Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
JACC Clin Electrophysiol ; 10(7 Pt 1): 1367-1376, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38752963

RESUMO

BACKGROUND: Pulmonary vein isolation is an effective treatment for atrial fibrillation (AF). Cryoballoon ablation using the Arctic Front cryoballoon (Medtronic) was found to be superior to antiarrhythmic drug treatment. Recently, a novel cryoballoon system was introduced (PolarX, Boston Scientific). OBJECTIVES: The purpose of this study was to compare the efficacy and safety of the 2 cryoballoons in a randomized controlled trial. METHODS: Patients with symptomatic paroxysmal AF were enrolled in 2 centers and randomized 1:1 to pulmonary vein isolation using the PolarX or the Arctic Front cryoballoon. All patients received an implantable cardiac monitor. The primary endpoint was first recurrence of atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia [AT]) between days 91 and 365. Procedural safety was assessed by a composite of tamponade, phrenic nerve palsy lasting >24 hours, vascular complications, stroke/transient ischemic attack, atrioesophageal fistula or death up to 30 days. RESULTS: A total of 201 patients were enrolled. At 1 year, recurrence of atrial tachyarrhythmia had occurred in 41 of 99 patients (41.6%) assigned to the PolarX group and in 48 of 102 patients (47.1%) assigned to the Arctic Front group (HR: 0.85 [95% CI: 0.56-1.30]; P = 0.03 for noninferiority; P = 0.46 for superiority). The safety endpoint occurred in 5 patients (5%) in the PolarX group (n = 5 phrenic nerve palsies lasting >24 hours), whereas no safety endpoints occurred in the Arctic Front group (P = 0.03). CONCLUSIONS: In this randomized controlled trial using implantable cardiac monitors for continuous rhythm monitoring, the novel PolarX cryoballoon was noninferior compared with the Arctic Front cryoballoon regarding efficacy. However, the PolarX balloon resulted in significantly more phrenic nerve palsies. (Comparison of PolarX and the Arctic Front Cryoballoons for PVI in Patients With Symptomatic Paroxysmal AF [COMPARE-CRYO]; NCT04704986).


Assuntos
Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Criocirurgia/métodos , Criocirurgia/instrumentação , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/cirurgia , Resultado do Tratamento , Recidiva , Nervo Frênico/lesões
2.
JACC Clin Electrophysiol ; 10(7 Pt 1): 1353-1364, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38819347

RESUMO

BACKGROUND: Catheter ablation for atrial fibrillation (AF) including pulmonary vein isolation and possibly further substrate ablation is the most common electrophysiological procedure. Severe complications are uncommon, but their detailed assessment in a large worldwide cohort is lacking. OBJECTIVES: The aim of this study was to determine the incidence of periprocedural severe complications and to provide a detailed characterization of the diagnostic evaluation and management of these complications in patients undergoing AF ablation. METHODS: Individual patient data were collected from 23 centers worldwide. Limited data were collected for all patients who underwent catheter ablation, and an expanded series of data points were collected for patients who experienced severe complications during periprocedural follow-up. Incidence, predictors, patient characteristics, management details, and overall outcomes of patients who experienced ablation-related complications were investigated. RESULTS: Data were collected from 23 participating centers at which 33,879 procedures were performed (median age 63 years, 30% women, 71% radiofrequency ablations). The incidence of severe complications (n = 271) was low (tamponade 6.8‰, stroke 0.97‰, cardiac arrest 0.41‰, esophageal fistula 0.21‰, and death 0.21‰). Age, female sex, a dilated left atrium, procedure duration, and the use of radiofrequency energy were independently associated with the composite endpoint of all severe complications. Among patients experiencing tamponade, 13% required cardiac surgery. Ninety-three percent of patients with complications were discharged directly home after a median length of stay of 5 days (Q1-Q3: 3-7 days). CONCLUSIONS: This large worldwide collaborative study highlighted that tamponade, stroke, cardiac arrest, esophageal fistula, and death are rare after AF ablation. Older age, female sex, procedure duration, a dilated left atrium, and the use of radiofrequency energy were associated with severe complications in this multinational cohort. One in 8 patients with tamponade required cardiac surgery.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Complicações Pós-Operatórias , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Idoso , Complicações Pós-Operatórias/epidemiologia , Incidência , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/etiologia , Acidente Vascular Cerebral/epidemiologia , Fístula Esofágica/epidemiologia , Fístula Esofágica/etiologia
3.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38607938

RESUMO

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Sistema de Registros , Reoperação , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Idoso , Fatores de Tempo , Suíça/epidemiologia , Fatores de Risco , Resultado do Tratamento , Estudos Prospectivos
4.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37944133

RESUMO

AIMS: Pulmonary vein isolation (PVI) plays a central role in the interventional treatment of atrial fibrillation (AF). Uncertainties remain about the durability of ablation lesions from different energy sources. We aimed to systematically review the durability of ablation lesions associated with various PVI-techniques using different energy sources for the treatment of AF. METHODS AND RESULTS: Structured systematic database search for articles published between January 2010 and January 2023 reporting PVI-lesion durability as evaluated in the overall cohort through repeat invasive remapping during follow-up. Studies evaluating only a proportion of the initial cohort in redo procedures were excluded. A total of 19 studies investigating 1050 patients (mean age 60 years, 31% women, time to remap 2-7 months) were included. In a pooled analysis, 99.7% of the PVs and 99.4% of patients were successfully ablated at baseline and 75.5% of the PVs remained isolated and 51% of the patients had all PVs persistently isolated at follow-up across all energy sources. In a pooled analysis of the percentages of PVs durably isolated during follow-up, the estimates of RFA were the lowest of all energy sources at 71% (95% CI 69-73, 11 studies), but comparable with cryoballoon (79%, 95%CI 74-83, 3 studies). Higher durability percentages were reported in PVs ablated with laser-balloon (84%, 95%CI 78-89, one study) and PFA (87%, 95%CI 84-90, 2 studies). CONCLUSION: We observed no significant difference in the durability of the ablation lesions of the four evaluated energies after adjusting for procedural and baseline populational characteristics.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fatores de Tempo , Resultado do Tratamento , Recidiva
5.
Radiat Oncol ; 18(1): 185, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37941012

RESUMO

BACKGROUND: Stereotactic arrhythmia radioablation (STAR) is delivered with a planning target volume (PTV) prescription dose of 25 Gy, mostly to the surrounding 75-85% isodose line. This means that the average and maximum dose received by the target is less than 35 Gy, which is the minimum threshold required to create a homogenous transmural fibrosis. Similar to catheter ablation, the primary objective of STAR should be transmural fibrosis to prevent heterogenous intracardiac conduction velocities and the occurrence of sustained ventricular arrhythmias (sVA) caused by reentry. We hypothesize that the current dose prescription used in STAR is inadequate for the long-term prevention of sVA and that a significant increase in dose is necessary to induce transmural scar formation. OBJECTIVE: A single arm, multi-center, phase II, dose escalation prospective clinical trial employing the i3 + 3 design is being conducted to examine the safety of a radiation dose-escalation strategy aimed at inducing transmural scar formation. The ultimate objective of this trial is to decrease the likelihood of sVA recurrence in patients at risk. METHODS: Patients with ischemic or non-ischemic cardiomyopathy and recurrent sVA, with an ICD and history of ≥ 1 catheter ablation for sVA will be included. This is a prospective, multicenter, one-arm, dose-escalation trial utilizing the i3 + 3 design, a modified 3 + 3 specifically created to overcome limitations in traditional dose-finding studies. A total of 15 patients will be recruited. The trial aims to escalate the ITV dose from 27.0 Gy to an ITV prescription dose-equivalent level of maximum 35.1 Gy by keeping the PTV prescription dose constant at 25 Gy while increasing the dose to the target (i.e. the VT substrate without PTV margin) by step-wise reduction of the prescribing isodose line (85% down to 65%). The primary outcome of this trial is safety measured by registered radiation associated adverse events (AE) up to 90 days after study intervention including radiation associated serious adverse events graded as at least 4 or 5 according to CTCAE v5, radiation pneumonitis or pericarditis requiring hospitalization and decrease in LVEF ≥ 10% as assessed by echocardiography or cardiac MRI at 90 days after STAR. The sample size was determined assuming an acceptable primary outcome event rate of 20%. Secondary outcomes include sVA burden at 6 months after STAR, time to first sVA recurrence, reduction in appropriate ICD therapies, the need for escalation of antiarrhythmic drugs, non-radiation associated safety and patient reported outcome measures such as SF-36 and EQ5D. DISCUSSION: DEFT-STAR is an innovative prospective phase II trial that aims to evaluate the optimal radiation dose for STAR in patients with therapy-refractory sVA. The trial has obtained IRB approval and focuses on determining the safe and effective radiation dose to be employed in the STAR procedure. TRIAL REGISTRATION: NCT05594368.


Assuntos
Radiocirurgia , Taquicardia Ventricular , Humanos , Estudos Prospectivos , Cicatriz/etiologia , Cicatriz/cirurgia , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Coração
6.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38036293

RESUMO

AIMS: Pulsed-field ablation (PFA) has emerged as a novel treatment technology for patients with atrial fibrillation (AF). Cryoballoon (CB) is the most frequently used single shot technology. A direct comparison to a novel CB system is lacking. We aimed to compare pulmonary vein isolation (PVI) using PFA vs. a novel CB system regarding efficiency, safety, myocardial injury, and outcomes. METHODS AND RESULTS: One hundred and eighty-one consecutive patients underwent PVI and were included (age 64 ± 9.7 years, ejection fraction 0.58 ± 0.09, left atrial size 40 ± 6.4 mm, paroxysmal AF 64%). 106 patients (59%) underwent PFA (FARAPULSE, Boston Scientific) and 75 patients (41%) underwent CB ablation (PolarX, Boston Scientific). The median procedure time, left atrial dwell time and fluoroscopic time were similar between the PFA and the CB group with 55 [interquartile range (IQR) 43-64] min vs. 58 (IQR 48-69) min (P < 0.087), 38 (30-49) min vs. 37 (31-48) min, (P = 0.871), and 11 (IQR 9.3-14) min vs. 11 (IQR 8.7-16) min, (P < 0.81), respectively. Three procedural complications were observed in the PFA group (two tamponades, one temporary ST elevation) and three complications in the CB group (3× reversible phrenic nerve palsies). During the median follow-up of 404 days (IQR 208-560), AF recurrence was similar in the PFA group and the CB group with 24 vs. 30%, P = 0.406. CONCLUSION: Procedural characteristics were very similar between PFA and CB in regard to procedure duration fluoroscopy time and complications. Atrial fibrillation free survival did not differ between the PFA and CB groups.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
7.
Contemp Clin Trials ; 134: 107341, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37722483

RESUMO

INTRODUCTION: Single-shot devices are increasingly used for pulmonary vein isolation (PVI) in atrial fibrillation (AF). The Arctic Front cryoballoon (Medtronic) is the most frequently used single-shot technology. A recently developed novel cryoballoon has been introduced (PolarX, Boston Scientific) with the aim to address limitations of the Arctic Front system. METHODS: COMPARE CRYO is a multicentre, randomized, controlled trial with blinded endpoint adjudication by an independent clinical events committee. A total of 200 patients with paroxysmal AF undergoing their first PVI are randomized 1:1 between PolarX cryoballoon ablation and Arctic Front cryoballoon ablation. Continuous monitoring during follow-up is performed using an implantable cardiac monitor (ICM) in all patients. The primary endpoint is time to first recurrence of any atrial tachyarrhythmia (AF, atrial flutter, and/or atrial tachycardia) ≥ 120 s between days 91 and 365 post ablation as detected on the (ICM). Procedural safety is assessed by a composite of cardiac tamponade, persistent phrenic nerve palsy >24 h, vascular complications requiring intervention, stroke/transient ischemic attack, atrioesophageal fistula or death occurring during or up to 30 days after the procedure. Key secondary endpoints include (1) procedure and fluoroscopy times, (2) AF burden, (3) proportion of patients with recurrence in the blanking period, (4) proportion of patients undergoing repeat ablation, and (5) quality of life changes at 12 months compared to baseline. CONCLUSION: COMPARE CRYO will compare the efficacy and safety of the novel PolarX cryoballoon and the standard-of-practice Arctic Front cryoballoon for first PVI performed in patients with symptomatic paroxysmal AF. TRIAL REGISTRATION: (ClinicalTrials.gov ID: NCT04704986).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Veias Pulmonares/cirurgia , Qualidade de Vida , Criocirurgia/métodos , Ablação por Cateter/métodos , Recidiva , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
8.
ESC Heart Fail ; 10(4): 2386-2394, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37218391

RESUMO

AIMS: Tachycardia-induced cardiomyopathy (TCM) represents a partially reversible type of cardiomyopathy (CM) that is often underdiagnosed and cardiac chamber remodelling in TCM remains incompletely understood. We aim to explore differences in the dimensions of the left ventricle and functional recovery in patients with TCM compared with patients with other forms of CM. METHODS AND RESULTS: We identified patients with reduced ejection fraction (≤50%) and/or atrial fibrillation or flutter with a left ventricular ejection fraction that improved from baseline (≥15% in left ventricular ejection fraction at follow-up or normalization of cardiac function with at least 10% improvement). Patients were then divided into two groups: (A) TCM patients and (B) patients with other forms of CM (controls). Two hundred thirty-eight patients were included (31% female, 70 years median age), 127 patients had TCM, and 111 had other forms of CM. Patients with TCM did not significantly improve indexed left ventricular volume (LVEDVI) after treatment (60 [45, 84] mL/m2 versus 56 [45, 70] mL/m2 , P = ns) compared with controls (67 [54, 81] mL/m2 versus 52 [42, 69] mL/m2 , P < 0.001). Patients with TCM patients had significantly worse fractional shortening at baseline than controls (15.5 [12, 23] vs. 20 [13, 30], P = 0.01) and higher indexed left atrial volume (LAVI) at baseline than controls (48 [37, 58] vs. 41 [33, 51], P = 0.01) that remained dilated at follow-up (follow-up LAVI 41 [33, 52] mL/m2 ). Good predictors of TCM were: normal LVEDVI (LVEDVI < 58 mL/m2 (M) and < 52 mL/m2 (F)) (odds ratio [OR] 5.2; 95% confidence interval [CI] 2.2-13.3, P < 0.001), fractional shortening < 30% (OR 3.5; 95% CI 1.4-9.2, P = 0.009), LAVI >40 mL/m2 (OR 3.4; 95% CI 1.6-7.3, P = 0.001) and normal wall thickness left ventricle (OR 3.2; 95% CI 1.4-7.8, P = 0.008). 54% of patients with TCM demonstrated diastolic dysfunction at follow-up, without differences from controls (54% vs. 43%, P = ns). 21% of patients with TCM showed persistent heart failure symptoms at follow-up compared with 4.5% of controls, P = 0.004. CONCLUSIONS: TCM patients have a specific pattern of functional recovery with persistent remodelling of the left atria and left ventricle. Several echocardiographic parameters might help identify TCM before treatment.


Assuntos
Cardiomiopatias , Função Ventricular Esquerda , Humanos , Feminino , Masculino , Volume Sistólico , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Ecocardiografia/métodos , Taquicardia
9.
Eur Heart J ; 44(27): 2458-2469, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37062040

RESUMO

AIMS: Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. METHODS AND RESULTS: This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. CONCLUSION: Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Humanos , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Resultado do Tratamento , Incidência , Fatores de Risco , Fístula Esofágica/epidemiologia , Fístula Esofágica/etiologia , Fístula Esofágica/diagnóstico , Prognóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
10.
J Interv Card Electrophysiol ; 66(9): 2047-2054, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37014482

RESUMO

BACKGROUND: Superimposition of farfield (FF) and nearfield (NF) bipolar voltage electrograms (BVE) complicates the confirmation of pulmonary vein (PV) isolation after catheter ablation of atrial fibrillation. Our aim was to develop an automatic algorithm based on a single-beat analysis to discriminate PV NF from atrial FF BVE from a circular mapping catheter during the cryoballoon PV isolation. METHODS: During freezing cycles in cryoablation PVI, local NF and distant FF signals were recorded, identified and labelled. BVEs were classified using four different machine learning algorithms based on four frequency domain (high-frequency power (PHF), low-frequency power (PLF), relative high power band, PHF ratio of neighbouring electrodes) and two time domain features (amplitude (Vmax), slew rate). The algorithm-based classification was compared to the true identification gained during the PVI and to a classification by cardiac electrophysiologists. RESULTS: We included 335 BVEs from 57 consecutive patients. Using a single feature, PHF with a cut-off at 150 Hz showed the best overall accuracy for classification (79.4%). By combining PHF with Vmax, overall accuracy was improved to 82.7% with a specificity of 89% and a sensitivity of 77%. The overall accuracy was highest for the right inferior PV (96.6%) and lowest for the left superior PV (76.9%). The algorithm showed comparable accuracy to the classification by the EP specialists. CONCLUSIONS: An automated farfield-nearfield discrimination based on two simple features from a single-beat BVE is feasible with a high specificity and comparable accuracy to the assessment by experienced cardiac electrophysiologists.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Eletrocardiografia , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Algoritmos , Resultado do Tratamento
11.
Europace ; 24(12): 1926-1932, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-35727739

RESUMO

AIMS: The aim of the study was to compare the 1-year efficacy and safety of a novel cryoballoon (NCB) ablation system (POLARx; Boston Scientific) for pulmonary vein isolation (PVI) compared with the standard cryoballoon (SCB) system (Arctic Front, Medtronic). METHODS AND RESULTS: Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB at two centres were included. We report 1-year efficacy after 12 months, short-term safety and hospitalizations within the blanking period, and predictors for AF recurrence. In case of repeat procedures, pulmonary vein (PV) reconnection patterns were characterized. Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 39 ± 13 mL/m2, paroxysmal AF in 64%) were studied. After a single procedure and a follow-up of 12 months, 68% in the NCB group and 70% in the SCB group showed no recurrence of AF/atrial tachycardias (P = 0.422). One patient in the NCB group suffered a periprocedural stroke with full recovery. There were no differences regarding hospitalizations during follow-up between the groups. PV reconnection observed during 12 repeat procedures (4 NCB, 8 SCB) pattern was comparable between the groups with more reconnections in the right-sided compared with the left-sided PVs. CONCLUSION: In this multicentre study comparing two currently available cryoballoon ablation systems for PVI, no differences were observed in the efficacy and safety during a follow-up of 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
13.
ESC Heart Fail ; 9(4): 2703-2712, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35438261

RESUMO

AIMS: New-onset atrial fibrillation (NOAF) is the most common complication after cardiac surgery, occurring in 25-50% of patients. It is associated with post-operative stroke, increased mortality, prolonged hospital length of stay, and higher treatment costs. Previous small observational studies have identified the left atrium as a source of the electrical rotors and foci maintaining NOAF, but confirmation by a large prospective clinical study is still missing. The aim of the proposed study is to investigate whether the source of NOAF lies in the left atrium. The correct identification of NOAF-maintaining structures in cardiac surgical patients might offer potential therapeutic targets for prophylactic perioperative ablation strategies. METHODS AND RESULTS: This is a prospective single-centre observational study of patients developing NOAF after cardiac surgery. The primary outcome is the description of NOAF-maintaining structures within the atria. Key secondary outcomes include overall mortality, intensive care unit length of stay, hospital-ventilator-free days, and proportion of persistent NOAF. In NOAF patients, the non-invasive electrophysiological mapping will be conducted using a 252-electrode electrocardiogram vest. After mapping, a low-dose computed tomography scan of the chest will be performed to integrate the electrophysiological mapping results into a 3D picture of the heart. The study will include approximately 570 patients, of whom 30% (n = 170) are expected to develop NOAF. Sample size calculation revealed that 157 NOAF patients are necessary to assess the primary outcome. Patients will be tracked for a total of 5 years. CONCLUSIONS: This is the largest prospective study to date describing the electrophysiological mechanisms of NOAF using non-invasive mapping.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Fibrilação Atrial/complicações , Fibrilação Atrial/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Eletrocardiografia , Humanos , Estudos Observacionais como Assunto , Estudos Prospectivos , Fatores de Risco
14.
J Interv Card Electrophysiol ; 64(2): 409-416, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34319493

RESUMO

PURPOSE: The aim was to report procedural and technical differences of a novel cryoballoon (NCB) ablation catheter for pulmonary vein isolation (PVI) compared to the standard cryoballoon (SCB) catheter. METHODS: Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB were included. Procedural parameters, technical differences, acute efficacy, and safety are reported. RESULTS: Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 40 ± 6 ml/m2) were studied. With the NCB, 156 of 158 PVs (99%) were isolated compared to isolation of 159 of 159 PVs (100%) with the SCB. The median number of freezes in the NCB and the SCB group was 6 (IQR 5-8) and 5 (IQR 4-7), respectively (p = 0.051), with 73% and 71% of the PVs isolated with a single freeze, respectively. Nadir temperature and temperature at isolation were - 59 ± 6 °C and - 45 ± 17 °C in the NCB group and - 46 ± 7 °C and - 32 ± 23 °C in the SCB group, respectively (both p < 0.001) with no difference in time to isolation (TTI). Procedural differences were observed for the total procedure time (84 ± 29 min in the NCB group and 65 ± 17 min in the SCB group, p = 0.003). There was a peri-procedural stroke in one patient in the NCB group. Differences in catheter design were observed that may account for the differences in temperature recordings and ice cap formation. CONCLUSIONS: Acute efficacy and TTI were similar with the NCB compared to the SCB. Measured temperatures were lower with the NCB, most likely due to differences in catheter design.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/cirurgia , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
16.
Eur J Prev Cardiol ; 28(6): 624-630, 2021 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-33611402

RESUMO

AIMS: To develop and externally validate a risk score for all-cause hospital admissions in patients with atrial fibrillation. METHODS AND RESULTS: We used a prospective cohort of 2387 patients with established atrial fibrillation as derivation cohort. Independent risk factors were selected from a broad range of variables using the least absolute shrinkage and selection operator method fit to a Cox model. The risk score was validated in a separate prospective cohort of 1300 atrial fibrillation patients. The incidence of all-cause hospital admission was 19.1 per 100 person-years in the derivation cohort and it was 26.1 per 100 person-years in the validation cohort. The most important predictors for admission were age (75-79 years: adjusted hazard ratio (aHR), 1.34; 95% confidence interval (CI), 1.01-1.78; 80-84 years: aHR, 1.50; 95% CI, 1.11-2.03; ≥85 years: aHR, 1.88; 95% CI, 1.36-2.62), prior pulmonary vein isolation (aHR, 0.72; 95% CI, 0.58-0.88), hypertension (aHR, 1.16; 95% CI, 0.99-1.36), diabetes (aHR, 1.38; 95% CI, 1.17-1.62), coronary heart disease (aHR, 1.17; 95% CI, 1.02-1.36), prior stroke/transient ischaemic attack (aHR, 1.26; 95% CI, 1.18-1.47), heart failure (aHR, 1.19; 95% CI, 1.03-1.39), peripheral artery disease (aHR, 1.35; 95% CI, 1.08-1.67), cancer (aHR, 1.33; 95% CI, 1.12-1.57), renal failure (aHR, 1.17; 95% CI, 0.99-1.37) and previous falls (aHR, 1.40; 95% CI, 1.13-1.74). A risk score with these variables was well calibrated, and achieved a C-index of 0.64 in the derivation and 0.59 in the validation cohort. CONCLUSIONS: Multiple risk factors were associated with hospital admissions in atrial fibrillation patients. This prediction tool selects high-risk patients who may benefit from preventive interventions.

17.
Swiss Med Wkly ; 150: w20343, 2020 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-33035354

RESUMO

INTRODUCTION: Sudden cardiac death caused by malignant arrhythmia can be prevented by the use of defibrillators. Although the wearable cardioverter defibrillator (WCD) can prevent such an event, its role in clinical practice is ill defined. We investigated the use of the WCD in Switzerland with emphasis on prescription rate, therapy adherence and treatment rate. MATERIALS AND METHODS: The Swiss WCD Registry is a retrospective observational registry including patients using a WCD. Patients were included from the first WCD use in Switzerland until February 2018. Baseline characteristics and data on WCD usage were examined for the total study population, and separately for each hospital. RESULTS: From 1 December 2011 to 18 February 2018, a total of 456 patients (67.1% of all WCDs prescribed in Switzerland and 81.1% of all prescribed in the participating hospitals) were included in the registry. Up to 2017 there was a yearly increase in the number of prescribed WCDs to a maximum of 271 prescriptions per year. The mean age of patients was 57 years (± 14), 81 (17.8%) were female and mean left ventricular ejection fraction (EF) was 32% (± 13). The most common indications for WCD use were new-onset ischaemic cardiomyopathy (ICM) with EF ≤35% (206 patients, 45.2%), new-onset nonischaemic cardiomyopathy (NICM) with EF ≤35% (115 patients, 25.2%), unknown arrhythmic risk (83 patients, 18.2%), bridging to implantable cardioverter-defibrillator implantation or heart transplant (37 patients, 8.1%) and congenital/inherited heart disease (15 patients, 3.3%). Median wear duration was 58 days (interquartile range [IQR] 31–94) with a median average daily wear time of 22.6 hours (IQR 20–23.2). Seventeen appropriate therapies from the WCD were delivered in the whole population (treatment rate: 3.7%) to a total of 12 patients (2.6% of all patients). The most common underlying heart disease in patients with a treatment was ICM (13/17, 76.5%). There were no inappropriate treatments. CONCLUSION: The use of WCDs has increased in Switzerland over the years for a variety of indications. There is high therapy adherence to the WCD, and a treatment rate comparable to previously published registry data.  .


Assuntos
Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Suíça , Função Ventricular Esquerda
18.
J Am Heart Assoc ; 9(15): e016075, 2020 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-32750290

RESUMO

Background Impaired heart rate variability (HRV) is associated with increased mortality in sinus rhythm. However, HRV has not been systematically assessed in patients with atrial fibrillation (AF). We hypothesized that parameters of HRV may be predictive of cardiovascular death in patients with AF. Methods and Results From the multicenter prospective Swiss-AF (Swiss Atrial Fibrillation) Cohort Study, we enrolled 1922 patients who were in sinus rhythm or AF. Resting ECG recordings of 5-minute duration were obtained at baseline. Standard parameters of HRV (HRV triangular index, SD of the normal-to-normal intervals, square root of the mean squared differences of successive normal-to-normal intervals and mean heart rate) were calculated. During follow-up, an end point committee adjudicated each cause of death. During a mean follow-up time of 2.6±1.0 years, 143 (7.4%) patients died; 92 deaths were attributable to cardiovascular reasons. In a Cox regression model including multiple covariates (age, sex, body mass index, smoking status, history of diabetes mellitus, history of hypertension, history of stroke/transient ischemic attack, history of myocardial infarction, antiarrhythmic drugs including ß blockers, oral anticoagulation), a decreased HRV index ≤ median (14.29), but not other HRV parameters, was associated with an increase in the risk of cardiovascular death (hazard ratio, 1.7; 95% CI, 1.1-2.6; P=0.01) and all-cause death (hazard ratio, 1.42; 95% CI, 1.02-1.98; P=0.04). Conclusions The HRV index measured in a single 5-minute ECG recording in a cohort of patients with AF is an independent predictor of cardiovascular mortality. HRV analysis in patients with AF might be a valuable tool for further risk stratification to guide patient management. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT02105844.


Assuntos
Fibrilação Atrial/mortalidade , Doenças Cardiovasculares/mortalidade , Frequência Cardíaca , Idoso , Fibrilação Atrial/fisiopatologia , Doenças Cardiovasculares/fisiopatologia , Eletrocardiografia , Eletrocardiografia Ambulatorial , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco
19.
J Interv Card Electrophysiol ; 57(1): 77-85, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31912448

RESUMO

BACKGROUND: Atrial fibrillation recurrence (AFR) is common after pulmonary vein isolation (PVI), and the rate does not differ between radiofrequency (RF) and cryoballoon (CB) ablation. The aim of this study was to assess the impact of the ablation modality used at the index PVI on the outcome after redo PVI in patients with paroxysmal AF. METHODS: In this prospective, single-center, non-randomized study, consecutive patients with paroxysmal AF who have undergone the index PVI with either RF ablation (RF group) or 2nd-generation CB (CB group) were included. The primary endpoint was freedom from recurrence of atrial arrhythmia lasting > 30 s. RESULTS: A total of 105 patients undergoing redo PVI for paroxysmal AF were included (median age 61 years; 24% female; left ventricular ejection fraction (LVEF) 57 ± 8%; left atrial volume index (LAVI) 34 ± 11 mm). Index PVI was done either with focal RF (n = 81) or with CB (n = 24) and redo PVI only with focal RF. Total procedure time (139 vs. 113 min, p = 0.10) and RF delivery time (1017 vs. 870 s, p = 0.33) of the redo PVI were not significantly different. After a median follow-up of 371 (185-470) days, there were no differences between the RF and CB groups regarding the AFR rate after the second PVI (24 vs. 23%, p = 0.89). The Kaplan-Meier analysis showed no difference between the groups regarding AFR freedom time (p = 0.81). In multivariable logistic regression, only coronary artery disease was identified as an independent long-term predictor of AFR (OR 4.15, 95% CI 1.17-14.71, p = 0.027). CONCLUSIONS: The ablation modality used at the index PVI has no impact on long-term outcome after redo PVI in patients with paroxysmal AF.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Prospectivos , Recidiva , Reoperação
20.
Lancet ; 394(10206): 1344-1351, 2019 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-31488371

RESUMO

BACKGROUND: A small proportion of patients undergoing primary prophylactic implantation of implantable cardioverter defibrillators (ICDs) experiences malignant arrhythmias. We postulated that periodic repolarisation dynamics, a novel marker of sympathetic-activity-associated repolarisation instability, could be used to identify electrically vulnerable patients who would benefit from prophylactic implantation of ICDs by way of a reduction in mortality. METHODS: We did a prespecified substudy of EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD), a prospective, investigator-initiated, non-randomised, controlled cohort study done at 44 centres in 15 EU countries. Patients aged 18 years or older with ischaemic or non-ischaemic cardiomyopathy and reduced left ventricular ejection fraction (≤35%) were eligible for inclusion if they met guideline-based criteria for primary prophylactic implantation of ICDs. Periodic repolarisation dynamics from 24-h Holter recordings were assessed blindly in patients the day before ICD implantation or on the day of study enrolment in patients who were conservatively managed. The primary endpoint was all-cause mortality. Propensity scoring and multivariable models were used to assess the interaction between periodic repolarisation dynamics and the treatment effect of ICDs on mortality. FINDINGS: Between May 12, 2014, and Sept 7, 2018, 1371 patients were enrolled in our study. 968 of these patients underwent ICD implantation, and 403 were treated conservatively. During follow-up (median 2·7 years [IQR 2·0-3·3] in the ICD group and 1·2 years [0·8-2·7] in the control group), 138 (14%) patients died in the ICD group and 64 (16%) patients died in the control group. We noted a 43% reduction in mortality in the ICD group compared with the control group (adjusted hazard ratio [HR] 0·57 [95% CI 0·41-0·79]; p=0·0008). Periodic repolarisation dynamics significantly predicted the treatment effect of ICDs on mortality (adjusted p=0·0307). The mortality benefits associated with ICD implantation were greater in patients with periodic repolarisation dynamics of 7·5 deg or higher (n=199; adjusted HR 0·25 [95% CI 0·13-0·47] for the ICD group vs the control group; p<0·0001) than in those with periodic repolarisation dynamics less than 7·5 deg (n=1166; adjusted HR 0·69 [95% CI 0·47-1·00]; p=0·0492; pinteraction=0·0056). The number needed to treat was 18·3 (95% CI 10·6-4895·3) in patients with periodic repolarisation dynamics less than 7·5 deg and 3·1 (2·6-4·8) in those with periodic repolarisation dynamics of 7·5 deg or higher. INTERPRETATION: Periodic repolarisation dynamics predict mortality reductions associated with prophylactic implantation of ICDs in contemporarily treated patients with ischaemic or non-ischaemic cardiomyopathy. Periodic repolarisation dynamics could help to guide treatment decisions about prophylactic ICD implantation. FUNDING: The European Community's 7th Framework Programme.


Assuntos
Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/prevenção & controle , Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica , Idoso , Cardiomiopatias/complicações , Cardiomiopatias/mortalidade , Estudos de Coortes , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA