1.
Pacing Clin Electrophysiol ; 47(4): 496-502, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38462721

RESUMO

BACKGROUND: Inappropriate shock (IAS) caused by subcutaneous air entrapment (AE) in an early period after subcutaneous implantable cardioverter defibrillator (S-ICD) implantation has been reported, however, no detailed data on air volume are available. We evaluated the subcutaneous air volume after implantation and its absorption rate one week after implantation. METHODS: Patients who underwent S-ICD implantation in our hospital received chest CT scans immediately after implantation and followed up 1 week later. The total subcutaneous air volume, air around the generator, the distal electrode, and the proximal electrode within 3 cm were calculated using a three-dimensional workstation. Fat areas at the level of the lower edge of the generator were also analyzed. RESULT: Fifteen patients received CT immediately after implantation. The mean age was 45.6 ± 17.9 (66.7% of men), and the mean body mass index was 24.3 ± 3.3. The three-incision technique was applied in seven patients and two-incision technique was in the latter eight patients. The mean total subcutaneous air volume was 18.54 ± 7.50 mL. Air volume around the generator, the distal electrode, and the proximal electrode were 11.05 ± 5.12, 0.72 ± 0.72, and 0.88 ± 0.87 mL, respectively. Twelve patients received a follow-up CT 1 week later. The mean total subcutaneous air was 0.25 ± 0.45 mL, showing a 98.7% absorption rate. CONCLUSION: Although subcutaneous air was observed in all patients after S-ICD implantation, most of the air was absorbed within 1 week, suggesting a low occurrence of AE-related IAS after a week postoperation.


Assuntos
Desfibriladores Implantáveis , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Tomografia Computadorizada por Raios X , Tomografia , Resultado do Tratamento
2.
Surg Case Rep ; 6(1): 287, 2020 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-33188464

RESUMO

BACKGROUND: Solitary fibrous tumors (SFTs) are rare tumors, mostly derived from connective tissue mesenchymal cells that arise from the pleura. There are very few reports of primary pancreatic SFT. Preoperative diagnosis is difficult owing to the lack of distinctive radiological findings. We report a case of pancreatic SFT with particularly rare malignant findings. CASE PRESENTATION: A 60-year-old man was referred to the hospital because of a right upper quadrant mass and abnormal liver function test results. Contrast-enhanced computed tomography (CT) showed a well-defined enhanced tumor measuring approximately 8 cm in the pancreatic head. Magnetic resonance imaging (MRI) showed T1WI hypointensity, T2WI hyperintensity, and DWI hyperintensity. The main pancreatic duct and common bile duct were dilated owing to obstruction by the tumor. The following tumor markers were mildly elevated: carcinoembryonic antigen (CEA), carbohydrate antigen 19-9 (CA19-9), SPan-1, and DUPAN-2. The histological diagnosis obtained by endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) was negative for pancreatic ductal carcinoma, malignant lymphoma and neuroendocrine tumor, suggesting the possibility of mesenchymal tumor, but the diagnosis was not confirmed. The patient was judged suitable for surgery and underwent subtotal stomach-preserving pancreatoduodenectomy with D2 lymph node dissection. On histopathological examination of the resected specimen, infiltrating spindle-shaped cells had proliferated, containing numerous mitotic figures, with necrotic findings inside the tumor. Immunostaining was positive for cluster of differentiation-34 (CD34), B cell CLL/lymphoma-2 (Bcl-2), and signal transducer and activator of transcription (STAT6). On the basis of these findings, a diagnosis of malignant pancreatic SFT was made. The patient remains free of recurrent disease after 12 months of follow-up without adjuvant therapy and he is being carefully followed up as an outpatient. CONCLUSIONS: We experienced a case of malignant pancreatic head SFT. Immunohistochemical staining of the extracted specimens was useful for diagnosis.

3.
J Cardiol Cases ; 21(6): 205-208, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32547653

RESUMO

A 76-year-old male was admitted to our hospital for progressive bilateral pleural effusion. Because of typical echocardiographic findings such as left ventricular (LV) hypertrophy, thickness of the mitral valve, and a granular sparkling appearance of the LV wall, amyloid cardiomyopathy was suspected. Regardless of up-titration of several diuretic agents, the bilateral pleural effusion did not improve. Because the histological findings of the right ventricular septum (direct-fast-scarlet staining) obtained by biopsy that demonstrated amyloid deposits in perivascular and pericellular lesions, amyloid cardiomyopathy was diagnosed. However, cardiac catheterization revealed normal right and left atrial pressure and normal right and left ventricular end-diastolic pressure. Therefore, hemodynamic deterioration was less likely to be the cause of persistent pleural effusion. Amyloid deposits were also detected in the pleural biopsy specimen, so pleural amyloidosis was diagnosed and may have played an important role in the refractoriness of the pleural effusion. .

4.
Circ J ; 81(6): 794-798, 2017 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-28250283

RESUMO

BACKGROUND: The characteristics and prognosis of implanted pacemaker-identified new-onset atrial fibrillation (AF) in Japanese people has not been well evaluated.Methods and Results:A total of 395 consecutive patients with newly implanted pacemakers were retrospectively analyzed between January 2010 and December 2015 at Yokohama City University Hospital. Patients with a prior history of AF, VVI mode pacemaker, congenital heart disease, severe valvular heart disease, and cardiovascular surgery before pacemaker implantation were excluded. Among the remaining patients, 44 (21.3%) developed new AF during follow-up (mean follow-up, 1,115±651 days; range, 9-2,176 days). Patients with new-onset AF had a significantly higher CHADS2score (2.09±1.27 vs. 1.31±1.08, P<0.001) and CHA2DS2-VASc score (3.00±1.39 vs. 2.26±1.19, P<0.001) compared with those without new-onset AF. On Cox regression analysis only age at implantation was significantly correlated with new-onset AF. Interestingly, the incidence of hospitalization due to heart failure was significantly higher in the new-onset AF than in the without new-onset AF group. CONCLUSIONS: A total of 21.3% of pacemaker-implanted patients with high CHADS2and CHA2DS2-VASc scores developed new-onset AF during a mean follow-up of 3.1 years; and pacemaker-identified AF was associated with an increased risk of worsening heart failure.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Marca-Passo Artificial/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Fibrilação Atrial/terapia , Feminino , Seguimentos , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/terapia , Humanos , Incidência , Japão , Masculino , Pessoa de Meia-Idade , Prognóstico