Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Infection ; 48(3): 375-383, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32100188

RESUMO

PURPOSE: The purpose of this study was to describe left-sided infective endocarditis (LSIE) in persons who inject drugs (PWID) and compare that group to PWID with non-LSIE and to non-PWID with LSIE. METHODS: Retrospective single-center study of adult IE patients from 2011 to 2018. RESULTS: Of the 333 patients in our cohort, 54 were PWID with LSIE, 75 were PWID with non-LSIE, and 204 were non-PWID with LSIE. When comparing LSIE vs non-LSIE in PWID, the LSIE group was older (median age 35 vs 28.5, p < 0.01), had fewer S. aureus infections (59% vs 92%, p < 0.01), was more likely to have cardiac surgery (31% vs 13%, p < 0.01), and had a higher 10-week mortality (22% vs 5%, p < 0.01). When comparing PWID with LSIE to non-PWID with LSIE, the PWID group were younger (median age 35 vs 46, p < 0.01); had more frequent multi-valve involvement (33% vs 19%, p = 0.04), Staphylococcus aureus infections (54% vs 27%, p < 0.01), and previous IE (24% vs 8%, p < 0.01); and experienced more strokes (54% vs 31%, p < 0.01). Ten-week mortality was similar for LSIE in both PWID and non-PWID (24% vs 20%, p = 0.47). CONCLUSIONS: LSIE in PWID is not uncommon. Compared to non-LSIE in PWID, valve surgery is more common and mortality is higher. For reasons that are unclear, stroke is more frequent in LSIE in PWID than in non-PWID with LSIE but mortality is no different.


Assuntos
Usuários de Drogas/estatística & dados numéricos , Endocardite/patologia , Hospitalização/estatística & dados numéricos , Injeções/efeitos adversos , Centros de Atenção Terciária/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Endocardite/etiologia , Feminino , Hospitais de Ensino/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , North Carolina , Estudos Retrospectivos , Adulto Jovem
4.
J Endovasc Ther ; 10(1): 33-41, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12751927

RESUMO

PURPOSE: To review the immediate neurological and bleeding complications associated with the use of glycoprotein (GP) IIb/IIIa inhibitors in patients undergoing extracranial carotid artery stent placement. METHODS: A retrospective review was performed of 550 patients (321 men; mean age 71.1 years, range 28-91) who underwent carotid artery angioplasty and stent placement. Glycoprotein IIb/IIIa inhibitors were given prophylactically along with heparin to 216 patients, whose outcomes were compared to a control group of 334 patients who received intravenous heparin alone. Primary endpoints were the immediate and 30-day neurological complications, including transient ischemic attacks (TIAs), minor and major strokes, and neurologically-related deaths. The secondary endpoint was any abnormal bleeding. RESULTS: The all stroke/neurological death rate in 216 patients treated with heparin and GP IIb/IIIa inhibitors was 6.0% (13 events) compared 2.4% (8 events) in the 334 patients in the heparin-only control group (p=0.0430). Two of the 4 neurologically-related deaths in the GP IIb/IIIa inhibitor group resulted from intracranial hemorrhages; there were no intracranial hemorrhages in the heparin-only group. There was 1 episode of extracranial bleeding in the GP IIb/IIIa inhibitor group treated with embolization. The incidences of significant puncture-site bleeding requiring transfusion were similar in the groups. CONCLUSIONS: Neurological complications following percutaneous carotid artery interventions have been relatively few. The neurological sequelae in carotid stent patients receiving glycoprotein IIb/IIIa inhibitors were more numerous and consequential, which suggests that the use of GP IIb/IIIa inhibitors in carotid stenting should be discouraged.


Assuntos
Angioplastia , Anticorpos Monoclonais/efeitos adversos , Estenose das Carótidas/cirurgia , Fragmentos Fab das Imunoglobulinas/efeitos adversos , Peptídeos/efeitos adversos , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Complicações Pós-Operatórias/epidemiologia , Stents , Tirosina/efeitos adversos , Abciximab , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Eptifibatida , Feminino , Heparina/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/induzido quimicamente , Estudos Retrospectivos , Tirofibana , Resultado do Tratamento , Tirosina/análogos & derivados
5.
J Vasc Surg ; 37(4): 716-23, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12663968

RESUMO

OBJECTIVE: This study was performed to determine whether abdominal aortic aneurysm (AAA) regression is different with various endografts after endovascular repair. METHODS: A four-center retrospective review of size change after endovascular AAA repair was performed. Consecutive patients with at least 1-year follow-up and available imaging studies were included. Three hundred ninety patients received either the Ancure, AneuRx, Excluder, or Talent endograft. AAA size and endoleak status were recorded from computed tomography (CT) scans at the initial postoperative follow-up visit and at 1 and 2 years thereafter. AAA size was defined as the minor axis of the infrarenal aorta on the largest axial section on the two-dimensional CT scan. A change in AAA size of 0.5 cm or greater from baseline was considered clinically significant. The effect of initial size, endoleak, and type of endograft on AAA regression was analyzed. RESULTS: Mean baseline size was significantly greater with Talent endografts and smaller with Excluder endografts. Clinically significant regression in AAA size occurred in nearly three fourths of patients with Ancure and Talent endografts at 2 years. Regression in AAA size was less frequent with the AneuRx (46%) and Excluder (44%) devices. Initial size, endoleak, and endograft type were significant predictors of regression at multivariate analysis at 1 year. However, by 2 years only endograft type was still an independent predictor of AAA shrinkage. CONCLUSIONS: Long-term morphologic changes after endovascular aneurysm repair depend on endograft type.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Pesos e Medidas Corporais/métodos , Humanos , Indução de Remissão , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA