Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Chim Acta ; 557: 117873, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38493943

RESUMO

BACKGROUND AND AIMS: With the development of novel therapies for advanced malignant melanoma (MM), biomarkers that can accurately reflect the progression of MM are needed. Serum levels of melanin-related indole metabolites such as 5-hydroxy-6-methoxyindole-2-carboxylic acid (5H6MI2C) and 6-hydroxy-5-methoxyindole-2-carboxylic acid (6H5MI2C) are potential biomarkers for MM. Here, we describe the development of a mass spectrometry (MS)-based assay to determine serum levels of 5H6MI2C and 6H5MI2C. MATERIALS AND METHODS: We developed a stable isotope dilution-selective reaction monitoring-MS protocol using liquid chromatography tandem mass spectrometry (LC-MS/MS) to measure human serum 5H6MI2C and 6H5MI2C levels. Analytical evaluations of the method were performed and the method was applied to serum samples from MM patients (n = 81). RESULTS: The method established in this study showed high reproducibility and linearity. This novel method also found that serum 6H5MI2C levels were significantly elevated in patients with metastatic MM compared to those with non-metastatic MM. Unfortunately, 5H6MI2C did not show a comparable significant difference. CONCLUSION: We successfully established measurement methods for serum 5H6MI2C and 6H5MI2C levels using LC-MS/MS. Serum 6H5MI2C levels offer a potential marker for MM.


Assuntos
Melanoma , Neoplasias Cutâneas , Humanos , Melanoma/diagnóstico , Melanoma/patologia , Melaninas , Espectrometria de Massas em Tandem , Cromatografia Líquida , Espectrometria de Massa com Cromatografia Líquida , Reprodutibilidade dos Testes , Indóis , Biomarcadores Tumorais
2.
Proteomics Clin Appl ; 12(3): e1700047, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29349874

RESUMO

PURPOSE: Human serum and plasma are often used as clinical specimens in proteomics analyses, and peptidome profiling of human serum is a promising tool for identifying novel disease-associated biomarkers. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is widely used for peptidomic biomarker discovery. Careful sample collection and handling are required as either can have a profound impact on serum peptidome patterns, yet the effects of preanalytical variables on serum peptidome profiles have not been completely elucidated. The present study investigated the effects of preanalytical variables, including storage temperature, duration (up to 12 months), and thawing methods, on MALDI-TOF MS-based serum peptidome patterns. EXPERIMENTAL DESIGN: Aliquots of serum samples were pretreated with weak cation exchanger magnetic beads using an automated ClinProtRobot system and then analyzed by MALDI-TOF MS. RESULTS: A number of significant differences in peak intensities were observed depending on sample processing variables. CONCLUSIONS AND CLINICAL RELEVANCE: These peaks can be used as sample quality markers to assess the effects of long-term storage on serum peptidome profiles using MALDI-TOF MS.


Assuntos
Peptídeos/sangue , Proteômica/métodos , Manejo de Espécimes , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Adulto , Feminino , Humanos , Masculino , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA