Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Intern Med ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38987191

RESUMO

A six-year-old boy presented with short stature and gingival fibromatosis (GF). Dysmorphic features included slant optic fissures, a high-arched palate, thick earlobes, and an edematous face. Laboratory tests showed low levels of serum insulin-like growth factor-1 and serum free thyroxine but normal serum thyrotropin levels. Provocative tests suggested growth hormone deficiency, central hypocortisolemia, and hypothalamic hypothyroidism. At 12 years old, hypogonadotropic hypogonadism was observed. Next-generation sequencing revealed a heterozygous missense variant, KCNQ1 p. (P369L), in the proband and mother. The coexistence of multiple pituitary hormone deficiencies and GF helps diagnose KCNQ1-variant dysmorphic syndrome through genetic testing.

2.
Biomed Phys Eng Express ; 10(4)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38744248

RESUMO

Evaluating neutron output is important to ensure proper dose delivery for patients in boron neutron capture therapy (BNCT). It requires efficient quality assurance (QA) and quality control (QC) while maintaining measurement accuracy. This study investigated the optimal measurement conditions for QA/QC of activation measurements using a high-purity germanium (HP-Ge) detector in an accelerator-based boron neutron capture therapy (AB-BNCT) system employing a lithium target. The QA/QC uncertainty of the activation measurement was evaluated based on counts, reproducibility, and standard radiation source uncertainties. Measurements in a polymethyl methacrylate (PMMA) cylindrical phantom using aluminum-manganese (Al-Mn) foils and aluminum-gold (Al-Au) foils and measurements in a water phantom using gold wire with and without cadmium cover were performed to determine the optimal measurement conditions. The QA/QC uncertainties of the activation measurements were 4.5% for Au and 4.6% for Mn. The optimum irradiation proton charge and measurement time were determined to be 36 C and 900 s for measurements in a PMMA cylindrical phantom, 7.0 C and 900 s for gold wire measurements in a water phantom, and 54 C and 900 s at 0-2.2 cm depth and 3,600 s at deeper depths for gold wire measurements with cadmium cover. Our results serve as a reference for determining measurement conditions when performing QA/QC of activation measurements using HP-Ge detectors at an AB-BNCT employing a lithium target.


Assuntos
Terapia por Captura de Nêutron de Boro , Lítio , Aceleradores de Partículas , Imagens de Fantasmas , Controle de Qualidade , Lítio/química , Terapia por Captura de Nêutron de Boro/métodos , Humanos , Aceleradores de Partículas/instrumentação , Reprodutibilidade dos Testes , Polimetil Metacrilato/química , Nêutrons , Ouro/química , Alumínio/química , Água/química , Radiometria/métodos , Radiometria/instrumentação , Dosagem Radioterapêutica
3.
Artigo em Inglês | MEDLINE | ID: mdl-38373250

RESUMO

CONTEXT: Thyroglobulin (Tg), encoded by TG, is essential for thyroid hormone synthesis. TG defects result in congenital hypothyroidism (CH). Most reported patients were born before the introduction of newborn screening (NBS). OBJECTIVE: We aimed to clarify the phenotypic features of patients with TG defects diagnosed and treated since the neonatal period. SUBJECTS AND METHODS: We screened 1061 patients with CH for thirteen CH-related genes and identified thirty patients with TG defects. One patient was diagnosed due to hypothyroidism-related symptoms and the rest were diagnosed via NBS. Patients were divided into two groups according to their genotypes, and clinical characteristics were compared. We evaluated the functionality of the seven missense variants using HEK293 cells. RESULTS: Twenty-seven rare TG variants were detected, including fifteen nonsense, three frameshift, two splice-site, and seven missense variants. Patients were divided into two groups: thirteen patients with biallelic truncating variants and seventeen patients with monoallelic/biallelic missense variants. Patients with missense variants were more likely to develop thyroid enlargement with TSH stimulation than patients with biallelic truncating variants. Patients with biallelic truncating variants invariably required full hormone replacement, whereas patients with missense variants required variable doses of levothyroxine. Loss of function of the seven missense variants was confirmed in vitro. CONCLUSION: To our knowledge, this is the largest investigation on the clinical presentation of TG defects diagnosed in the neonatal period. Patients with missense variants showed relatively mild hypothyroidism with compensative goiter. Patients with only truncating variants showed minimal or no compensative goiter and required full hormone replacement.

4.
Clin Transl Radiat Oncol ; 42: 100659, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37519921

RESUMO

We first used MucoUp®, a hyaluronic acid used in endoscopic resection, as a spacer in brachytherapy. In five cervical cancer patients, MucoUp® insertion increased a 90% dose of the high-risk CTV to over 80 Gy while decreasing the dose of organs at risk. No related adverse events were observed.

5.
BJR Open ; 5(1): 20220037, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37035770

RESUMO

Objective: Intensity-modulated radiotherapy (IMRT) is a well-established radiotherapy technique for delivering radiation to cancer with high conformity while sparing the surrounding normal tissue. Two main purposes of this study are: (1) to investigate dose calculation accuracy of helical IMRT (HIMRT) and volumetric-modulated arc therapy (VMAT) on surface region and (2) to evaluate the dosimetric efficacy of HIMRT and VMAT for scalp-sparing in whole brain radiotherapy (WBRT). Methods: First, using a radiochromic film and water-equivalent phantom with three types of boluses (1, 3, 5 mm), calculation/measurement dose agreement at the surface region in the VMAT and HIMRT plans were examined. Then, HIMRT, 6MV-VMAT and 10MV-VMAT with scalp-sparing, and two conventional three-dimensional conformal radiotherapy plans (6MV-3DCRT and 10MV-3DCRT; as reference data) were created for 30 patients with brain metastasis (30 Gy/10 fractions). The mean dose to the scalp and the scalp volume receiving 24 and 30 Gy were compared. Results: The percentage dose differences between the calculation and measurement were within 7%, except for the HIMRT plan at a depth of 1 mm. The averaged mean scalp doses [Gy], V24Gy [%], and V30Gy [%] (1SD) for 6MV-3DCRT, 10MV-3DCRT, HIMRT, 6MV-VMAT, and 10MV-VMAT were [26.6 (1.1), 86.4 (7.3), 13.2 (4.2)], [25.4 (1.0), 77.8 (7.5), 13.2 (4.2)], [23.2 (1.5), 42.8 (19.2), 0.2 (0.5)], [23.6 (1.6), 47.5 (17.9), 1.2 (1.8)], and [22.7 (1.7), 36.4 (17.6), 0.7 (1.1)], respectively. Conclusion: Regarding the dose parameters, HIMRT achieved a lower scalp dose compared with 6MV-VMAT. However, the highest ability to reduce the mean scalp dose was showed in 10MV-VMAT. Advances in knowledge: Scalp-sparing WBRT using HIMRT or VMAT may prevent radiation-induced alopecia in patients with BM.

6.
Phys Med ; 100: 105-111, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35797917

RESUMO

PURPOSE: We investigated the localization accuracy of the off-isocenter targets using SyncTraX FX4, a new image registration device. METHODS: In a phantom study, we used a MultiMet-WL Cube with metal targets at different distances from the isocenter. Image registrations were performed with SyncTraX and cone-beam computed tomography (CBCT). Nineteen fields with different gantry, collimator, and couch angles were delivered to each target. Localization errors of the off-isocenter targets were then evaluated. In a clinical study, localization accuracy was evaluated for 32 patients. First, image registration was performed using SyncTraX, and the accuracy of patient positioning was evaluated using CBCT. Next, positioning corrections were performed for intracranial setup errors exceeding the threshold (0.5 mm/0.5°) in each field. Finally, total setup uncertainty was evaluated using CBCT. Differences in dosimetric errors from planned doses between no patient positioning corrections during treatment and positioning corrections with SyncTraX were also evaluated. RESULTS: In the phantom study, the positioning accuracy on targets up to 7 cm from the isocenter was within 1 mm. In the clinical practice, the localization accuracies of SyncTraX were 0.35 ± 0.39 mm, 0.30 ± 0.24 mm, and 0.03 ± 0.27 mm in the lateral, vertical, and longitudinal directions, respectively. Post-treatment setup errors were reduced by correcting intrafractional setup errors with SyncTraX during treatment. Positioning corrections with SyncTraX reduced the maximum dosimetric error from 1.6% to 1.0%. CONCLUSIONS: SyncTraX provides satisfactory localization accuracy for the off-isocenter targets within 7 cm. SyncTraX reduce dosimetric errors caused by intrafractional setup errors during treatment.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiocirurgia , Humanos , Imagens de Fantasmas , Radiometria , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
7.
J Appl Clin Med Phys ; 22(9): 360-370, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34347933

RESUMO

PURPOSE: We investigated the immobilization accuracy of a new type of thermoplastic mask-the Double Shell Positioning System (DSPS)-in terms of geometry and dose delivery. METHODS: Thirty-one consecutive patients with 1-5 brain metastases treated with stereotactic radiotherapy (SRT) were selected and divided into two groups. Patients were divided into two groups. One group of patients was immobilized by the DSPS (n = 9). Another group of patients was immobilized by a combination of the DSPS and a mouthpiece (n = 22). Patient repositioning was performed with cone beam computed tomography (CBCT) and six-degree of freedom couch. Additionally, CBCT images were acquired before and after treatment. Registration errors were analyzed with off-line review. The inter- and intrafractional setup errors, and planning target volume (PTV) margin were also calculated. Delivered doses were calculated by shifting the isocenter according to inter- and intrafractional setup errors. Dose differences of GTV D99% were compared between planned and delivered doses against the modified PTV margin of 1 mm. RESULTS: Interfractional setup errors associated with the mouthpiece group were significantly smaller than the translation errors in another group (p = 0.03). Intrafractional setup errors for the two groups were almost the same in all directions. PTV margins were 0.89 mm, 0.75 mm, and 0.90 mm for the DSPS combined with the mouthpiece in lateral, vertical, and longitudinal directions, respectively. Similarly, PTV margins were 1.20 mm, 0.72 mm, and 1.37 mm for the DSPS in the lateral, vertical, and longitudinal directions, respectively. Dose differences between planned and delivered doses were small enough to be within 1% for both groups. CONCLUSIONS: The geometric and dosimetric assessments revealed that the DSPS provides sufficient immobilization accuracy. Higher accuracy can be expected when the immobilization is combined with the use of a mouthpiece.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Erros de Configuração em Radioterapia , Encéfalo , Humanos , Imobilização , Posicionamento do Paciente , Erros de Configuração em Radioterapia/prevenção & controle
8.
Radiol Phys Technol ; 14(3): 238-247, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34132994

RESUMO

This study aims to implement three-dimensional convolutional neural networks (3D-CNN) for clinical target volume (CTV) segmentation for whole breast irradiation and investigate the focus of 3D-CNNs during decision-making using gradient-weighted class activation mapping (Grad-CAM). A 3D-UNet CNN was adopted to conduct automatic segmentation of the CTV for breast cancer. The 3D-UNet was trained using three datasets of left-, right-, and both left- and right-sided breast cancer patients. Segmentation accuracy was evaluated using the Dice similarity coefficient (DSC). Grad-CAM was applied to trained CNNs. The DSCs for the datasets of the left-, right-, and both left- and right-sided breasts were on an average 0.88, 0.89, and 0.85, respectively. The Grad-CAM heatmaps showed that the 3D-UNet used for segmentation determined the CTV region from the target-side breast tissue and by referring to the opposite-side breast. Although the size of the dataset was limited, DSC ≥ 0.85 was achieved for the segmentation of breast CTV using the 3D-UNet. Grad-CAM indicates the applicable scope and limitations of using a CNN by indicating the focus of such networks during decision-making.


Assuntos
Neoplasias da Mama , Redes Neurais de Computação , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Feminino , Humanos
9.
J Appl Clin Med Phys ; 22(2): 108-117, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33426810

RESUMO

This study evaluated unexpected dosimetric errors caused by machine control accuracy, patient setup errors, and patient weight changes/internal organ deformations. Trajectory log files for 13 gynecologic plans with seven- or nine-beam dynamic multileaf collimator (MLC) intensity-modulated radiation therapy (IMRT), and differences between expected and actual MLC positions and MUs were evaluated. Effects of patient setup errors on dosimetry were estimated by in-house software. To simulate residual patient setup errors after image-guided patient repositioning, planned dose distributions were recalculated (blurred dose) after the positions were randomly moved in three dimensions 0-2 mm (translation) and 0°-2° (rotation) 28 times per patient. Differences between planned and blurred doses in the clinical target volume (CTV) D98% and D2% were evaluated. Daily delivered doses were calculated from cone-beam computed tomography by the Hounsfield unit-to-density conversion method. Fractional and accumulated dose differences between original plans and actual delivery were evaluated by CTV D98% and D2% . The significance of accumulated doses was tested by the paired t test. Trajectory log file analysis showed that MLC positional errors were -0.01 ± 0.02 mm and MU delivery errors were 0.10 ± 0.10 MU. Differences in CTV D98% and D2% were <0.5% for simulated patient setup errors. Differences in CTV D98% and D2% were 2.4% or less between the fractional planned and delivered doses, but were 1.7% or less for the accumulated dose. Dosimetric errors were primarily caused by patient weight changes and internal organ deformation in gynecologic radiation therapy.


Assuntos
Neoplasias , Radioterapia de Intensidade Modulada , Tomografia Computadorizada de Feixe Cônico , Feminino , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
10.
Nat Commun ; 11(1): 1421, 2020 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-32184391

RESUMO

Uncoupling protein-1 (UCP1) plays a central role in energy dissipation in brown adipose tissue (BAT). Using high-throughput library screening of secreted peptides, we identify two fibroblast growth factors (FGF), FGF6 and FGF9, as potent inducers of UCP1 expression in adipocytes and preadipocytes. Surprisingly, this occurs through a mechanism independent of adipogenesis and involves FGF receptor-3 (FGFR3), prostaglandin-E2 and interaction between estrogen receptor-related alpha, flightless-1 (FLII) and leucine-rich-repeat-(in FLII)-interacting-protein-1 as a regulatory complex for UCP1 transcription. Physiologically, FGF6/9 expression in adipose is upregulated by exercise and cold in mice, and FGF9/FGFR3 expression in human neck fat is significantly associated with UCP1 expression. Loss of FGF9 impairs BAT thermogenesis. In vivo administration of FGF9 increases UCP1 expression and thermogenic capacity. Thus, FGF6 and FGF9 are adipokines that can regulate UCP1 through a transcriptional network that is dissociated from brown adipogenesis, and act to modulate systemic energy metabolism.


Assuntos
Adipócitos Marrons/metabolismo , Adipogenia , Fator 6 de Crescimento de Fibroblastos/metabolismo , Fator 9 de Crescimento de Fibroblastos/metabolismo , Obesidade/metabolismo , Proteína Desacopladora 1/metabolismo , Adipócitos Marrons/citologia , Tecido Adiposo Marrom/citologia , Tecido Adiposo Marrom/metabolismo , Animais , Fator 6 de Crescimento de Fibroblastos/genética , Fator 9 de Crescimento de Fibroblastos/genética , Humanos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Obesidade/genética , Obesidade/fisiopatologia , Termogênese , Proteína Desacopladora 1/genética
11.
Diabetes Metab Syndr Obes ; 12: 1473-1492, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31692556

RESUMO

BACKGROUND AND AIMS: Nonalcoholic fatty liver disease (NAFLD) is a hepatic manifestation of metabolic syndrome, and its progression is associated with aging-associated impairment in metabolic homeostasis. Recently, energy metabolism in adipose tissue has been the subject of renewed interest, because significant energy expenditure can be induced in cells derived from white adipose tissue progenitors, in addition to brown adipose tissue (BAT). Here we evaluated whether aging-associated change in various adipose tissue depots affects the progression of NAFLD. METHODS: Six-week-old male C57BL/6NCrSlc mice were fed control chow (C) or high-fat diet (60% fat; HF) for 12 or 24 weeks (12w/C, 12w/HF, 24w/C and 24w/HF groups, respectively) or switched from C to HF diet at 18 weeks of age (24w/C/HF group) and fed for a further 24 weeks. Some 24w/HF mice received a subcutaneous transplantation of adipose progenitors (106 cells/mouse) from young donor mice. Basal energy expenditure, glucose tolerance, and liver and adipose tissue histology were then evaluated. In addition, features of senescence and the capacity of adipose progenitors to "brown" were compared in mice of various ages. RESULTS: 12w/HF mice demonstrated compensation in the forms of hypertrophy of interscapular classical BAT and the appearance of subcutaneous beige adipocytes, consistent with improved metabolic homeostasis. In contrast, 24w/HF and 24w/C/HF mice developed obesity, glucose intolerance, and severe NAFLD, with accelerated senescence and loss of adipose progenitors in subcutaneous fat tissues. Recruitment of adipose progenitors ameliorated these findings in 24w/HF mice. CONCLUSION: Impaired metabolic compensation in adipose tissue resulted in the progression of NAFLD, which was associated with aging-related deterioration in adipose progenitors. A new approach targeting adipose tissue progenitors might represent a potential strategy for the prevention of NAFLD.

12.
J Radiat Res ; 60(3): 401-411, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30929023

RESUMO

The purpose of this study was to quantify actual patient organ doses from megavoltage computed tomography (MVCT) using an MVCT beam model of a helical tomotherapy unit in a general treatment planning system (TPS). Dosimetric parameters (percentage depth dose, lateral beam profile, and longitudinal beam profile) of the MVCT beam were measured using Gafchromic EBT3 films (ISP Corporation, Wayne, NJ, USA) and used for beam modeling in a Pinnacle3 TPS (Philips, Amsterdam, Netherlands); this TPS is widely used with linear accelerators. The created beam model was adjusted and validated by assessing point doses in a cylindrical phantom in static and helical beam plans with fine, normal and coarse pitches. Maximum doses delivered to important organs from MVCT delivery for five clinical cases were calculated using the created beam model. The difference (average ± one standard deviation for all evaluation points) between calculated and measured doses was -0.69 ± 1.20% in the static beam plan. In the helical beam plan, the differences were 1.83 ± 2.65%, 1.35 ± 5.94% and -0.66 ± 8.48% for fine, normal and coarse pitches, respectively. The average maximum additional dose to important organs from MVCT in clinical cases was 0.82% of the prescribed dose. In conclusion, we investigated a method for quantifying patient organ dose from MVCT delivery on helical tomotherapy using an MVCT beam model in a general TPS. This technique enables estimation of the patient-specific organ dose from MVCT delivery, without the need for additional equipment.


Assuntos
Especificidade de Órgãos/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada Espiral , Calibragem , Relação Dose-Resposta à Radiação , Humanos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
13.
PLoS One ; 14(1): e0210184, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30608967

RESUMO

Rett syndrome (RTT) is an X-linked neurodevelopmental disorder caused by mutation of the methyl-CpG-binding protein 2 (MECP2) gene. Although RTT has been associated with obesity, the underlying mechanism has not yet been elucidated. In this study, female heterozygous Mecp2-null mice (Mecp2+/- mice), a model of RTT, were fed a normal chow diet or high-fat diet (HFD), and the changes in molecular signaling pathways were investigated. Specifically, we examined the expression of genes related to the hypothalamus and dopamine reward circuitry, which represent a central network of feeding behavior control. In particular, dopamine reward circuitry has been shown to regulate hedonic feeding behavior, and its disruption is associated with HFD-related changes in palatability. The Mecp2+/- mice that were fed the normal chow showed normal body weight and food consumption, whereas those fed the HFD showed extreme obesity with hyperphagia, an increase of body fat mass, glucose intolerance, and insulin resistance compared with wild-type mice fed the HFD (WT-HFD mice). The main cause of obesity in Mecp2+/--HFD mice was a remarkable increase in calorie intake, with no difference in oxygen consumption or locomotor activity. Agouti-related peptide mRNA and protein levels were increased, whereas proopiomelanocortin mRNA and protein levels were reduced in Mecp2+/--HFD mice with hyperleptinemia, which play an essential role in appetite and satiety in the hypothalamus. The conditioned place preference test revealed that Mecp2+/- mice preferred the HFD. Tyrosine hydroxylase and dopamine transporter mRNA levels in the ventral tegmental area, and dopamine receptor and dopamine- and cAMP-regulated phosphoprotein mRNA levels in the nucleus accumbens were significantly lower in Mecp2+/--HFD mice than those of WT-HFD mice. Thus, HFD feeding induced dysregulation of food intake in the hypothalamus and dopamine reward circuitry, and accelerated the development of extreme obesity associated with addiction-like eating behavior in Mecp2+/- mice.


Assuntos
Dieta Hiperlipídica/efeitos adversos , Hiperfagia/etiologia , Proteína 2 de Ligação a Metil-CpG/genética , Obesidade/etiologia , Síndrome de Rett/complicações , Animais , Apetite/fisiologia , Modelos Animais de Doenças , Dopamina/metabolismo , Comportamento Alimentar/fisiologia , Feminino , Heterozigoto , Humanos , Hiperfagia/diagnóstico , Hiperfagia/fisiopatologia , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Obesidade/diagnóstico , Obesidade/fisiopatologia , Síndrome de Rett/genética , Recompensa , Índice de Gravidade de Doença , Fatores de Tempo , Área Tegmentar Ventral/metabolismo , Área Tegmentar Ventral/fisiopatologia
14.
PLoS One ; 12(3): e0173661, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28288167

RESUMO

Erythropoietin (EPO), clinically used as a hematopoietic drug, has received much attention due to its nonhematopoietic effects. EPO reportedly has beneficial effects on obesity and diabetes mellitus. We investigated whether interscapular brown adipose tissue (iBAT: main part of classical BAT) could play a role in EPO's anti-obesity and anti-diabetic effects in diet-induced obese mice. Four-week-old male C57BL/6J mice were fed a high-fat diet (HFD-Con), and half were additionally given an intraperitoneal injection of recombinant human EPO (200 IU/kg) (HFD-EPO) thrice a week for four weeks. At 8 weeks, EPO-injected mice showed significantly reduced body weight with reduced epididymal and subcutaneous white fat mass and unchanged caloric intake and locomotor activity. HOMA-IR (insulin resistance index) and glucose levels during intraperitoneal glucose tolerance test (IPGTT) were significantly lower in HFD-EPO mice than in HFD-Con mice. EPO-injected mice also showed increased oxygen consumption, indicative of metabolic rate, and skin temperature around iBAT tissue masses. EPO significantly upregulated the PRD1-BF1-RIZ1 homologous domain containing 16 (PRDM16), a transcriptional factor with a crucial role in brown adipocyte differentiation. EPO significantly increased phosphorylated signal transducer and activator of transcription 3 (STAT3), which is downstream of erythropoietin receptor (EpoR) and known to stabilize PRDM16. EPO's suppression of myocyte enhancer factor 2c (Mef2c) and microRNA-133a (miR-133a) via ß3-adrenergic receptor caused PRDM16 upregulation. EPO-mediated enhancement of EpoR/STAT3 and ß-adrenergic receptor/Mef2c/miR-133 pathways dramatically increases total uncoupling protein 1 (UCP1), an essential enzyme for BAT thermogenesis. Furthermore, EPO activated BAT's endocrine functions. EPO facilitated fibroblast growth factor 21 (FGF21) production and excretion in iBAT, associated with reduction of liver gluconeogenesis-related genes. Thus, EPO's improvement of obesity and glucose homeostasis can be attributed to increased iBAT thermogenic capacity and activation of BAT's endocrine functions.


Assuntos
Tecido Adiposo Marrom/metabolismo , Eritropoetina/metabolismo , Eritropoetina/farmacologia , Obesidade/etiologia , Termogênese/fisiologia , Adipócitos/efeitos dos fármacos , Adipócitos/metabolismo , Tecido Adiposo Marrom/efeitos dos fármacos , Tecido Adiposo Branco/efeitos dos fármacos , Tecido Adiposo Branco/metabolismo , Animais , Fármacos Antiobesidade/farmacologia , Proteínas de Ligação a DNA/metabolismo , Dieta Hiperlipídica/efeitos adversos , Metabolismo Energético/efeitos dos fármacos , Fatores de Crescimento de Fibroblastos/metabolismo , Intolerância à Glucose/tratamento farmacológico , Teste de Tolerância a Glucose , Resistência à Insulina , Masculino , Camundongos Endogâmicos C57BL , Obesidade/tratamento farmacológico , Termogênese/efeitos dos fármacos , Fatores de Transcrição/metabolismo
15.
Int J Radiat Oncol Biol Phys ; 96(3): 661-9, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27681763

RESUMO

PURPOSE: To investigate the impact of setup and range uncertainties, breathing motion, and interplay effects using scanning pencil beams in robustly optimized intensity modulated proton therapy (IMPT) for stage III non-small cell lung cancer (NSCLC). METHODS AND MATERIALS: Three-field IMPT plans were created using a minimax robust optimization technique for 10 NSCLC patients. The plans accounted for 5- or 7-mm setup errors with ±3% range uncertainties. The robustness of the IMPT nominal plans was evaluated considering (1) isotropic 5-mm setup errors with ±3% range uncertainties; (2) breathing motion; (3) interplay effects; and (4) a combination of items 1 and 2. The plans were calculated using 4-dimensional and average intensity projection computed tomography images. The target coverage (TC, volume receiving 95% of prescribed dose) and homogeneity index (D2 - D98, where D2 and D98 are the least doses received by 2% and 98% of the volume) for the internal clinical target volume, and dose indexes for lung, esophagus, heart and spinal cord were compared with that of clinical volumetric modulated arc therapy plans. RESULTS: The TC and homogeneity index for all plans were within clinical limits when considering the breathing motion and interplay effects independently. The setup and range uncertainties had a larger effect when considering their combined effect. The TC decreased to <98% (clinical threshold) in 3 of 10 patients for robust 5-mm evaluations. However, the TC remained >98% for robust 7-mm evaluations for all patients. The organ at risk dose parameters did not significantly vary between the respective robust 5-mm and robust 7-mm evaluations for the 4 error types. Compared with the volumetric modulated arc therapy plans, the IMPT plans showed better target homogeneity and mean lung and heart dose parameters reduced by about 40% and 60%, respectively. CONCLUSIONS: In robustly optimized IMPT for stage III NSCLC, the setup and range uncertainties, breathing motion, and interplay effects have limited impact on target coverage, dose homogeneity, and organ-at-risk dose parameters.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Órgãos em Risco/efeitos da radiação , Terapia com Prótons/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Mecânica Respiratória , Carcinoma Pulmonar de Células não Pequenas/patologia , Relação Dose-Resposta à Radiação , Humanos , Neoplasias Pulmonares/patologia , Movimento (Física) , Estadiamento de Neoplasias , Posicionamento do Paciente/métodos , Exposição à Radiação/análise , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Carga Tumoral/efeitos da radiação
16.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 72(6): 469-79, 2016 Jun.
Artigo em Japonês | MEDLINE | ID: mdl-27320150

RESUMO

To realize the high precision radiotherapy, localized radiation field of the moving target is very important, and visualization of a temporal location of the target can help to improve the accuracy of the target localization. However, conditions of the breathing and the patient's own motion differ from the situation of the treatment planning. Therefore, positions of the tumor are affected by these changes. In this study, we implemented a method to reconstruct target motions obtained with the 4D CBCT using the sorted projection data according to the phase and displacement of the extracorporeal infrared monitor signal, and evaluated the proposed method with a moving phantom. In this method, motion cycles and positions of the marker were sorted to reconstruct the image, and evaluated the image quality affected by changes in the cycle, phase, and positions of the marker. As a result, we realized the visualization of the moving target using the sorted projection data according to the infrared monitor signal. This method was based on the projection binning, in which the signal of the infrared monitor was surrogate of the tumor motion. Thus, further major efforts are needed to ensure the accuracy of the infrared monitor signal.


Assuntos
Tomografia Computadorizada de Feixe Cônico/normas , Processamento de Imagem Assistida por Computador , Raios Infravermelhos , Radioterapia Guiada por Imagem/métodos , Imagens de Fantasmas
17.
Med Phys ; 42(8): 4745-54, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26233202

RESUMO

PURPOSE: To develop and evaluate a new video image-based QA system, including in-house software, that can display a tracking state visually and quantify the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system. METHODS: Sixteen trajectories in six patients with pulmonary cancer were obtained with the ExacTrac in the Vero4DRT system. Motion data in the cranio-caudal direction (Y direction) were used as the input for a programmable motion table (Quasar). A target phantom was placed on the motion table, which was placed on the 2D ionization chamber array (MatriXX). Then, the 4D modeling procedure was performed on the target phantom during a reproduction of the patient's tumor motion. A substitute target with the patient's tumor motion was irradiated with 6-MV x-rays under the surrogate infrared system. The 2D dose images obtained from the MatriXX (33 frames/s; 40 s) were exported to in-house video-image analyzing software. The absolute differences in the Y direction between the center of the exposed target and the center of the exposed field were calculated. Positional errors were observed. The authors' QA results were compared to 4D modeling function errors and gimbal motion errors obtained from log analyses in the ExacTrac to verify the accuracy of their QA system. The patients' tumor motions were evaluated in the wave forms, and the peak-to-peak distances were also measured to verify their reproducibility. RESULTS: Thirteen of sixteen trajectories (81.3%) were successfully reproduced with Quasar. The peak-to-peak distances ranged from 2.7 to 29.0 mm. Three trajectories (18.7%) were not successfully reproduced due to the limited motions of the Quasar. Thus, 13 of 16 trajectories were summarized. The mean number of video images used for analysis was 1156. The positional errors (absolute mean difference + 2 standard deviation) ranged from 0.54 to 1.55 mm. The error values differed by less than 1 mm from 4D modeling function errors and gimbal motion errors in the ExacTrac log analyses (n = 13). CONCLUSIONS: The newly developed video image-based QA system, including in-house software, can analyze more than a thousand images (33 frames/s). Positional errors are approximately equivalent to those in ExacTrac log analyses. This system is useful for the visual illustration of the progress of the tracking state and for the quantification of positional accuracy during dynamic tumor tracking irradiation in the Vero4DRT system.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Gravação em Vídeo/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Marcadores Fiduciais , Humanos , Neoplasias Pulmonares/radioterapia , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Imagens de Fantasmas , Radioterapia Guiada por Imagem/instrumentação , Software
18.
Breast Cancer ; 21(4): 402-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22968629

RESUMO

PURPOSE: To evaluate the efficacy and safety of hypofractionated whole-breast irradiation (HF-WBI) compared with conventionally fractionated (CF) WBI. MATERIALS AND METHODS: Patients with early breast cancer (stages 0-II and <3 positive lymph nodes) who had undergone breast-conserving surgery were eligible for the HF-WBI study. HF-WBI was administered at 43.2 Gy in 16 fractions over 3.2 weeks to the whole breast with an additional tumor-bed boost of 8.1 Gy in 3 fractions over 3 days for positive surgical margins or those <5 mm. CF-WBI was administered at 50 Gy in 25 fractions over 5 weeks to the whole breast with an additional tumor-bed boost of 16 Gy in 8 fractions over 1.4 weeks to 6 Gy in 3 fractions over 3 days, depending on margin status. RESULTS: From April 1, 2006, to December 31, 2010, 717 patients were registered and 734 breasts were treated by HF-WBI. In the same period, 381 patients and 393 breasts who matched the study criteria chose CF-WBI, so the total number of patients in this comparison was 1,098. Grade 2 acute skin reactions were observed for 24 patients (3 %) in the HF-WBI group and 53 patients (14 %) in the CF-WBI (p < 0.001) group. The median follow-up period was 27 months. Two cases of intrabreast tumor recurrence were observed in each treatment group. Regional lymph node recurrence was observed in 1 HF-WBI patient and 2 CF-WBI patients. CONCLUSION: HF-WBI is superior to CF-WBI in terms of acute skin reaction and has the same short-term efficacy.


Assuntos
Neoplasias da Mama/radioterapia , Carcinoma Ductal de Mama/radioterapia , Carcinoma Intraductal não Infiltrante/radioterapia , Fracionamento da Dose de Radiação , Recidiva Local de Neoplasia/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/secundário , Carcinoma Intraductal não Infiltrante/secundário , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Invasividade Neoplásica , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Prognóstico , Adulto Jovem
19.
J Radiat Res ; 54(1): 157-65, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22859565

RESUMO

To evaluate the dosimetric impact of respiratory breast motion and daily setup error on whole breast irradiation (WBI) using three irradiation techniques; conventional wedge (CW), field-in-field (FIF) and irregular surface compensator (ISC). WBI was planned for 16 breast cancer patients. The dose indices for evaluated clinical target volume (CTV(evl)), lung, and body were evaluated. For the anterior-posterior (AP) respiratory motion and setup error of a single fraction, the isocenter was moved according to a sine function, and the dose indices were averaged over one period. Furthermore, the dose indices were weighted according to setup error frequencies that have a normal distribution to model systematic and random setup error for the entire treatment course. In all irradiation techniques, AP movement has a significant impact on dose distribution. CTV(evl)D(95) (the minimum relative dose that covers 95 % volume) and V(95) (the relative volume receiving 95 % of the prescribed dose) were observed to significantly decrease from the original ISC plan when simulated for the entire treatment course. In contrast, the D(95), V(95) and dose homogeneity index did not significantly differ from those of the original plans for FIF and CW. With regard to lung dose, the effect of motion was very similar among all three techniques. The dosimetric impact of AP respiratory breast motion and setup error was largest for the ISC technique, and the second greatest effect was observed with the FIF technique. However, these variations are relatively small.


Assuntos
Artefatos , Neoplasias da Mama/radioterapia , Movimento , Posicionamento do Paciente/métodos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Mecânica Respiratória , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Radiografia , Dosagem Radioterapêutica , Radioterapia Conformacional , Radioterapia Guiada por Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
20.
Radiol Phys Technol ; 6(1): 14-20, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22752600

RESUMO

We compared treatment plans for volumetric intensity-modulated arc therapy (VMAT) and step-and-shoot intensity-modulated radiation therapy (IMRT) in terms of their monitor unit (MU) and segment area at each control point to investigate the difference between the two methods. We investigated three sites: prostate (three cases), head and neck (three cases), and pleura (two cases). We used the total MU and the MU weighted average of segment area (MWSA) in each plan to compare VMAT and IMRT plans. VMAT plans tended to have a larger MWSA and a lower total MU than did IMRT plans in all sites, although there was little difference between dose indices in either irradiation technique. We conclude that VMAT is a better treatment technique due to its higher MU efficiency caused by the larger segment area.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Masculino , Neoplasias/radioterapia , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA