Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur J Radiol ; 172: 111329, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38278010

RESUMO

PURPOSE: To determine accurate organ doses, effective doses, and image quality of computed tomography (CT) compared with cone beam CT (CBCT) for correct identification of prostatic arteries. METHOD: A dual-energy CT scanner and a flat-panel angiography system were used. Dose measurements (gallbladder (g), intestine (i), bladder (b), prostate (p), testes (t), active bone marrow of pelvis (bmp) and femura (bmf)) were performed using an anthropomorphic phantom with 65 thermoluminescent dosimeters in the pelvis and abdomen region. For the calculation of the contrast-to-noise ratio (CNR) of the pelvic arteries, a patient whose weight and height were almost identical to those of the phantom was selected for each examination type. RESULTS: The effective dose of CT was 2.7 mSv and that of CBCT was 21.8 mSv. Phantom organ doses were lower for CT than for CBCT in all organs except the testes (g: 1.2 mGy vs. 3.3 mGy, i: 5.8 mGy vs. 23.9 mGy, b: 6.9 mGy vs. 19.4 mGy, p: 6.4 mGy vs. 13.2 mGy, t: 4.7 mGy vs. 2.4 mGy, bmp: 5.1 mGy vs. 18.2 mGy, bmf: 3.3 mGy vs. 6.6 mGy). For human pelvic arteries, the CNR of CT was better than that of CBCT, with the exception of one prostate artery that showed stenosis on CT. Evaluation by experienced radiologists also confirmed the better detectability of prostate arteries on CT examination. CONCLUSIONS: In our study preprocedural CT had lower organ doses and better image quality comparedd with CBCT and should be considered for the correct identification of prostatic arteries.


Assuntos
Exposição à Radiação , Tomografia Computadorizada de Feixe Cônico Espiral , Masculino , Humanos , Tomografia Computadorizada por Raios X , Tomografia Computadorizada de Feixe Cônico/métodos , Abdome , Imagens de Fantasmas , Doses de Radiação
2.
Pediatr Radiol ; 52(6): 1125-1133, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35460347

RESUMO

BACKGROUND: Various imaging modalities, such as multi-detector computed tomography (CT) and cone beam CT are commonly used in infants for the diagnosis of hearing loss and surgical planning of implantation hearing aid devices, with differing results. OBJECTIVE: We compared three different imaging modalities available in our institution, including a high-class CT scanner, a mid-class CT scanner and an angiography system with a cone beam CT option, for image quality and radiation exposure in a phantom study. MATERIALS AND METHODS: While scanning an anthropomorphic phantom imitating a 1-year-old child with vendor-provided routine protocols, organ doses, surface doses and effective doses were determined for these three modalities with thermoluminescent dosimeters. The image quality was evaluated using the signal difference to noise ratio (SDNR) and the spatial resolution of a line-pair insert in the phantom head. The dose efficiency, defined as the ratio of SDNR and effective dose, was also compared. RESULTS: The organ and surface doses were lowest with the high-class CT protocol, but the image quality was the worst. Image quality was best with the cone beam CT protocol, which, however, had the highest radiation exposure in this study, whereas the mid-class CT was in between. CONCLUSION: Based on our results, high-end CT should be used for surgical planning because it has the lowest dose, while the image quality is still sufficient for this purpose. However, if highest image quality is needed and required, e.g., by ENT surgeons, the other modalities should be considered.


Assuntos
Osso Petroso , Exposição à Radiação , Criança , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Lactente , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
3.
Rofo ; 193(7): 778-786, 2021 Jul.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-33327031

RESUMO

BACKGROUND: The exposure of a pregnant woman to X-rays is an event that can cause uncertainty for all concerned. This review provides guidance on how to assess such a situation and how to determine the dose to the unborn child. In general, the use of X-rays in pregnant women in radiology should be avoided. If possible, alternatives should be used, or examinations postponed to a time after the pregnancy. This review gives a summary of the procedure for determining the radiation exposure of a pregnant woman. METHOD: Based on the previous report of 2002 and the literature on prenatal radiation exposure published thereafter, the DGMP/DRG report on the procedure for the assessment of prenatal radiation exposure was adapted to the current state of science and technology. RESULTS: Typically, only relatively low radiation exposures of less than 20 mSv occur for the unborn child in X-ray diagnostics in the vast majority of cases. At these dose level the additional risk of damage to the embryo or fetus caused by the radiation is low and therefore only a rough conservative estimate using tabulated values are made. Only in a few types of examination (CT and interventional radiology) higher doses values might occur in the uterus. Instead of dose estimates (step 1 in the two-step model) in these cases the calculation of dose (step 2) are required and further action by the physician may be necessary. CONCLUSIONS: During the assessment, it is useful to initially use simple conservative estimation procedures to quickly determine whether a case falls into this large group less than 20 mSv, where there is a very low risk to the unborn child. If this is the case, the pregnant woman should be informed immediately by the doctor who performed the examination/treatment. This avoids a psychological burden on the patient. The DGMP/DRG report suggests a relatively simple, clearly structured procedure with advantages for all parties involved (physician, medical physics experts, MTRA and patient). KEY POINTS: · The DGMP/DRG report on prenatal radiation exposure describes the procedure for calculating radiation exposures and the associated risks for the unborn child.. · Using the two-step model, only a simple assessment based on the first step is necessary for most prenatal radiation exposures.. · With the given tables it is possible to estimate individual risks for the unborn child taking into account the radiation exposure.. · Only in the rare case that the first estimate results in a uterine dose larger 20 mSv a more accurate calculation is necessary.. CITATION FORMAT: · Fiebich M, Block A, Borowski M et al. Prenatal radiation exposure in diagnostic and interventional radiology. Fortschr Röntgenstr 2021; 193: 778 - 786.


Assuntos
Feto/efeitos da radiação , Doses de Radiação , Exposição à Radiação/efeitos adversos , Radiologia Intervencionista , Relação Dose-Resposta à Radiação , Feminino , Humanos , Gravidez , Exposição à Radiação/análise
4.
Cardiovasc Intervent Radiol ; 43(8): 1194-1201, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32342165

RESUMO

PURPOSE: To assess radiation exposure in men undergoing prostate artery embolization (PAE) for the treatment for symptomatic, benign prostatic hyperplasia depending on growing experience of interventional radiologists over a 4-year period. METHODS: A total of 250 consecutive patients underwent PAE at a single center. Data on radiation exposure [dose area product (DAP), effective dose (ED), entrance skin dose (ESD), and fluoroscopy time (FT)] were retrospectively evaluated. Primary outcomes of interest were patient radiation exposure in five consecutive groups of 50 patients each and Pearson correlation with the number of patients treated. RESULTS: Median DAP, ED, and ESD during prostate artery embolization were significantly higher in the first compared to the second 50 patients (56 298 µGym2 vs. 24 709 µGym2, p < 0.001, 146.4 mSv vs. 64.2 mSv, p < 0.001, and 5.1 Gy vs. 2.4 Gy, p < 0.001, respectively). The following consecutive groups did not differ significantly from the respective preceding group in terms of DAP, ED, and ESD. Number of digital subtraction angiography series, FT, and procedure time decreased with increasing operator experience (Pearson's r = - 0.240, p < 0.001, r = - 0.269, p < 0.001, and r = - 0.504, p < 0.001, respectively). Bilateral prostate artery embolization was associated with less ESD and shorter FT than unilateral embolization (median 2.5 vs. 3.5 Gy, p = 0.02, and 26 min vs. 42 min, p < 0.001, respectively). CONCLUSION: Exposure to radiation in men who underwent PAE decreased with growing operator experience and decreasing complexity of procedures.


Assuntos
Competência Clínica/estatística & dados numéricos , Embolização Terapêutica/métodos , Segurança do Paciente/estatística & dados numéricos , Hiperplasia Prostática/terapia , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/métodos , Idoso , Angiografia Digital , Humanos , Masculino , Próstata/irrigação sanguínea , Próstata/diagnóstico por imagem , Radiologistas , Estudos Retrospectivos , Resultado do Tratamento
5.
Strahlenther Onkol ; 193(1): 46-54, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27812732

RESUMO

PURPOSE: This project compares the different patient-related quality assurance systems for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques currently used in the central Germany area with an independent measuring system. MATERIALS AND METHODS: The participating institutions generated 21 treatment plans with different combinations of treatment planning systems (TPS) and linear accelerators (LINAC) for the QUASIMODO (Quality ASsurance of Intensity MODulated radiation Oncology) patient model. The plans were exposed to the ArcCHECK measuring system (Sun Nuclear Corporation, Melbourne, FL, USA). The dose distributions were analyzed using the corresponding software and a point dose measured at the isocenter with an ionization chamber. RESULTS: According to the generally used criteria of a 10 % threshold, 3 % difference, and 3 mm distance, the majority of plans investigated showed a gamma index exceeding 95 %. Only one plan did not fulfill the criteria and three of the plans did not comply with the commonly accepted tolerance level of ±3 % in point dose measurement. CONCLUSION: Using only one of the two examined methods for patient-related quality assurance is not sufficiently significant in all cases.


Assuntos
Neoplasias/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/normas , Radioterapia (Especialidade) , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/normas , Análise de Falha de Equipamento , Alemanha , Fidelidade a Diretrizes/normas , Humanos , Assistência Centrada no Paciente/normas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA