Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Biomed Phys Eng Express ; 9(4)2023 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-37146592

RESUMO

Background. It is critical to monitor the radiation dose delivered to patients undergoing radiography and fluoroscopy to prevent both acute and potential long-term adverse health effects. Accurate estimation of organ doses is essential to ensuring that radiation dose is maintained As Low As Reasonably Achievable. We developed a graphical user interface-based organ dose calculation tool for pediatric and adult patients undergoing radiography and fluoroscopy examinations.Methods. Our dose calculator follows the four sequential steps. First, the calculator obtains input parameters related to patient age and gender, and x-ray source data. Second, the program creates an input file describing the anatomy and material composition of a phantom, x-ray source, and organ dose scorers for Monte Carlo radiation transport using the user input parameters. Third, a built-in Geant4 module was developed to import the input file and to calculate organ absorbed doses and skeletal fluences through Monte Carlo radiation transport. Lastly, active marrow and endosteum doses are derived from the skeletal fluences and effective dose is calculated from the organ and tissue doses. Following benchmarking with MCNP6, we conducted some benchmarking calculations calculated organ doses for an illustrative cardeiac interventional fluoroscopy and compared the results with those from an existing dose calculator, PCXMC.Results. The graphical user interface-based program was entitled National Cancer Institute dosimetry system for Radiography and Fluoroscopy (NCIRF). Organ doses calculated from NCIRF showed an excellent agreement with those from MCNP6 in the simulation of an illustrative fluoroscopy exam. In the cardiac interventional fluoroscopy exam of the adult male and female phantoms, the lungs received relatively greater doses than any other organs. PCXMC based on stylistic phantoms overall overestimated major organ doses calculated from NCIRF by up to 3.7-fold (active bone marrow).Conclusion. We developed an organ dose calculation tool for pediatric and adult patients undergoing radiography and fluoroscopy examinations. NCIRF could substantially increase the accuracy and efficiency of organ dose estimation in radiography and fluoroscopy exams.


Assuntos
Radiometria , Adulto , Humanos , Masculino , Criança , Feminino , Doses de Radiação , Radiografia , Radiometria/métodos , Fluoroscopia , Simulação por Computador
2.
World Neurosurg ; 171: e440-e446, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36528322

RESUMO

OBJECTIVE: In long thoracolumbar deformity surgery, accurate screw positioning is critical for spinal stability. We assessed pedicle and pelvic screw accuracy and radiation exposure in patients undergoing long thoracolumbar deformity fusion surgery (≥4 levels) involving 3-dimensional fluoroscopy (O-Arm/Stealth) navigation. METHODS: In this retrospective single-center cohort study, all patients aged >18 years who underwent fusion in 2016-2018 were reviewed. O-Arm images were assessed for screw accuracy. Effective radiation doses were calculated. The primary outcome was pedicle screw accuracy (Heary grade). Secondary outcomes were pelvic fixation screw accuracy, radiation exposure, and screw-related perioperative and postoperative complications or revision surgery within 3 years. RESULTS: Of 1477 pedicle screws placed in 91 patients (mean 16.41 ± 5.6 screws/patient), 1208 pedicle screws (81.8%) could be evaluated by 3-dimensional imaging after placement. Heary Grade I placement was achieved in 1150 screws (95.2%), Grade II in 47 (3.9%), Grade III in 10 (0.82%), Grade IV in 1 (0.08%), and Grade V in 0; Grade III-V were replaced intraoperatively. One of 60 (1.6%) sacroiliac screws placed showed medial cortical breach and was replaced. The average O-Arm-related effective dose was 29.54 ± 14.29 mSv and effective dose/spin was 8.25 ± 2.65 mSv. No postoperative neurological worsening, vascular injuries, or revision surgeries for screw misplacement were recorded. CONCLUSIONS: With effective radiation doses similar to those in interventional neuroendovascular procedures, the use of O-Arm in multilevel complex deformity surgery resulted in high screw accuracy, no need for surgical revision because of screw malposition, less additional imaging, and no radiation exposure for the surgical team.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Adulto , Cirurgia Assistida por Computador/métodos , Estudos de Coortes , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Fluoroscopia/métodos , Fusão Vertebral/métodos , Vértebras Lombares/cirurgia
3.
Cells ; 9(10)2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-33076401

RESUMO

Accurate dosimetry and determination of the biological effectiveness of boron neutron capture therapy (BNCT) is challenging because of the mix of different types and energies of radiation at the cellular and subcellular levels. In this paper, we present a computational, multiscale system of models to better assess the relative biological effectiveness (RBE) and compound biological effectiveness (CBE) of several neutron sources as applied to BNCT using boronophenylalanine (BPA) and a potential monoclonal antibody (mAb) that targets HER-2-positive cells with Trastuzumab. The multiscale model is tested against published in vitro and in vivo measurements of cell survival with and without boron. The combined dosimetric and radiobiological model includes an analytical formulation that accounts for the type of neutron source, the tissue- or cancer-specific dose-response characteristics, and the microdistribution of boron. Tests of the model against results from published experiments with and without boron show good agreement between modeled and experimentally determined cell survival for neutrons alone and in combination with boron. The system of models developed in this work is potentially useful as an aid for the optimization and individualization of BNCT for HER-2-positive cancers, as well as other cancers, that can be targeted with mAb or a conventional BPA compound.


Assuntos
Terapia por Captura de Nêutron de Boro , Sobrevivência Celular/efeitos da radiação , Neoplasias/radioterapia , Radioterapia Conformacional , Eficiência Biológica Relativa , Animais , Compostos de Boro/uso terapêutico , Linhagem Celular , Terapia Combinada , Relação Dose-Resposta à Radiação , Humanos , Transferência Linear de Energia , Método de Monte Carlo , Fenilalanina/análogos & derivados , Fenilalanina/uso terapêutico , Radiometria , Receptor ErbB-2/imunologia , Trastuzumab/uso terapêutico
4.
Phys Med Biol ; 60(21): 8249-74, 2015 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-26449929

RESUMO

To account for particle interactions in the extracellular (physical) environment, information from the cell-level Monte Carlo damage simulation (MCDS) for DNA double strand break (DSB) induction has been integrated into the general purpose Monte Carlo N-particle (MCNP) radiation transport code system. The effort to integrate these models is motivated by the need for a computationally efficient model to accurately predict particle relative biological effectiveness (RBE) in cell cultures and in vivo. To illustrate the approach and highlight the impact of the larger scale physical environment (e.g. establishing charged particle equilibrium), we examined the RBE for DSB induction (RBEDSB) of x-rays, (137)Cs γ-rays, neutrons and light ions relative to γ-rays from (60)Co in monolayer cell cultures at various depths in water. Under normoxic conditions, we found that (137)Cs γ-rays are about 1.7% more effective at creating DSB than γ-rays from (60)Co (RBEDSB = 1.017) whereas 60-250 kV x-rays are 1.1 to 1.25 times more efficient at creating DSB than (60)Co. Under anoxic conditions, kV x-rays may have an RBEDSB up to 1.51 times as large as (60)Co γ-rays. Fission neutrons passing through monolayer cell cultures have an RBEDSB that ranges from 2.6 to 3.0 in normoxic cells, but may be as large as 9.93 for anoxic cells. For proton pencil beams, Monte Carlo simulations suggest an RBEDSB of about 1.2 at the tip of the Bragg peak and up to 1.6 a few mm beyond the Bragg peak. Bragg peak RBEDSB increases with decreasing oxygen concentration, which may create opportunities to apply proton dose painting to help address tumor hypoxia. Modeling of the particle RBE for DSB induction across multiple physical and biological scales has the potential to aid in the interpretation of laboratory experiments and provide useful information to advance the safety and effectiveness of hadron therapy in the treatment of cancer.


Assuntos
Simulação por Computador , Quebras de DNA de Cadeia Dupla/efeitos da radiação , Raios gama , Método de Monte Carlo , Nêutrons , Fótons , Eficiência Biológica Relativa , Humanos , Prótons , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA