Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Visc Surg ; 160(5): 323-329, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37005112

RESUMO

STUDY OBJECTIVE: Breaking bad news (BN) is difficult and necessitates targeted training. To be effective, training may call for High Fidelity Simulation (HFS). This prospective study was conducted to objectively assess the impact of HFS as a tool conducive to the development of clinical competence in situations involving the delivery of bad news. METHODS: This feasibility study was conducted from January to May 2021 and included students in medical oncology and digestive surgery. The subjective and objective impacts of HFS were evaluated by means of a self-administered questionnaire and a wristband, Affect-tag, which recorded several indicators: emotional power (EP), emotional density (DE) and cognitive load (CL) in students undergoing training. RESULTS: Forty-six (46) students with a median age of 25 years (21-34 years) were included. While the participants were effectively and emotionally involved in the HFS training, they were not completely overwhelmed by their emotions, a possible occurrence in this type of program. After two training programs, the students presented with lower EP (P<0.001) and higher DE (P=0.005), while their CL remained stable (P=0.751). The information given in the self-administered questionnaires and the evaluations by outside professionals (actor, nurse, psychologist…) highlighted improved skills. CONCLUSION: Taking into account the emotional parameters observed and the questionnaires collected, HFS can be considered as a suitable and effective tool in the breaking of bad news.


Assuntos
Acacia , Treinamento com Simulação de Alta Fidelidade , Humanos , Adulto , Revelação da Verdade , Estudos Prospectivos , Competência Clínica
2.
J Visc Surg ; 159(2): 114-120, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34024738

RESUMO

BACKGROUND: There exists a misalignment between the information given by a surgeon and the information retained by the patient. Inability to assimilate relevant information can be a factor of preoperative anxiety. The aim of this study was to assess patients' information retention according to a Fédération de Chirurgie Viscérale et Digestive (FCVD) questionnaire. MATERIALS: From 29 June 2020 to 2 August 2020, a prospective, comparative multicenter study was conducted among 89 patients who were about to undergo digestive surgery. They were included either in a standard group (management in accordance with the usual French guidelines) or experimental group, which received a second consultation, one week before surgery. The day before being operated, all the patients filled out 3 questionnaires analyzing their percentage of retention according to two scales: the Amsterdam Preoperative Anxiety and information Scale (APAIS) and the visual analogue scale for anxiety (VAS-A). RESULTS: Patient comprehension of the FCVD information was 94% and 63% in the experimental and the control groups, respectively (P<0.001). The standard group was significantly more anxious than the experimental group, with VAS-A rates of 6.2 and 4.6 (P=0.014), respectively. On the other hand, according to the APAIS scale, they were similarly anxious, with scores of 11.3 versus 11.9, respectively (P=0.200). CONCLUSION: A second transmission of exhaustive information shortly before digestive surgery was conducive to improved retention. Enhanced comprehension and memorization reduced preoperative anxiety.


Assuntos
Ansiedade , Compreensão , Ansiedade/etiologia , Ansiedade/prevenção & controle , Humanos , Medição da Dor , Cuidados Pré-Operatórios , Estudos Prospectivos , Inquéritos e Questionários
3.
Eur J Radiol ; 140: 109751, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34000600

RESUMO

PURPOSE: The aim of this work was to compare, in a clinical study, digital mammography and synthetic mammography imaging by evaluating the contrast in microcalcifications of different sizes. METHODS: A retrospective review of microcalcifications from 46 patients was undertaken. A Hologic 3-Dimensions mammography system and a HD Combo protocol was used for simultaneous acquisition of the digital and synthetic images. Microcalcifications were classified in accordance with their size, and patient breast images were classified in accordance with their density as adipose, moderately dense and dense. The contrast of the microcalcifications was measured and the contrast ratio between synthetic and digital images was compared. An additional qualitative assessment of the images was presented to correlate the conspicuity of the microcalcifications with the suppression of the structure noise. RESULTS: Microcalcifications in adipose background always exhibit a comparable or better contrast on synthetic images, regardless their size. For moderately dense background, synthetic images show a better contrast in 91.2 % of cases for small microcalcifications and in 90.9 % of cases for large microcalcifications. For a dense background, better contrast is seen in 89.5 % of cases for small microcalcifications, and in 85.7 % of cases for large microcalcifications. The contrast ratio increases with increasing breast glandularity. The suppression of structure noise also contributes to the enhancement of microcalcifications in the synthetic images. CONCLUSIONS: Synthetic mammography imaging is superior to digital mammography imaging in terms of microcalcification contrast, regardless their size and breast density.


Assuntos
Doenças Mamárias , Neoplasias da Mama , Calcinose , Mama/diagnóstico por imagem , Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Humanos , Mamografia , Intensificação de Imagem Radiográfica , Estudos Retrospectivos
4.
Clin Transl Oncol ; 23(6): 1220-1237, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33677709

RESUMO

PURPOSE: The application of nanosecond pulsed electric fields (nsPEFs) could be an effective therapeutic strategy for peritoneal metastasis (PM) from colorectal cancer (CRC). The aim of this study was to evaluate in vitro the sensitivity of CT-26 CRC cells to nsPEFs in combination with chemotherapeutic agents, and to observe the subsequent in vivo histologic response. METHODS: In vitro cellular assays were performed to assess the effects of exposure to 1, 10, 100, 500 and 1000 10 ns pulses in a cuvette or bi-electrode system at 10 and 200 Hz. nsPEF treatment was applied alone or in combination with oxaliplatin and mitomycin. Cell death was detected by flow cytometry, and permeabilization and intracellular calcium levels by fluorescent confocal microscopy after treatment. A mouse model of PM was used to investigate the effects of in vivo exposure to pulses delivered using a bi-electrode system; morphological changes in mitochondria were assessed by electron microscopy. Fibrosis was measured by multiphoton microscopy, while the histological response (HR; hematoxylin-eosin-safran stain), proliferation (KI67, DAPI), and expression of immunological factors (CD3, CD4, CD8) were evaluated by classic histology. RESULTS: 10 ns PEFs exerted a dose-dependent effect on CT-26 cells in vitro and in vivo, by inducing cell death and altering mitochondrial morphology after plasma membrane permeabilization. In vivo results indicated a specific CD8+ T cell immune response, together with a strong HR according to the Peritoneal Regression Grading Score (PRGS). CONCLUSIONS: The effects of nsPEFs on CT-26 were confirmed in a mouse model of CRC with PM.


Assuntos
Antibióticos Antineoplásicos/uso terapêutico , Morte Celular , Terapia por Estimulação Elétrica/métodos , Mitomicina/uso terapêutico , Oxaliplatina/uso terapêutico , Neoplasias Peritoneais/patologia , Neoplasias Peritoneais/terapia , Linfócitos T Citotóxicos , Animais , Neoplasias Colorretais/patologia , Terapia Combinada , Modelos Animais de Doenças , Imunocompetência , Camundongos , Neoplasias Peritoneais/secundário , Fatores de Tempo , Resultado do Tratamento
7.
Scand J Surg ; 109(1): 42-52, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31975647

RESUMO

BACKGROUND AND AIMS: Pancreatic neuroendocrine tumors (PNET) arise from uncontrolled proliferation of neuroendocrine cell and further genetic alterations that may induce hormone secretion such as glucagon/insulin/gastrin/VIP. Their incidence is rapidelly growing, especially because of the frequent incidental diagnosis of small asymptomatic non-functionnal neuroendocrine tumors with the widespread use of cross-sectional imaging. The vast majority of pancreatic neuroendocrine tumors are sporadic but up to 5%-10% of them arise from genetic syndromes, the main one being Multiple Endocrine Neopalsm type 1 (MEN1). Appropriate management of patients with PNET is a complex challenge for surgeons, and require extensive medical collaboration. This review aims to summarize major and recent updates regarding the medico-surgical management of PNETs. MATERIAL AND METHODS: Review of pertinent English language literature. RESULTS: This article provides a concise summary of the clinical presentation, diagnosis, surgical management, alternative treatments and follow up of PNETs. CONCLUSION: PNET are a rare, heterogeneous group of neoplasms with a generally favorable prognosis at least compared to pancreatic adenocarcinoma. Surgical resection is the cornerstone of their management, particularly for localized disease, and should always be discussed in multidisciplinary tumor board.


Assuntos
Tumores Neuroendócrinos/cirurgia , Neoplasias Pancreáticas/cirurgia , Assistência ao Convalescente , Humanos , Tumores Neuroendócrinos/diagnóstico , Tumores Neuroendócrinos/terapia , Pancreatectomia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/terapia , Prognóstico
8.
Phys Med Biol ; 64(18): 185002, 2019 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-31307026

RESUMO

Coronary angiography is clinically used worldwide to diagnose diseases of coronary arteries. Despite its effectiveness, this technique is quite invasive and it is associated with significant risks due to the arterial catheterisation needed to inject the contrast agent. A valid alternative is using the K-edge subtraction (KES) method, which is based on the subtraction of two images acquired at energies bracketing the K-edge of the contrast element. The enhanced sensitivity of KES allows the intravenous injection of the contrast agent, thus reducing the risks of catheterisation. This technique can be effectively implemented by using intense and quasi-monochromatic x-ray beams. Synchrotron radiation has been proven to work well for this purpose, but its cost and size prevent a widespread clinical application. Inverse Compton sources are among the most promising innovative sources of intense and quasi-monochromatic x-rays. These sources are intrinsically more compact than those based on synchrotron radiation. In this work, the potential application of inverse Compton radiation to KES angiography is investigated. To this purpose, after a short review of the physics behind the inverse Compton process, an analytical framework is described. The proposed model is based on the application of the KES algorithm to calculate the SNR of details inside a suitable mathematical phantom. That allowed us to identify the characteristics of an inverse Compton source required for KES imaging. In particular, it was estimated that a photon fluence of 108 ph mm-2 is necessary to detect signals of clinical interest. Novel sources based on inverse Compton promise to achieve this requirement with an acquisition time of few hundreds of ms. This feature, together with compactness, broad two-dimensional radiation field, absence of harmonic contamination and the ability to deliver high photon fluxes also at high energies, makes this kind of sources promising for KES angiography and other diagnostic applications.


Assuntos
Angiografia Coronária/métodos , Técnica de Subtração , Algoritmos , Angiografia Coronária/instrumentação , Imagens de Fantasmas , Fótons , Razão Sinal-Ruído , Técnica de Subtração/instrumentação , Síncrotrons , Raios X
9.
Med Phys ; 36(10): 4683-701, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19928100

RESUMO

PURPOSE: A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x rays emitted from thin targets, irradiated by electron beams circulating in the storage ring, is of primary interest for the design and the characterization of a beamline. This article, Part I, aims at optimizing some of the parameters which are critical for the design of medical applications based on the above compact light source. The goal was to evaluate the dependence of photon fluence and beam monochromaticity on electron-beam energy, target material, and thickness. METHODS: The transport of 6 and 20 MeV electrons in a thin molybdenum, rhodium, and tungsten target is studied by means of Monte Carlo simulations using MCNPX. Configurations of the x-ray output port, different from the default forward-directed emission of the beam, are also investigated. A comparison with reference spectra for general diagnostic radiology and mammography is carried out. RESULTS: It is shown that the emitted x-ray beams can be far more intense than those generated by conventional x-ray tubes for radiography applications. The profiles of the calculated polychromatic spectra resemble those generated by conventional x-ray tubes, with x-ray energies up to the energy of the incident-electron beam. An appreciable improvement in the monochromaticity of the beams can be obtained by viewing the x-ray emission from an output port antiparallel to the direction of the incident-electron beam. CONCLUSIONS: The optimum target thickness for tungsten target spectra is practically constrained by a trade-off between bremsstrahlung efficiency and focal-spot size requirements. A larger margin for optimization of target thickness is probably available for mammographic spectra. The constraint of a backward-directed (or, to a lesser extent, orthogonal) output port is to be considered mandatory for minimizing the high-energy tail of the spectral distribution and keeping the radiation dose to a reasonable level. It is also fundamental to evaluate the impact of the high-energy tail of the emitted spectra in x-ray imaging applications, since the energy range involved is significantly beyond the diagnostic range. This topic will be dealt with in Part II of the article.


Assuntos
Desenho Assistido por Computador , Aceleradores de Partículas/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Radiografia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Controle de Qualidade , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Raios X
10.
Phys Med Biol ; 51(17): 4311-28, 2006 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-16912383

RESUMO

The aim of the present work is to analytically evaluate the signal to noise ratio (SNR) and the delivered dose in K-edge digital subtraction imaging (KES) using two types of x-ray sources: a monochromatic x-ray source (available at synchrotron radiation facilities and considered as gold standard) and a quasi-monochromatic compact source. The energy separation DeltaE between the two monochromatic beams is 1 keV and 4 keV for the two sources, respectively. The evaluation has been performed for both radiography and computed tomography. Different geometries have been studied to mimic clinical situations. In mammography, a pathology perfused by a contrast agent has been modelled; in angiography, a vessel superimposed to a ventricle or a stand-alone artery stenosis has been studied. The SNR and the skin dose have been calculated as a function of the detail diameter, the contrast agent (iodine and gadolinium), and its concentration in the tissues. Results show that for DeltaE = 4 keV a slightly higher delivered dose is required to obtain the same SNR with respect to DeltaE < 1 keV. A similar study has been performed for KES-CT. Computer simulations of CT images performed with Snark software are shown to validate the analytical calculations.


Assuntos
Angiografia Digital/métodos , Meios de Contraste/química , Processamento de Sinais Assistido por Computador/instrumentação , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Gadolínio/química , Humanos , Iodo/química , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Phys Med Biol ; 51(17): 4233-51, 2006 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-16912379

RESUMO

Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, that can remove the structural noise, and contrast media, that enhance the region surrounding the tumour, could help us to improve the detectability of the lesions. The aim of this work is to investigate the use of an iodine-based contrast medium in mammography with two different double exposure techniques: K-edge subtraction mammography and temporal subtraction mammography. Both techniques have been investigated by using an ideal source, like monochromatic beams produced at a synchrotron radiation facility and a clinical digital mammography system. A dedicated three-component phantom containing cavities filled with different iodine concentrations has been developed and used for measurements. For each technique, information about the minimum iodine concentration, which provides a significant enhancement of the detectability of the pathology by minimizing the risk due to high dose and high concentration of contrast medium, has been obtained. In particular, for cavities of 5 and 8 mm in diameter filled with iodine solutions, the minimum concentration needed to obtain a contrast-to-noise ratio of 5 with a mean glandular dose of 2 mGy has been calculated. The minimum concentrations estimated with monochromatic beams and K-edge subtraction mammography are 0.9 mg ml(-1) and 1.34 mg ml(-1) for the biggest and smallest details, respectively, while for temporal subtraction mammography they are 0.84 mg ml(-1) and 1.31 mg ml(-1). With the conventional clinical system the minimum concentrations for the K-edge subtraction mammography are 4.13 mg ml(-1) (8 mm diameter) and 5.75 mg ml(-1) (5 mm diameter), while for the temporal subtraction mammography they are 1.01 mg ml(-1) (8 mm diameter) and 1.57 mg ml(-1) (5 mm diameter).


Assuntos
Algoritmos , Meios de Contraste/química , Iodo/química , Técnica de Subtração , Relação Dose-Resposta a Droga , Humanos , Mamografia/instrumentação , Mamografia/métodos , Imagens de Fantasmas , Controle de Qualidade , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos
12.
Phys Med Biol ; 50(10): 2225-40, 2005 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-15876663

RESUMO

Improvement in image contrast and dose reduction, in mammographic x-ray imaging, can be achieved using narrow energy band x-ray beams in the 16-24 keV range. As part of an Italian Government funded project, a quasi-monochromatic system for mammography applications has been developed. The system is based on a tunable narrow energy band x-ray source operating in the 16-24 keV energy range. The bremsstrahlung beam is monochromatized via Bragg diffraction by a highly oriented pyrolytic graphite mosaic crystal (HOPG). The scanning system provides a large field (18 x 24 cm2) of quasi-monochromatic x-rays with energy resolution ranging from 10% at 18 keV to 17.2% at 24 keV. The system has been characterized in terms of fluence rate and energy resolution. An x-ray tube developed ad hoc allows us to acquire images in a reasonable time to minimize the motion blur. A qualitative analysis has been performed in order to know if the prototype system performances are far from a clinical application, by evaluating the spatial resolution, the field uniformity and the image quality as a function of the quasi-monochromatic beam energy. Dose evaluation has been performed as a function of the energy and compared to a conventional system for mammography. The quasi-monochromatic prototype system can produce comparable image quality at half the dose.


Assuntos
Mamografia/instrumentação , Proteção Radiológica/métodos , Radiometria , Medição de Risco/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Imagens de Fantasmas , Projetos Piloto , Doses de Radiação , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
13.
Med Phys ; 32(12): 3755-66, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16475775

RESUMO

Dual-energy mammographic imaging experimental tests have been performed using a compact dichromatic imaging system based on a conventional x-ray tube, a mosaic crystal, and a 384-strip silicon detector equipped with full-custom electronics with single photon counting capability. For simulating mammal tissue, a three-component phantom, made of Plexiglass, polyethylene, and water, has been used. Images have been collected with three different pairs of x-ray energies: 16-32 keV, 18-36 keV, and 20-40 keV. A Monte Carlo simulation of the experiment has also been carried out using the MCNP-4C transport code. The Alvarez-Macovski algorithm has been applied both to experimental and simulated data to remove the contrast between two of the phantom materials so as to enhance the visibility of the third one.


Assuntos
Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Silício , Algoritmos , Fenômenos Biofísicos , Biofísica , Feminino , Humanos , Mamografia/estatística & dados numéricos , Método de Monte Carlo , Imagens de Fantasmas/estatística & dados numéricos
14.
Phys Med Biol ; 49(17): 4135-46, 2004 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-15470928

RESUMO

Several techniques have been introduced in the last year to reduce the dose to the patient by minimizing the risk of tumour induced by radiation. In this work the radiological potential of dose reduction in quasi-monochromatic spectra produced via mosaic crystal Bragg diffraction has been evaluated, and a comparison with conventional spectra has been performed for four standard examinations: head, chest, abdomen and lumbar sacral spine. We have simulated quasi-monochromatic x-rays with the Shadow code, and conventional spectra with the Spectrum Processor. By means of the PCXMC software, we have simulated four examinations according to parameters established by the European Guidelines, and calculated absorbed dose for principal organs and the effective dose. Simulations of quasi-monochromatic laminar beams have been performed without anti-scatter grid, because of their inherent scatter geometry, and compared with simulations with conventional beams with anti-scatter grids. Results have shown that the dose reduction due to the introduction of quasi-monochromatic x-rays depends on different parameters related to the quality of the beam, the organ composition and the anti-scatter grid. With parameters chosen in this study a significant dose reduction can be achieved for two out of four kinds of examination.


Assuntos
Cabeça/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Radiografia Abdominal/métodos , Radiografia Torácica/métodos , Radiologia/métodos , Algoritmos , Humanos , Imagens de Fantasmas , Fótons , Doses de Radiação , Radiometria , Espalhamento de Radiação , Software , Espectrofotometria , Tecnologia Radiológica , Raios X
15.
Phys Med Biol ; 48(13): 1945-56, 2003 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-12884927

RESUMO

A dual-energy technique which employs the basis decomposition method is being investigated for application to digital mammography. A three-component phantom, made up of plexiglas, polyethylene, and water, was doubly exposed with the full-field digital mammography system manufactured by General Electric. The 'low' and 'high' energy images were recorded with a Mo/Mo anode-filter combination and a Rh/Rh combination, respectively. The total dose was kept within the acceptable levels of conventional mammography. The first hybrid images obtained with the dual-energy algorithm are presented in comparison with a conventional radiograph of the phantom. Image-quality characteristics at contrast cancellation angles between plexiglas and water are discussed. Preliminary results show that a combination of a standard Mo-anode 28 kV radiograph with a Rh-anode 49 kV radiograph provides the best compromise between image-quality and dose in the hybrid image.


Assuntos
Diagnóstico por Imagem/métodos , Mamografia/instrumentação , Mamografia/métodos , Algoritmos , Calibragem , Meios de Contraste/farmacologia , Modelos Estatísticos , Imagens de Fantasmas , Raios X
16.
Phys Med Biol ; 47(22): 4093-105, 2002 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-12476984

RESUMO

Dual-energy radiography is an effective technique that allows removal of contrast between pairs of materials in order to display details of interest on a uniform background. In mammographic images the detection of small nodules is often impeded by obscuring background 'clutter' resulting from the contrast between normal tissues (glandular and adipose) in their neighbourhood. We consider whether it could be possible to apply dual-energy radiography to the breast, which is hypothetically principally composed of three tissues, glandular, adipose and cancerous, in order to remove the contrast due to the distribution of normal tissues and, as a consequence, to enhance the intrinsic contrast of the pathology. The purpose of this work is to test the limitations of dual-energy radiography on a three-component phantom under optimum conditions of the source and detector. We use a synchrotron monochromatic beam, produced at the ELETTRA synchrotron facility (Trieste, Italy), and an imaging plate detector, in order to acquire two images at low and high energies of a phantom composed of polyethylene, plexiglas and water. For evaluation of the potential of this procedure we studied the signal-to-noise ratio (SNR) of polyethylene and water on a set of images obtained by applying the dual-energy procedure. We found that the SNR of polyethylene and water is around the detectability threshold (according to Rose's criteria) at the contrast cancellation angles. Finally we evaluated the air entrance dose required for this double exposure, resulting in 0.81 mGy for the low-energy image and 0.01 mGy for the high-energy image. To obtain the same image quality for a standard breast of 5.5 cm, mean glandular doses of 3.50 mGy and 0.03 mGy at 17 keV and at 34 keV, respectively, are required.


Assuntos
Algoritmos , Análise de Falha de Equipamento/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Síncrotrons , Análise de Falha de Equipamento/instrumentação , Estudos de Viabilidade , Mamografia/instrumentação , Mamografia/métodos , Imagens de Fantasmas , Controle de Qualidade , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Sensibilidade e Especificidade , Processos Estocásticos
17.
Phys Med Biol ; 47(2): 305-13, 2002 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-11837619

RESUMO

Dual-energy radiography has not evolved into a routine clinical examination yet due to intrinsic limitations of both dual-kVp imaging and single-exposure imaging with conventional x-ray sources. The recent introduction of novel quasi-monochromatic x-ray sources and detectors could lead to interesting improvements, especially in mammography where the complex structure of healthy tissues often masks the detectability of lesions. A dual-energy radiography technique based on a tissue cancellation algorithm has been developed for mammography, with the aim of maximizing the low intrinsic contrast of pathologic tissues while being able to minimize or cancel the contrast between glandular and fat tissues. Several images of a plastic test object containing various tissue equivalent inserts were acquired in the energy range 17-36 keV using a quasi-monochromatic x-ray source and a scintillator-coated CCD detector. Images acquired at high and low energies were nonlinearly combined to generate two energy-independent basis images. Suitable linear combinations of these two basis images result in the elimination of the contrast of a given material with respect to another. This makes it possible to selectively cancel certain details in the processed image.


Assuntos
Mamografia/instrumentação , Mamografia/métodos , Raios X , Algoritmos , Feminino , Humanos , Imagens de Fantasmas
18.
Med Phys ; 28(4): 412-8, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11339737

RESUMO

A novel x-ray source for mammography application is being investigated. Quasimonochromatic x rays have been produced via Bragg diffraction with a W-anode x-ray tube and a graphite mosaic crystal array. The system provides 18 keV x rays with an energy resolution deltaE/E approximately equals 0.12. A thorough analysis of the spatial resolution of the system has been performed in order to understand and quantify the effect of the introduction of an active optical element such as a mosaic crystal in the x-ray path. The focal spot of the source and its emission properties have been studied by using the slit camera method. Experiments have shown that the introduction of a mosaic crystal in the optical path modifies the resolution properties of the Bragg diffraction-based radiography system. Along the direction perpendicular to the diffraction plane the resolution properties of the imaging system mainly depend on the x-ray tube focal spot size and position. Along the diffraction plane the focal spot size depends on mosaic characteristics and on the geometrical setup. Hence, it could be modified by setting the appropriate experimental conditions.


Assuntos
Mamografia/instrumentação , Raios X , Modelos Teóricos
20.
Phys Med Biol ; 41(12): 2799-806, 1996 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8971970

RESUMO

A novel digital x-ray detector has been assembled. The imaging system is based on a phosphor-coated charge-coupled device (CCD) obtained by direct deposition of a gadolinium oxysulphide scintillator onto the detector surface. The modulation transfer function has been measured along the two directions of the digital coordinates with the narrow slit technique. A resolution limit of about 20 line pairs per mm has been obtained for both directions. The high spatial resolution currently demanded in mammography can be achieved with this imaging system.


Assuntos
Câmaras gama , Mamografia/instrumentação , Radiografia/instrumentação , Desenho de Equipamento , Feminino , Humanos , Mamografia/métodos , Radiografia/métodos , Contagem de Cintilação , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA