Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Phys Imaging Radiat Oncol ; 27: 100456, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37720465

RESUMO

Background and purpose: Radiotherapy (RT) treatment planning is as a standard based on a computed tomography (CT) scan obtained at the planning stage (pCT), while most of the decisions whether to treat by RT are based on diagnostic CT scans (dCT). Bone metastases (BM) are the most common palliative RT target. The objective of this study was to investigate if a palliative RT treatment plan of BMs could be made based on a dCT with sufficient accuracy and safety, without sacrificing any treatment quality. Materials and methods: A retrospective study with 60 BMs of 8 anatomical sites was performed. RT planning was performed using intensity-modulated radiation therapy/volumetric modulated arc therapy techniques in dCT and transferred to pCT. The dose of clinical target volumes (CTVs), D(CTVV95%, V50%), were compared between plans for dCT and pCT. Patient setup was investigated in cone-beam CT scans. Results: The differences of D(CTVV95%, V50%) between dCT and pCT plans were the lowest in the pelvis (1.0%, 1.1%), lumbar spine (0.6%, 0.7%) and thoracic spine (0.7%, 2.1%), while the differences were higher in cervical spine (3.7%, 1.9%), long bones (2.3%, 0.8%), and costae (1.6%, 1.4%). The patient set-up was acceptable for 100% of the pelvic and lumbar, for 92% of thoracic spine cases, and for <80% of cases in other sites. Conclusion: This study showed the feasibility of using dCT images in palliative RT planning of BMs in thoracic, lumbar spine and pelvic sites, indicating the potential suitability of this strategy for clinical use.

2.
J Appl Physiol (1985) ; 134(4): 995-1003, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36927142

RESUMO

We analyzed the fractal dimension (Df) of lung gas and blood distribution imaged with synchrotron radiation K-edge subtraction (KES), in six anesthetized adult New Zealand White rabbits. KES imaging was performed in upright position during stable Xe gas (64% in O2) inhalation and iodine infusion (Iomeron, 350 mg/mL), respectively, at baseline and after induced bronchoconstriction by aerosolized methacholine (125 mg/mL, 90 s) and bronchodilator (salbutamol, 10 mg/mL, 90 s) inhalation, at two axial image levels. Lung Xe and iodine images were segmented, and maps of regional lung gas and blood fractions were computed. The Df of lung gas (DfXe) and blood (DfIodine) distribution was computed based on a log-log plot of variation coefficient as a function of region volume. DfXe decreased significantly during bronchoconstriction (P < 0.0001), and remained low after salbutamol. DfIodine depended on the axial image level (P < 0.0001), but did not change with bronchoconstriction. DfXe was significantly associated with arterial [Formula: see text] (R = 0.67, P = 0.002), and negatively associated with [Formula: see text] (R = -0.62, P = 0.006), respiratory resistance (R = -0.58, P = 0.011), and elastance (R = -0.55, P = 0.023). These data demonstrate the reduced Df of gas distribution during acute bronchoconstriction, and the association of this parameter with physiologically meaningful variables. This finding suggests a decreased complexity and space-filling properties of lung ventilation during bronchoconstriction, and could serve as a functional imaging biomarker in obstructive airway diseases.NEW & NOTEWORTHY Here, we used an energy-subtractive imaging technique to assess the fractal dimension (Df) of lung gas and blood distribution and the effect of acute bronchoconstriction. We found that Df of gas significantly decreases in bronchoconstriction. Conversely, Df of blood exhibits gravity-dependent changes only, and is not affected by acute bronchoconstriction. Our data show that the fractal dimension of lung gas detects the emergence of clustered rather than scattered loss of ventilatory units during bronchoconstriction.


Assuntos
Asma , Iodo , Animais , Coelhos , Broncoconstrição , Síncrotrons , Fractais , Ventilação Pulmonar/fisiologia , Pulmão , Albuterol/farmacologia , Iodo/farmacologia
3.
Radiat Prot Dosimetry ; 188(2): 181-190, 2020 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-31838516

RESUMO

In contemporary interventional cardiology, for typical elderly patients, the most severe radiation-related harm to patients can be considered to come from skin exposures. In this paper, maximum local skin doses in cardiological procedures are explored with Gafchromic film dosimetry. Film and reader calibrations and reading were performed at the Secondary Standards Dosimetry Laboratory of the Radiation and Nuclear Safety Authority (STUK), and data were gathered from seven hospitals in Finland. As alert levels for early transient erythema, 200 Gycm2 kerma area product (KAP) and 2000 mGy air kerma levels for transcatheter aortic valve implantations (TAVI) procedures are proposed. The largest doses were measured in TAVI (4158.8 mGy) and percutaneous coronary interventions (PCI) (941.68 mGy). Accuracies of the GE DoseWatch and Siemens CareMonitor skin dose estimates were reasonable, but more results are needed to reliably assess and validate the tools' capabilities and reliabilities. Uncertainty of the Gafchromic dosimetry was estimated as 9.1% for a calibration with seven data points and 19.3% for a calibration with five data points.


Assuntos
Cardiologia , Intervenção Coronária Percutânea , Idoso , Finlândia , Fluoroscopia , Humanos , Doses de Radiação , Radiografia Intervencionista , Pele
4.
Radiat Prot Dosimetry ; 185(4): 483-493, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-30989216

RESUMO

The amount of interventional procedures such as percutaneous coronary intervention (PCI), transcatheter aortic valve implantation (TAVI), pacemaker implantation (PI) and ablations has increased within the previous decade. Simultaneously, novel fluoroscopy mainframes enable lower radiation doses for patients and operators. Therefore, there is a need to update the existing diagnostic reference levels (DRLs) and propose new ones for common or recently introduced procedures. We sought to assess patient radiation doses in interventional cardiology in a large sample from seven hospitals across Finland between 2014 and 2016. Data were used to set updated national DRLs for coronary angiographies (kerma-air product (KAP) 30 Gycm2) and PCIs (KAP 75 cm2), and novel levels for PIs (KAP 3.5 Gycm2), atrial fibrillation ablation procedures (KAP 25 Gycm2) and TAVI (KAP 90 Gycm2). Tentative KAP values were set for implantations of cardiac resynchronization therapy devices (CRT, KAP 22 Gycm2), electrophysiological treatment of atrioventricular nodal re-entry tachycardia (6 Gycm2) and atrial flutter procedures (KAP 16 Gycm2). The values for TAVI and CRT device implantation are published for the first time on national level. Dose from image acquisition (cine) constitutes the major part of the total dose in coronary and atrial fibrillation ablation procedures. For TAVI, patient weight is a good predictor of patient dose.


Assuntos
Cardiologia/normas , Doses de Radiação , Radiografia Intervencionista/métodos , Radiologia Intervencionista/normas , Radiometria , Idoso , Valva Aórtica/cirurgia , Nó Atrioventricular/patologia , Cardiologia/métodos , Angiografia Coronária , Eletrofisiologia , Feminino , Finlândia , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Radiologia Intervencionista/métodos , Valores de Referência , Taquicardia/patologia
5.
Am J Physiol Lung Cell Mol Physiol ; 299(2): L242-51, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20543004

RESUMO

Despite the prevalence of active smoking in asthmatics, data on the short-term effect of acute mainstream tobacco smoke exposure on airway responsiveness are very scarce. The aim of this study was to assess the immediate effect of acute exposure to mainstream cigarette smoke on airway reactivity to subsequent nonspecific and allergenic challenges in healthy control (n = 5) and ovalbumin-sensitized rabbits (n = 6). We combined low-frequency forced oscillations and synchrotron radiation CT imaging to differentiate central airway and peripheral airway and lung parenchymal components of the response to airway provocation. Acute exposure to smoke generated by four successive cigarettes (CS) strongly inhibited the central airway response to subsequent IV methacholine (MCh) challenge. In the sensitized animals, although the response to ovalbumin was also inhibited in the central airways, mainstream CS did not blunt the peripheral airway response in this group. In additional groups of experiments, exposure to HEPA-filtered CS (n = 6) similarly inhibited the MCh response, whereas CO (10,000 ppm for 4 min, n = 6) or nitric oxide inhalation instead of CS (240 ppm, 4 x 7 min, n = 5) failed to blunt nonspecific airway responsiveness. Pretreatment with alpha-chymotrypsin to inhibit endogenous VIP before CS exposure had no effect (n = 4). Based on these observations, the gas phase of mainstream cigarette smoke may contain one or more short-term inhibitory components acting primarily on central airways and inhibiting the response to both specific and nonspecific airway provocation, but not on the lung periphery where both lung mechanical parameters, and synchrotron-imaging derived parameters, showed large changes in response to allergen challenge in sensitized animals.


Assuntos
Pulmão/imunologia , Fumar/efeitos adversos , Administração por Inalação , Alérgenos/farmacologia , Animais , Monóxido de Carbono/efeitos adversos , Quimotripsina/farmacologia , Pulmão/diagnóstico por imagem , Pulmão/efeitos dos fármacos , Pulmão/fisiologia , Masculino , Cloreto de Metacolina/farmacologia , Ovalbumina/imunologia , Coelhos , Tomografia Computadorizada por Raios X
6.
Am J Respir Crit Care Med ; 180(4): 296-303, 2009 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-19483115

RESUMO

RATIONALE: Methacholine (Mch) is routinely used to assess bronchial hyperreactivity; however, little is known about the differences in the lung response pattern between this provocation and that observed with ovalbumin (Ova) after allergic sensitization. OBJECTIVES: To compare (1) the central versus peripheral effects of Mch and Ova within the lung by combining measurements of airway and tissue mechanics with synchrotron radiation (SR) imaging, and (2) to assess the extent to which mechanical and imaging parameters are correlated. METHODS: We used the low-frequency forced oscillation technique and SR imaging in control (n = 12) and ovalbumin-sensitized (n = 13) rabbits, at baseline, during intravenous Mch infusion (2.5 microg/kg/min, 5.0 microg/kg/min, or 10.0 microg/kg/min), after recovery from Mch, and after intravenous Ova injection (2.0 mg). We compared intravenous Mch challenge with inhaled Mch (125 mg/ml, 90 s) in a separate group of control animals (n = 5). MEASUREMENTS AND MAIN RESULTS: Airway conductance and tissue elastance were measured by low-frequency forced oscillation technique. The central airway cross-sectional area, the ventilated alveolar area, and the heterogeneity of specific ventilation were quantified by SR imaging. Mch infusion induced constriction predominantly in the central airways, whereas Ova provocation affected mainly the peripheral airways, leading to severe ventilation heterogeneities in sensitized animals. Mch inhalation affected both conducting and peripheral airways. The correlations between airway conductance and central airway cross-sectional area (R = 0.71) and between tissue elastance and ventilated alveolar area (R = -0.72) were strong. CONCLUSIONS: The pattern of lung response caused by intravenous Mch and Ova are fundamentally different. Although inhaled Mch induces a heterogeneous lung response similar to that observed with intravenous allergen, these similar patterns are due to different mechanisms.


Assuntos
Alérgenos , Hiper-Reatividade Brônquica/fisiopatologia , Testes de Provocação Brônquica/métodos , Broncoconstritores , Modelos Animais de Doenças , Processamento de Imagem Assistida por Computador , Cloreto de Metacolina , Oscilometria , Ovalbumina , Mecânica Respiratória/fisiologia , Síncrotrons , Tomografia Computadorizada por Raios X , Administração por Inalação , Resistência das Vias Respiratórias/fisiologia , Alérgenos/imunologia , Animais , Relação Dose-Resposta a Droga , Infusões Intravenosas , Pulmão/fisiopatologia , Complacência Pulmonar/fisiologia , Ovalbumina/imunologia , Ventilação Pulmonar/fisiologia , Coelhos
7.
Radiother Oncol ; 93(1): 80-6, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19433339

RESUMO

BACKGROUND AND PURPOSE: Isocentric treatment technique is a standard method in photon radiotherapy with the primary advantage of requiring only a single patient set-up procedure for multiple fields. However, in electron treatments the size of the standard applicators does not generally allow to use an isocentric treatment technique. In this work we have modified and dosimetrically tested electron applicators for isocentric treatments in combination with photons. An isocentric treatment technique with photons and electrons for postmastectomy radiation therapy (PMRT) has been developed with special emphasis on improving the dose uniformity in the field gap area. MATERIALS AND METHODS: Standard electron applicators of two Varian Clinac 2100CD linear accelerators were shortened by 10cm allowing isocentric treatments of 90cm

Assuntos
Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Interpretação de Imagem Radiográfica Assistida por Computador , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Mama/patologia , Estudos de Coortes , Relação Dose-Resposta à Radiação , Elétrons/uso terapêutico , Feminino , Humanos , Mastectomia/métodos , Aceleradores de Partículas , Fótons/uso terapêutico , Lesões por Radiação/prevenção & controle , Dosagem Radioterapêutica , Radioterapia Adjuvante , Medição de Risco , Resultado do Tratamento
8.
Eur J Radiol ; 68(3 Suppl): S78-83, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18606518

RESUMO

There is a growing interest in imaging techniques as non-invasive means of quantitatively measuring regional lung structure and function. Abnormalities in lung ventilation due to alterations in airway function such as those observed in asthma and COPD are highly heterogeneous, and experimental methods to study this heterogeneity are crucial for better understanding of disease mechanisms and drug targeting strategies. In severe obstructive diseases requiring mechanical ventilation, the optimal ventilatory strategy to achieve recruitment of poorly ventilated lung zones remains a matter of considerable debate. We have used synchrotron radiation computed tomography (SRCT) for the in vivo study of regional lung ventilation and airway function. This imaging technique allows direct quantification of stable Xenon (Xe) gas used as an inhaled contrast agent using K-edge subtraction imaging. Dynamics of Xe wash-in can be used to calculate quantitative maps of regional specific lung ventilation. More recently, the development of Spiral-CT has allowed the acquisition of 3D images of the pulmonary bronchial tree and airspaces. This technique gives access to quantitative measurements of regional lung volume, ventilation, and mechanical properties. Examples of application in an experimental model of allergic asthma and in imaging lung recruitment as a function of mechanical ventilation parameters will be presented. The future orientations of this technique will be discussed.


Assuntos
Pneumopatias/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Refratometria/métodos , Síncrotrons , Tomografia por Raios X/métodos , Algoritmos , Humanos , Imageamento Tridimensional/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA