Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 156
Filtrar
1.
Am J Cardiol ; 208: 173-179, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37852127

RESUMO

Global left ventricular (LV) myocardial work (MW) indexes can be recognized at ultrasound imaging from the LV pressure/global longitudinal strain (GLS) loop analysis. A total of 4 indexes, global work index (GWI), global constructive work (GCW), global wasted work (GWW), and global work efficiency (GWE), have been demonstrated to overcome the methodological limitations of GLS and provide useful information on myocardial dysfunction in some clinical settings. Although impaired MW indexes have been demonstrated in patients with transthyretin cardiac amyloidosis (ATTR) or with nonobstructive hypertrophic cardiomyopathy (HCM), there are no comparative studies at present. This study aimed to describe the characteristics of MW in both these clinical settings compared with patients with well-controlled hypertension (HTN). A total of 83 patients, 32 with ATTR (aged 70 ± 11 years, 32% mutated, 68% wild-type, 72% men), 29 with HCM (aged 57 ± 17 years), and 22 HTN controls (aged 56 ± 5.6 years, 59% men) were prospectively enrolled at 2 clinical centers. All participants had New York Heart Association class I or II. Overall, the LV mass index was greater in both study groups than in HTN, whereas the LV ejection fraction (EF) was significantly lower in ATTR compared with other groups. Based on this finding, patients with ATTR were further divided into 2 subgroups: ATTR1 (LVEF ≤0.50), n = 14 (44%) and ATTR2 (LVEF >0.50), n = 18 (56%). Overall, the GWI and GCW were lower in all ATTR patients (mostly in ATTR1) than in the other groups (p <0.001), whereas only small differences in GWE and none in GWW were found among the groups. Of interest, the pairwise comparison and receiver operating characteristic analysis in preserved LVEF patients showed that GWI was a better discriminator of ATTR2 from HCM patients than GLS, with the cut-off value ≤1,419 mm Hg% (89% sensitivity; 55% specificity; p = 0.013). In conclusion, MW analysis was confirmed to be a modern way to investigate myocardial function in patients with hypertrophic phenocopies. GWI and GCW were more impaired in patients with ATTR compared with HCM and HTN controls. Furthermore, this study likely revealed an additional discriminative value of GWI over GLS alone in preserved LVEF settings.


Assuntos
Amiloidose , Cardiomiopatia Hipertrófica , Hipertensão , Masculino , Humanos , Feminino , Pré-Albumina , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Miocárdio , Deformação Longitudinal Global , Volume Sistólico , Função Ventricular Esquerda
2.
J Cardiovasc Dev Dis ; 10(6)2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37367426

RESUMO

Background: Left atrial (LA) function is crucial for assessing left ventricular filling in various cardiovascular conditions. Cardiac Amyloidosis (CA) is characterized by atrial myopathy and LA function impairment, with diastolic dysfunction up to restrictive filling pattern, leading to progressive heart failure and arrhythmias. This study evaluates LA function and deformation using speckle tracking echocardiography (STE) in patients with CA compared to a cohort of patients with sarcomeric Hypertrophic Cardiomyopathy (HCM) and a control group. Methods: We conducted a retrospective, observational study (from January 2019 to December 2022) including a total of 100 patients: 33 with ATTR-CA, 34 with HCMs, and 33 controls. Clinical evaluation, electrocardiograms, and transthoracic echocardiography were performed. Echocardiogram images were analyzed in post-processing using EchoPac software for LA strain quantification, including LA-reservoir, LA-conduit, and LA-contraction strain. Results: The CA group exhibited significantly impaired LA function compared to HCMs and control groups, with LA-reservoir median values of -9%, LA-conduit -6.7%, and LA-contraction -3%; this impairment was consistent even in the CA subgroup with preserved ejection fraction. LA strain parameters correlated with LV mass index, LA volume index, E/e', and LV-global longitudinal strain and were found to be associated with atrial fibrillation and exertional dyspnea. Conclusions: LA function assessed by STE is significantly impaired in CA patients compared to HCMs patients and healthy controls. These findings highlight the potential supportive role of STE in the early detection and management of the disease.

3.
Catheter Cardiovasc Interv ; 100(3): 451-460, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35644994

RESUMO

BACKGROUND: Mitral-valve transcatheter edge-to-edge repair (MV-TEER) is recommended in patients with severe functional mitral regurgitation (FMR) and in those with degenerative mitral regurgitation (DMR) not eligible to traditional surgery. Patients with a history of previous cardiac surgery are considered at high risk for surgical reintervention, but data are lacking regarding procedural and clinical outcomes. OBJECTIVE: aim of this study was to assess the efficacy and clinical results of MV-TEER in patients with previous cardiac surgery enrolled in the "multicentre Italian Society of Interventional Cardiology registry of transcatheter treatment of mitral valve regurgitation" (GIOTTO). METHODS: Patients with previous coronary artery bypass grafting (CABG), surgical aortic valve replacement (AVR), or mitral valve repair (MVR) were included. Those with multiple or combined previous cardiac surgeries were excluded. Clinical follow-up was performed at 30 days, 1 year, and 2 years. The primary endpoint was a composite of death or rehospitalization at 1- and 2-year follow-ups. RESULTS: A total of 330 patients enrolled in the GIOTTO registry were considered (CABG 77.9%, AVR 14.2%, and MVR 7.9%). Most patients showed FMR (66.9%), moderate reduction of left ventricular (LV) ejection fraction, and signs of LV dilation. Procedural and device successes were 94.8% and 97%. At 1 and 2 years, the composite endpoint occurred are 29.1% and 52.4%, respectively. The composite outcome rates were similar across the three subgroups of previous cardiac surgery (p = 0.928) and between the FMR and DMR subgroups (p = 0.850) at 2 years. In a multivariate analysis, residual mitral regurgitation (rMR) ≥2+ was the main predictor of adverse events at 1 year (hazard ratio: 1.54 [95% confidence interval, CI: 1.00-2.38]; p = 0.050). This association was confirmed at 2 years of Kaplan-Meier analysis (p = 0.001). CONCLUSIONS: MV-TEER is effective in these patients, regardless of the subtype of previous cardiac surgery and the MR etiology. An rMR ≥2+ is independently associated with adverse outcomes at 1-year follow-up.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
4.
Int J Cardiol ; 346: 8-12, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34798205

RESUMO

BACKGROUND: The ability of optical coherence tomography (OCT) to recognize intraplaque macrophage infiltration is now well acknowledged. This post-hoc analysis of the CLIMA study aimed to address the clinical impact of the circumferential extension of OCT-defined macrophages and their location at one year follow-up. METHODS: The multicentre CLIMA study enrolled 1003 patients undergoing OCT evaluation of the untreated proximal left anterior descending (LAD) coronary artery. Measurements of circumferential extension of macrophages and measurements of the distance from intima-lumen contour to macrophages string were performed at the plaque cross-section judged as containing the greatest amount of macrophages. The main study endpoint was a composite of cardiac death, myocardial infarction (MI) and/or target vessel revascularization (TVR). RESULTS: Patients with large macrophage arc (p = 0.001) and superficial macrophage arc (p < 0.001) showed a higher one-year incidence of the main one-year composite endpoint. Consistently hypertension (p = 0.018), family history of CAD (p = 0.046), diabetes mellitus (p = 0.036), lower ejection fraction (p = 0.009) and chronic kidney disease (p = 0.019) were more frequently found in patients experiencing the main composite endpoint. At multivariate Cox regression analysis, fibrous cap thickness < 75 µm (HR 2.51, 95% 1.46-4.32), presence of large (HR 1.97, 95%CI 1.16-3.35, p = 0.012) and superficial (HR 1.72, 95%CI 1.02-2.90; p = 0.040) macrophage arc remained independent predictors of the main composite endpoint. Large macrophage arc was associated with target LAD related MI. CONCLUSION: The present post-hoc analysis of the CLIMA showed that the circumferential extension of macrophages and their location are related to a composite endpoint of cardiac death, MI and/or TVR.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Placa Aterosclerótica , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários , Humanos , Macrófagos , Valor Preditivo dos Testes , Fatores de Risco , Tomografia de Coerência Óptica , Resultado do Tratamento
5.
EuroIntervention ; 17(10): 835-847, 2021 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-34796879

RESUMO

Transcatheter aortic valve implantation (TAVI) has revolutionised the treatment of severe, symptomatic aortic stenosis and it is now a proven and effective alternative to surgery for patients regardless of preoperative risk stratification. Nevertheless, the consequent expansion towards younger patients with longer life expectancy focuses attention on long-term considerations. In particular, although the prevalence of coronary artery disease has been shown to decrease with the lowering of estimated risk stratification, the chance of requirement of future coronary interventions after TAVI increases dramatically as a function of patients' life expectancy. To date, however, only a few studies have investigated the feasibility and reproducibility of coronary artery cannulation after TAVI. Different conditions related mainly to aortic root anatomy and specific transcatheter aortic valve (TAV) designs and deployment have been associated with impaired coronary access after TAVI. In the present review, we will examine the conditions that may make coronary access after TAVI more challenging or even impossible.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Cateterismo , Vasos Coronários , Humanos , Reprodutibilidade dos Testes , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
J Am Heart Assoc ; : e019236, 2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33794658

RESUMO

Background Recurrence of mitral regurgitation (MR) after surgical mitral valve repair (SMVR) varies and may require reoperation. Redo mitral valve surgery can be technically challenging and is associated with increased risk of mortality and morbidity. We aimed to assess the feasibility and safety of MitraClip as a treatment strategy after failed SMVR and identify procedure modifications to overcome technical challenges. Methods and Results This international multicenter observational retrospective study collected information for all patients from 16 high-volume hospitals who were treated with MitraClip after failed SMVR from October 29, 2009, until August 1, 2017. Data were anonymously collected. Technical and device success were recorded per modified Mitral Valve Academic Research Consortium criteria. Overall, 104 consecutive patients were included. Median Society of Thoracic Surgeons score was 4.5% and median age was 73 years. At baseline, the majority of patients (82%) were in New York Heart Association class ≥III and MR was moderate or higher in 86% of patients. The cause of MR pre-SMVR was degenerative in 50%, functional in 35%, mixed in 8%, and missing/unknown in 8% of patients. The median time between SMVR and MitraClip was 5.3 (1.9-9.7) years. Technical and device success were 90% and 89%, respectively. Additional/modified imaging was applied in 21% of cases. An MR reduction of ≥1 grade was achieved in 94% of patients and residual MR was moderate or less in 90% of patients. In-hospital all-cause mortality was 2%, and 86% of patients were in New York Heart Association class ≤II. Conclusions MitraClip is a safe and less invasive treatment option for patients with recurrent MR after failed SMVR. Additional/modified imaging may help overcome technical challenges during leaflet grasping.

8.
Eur J Cardiothorac Surg ; 59(3): 586-592, 2021 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-33575794

RESUMO

OBJECTIVES: We sought to develop and validate a novel risk assessment tool for the prediction of 30-day mortality after surgical aortic valve replacement incorporating a patient's frailty. METHODS: Overall, 4718 patients from the multicentre study OBSERVANT was divided into derivation (n = 3539) and validation (n = 1179) cohorts. A stepwise logistic regression procedure and a criterion based on Akaike information criteria index were used to select variables associated with 30-day mortality. The performance of the regression model was compared with that of European System for Cardiac Operative Risk Evaluation (EuroSCORE) II. RESULTS: At 30 days, 90 (2.54%) and 35 (2.97%) patients died in the development and validation data sets, respectively. Age, chronic obstructive pulmonary disease, concomitant coronary revascularization, frailty stratified according to the Geriatric Status Scale, urgent procedure and estimated glomerular filtration rate were independent predictors of 30-day mortality. The estimated OBS AVR score showed higher discrimination (area under curve 0.76 vs 0.70, P < 0.001) and calibration (Hosmer-Lemeshow P = 0.847 vs P = 0.130) than the EuroSCORE II. The higher performances of the OBS AVR score were confirmed by the decision curve, net reclassification index (0.46, P = 0.011) and integrated discrimination improvement (0.02, P < 0.001) analyses. Five-year mortality increased significantly along increasing deciles of the OBS AVR score (P < 0.001). CONCLUSIONS: The OBS AVR risk score showed high discrimination and calibration abilities in predicting 30-day mortality after surgical aortic valve replacement. The addition of a simplified frailty assessment into the model seems to contribute to an improved predictive ability over the EuroSCORE II. The OBS AVR risk score showed a significant association with long-term mortality.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
9.
J Am Coll Cardiol ; 77(1): 1-14, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33413929

RESUMO

BACKGROUND: Surgical aortic valve replacement and transcatheter aortic valve replacement (TAVR) are now both used to treat aortic stenosis in patients in whom life expectancy may exceed valve durability. The choice of initial bioprosthesis should therefore consider the relative safety and efficacy of potential subsequent interventions. OBJECTIVES: The aim of this study was to compare TAVR in failed transcatheter aortic valves (TAVs) versus surgical aortic valves (SAVs). METHODS: Data were collected on 434 TAV-in-TAV and 624 TAV-in-SAV consecutive procedures performed at centers participating in the Redo-TAVR international registry. Propensity score matching was applied, and 330 matched (165:165) patients were analyzed. Principal endpoints were procedural success, procedural safety, and mortality at 30 days and 1 year. RESULTS: For TAV-in-TAV versus TAV-in-SAV, procedural success was observed in 120 (72.7%) versus 103 (62.4%) patients (p = 0.045), driven by a numerically lower frequency of residual high valve gradient (p = 0.095), ectopic valve deployment (p = 0.081), coronary obstruction (p = 0.091), and conversion to open heart surgery (p = 0.082). Procedural safety was achieved in 116 (70.3%) versus 119 (72.1%) patients (p = 0.715). Mortality at 30 days was 5 (3%) after TAV-in-TAV and 7 (4.4%) after TAV-in-SAV (p = 0.570). At 1 year, mortality was 12 (11.9%) and 10 (10.2%), respectively (p = 0.633). Aortic valve area was larger (1.55 ± 0.5 cm2 vs. 1.37 ± 0.5 cm2; p = 0.040), and the mean residual gradient was lower (12.6 ± 5.2 mm Hg vs. 14.9 ± 5.2 mm Hg; p = 0.011) after TAV-in-TAV. The rate of moderate or greater residual aortic regurgitation was similar, but mild aortic regurgitation was more frequent after TAV-in-TAV (p = 0.003). CONCLUSIONS: In propensity score-matched cohorts of TAV-in-TAV versus TAV-in-SAV patients, TAV-in-TAV was associated with higher procedural success and similar procedural safety or mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/mortalidade , Conversão para Cirurgia Aberta/estatística & dados numéricos , Oclusão Coronária/epidemiologia , Feminino , Hemorragia/epidemiologia , Humanos , Masculino , Marca-Passo Artificial/estatística & dados numéricos , Segurança do Paciente , Pontuação de Propensão , Sistema de Registros
10.
Int J Cardiovasc Imaging ; 37(1): 37-45, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32779079

RESUMO

Although optical coherence tomography (OCT) proved to be able to identify macrophage clusters, there are no available data on the possibility to obtain reproducible measurements of their circumferential extension and location. The purpose of the present post-hoc analysis of the CLIMA study was to revise the clinical and demographic variables of patients having coronary plaques with macrophages and to investigate the reproducibility of their quantitative assessment. A total of 577 patients out of 1003 undergoing OCT showed macrophage accumulation. Three groups were identified; group 1 (426 patients) without macrophages, group 2 (296) patients with low macrophage content (less than median value [67°] of circumferential arc) and group 3 (281) with high macrophage content arc [> 67°]. Patients with macrophages (groups 2 and 3) showed a higher prevalence of family history for coronary artery disease and hypercholesterolemia and had a significantly larger body mass index. Furthermore, group 3 had more commonly triple vessel disease and higher value of LDL cholesterol levels compared to the two other groups. The inter-observer agreement for macrophage interpretation was good: R values were 0.97 for the circumferential arc extension, 0.95 for the minimum distance and 0.98 for the mean distance. A non-significant correlation between circumferential extension of macrophages and hsCRP values was found (R = 0.013). Quantitative assessment of macrophage accumulations can be obtained with high reproducibility by OCT. The presence and amount of macrophages are poorly correlated with hsCRP and identify patients with more advanced atherosclerosis and higher LDL cholesterol levels.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Macrófagos/patologia , Placa Aterosclerótica , Tomografia de Coerência Óptica , Idoso , Biomarcadores/sangue , Proteína C-Reativa/análise , LDL-Colesterol/sangue , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros
11.
Eur Heart J Suppl ; 22(Suppl L): L140-L145, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33239989

RESUMO

Aortic stenosis (AS) is one of the most common valvular diseases in developed countries. Transcatheter aortic valve implantation (TAVI) has emerged as alternative to medical treatment or surgical aortic valve replacement (SAVR) in all symptomatic patients with severe AS. In 2002, Cribier performed the first human TAVI through a trans-septal approach in a 57-year-old man with severe AS. Since then, several trials have compared TAVI vs. SAVR over the years. Today, it is superior in terms of mortality to medical therapy in extreme-risk patients, non-inferior or superior to surgery in high-risk patients, and non-inferior to surgery and even superior when transfemoral access is possible in intermediate-risk patients. Interesting results emerged from the latest multicentre trials involving patients with severe AS who were at low risk for death from surgery, demonstrating that this therapy will be offered to younger people in the next future.

12.
JACC Cardiovasc Interv ; 13(15): 1733-1748, 2020 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-32763070

RESUMO

Transcatheter edge-to-edge mitral valve repair is a viable alternative to surgery in patients with severe mitral regurgitation and high surgical risk. Yet the specific group of patients who would optimally benefit from this therapy remains to be determined. Selection of patients for transcatheter strategy is currently based on surgical prognostic scores and technical feasibility. Meanwhile, various clinical, anatomic, and procedural factors have been recently recognized as predictors of adverse outcomes following transcatheter edge-to-edge mitral valve repair, including device failure, recurrent mitral regurgitation, and mortality. Integration of these prognostic factors in the decision-making process of the heart team might improve patient management and outcomes. Herein, the authors review the different factors related to symptomatic status, comorbidity, serum biomarkers, echocardiographic findings, and procedural technique that have been identified as independent predictors of adverse outcome following transcatheter edge-to-edge mitral valve repair and discuss their potential application in everyday clinical practice.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Tomada de Decisão Clínica , Ecocardiografia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/etiologia , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
13.
J Am Coll Cardiol ; 75(16): 1882-1893, 2020 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-32327098

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) use is increasing in patients with longer life expectancy, yet robust data on the durability of transcatheter heart valves (THVs) are limited. Redo-TAVR may play a key strategy in treating patients in whom THVs fail. OBJECTIVES: The authors sought to examine outcomes following redo-TAVR. METHODS: The Redo-TAVR registry collected data on consecutive patients who underwent redo-TAVR at 37 centers. Patients were classified as probable TAVR failure or probable THV failure if they presented within or beyond 1 year of their index TAVR, respectively. RESULTS: Among 63,876 TAVR procedures, 212 consecutive redo-TAVR procedures were identified (0.33%): 74 within and 138 beyond 1 year of the initial procedure. For these 2 groups, TAVR-to-redo-TAVR time was 68 (38 to 154) days and 5 (3 to 6) years. The indication for redo-TAVR was THV stenosis in 12 (16.2%) and 51 (37.0%) (p = 0.002) and regurgitation or combined stenosis-regurgitation in 62 (83.8%) and 86 (62.3%) (p = 0.028), respectively. Device success using VARC-2 criteria was achieved in 180 patients (85.1%); most failures were attributable to high residual gradients (14.1%) or regurgitation (8.9%). At 30-day and 1-year follow-up, residual gradients were 12.6 ± 7.5 mm Hg and 12.9 ± 9.0 mm Hg; valve area 1.63 ± 0.61 cm2 and 1.51 ± 0.57 cm2; and regurgitation ≤mild in 91% and 91%, respectively. Peri-procedural complication rates were low (3 stroke [1.4%], 7 valve malposition [3.3%], 2 coronary obstruction [0.9%], 20 new permanent pacemaker [9.6%], no mortality), and symptomatic improvement was substantial. Survival at 30 days was 94.6% and 98.5% (p = 0.101) and 83.6% and 88.3% (p = 0.335) at 1 year for patients presenting with early and late valve dysfunction, respectively. CONCLUSIONS: Redo-TAVR is a relatively safe and effective option for selected patients with valve dysfunction after TAVR. These results are important for applicability of TAVR in patients with long life expectancy in whom THV durability may be a concern.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias , Reoperação , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Análise de Falha de Equipamento , Feminino , Saúde Global , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Sistema de Registros/estatística & dados numéricos , Reoperação/instrumentação , Reoperação/métodos , Reoperação/estatística & dados numéricos , Análise de Sobrevida , Avaliação de Sintomas/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos
15.
Catheter Cardiovasc Interv ; 95(6): E186-E195, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31423704

RESUMO

OBJECTIVES: We aimed to analyze the baseline features and clinical outcomes of patients younger than 80 years undergoing transfemoral transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR) enrolled in the OBservational Study of Effectiveness of SAVR-TAVR procedures for severe Aortic steNosis Treatment (OBSERVANT) real-world study, focusing on variables guiding Heart Team decision toward TAVI. BACKGROUND: Patients treated with TAVI, independently of surgical risk score, are mostly older than 80 years. METHODS: OBSERVANT is a multicenter, observational, prospective cohort study that enrolled patients with symptomatic severe aortic stenosis (AS) who underwent SAVR or TAVI from December 2010 to June 2012 in 93 Italian participating hospitals. For this analysis, baseline characteristics, therapeutic approach and outcomes up to 5 years of follow-up of 4,801 patients under 80 years of age were collected. Patients were stratified by age classes (<65, 65-74, and 75-79 years). RESULTS: Patients <80 years of age with severe symptomatic AS undergoing TAVI (n = 483) had significantly higher Logistic EuroSCORE (10.84% vs. 5.22%, p < .001) and prevalence of comorbidities compared to subjects undergoing SAVR (n = 4,318). The decision to perform TAVI over SAVR was driven by anatomical factors, mainly previous cardiac surgery (odds ratio [OR] 24.73, confidence interval [CI] 12.71-48.10, p < .001) and the presence of porcelain aorta (OR 17.44, CI 6.67-45.55, p < .001), and clinical factors, mainly moderate-severe frailty score (OR 5.49, CI 3.33-9.07, p < .001), oxygen dependency (OR 7.42, CI 2.75-20.04, p < .001) and need for dialytic treatment (OR 5.24, CI 1.54-17.80, p < .008). Among patients undergoing TAVI, those under 65 years had the highest baseline risk profile (despite a low Logistic EuroSCORE) and the highest 5-year mortality compared to those 65-74 and 75-79-year-old (65.22% vs. 48.54% vs. 55.24%, log-rank p = .061). CONCLUSION: Among patients under 80 years of age with symptomatic severe AS, only 10% underwent TAVI. These patients were at higher baseline risk compared to those undergoing SAVR. The decision to perform TAVI was driven by the presence of both anatomical and clinical factors beyond surgical risk scores. Patients under 65 years of age, despite the low Logistic EuroSCORE, had the highest preoperative risk profile and carried the worse outcome.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Comportamento de Escolha , Tomada de Decisão Clínica , Implante de Prótese de Valva Cardíaca , Seleção de Pacientes , Substituição da Valva Aórtica Transcateter , Fatores Etários , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Comorbidade , Feminino , Nível de Saúde , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 95(3): 398-407, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31609073

RESUMO

AIMS: To evaluate outcomes of transfemoral transcatheter aortic valve implantation (TF-TAVI) using three different new-generation devices. BACKGROUND: Although new generation transcatheter aortic valves (TAVs) have demonstrated to improve procedural outcomes, to date few head-to-head comparisons are available among these devices. METHODS: This is a single center, retrospective study. From September 2014 to February 2018, 389 patients underwent elective TF-TAVI for native, severe aortic stenosis using a new-generation transcatheter aortic valve (TAV) with a preprocedural multi-detector computed tomography assessment. Among these, 346 patients received an Edwards SAPIEN 3 (n = 134), Medtronic Evolut R (n = 111), or Boston ACURATE neo (n = 101) prosthesis. Differences in baseline clinical characteristics between groups were accounted using the propensity score weighting method. RESULTS: The mean age for the entire study cohort was 81.4 ± 5.2 years while the Society of Thoracic Surgery predicted risk of mortality was 4.0 ± 2.5%. After propensity score weighting adjustment, TAVs did not differently impact on 30-day all-cause and cardiovascular mortality. Evolut R device showed an increased risk of permanent pacemaker implantation (PPI) after the procedure (8.3% for SAPIEN 3 vs. 16.7% for Evolut R vs. 2.1% for ACURATE neo, p < .05). At 30 days, patients treated with SAPIEN 3 valve showed a higher mean transvalvular gradient (9.7 ± 7.5 mmHg vs. 6.1 ± 2.4 mmHg vs. 8.4 ± 3.5 mmHg for SAPIEN 3, Evolut R, and ACURATE neo, respectively, p < .01) and a lower rate of more-than-trace paravalvular regurgitation (PVR) (18.8 vs. 47.9 vs. 45.8%, for SAPIEN 3, Evolut R, and ACURATE neo, respectively, p < .01). At 1 year, SAPIEN 3, Evolut R, and ACURATE neo TAVs showed excellent and comparable outcomes with no difference in terms of freedom from major adverse cardiovascular and cerebrovascular event (MACCE) (plog-rank = 0.534). CONCLUSIONS: TAVI using new-generation prostheses was associated with high device success (97.0% vs. 92.8% vs. 95.0% for SAPIEN 3, Evolut R and ACURATE neo, respectively) and low complications rates up to 1 year. Evolut R valve was associated with a higher rate of PPI whereas SAPIEN 3 valve was associated with a higher mean transvalvular gradient and lower rate of more-than-trace PVR. At 1-year, MACCE rates were similar among the three groups.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
Coron Artery Dis ; 31(1): 27-34, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31658146

RESUMO

AIMS: To assess the long-term outcomes of patients treated with sirolimus-eluting Stentys stent in a real-life setting. BACKGROUND: Few data regarding the safety and effectiveness of self-apposing sirolimus-eluting Stentys stent are available. METHODS: 278 patients (30% stable coronary artery disease, 70% acute coronary syndromes, and 54% on unprotected left main) treated with sirolimus eluting Stentys stent were retrospectively included in the self-aPposing, bAlloon-delivered, siRolimus-eluting stent for the Treatment of the coronary Artery disease multicenter registry. Major adverse cardiovascular events (MACE, a composite of cardiac death, myocardial infarction, target lesion revascularization, stent thrombosis) were the primary end-point, single components of MACE were the secondary ones. RESULTS: After 13 months (interquartile range 5-32), MACE was 14%. Stent thrombosis occurred in 3.9% of the patients (2.5% definite stent thrombosis and 1.4% probable stent thrombosis), 66% of them presenting with ST-segment elevation myocardial infarction (STEMI) at admission. Cardiovascular death, target lesion revascularization and myocardial infarction was 4.7%, 8.3%, and 7.2%, respectively. At multivariate analysis, risk of MACE was increased by diabetes (hazard ratios 4.76; P = 0.002) but was not affected by the indication leading to sirolimus-eluting Stentys stent implantation (marked vessel tapering vs. coronary ecstasies, hazard ratios 0.74, P = 0.71). CONCLUSION: Sirolimus-eluting Stentys stent may represent a potential solution for specific coronary anatomies such as bifurcation, ectasic, or tapered vessels. Risk of stent thrombosis appears related to clinical presentation with STEMI and to anatomic features, stressing the importance of the use of intracoronary imaging for self-expandable stents implantation.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Idoso , Antibióticos Antineoplásicos/administração & dosagem , Doenças Cardiovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Estudos Retrospectivos , Sirolimo/administração & dosagem , Trombose/epidemiologia , Resultado do Tratamento
18.
Can J Cardiol ; 35(7): 866-874, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31292085

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is the gold standard for severe valvular aortic stenosis in patients at high/prohibitive surgical risk. This procedure has also been used in patients with previous mitral valve (MV) prostheses, with contrasting outcomes reported. The aim of this study is to describe procedural and early outcomes of patients with previous MV prostheses undergoing TAVR. METHODS: This is a retrospective registry of 154 patients with previous MV prostheses who underwent TAVR across high-volume medical centres at a mean of 11.7 ± 8.4 years after mitral surgery. RESULTS: Mean mitroaortic distance at computed tomography was 9.7 ± 4.8 mm. Procedural success was achieved in 150 (97.4%) patients, with reduction of aortic gradients (42.6 ± 14.2 to 10.0 ± 7.0 mm Hg; P < 0.001). Device success was achieved in 133 (86.3%) patients. MV prosthesis interference by the TAVR device was observed in 2 patients; in both, the mitroaortic distance was <5 mm, with 1 complicated by TAVR prosthesis embolization. Periprocedural complications included 4 (2.6%) cerebrovascular accidents, 10 (6.6%) major vascular complications, 22 (14.4%) severe bleedings, 1 (0.7%) myocardial infarction, and 5 (3.2%) in-hospital deaths (all cases cardiovascular or procedure related). At a median follow-up of 13.5 (interquartile range 1.0 to 36.0) months, 26 (16.9%) deaths occurred; 15 (9.7%) were cardiac related. Late fatal mitral prosthesis thromboses occurred in 2 patients. We recorded a case of fatal hemorrhagic stroke; hospital readmission was observed in 25 (16.2%) patients due to worsening heart failure. CONCLUSIONS: TAVR in patients with previous mitral prostheses appears to be safe and feasible, with good hemodynamic results at 30-day and at longer-term follow-up.


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Feminino , Seguimentos , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Marca-Passo Artificial/estatística & dados numéricos , Readmissão do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Estudos Retrospectivos
19.
Interv Cardiol ; 14(2): 62-69, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31178931

RESUMO

Transcatheter aortic valve implantation (TAVI) has become the standard of care for high-risk and inoperable surgical patients and a valid alternative to surgery for low- and intermediate-risk patients with severe, symptomatic aortic stenosis. It is increasingly being used for younger, lower-risk patients, so it is important to ensure the durability for long-term transcatheter aortic valves. The lack of standard definitions of structural valve degeneration (SVD) had made comparison among studies on prosthetic valve durability problematic. The 2017 standardised definitions of SVD by the European Association of Percutaneous Cardiovascular Intervention), the European Society of Cardiology and the European Association for Cardio-Thoracic Surgery, and the 2018 definitions by the Valve In Valve International Data group, has generated an increased uniformity in evaluations. This article examines the potential mechanisms and rates of SVD of transcatheter bioprostheses and the role of redo TAVI as a treatment option.

20.
Cardiovasc Revasc Med ; 20(5): 371-375, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30857975

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a well-established treatment option for severe aortic stenosis (AS). AS and coronary artery disease frequently coincide, and therefore some patients may require coronary angiography (CAG) and/or intervention (PCI) post-TAVR. Due to valve stent design, most self-expanding prostheses always cover the coronary ostium, and therefore may hinder future access. The objective of this research was to evaluate the incidence, safety and feasibility of CAG/PCI in patients with prior self-expanding TAVR valves. METHODS: Among 2170 patients (age 82 ±â€¯6 years, 43% male) who underwent TAVR with Corevalve or Evolut prostheses, as part of the Italian CoreValve ClinicalService® framework (data from 13 Italian centers), the occurrence of CAG/PCI following TAVR and periprocedural characteristics were examined. RESULTS: During median follow-up of 379 days, 41 patients (1.9%) required CAG and/or PCI (total 46; 16 CAG, 14 PCI, 16 both PCI/CAG). 56.5% of the procedures were performed under emergency/urgency settings. Left system coronary angiography was successfully performed in most cases (28/32, 87.5%), while right coronary angiography was successful only in 50.0% (16/32). PCI procedures (20 for left system, 3 for right system, 4 for graft) were successfully performed in 93.3% (28/30) of the procedures. No CAG/PCI procedure-related complications including prosthesis dislodgment or coronary ostium dissection occurred. CONCLUSIONS: CAG and PCI procedures following CoreValve TAVR is safe and mostly feasible, although the success rate of selective right coronary angiography was relatively low when compared to the left system. Further investigations are required to explore this issue.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Angiografia Coronária/efeitos adversos , Ponte de Artéria Coronária , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/terapia , Bases de Dados Factuais , Estudos de Viabilidade , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA