1.
Pacing Clin Electrophysiol ; 40(11): 1254-1259, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28895163

RESUMO

BACKGROUND: Fluoroless transseptal (TS) puncture may represent the final step toward elimination of fluoroscopy in pediatric supraventricular tachycardia ablation in normal hearts. We aimed to demonstrate the safety and feasibility of fluoroless TS puncture in pediatric patients and compare procedural timing with the fluoroscopic approach. METHODS: We performed a retrospective cohort analysis of all TS procedures performed without fluoroscopy at our institution; fluoroless TS procedures were performed under intracardiac echocardiography (ICE) guidance after the creation of a 3D electroanatomic map and identification of fossa ovalis (FO) on 3D map. TS procedure times reported are the time from sheath insertion (8.5F short sheath for ICE catheter and SL-1 for TS needle) to the time of confirmed left atrial access. Prior TS procedures performed by the same operator utilizing a combination of ICE and fluoroscopy and by a second operator utilizing fluoroscopic guidance alone were used for comparison. RESULTS: Fluoroless TS puncture was performed in nine patients (mean age 13.8 years); the site of TS puncture was within 2 mm of the FO identified on the EA map. The mean TS procedure time was 22.2 minutes (range 10-45). There was no significant difference in TS procedure times between the three groups. There were no complications related to any TS procedure. CONCLUSION: Fluoroless TS procedures utilizing ICE can safely be performed in pediatric patients without adding substantial procedural times compared with those utilizing fluoroscopic guidance.


Assuntos
Ablação por Cateter/métodos , Fluoroscopia/estatística & dados numéricos , Septos Cardíacos/cirurgia , Taquicardia Supraventricular/cirurgia , Adolescente , Criança , Ecocardiografia , Estudos de Viabilidade , Humanos , Duração da Cirurgia , Segurança do Paciente , Punções , Estudos Retrospectivos , Taquicardia Supraventricular/diagnóstico por imagem , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 28(5): 517-522, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28245348

RESUMO

BACKGROUND: Arrhythmia ablation with current techniques is not universally successful. Inadequate ablation lesion formation may be responsible for some arrhythmia recurrences. Periprocedural visualization of ablation lesions may identify inadequate lesions and gaps to guide further ablation and reduce risk of arrhythmia recurrence. METHODS: This feasibility study assessed acute postprocedure ablation lesions by MRI, and correlated these findings with clinical outcomes. Ten pediatric patients who underwent ventricular tachycardia ablation were transferred immediately postablation to a 1.5T MRI scanner and late gadolinium enhancement (LGE) imaging was performed to characterize ablation lesions. Immediate and mid-term arrhythmia recurrences were assessed. RESULTS: Patient characteristics include median age 14 years (1-18 years), median weight 52 kg (11-81 kg), normal cardiac anatomy (n = 6), d-transposition of great arteries post arterial switch repair (n = 2), anomalous coronary artery origin post repair (n = 1), and cardiac rhabdomyoma (n = 1). All patients underwent radiofrequency catheter ablation of ventricular arrhythmia with acute procedural success. LGE was identified at the reported ablation site in 9/10 patients, all arrhythmia-free at median 7 months follow-up. LGE was not visible in 1 patient who had recurrence of frequent premature ventricular contractions within 2 hours, confirmed on Holter at 1 and 21 months post procedure. CONCLUSIONS: Ventricular ablation lesion visibility by MRI in the acute post procedure setting is feasible. Lesions identifiable with MRI may correlate with clinical outcomes. Acute MRI identification of gaps or inadequate lesions may provide the unique temporal opportunity for additional ablation therapy to decrease arrhythmia recurrence.


Assuntos
Ablação por Cateter , Ventrículos do Coração/cirurgia , Imageamento por Ressonância Magnética , Taquicardia Ventricular/cirurgia , Adolescente , Fatores Etários , Ablação por Cateter/efeitos adversos , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Recidiva , Fatores de Risco , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
3.
J Interv Card Electrophysiol ; 46(2): 183-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26768435

RESUMO

PURPOSE: Over the past several years, alternative imaging techniques including electroanatomic mapping systems such as CARTO®3 (C3) have been developed to improve anatomic resolution and potentially limit radiation exposure in electrophysiology (EP) procedures. We retrospectively examined the effect of the introduction of C3 on patient radiation exposure during EP studies and ablation procedures at a children's hospital. METHODS: All patients that underwent EP and ablation procedures between January 2012 and August 2015 were included; demographic information, fluoroscopy time (FT), total radiation dose (RAD), and dose-area product (DAP) were collected. Patients were stratified by time period (before vs. after C3 introduction) in three groups: (1) normal heart, (2) congenital heart disease (CHD), and (3) those requiring trans-septal (TS) access. The normal heart group was further separated by arrhythmia diagnosis (accessory pathway (AP), AV nodal reentry tachycardia (AVNRT), atrial, or ventricular arrhythmia). Mean values were compared using a single sample t test, as well as analysis of covariance to control for age, weight, and arrhythmia diagnosis. RESULTS: Mean FT decreased after introduction of C3 in patients in all three patient groups (p < 0.01). When separated by arrhythmia diagnosis, FT decreased in the AP and AVNRT groups (p < 0.0001). After controlling for age, weight, and arrhythmia diagnosis, there was a statistically significant decrease in FT in all three groups and in both RAD and DAP in the normal heart group. Zero fluoroscopy was achieved in 50/159 (31 %) and ≤1 min of FT in 71/159 (45 %) of cases. CONCLUSIONS: We have shown a significant decrease in multiple measures of radiation after introduction of C3. Continued refinements are needed to further decrease radiation utilization and achieve the goal of zero fluoroscopy.


Assuntos
Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/cirurgia , Mapeamento Potencial de Superfície Corporal/estatística & dados numéricos , Ablação por Cateter/estatística & dados numéricos , Fluoroscopia/estatística & dados numéricos , Exposição à Radiação/estatística & dados numéricos , Adolescente , Adulto , Arritmias Cardíacas/diagnóstico , Criança , Pré-Escolar , District of Columbia/epidemiologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Prevalência , Doses de Radiação , Exposição à Radiação/prevenção & controle , Proteção Radiológica , Estudos Retrospectivos , Fatores de Risco , Cirurgia Assistida por Computador , Resultado do Tratamento , Adulto Jovem