Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
J Magn Reson Imaging ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38490816

RESUMO

BACKGROUND: Portal vein thrombosis (PVT) is thought to arise from stagnant blood flow, yet conclusive evidence is lacking. Relative residence time (RRT) assessed using 4D Flow MRI may offer insight into portal flow stagnation. PURPOSE: To explore the relationship between RRT values and the presence of PVT in cirrhotic participants. STUDY TYPE: Prospective. POPULATION: Forty-eight participants with liver cirrhosis (27 males, median age 67 years [IQR: 57-73]) and 20 healthy control participants (12 males, median age 45 years [IQR: 40-54]). FIELD STRENGTH/SEQUENCE: 3 T/4D Flow MRI. ASSESSMENT: Laboratory (liver and kidney function test results and platelet count) and clinical data (presence of tumors and other imaging findings), and portal hemodynamics derived from 4D Flow MRI (spatiotemporally averaged RRT [RRT-mean], flow velocity, and flow rate) were analyzed. STATISTICAL TESTS: We used multivariable logistic regression, adjusted by selected covariates through the Lasso method, to explore whether RRT-mean is an independent risk factor for PVT. The area under the ROC curve (AUC) was also calculated to assess the model's discriminative ability. P < 0.05 indicated statistical significance. RESULTS: The liver cirrhosis group consisted of 16 participants with PVT and 32 without PVT. Higher RRT-mean values (odds ratio [OR] 11.4 [95% CI: 2.19, 118]) and lower platelet count (OR 0.98 per 1000 µL [95% CI: 0.96, 0.99]) were independent risk factors for PVT. The incorporation of RRT-mean (AUC, 0.77) alongside platelet count (AUC, 0.75) resulted in an AUC of 0.84. When including healthy control participants, RRT-mean had an adjusted OR of 12.4 and the AUC of the combined model (RRT-mean and platelet count) was 0.90. DATA CONCLUSION: Prolonged RRT values and low platelet count were significantly associated with the presence of PVT in cirrhotic participants. RRT values derived from 4D Flow MRI may have potential clinical relevance in the management of PVT. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.

2.
Radiology ; 308(3): e230709, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37750777

RESUMO

Background Percutaneous transhepatic portal vein (PV) embolization (PVE) is a standard preoperative procedure for advanced biliary cancer when the future liver remnant (FLR) is insufficient, yet the effect of this procedure on portal hemodynamics is still unclear. Purpose To assess whether four-dimensional (4D) MRI flowmetry can be used to estimate FLR volume and to identify the optimal time for this measurement. Materials and Methods This prospective single-center study enrolled consecutive adult patients with biliary cancer who underwent percutaneous transhepatic PVE for the right liver between June 2020 and November 2022. Portal hemodynamics were assessed using 4D flow MRI before PVE and within 1 day (0-day group) or 3-4 days (3-day group) after PVE. FLR volume was measured using CT before PVE and after PVE but before surgery. Blood flow changes were analyzed with the Wilcoxon signed rank test, and correlations with Spearman rank correlation. Results The 0-day group included 24 participants (median age, 72 years [IQR, 69-77 years]; 17 male participants), and the 3-day group included 13 participants (median age, 71 years [IQR, 68-78 years]; eight male participants). Both groups showed increased left PV (LPV) flow rate after PVE (0-day group: from median 3.72 mL/sec [IQR, 2.83-4.55 mL/sec] to 9.48 mL/sec [IQR, 8.12-10.7 mL/sec], P < .001; 3-day group: from median 3.65 mL/sec [IQR, 2.14-3.79 mL/sec] to 8.16 mL/sec [IQR, 6.82-8.98 mL/sec], P < .001). LPV flow change correlated with FLR volume change relative to the number of days from PVE to presurgery CT only in the 3-day group (ρ = 0.62, P = .02; 0-day group, P = .11). The output of the regression equation for estimating presurgery FLR volume correlated with CT-measured volume (ρ = 0.78; P = .002). Conclusion Four-dimensional flow MRI demonstrated increased blood flow in residual portal branches 3-4 days after PVE, offering insights for estimating presurgery FLR volume. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Roldán-Alzate and Oechtering in this issue.


Assuntos
Neoplasias do Sistema Biliar , Embolização Terapêutica , Neoplasias Hepáticas , Adulto , Humanos , Masculino , Idoso , Veia Porta/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Fígado/diagnóstico por imagem , Embolização Terapêutica/métodos , Imageamento por Ressonância Magnética , Hemodinâmica , Hepatectomia/métodos , Resultado do Tratamento
3.
Eur J Vasc Endovasc Surg ; 66(1): 17-26, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36736616

RESUMO

OBJECTIVE: To predict sac enlargement with type II endoleak (ELII) before endovascular aneurysm repair (EVAR) using four dimensional flow sensitive magnetic resonance imaging (4D flow MRI). METHODS: A single centre retrospective analysis of prospectively collected data was conducted. Patients with an abdominal aortic aneurysm (AAA) who underwent EVAR between 2013 and 2019 were included. Aortic branches occluded pre-EVAR, and patients with endoleaks other than ELII were excluded. The aortic branch diameter, peak flow velocity (PFVe), and amplitude of the dynamics of flow volume (AFV) were measured in each aortic branch pre-EVAR. Total flow volume per minute (TFV/min), defined as the sum of AFV/min, was calculated in each case. According to computed tomography findings one year post-EVAR, the aortic branches and patients were divided into patent vessel and occluded vessel groups and sac expanding and non-expanding groups. PFVe, AFV/min, and TFV/min were analysed via receiver operating characteristic curve analysis. RESULTS: The patent aortic branches pre-EVAR (69 inferior mesenteric arteries [IMAs]; 249 lumbar arteries [LAs]) of 100 patients were included. Patent IMAs (n = 14) and occluded IMAs (n = 55), patent LAs (n = 23) and occluded LAs (n = 226), and expanding (n = 9) and non-expanding (n = 91) groups were compared, respectively. No statistically significant difference was observed in branch diameters (IMA; patent, 2.5 ± 0.8 mm, occluded, 2.5 ± 0.8 mm, p < .78 and LA; patent, 1.5 ± 0.3 mm, occluded, 1.5 ± 0.4 mm, p < .35). PFVe (IMA; patent, 262.6 mm2/sec, occluded, 183.4 mm2/sec and LA; patent, 142.6 mm2/sec, occluded, 47.7 mm2/sec) and AFV/min (IMA; patent, 8.4 mL, occluded, 5.2 mL and LA; patent, 4.2 mL, occluded, 1.4 mL) were higher in the patent vessel group (p < .050). TFV/min was statistically significantly higher in the expanding group (24.1 mL/min) than in the non-expanding group (7.0 mL/min) (p < .010). CONCLUSION: Pre-EVAR haemodynamic analyses using 4D flow MRI were useful to detect aortic branches responsible for ELII and to predict AAA cases with sac enlargement. This analysis suggests a new strategy for pre-EVAR aortic branch embolisation.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/patologia , Estudos Retrospectivos , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Aorta Abdominal/patologia , Fatores de Risco , Imageamento por Ressonância Magnética , Resultado do Tratamento
4.
Magn Reson Med Sci ; 22(3): 273-281, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34615837

RESUMO

PURPOSE: To elucidate MRI features of primary hepatic mucosa-associated lymphoid tissue (MALT) lymphoma, particularly, the "speckled enhancement" on gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI. METHODS: The institutional review board approved this retrospective observational study and waived informed consent. Using our picture archiving and communication systems and electronic medical records, five patients histopathologically diagnosed as hepatic MALT lymphoma and clinically confirmed as primary lesions who had undergone dynamic contrast-enhanced (DCE)-CT and DCE-MRI with Gd-EOB-DTPA were identified from September 2009 to December 2020. Two radiologists assessed their CT and MRI data in consensus with a pathologist's advice. RESULTS: Overall, five lesions in five patients were included in this study. Precontrast CT showed hypoattenuation in all lesions. In the arterial phase of DCE-CT, four lesions (80%) showed hyperattenuation, whereas all lesions showed iso- to hypoattenuation in the delayed phase. A vessel penetration sign was also observed in all lesions. On MRI, all lesions showed hypointensity on T1-weighted images, hyperintensity on T2-weighted images, and restricted diffusion on diffusion-weighted images. Both DCE-CT and DCE-MRI with Gd-EOB-DTPA showed similar enhancement patterns, except for the hepatocyte phase. Notably, however, four out of five lesions showed characteristic "speckled enhancement" that refers to punctate positive enhancements within the low signal lesions on the hepatobiliary phase of Gd-EOB-DTPA-enhanced MRI pathologically confirmed to be hepatocyte clusters that remained in the tumor. CONCLUSION: Primary hepatic MALT lymphomas were characterized by arterial phase enhancement, restricted diffusion, vessel penetration sign, and more specifically "speckled enhancement" in the hepatobiliary phase of DCE-MRI with Gd-EOB-DTPA.


Assuntos
Neoplasias Hepáticas , Linfoma de Zona Marginal Tipo Células B , Humanos , Linfoma de Zona Marginal Tipo Células B/diagnóstico por imagem , Meios de Contraste , Gadolínio DTPA , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia
5.
Magn Reson Med Sci ; 21(2): 380-399, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35173116

RESUMO

Blood flow imaging becomes an emerging trend in cardiology with the recent progress in computer technology. It not only visualizes colorful flow velocity streamlines but also quantifies the mechanical stress on cardiovascular structures; thus, it can provide the detailed inspections of the pathophysiology of diseases and predict the prognosis of cardiovascular functions. Clinical applications include the comprehensive assessment of hemodynamics and cardiac functions in echocardiography vector flow mapping (VFM), 4D flow MRI, and surgical planning as a simulation medicine in computational fluid dynamics (CFD).For evaluation of the hemodynamics, novel mathematically derived parameters obtained using measured velocity distributions are essential. Among them, the traditional and typical parameters are wall shear stress (WSS) and its related parameters. These parameters indicate the mechanical damages to endothelial cells, resulting in degenerative intimal change in vascular diseases. Apart from WSS, there are abundant parameters that describe the strength of the vortical and/or helical flow patterns. For instance, vorticity, enstrophy, and circulation indicate the rotating flow strength or power of 2D vortical flows. In addition, helicity, which is defined as the cross-linking number of the vortex filaments, indicates the 3D helical flow strength and adequately describes the turbulent flow in the aortic root in cases with complicated anatomies. For the description of turbulence caused by the diseased flow, there exist two types of parameters based on completely different concepts, namely: energy loss (EL) and turbulent kinetic energy (TKE). EL is the dissipated energy with blood viscosity and evaluates the cardiac workload related to the prognosis of heart failure. TKE describes the fluctuation in kinetic energy during turbulence, which describes the severity of the diseases that cause jet flow. These parameters are based on intuitive and clear physiological concepts, and are suitable for in vivo flow measurements using inner velocity profiles.


Assuntos
Células Endoteliais , Hemodinâmica , Aorta , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento por Ressonância Magnética/métodos , Estresse Mecânico
6.
Nagoya J Med Sci ; 83(4): 869-875, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34916729

RESUMO

A 59-year-old man with jaundice and lower common bile duct stenosis was referred to our institution for diagnosis and treatment. Computed tomography and magnetic resonance imaging showed a well-circumscribed smoothly marginated solid mass lesion in the pancreatic head. He underwent pyloric preserving pancreatoduodenectomy. Histopathological specimen revealed that the mass was located in the dilated branch duct of the pancreatic head, and an intraductal tubulopapillary neoplasm originating from the branch pancreatic duct was diagnosed. On magnetic resonance cholangiopancreatography, the mass within the dilated duct branch in the pancreatic head was similar to a "cast in the mold" image, which we retrospectively deemed, might be reflecting the nature of this tumor.


Assuntos
Icterícia/etiologia , Pâncreas/diagnóstico por imagem , Neoplasias Intraductais Pancreáticas/diagnóstico , Neoplasias Pancreáticas/diagnóstico , Colangiopancreatografia por Ressonância Magnética/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/patologia , Ductos Pancreáticos/diagnóstico por imagem , Ductos Pancreáticos/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos
7.
J Med Ultrason (2001) ; 48(4): 565-571, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34698963

RESUMO

Autoimmune pancreatitis (AIP) is a pancreatic phenotype of IgG4-related systemic disease. Since its first description in the literature, characteristic imaging features have gradually become known to many clinicians encompassing various specialties in the past quarter century. CT and MRI have been the workhorses for imaging diagnosis of AIP. Typical features include sausage-like swelling of the focal or entire pancreas, duct-penetrating sign, a capsule-like rim of the affected lesions, and homogeneous delayed enhancement or enhanced duct sign after contrast administration, as well as characteristic combined findings reflecting coexisting pathologies in the other organs as a systemic disease. In this review, recent and future developments in CT and MRI that may help diagnose AIP are discussed, including restricted diffusion and perfusion and increased elasticity measured using MR.


Assuntos
Doenças Autoimunes , Pancreatite Autoimune , Neoplasias Pancreáticas , Pancreatite , Doenças Autoimunes/diagnóstico por imagem , Diagnóstico Diferencial , Humanos , Imageamento por Ressonância Magnética , Neoplasias Pancreáticas/diagnóstico , Pancreatite/diagnóstico por imagem , Tomografia Computadorizada por Raios X
8.
Lung Cancer ; 143: 47-54, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32203770

RESUMO

OBJECTIVES: Conventional evaluation of anti-tumor activity on the basis of tumor size is inadequate for immune checkpoint inhibitors (ICIs). We therefore aimed to assess the usefulness of intravoxel incoherent motion magnetic resonance imaging (IVIM-MRI) for evaluation of the therapeutic efficacy of ICIs. MATERIALS AND METHODS: A chest IVIM-MRI was performed before and 2, 4, and 8 weeks after administration of ICIs in patients with advanced non-small-cell lung cancer. Apparent diffusion coefficient (ADC), skewness of ADC (ADCskew), kurtosis of ADC (ADCkurt), true diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f) were evaluated at each evaluation point and changes from the baseline (Δ). RESULTS: Twenty patients were enrolled in this study. An increased ADC 8 weeks and decreased ADCkurt and ΔADCkurt 4 weeks after ICIs was associated with objective responses and longer progression-free survival (PFS). A decreased ΔADCskew at 4 weeks was associated with objective responses, disease control, and longer PFS and overall survival. There was no correlation between the efficacy of ICIs and D, D* and f. All of three patients who had pseudoprogression had decreased ΔADCskew at 4 weeks and two of them had decreased ΔADCkurt at 4 weeks. Inversely, all five patients who had progressive disease (PD) did not have increased ΔADCskew at 4 weeks and only one of them had decreased ΔADCkurt at 4 weeks. CONCLUSIONS: Changes in histograms of ADC may be useful for predicting long-term efficacy and distinguishing between pseudoprogression and actual PD after ICIs.


Assuntos
Adenocarcinoma de Pulmão/patologia , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma de Células Escamosas/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Inibidores de Checkpoint Imunológico/uso terapêutico , Neoplasias Pulmonares/patologia , Adenocarcinoma de Pulmão/tratamento farmacológico , Adenocarcinoma de Pulmão/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/imunologia , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/imunologia , Feminino , Seguimentos , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/imunologia , Masculino , Pessoa de Meia-Idade , Movimento , Prognóstico , Estudos Prospectivos , Taxa de Sobrevida
9.
J Vasc Surg ; 70(1): 107-116.e1, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30792053

RESUMO

OBJECTIVE: The objective of this study was to investigate the hemodynamic parameters of type II endoleaks (T2ELs) to predict sac expansion using four-dimensional flow-sensitive magnetic resonance imaging (4D-flow MRI) analysis. METHODS: Patients who underwent endovascular aneurysm repair (EVAR) and were diagnosed with a T2EL were included in the study. Using 4D-flow MRI at 7 days, the peak flow velocity and amplitude of dynamics of blood flow per minute were measured in each T2EL vessel. The peak flow velocity was defined as the maximum of the absolute value of the blood flow velocity. The amplitude of dynamics of blood flow in the tributary arteries was defined as the sum of the absolute values of the inflow and outflow volume in each vessel. The amplitude of dynamics of blood flow in the tributary arteries per sac was calculated in each sac. The aneurysm sac diameter was measured by computed tomography (CT) at 1 year. The patients were divided into two groups according to the presence or absence of sac expansion. RESULTS: Of 155 patients who underwent EVAR, both CT angiography and 4D-flow MRI were performed in 107 patients at 7 days after EVAR. Among them, 39 (36.4%) were found to have a T2EL, of whom 28 were re-evaluated with CT angiography and 4D-flow at 1 year; 7 patients had expanding sacs (expanding group), whereas 21 had nonexpanding sacs (not-expanding group). At 7 days, 28 patients had 80 T2EL vessels detected by 4D-flow MRI, of which 39 vessels (48.8%) had stopped flowing at 1 year (transient vessels); 41 vessels (51.3%) had sustained flow (persistent vessels). The persistent vessels had significantly larger peak flow velocity and amplitude of dynamics of blood flow. The comprehensive analysis of T2EL vessels per sac identified that the amplitude of dynamics of blood flow in the tributary arteries per sac was significantly higher in the expanding group than in the not-expanding group. A receiver operating characteristic curve analysis revealed that the sensitivity and specificity of sac enlargement at a cutoff value of 3750 mm3/min were 85.7% and 76.2%, respectively. CONCLUSIONS: The fate of aneurysm sacs with T2ELs after EVAR has remained difficult to predict. A comprehensive analysis of concurrent multiple T2EL vessels using 4D-flow MRI analysis may enable prediction of the sac expansion after EVAR.


Assuntos
Aorta/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Hemodinâmica , Imageamento por Ressonância Magnética , Imagem de Perfusão/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Velocidade do Fluxo Sanguíneo , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Progressão da Doença , Endoleak/etiologia , Endoleak/fisiopatologia , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
10.
Eur J Cardiothorac Surg ; 56(4): 813-814, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30770716

RESUMO

A 66-year-old woman developed marked haemolytic anaemia 2 years after total aortic arch replacement using a branched Dacron graft. Echocardiography confirmed bicuspid aortic valve stenosis. A four-dimensional flow magnetic resonance imaging revealed a jet flow arising from the aortic valve along with the vortex and turbulent flow inside the kinked prosthetic graft at the ascending aorta. She underwent a reoperation to replace the aortic valve and correct the kinking. The estimated energy loss after intervention was relieved to 2.9 mJ/cardiac cycle from 4.3 mJ/cardiac cycle before intervention. The patient's anaemia resolved immediately after the reoperation.


Assuntos
Anemia Hemolítica/diagnóstico por imagem , Técnicas de Imagem Cardíaca/métodos , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico , Idoso , Aorta Torácica/cirurgia , Implante de Prótese Vascular , Feminino , Humanos
11.
Abdom Radiol (NY) ; 44(4): 1213-1216, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30758533

RESUMO

This study provides the first comprehensive imaging report of human pancreatic eurytremiasis. A 43-year-old man with obstructive jaundice and a pancreatic tumor was referred for diagnosis and treatment. Serum aspartate aminotransferase, alanine aminotransferase, and gamma-glutamyl transpeptidase were elevated. Computed tomography (CT) revealed a multilocular cystic lesion with delayed enhanced area in the pancreas head. On magnetic resonance imaging, the tumor was hyperintense on diffusion-weighted image, and the apparent diffusion coefficient value of the tumor was lower than that of the normal pancreatic parenchyma. Positron emission tomography with 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography (18F-FDG PET/CT) revealed abnormally increased uptake of 18F-FDG in the tumor. A subtotal stomach-preserving pancreaticoduodenectomy was performed on the preoperative diagnosis of pancreatic carcinoma accompanied by branch duct-type intraductal papillary mucinous neoplasm. Multifocal granulomatous lesions with necrotic areas including many parasite eggs were seen on the histology. The final diagnosis was pancreatic eurytremiasis.


Assuntos
Pancreatopatias/diagnóstico por imagem , Pancreatopatias/parasitologia , Doenças Parasitárias/diagnóstico por imagem , Doenças Parasitárias/cirurgia , Adulto , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Masculino , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Pancreatopatias/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia Computadorizada por Raios X/métodos
12.
J Magn Reson Imaging ; 46(2): 595-603, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28152259

RESUMO

PURPOSE: To assess the performance of four-dimensional phase-contrast vastly undersampled isotropic projection reconstruction (4D PC-VIPR) at 3.0T in depicting intrarenal arteries compared with computed tomography angiography (CTA), and its correlation with arterial flowmetry in comparison with Doppler ultrasonography (DUS). MATERIALS AND METHODS: In our prospective single-arm study, subjects were 25 patients who underwent renal transplant-related surgery at our hospital between July 2011 and June 2015. In the morphological study, depictions of renal artery branches delineated by magnetic resonance angiography (MRA)/4D PC-VIPR without gadolinium contrast agent were compared in seven living transplant recipients with the same kidney delineated by CTA in seven living transplant donors. In the flowmetric study, flow velocities in the renal (main stem), segmental, and interlobar arteries during systole and diastole were measured in 12 recipients using noncontrast MRA/4D PC-VIPR, and were compared with those obtained from DUS. RESULTS: Concerning MRA, average confidence levels of delineation rated by six observers for secondary to third level renal artery branches were 82.9-100% and for the fourth to fifth branches were 60.8-89.7% (average kappa value of 0.588 [95% confidence interval: 0.522-0.653]). Total flow velocities measured using 4D PC-VIPR and DUS demonstrated significant correlations during both systole and diastole with acceptable bias (r = 0.902; P < 0.001 in systole and r = 0.734; P < 0.001 in diastole). CONCLUSION: 4D PC-VIPR was useful in generating both morphological and hemodynamic information for evaluation of transplant intrarenal arteries without the need for contrast media. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:595-603.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Rim/diagnóstico por imagem , Artéria Renal/diagnóstico por imagem , Insuficiência Renal/diagnóstico por imagem , Ultrassonografia Doppler , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Meios de Contraste/química , Feminino , Gadolínio/química , Hemodinâmica , Humanos , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Transplante de Rim , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Insuficiência Renal/cirurgia , Reprodutibilidade dos Testes , Fatores de Tempo , Tomografia Computadorizada por Raios X , Transplantados
13.
J Thorac Cardiovasc Surg ; 153(6): 1413-1420.e1, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28027791

RESUMO

OBJECTIVE: Low wall shear stress (WSS) has been reported to be associated with accelerated atherosclerosis, aneurysm growth, or rupture. We evaluated the geometry of aortic arch aneurysms and their relationship with WSS by using the 4-dimensional flow magnetic resonance imaging to better characterize the saccular aneurysms. METHODS: We analyzed the geometry in 100 patients using multiplanar reconstruction of computed tomography. We evaluated WSS and vortex flow using 4-dimensional flow magnetic resonance imaging in 16 of them, which were compared with 8 age-matched control subjects and eight healthy young volunteers. RESULTS: Eighty-two patients had a saccular aneurysm, and 18 had a fusiform aneurysm. External diameter/aneurysm length ratio and sac depth/neck width ratio of the fusiform aneurysms were constant at 0.76 ± 0.18 and 0.23 ± 0.09, whereas those of saccular aneurysms, especially those involving the outer curvature, were higher and more variable. Vortex flow was always present in the aneurysms, resulting in low WSS. When the sac depth/neck width ratio was less than 0.8, peak WSS correlated inversely with luminal diameter even in the saccular aneurysms. When this ratio exceeded 0.8, which was the case only with the saccular aneurysms, such correlation no longer existed and WSS was invariably low. CONCLUSIONS: Fusiform aneurysms elongate as they dilate, and WSS is lower as the diameter is larger. Saccular aneurysms dilate without proportionate elongation, and they, especially those occupying the inner curvature, have higher and variable sac depth/neck width ratio. When this ratio exceeds 0.8, WSS is low regardless of diameter, which may explain their malignant clinical behavior.


Assuntos
Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/fisiopatologia , Hemodinâmica , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Aneurisma da Aorta Torácica/classificação , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/patologia , Aortografia/métodos , Velocidade do Fluxo Sanguíneo , Angiografia por Tomografia Computadorizada , Dilatação Patológica , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Imagem de Perfusão/métodos , Prognóstico , Fluxo Sanguíneo Regional , Estudos Retrospectivos
14.
Intern Med ; 55(9): 1103-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27150862

RESUMO

Left ventricular (LV) involvement in the advanced stage of arrhythmogenic right ventricular cardiomyopathy (ARVC) is a well recognized phenomenon. T wave inversion in the lateral leads has been reported to be an electrocardiographic marker of LV involvement. Variants of ARVC that preferentially affect the left ventricle (left-dominant subtype of arrhythmogenic cardiomyopathy) have recently been recognized. We herein report a case in which an initial electrocardiogram that was similar to the left-dominant subtype of arrhythmogenic cardiomyopathy progressed to definitive ARVC over a period of 7 years. This case supports the hypothesis that LV involvement in ARVC may precede the evident onset of significant RV dysfunction.


Assuntos
Displasia Arritmogênica Ventricular Direita/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Arritmias Cardíacas/fisiopatologia , Displasia Arritmogênica Ventricular Direita/diagnóstico , Cardiomiopatias/fisiopatologia , Progressão da Doença , Eletrocardiografia/métodos , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Disfunção Ventricular Esquerda/diagnóstico
15.
Magn Reson Med Sci ; 15(2): 193-202, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26567758

RESUMO

PURPOSE: Institutional Review Board (IRB)-approved prospective study was conducted to test whether objective and quantitative hemodynamic markers wall shear stress (WSS) and oscillatory shear index (OSI) measured by three-dimensional (3D) cine phase-contrast (PC) can reflect pulmonary arterial hypertension (PAH). PATIENTS AND METHODS: Seventeen consecutive patients of suspected secondary PAH were examined for pulmonary artery pressures (PAPs) with right heart catheterization (RHC) and three-dimensional (3D) cine PC MR. Based on the RHC data, patients were subdivided into two groups of 12 non-PAH (median age of 74.5 years) and 5 PAH (median age of 77 years) patients. Based on 3D cine PC magnetic resonance (MR), hemodynamic parameters including spatially averaged systolic WSS (sWSS), diastolic WSS (dWSS), mean WSS (mWSS), OSI and blood vessel section area (BVSA) at the pulmonary arterial trunk were calculated. Streamline images in the pulmonary arteries were also assessed. All the parameters were compared between non-PAH and PAH groups. RESULTS: sWSS (N/m(2)) and mWSS (N/m(2)) of PAH group was lower than that of non-PAH group (0.594 ± 0.067 vs. 0.961 ± 0.590, P = 0.001), (0.365 ± 0.035 vs. 0.489 ± 0.132, P = 0.027). OSI of PAH group was higher than that of non-PAH (0.214 ± 0.026 vs. 0.130 ± 0.046, P = 0.001). sWSS, mWSS, and dWSS were inversely correlated and OSI was positively correlated to mean PAP or systolic PAP with r values of -0.638 (P = 0.005), -0.643 (P = 0.005), -0.485 (P = 0.049), and 0.625 (P = 0.007); or -0.622 (P = 0.008), -0.629 (P = 0.007), -0.484 (P = 0.049), and 0.594 (P = 0.012), respectively. sWSS was also inversely correlated to BVSA with r value of -0.488 (P = 0.049), and OSI was correlated to BVSA with r value of 0.574 (P = 0.016). Vortex or helical flows were observed more frequently in PAH patients. CONCLUSIONS: The low sWSS and mWSS as well as high OSI measured with 3D cine PC MR could be potential hemodynamic markers for the increased PAP in suspected secondary PAH patients.


Assuntos
Hipertensão Pulmonar , Imagem Cinética por Ressonância Magnética/métodos , Artéria Pulmonar , Idoso , Hemodinâmica/fisiologia , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/fisiopatologia , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia
16.
J Magn Reson Imaging ; 43(2): 384-90, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26149267

RESUMO

PURPOSE: 1) To assess the usefulness of an elastic belt bracing the upper abdomen for reducing the miscalculated areas of the pancreas on 3.0T magnetic resonance elastography (MRE); 2) to test whether MRE can detect difference of stiffness between normal pancreas and the focal pancreatic diseases. MATERIALS AND METHODS: Using an initial eight normal volunteers, miscalculated areas were compared between MRE with the elastic belt and without the belt on 3.0T MRI. Then, using the belt, MRE of the normal pancreas was measured using 14 volunteers and 11 patients with focal pancreatic lesions. RESULTS: The median (95% confidence interval [CI]) percentages of correctly calculated areas were 57.4% (32.9-63.0) with the elastic belt and 35.3% (11.4-60.4) without the belt (P = 0.0078). The stiffness of each pancreatic segment of the normal volunteers (mean ± SE) was 2.37 ± 0.16 kPa for the head, 2.46 ± 0.17 kPa for the body, and 2.58 ± 0.26 kPa for the tail. The stiffness of seven pancreatic cancers was 6.06 ± 0.49 kPa, which was higher than the overall pancreatic stiffness of the normal volunteers (2.47 ± 0.11 kPa, P < 0.0001). Stiffness of the pancreatic lesions in the head of 6.03 ± 0.42 kPa, body of 5.57 ± 0.82 kPa, and tail of 5.9 ± 1.9 kPa were also higher than those of corresponding segments of the normal volunteers (P = 0.0011, 0.0029, and 0.029, respectively). CONCLUSION: With the elastic belt, miscalculation of the pancreatic stiffness was reduced. MRE showed differences of stiffness between normal pancreas and pancreatic lesions.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Técnicas de Imagem por Elasticidade/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Pâncreas/patologia , Neoplasias Pancreáticas/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valores de Referência , Reprodutibilidade dos Testes
17.
Breast Cancer ; 23(6): 844-850, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26474784

RESUMO

BACKGROUND: Optical imaging and spectroscopy using near-infrared light have great potential in the assessment of tumor vasculature. We previously measured hemoglobin concentrations in breast cancer using a near-infrared time-resolved spectroscopy system. The purpose of the present study was to evaluate the effect of the chest wall on the measurement of hemoglobin concentrations in normal breast tissue and cancer. METHODS: We measured total hemoglobin (tHb) concentration in both cancer and contralateral normal breast using a near-infrared time-resolved spectroscopy system in 24 female patients with breast cancer. Patients were divided into two groups based on menopausal state. The skin-to-chest wall distance was determined using ultrasound images obtained with an ultrasound probe attached to the spectroscopy probe. RESULTS: The apparent tHb concentration of normal breast increased when the skin-to-chest wall distance was less than 20 mm. The tHb concentration in pre-menopausal patients was higher than that in post-menopausal patients. Although the concentration of tHb in cancer tissue was statistically higher than that in normal breast, the contralateral normal breast showed higher tHb concentration than cancer in 9 of 46 datasets. When the curves of tHb concentrations as a function of the skin-to-chest wall distance in normal breast were applied for pre- and post-menopausal patients separately, all the cancer lesions plotted above the curves. CONCLUSIONS: The skin-to-chest wall distance affected the measurement of tHb concentration of breast tissue by near-infrared time-resolved spectroscopy. The tHb concentration of breast cancer tissue was more precisely evaluated by considering the skin-to-chest wall distance.


Assuntos
Neoplasias da Mama/sangue , Neoplasias da Mama/diagnóstico por imagem , Hemoglobinas/análise , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Idoso , Feminino , Humanos , Glândulas Mamárias Humanas/irrigação sanguínea , Pessoa de Meia-Idade , Pós-Menopausa , Pré-Menopausa , Valores de Referência , Parede Torácica/anatomia & histologia , Parede Torácica/diagnóstico por imagem
18.
Jpn J Radiol ; 34(2): 130-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26662468

RESUMO

PURPOSE: To help establish consensus on the safe use of contrast media in Japan. MATERIALS AND METHODS: Questionnaires were sent to accredited teaching hospitals with radiology residency programs. RESULTS: The reply rate was 45.4% (329/724). For contrast-induced nephropathy (CIN), chronic and acute kidney diseases were considered a risk factor in 96.7 and 93.6%, respectively, and dehydration in 73.9%. As preventive actions, intravenous hydration (89.1%) and reduction of iodinated contrast media dose (86.9%) were commonly performed. For nephrogenic systemic fibrosis (NSF), chronic and acute kidney diseases were considered risk factors in 98.5 and 90.6%, respectively, but use of unstable gadolinium-based contrast media was considered a risk factor in only 55.6%. A renal function test was always (63.5% in iodinated; 65.7% in gadolinium) or almost always (23.1; 19.8%) performed, and estimated glomerular filtration rate (eGFR) was the parameter most frequently used (80.8; 82.6%). For the patients with risk factors for acute adverse reaction (AAR), steroid premedication or/and change of contrast medium were frequent preventive actions, but intravenous steroid administration immediately before contrast media use was still performed. CONCLUSION: Our questionnaire survey revealed that preventive actions against CIN were properly performed based on patients' eGFR. Preventive actions against NSF and AAR still lacked consensus.


Assuntos
Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Gadolínio/administração & dosagem , Gadolínio/efeitos adversos , Iodo/administração & dosagem , Iodo/efeitos adversos , Nefropatias/induzido quimicamente , Nefropatias/prevenção & controle , Aleitamento Materno , Feminino , Humanos , Japão , Testes de Função Renal , Masculino , Dermopatia Fibrosante Nefrogênica/induzido quimicamente , Dermopatia Fibrosante Nefrogênica/prevenção & controle , Guias de Prática Clínica como Assunto , Gravidez , Fatores de Risco , Inquéritos e Questionários
19.
Nagoya J Med Sci ; 77(3): 399-407, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26412886

RESUMO

Cryosurgery is a minimally invasive treatment for certain types of cancers. Argon-based cryosurgical devices are available at present, however a large compressed gas cylinder with the pressure of 300 atmospheres is needed. To overcome these drawbacks, we developed a new cryosurgical probe measuring about 50 cm in length with separate lumens inside for liquid and gaseous ethylene to be used as a thermosiphon and liquid nitrogen-cooled aluminum thermal storage blocks. The probe needle was 8 cm in length and 3 mm in outer diameter. To investigate the freezing capabilities of our new cryosurgical system we inserted the needle 5cm into a poly-acrylamide gel phantom warmed to 36.5 ℃. Thermal storage blocks made of aluminum, cooled at -196 ℃ in liquid nitrogen, were attached to the condenser of the probe and replaced with thermal storage blocks every 4 to 5 minutes to compensate for warming. We took digital camera images of the ice ball at the needle and measured the temperature in certain locations of the cryoprobe. Ice ball formation started at one minute after cooling. The sizes (longest diameter × minimum diameter) at 10, 20 and 30 minutes after the start of the procedure were 4.5×2.1, 4.5×3.1 and 4.6×3.7 cm, respectively. During the procedure the minimum temperature of the condenser was -85 ℃ and the needle was -65 ℃. This newly developed compact cryosurgical probe with thermosiphon effect and cooled thermal storage blocks created an ice ball that can be used for cryosurgery within 20 minutes.

20.
Magn Reson Med Sci ; 14(1): 73-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25345412

RESUMO

Decreased absolute tumor blood flow (TBF) measured by arterial spin labeling perfusion imaging (ASL-PI) on 3-tesla magnetic resonance imaging demonstrated the reduced size and growth hormone (GH) secretion of a large GH-producing pituitary adenoma in a 32-year-old man in response to octreotide therapy. The study shows the usefulness of ASL-PI in providing a biomarker of the antiangiogenic effect of octreotide.


Assuntos
Inibidores da Angiogênese/farmacologia , Antineoplásicos Hormonais/farmacologia , Imageamento por Ressonância Magnética , Octreotida/farmacologia , Neoplasias Hipofisárias/irrigação sanguínea , Neoplasias Hipofisárias/tratamento farmacológico , Adulto , Hormônio do Crescimento Humano/metabolismo , Humanos , Masculino , Neoplasias Hipofisárias/metabolismo , Reprodutibilidade dos Testes , Marcadores de Spin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA