1.
Bioanalysis ; 2022 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-35255714

RESUMO

Background: The capability of targeted MS-based methods to simultaneously measure multiple analytes with high selectivity and sensitivity greatly facilitates the discovery and quantitation of novel biomarkers. However, the complexity of biological samples is a major bottleneck that requires extensive sample preparation. Results: This paper reports a generic workflow to optimize surrogate peptide-based protein biomarker screening for seven human proteins in a multiplexed manner without the need for any specific affinity reagents. Each step of the sample processing and LC-MS methods is systematically assessed and optimized for better analytical performance. Conclusion: The established method is used for the screening of multiple myeloma patient samples to determine which proteins could be robustly measured and serve as potential biomarkers of the disease.

2.
Sci Rep ; 10(1): 22155, 2020 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-33335114

RESUMO

Arginine methylation has been recognized as a post-translational modification with pleiotropic effects that span from regulation of transcription to metabolic processes that contribute to aberrant cell proliferation and tumorigenesis. This has brought significant attention to the development of therapeutic strategies aimed at blocking the activity of protein arginine methyltransferases (PRMTs), which catalyze the formation of various methylated arginine products on a wide variety of cellular substrates. GSK3368715 is a small molecule inhibitor of type I PRMTs currently in clinical development. Here, we evaluate the effect of type I PRMT inhibition on arginine methylation in normal human peripheral blood mononuclear cells and utilize a broad proteomic approach to identify type I PRMT substrates. This work identified heterogenous nuclear ribonucleoprotein A1 (hnRNP-A1) as a pharmacodynamic biomarker of type I PRMT inhibition. Utilizing targeted mass spectrometry (MS), methods were developed to detect and quantitate changes in methylation of specific arginine residues on hnRNP-A1. This resulted in the development and validation of novel MS and immune assays useful for the assessment of GSK3368715 induced pharmacodynamic effects in blood and tumors that can be applied to GSK3368715 clinical trials.


Assuntos
Antineoplásicos/farmacocinética , Biomarcadores , Ribonucleoproteína Nuclear Heterogênea A1/metabolismo , Proteína-Arginina N-Metiltransferases/antagonistas & inibidores , Proteínas Repressoras/antagonistas & inibidores , Animais , Antineoplásicos/uso terapêutico , Antineoplásicos Imunológicos/química , Antineoplásicos Imunológicos/farmacocinética , Antineoplásicos Imunológicos/farmacologia , Arginina/metabolismo , Células Cultivadas , Cromatografia Líquida , Monitoramento de Medicamentos , Ativação Enzimática , Inibidores Enzimáticos/farmacocinética , Inibidores Enzimáticos/uso terapêutico , Regulação Neoplásica da Expressão Gênica/efeitos dos fármacos , Ribonucleoproteína Nuclear Heterogênea A1/sangue , Humanos , Leucócitos Mononucleares/efeitos dos fármacos , Leucócitos Mononucleares/metabolismo , Espectrometria de Massas , Metilação , Camundongos , Terapia de Alvo Molecular , Neoplasias/sangue , Neoplasias/tratamento farmacológico , Neoplasias/metabolismo , Proteína-Arginina N-Metiltransferases/genética , Proteínas Repressoras/genética , Especificidade por Substrato
3.
Bioanalysis ; 11(13): 1275-1289, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31298556

RESUMO

Aim: Recent advances in microflow ultra performance liquid chromatography (UPLC) systems offer higher sensitivity with robustness to meet the routine bioanalytical demands. Modern high-resolution mass spectrometers (HRMS) enable the development of highly selective methods with broad dynamic range. Results: The quantitative performances of tandem quadrupole MS and HRMS were comprehensively compared using seven intact peptide hormones up to 9.4 kDa. Results show comparable performance between two platforms in sensitivity, accuracy and linearity. For some peptides, HRMS provided lower background interference. The benefit of increased sensitivity using microflow UPLC was also demonstrated. Conclusion: HRMS is a versatile platform capable of both basic characterization and reliable quantitation in complex matrices. Microflow UPLC provides lower LLOQs than conventional flow systems, even with less sample volume injected.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Hormônios Peptídicos/análise , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Cromatografia Líquida de Alta Pressão/normas , Limite de Detecção , Hormônios Peptídicos/isolamento & purificação , Hormônios Peptídicos/normas , Controle de Qualidade , Reprodutibilidade dos Testes , Extração em Fase Sólida , Espectrometria de Massas em Tandem/normas
4.
Bioanalysis ; 8(3): 169-77, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26795399

RESUMO

BACKGROUND: For quantitative bioanalysis utilizing MS, the instrument of choice is typically a triple quadruple mass spectrometer. However, advances in high-resolution MS have allowed sensitivity and dynamic ranges to approach that of triple quadrupole instruments. RESULTS: A matrix-free protein digest, a digested therapeutic protein and the intact peptide therapeutic liraglutide were each analyzed on high-resolution and triple quadrupole mass spectrometers with data compared. Samples from a mouse PK study with liraglutide were analyzed using the two different instruments, and equivalent PK exposure data were demonstrated. CONCLUSION: High-resolution and triple quadrupole mass spectrometers can generate data resulting in identical PK parameters from an in-life sample set, thus giving confidence in either technique in support of biotherapeutic PK exposure studies.


Assuntos
Espectrometria de Massas/métodos , Peptídeos/análise , Preparações Farmacêuticas/análise , Animais , Feminino , Limite de Detecção , Masculino , Espectrometria de Massas/instrumentação , Camundongos , Peptídeos/química , Preparações Farmacêuticas/química , Distribuição Tecidual
5.
Bioanalysis ; 4(5): 605-15, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22409557

RESUMO

BACKGROUND: The quantification of proteins and peptides in in vivo samples is a critical part of supporting the drug development process for biotherapeutics. LC-MS/MS using tandem quadrupole mass spectrometers is well established as the technology of choice for the quantification of small-molecule drugs and their metabolites in biological fluid. The application of accurate mass MS for quantification in a DMPK environment has attracted considerable interest in recent years. MATERIALS & METHODS: In this article we describe and compare the application of LC-high-resolution MS and LC-selected reaction monitoring (SRM) for the quantification of a therapeutics proteins. RESULTS: The accurate mass instrumentation showed acceptable linearity and sensitivity to quantify the protein therapeutic to the level of 10 ng/ml. The accurate mass instrument was operated in accurate mass SRM using high resolution (SRM-HR), the assay was demonstrated to be linear over three orders of magnitude. By narrowing the mass window from 100 mDa to 40 mDa and then to 20 mDa the assay specificity was significantly improved, hence increasing the S/N and improving the assay sensitivity. CONCLUSION: The high-resolution instrument was demonstrated to be reproducible over the course of the assay. The accurate mass method sensitivity was determined to be within one order of magnitude of that obtained with a tandem quadrupole MS/MS assay.


Assuntos
Espectrometria de Massas , Peptídeos/química , Preparações Farmacêuticas/química , Cromatografia Líquida , Peptídeos/análise , Preparações Farmacêuticas/análise , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA