: We examined the frequency, clinical characteristics, and outcomes of higher risk and non-higher risk PCIs at a large tertiary center. Higher risk PCI was associated with lower odds of technical and procedural success and higher odds of procedural complications as compared with non-higher risk PCI. However, the risk/benefit ratio may still be favorable for many of these higher-risk patients and should be estimated on a case by case basis.


Assuntos
Síndrome Coronariana Aguda/terapia , Intervenção Coronária Percutânea/tendências , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/mortalidade , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Prevalência , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Centros de Atenção Terciária/tendências , Fatores de Tempo , Resultado do Tratamento
9.
PLoS One ; 13(3): e0193807, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29590143

RESUMO

BACKGROUND: Almost one million prematurely born infants die annually from respiratory insufficiency, predominantly in countries with limited access to respiratory support for neonates. The primary hypothesis tested in the present study was that a modified device for bubble nasal continuous positive airway pressure (Bn-CPAP) would provide lower work of spontaneous breathing, estimated by esophageal pressure-rate products. METHODS: Infants born <32 weeks gestation and stable on Bn-CPAP with FiO2 <0.30 were studied within 72 h following delivery. Esophageal pressures during spontaneous breathing were measured during 2 h on standard Bn-CPAP, then 2 h with Bn-CPAP using a modified bubble device presently termed Seattle-PAP, which produces a different pattern of pressure fluctuations and which provided greater respiratory support in preclinical studies, then 2 h on standard Bn-CPAP. RESULTS: All 40 infants enrolled completed the study and follow-up through 36 wks post menstrual age or hospital discharge, whichever came first. No infants were on supplemental oxygen at completion of follow-up. No infants developed pneumothoraces or nasal trauma, and no adverse events attributed to the study were observed. Pressure-rate products on the two devices were not different, but effort of breathing, assessed by areas under esophageal pressure-time curves, was lower with Seattle-PAP than with standard Bn-CPAP. CONCLUSION: Use of Seattle-PAP to implement Bn-CPAP lowers the effort of breathing exerted even by relatively healthy spontaneously breathing premature neonates. Whether the lower effort of breathing observed with Seattle-PAP translates to improvements in neonatal mortality or morbidity will need to be determined by studies in appropriate patient populations.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Recém-Nascido Prematuro/fisiologia , Respiração , Ampicilina/uso terapêutico , Análise de Variância , Antibacterianos/uso terapêutico , Área Sob a Curva , Esôfago/efeitos dos fármacos , Esôfago/fisiopatologia , Feminino , Seguimentos , Gentamicinas/uso terapêutico , Frequência Cardíaca , Humanos , Lactente , Recém-Nascido , Modelos Lineares , Masculino , Esforço Físico/efeitos dos fármacos , Pressão , Respiração/efeitos dos fármacos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA