Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
J Ophthalmol ; 2024: 6653621, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38827421

RESUMO

Purpose: Our study aimed to evaluate the indications and outcomes of intraocular lens (IOL) explantation surgeries in a tertiary eyecare center in Hungary. Materials and Methods: This retrospective study included all IOL explantation surgeries performed between 2006 and 2020 at the Department of Ophthalmology of Semmelweis University, Budapest, Hungary. There were no exclusion criteria for this study. For each patient, the demographics, clinical history, preoperative status, indications for IOL explantation, and operative and postoperative details were reviewed. Primary outcomes included explantation indications and the type of secondary implanted IOL. Results: A total of 161 eyes from 153 patients were included (96 males; 62.7%); age at the time of the IOL explantation was 65.0 ± 17.4 years. The mean time between primary cataract surgery and IOL explantation was 8.5 ± 7.7 years. In total, 139 (86.3%) PCIOLs and 22 (13.7%) ACIOLs were explanted. The main indications for IOL explantation were dislocation (n = 133; 95.7%) and refractive cause (n = 2; 1.4%) in the PCIOL group. Among ACIOL explantations, the main reasons were pseudophakic bullous keratopathy (n = 14; 63.6%), dislocation (n = 4; 18.2%), and refractive cause (n = 2; 9.1%). In the PCIOL group, 115 (82.7%) primary IOLs were implanted in the capsular bag, 16 (11.5%) were sulcus fixated, and 8 (5.8%) were scleral fixated. The most frequent ocular comorbidities were previous vitrectomy (n = 50, 31.1%), previous ocular trauma (n = 45, 28.0%), glaucoma (n = 16, 9.9%), pseudoexfoliation syndrome (n = 15, 9.3%), and high axial myopia (n = 14, 8.7%). The most commonly used secondary IOL implant was the prepupillary iris-claw IOL (n = 115, 73.7%), followed by the retropupillary iris-claw IOL (n = 32, 20.5%). Uncorrected visual acuity (UCVA) was significantly better following IOL exchange in the entire sample (1.57 ± 0.61 (range: 2.40-0.05) vs. 0.77 ± 0.56 (range: 2.40-0.00); p < 0.001). Best-corrected visual acuity (BCVA) was maintained or improved in 80.7% of cases after IOL explantation. Conclusions: The most common indication for IOL explantation at a tertiary eyecare center in Hungary is IOL dislocation, followed by pseudophakic bullous keratopathy. Prepupillary and retropupillary iris-claw IOL are the most frequently used secondary implants and their use resulted in a significant UCVA improvement following IOL exchange.

2.
PLoS One ; 19(4): e0300576, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640111

RESUMO

PURPOSE: The purpose of this study was to investigate the effect of the corneal back surface by comparing the keratometric astigmatism (K, derived from the corneal front surface) of a modern optical biometer against astigmatism of Total Keratometry (TK, derived from both corneal surfaces) in a large population with cataractous eyes. The results were then used to define linear prediction models to map K to TK. METHODS: From a large dataset containing bilateral biometric measurements (IOLMaster 700) in 9736 patients prior to cataract surgery, the total corneal astigmatism was decomposed into vectors for K, corneal back surface (BS), and TK. A multivariate prediction model (MV), simplified model with separation of vector components (SM) and a constant model (CM) were defined to map K to TK vector components. RESULTS: The K centroid (X/Y) showed some astigmatism with-the-rule (0.1981/-0.0211 dioptre (dpt)) whereas the TK centroid was located around zero (-0.0071/-0.0381 dpt against-the-rule) and the BS centroid showed systematic astigmatism against-the-rule (-0.2367/-0.0145 dpt). The respective TK-K centroid was located at -0.2052/-0.0302 dpt. The MV model showed the same performance (i.e. mean absolute residuum) as the SM did (0.1098 and 0.1099 dpt respectively) while the CM performed only slightly worse (0.1121 dpt mean absolute residuum). CONCLUSION: In cases where tomographic data are unavailable statistical models could be used to consider the overall contribution of the back surface to the total corneal astigmatism. Since the performance of the CM is sufficiently close to that of MV and SM we recommend using the CM which can be directly considered e.g. as surgically induced astigmatism.


Assuntos
Astigmatismo , Extração de Catarata , Doenças da Córnea , Humanos , Astigmatismo/diagnóstico , Biometria/métodos , Córnea/diagnóstico por imagem
3.
Acta Ophthalmol ; 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38687054

RESUMO

PURPOSE: To investigate the performance of a simple prediction scheme for the formula constants optimised for a mean refractive prediction error. METHODS: Analysis based on a dataset of 888 eyes before and after cataract surgery with IOL implantation (Hoya Vivinex). IOLMaster 700 biometric data, power of the implanted lens and postoperative spherical equivalent refraction were used to calculate the optimised constants (.)opt for SRKT, HofferQ, Holladay and Haigis formula with an iterative nonlinear optimisation. For detuning start values by ±1.5 from (.)opt, the predicted formula constants (.)pred were calculated and compared with (.)opt. Formula performance metrics mean (MPE), median (MEDPE), mean absolute (MAPE), median absolute (MEDAPE), root mean squared (RMSPE) and standard deviation (SDPE) of the formula prediction error were analysed for (.)opt and (.)pred. RESULTS: (.)pred - (.)opt showed a 2nd order parabolic behaviour with maximal deviations up to 0.09 at the tails of detuning and a minimal deviation up to -0.01 for all formulae. The performance curves of different metrics of PE as functions of detuning variations show that the formula constants for zeroing MPE and MEDPE yield almost identical formula constants, optimisation for MAPE, MEDAPE and RMSPE yielded formula constants very close to (.)opt, and optimisation for SDPE could result in formula constants up to 0.5 off (.)opt which is unacceptable for clinical use. CONCLUSION: This simple prediction scheme for formula constant optimisation for zero mean refraction error performs excellently in our monocentric dataset, even for larger deviations of the start value from (.)opt. Further studies with multicentric data and larger sample sizes are required to investigate the performance in a clinical setting further.

4.
Ophthalmol Ther ; 13(5): 1343-1356, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38507192

RESUMO

INTRODUCTION: This study analysed the causative factors and clinical characteristics of acute and chronic ocular sequelae of Stevens-Johnson syndrome and toxic epidermal necrolysis (SJS/TEN) treated at a large third-referral centre in a developed country (Hungary) over a 15-year period. METHODS: This was a retrospective review of patients with acute and/or chronic SJS/TEN who were managed between 2006 and 2020 at the Department of Ophthalmology of Semmelweis University in Budapest, Hungary. For each subject, clinical data, including patient demographics, clinical history, causative agents of SJS/TEN, and conservative and surgical treatment details, were reviewed. RESULTS: Ninety-six eyes of 48 patients were included (28 female; 58.3%); the age at disease onset was 32.1 ± 22.4 years. The most common causative factors were medicines (n = 36; 75.0%). Among these drugs, 29.2% were nonsteroidal anti-inflammatory drugs (NSAIDs) (n = 14), 20.8% were antibiotics (n = 10) and 14.6% were antiepileptic drugs (n = 7). In patients with chronic SJS/TEN, the most commonly found ocular sequelae were conjunctival hyperaemia in 45 (56.3%) eyes, symblepharon in 38 (47.5%) eyes, trichiasis/distichiasis in 37 (46.3%) eyes, corneal neovascularization in 31 (38.8%) eyes and corneal scarring in 29 (36.3%) eyes. In patients with chronic SJS/TEN, the most frequently used topical conservative treatment included antibiotics in 53 (66.3%) eyes, preservative-free artificial tears in 50 (62.5%) eyes and topical corticosteroids in 42 (52.5%) eyes of 40 patients. The most frequently performed ocular surgeries for managing chronic ocular sequelae in patients with SJS/TEN were epilation for trichiasis (n = 27; 33.8%), cataract surgery (n = 14; 17.5%), entropion surgery (n = 12; 15.0%), penetrating keratoplasty (PK) (n = 11; 13.8%) and amniotic membrane transplantation (n = 4; 5.0%). CONCLUSION: Our results suggest that NSAIDs, antibiotics and antiepileptic drugs are the most common causative factors for SJS/TEN in Hungary. Like in other countries, in Hungary, the ocular management of patients with acute and chronic SJS/TEN is heterogeneous, and most cases do not follow modern therapeutic guidelines.

5.
PLoS One ; 19(2): e0297869, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38330090

RESUMO

PURPOSE: The purpose of this study was to investigate the repeatability of biometric measures and also to assess the interactions between the uncertainties in these measures for use in an error propagation model, using data from a large patient cohort. METHODS: In this cross-sectional non-randomised study we evaluated a dataset containing 3379 IOLMaster 700 biometric measurements taken prior to cataract surgery. Only complete scans with at least 3 successful measurements for each eye performed on the same day were considered. The mean (Mean) and standard deviations (SD) for each sequence of measurements were derived and analysed. Correlations between the uncertainties were assessed using Spearman rank correlations. RESULTS: In the dataset with 677 eyes matching the inclusion criteria, the within subject standard deviation and repeatability for all parameters match previously published data. The SD of the axial length (AL) increased with the Mean AL, but there was no noticeable dependency of the SD of any of the other parameters on their corresponding Mean value. The SDs of the parameters are not independent of one another, and in particular we observe correlations between those for AL, anterior chamber depth, aqueous depth, lens thickness and corneal thickness. CONCLUSIONS: The SD change over Mean for AL measurement and the correlations between the uncertainties of several biometric parameters mean that a simple Gaussian error propagation model cannot be used to derive the effect of biometric uncertainties on the predicted intraocular lens power and refraction after cataract surgery.


Assuntos
Catarata , Lentes Intraoculares , Humanos , Estudos Transversais , Comprimento Axial do Olho , Estudos Prospectivos , Biometria , Câmara Anterior/diagnóstico por imagem
6.
Acta Ophthalmol ; 102(3): e285-e295, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37350286

RESUMO

PURPOSE: The purpose of this study was to investigate the uncertainty in the formula predicted refractive outcome REFU after cataract surgery resulting from measurement uncertainties in modern optical biometers using literature data for within-subject standard deviation Sw. METHODS: This Monte-Carlo simulation study used a large dataset containing 16 667 preoperative IOLMaster 700 biometric measurements. Based on literature Sw values, REFU was derived for both the Haigis and Castrop formulae using error propagation strategies. Using the Hoya Vivinex lens (IOL) as an example, REFU was calculated both with (WLT) and without (WoLT) consideration of IOL power labelling tolerances. RESULTS: WoLT the median REFU was 0.10/0.12 dpt for the Haigis/Castrop formula, and WLT it was 0.13/0.15 dpt. WoLT REFU increased systematically for short eyes (or high power IOLs), and WLT this effect was even more pronounced because of increased labelling tolerances. WoLT the uncertainty in the measurement of the corneal front surface radius showed the largest contribution to REFU, especially in long eyes (and low power IOLs). WLT the IOL power uncertainty dominated in short eyes (or high power IOLs) and the uncertainty of the corneal front surface in long eyes (or low power IOLs). CONCLUSIONS: Compared with published data on the formula prediction error of refractive outcome after cataract surgery, the uncertainty of biometric measures seems to contribute with ⅓ to ½ to the entire standard deviation. REFU systematically increases with IOL power and decreases with axial length.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Acuidade Visual , Implante de Lente Intraocular , Incerteza , Refração Ocular , Biometria/métodos , Estudos Retrospectivos , Óptica e Fotônica
7.
Curr Eye Res ; 49(2): 150-157, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37921272

RESUMO

PURPOSE: To investigate collagen I, collagen V, nuclear factor kappa-light-chain-enhancer of activated B cells (NF-κB), lysyl oxidase (LOX), transforming growth factor ß1 (TGF-ß1) and interleukin-6 (IL-6) expression in healthy and keratoconus human corneal fibroblasts (HCFs and KC-HCFs), 24 h after Rose Bengal photodynamic therapy (RB-PDT). METHODS: HCFs were isolated from healthy human corneal donors (n = 5) and KC-HCFs from elective penetrating keratoplasties (n = 5). Both cell cultures underwent RB-PDT (0.001% RB concentration, 0.17 J/cm2 fluence) and 24 h later collagen I, collagen V, NF-κB, LOX, TGF-ß1 and IL-6 mRNA and protein expression have been determined using qPCR and Western blot, IL-6 concentration in the cell culture supernatant by ELISA. RESULTS: TGF-ß1 mRNA expression was significantly lower (p = 0.02) and IL-6 mRNA expression was significantly higher in RB-PDT treated HCFs (p = 0.01), than in HCF controls. COL1A1, COL5A1 and TGF-ß1 mRNA expression was significantly lower (p = 0.04; p = 0.02 and p = 0.003) and IL-6 mRNA expression was significantly higher (p = 0.02) in treated KC-HCFs, than in KC-HCF controls. TGF-ß1 protein expression in treated HCFs was significantly higher than in HCF controls (p = 0.04). IL-6 protein concentration in the HCF and KC-HCF culture supernatant after RB-PDT was significantly higher than in controls (p = 0.02; p = 0.01). No other analyzed mRNA and protein expression differed significantly between the RB-PDT treated and untreated groups. CONCLUSIONS: Our study demonstrates that RB-PDT reduces collagen I, collagen V and TGF-ß1 mRNA expression, while increasing IL-6 mRNA and protein expression in KC-HCFs. In HCFs, RB-PDT increases TGF-ß1 and IL-6 protein level after 24 h.


Assuntos
Interleucina-6 , Fator de Crescimento Transformador beta , Humanos , Fator de Crescimento Transformador beta/metabolismo , Fator de Crescimento Transformador beta/farmacologia , Interleucina-6/genética , Interleucina-6/metabolismo , NF-kappa B/genética , NF-kappa B/metabolismo , Rosa Bengala/farmacologia , Fator de Crescimento Transformador beta1/farmacologia , Proteína-Lisina 6-Oxidase/metabolismo , Colágeno/metabolismo , Colágeno Tipo I/genética , Colágeno Tipo I/metabolismo , Fibroblastos/metabolismo , RNA Mensageiro/genética , RNA Mensageiro/metabolismo
8.
J Cataract Refract Surg ; 50(3): 201-208, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37847110

RESUMO

PURPOSE: To investigate the effect of formula constants on predicted refraction and limitations of constant optimization for classical and modern intraocular lens (IOL) power calculation formulae. SETTING: Tertiary care center. DESIGN: Retrospective single-center consecutive case series. METHODS: This analysis is based on a dataset of 888 eyes before and after cataract surgery with IOL implantation (Hoya Vivinex). Spherical equivalent refraction predSEQ was predicted using IOLMaster 700 data, IOL power, and formula constants from IOLCon ( https://iolcon.org ). The formula prediction error (PE) was derived as predSEQ minus achieved spherical equivalent refraction for the SRKT, Hoffer Q, Holladay, Haigis, and Castrop formulae. The gradient of predSEQ (gradSEQ) as a measure for the effect of the constants on refraction was calculated and used for constant optimization. RESULTS: Using initial formula constants, the mean PE was -0.1782 ± 0.4450, -0.1814 ± 0.4159, -0.1702 ± 0.4207, -0.1211 ± 0.3740, and -0.1912 ± 0.3449 diopters (D) for the SRKT, Hoffer Q, Holladay, Haigis, and Castrop formulas, respectively. gradSEQ for all formula constants (except gradSEQ for the Castrop R) decay with axial length because of interaction with the effective lens position (ELP). Constant optimization for a zero mean PE (SD: 0.4410, 0.4307, 0.4272, 0.3742, 0.3436 D) results in a change in the PE trend over axial length in all formulae where the constant acts directly on the ELP. CONCLUSIONS: With IOL power calculation formulae where the constant(s) act directly on the ELP, a change in constant(s) always changes the trend of the PE according to gradSEQ. Formulae where at least 1 constant does not act on the ELP have more flexibility to zero the mean or median PE without coupling with a PE trend error over axial length.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Acuidade Visual , Estudos Retrospectivos , Biometria/métodos , Refração Ocular , Óptica e Fotônica , Comprimento Axial do Olho
9.
Graefes Arch Clin Exp Ophthalmol ; 262(3): 879-889, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37682334

RESUMO

PURPOSE: To provide insights into morphologic and functional features of eyes with complicated Descemet's membrane detachment (DMD) and report clinical outcomes after surgical intervention. METHODS: Retrospective study of 18 eyes with complicated DMD between 2010 and 2022. Complicated DMD was defined if any of the following criteria applied: prior penetrating keratoplasty (PKP), corneal thinning, total DMD or persistent DMD after Air/Gas-Descemetopexy. Causes, surgical management, and clinical outcomes were analyzed. Scheimpflug tomography, anterior segment optical coherence tomography (AS-OCT) and histologic examination were performed to characterize corneas with DMD. RESULTS: Fourteen eyes with prior PKP developed spontaneous DMD after 24.2 ± 12.9 years (range = 18 months - 47 years, median = 25.7 years). Complicated DMD without prior PKP was associated in three eyes after cataract surgery and in one eye after infectious keratitis. In cases with previous PKP, AS-OCT demonstrated rupture of Descemet's membrane (DM) in five eyes and spontaneous reattachment was found in four eyes within 8 weeks of initial diagnosis, with no rupture of DM in any of the cases. There was no rupture of DM in corneas without previous PKP. After prior keratoplasty, definitive surgical treatment was repeat PKP in 13 eyes and Air/Gas-Descemetopexy in one eye. In corneas without prior keratoplasty, three eyes underwent PKP and one eye Air/Gas-Descemetopexy. Histological examination of two corneal explants revealed a severely thinned graft-host junction and a disrupted DM close to the graft-host junction. Visual acuity improved from 1.80 ± 0.58 logMAR to 0.75 ± 0.69 logMAR after prior PKP and from 1.45 ± 0.65 logMAR to 0.85 ± 1.13 logMAR without prior PKP. The postoperative course was uneventful in 16 of 18 eyes. CONCLUSION: PKP is an effective treatment option for complicated DMD, especially in ectatic corneas, whereas Air/Gas-Descemetopexy or Descemet Membrane Endothelial Keratoplasty do not address the primary issue of the curvature anomaly.


Assuntos
Transplante de Córnea , Lâmina Limitante Posterior , Humanos , Lâmina Limitante Posterior/cirurgia , Estudos Retrospectivos , Córnea , Ceratoplastia Penetrante
10.
J Cataract Refract Surg ; 50(4): 360-368, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37962174

RESUMO

PURPOSE: To investigate and compare different strategies of corneal power calculations using keratometry, paraxial thick lens calculations and ray tracing. SETTING: Tertiary care center. DESIGN: Retrospective single-center consecutive case series. METHODS: Using a dataset with 9780 eyes of 9780 patients from a cataractous population the corneal front (Ra/Qa) and back (Rp/Qp) surface radius/asphericity, central corneal thickness (CCT), and entrance pupil size (PUP) were recorded using the Casia 2 tomographer. Beside keratometry with the Zeiss (PK Z ) and Javal (PK J ) keratometer index, a thick lens paraxial formula (PG) and ray tracing (PR) was implemented to extract corneal power for pupil sizes from 2 mm to 5 mm in steps of 1 mm and PUP. RESULTS: With PUP PK Z /PK J overestimates the paraxial corneal power PG in around 97%/99% of cases and PR in around 80% to 85%/99%. PR is around 1/6 or 5/6 diopters (D) lower compared with PK Z or PK J . For a 2 mm pupil PR is around 0.20/0.91 D lower compared with PK Z /PK J and for a 5 mm pupil PR is comparable with PK Z (around 0.03 D lower) but around 0.70 to 0.75 D lower than PK J . CONCLUSIONS: "True" values of corneal power are mostly required in lens power calculations before cataract surgery, and overestimation of corneal power could induce trend errors in refractive outcome with axial length and lens power if compensated with the effective lens position.


Assuntos
Lentes Intraoculares , Humanos , Tomografia de Coerência Óptica , Estudos Retrospectivos , Reprodutibilidade dos Testes , Córnea , Refração Ocular , Biometria , Topografia da Córnea
11.
J Cataract Refract Surg ; 50(4): 385-393, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38015426

RESUMO

PURPOSE: To compare actual and formula-predicted postoperative refractive astigmatism using measured posterior corneal power measurements and 4 different empiric posterior corneal astigmatism correction models. SETTING: Tertiary care center. DESIGN: Single-center retrospective consecutive case series. METHODS: Using a dataset of 211 eyes before and after tIOL implantation (Hoya Vivinex), IOLMaster 700 (IOLM) or Casia2 (CASIA) keratometric and front/back surface corneal power measurements were converted to power vector components C0 (0/90 degrees) and C45 (45/135 degrees). Differences between postoperative and Castrop formula predicted refraction at the corneal plane using the labeled parameters of the tIOL and the keratometric or front/back surface corneal powers were recorded as the effect of corneal back surface astigmatism (BSA). RESULTS: Generally, the centroid of the difference shifted toward negative C0 values indicating that BSA adds some against the rule corneal astigmatism (ATR). From IOLM/CASIA keratometry, the average difference in C0 was 0.39/0.32 diopter (D). After correction with the Abulafia-Koch, Goggin, La Hood, and Castrop nomograms, it was -0.18/-0.24 D, 0.27/0.18 D, 0.13/0.08 D, and 0.17/0.10 D. Using corneal front/back surface data from IOLM/CASIA, the difference was 0.18/0.12 D. CONCLUSIONS: The Abulafia-Koch method overcorrected the ATR, while the Goggin, La Hood, and Castrop models slightly undercorrected ATR, and using measurements from the CASIA tomographer seemed to produce slightly less prediction error than IOLM.


Assuntos
Astigmatismo , Doenças da Córnea , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Astigmatismo/cirurgia , Estudos Retrospectivos , Refração Ocular , Córnea , Doenças da Córnea/cirurgia , Topografia da Córnea
12.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1553-1565, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38150030

RESUMO

BACKGROUND: Phakic lenses (PIOLs, the most common and only disclosed type being the implantable collamer lens, ICL) are used in patients with large or excessive ametropia in cases where laser refractive surgery is contraindicated. The purpose of this study was to present a strategy based on anterior segment OCT data for calculating the refraction correction (REF) and the change in lateral magnification (ΔM) with ICL implantation. METHODS: Based on a dataset (N = 3659) containing Casia 2 measurements, we developed a vergence-based calculation scheme to derive the REF and gain or loss in ΔM on implantation of a PIOL having power PIOLP. The calculation concept is based on either a thick or thin lens model for the cornea and the PIOL. In a Monte-Carlo simulation considering, all PIOL steps listed in the US patent 5,913,898, nonlinear regression models for REF and ΔM were defined for each PIOL datapoint. RESULTS: The calculation shows that simplifying the PIOL to a thin lens could cause some inaccuracies in REF (up to ½ dpt) and ΔM for PIOLs with high positive power. The full range of listed ICL powers (- 17 to 17 dpt) could correct REF in a range from - 17 to 12 dpt with a change in ΔM from 17 to - 25%. The linear regression considering anterior segment biometric data and the PIOLP was not capable of properly characterizing REF and ΔM, whereas the nonlinear model with a quadratic term for the PIOLP showed a good performance for both REF and ΔM prediction. CONCLUSION: Where PIOL design data are available, the calculation concept should consider the PIOL as thick lens model. For daily use, a nonlinear regression model can properly predict REF and ΔM for the entire range of PIOL steps if a vergence calculation is unavailable.


Assuntos
Cristalino , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular , Tomografia de Coerência Óptica , Cristalino/cirurgia , Refração Ocular
13.
PLoS One ; 18(12): e0296022, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38150488

RESUMO

PURPOSE: To investigate human corneal epithelial cell and fibroblast migration and growth factor secretion after rose bengal photodynamic therapy (RB-PDT) and the effect of conditioned medium (CM). METHODS: A human corneal epithelial cell line (HCE-T), human corneal fibroblasts (HCF) and keratoconus fibroblasts (KC-HCF) have been used. Twenty-four hours after RB-PDT (0.001% RB concentration, 565 nm wavelength illumination, 0.17 J/cm2 fluence) cell migration rate using scratch assay and growth factor concentrations in the cell culture supernatant using ELISA have been determined. In addition, the effect of CM has been observed. RESULTS: RB-PDT significantly reduced migration rate in all cell types, compared to controls (p≤0.02). Migration rate of HCE-T cultures without RB-PDT (untreated) was significantly higher using HCF CM after RB-PDT, than using HCF CM without RB-PDT (p<0.01). Similarly, untreated HCF displayed a significantly increased migration rate with HCE-T CM after RB-PDT, compared to HCE-T CM without treatment (p<0.01). Furthermore, illumination alone and RB-PDT significantly decreased keratinocyte growth factor (KGF) concentration in HCF and KC-HCF supernatant, and RB-PDT significantly decreased soluble N-Cadherin (SN-Cad) concentration in HCF supernatant, compared to controls (p<0.01 for all). In HCE-T CM, RB-PDT increased hepatocyte growth factor (HGF) and basic fibroblast growth factor (FGFb) concentration (p≤0.02), while decreasing transforming growth factor ß (TGF-ß) concentration (p<0.01). FGFb concentration increased (p<0.0001) and TGF-ß concentration decreased (p<0.0001) in HCF CM, by RB-PDT. Epidermal growth factor (EGF), HGF, and TGF-ß concentration decreased (p≤0.03) and FGFb concentration increased (p<0.01) in KC-HCF CM, using RB-PDT. CONCLUSIONS: HCE-T, HCF and KC-HCF migration rate is reduced 24 hours after RB-PDT. In contrast, HCE-T migration is enhanced using HCF CM after RB-PDT, and HCF migration rate is increased through HCE-T CM following RB-PDT. Modulation of EGF, KGF, HGF, FGFb, TGF-ß and N-Cadherin secretion through RB-PDT may play an important role in corneal wound healing.


Assuntos
Fator de Crescimento Epidérmico , Fotoquimioterapia , Humanos , Fator de Crescimento Epidérmico/farmacologia , Fator de Crescimento Epidérmico/metabolismo , Meios de Cultivo Condicionados/farmacologia , Meios de Cultivo Condicionados/metabolismo , Rosa Bengala/farmacologia , Células Cultivadas , Fibroblastos/metabolismo , Movimento Celular , Fator de Crescimento Transformador beta/metabolismo , Células Epiteliais , Caderinas/metabolismo , Fator 7 de Crescimento de Fibroblastos/metabolismo , Fator 7 de Crescimento de Fibroblastos/farmacologia
14.
PLoS One ; 18(9): e0288316, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37682881

RESUMO

BACKGROUND: Intraocular lenses are typically calculated based on a pseudophakic eye model, and for toric lenses (tIOL) a good estimate of corneal astigmatism after cataract surgery is required in addition to the equivalent corneal power. The purpose of this study was to investigate the differences between the preoperative IOLMaster (IOLM) and the preoperative and postoperative Casia2 (CASIA) tomographic measurements of corneal power in a cataractous population with tIOL implantation, and to predict total power (TP) from the IOLM and CASIA keratometric measurements. METHODS: The analysis was based on a dataset of 88 eyes of 88 patients from 1 clinical centre before and after tIOL implantation. All IOLM and CASIA keratometric and total corneal power measurements were converted to power vector components, and the differences between preoperative IOLM or CASIA and postoperative CASIA measurements were assessed. Feedforward neural network and multivariate linear regression prediction algorithms were implemented to predict the postoperative total corneal power (as a reference for tIOL calculation) from the preoperative IOLM and CASIA keratometric measurements. RESULTS: On average, the preoperative IOLM keratometric / total corneal power under- / overestimates the postoperative CASIA keratometric / real corneal power by 0.12 dpt / 0.21 dpt. The prediction of postoperative CASIA real power from preoperative IOLM or CASIA keratometry shows that postoperative total corneal power is systematically (0.18 dpt / 0.27 dpt) shifted towards astigmatism against the rule, which is not reflected by keratometry. The correlation of postoperative CASIA real power to the corresponding preoperative CASIA values is better than those as compared to the preoperative IOLM keratometry. However, there is a large variation from preoperative IOLM or CASIA keratometry to the postoperative CASIA real power of up to 1.1 dpt (95% confidence interval). CONCLUSION: One of the challenges of tIOL calculation is the prediction of postoperative total corneal power from preoperative keratometry. Keratometric power restricted to a front surface measurement does not fully reflect the situation of corneal back surface astigmatism, which typically adds some extra against the rule astigmatism.


Assuntos
Astigmatismo , Catarata , Doenças da Córnea , Fabaceae , Lentes Intraoculares , Lentes , Humanos , Astigmatismo/diagnóstico , Astigmatismo/cirurgia , Córnea/cirurgia
15.
J Clin Med ; 12(16)2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37629268

RESUMO

BACKGROUND: Monoclonal gammopathy (MG) is characterized by monoclonal protein overproduction, potentially leading to the development of hyperviscosity syndrome. OBJECTIVE: To assess retinal circulation using optical coherence tomography angiography (OCTA) parameters in patients with monoclonal gammopathy. METHODS: OCTA measurements were performed using the Optovue AngioVue system by examining 44 eyes of 27 patients with MG and 62 eyes of 36 control subjects. Superficial and deep retinal capillary vessel density (VD SVP and DVP) in the whole 3 × 3 mm macular and parafoveal area, foveal avascular zone (FAZ) area, and central retinal thickness (CRT) were measured using the AngioAnalytics software. The OCTA parameters were evaluated in both groups using a multivariate regression model, after controlling for the effect of imaging quality (SQ). RESULTS: There was no significant difference in age between the subjects with monoclonal gammopathy and the controls (63.59 ± 9.33 vs. 58.01 ± 11.46 years; p > 0.05). Taking into account the effect of image quality, the VD SVP was significantly lower in the MG group compared to the control group (44.54 ± 3.22% vs. 46.62 ± 2.84%; p < 0.05). No significant differences were found between the two groups regarding the other OCTA parameters (p > 0.05). CONCLUSIONS: A decreased superficial retinal capillary vessel density measured using OCTA in patients with MG suggests a slow blood flow, reduced capillary circulation, and consequent tissue hypoperfusion. An evaluation of retinal circulation using OCTA in cases of monoclonal gammopathy may be a sensitive method for the non-invasive detection and follow-up of early microcirculatory dysfunction caused by increased viscosity.

16.
Br J Ophthalmol ; 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-37495264

RESUMO

PURPOSE: The purpose of this study was to develop a concept for predicting the effects of both discrete intraocular lens (IOL) power steps (PS) and power labelling tolerances (LT) on the uncertainty of the refractive outcome (REFU). DESIGN: Retrospective non-randomised cross-sectional Monte Carlo simulation study. METHODS: We evaluated a dataset containing 16 669 IOLMaster 700 preoperative biometric measurements. The PS and the delivery range of two modern IOLs (Bausch and Lomb enVista and Alcon SA60AT) were considered for this Monte Carlo simulation. The uncertainties from PS or LT were assumed to be normally distributed according to ±½ the IOL PS or the ISO 11979 LT. REFU was recorded and analysed for all simulations. RESULTS: With both lenses the REFU from discrete PS ranged from 0.11 to 0.12 dpt. Due to the larger PS for low/high power lenses with the enVista/SA60AT, REFU is more dominant in initially myopic/hyperopic eyes. REFU from LT ranged from 0.18 to 0.19 dpt for both lenses. Since LT increases stepwise with IOL power, REFU is more prevalent in initially hyperopic eyes requiring high IOL power values, and for lenses with a wide delivery range towards higher powers. CONCLUSIONS: Since surgeons and patients are typically aware of the effect of discrete PS on REFU, these might be tolerated in cataract surgery. However, REFU resulting from LT is inevitable while the true measured IOL power is not reported on the package, leading to background noise in postoperative achieved refraction.

17.
Ocul Immunol Inflamm ; : 1-10, 2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36799910

RESUMO

PURPOSE: To investigate expression of cytokines and ROS-related genes in stromal cells of healthy and keratoconus (KC) corneas. METHODS: Expression analysis was performed for cytokines including several interleukins (IL), Tumor necrosis factor-α (TNF-α), Transforming growth factor-ß1 (TGF-ß1), Interferon-γ (IFN-γ) and ROS-related genes such as Catalase, Glutathione peroxidase 1, NADPH oxidase 1, superoxide dismutase 1 in corneal fibroblasts (HCFs/KC-HCFs) or keratocytes (Keratocytes/KC-Keratocytes) by qPCR and ELISA. RESULTS: Gene and protein expression of most inflammatory markers was decreased in keratocytes compared to fibroblasts, whereas no differences were found between healthy and keratoconus cells for the majority of cytokines measured. TNF-α expression was increased at gene (KC keratocytes) and protein levels (supernatant of Keratocytes/KC-Keratocytes) compared to corneal fibroblasts. No differential expression of ROS-related genes was detected between healthy and diseased cells in both fibroblasts and keratocytes. CONCLUSION: Increased expression of several inflammatory markers described as altered in KC was not evident in KC cells in vitro.

18.
Z Med Phys ; 2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36813595

RESUMO

PURPOSE: To implement a fully data driven strategy for identifying outliers in clinical datasets used for formula constant optimisation, in order to achieve proper formula predicted refraction after cataract surgery, and to assess the capabilities of this outlier detection method. METHODS: 2 clinical datasets (DS1/DS2: N = 888/403) of eyes treated with a monofocal aspherical intraocular lens (Hoya XY1/Johnson&Johnson Vision Z9003) containing preoperative biometric data, power of the lens implant and postoperative spherical equivalent (SEQ) were transferred to us for formula constant optimisation. Original datasets were used to generate baseline formula constants. A random forest quantile regression algorithm was set up using bootstrap resampling with replacement. Quantile regression trees were grown and the 25% and 75% quantile, and the interquartile range were extracted from SEQ and formula predicted refraction REF for the SRKT, Haigis and Castrop formulae. Fences were defined from the quantiles and data points outside the fences were marked and removed as outliers before recalculating the formula constants. RESULTS: NB = 1000 bootstrap samples were derived from both datasets, and random forest quantile regression trees were grown to model SEQ versus REF and to estimate the median and 25% and 75% quantiles. The fence boundaries were defined as being from 25% quantile - 1.5·IQR to 75% quantile + 1.5·IQR, with data points outside the fence being marked as outliers. In total, for DS1 and DS2, 25/27/32 and 4/5/4 data points were identified as outliers for the SRKT/Haigis/Castrop formulae respectively. The respective root mean squared formula prediction errors for the three formulae were slightly reduced from: 0.4370 dpt;0.4449 dpt/0.3625 dpt;0.4056 dpt/and 0.3376 dpt;0.3532 dpt to: 0.4271 dpt;0.4348 dpt/0.3528 dpt;0.3952 dpt/0.3277 dpt;0.3432 dpt for DS1;DS2. CONCLUSION: We were able to prove that with random forest quantile regression trees a fully data driven outlier identification strategy acting in the response space is achievable. In a real life scenario this strategy has to be complemented by an outlier identification method acting in the parameter space for a proper qualification of datasets prior to formula constant optimisation.

19.
Ther Adv Ophthalmol ; 14: 25158414221118524, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36061972

RESUMO

Intraocular lens (IOL) power calculation after corneal refractive surgery (CRS) becomes an expanding challenge for ophthalmologists as more and more cataract surgeries after CRS are required. These patients typically also have high expectations as to visual performance. Conventional IOL power calculation schemes frequently provide inaccurate results in these cases. This review aims to summarize and recommend currently available IOL power calculation methods for eyes with the most common CRS methods: radial keratotomy (RK), photorefractive keratectomy (PRK), laser in situ keratomileusis (LASIK), and small incision lenticule extraction (SMILE). To this end, biometry measuring methods and IOL formulas will be explained and combinations of both are proposed. In synopsis, it is evident that the latest generation of vergence formulas exhibit favorable IOL power prediction accuracy in post-CRS eyes, even though the predictive precision of methods in eyes without CRS is not attained. Ray tracing computation, intraoperative aberrometry, and machine learning-based formulas hold potential to further improve refractive outcomes in post-CRS eyes.

20.
Microorganisms ; 10(8)2022 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-36014060

RESUMO

Acanthamoeba keratitis (AK) is a dangerous infectious disease, which is associated with a high risk of blindness for the infected patient, and for which no standard therapy exists thus far. Patients suffering from AK are thus treated, out of necessity, with an off-label therapy, using drugs designed and indicated for other diseases/purposes. Here, we tested the capability of the off-label anti-amoebic drugs chlorhexidine (CH; 0.1%), dibromopropamidine diisethionate (DD; 0.1%), hexamidine diisethionate (HD; 0.1%), miltefosine (MF; 0.0065%), natamycin (NM; 5%), polyhexamethylene biguanide (PHMB; 0.02%), povidone iodine (PVPI; 1%), and propamidine isethionate (PD; 0.1%) to suppress trophozoite formation of Acantamoeba castellanii and Acanthamoeba hatchetti cysts on non-nutrient agar Escherichia coli plates. Of the eight off-label anti-amoebic drugs tested, only PVPI allowed for a complete suppression of trophozoite formation by drug-challenged cysts for all four Acanthamoeba isolates in all five biological replicates. Drugs such as NM, PD, and PHMB repeatedly suppressed trophozoite formation with some, but not all, tested Acanthamoeba isolates, while other drugs such as CH, DD, and MF failed to exert a relevant effect on the excystation capacities of the tested Acanthamoeba isolates in most, if not all, of our repetitions. Our findings suggest that pre-testing of the AK isolate with the non-nutrient agar E. coli plate assay against the anti-amoebic drug intended for treatment should be performed to confirm that the selected drug is cysticidal for the Acanthamoeba isolate.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA