Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Anesth Analg ; 134(4): 773-780, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35051952

RESUMO

BACKGROUND: Error grid analysis was recently proposed to compare blood pressure obtained by 2 measurement methods. This study aimed to compare continuous noninvasive blood pressure (CNBP) with invasive blood pressure (IBP) using the error grid analysis and investigate the confounding risk factors attributable to the differences between CNBP and IBP. METHODS: Sixty adult patients undergoing general anesthesia were prospectively enrolled. Simultaneous comparative data regarding CNBP and IBP were collected. The Bland-Altman analysis was conducted to compare CNBP and IBP for systolic blood pressure (SBP) and mean blood pressure (MBP; acceptable accuracy: mean bias <5 mm Hg; standard deviation <8 mm Hg). The clinical relevance of the discrepancies between CNBP and IBP was evaluated by the error grid analysis, which classifies the differences into 5 zones from "no risk" (A) to "dangerous risk" (E). Additionally, an ordinal logistic regression analysis was performed to evaluate the relationship between the risk zones for MBP, classified by the error grid analysis and covariates of interest. RESULTS: A total of 10,663 pairs of CNBP/IBP were finally analyzed. The Bland-Altman analysis showed an acceptable accuracy with a bias of -3.3 ± 5.6 mm Hg for MBP but a poor accuracy with a bias of 5.4 ± 10.5 mm Hg for SBP. The error grid analysis showed the proportions of zones A to E as 96.7%, 3.2%, 0.1%, 0%, and 0% for SBP, respectively, and 72.0%, 27.9%, 0.1%, 0%, and 0% for MBP, respectively. The finger cuff missed 23.9% of epochs when SBP <90 mm Hg and 55.3% of epochs when MBP <65 mm Hg. The ordinal logistic regression analysis revealed that older age (adjusted odds ratio for decade: 1.54, 95% confidence interval [CI], 1.15-2.08; P = .004) and length of time from the initiation of finger cuff inflation (adjusted odds ratio for 60 minutes: 1.40, 95% CI, 1.13-1.73; P = .002) were significant factors of being in a more dangerous zone of the error grid. CONCLUSIONS: The error grid analysis revealed the larger clinical discrepancy between CNBP and IBP in MBP compared with that in SBP. Old age and longer finger cuff inflation time were significant factors of being in a more dangerous zone of the error grid, which could affect the hemodynamic management during surgery.


Assuntos
Determinação da Pressão Arterial , Monitores de Pressão Arterial , Adulto , Pressão Arterial/fisiologia , Pressão Sanguínea , Determinação da Pressão Arterial/métodos , Dedos , Humanos
2.
J Cardiothorac Vasc Anesth ; 36(8 Pt A): 2344-2351, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35094928

RESUMO

OBJECTIVE: Postoperative pulmonary complications (PPC) remain a main issue after cardiac surgery. The objective was to report the incidence and identify risk factors of PPC after cardiac surgery. DESIGN: An international multicenter prospective study (42 international centers in 9 countries). PARTICIPANTS: A total of 707 adult patients who underwent cardiac surgery under cardiopulmonary bypass. INTERVENTIONS: None MEASUREMENTS AND MAIN RESULTS: During a study period of 2 weeks, the investigators included all patients in their respective centers and screened for PPCs. PPC was defined as the occurrence of at least 1 pulmonary complication among the following: atelectasis, pleural effusion, respiratory failure, respiratory infection, pneumothorax, bronchospasm, or aspiration pneumonitis. Among 676 analyzed patients, 373 patients presented with a PPC (55%). The presence of PPC was significantly associated with a longer intensive care length of stay and hospital length of stay. One hundred ninety (64%) patients were not intraoperatively ventilated during cardiopulmonary bypass. Ventilation settings were similar regarding tidal volume, respiratory rate, inspired oxygen. In the regression model, age, the Euroscore II, chronic obstructive pulmonary disease, preoxygenation modality, intraoperative positive end-expiratory pressure, the absence of pre- cardiopulmonary bypass ventilation, the absence of lung recruitment, and the neuromuscular blockade were associated with PPC occurrence. CONCLUSION: Both individual risk factors and ventilatory settings were shown to explain the high level of PPCs. These findings require further investigations to assess a bundle strategy for optimal ventilation strategy to decrease PPC incidence.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Pneumopatias , Complicações Pós-Operatórias , Adulto , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Pneumopatias/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos
3.
J Thorac Cardiovasc Surg ; 163(2): e137-e156, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-32414598

RESUMO

OBJECTIVES: We aimed to investigate the protective effect of remote ischemic preconditioning against spinal cord ischemia and find a clue to its mechanism by measuring glutamate concentrations in the spinal ventral horn. METHODS: Male Sprague-Dawley rats were divided into 5 groups (n = 6 in each group) as follows: sham; SCI (only spinal cord ischemia); RIPC/SCI (perform remote ischemic preconditioning before spinal cord ischemia); MK-801/RIPC/SCI (administer MK-801, N-methyl-D-aspartate receptor antagonist, before remote ischemic preconditioning); and MK-801/SCI (administer MK-801 without remote ischemic preconditioning). Remote ischemic preconditioning was achieved by brief limb ischemia 80 minutes before spinal cord ischemia. MK-801 (1 mg/kg, intravenous) was administered 60 minutes before remote ischemic preconditioning. The glutamate concentration in the ventral horn was measured by microdialysis for 130 minutes after spinal cord ischemia. Immunofluorescence was also performed to evaluate the expression of N-methyl-D-aspartate receptor 2B subunit in the ventral horn 130 minutes after spinal cord ischemia. RESULTS: The glutamate concentrations in the spinal cord ischemia group were significantly higher than in the sham group at all time points (P < .01). Remote ischemic preconditioning attenuated the spinal cord ischemia-induced glutamate increase. When MK-801 was preadministered before remote ischemic preconditioning, glutamate concentration was increased after spinal cord ischemia (P < .01). Immunofluorescence showed that remote ischemic preconditioning prevented the increase in the expression of N-methyl-D-aspartate receptor 2B subunit on the surface of motor neurons (P = .047). CONCLUSIONS: Our results showed that remote ischemic preconditioning prevented spinal cord ischemia-induced extracellular glutamate increase in ventral horn and suppressed N-methyl-D-aspartate receptor 2B subunit expression.


Assuntos
Maleato de Dizocilpina/farmacologia , Ácido Glutâmico/análise , Precondicionamento Isquêmico/métodos , Traumatismo por Reperfusão , Isquemia do Cordão Espinal , Medula Espinal/irrigação sanguínea , Animais , Células do Corno Anterior/metabolismo , Fármacos Neuroprotetores/farmacologia , Ratos , Ratos Sprague-Dawley , Receptores de N-Metil-D-Aspartato/antagonistas & inibidores , Traumatismo por Reperfusão/metabolismo , Traumatismo por Reperfusão/prevenção & controle , Isquemia do Cordão Espinal/metabolismo , Isquemia do Cordão Espinal/prevenção & controle , Resultado do Tratamento
4.
J Clin Monit Comput ; 36(4): 1069-1077, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34191254

RESUMO

Non-invasive methods to assess patients' fluid responsiveness during lung-protective ventilation are needed. We hypothesized changes in the corrected carotid flow time induced by the recruitment maneuver predict fluid responsiveness under general anesthesia. Thirty patients undergoing general anesthesia in the supine position were prospectively enrolled. The study protocol was conducted when the patient was hemodynamically stable during surgery. Flow time was measured on Doppler images of the common carotid artery. Carotid flow time, heart rate, stroke volume, stroke volume variation, and pulse pressure variation were recorded before and after a recruitment maneuver at a continuous airway pressure of 30 cmH2O for 30 s, and before and after volume expansion with 250 mL for 10 min. Patients were defined as fluid responders if the increase in stroke volume was > 10% after volume expansion. Twenty patients (67%) were fluid responders. All Doppler images for carotid flow time were obtained within 30 s. Changes in the corrected flow time accurately predicted fluid responsiveness (area under the curve: 0.82, 95% confidence interval [CI] 0.64-0.94, p = 0.002). The optimal threshold for changes in the corrected flow time was - 11.7% with a sensitivity of 95.0% (95% CI 75.1-99.9%) and a specificity of 80.0% (95% CI 44.4-97.5%). The gray-zone of changes in the corrected flow time was from - 25.1 to - 12.2% and included 12 patients (40%). Changes in the corrected carotid flow time were a useful, technically easy-to-perform, and non-invasive method to predict fluid responsiveness without a need for hemodynamic monitoring or arterial cannulation.


Assuntos
Hidratação , Hemodinâmica , Anestesia Geral , Pressão Sanguínea/fisiologia , Artérias Carótidas/diagnóstico por imagem , Hidratação/métodos , Hemodinâmica/fisiologia , Humanos , Respiração Artificial/métodos , Volume Sistólico/fisiologia
5.
J Thorac Cardiovasc Surg ; 164(6): e269-e283, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34090694

RESUMO

OBJECTIVE: This experimental study aimed to assess the efficacy of hydrogen gas inhalation against spinal cord ischemia-reperfusion injury and reveal its mechanism by measuring glutamate concentration in the ventral horn using an in vivo microdialysis method. METHODS: Male Sprague-Dawley rats were divided into the following 6 groups: sham, only spinal ischemia, 3% hydrogen gas (spinal ischemia + 3% hydrogen gas), 2% hydrogen gas (spinal ischemia + 2% hydrogen gas), 1% hydrogen gas (spinal ischemia + 1% hydrogen gas), and hydrogen gas dihydrokainate (spinal ischemia + dihydrokainate [selective inhibitor of glutamate transporter-1] + 3% hydrogen gas). Hydrogen gas inhalation was initiated 10 minutes before the ischemia. For the hydrogen gas dihydrokainate group, glutamate transporter-1 inhibitor was administered 20 minutes before the ischemia. Immunofluorescence was performed to assess the expression of glutamate transporter-1 in the ventral horn. RESULTS: The increase in extracellular glutamate induced by spinal ischemia was significantly suppressed by 3% hydrogen gas inhalation (P < .05). This effect was produced in increasing order: 1%, 2%, and 3%. Conversely, the preadministration of glutamate transporter-1 inhibitor diminished the suppression of spinal ischemia-induced glutamate increase observed during the inhalation of 3% hydrogen gas. Immunofluorescence indicated the expression of glutamate transporter-1 in the spinal ischemia group was significantly decreased compared with the sham group, which was attenuated by 3% hydrogen gas inhalation (P < .05). CONCLUSIONS: Our study demonstrated hydrogen gas inhalation exhibits a protective and concentration-dependent effect against spinal ischemic injury, and glutamate transporter-1 has an important role in the protective effects against spinal cord injury.


Assuntos
Traumatismo por Reperfusão , Isquemia do Cordão Espinal , Animais , Masculino , Ratos , Sistema X-AG de Transporte de Aminoácidos/metabolismo , Modelos Animais de Doenças , Glutamatos/metabolismo , Hidrogênio/farmacologia , Isquemia , Ratos Sprague-Dawley , Traumatismo por Reperfusão/prevenção & controle , Traumatismo por Reperfusão/metabolismo , Medula Espinal/metabolismo , Isquemia do Cordão Espinal/prevenção & controle , Isquemia do Cordão Espinal/metabolismo
6.
BMC Anesthesiol ; 21(1): 303, 2021 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-34856928

RESUMO

BACKGROUND: The present study aimed to evaluate the reliability of hemodynamic changes induced by lung recruitment maneuver (LRM) in predicting stroke volume (SV) increase after fluid loading (FL) in prone position. METHODS: Thirty patients undergoing spine surgery in prone position were enrolled. Lung-protective ventilation (tidal volume, 6-7 mL/kg; positive end-expiratory pressure, 5 cmH2O) was provided to all patients. LRM (30 cmH2O for 30 s) was performed. Hemodynamic variables including mean arterial pressure (MAP), heart rate, SV, SV variation (SVV), and pulse pressure variation (PPV) were simultaneously recorded before, during, and at 5 min after LRM and after FL (250 mL in 10 min). Receiver operating characteristic curves were generated to evaluate the predictability of SVV, PPV, and SV decrease by LRM (ΔSVLRM) for SV responders (SV increase after FL > 10%). The gray zone approach was applied for ΔSVLRM. RESULTS: Areas under the curve (AUCs) for ΔSVLRM, SVV, and PPV to predict SV responders were 0.778 (95% confidence interval: 0.590-0.909), 0.563 (0.371-0.743), and 0.502 (0.315-0.689), respectively. The optimal threshold for ΔSVLRM was 30% (sensitivity, 92.3%; specificity, 70.6%). With the gray zone approach, the inconclusive values ranged 25 to 75% for ΔSVLRM (including 50% of enrolled patients). CONCLUSION: In prone position, LRM-induced SV decrease predicted SV increase after FL with higher reliability than traditional dynamic indices. On the other hand, considering the relatively large gray zone in this study, future research is needed to further improve the clinical significance. TRIAL REGISTRATION: UMIN Clinical Trial Registry UMIN000027966 . Registered 28th June 2017.


Assuntos
Hidratação/métodos , Cuidados Intraoperatórios/métodos , Respiração com Pressão Positiva/métodos , Fenômenos Fisiológicos Respiratórios , Coluna Vertebral/cirurgia , Volume Sistólico/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Decúbito Ventral , Reprodutibilidade dos Testes
7.
Anesth Analg ; 133(1): 44-52, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33687175

RESUMO

BACKGROUND: We aimed to evaluate the ability of lung recruitment maneuver-induced hemodynamic changes to predict fluid responsiveness in patients undergoing lung-protective ventilation during one-lung ventilation (OLV). METHODS: Thirty patients undergoing thoracic surgery with OLV (tidal volume: 6 mL/kg of ideal body weight and positive end-expiratory pressure: 5 cm H2O) were enrolled. The study protocol began 30 minutes after starting OLV. Simultaneous recordings were performed for hemodynamic variables of heart rate, mean arterial pressure (MAP), stroke volume (SV), pulse pressure variation (PPV), and stroke volume variation (SVV) were recorded at 4 time points: before recruitment maneuver (continuous airway pressure: 30 cm H2O for 30 seconds), at the end of recruitment maneuver, and before and after volume loading (250 mL over 10 minutes). Patients were recognized as fluid responders if the increase in SV or MAP was >10%. Receiver operating characteristic curves for percent decrease in SV and MAP by recruitment maneuver (ΔSVRM and ΔMAPRM, respectively) were generated to evaluate the ability to discriminate fluid responders from nonresponders. The gray-zone approach was applied for ΔSVRM and ΔMAPRM. RESULTS: Of 30 patients, there were 17 SV-responders (57%) and 12 blood pressure (BP)-responders (40%). Area under the curve (AUC) for ΔSVRM to discriminate SV-responders from nonresponders was 0.84 (95% confidence interval [CI], 0.67-0.95; P < .001). The best threshold for ΔSVRM to discriminate the SV-responders was -23.7% (95% CI, -41.2 to -17.8; sensitivity, 76.5% [95% CI, 50.1-93.2]; specificity, 84.6% [95% CI, 54.6-98.1]). For BP-responders, AUC for ΔMAPRM was 0.80 (95% CI, 0.61-0.92, P < .001). The best threshold for ΔMAPRM was -17.3% (95% CI, -23.9 to -5.1; sensitivity, 75.0% [95% CI, 42.8-94.5]; specificity, 77.8% [95% CI, 52.4-93.6]). With the gray-zone approach, the inconclusive range of ΔSVRM for SV-responders was -40.1% to -13.8% including 13 (43%) patients, and that of ΔMAPRM was -23.9% to -5.1%, which included 16 (53%) patients. CONCLUSIONS: ΔSVRM and ΔMAPRM could predict hemodynamic responses after volume expansion during OLV.


Assuntos
Pressão Arterial/fisiologia , Hidratação/métodos , Hemodinâmica/fisiologia , Ventilação Monopulmonar/métodos , Volume Sistólico/fisiologia , Procedimentos Cirúrgicos Torácicos/métodos , Idoso , Feminino , Previsões , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Volume de Ventilação Pulmonar/fisiologia
8.
J Anesth ; 35(3): 378-383, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33502589

RESUMO

On Mar 11, 2020, the World Health Organization declared coronavirus disease (COVID-19), caused by severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), a pandemic. Because COVID-19 has a pre-symptomatic period of up to 2 weeks, SARS-CoV-2 infection has continued to spread. Some individuals with SARS-CoV-2 infection have a severe clinical course, while most individuals have mild or moderate symptoms. Because SARS-CoV-2 is transmitted via droplets and secretions, anesthesiologists have higher risks of infection, especially during airway management. Therefore, general anesthesia requiring airway management can be a challenging procedure for anesthesiologists. During the pandemic, many elective surgeries have been postponed or cancelled in most affected countries. Recently, the number of elective surgeries is gradually recovering from the effect of the COVID-19 pandemic, and hence, safe clinical practice and protocols to prevent SARS-CoV-2 transmission to medical staff should be established. This mini-review focuses on the preoperative assessment and decision with regard to scheduling surgery in elective and emergency cases during the COVID-19 pandemic. A standardized questionnaire and algorithm regarding COVID-19 should be used to assess surgical patients preoperatively as it increases the reproducibility and accuracy of the decision whether to proceed with surgery.


Assuntos
COVID-19 , Pandemias , Procedimentos Cirúrgicos Eletivos , Humanos , Reprodutibilidade dos Testes , SARS-CoV-2
9.
J Cardiothorac Vasc Anesth ; 35(6): 1782-1791, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33279380

RESUMO

OBJECTIVE: To assess the effect of systemic vascular resistance (SVR) on the reliability of the ClearSight system (Edwards Lifesciences, Irvine, CA) for measuring blood pressure (BP) and cardiac output (CO). DESIGN: Observational study. SETTING: University hospital. PARTICIPANTS: Twenty-five patients undergoing cardiac surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: BP, measured using ClearSight and an arterial line, and CO, measured using ClearSight and a pulmonary artery catheter, were recorded before (T1) and two minutes after phenylephrine or ephedrine administration. Bland-Altman analysis was used to compare BP and CO measurements at T1. A polar plot was used to assess trending abilities. Patients were divided into the following three groups according to the SVR index (SVRI) at T1: low (<1,200 dyne s/cm5/m2), normal (1,200-25,00 dyne s/cm5/m2), and high (>2,500 dyne s/cm5/m2). The bias in BP and CO was -4.8 ± 8.9 mmHg and 0.10 ± 0.81 L/min, respectively, which was correlated significantly with SVRI (p < 0.05). The percentage error in CO was 40.6%, which was lower in the normal SVRI group (33.3%) than the low and high groups (46.3% and 47.7%, respectively). The angular concordance rate was 96.3% and 95.4% for BP and 87.0% and 92.5% for CO after phenylephrine and ephedrine administration, respectively. There was a low tracking ability for CO changes after phenylephrine administration in the low-SVRI group (angular concordance rate 33.3%). CONCLUSION: The ClearSight system showed an acceptable accuracy in measuring BP and tracking BP changes in various SVR states; however, the accuracy of CO measurement and its trending ability in various SVR states was poor.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Monitorização Hemodinâmica , Débito Cardíaco , Humanos , Monitorização Intraoperatória , Reprodutibilidade dos Testes , Termodiluição , Resistência Vascular
10.
Br J Anaesth ; 125(6): 953-961, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33092805

RESUMO

BACKGROUND: Transthoracic oesophagectomy is associated with major morbidity and mortality, which may be reduced by goal-directed therapy (GDT). The aim of this multicentre, RCT was to evaluate the impact of intraoperative GDT on major morbidity and mortality in patients undergoing transthoracic oesophagectomy. METHODS: Adult patients undergoing transthoracic oesophagectomy were randomised to receive either minimally invasive intraoperative GDT (stroke volume variation <8%, plus systolic BP maintained >90 mm Hg by pressors as necessary) or haemodynamic management left to the discretion of attending senior anaesthetists (control group; systolic BP >90 mm Hg alone). The primary outcome was the incidence of death or major complications (reoperation for bleeding, anastomotic leakage, pneumonia, reintubation, >48 h ventilation). A Cox proportional hazard model was used to examine whether the effects of GDT on morbidity and mortality were independent of other potential confounders. RESULTS: A total of 232 patients (80.6% male; age range: 36-83 yr) were randomised to either GDT (n=115) or to the control group (n=117). After surgery, major morbidity and mortality were less frequent in 22/115 (19.1%) subjects randomised to GDT, compared with 41/117 (35.0%) subjects assigned to the control group {absolute risk reduction: 15.9% (95% confidence interval [CI]: 4.7-27.2%); P=0.006}. GDT was also associated with fewer episodes of atrial fibrillation (odds ratio [OR]: 0.18 [95% CI: 0.05-0.65]), respiratory failure (OR: 0.27 [95% CI: 0.09-0.83]), use of mini-tracheotomy (OR: 0.29 [95% CI: 0.10-0.81]), and readmission to ICU (OR: 0.09 [95% CI: 0.01-0.67]). GDT was independently associated with morbidity and mortality (hazard ratio: 0.51 [95% CI: 0.30-0.87]; P=0.013). CONCLUSIONS: Intraoperative GDT may reduce major morbidity and mortality, and shorten hospital stay, after transthoracic oesophagectomy. CLINICAL TRIAL REGISTRATION: UMIN000018705.


Assuntos
Esofagectomia/mortalidade , Hidratação/mortalidade , Hidratação/métodos , Cuidados Intraoperatórios/métodos , Complicações Pós-Operatórias/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Esofagectomia/métodos , Feminino , Humanos , Cuidados Intraoperatórios/mortalidade , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
11.
J Clin Monit Comput ; 34(1): 41-53, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30796642

RESUMO

This study aimed to compare the prognostic performance of the ratio of mixed and central venous-arterial CO2 tension difference to arterial-venous O2 content difference (Pv-aCO2/Ca-vO2 and Pcv-aCO2/Ca-cvO2, respectively) with that of the mixed and central venous-to-arterial carbon dioxide gradient (Pv-aCO2 and Pcv-aCO2, respectively) for adverse events after cardiac surgery. One hundred and ten patients undergoing cardiac surgery with cardiopulmonary bypass were enrolled. After catheter insertion, three blood samples were withdrawn simultaneously through arterial pressure, central venous, and pulmonary artery catheters, before and at the end of the operation, and preoperative and postoperative values were determined. The primary end-point was set as the incidence of postoperative major organ morbidity and mortality (MOMM). Receiver operating characteristic (ROC) curve and multivariate logistic regression analyses were performed to evaluate the prognostic reliability of Pv-aCO2, Pcv-aCO2, Pv-aCO2/Ca-vO2, and Pcv-aCO2/Ca-cvO2 for MOMM. MOMM events occurred in 25 patients (22.7%). ROC curve analysis revealed that both postoperative Pv-aCO2/Ca-vO2 and Pcv-aCO2/Ca-cvO2 were significant predictors of MOMM. However, postoperative Pv-aCO2 was the best predictor of MOMM (area under the curve [AUC]: 0.804; 95% confidence interval [CI] 0.688-0.921), at a 5.1-mmHg cut-off, sensitivity was 76.0%, and specificity was 74.1%. Multivariate analysis revealed that postoperative Pv-aCO2 was an independent predictor of MOMM (odds ratio [OR]: 1.42, 95% CI 1.01-2.00, p = 0.046) and prolonged ICU stay (OR: 1.45, 95% CI 1.05-2.01, p = 0.024). Pv-aCO2 at the end of cardiac surgery was a better predictor of postoperative complications than Pv-aCO2/Ca-vO2 and Pcv-aCO2/Ca-cvO2.


Assuntos
Artérias/metabolismo , Gasometria , Dióxido de Carbono/sangue , Cardiopatias/cirurgia , Veias/metabolismo , Idoso , Área Sob a Curva , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar , Feminino , Ventrículos do Coração , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Oxigênio/sangue , Período Pós-Operatório , Período Pré-Operatório , Prognóstico , Curva ROC , Reprodutibilidade dos Testes , Fatores de Risco , Choque Séptico/sangue , Resultado do Tratamento
12.
J Cardiothorac Vasc Anesth ; 33(1): 149-156, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30082129

RESUMO

OBJECTIVES: To assess whether a tissue Doppler imaging (TDI)-based parameter consisting of the sum of early diastolic velocities of the mitral annulus (Me') and tricuspid annulus (Te') can serve as a predictor of adverse outcomes after cardiac surgery. DESIGN: Prospective, observational study. SETTING: University hospital. PARTICIPANTS: The study comprised 100 patients undergoing cardiac surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: After anesthetic induction, transesophageal echocardiography was performed to obtain the values of the early transmitral flow velocity (E), Me', and Te'. The primary endpoint was the incidence of postoperative major organ morbidity and mortality (MOMM) events, including death, redo surgery, prolonged ventilation, stroke, sternal infection, and dialysis. Receiver operating characteristic and multivariate logistic analyses were used to examine the prognostic performance of TDI-based parameters for predicting MOMM incidence. The secondary endpoint was the incidence of death or rehospitalization for cardiovascular disease within 1 year post-discharge. TDI-based parameters were measured in 87 of the 100 patients enrolled. Me' plus Te' had better prognostic ability (area under the curve 0.771; threshold 13 cm/s; sensitivity 86.7%; specificity 64.9%) than that of Me' or E to Me' (E/Me')% and was an independent predictor of MOMM (odds ratio 0.45; 95% confidence interval 0.28-0.74, p = 0.001), whereas Me' was not. Lower Me' plus Te' (≤13 cm/s) was associated with a significantly higher incidence and earlier onset of cardiovascular events within 1 year post-discharge (p = 0.012). CONCLUSIONS: Compared with Me' and E/Me', which traditionally are used for assessing diastolic function, Me' plus Te' showed better prognostic ability for both short- and long-term outcomes of cardiac surgery.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Doenças das Valvas Cardíacas/cirurgia , Valva Mitral/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico , Valva Tricúspide/diagnóstico por imagem , Idoso , Diástole , Ecocardiografia Doppler/métodos , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Valva Mitral/cirurgia , Complicações Pós-Operatórias/fisiopatologia , Prognóstico , Estudos Prospectivos , Valva Tricúspide/cirurgia
13.
Medicine (Baltimore) ; 97(47): e12845, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30461602

RESUMO

BACKGROUND: Oxidative stress may be an integral determinant of surgical stress severity. We examined whether the preoperative level of derivatives of reactive oxygen metabolites (d-ROMs), an oxidative stress biomarker based on total hydroperoxides in circulating blood, is predictive of increased risk of delayed recovery and complications after surgery, as well as the effects of anesthesia management on postoperative recovery in light of oxidative stress. METHODS: Patients (American Society of Anesthesiologists physical status I-II) scheduled for a radical esophagectomy (n = 186) were randomly selected to receive inhalational sevoflurane (n = 94) or intravenous propofol (n = 92) anesthesia. Preoperative blood d-ROMs level, as well as pre-and postoperative plasma ferric-reducing ability, were analyzed to assess oxidative stress, with white blood cell (WBC) count, C-reactive protein (CRP) level, incidence of severe postoperative complications, and postoperative recovery process within 30 days after surgery also examined in a double-blind fashion. RESULTS: Postoperative normalization of WBC and CRP was extended in patients with elevated preoperative d-ROMs [WBC versus d-ROMs: correlation coefficient (r) = 0.58 P < .001; CRP versus d-ROMs: r = 0.46 P < .001]. Receiver operating characteristics analysis of d-ROMs in relation to incidence of severe postoperative complications revealed an optimum d-ROMs threshold value of 410 UCarr and that patients with ≥410 UCarr had a greater risk of complications as compared to those with lower values (odds ratio = 4.7). Plasma ferric-reducing ability was decreased by 61 ±â€Š185 mmol·l (P < .001) after surgery, demonstrating development of surgery-related oxidative stress, the magnitude of which was positively correlated with preoperative d-ROMs level (r = 0.16, P = .043). A comparison of the 2 anesthesia management protocols showed that patients who received propofol, an antioxidant anesthetic, had no postoperative decrease in ferric-reducing ability, lower incidence of severe postoperative complications (7 of 92 versus 18 of 94, P = .030, odds ratio = 0.35), and faster uneventful recovery time (WBC normalization days 7.1 ±â€Š5.2 versus 13.6 ±â€Š10.2, P < .001) as compared to those who received sevoflurane. CONCLUSIONS: Elevated preoperative blood d-ROMs predicts greater intraoperative oxidative stress and increased postoperative complications with prolonged recovery, thus is useful for identifying high-risk patients for delayed and complicated surgical recovery. Reduction of oxidative stress is vital for enhanced recovery, with control by antioxidants such as propofol a possible solution.


Assuntos
Anestésicos Inalatórios , Anestésicos Intravenosos , Esofagectomia/efeitos adversos , Estresse Oxidativo , Cuidados Pós-Operatórios , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/prevenção & controle , Espécies Reativas de Oxigênio/sangue , Idoso , Biomarcadores/sangue , Proteína C-Reativa/metabolismo , Método Duplo-Cego , Feminino , Humanos , Ferro/sangue , Contagem de Leucócitos , Masculino , Éteres Metílicos/administração & dosagem , Pessoa de Meia-Idade , Propofol/administração & dosagem , Fatores de Risco , Sevoflurano
14.
J Anesth ; 32(6): 822-830, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30267340

RESUMO

PURPOSE: This study aimed to investigate the efficacy of the ClearSight™ system (Edwards Lifesciences, Irvine, CA) for reducing the incidence of hypotension compared with the traditional oscillometric blood pressure monitoring in cesarean delivery under spinal anesthesia. METHODS: Forty patients undergoing cesarean delivery under spinal anesthesia were enrolled. The patients were randomly divided into two groups (Control and ClearSight groups). All patients received spinal anesthesia using 0.5% hyperbaric bupivacaine (11.5 mg) and fentanyl (10 µg). Blood pressure was managed with the same protocol using the ClearSight™ system (ClearSight group) and oscillometric blood pressure monitoring (Control group). Furthermore, we compared the accuracy of the ClearSight™ system with the traditional oscillometric monitoring for blood pressure measurement using Bland-Altman, four-quadrant plot, and polar plot analyses. RESULTS: The incidence of hypotension was significantly lower in the ClearSight group from induction to delivery (45% vs. 0%, p < 0.001) and to the end of surgery (50% vs. 20%, p = 0.049). Intraoperative nausea occurred more frequently in the Control group (45% vs. 10%, p = 0.012). The ClearSight™ system demonstrated acceptable accuracy with a bias of - 4.3 ± 11.7 mmHg throughout the procedure. Four-quadrant analysis revealed an excellent trending ability of the ClearSight™ system with a concordance rate of approximately 95%. In the polar plot analysis, the angular bias and concordance rate were - 13.5° ± 19.0° and 76.9%, respectively. CONCLUSIONS: The accuracy and trending ability of the ClearSight™ system for blood pressure measurement was clinically acceptable in cesarean delivery under spinal anesthesia, leading to reductions in maternal hypotension and nausea.


Assuntos
Raquianestesia/métodos , Determinação da Pressão Arterial/métodos , Cesárea/métodos , Hipotensão/epidemiologia , Adulto , Anestesia Obstétrica/efeitos adversos , Anestesia Obstétrica/métodos , Pressão Sanguínea , Bupivacaína/administração & dosagem , Feminino , Fentanila/administração & dosagem , Humanos , Gravidez
15.
J Clin Monit Comput ; 32(6): 1005-1013, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29511971

RESUMO

This study assessed the ability of a continuous non-invasive blood pressure (BP) monitoring system to reduce intra-anesthetic hemodynamic fluctuation compared with intermittent BP cuff measurement. Forty patients undergoing total knee arthroplasty under general anesthesia were enrolled and randomly divided into two groups (Control and CS group). BP management was performed using the same protocol with BP measured by intermittent BP cuff in the Control and that by continuous non-invasive BP monitoring in the CS group. We assessed the accuracy and precision of the continuous non-invasive BP monitoring compared with BP cuff measurement using Bland-Altman, four-quadrant plot, and polar-plot analyses. Additionally, the occurrence of hypotension and hypertention during general anesthesia was compared between the two groups. The continuous non-invasive BP monitoring showed excellent accuracy of - 1.1 ± 8.1 mmHg during surgery and an acceptable trending ability with a concordance rate of 95.1% according to the four-quadrant plot analysis and an angular concordance rate of 86.7% by polar-plot analysis. Hypotension was less common in the CS group during induction of anesthesia (p = 0.002) and surgery (p = 0.008). Hypertension occurred more frequently in the Control group during emergence from anesthesia (p = 0.037). The duration of hemodynamic stability (systolic BP 80-110% of baseline) intraoperatively was longer in the CS group than in the Control group (87.7 vs. 61.9%; p < 0.001). Accuracy and trending ability of the continuous non-invasive BP monitoring was clinically acceptable, and lead to hemodynamic stability and reduction of intra-anesthetic hypotension and hypertension intraoperatively.


Assuntos
Anestesia Geral/efeitos adversos , Determinação da Pressão Arterial/métodos , Monitorização Hemodinâmica/métodos , Monitorização Intraoperatória/métodos , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho , Determinação da Pressão Arterial/estatística & dados numéricos , Feminino , Monitorização Hemodinâmica/estatística & dados numéricos , Humanos , Hipertensão/etiologia , Hipertensão/fisiopatologia , Hipertensão/prevenção & controle , Hipotensão/etiologia , Hipotensão/fisiopatologia , Hipotensão/prevenção & controle , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/estatística & dados numéricos
16.
J Clin Monit Comput ; 32(3): 415-422, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28647806

RESUMO

This study aimed to assess the reliability of stroke volume variation (SVV) in predicting cardiac output (CO) decrease and hypotension during induction of general anesthesia. Forty-five patients undergoing abdominal surgery under general anesthesia were enrolled. Before induction of anesthesia, patients were required to maintain deep breathing (6-8 times/min), and pre-anesthetic SVV was measured for 1 min by electrical cardiometry. General anesthesia was induced with propofol, remifentanil, rocuronium, and sevoflurane. Study duration was defined from the start of fluid administration till 5 min after tracheal intubation. Blood pressure (BP) was measured every minute. Cardiac output was measured continuously by electrical cardiometry. Receiver operating characteristics (ROC) curves were made regarding the incidence of decreased CO (less than 70% of the baseline) and hypotension (mean BP <65 mmHg). The risk of developing decreased CO and hypotension was evaluated by multivariate logistic regression analysis. The time from the start of the procedure to onset of decreased CO was analyzed by the Kaplan-Meier method. The area under the ROC curve and optimal threshold value of pre-anesthetic SVV for predicting decreased CO and hypotension were 0.857 and 0.693. Patients with lower SVV exhibited a significantly slower onset and lower incidence of decreased CO than those with higher SVV (p = 0.003). Multivariate logistic regression analysis indicated high pre-anesthetic SVV as being an independent risk factor for decreased CO and hypotension (odds ratio, 1.43 and 1.16, respectively). In conclusions, pre-anesthetic SVV can predict incidence of decreased CO and hypotension during induction of general anesthesia.


Assuntos
Anestesia Geral/efeitos adversos , Monitorização Intraoperatória/métodos , Volume Sistólico , Procedimentos Cirúrgicos Operatórios/métodos , Idoso , Anestesiologia , Anestésicos/administração & dosagem , Pressão Sanguínea , Determinação da Pressão Arterial , Débito Cardíaco , Feminino , Hemodinâmica , Humanos , Hipotensão , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Curva ROC , Análise de Regressão , Reprodutibilidade dos Testes , Risco , Fatores de Tempo
17.
J Anesth ; 31(6): 878-884, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29071382

RESUMO

PURPOSE: Hypotension and decreased cardiac output (CO) are common adverse effects during anesthesia induction depending on the patient's pre-anesthetic cardiac condition. The aim of this study was to assess the ability of hydroxyethyl starch (HES) 130/0.4 to prevent hypotension and decreased CO during the induction of general anesthesia. METHODS: Ninety patients undergoing laparoscopic surgery were randomly divided into a HES group and a crystalloid group. Following the insertion of an intravenous line, fluid was administered to each patient at a rate of 25 ml/min using either crystalloid or HES 130/0.4. Five minutes after the initiation of fluid loading, anesthesia was induced using propofol (1.5 mg/kg), rocuronium (0.9 mg/kg), and remifentanil (0.3 mcg/kg/min). Tracheal intubation was performed 5 min after the induction of anesthesia. Following tracheal intubation, general anesthesia was maintained using remifentanil and sevoflurane. Non-invasive blood pressure (BP) level was measured at 1-min intervals and CO was measured continuously using electrical cardiometry from the start of fluid loading until 5 min after tracheal intubation. RESULTS: The number of patients with hypotension (systolic BP < 90 mmHg or 80% of baseline) was significantly lower in the HES group (p < 0.001) than in the crystalloid group. Patients in the HES group showed smaller CO decreases than did patients in the crystalloid group (p < 0.001). The Kaplan-Meier method showed a lower incidence and significantly slower onset of hypotension in the HES group (p = 0.009). Multivariate logistic regression models indicated that the use of HES is an independent factor for the prevention of both hypotension and decreased CO (below 85% of baseline; p < 0.005 for both). CONCLUSIONS: Co-loading using HES 130/0.4 prevented hypotension and decreased CO during general anesthesia induction.


Assuntos
Anestesia Geral/métodos , Derivados de Hidroxietil Amido/administração & dosagem , Hipotensão/prevenção & controle , Soluções Isotônicas/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral/efeitos adversos , Raquianestesia/métodos , Pressão Sanguínea/efeitos dos fármacos , Soluções Cristaloides , Feminino , Humanos , Hipotensão/etiologia , Masculino , Pessoa de Meia-Idade , Substitutos do Plasma/uso terapêutico
18.
J Anesth ; 30(3): 526-9, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26961821

RESUMO

The aim of this study was to assess the current practices of hemodynamic management in high-risk surgical patients among Japanese anesthesiologists. An invitation letter to the survey, which included 35 questions related to hemodynamic monitoring in high-risk surgery, was mailed to every hospital approved by the Japanese Society of Anesthesiologists (JSA) (1260 hospitals). Of the 692 JSA respondents, 573 completed the survey. Despite reporting a high rate of cardiac output (CO) and stroke volume variation (SVV) monitoring in JSA members (70 and 74 %, respectively), fluid goal-directed therapy was poorly implemented in high-risk surgery (7.4 %). Also, 47 % of the JSA respondents did not consistently perform CO optimization. SVV was more commonly used (76 %) as an indicator of volume expansion among JSA respondents, while central venous pressure was less frequently used (48 %). Despite a broader use of advanced hemodynamic monitoring, optimization of CO is still poorly protocolized and applied in Japan. The development of guidelines and protocols for hemodynamic management, including the establishment of strong evidence aimed at improving clinical outcomes, is needed to assist anesthesiologists in more universal adoption of perioperative CO optimization.


Assuntos
Anestesiologistas/estatística & dados numéricos , Anestesiologia/métodos , Hemodinâmica/fisiologia , Débito Cardíaco/fisiologia , Pressão Venosa Central/fisiologia , Humanos , Japão , Risco , Volume Sistólico/fisiologia , Inquéritos e Questionários
19.
J Cardiothorac Vasc Anesth ; 29(3): 656-62, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25440654

RESUMO

OBJECTIVES: The aims of this study were to compare cardiac output (CO) measured by the new fourth-generation FloTrac™/Vigileo™ system (Version 4.00) (COFVS) with that measured by a pulmonary artery catheter (COREF), and to investigate the ability of COFVS to track CO changes induced by increased peripheral resistance. DESIGN: Prospective study. SETTING: University Hospital. PARTICIPANTS: Twenty-three patients undergoing cardiac surgery. INTERVENTIONS: Phenylephrine (100 µg) was administered. MEASUREMENTS AND MAIN RESULTS: Hemodynamic variables, including CO(REF) and CO(FVS), were measured before and after phenylephrine administration. Bland-Altman analysis was used to assess the discrepancy between CO(REF) and CO(FVS). Four-quadrant plot and polar-plot analyses were utilized to evaluate the trending ability of CO(FVS) against CO(REF) after phenylephrine boluses. One hundred thirty-six hemodynamic interventions were performed. The bias shown by the Bland-Altman analysis was-0.66 L/min, and the percentage error was 55.4%. The bias was significantly correlated with the systemic vascular resistance index (SVRI) before phenylephrine administration (p<0.001, r(2) = 0.420). The concordance rate determined by four-quadrant plot analysis and the angular concordance rate calculated using polar-plot analysis were 87.0% and 83.0%, respectively. Additionally, this trending ability was not affected by SVRI state. CONCLUSIONS: The trending ability of the new fourth-generation FloTrac™/Vigileo™ system after increased vasomotor tone was greatly improved compared with previous versions; however, the discrepancy of the new system in CO measurement was not clinically acceptable, as in previous versions. For clinical application in critically ill patients, this vasomotor tone-dependent disagreement must be decreased.


Assuntos
Débito Cardíaco/fisiologia , Procedimentos Cirúrgicos Cardíacos/normas , Cateterismo de Swan-Ganz/normas , Monitorização Intraoperatória/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/métodos , Cateterismo de Swan-Ganz/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Estudos Prospectivos , Termodiluição/métodos , Termodiluição/normas
20.
J Cardiothorac Vasc Anesth ; 28(4): 943-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25107714

RESUMO

OBJECTIVE: To investigate the correlation between intraoperative body temperature and postoperative adverse effects in patients who underwent esophagectomy procedures. DESIGN: Retrospective cohort study. SETTING: University Hospital. PARTICIPANTS: One hundred twenty-one patients undergoing esophagectomy were enrolled. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Various perioperative and intraoperative variables were recorded. Hypothermia was defined as a urinary bladder temperature<35°C. Multiple logistic regression analysis was conducted to identify independent significant predictors of postoperative complications. In addition, the authors also determined a cutoff point for intraoperative minimum urinary bladder temperature by analyzing receiver operating characteristic (ROC) curves for occurrence of adverse events at 1 month after surgery. No patients died within 1 month after the surgery. There were 53 patients with early postoperative complications, and 51 had experienced intraoperative hypothermia. Factors that were correlated significantly with complications included age (p=0.02); hypothermia (p<0.01); and doses of ephedrine (p<0.01), phenylephrine (p<0.01), and fentanyl (p<0.01). Multiple logistic regression analysis identified intraoperative hypothermia as a significant independent predictor for the development of early perioperative complications (odds ratio 2.57; 95% confidence interval 1.09-6.08). The area under the ROC curve for body temperature was 0.71, and the cutoff point was 35°C (sensitivity=0.65, specificity=0.72). CONCLUSIONS: Intraoperative hypothermia was identified as an independent risk factor for early postoperative adverse events following esophagectomy.


Assuntos
Temperatura Corporal/fisiologia , Neoplasias Esofágicas/cirurgia , Esofagectomia/métodos , Hipotermia/complicações , Complicações Pós-Operatórias/etiologia , Idoso , Feminino , Seguimentos , Humanos , Hipotermia/epidemiologia , Hipotermia/fisiopatologia , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Prognóstico , Curva ROC , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA