Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Coron Artery Dis ; 34(5): 364-371, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37139563

RESUMO

Coronary artery anomalies are a diverse group of congenital disorders presenting with highly variable clinical manifestations. The anomalous origin of left circumflex artery from the right coronary sinus following a retro-aortic trajectory is a well-recognized anatomic variation. Despite its benign course, it can prove lethal in association with valvular surgery. When single aortic valve replacement or combined with mitral valve replacement is performed, the aberrant coronary vessel may be compressed by or between the prosthetic rings triggering postoperative lateral myocardial ischemia. If left untreated, the patient is at risk of sudden death or myocardial infarction with its detrimental complications. Skeletonization and mobilization of the aberrant coronary artery is the most widely accepted intervention, but valve downsizing or concomitant surgical or transcatheter revascularization have also been described. However, large series are lacking from the literature. Therefore, no guidelines exist. This study is a thorough review of the literature concerning the aforementioned anomaly in association with valvular surgery.


Assuntos
Doença da Artéria Coronariana , Seio Coronário , Anomalias dos Vasos Coronários , Próteses Valvulares Cardíacas , Humanos , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doença da Artéria Coronariana/complicações
2.
J Card Surg ; 36(11): 4189-4195, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34448500

RESUMO

BACKGROUND AND AIM OF THE STUDY: HAART 300 is an internal geometric annuloplasty ring. The safety and efficacy of this novel device in aortic valve (AV) repair in a single referral center are reported. METHODS: Twenty patients with trileaflet AV insufficiency with ascending aorta and/or aortic root enlargement were included. Subannular implantation was performed to correct annular dilatation, whereas concomitant leaflet repair was performed whenever required. All but two patients also received ascending aorta replacement, whereas selective sinus replacement was performed in all but five patients. RESULTS: Follow-up was for a maximum of 3.8 years and a mean of 2.2 years. Mean age was 54.2 years old. Moderate to severe preoperative AV insufficiency was noted in 75% of patients, whereas 70% of them had an ascending aorta over 45 mm. One patient was lost from follow-up. Overall mortality as well as major complication rates were zero. Early postoperatively, no more than mild AV regurgitation was detected, whereas only one patient appeared with moderate AV regurgitation during our 2.2-year follow-up. New York Heart Association class was also significantly lower compared to preoperative values and valve gradients remained low at last follow-up. CONCLUSIONS: Geometric ring annuloplasty is a safe and effective valve sparing approach to deal with AV insufficiency contributing to overall root reconstruction. Short-term results are excellent rendering this easily reproducible and versatile method very attractive.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Terapia Antirretroviral de Alta Atividade , Aorta , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA