Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
JACC Cardiovasc Imaging ; 17(1): 79-95, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37731368

RESUMO

Tricuspid regurgitation (TR) is a highly prevalent and heterogeneous valvular disease, independently associated with excess mortality and high morbidity in all clinical contexts. TR is profoundly undertreated by surgery and is often discovered late in patients presenting with right-sided heart failure. To address the issue of undertreatment and poor clinical outcomes without intervention, numerous structural tricuspid interventional devices have been and are in development, a challenging process due to the unique anatomic and physiological characteristics of the tricuspid valve, and warranting well-designed clinical trials. The path from routine practice TR detection to appropriate TR evaluation, to conduction of clinical trials, to enriched therapeutic possibilities for improving TR access to treatment and outcomes in routine practice is complex. Therefore, this paper summarizes the key points and methods crucial to TR detection, quantitation, categorization, risk-scoring, intervention-monitoring, and outcomes evaluation, particularly of right-sided function, and to clinical trial development and conduct, for both interventional and surgical groups.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Diagnóstico por Imagem , Valor Preditivo dos Testes , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Ensaios Clínicos como Assunto
2.
Can J Cardiol ; 38(10 Suppl1): S66-S78, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34464691

RESUMO

Tricuspid regurgitation is associated with excessive mortality and poor outcomes regardless of the cause and associated comorbidities. Despite this clear association with mortality, tricuspid valve diseases remain undertreated. Tricuspid valve surgery, either repair or replacement, has shown little detectable survival benefit. Transcatheter tricuspid valve interventions have emerged as a less invasive approach to tricuspid valve diseases. They can be categorised into coaptation devices, annuloplasty devices, transcatheter tricuspid valve replacement, heterotopic caval valve implantation, and tricuspid valve-in-valve. Despite the late referral and the patient's profile, results remain fairly acceptable at least in the short term, with good procedural device success, excellent safety profile, and sustained reduction of tricuspid regurgitation for up to 1 year. Because results are limited to the mid-term, transcatheter tricuspid valve intervention durability will need to be established before broader adoption of these technologies.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia
3.
JACC Heart Fail ; 9(6): 453-462, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33992567

RESUMO

OBJECTIVES: This study sought to determine the effect of percutaneous mitral valve annuloplasty with the Carillon device versus guideline-directed medical therapy (GDMT) alone in patients with secondary mitral regurgitation (MR) and severe left ventricular (LV) enlargement. BACKGROUND: The clinical impact of the Carillon device in patients with severe LV dilation is not well established. METHODS: This is a pooled analysis involving 3 prospective trials (TITAN [Transcatheter Implantation of Carillon Mitral Annuloplasty Device], TITAN II, and REDUCE FMR [CARILLON Mitral Contour System for Reducing Functional Mitral Regurgitation] trials) in which patients with functional MR and severe LV enlargement (LV end-diastolic diameter >65 mm) were treated with GDMT and the Carillon device versus GDMT alone. Key outcomes of this analysis were changes over 1 year of follow-up in mitral valve and LV echocardiographic parameters, functional outcome, quality of life, mortality, and heart failure hospitalization (HFH). RESULTS: A total of 95 patients (67 in the Carillon group, 28 in the GDMT group) with severe LV enlargement were included. In the Carillon group, all mitral valve and LV morphology parameters were significantly improved at 1 year. Regurgitant volume decreased by 12 ml (p < 0.001), MR grade decreased by 0.6 U (p < 0.001), LV end-diastolic volume decreased by 25 cm3 (p = 0.005), and LV end-systolic volume decreased by 21 cm3 (p = 0.01). Significant functional improvement differences were also noted between the Carillon group and the GDMT group including an improvement of Kansas City Cardiomyopathy Questionnaire score (15 ± 4 vs. 6 ± 6; p = 0.03). The incidence of HFH was 29.9% versus 50.0% and the cumulative rate of HFH was 0.43 versus 0.75 (p < 0.001). CONCLUSIONS: In patients with functional MR and severe LV enlargement, the Carillon device improved mitral valve function, LV morphology, and functional outcome compared with patients receiving GDMT only. Preoperative LV dimension should not be a limiting factor when evaluating patient eligibility or anticipated response to therapy with the Carillon device.


Assuntos
Insuficiência Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Qualidade de Vida
4.
J Am Coll Cardiol ; 77(3): 229-239, 2021 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-33478646

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is a frequent disease with a progressive increase in mortality as disease severity increases. Transcatheter therapies for treatment of TR may offer a safe and effective alternative to surgery in this high-risk population. OBJECTIVES: The purpose of this report was to study the 1-year outcomes with the TriClip transcatheter tricuspid valve repair system, including repair durability, clinical benefit and safety. METHODS: The TRILUMINATE trial (n = 85) is an international, prospective, single arm, multicenter study investigating safety and performance of the TriClip Tricuspid Valve Repair System in patients with moderate or greater TR. Echocardiographic assessment was performed by a core laboratory. RESULTS: At 1 year, TR was reduced to moderate or less in 71% of subjects compared with 8% at baseline (p < 0.0001). Patients experienced significant clinical improvements in New York Heart Association (NYHA) functional class I/II (31% to 83%, p < 0.0001), 6-minute walk test (272.3 ± 15.6 to 303.2 ± 15.6 meters, p = 0.0023) and Kansas City Cardiomyopathy Questionnaire (KCCQ) score (improvement of 20 ± 2.61 points, p < 0.0001). Significant reverse right ventricular remodeling was observed in terms of size and function. The overall major adverse event rate and all-cause mortality were both 7.1% at 1 year. CONCLUSION: Transcatheter tricuspid valve repair using the TriClip device was found to be safe and effective in patients with moderate or greater TR. The repair itself was durable at reducing TR at 1 year and was associated with a sustained and marked clinical benefit with low mortality after 1 year in a fragile population that was at high surgical risk. (TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR; NCT03227757).


Assuntos
Procedimentos Endovasculares/instrumentação , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Humanos , Masculino , Estudos Prospectivos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Remodelação Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA