1.
J Bone Joint Surg Am ; 106(11): 941-949, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38512965

RESUMO

BACKGROUND: Osseointegration is essential for the long-term survival of cementless femoral stems and is dependent on periprosthetic bone quality and correct implantation technique. The aim of this study was to evaluate the 3-dimensional long-term fixation patterns of, and bone microarchitecture around, cementless hip stems. METHODS: Four specimens with varying degrees of bone quality and fixation characteristics from body donors who had received Alloclassic Zweymüller hip stems during their lifetime (mean time in situ at the time of death: 12.73 years) were evaluated with use of radiographs, high-resolution computed tomography (CT) scans, and hard-tissue histology. The CT voxel size was 85 µm, and the following parameters were calculated: total bone volume, total bone volume fraction, trabecular bone volume, trabecular bone volume fraction, cortical bone volume, cortical bone volume fraction, and cortical thickness. Bone-implant contact and canal fill index values for each Gruen zone of the specimens were calculated with use of histological samples. RESULTS: Femoral stems with apparently good cortical contact on clinical radiographs showed higher values for cortical bone volume, trabecular bone volume, and cortical thickness in the high-resolution CT analysis than femoral stems with apparently weak cortical contact on clinical radiographs. Based on the histological evaluation, the mean bone-implant contact ranged from 22.94% to 57.24% and the mean canal fill index ranged from 52.33% to 69.67% among the specimens. CONCLUSIONS: This study demonstrated different osseointegration patterns of cementless femoral stems on the basis of radiographs, high-resolution CT scans, and histological evaluation. Femora with high cortical bone volume and cortical thickness were associated with higher canal fill indices, whereas femora with low cortical bone volume and cortical thickness had lower canal fill indices and showed a characteristic corner-anchorage pattern. CLINICAL RELEVANCE: Osseointegration patterns and thus the long-term survival of cementless femoral stems are dependent on cortical bone volume and cortical thickness.


Assuntos
Fêmur , Prótese de Quadril , Osseointegração , Tomografia Computadorizada por Raios X , Osseointegração/fisiologia , Humanos , Fêmur/diagnóstico por imagem , Masculino , Feminino , Idoso , Artroplastia de Quadril/métodos , Pessoa de Meia-Idade , Desenho de Prótese , Imageamento Tridimensional
2.
Orthop Traumatol Surg Res ; 110(1): 103594, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36921758

RESUMO

BACKGROUND: Fractures to the fifth's metatarsal (MT-V) diaphysis are common. These are inconsistently referred to as diaphyseal-, shaft-, or Dancer's fractures. A comprehensive analysis of the MT-V fracture morphology is missing. The aim was to qualitatively and quantitatively analyze fracture patterns of MT-V diaphyseal fractures. HYPOTHESIS: Fractures to the shaft of the fifth metatarsal feature specific fracture morphologies. MATERIALS AND METHODS: Retrospective, radiologic database study. Included were all acute, isolated MT-V shaft fractures (including the proximal [Lawrence and Botte (L&B) III] and distal meta-diaphysis). Demographics and fracture characteristics were assessed. Each proximal fracture line was drawn, scaled, and a qualitative and quantitative fracture line analysis was conducted. The quantitative fracture line analysis aimed at identifying dens clusters with arbitrary shape using the DBSCAN algorithm. Data are presented as mean±standard deviation. RESULTS: Out of 704 eligible MT-V fractures, 156 met the inclusion criteria. Patient's mean age was 46±19 years and 94% suffered a low energy trauma. Qualitative and quantitative fracture line analysis revealed three distinct fracture patterns. The proximal (30%) and distal (5%) meta-diaphyseal clusters showed a predominant transverse fracture pattern. The vast majority of diaphyseal fractures (56%) were spiral/oblique fractures, progressing from the proximal lateral meta-diaphyseal region in an oblique course at 61±9° to the medial distal diaphyseal cortex. Seven percent of diaphyseal fractures showed a transverse fracture pattern. DISCUSSION: Based on a qualitative and quantitative analysis of all MT-V shaft fractures, three distinct fracture clusters were identified with homogeneous fracture patterns. MT-V shaft fractures should therefore be classified as proximal meta-diaphyseal (L&B Type III), diaphyseal (oblique or transverse) and distal meta-diaphyseal. LEVEL OF PROOF: IV; retrospective database study.


Assuntos
Traumatismos do Pé , Fraturas Ósseas , Ossos do Metatarso , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Ossos do Metatarso/diagnóstico por imagem , Estudos Retrospectivos , Diáfises/diagnóstico por imagem , Diáfises/lesões ,
3.
J Mech Behav Biomed Mater ; 138: 105631, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36592570

RESUMO

Digital volume correlation (DVC) enables to evaluate the ability of µFE models in predicting experimental results on the mesoscale. In this study predicted displacement fields of three different linear and materially nonlinear µFE simulation methods were compared to DVC measured displacement fields at specific load steps in the elastic regime (StepEl) and after yield (StepUlt). Five human trabecular bone biopsies from a previous study were compressed in several displacement steps until failure. At every compression step, µCT images (resolution: 36 µm) were recorded. A global DVC algorithm was applied to compute the displacement fields at all loading steps. The unloaded 3D images were then used to generate homogeneous, isotropic, linear and materially nonlinear µFE models. Three different µFE simulation methods were used: linear (L), nonlinear (NL), and nonlinear stepwise (NLS). Regarding L and NL, the boundary conditions were derived from the interpolated displacement fields at StepEl and StepUlt, while for the NLS method nonlinear changes of the boundary conditions of the experiments were captured using the DVC displacement field of every available load step until StepEl and StepUlt. The predicted displacement fields of all µFE simulation methods were in good agreement with the DVC measured displacement fields (individual specimens: R2>0.83 at StepEl and R2>0.59 at StepUlt; pooled data: R2>0.97 at StepEl and R2>0.92 at StepUlt). At StepEl, all three simulation methods showed similar intercepts, slopes, and coefficients of determination while the nonlinear µFE models improved the prediction of the displacement fields slightly in all Cartesian directions at StepUlt (individual specimens: L: R2>0.59 and NL, NLS: R2>0.68; pooled data: L: R2>0.92 and NL, NLS: R2>0.94). Damaged/overstrained elements in L, NL, and NLS occurred at similar locations but the number of overstrained elements was overestimated when using the L simulation method. Considering the increased solving time of the nonlinear µFE models as well as the acceptable performance in displacement prediction of the linear µFE models, one can conclude that for similar use cases linear µFE models represent the best compromise between computational effort and accuracy of the displacement field predictions.


Assuntos
Osso Esponjoso , Humanos , Fenômenos Biomecânicos , Análise de Elementos Finitos , Estresse Mecânico , Biópsia , Microtomografia por Raio-X
4.
J Orthop Res ; 41(8): 1774-1780, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36694475

RESUMO

Recently, promising results have been reported for detection of osteoporosis with use of an aluminum phantom. Therefore, the aim of this study was to evaluate the feasibility of radiography-based bone mineral density (BMD) measurement using a graded aluminum phantom. This study included 27 postmenopausal women with a distal radius fracture. Aluminum phantom radiography of the healthy radius was conducted as well as high-resolution peripheral quantitative computed tomography (HR-pQCT) measurement of the ultradistal radius and dual energy X-ray absorptiometry (DXA) of the radius, spine, and hip. A strong correlation was observed between aluminum phantom radiography-based mean gray value (mGV) and DXA-derived BMD, especially for the ultradistal radius (ρ = 0.75; p < 0.001). A moderate correlation for the femoral neck (ρ = 0.61 and p < 0.001) between modalities was found. Radius mGV and HR-pQCT-derived BMD only showed a moderate correlation (ρ = 0.48; p < 0.09). Aluminum phantom radiography might serve as a cost efficient, highly available, low-radiation dose screening, and diagnostic method for osteoporosis additively to DXA measurements. Especially, an application in areas with constrained DXA availability and such as preoperative trauma settings would be beneficial. However, further investigation and assessment of specificity and sensitivity is needed.


Assuntos
Fraturas Ósseas , Osteoporose Pós-Menopausa , Osteoporose , Feminino , Humanos , Absorciometria de Fóton/métodos , Rádio (Anatomia)/diagnóstico por imagem , Alumínio , Pós-Menopausa , Estudos de Viabilidade , Osteoporose/diagnóstico por imagem , Densidade Óssea , Osteoporose Pós-Menopausa/complicações , Osteoporose Pós-Menopausa/diagnóstico por imagem
5.
Sensors (Basel) ; 21(18)2021 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-34577474

RESUMO

BACKGROUND: The preparation of bone for the insertion of an osseointegrated transfemoral implant and the insertion process are performed at very low speeds in order to avoid thermal damages to bone tissue which may potentially jeopardize implant stability. The aim of this study was to quantify the temperature increase in the femur at different sites and insertion depths, relative to the final implant position during the stepwise implantation procedure. METHODS: The procedure for installation of the osseointegrated implant was performed on 24 femoral specimens. In one specimen of each pair, the surgery was performed at the clinically practiced speed, while the speed was doubled in the contralateral specimen. Six 0.075 mm K fine gauge thermocouples (RS Components, Sorby, UK) were inserted into the specimen at a distance of 0.5 mm from the final implant surface, and six were inserted at a distance of 1.0 mm. RESULTS: Drilling caused a temperature increase of <2.5 °C and was not statistically significantly different for most drill sizes (0.002 < p < 0.845). The mean increase in temperature during thread tapping and implant insertion was <5.0 °C, whereas the speed had an effect on the temperature increase during thread tapping. CONCLUSIONS: Drilling is the most time-consuming part of the surgery. Doubling the clinically practiced speed did not generate more heat during this step, suggesting the speed and thus the time- and cost-effectiveness of the procedure could be increased. The frequent withdrawal of the instruments and removal of the bone chips is beneficial to prevent temperature peaks, especially during thread tapping.


Assuntos
Prótese Ancorada no Osso , Implantes Dentários , Temperatura Corporal , Osso e Ossos , Temperatura Alta , Temperatura , Termômetros
6.
Sci Rep ; 9(1): 10305, 2019 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-31311994

RESUMO

Predicting pathologic fractures in femora with metastatic lesions remains a clinical challenge. Currently used guidelines are inaccurate, especially to predict non-impeding fractures. This study evaluated the ability of a nonlinear quantitative computed tomography (QCT)-based homogenized voxel finite element (hvFE) model to predict patient-specific pathologic fractures. The hvFE model was generated highly automated from QCT images of human femora. The femora were previously loaded in a one-legged stance setup in order to assess stiffness, failure load, and fracture location. One femur of each pair was tested in its intact state, while the contralateral femur included a simulated lesion on either the superolateral- or the inferomedial femoral neck. The hvFE model predictions of the stiffness (0.47 < R2 < 0.94), failure load (0.77 < R2 < 0.98), and exact fracture location (68%) were in good agreement with the experimental data. However, the model underestimated the failure load by a factor of two. The hvFE models predicted significant differences in stiffness and failure load for femora with superolateral- and inferomedial lesions. In contrast, standard clinical guidelines predicted identical fracture risk for both lesion sites. This study showed that the subject-specific QCT-based hvFE model could predict the effect of metastatic lesions on the biomechanical behaviour of the proximal femur with moderate computational time and high level of automation and could support treatment strategy in patients with metastatic bone disease.


Assuntos
Neoplasias Ósseas/secundário , Fraturas do Fêmur/diagnóstico por imagem , Fraturas Espontâneas/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/complicações , Neoplasias Ósseas/diagnóstico por imagem , Feminino , Fraturas do Fêmur/etiologia , Análise de Elementos Finitos , Fraturas Espontâneas/etiologia , Humanos , Masculino , Modelagem Computacional Específica para o Paciente , Tomografia Computadorizada por Raios X
7.
J Orthop Res ; 35(11): 2407-2414, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28240373

RESUMO

Pathologic fractures of femora in patients with metastatic cancer are associated with high morbidity and mortality. Prediction of impending fractures is based on unspecific clinical criteria or past clinician's experience, which leads to underestimation or overtreatment. The aim of this study was to investigate the effect of the site of metastatic lesions on biomechanical behavior of the proximal femur. Sixteen pairs of human femora were scanned with quantitative computed tomography (QCT) to asses bone mineral density. One femur of each pair remained intact while a defined lesion was reamed out in either the superolateral or inferomedial portion of the femoral neck of the contralateral femur. All femora were loaded in a mechanical test setup mimicking one-legged stance and stiffness, failure load, and fracture location were determined. In the biomechanical experiments the superolateral lesion and the inferomedial lesion caused a stiffness reduction of 19% and 66%, respectively. The average failure load was 40% and 75% lower for specimens with the superolateral (4.53 ± 1.56 kN) and inferomedial (1.89 ± 1.73 kN) lesions, respectively, compared to intact specimens (7.66 ± 3.34 kN). Lesions in the femoral neck led to reduction in both stiffness and failure load of the proximal femur. Furthermore, the site of the lesion had a large effect on the magnitude of the reduction in biomechanical properties. The presented data emphasize the importance of differentiating between locations of the lesion in pathologic fracture prediction of the metastatic femur and underline the insufficient accuracy of current predictive guidelines. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2407-2414, 2017.


Assuntos
Neoplasias Ósseas/complicações , Fraturas do Colo Femoral/etiologia , Fêmur/fisiopatologia , Osteólise/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/etiologia
8.
J Orthop Surg Res ; 10: 139, 2015 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-26351239

RESUMO

BACKGROUND: Extensor tendon irritation is one of the most common complications following volar locking plate osteosynthesis (VLPO) for distal radius fractures. It is most likely caused by distal screws protruding the dorsal cortex. Shorter distal screws could avoid this, yet the influence of distal screw length on the primary stability in VLPO is unknown. The aim of this study was to compare 75 to 100% distal screw lengths in VLPO. METHODS: A biomechanical study was conducted on 11 paired fresh-frozen radii. HRpQCT scans were performed to assess bone mineral density (BMD) and bone mineral content (BMC). The specimens were randomized pair-wise into two groups: 100% (group A) and 75% (group B) unicortical distal screw lengths. A validated fracture model for extra-articular distal radius fractures (AO-23 A3) was used. Polyaxial volar locking plates were mounted, and distal screws was inserted using a drill guide block. For group A, the distal screw tips were intended to be flush or just short of the dorsal cortex. In group B, a target screw length of 75% was calculated. The specimens were tested to failure using a displacement-controlled axial compression test. Primary biomechanical stability was assessed by stiffness, elastic limit, and maximum force as well as with residual tilt, which quantified plastic deformation. RESULTS: Nine specimens were tested successfully. BMD and BMC did not differ between the two groups. The mean distal screw length of group A was 21.7 ± 2.6 mm (range: 16 to 26 mm), for group B 16.9 ± 1.9 mm (range: 12 to 20 mm). Distal screws in group B were on average 5.6 ± 0.9 mm (range: 3 to 7 mm) shorter than measured. No significant differences were found for stiffness (706 ± 103 N/mm vs. 660 ± 124 N/mm), elastic limit (177 ± 25 N vs. 167 ± 36 N), maximum force (493 ± 139 N vs. 471 ± 149 N), or residual tilt (7.3° ± 0.7° vs. 7.1° ± 1.3°). CONCLUSION: The 75% distal screw length in VLPO provides similar primary stability to 100% unicortical screw length. This study, for the first time, provides the biomechanical basis to choose distal screws significantly shorter then measured.


Assuntos
Fenômenos Biomecânicos/fisiologia , Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas do Rádio/patologia , Fraturas do Rádio/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino