Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 346
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39106079

RESUMO

With their low immunogenicity and excellent deliverability, extracellular vesicles (EVs) are promising platforms for drug delivery systems. In this study, hydrophobic molecule loading techniques were developed via an exchange reaction based on supramolecular chemistry without using organic solvents that can induce EV disruption and harmful side effects. To demonstrate the availability of an exchanging reaction to prepare drug-loading EVs, hydrophobic boron cluster carborane (CB) was introduced to EVs (CB@EVs), which is expected as a boron agent for boron neutron capture therapy (BNCT). The exchange reaction enabled the encapsulation of CB to EVs without disrupting their structure and forming aggregates. Single-particle analysis revealed that an exchanging reaction can uniformly introduce cargo molecules to EVs, which is advantageous in formulating pharmaceuticals. The performance of CB@EVs as boron agents for BNCT was demonstrated in vitro and in vivo. Compared to L-BPA, a clinically available boron agent, and CB delivered with liposomes, CB@EV systems exhibited the highest BNCT activity in vitro due to their excellent deliverability of cargo molecules via an endocytosis-independent pathway. The system can deeply penetrate 3D cultured spheroids even in the presence of extracellular matrices. The EV-based system could efficiently accumulate in tumor tissues in tumor xenograft model mice with high selectivity, mainly via the enhanced permeation and retention effect, and the deliverability of cargo molecules to tumor tissues in vivo enhanced the therapeutic benefits of BNCT compared to the L-BPA/fructose complex. All of the features of EVs are also advantageous in establishing anticancer agent delivery platforms.

2.
J Radiat Res ; 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39167773

RESUMO

This study aimed to identify the required capabilities and workload of medical staff in accelerator-based boron neutron capture therapy (BNCT). From August to September 2022, a questionnaire related to the capabilities and workload in the accelerator-based BNCT was administered to 12 physicians, 7 medical physicists and 7 radiological technologists engaged in BNCT and 6 other medical physicists who were not engaged in BNCT to compare the results acquired by those engaged in BNCT. Only 6-21% of patients referred for BNCT received it. Furthermore, 30-75% of patients who received BNCT were treated at facilities located within their local district. The median required workload per treatment was 55 h. Considering additional workloads for ineligible patients, the required workload reached ~1.2 times longer than those for only eligible patients' treatment. With respect to capabilities, discrepancies were observed in treatment planning, quality assurance and quality control, and commissioning between medical physicists and radiological technologists. Furthermore, the specialized skills required by medical physicists are impossible to acquire from the experience of conventional radiotherapies as physicians engaged in BNCT were specialized not only in radiation oncology, but also in other fields. This study indicated the required workload and staff capabilities for conducting accelerator-based BNCT considering actual clinical conditions. The workload required for BNCT depends on the occupation. It is necessary to establish an educational program and certification system for the skills required to safely and effectively provide BNCT to patients.

3.
J Appl Clin Med Phys ; : e14493, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39189927

RESUMO

BACKGROUND: Neutron beams utilized for performing BNCT are composed of a mixture of neutrons and gamma rays. Although much of the dose delivered to the cancer cells comes from the high LET particles produced by the boron neutron capture reaction, the dose delivered to the healthy tissues from unwanted gamma rays cannot be ignored. With the increase in the number of accelerators for BNCT, a detector system that is capable of measuring gamma ray dose in a mixed neutron/gamma irradiation field is crucial. Currently, BeO TLDs encased in quartz glass are used to measure gamma ray dose in a BNCT irradiation field. However, this type of TLD is no longer commercially available. A replacement dosimetry system is required to perform the recommended ongoing quality assurance of gamma ray measurement for a clinical BNCT system. PURPOSE: The purpose of this study is to evaluate the characteristics of a BeO OSLD detector system under a mixed neutron and gamma ray irradiation field and to assess the suitability of the system for routine quality assurance measurements of an accelerator-based BNCT facility. METHODS: The myOSLD system by RadPro International GmbH was evaluated using the accelerator-based neutron source designed for clinical BNCT (NeuCure BNCT system). The readout constancy, linearity, dose rate effect, and fading effect of the OSLD were evaluated. Free-in-air and water phantom measurements were performed and compared with the TLD results and Monte Carlo simulation results. The PHITS Monte Carlo code was used for this study. RESULTS: The readout constancy was found to be stable over a month-long period and similar to the TLD results. The OSLD readout signal was found to be linear, with a high coefficient of determination (R2 ≥ 0.999) up to a proton charge of 3.6 C. There was no significant signal fading or dose rate dependency. The central axis depth dose and off-axis dose profile measurements agreed with both the TLD and Monte Carlo simulation results, within one standard deviation. CONCLUSION: The myOSLD system was characterized using an accelerator system designed for clinical BNCT. The experimental measurements confirmed the OSLD achieved similar, if not superior to, the currently utilized dosimetry system for routine QA of an accelerator-based BNCT system. The OSLD system would be a suitable replacement for the current TLD system for performing routine QA of gamma ray dose measurement in a BNCT irradiation field.

4.
Cancer Sci ; 115(8): 2774-2785, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38860412

RESUMO

Metastatic spinal tumors are increasingly prevalent due to advancements in cancer treatment, leading to prolonged survival rates. This rising prevalence highlights the need for developing more effective therapeutic approaches to address this malignancy. Boron neutron capture therapy (BNCT) offers a promising solution by delivering targeted doses to tumors while minimizing damage to normal tissue. In this study, we evaluated the efficacy and safety of BNCT as a potential therapeutic option for spine metastases in mouse models induced by A549 human lung adenocarcinoma cells. The animal models were randomly allocated into three groups: untreated (n = 10), neutron irradiation only (n = 9), and BNCT (n = 10). Each mouse was administered 4-borono-L-phenylalanine (250 mg/kg) intravenously, followed by measurement of boron concentrations 2.5 h later. Overall survival, neurological function of the hindlimb, and any adverse events were assessed post irradiation. The tumor-to-normal spinal cord and blood boron concentration ratios were 3.6 and 2.9, respectively, with no significant difference observed between the normal and compressed spinal cord tissues. The BNCT group exhibited significantly prolonged survival rates compared with the other groups (vs. untreated, p = 0.0015; vs. neutron-only, p = 0.0104, log-rank test). Furthermore, the BNCT group demonstrated preserved neurological function relative to the other groups (vs. untreated, p = 0.0004; vs. neutron-only, p = 0.0051, multivariate analysis of variance). No adverse events were observed post irradiation. These findings indicate that BNCT holds promise as a novel treatment modality for metastatic spinal tumors.


Assuntos
Terapia por Captura de Nêutron de Boro , Modelos Animais de Doenças , Neoplasias da Coluna Vertebral , Terapia por Captura de Nêutron de Boro/métodos , Animais , Camundongos , Humanos , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologia , Fenilalanina/análogos & derivados , Fenilalanina/uso terapêutico , Células A549 , Medula Espinal/efeitos da radiação , Medula Espinal/patologia , Linhagem Celular Tumoral , Boro/uso terapêutico , Feminino
5.
Immunity ; 57(6): 1360-1377.e13, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38821052

RESUMO

Limited infiltration and activity of natural killer (NK) and T cells within the tumor microenvironment (TME) correlate with poor immunotherapy responses. Here, we examined the role of the endonuclease Regnase-1 on NK cell anti-tumor activity. NK cell-specific deletion of Regnase-1 (Reg1ΔNK) augmented cytolytic activity and interferon-gamma (IFN-γ) production in vitro and increased intra-tumoral accumulation of Reg1ΔNK-NK cells in vivo, reducing tumor growth dependent on IFN-γ. Transcriptional changes in Reg1ΔNK-NK cells included elevated IFN-γ expression, cytolytic effectors, and the chemokine receptor CXCR6. IFN-γ induced expression of the CXCR6 ligand CXCL16 on myeloid cells, promoting further recruitment of Reg1ΔNK-NK cells. Mechanistically, Regnase-1 deletion increased its targets, the transcriptional regulators OCT2 and IκBζ, following interleukin (IL)-12 and IL-18 stimulation, and the resulting OCT2-IκBζ-NF-κB complex induced Ifng transcription. Silencing Regnase-1 in human NK cells increased the expression of IFNG and POU2F2. Our findings highlight NK cell dysfunction in the TME and propose that targeting Regnase-1 could augment active NK cell persistence for cancer immunotherapy.


Assuntos
Interferon gama , Células Matadoras Naturais , Microambiente Tumoral , Células Matadoras Naturais/imunologia , Células Matadoras Naturais/metabolismo , Animais , Interferon gama/metabolismo , Humanos , Camundongos , Microambiente Tumoral/imunologia , Camundongos Endogâmicos C57BL , Ribonucleases/metabolismo , Ribonucleases/genética , Camundongos Knockout , Transcrição Gênica , Linhagem Celular Tumoral , NF-kappa B/metabolismo
6.
Biomed Phys Eng Express ; 10(4)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38744248

RESUMO

Evaluating neutron output is important to ensure proper dose delivery for patients in boron neutron capture therapy (BNCT). It requires efficient quality assurance (QA) and quality control (QC) while maintaining measurement accuracy. This study investigated the optimal measurement conditions for QA/QC of activation measurements using a high-purity germanium (HP-Ge) detector in an accelerator-based boron neutron capture therapy (AB-BNCT) system employing a lithium target. The QA/QC uncertainty of the activation measurement was evaluated based on counts, reproducibility, and standard radiation source uncertainties. Measurements in a polymethyl methacrylate (PMMA) cylindrical phantom using aluminum-manganese (Al-Mn) foils and aluminum-gold (Al-Au) foils and measurements in a water phantom using gold wire with and without cadmium cover were performed to determine the optimal measurement conditions. The QA/QC uncertainties of the activation measurements were 4.5% for Au and 4.6% for Mn. The optimum irradiation proton charge and measurement time were determined to be 36 C and 900 s for measurements in a PMMA cylindrical phantom, 7.0 C and 900 s for gold wire measurements in a water phantom, and 54 C and 900 s at 0-2.2 cm depth and 3,600 s at deeper depths for gold wire measurements with cadmium cover. Our results serve as a reference for determining measurement conditions when performing QA/QC of activation measurements using HP-Ge detectors at an AB-BNCT employing a lithium target.


Assuntos
Terapia por Captura de Nêutron de Boro , Lítio , Aceleradores de Partículas , Imagens de Fantasmas , Controle de Qualidade , Lítio/química , Terapia por Captura de Nêutron de Boro/métodos , Humanos , Aceleradores de Partículas/instrumentação , Reprodutibilidade dos Testes , Polimetil Metacrilato/química , Nêutrons , Ouro/química , Alumínio/química , Água/química , Radiometria/métodos , Radiometria/instrumentação , Dosagem Radioterapêutica
7.
Crohns Colitis 360 ; 6(2): otae024, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38711858

RESUMO

Background: Real-world data regarding ustekinumab (UST) for ulcerative colitis (UC) particularly in biologics-naïve patients is currently limited. This study aimed to elucidate the real-world effectiveness and safety of UST for UC. Methods: Overall, 150 patients with UC treated with UST from March 2020 to January 2023 were enrolled across 7 referral hospitals. To assess the clinical efficacy and persistence of UST, retrospective analyses were conducted from weeks 8 to 56. Predictive factors concerning the response and persistence of UST were examined through univariate and multivariate analyses. Results: Of the 150 patients, 125 received UST for remission induction, including 36% biologics-naïve. The response and remission rates were 72.8% and 56.0% at week 8 and 73.2% and 63.4% at week 56, respectively. Biologics-naïve patients represented higher response and remission rates at week 8 (84.4% and 73.3%) than those with biologics exposure (66.2% and 46.2%). Patients with prior antitumor necrosis factor (anti-TNF) and vedolizumab (VDZ) exposure had relatively lower response and remission rates (34.5% and 24.1%, respectively). The 1-year cumulative persistence rate was 84.0%. Multivariate analysis revealed that the chronic continuous type and prior anti-TNF and VDZ exposure were negative predictive factors for week 8 responsiveness. Clinical response at week 8 was a predictor of 1-year persistence. Adverse event incidence remained notably low at 6.4%. Conclusions: This study highlights the safety and effectiveness of UST as an induction and maintenance therapy for UC. Chronic continuous type and previous anti-TNF and VDZ exposure negatively contributed to short-term effectiveness, whereas short-term effectiveness provided good persistency.

8.
Neurooncol Adv ; 6(1): vdae062, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38770220

RESUMO

Background: Boron neutron capture therapy (BNCT) is a precise particle radiation therapy known for its unique cellular targeting ability. The development of innovative boron carriers is crucial for the advancement of BNCT technologies. Our previous study demonstrated the potential of PBC-IP administered via convection-enhanced delivery (CED) in an F98 rat glioma model. This approach significantly extended rat survival in neutron irradiation experiments, with half achieving long-term survival, akin to a cure, in a rat brain tumor model. Our commitment to clinical applicability has spurred additional nonclinical pharmacodynamic research, including an investigation into the effects of cannula position and the time elapsed post-CED administration. Methods: In comprehensive in vivo experiments conducted on an F98 rat brain tumor model, we meticulously examined the boron distribution and neutron irradiation experiments at various sites and multiple time intervals following CED administration. Results: The PBC-IP showed substantial efficacy for BNCT, revealing minimal differences in tumor boron concentration between central and peripheral CED administration, although a gradual decline in intratumoral boron concentration post-administration was observed. Therapeutic efficacy remained robust, particularly when employing cannula insertion at the tumor margin, compared to central injections. Even delayed neutron irradiation showed notable effectiveness, albeit with a slightly reduced survival period. These findings underscore the robust clinical potential of CED-administered PBC-IP in the treatment of malignant gliomas, offering adaptability across an array of treatment protocols. Conclusions: This study represents a significant leap forward in the quest to enhance BNCT for the management of malignant gliomas, opening promising avenues for clinical translation.

9.
Int Immunol ; 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38700370

RESUMO

Regnase-1 is an RNase that plays a critical role in negatively regulating immune responses by destabilizing inflammatory mRNAs. Dysfunction of Regnase-1 can be a major cause of various inflammatory diseases with tissue injury and immune cell infiltration into organs. This study focuses on the role of RNase activity of Regnase-1 in developing inflammatory diseases. We have constructed mice with a single point mutation at the catalytic center of Regnase-1 RNase domain, which lacks endonuclease activity. D141N mutant mice demonstrated systemic inflammation, immune cell infiltration into various organs and progressive development of lung granuloma. CD4+ T cells, mainly affected by this mutation, upregulated mTORC1 pathway and facilitated the autoimmune trait in D141N mutation. Moreover, serine/threonine kinase Pim2 contributed to lung inflammation in this mutation. Inhibition of Pim2 kinase activity ameliorated granulomatous inflammation, immune cell infiltration and proliferation in the lungs. Additionally, Pim2 inhibition reduced the expression of adhesion molecules on CD4+ T cells, suggesting a role for Pim2 in facilitating leukocyte adhesion and migration to inflamed tissues. Our findings provide new insights into the role of Regnase-1 RNase activity in controlling immune function and underscore the therapeutic relevance of targeting Pim2 to modulate abnormal immune responses.

10.
Med Phys ; 51(6): 4413-4422, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38669482

RESUMO

BACKGROUND: Monte Carlo simulation code is commonly used for the dose calculation of boron neutron capture therapy. In the past, dose calculation was performed assuming a homogeneous mass density and elemental composition inside the tissue, regardless of the patient's age or sex. Studies have shown that the mass density varies with patient to patient, particularly for those that have undergone surgery or radiotherapy. A method to convert computed tomography numbers into mass density and elemental weights of tissues has been developed and applied in the dose calculation process using Monte Carlo codes. A recent study has shown the variation in the computed tomography number between different scanners for low- and high-density materials. PURPOSE: The aim of this study is to investigate the effect of the elemental composition inside each calculation voxel on the dose calculation and the application of the stoichiometric CT number calibration method for boron neutron capture therapy planning. METHODS: Monte Carlo simulation package Particle and Heavy Ion Transport code System was used for the dose calculation. Firstly, a homogeneous cubic phantom with the material set to ICRU soft tissue (four component), muscle, fat, and brain was modelled and the NeuCure BNCT system accelerator-based neutron source was used. The central axis depth dose distribution was simulated and compared between the four materials. Secondly, a treatment plan of the brain and the head and neck region was simulated using a dummy patient dataset. Three models were generated; (1) a model where only the fundamental materials were considered (simple model), a model where each voxel was assigned a mass density and elemental weight using (2) the Nakao20 model, and (3) the Schneider00 model. The irradiation conditions were kept the same between the different models (irradiation time and irradiation field size) and the near maximum (D1%) and mean dose to the organs at risk were calculated and compared. RESULTS: A maximum percentage difference of approximately 5% was observed between the different materials for the homogeneous phantom. With the dummy patient plan, a large dose difference in the bone (greater than 12%) and region near the low-density material (mucosal membrane, 7%-11%) was found between the different models. CONCLUSIONS: A stoichiometric CT number calibration method using the newly developed Nakao20 model was applied to BNCT dose calculation. The results indicate the importance of calibrating the CT number to elemental composition for each individual CT scanner for the purpose of BNCT dose calculation along with the consideration of heterogeneity of the material composition inside the defined region of interest.


Assuntos
Terapia por Captura de Nêutron de Boro , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Terapia por Captura de Nêutron de Boro/métodos , Calibragem , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Doses de Radiação , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem
11.
Sci Rep ; 14(1): 8265, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594281

RESUMO

Boron neutron capture therapy (BNCT) is a type of targeted particle radiation therapy with potential applications at the cellular level. Spinal cord gliomas (SCGs) present a substantial challenge owing to their poor prognosis and the lack of effective postoperative treatments. This study evaluated the efficacy of BNCT in a rat SCGs model employing the Basso, Beattie, and Bresnahan (BBB) scale to assess postoperative locomotor activity. We confirmed the presence of adequate in vitro boron concentrations in F98 rat glioma and 9L rat gliosarcoma cells exposed to boronophenylalanine (BPA) and in vivo tumor boron concentration 2.5 h after intravenous BPA administration. In vivo neutron irradiation significantly enhanced survival in the BNCT group when compared with that in the untreated group, with a minimal BBB scale reduction in all sham-operated groups. These findings highlight the potential of BNCT as a promising treatment option for SCGs.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias Encefálicas , Glioma , Neoplasias da Medula Espinal , Ratos , Animais , Neoplasias Encefálicas/patologia , Ratos Endogâmicos F344 , Boro , Pesquisa Translacional Biomédica , Compostos de Boro/farmacologia , Glioma/patologia
12.
Magn Reson Med Sci ; 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38447989

RESUMO

PURPOSE: The 8th edition of the American Joint Committee on Cancer staging system included the depth of invasion (DOI) for the T classification of oral cancer. However, no standardized method has been established to clinically measure the DOI. This study aimed to investigate the accuracy of MRI-based DOI for oral tongue squamous cell carcinoma (OTSCC) in each MRI sequence. METHODS: We enrolled 49 patients with histologically proven OTSCC, treated surgically between April 2017 and February 2021. We divided the DOI into three groups using 5 and 10 mm, the thresholds for determining the T stage, and retrospectively evaluated the agreement between MRI-based DOI and pathological DOI (pDOI) for each MRI sequence, axial T1-weighted imaging (T1WI), T2-weighted imaging with fat suppression (FS-T2WI), contrast-enhanced T1WI with fat suppression (CE-T1WI), diffusion-weighted imaging (DWI), and apparent diffusion coefficient (ADC) maps. We also divided the DOI into two groups using 3 mm, the threshold for considering elective neck dissection, and evaluated the overestimation rate of MRI-based DOI in lesions with pDOI ≤ 3 mm. RESULTS: With 5-mm and 10-mm divisions, the accuracy of the DOI assessment was highest on DWI (0.82, weighted kappa = 0.85). With a 3-mm division, the accuracy was also highest on DWI (0.87, kappa = 0.73). The overestimation rate of the MRI-based DOI in lesions with pDOI ≤ 3 mm was lowest on DWI (27.8%). CONCLUSION: DOI on DWI exhibits a comparatively higher rate of concordance with pDOI. DWI may be more useful than other MRI sequences in evaluating the DOI of OTSCC.

13.
Heliyon ; 10(6): e28070, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38545201

RESUMO

Esophageal cancer, which is common among the elderly, has the poorest prognosis among gastrointestinal cancers. Previously, we demonstrated that ferrichrome, produced by the probiotic Lactobacillus casei, exhibited anti-tumor effects in various gastrointestinal cancers, including colorectal and gastric cancers, with minimal effects on non-cancerous intestinal cells. However, it remains unclear whether ferrichrome exerts anti-tumor effects in esophageal cancer. A sulforhodamine B assay revealed that ferrichrome suppressed esophageal adenocarcinoma (OE33, OE19) and squamous cell carcinoma (KYSE70) cells. Ki-67 staining indicated that ferrichrome inhibited the proliferation of esophageal cancer cells. Cell cycle analysis showed that ferrichrome inhibited the DNA synthesis. TUNEL staining revealed that ferrichrome-induced DNA fragmentation. We also confirmed the cleavage of caspase-9 and PARP in ferrichrome-treated cells. Reverse transcription polymerase chain reaction demonstrated an increase in the mRNA of DNA damage-inducible transcript 3 (DDIT-3), a key regulator of programmed cell death, in ferrichrome-treated OE33 cells. In an in vivo OE33 xenograft model, intraperitoneal administration of 5-mg/kg ferrichrome for 14 days resulted in an almost complete inhibition of tumor growth. However, 14 days of intraperitoneal administration of 20-mg/kg 5-fluorouracil (5-FU), but not 20-mg/kg ferrichrome, induced weight loss and myelosuppression in both young and aged mice. Our findings indicate that ferrichrome induces DNA damage-inducible transcript-3, thereby producing anti-tumor effects, including cell cycle arrest and apoptosis, with minimal adverse effects in esophageal cancer cells. This illustrates the high potential of ferrichrome as an anti-tumor drug against esophageal carcinoma.

14.
Cureus ; 16(1): e52137, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38344480

RESUMO

Adrenocortical carcinoma (ACC) is a rare disease with a poor prognosis, which essentially needs an early diagnosis because surgery is the only hope of a cure. On the other hand, primary aldosteronism (PA) is an overproduction of aldosterone from the adrenal glands and is known as one of the most common causes of secondary hypertension and hypokalemia. It is mostly a benign disease. ACC accompanied by PA is extremely rare, which can result in delayed diagnosis and clinical pitfalls. A 56-year-old woman was diagnosed with PA. Mild, symptomatic PA was clinically diagnosed as a right-sided aldosterone-producing adenoma (APA) with adrenal tumor using adrenal vein sampling (AVS). The tumor imaging findings showed abnormalities on computed tomography (CT) in terms of size and attenuation value compared with typical benign adenomas. Twelve months later, the tumor was confirmed to be an ACC with cortisol hypersecretion. The resected ACC specimen did not clearly show positive findings for CYP11B1 or CYP11B2, and disorganized steroid production was suspected. However, the prevalence and clinical characteristics of adrenocortical carcinomas with disorganized steroid production remain unclear. Steroidogenic enzyme immunostaining analysis is important not only for the diagnosis of adrenal adenoma but also for a better understanding of the clinical course of hormone-producing ACC.

15.
Biochem Biophys Res Commun ; 703: 149666, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38377944

RESUMO

The IL-6 amplifier was originally discovered as a mechanism for the enhanced activation of NF-κB in non-immune cells. In the IL-6 amplifier, IL-6-STAT3 and NF-κB stimulation is followed by an excessive production of IL-6, chemokines, and growth factors to develop chronic inflammation preceding the development of inflammatory diseases. Previously, using a shRNA-mediated genome-wide screening, we found that DEAD-Box Helicase 6 (DDX6) is a candidate positive regulator of the amplifier. Here, we investigate whether DDX6 is involved in the pathogenesis of inflammatory diseases via the IL-6 amplifier. We found that DDX6-silencing in non-immune cells suppressed the NF-κB pathway and inhibited activation of the IL-6 amplifier, while the forced expression of DDX6 enhanced NF-κB promoter activity independent of the RNA helicase activity of DDX6. The imiquimod-mediated dermatitis model was suppressed by the siRNA-mediated gene downregulation of DDX6. Furthermore, silencing DDX6 significantly reduced the TNF-α-induced phosphorylation of p65/RelA and IκBα, nuclear localization of p65, and the protein levels of IκBα. Mechanistically, DDX6 is strongly associated with p65 and IκBα, but not TRADD, RIP, or TRAF2, suggesting a novel function of DDX6 as an adaptor protein in the NF-κB pathway. Thus, our findings demonstrate a possible role of DDX6 beyond RNA metabolism and suggest DDX6 is a therapeutic target for inflammatory diseases.


Assuntos
RNA Helicases DEAD-box , NF-kappa B , Regulação da Expressão Gênica , Interleucina-6/metabolismo , NF-kappa B/metabolismo , Inibidor de NF-kappaB alfa/metabolismo , Transdução de Sinais , Fator de Transcrição RelA/metabolismo , Fator de Necrose Tumoral alfa/metabolismo , RNA Helicases DEAD-box/metabolismo
16.
Med Phys ; 51(5): 3711-3724, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38205862

RESUMO

BACKGROUND: In Japan, the clinical treatment of boron neutron capture therapy (BNCT) has been applied to unresectable, locally advanced, and recurrent head and neck carcinomas using an accelerator-based neutron source since June of 2020. Considering the increase in the number of patients receiving BNCT, efficiency of the treatment planning procedure is becoming increasingly important. Therefore, novel and rapid dose calculation algorithms must be developed. We developed a novel algorithm for calculating neutron flux, which comprises of a combination of a Monte Carlo (MC) method and a method based on the removal-diffusion (RD) theory (RD calculation method) for the purpose of dose calculation of BNCT. PURPOSE: We present the details of our novel algorithm and the verification results of the calculation accuracy based on the MC calculation result. METHODS: In this study, the "MC-RD" calculation method was developed, wherein the RD calculation method was used to calculate the thermalization process of neutrons and the MC method was used to calculate the moderation process. The RD parameters were determined by MC calculations in advance. The MC-RD calculation accuracy was verified by comparing the results of the MC-RD and MC calculations with respect to the neutron flux distributions in each of the cubic and head phantoms filled with water. RESULTS: Comparing the MC-RD calculation results with those of MC calculations, it was found that the MC-RD calculation accurately reproduced the thermal neutron flux distribution inside the phantom, with the exception of the region near the surface of the phantom. CONCLUSIONS: The MC-RD calculation method is useful for the evaluation of the neutron flux distribution for the purpose of BNCT dose calculation, except for the region near the surface.


Assuntos
Algoritmos , Terapia por Captura de Nêutron de Boro , Método de Monte Carlo , Nêutrons , Planejamento da Radioterapia Assistida por Computador , Terapia por Captura de Nêutron de Boro/métodos , Nêutrons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Difusão , Dosagem Radioterapêutica , Imagens de Fantasmas , Humanos
17.
Cancer Sci ; 115(1): 283-297, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37923364

RESUMO

Androgen-deprivation therapy is a standard treatment for advanced prostate cancer. However, most patients eventually acquire resistance and progress to castration-resistant prostate cancer (CRPC). In this study, we established new CRPC cell lines, AILNCaP14 and AILNCaP15, from LNCaP cells under androgen-deprived conditions. Unlike most pre-existing CRPC cell lines, both cell lines expressed higher levels of androgen receptor (AR) and prostate-specific antigen (PSA) than parental LNCaP cells. Moreover, these cells exhibited primary resistance to enzalutamide. Since AR signaling plays a significant role in the development of CRPC, PSA promoter sequences fused with GFP were introduced into AILNCaP14 cells to conduct GFP fluorescence-based chemical screening. We identified flavopiridol, a broad-spectrum CDK inhibitor, as a candidate drug that could repress AR transactivation of CRPC cells, presumably through the inhibition of phosphorylation of AR on the serine 81 residue (pARSer81 ). Importantly, this broad-spectrum CDK inhibitor inhibited the proliferation of AILNCaP14 cells both in vitro and in vivo. Moreover, a newly developed liver metastatic model using AILNCaP15 cells revealed that the compound attenuated tumor growth of CRPC harboring highly metastatic properties. Finally, we developed a patient-derived xenograft (PDX) model of CRPC and DCaP CR from a patient presenting therapeutic resistance to enzalutamide, abiraterone, and docetaxel. Flavopiridol successfully suppressed the tumor growth of CRPC in this PDX model. Since ARSer81 was found to be phosphorylated in clinical CRPC samples, our data suggested that broad-spectrum CDK inhibitors might be a potent candidate drug for the treatment of CRPC, including those exhibiting primary resistance to enzalutamide.


Assuntos
Benzamidas , Feniltioidantoína , Neoplasias de Próstata Resistentes à Castração , Masculino , Humanos , Neoplasias de Próstata Resistentes à Castração/metabolismo , Antígeno Prostático Específico , Antagonistas de Androgênios/uso terapêutico , Androgênios , Resistencia a Medicamentos Antineoplásicos , Receptores Androgênicos/metabolismo , Nitrilas/uso terapêutico , Linhagem Celular Tumoral
18.
Med Phys ; 51(2): 1351-1363, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38153111

RESUMO

BACKGROUND: The out-of-field radiation dose for boron neutron capture therapy (BNCT), which results from both neutrons and γ-rays, has not been extensively evaluated. To safely perform BNCT, the neutron and γ-ray distributions inside the treatment room and the whole-body dose should be evaluated during commissioning. Although, certain previous studies have evaluated the whole-body dose in the clinical research phase, no institution providing BNCT covered by health insurance has yet validated the neutron distribution inside the room and the whole-body dose. PURPOSE: To validate the Monte Carlo model of the BNCT irradiation room extended for the whole-body region and evaluate organ-at-risk (OAR) doses using the validated model with a human-body phantom. METHODS: First, thermal neutron distribution inside the entire treatment room was measured by placing Au samples on the walls of the treatment room. Second, neutron and gamma-ray dose-rate distributions inside a human-body water phantom were measured. Both lying and sitting positions were considered. Bare Au, Au covered by Cd (Au+Cd), In, Al, and thermoluminescent dosimeters were arranged at 11 points corresponding to locations of the OARs inside the phantom. After the irradiation, γ-ray peaks emitted from the samples were measured by a high-purity germanium detector. The measured counts were converted to the reaction rate per unit charge of the sample. These measurements were compared with results of simulations performed with the Particle and Heavy Ion Transport code System (PHITS). A male adult mesh-type reference computational phantom was used to evaluate OAR doses in the whole-body region. The relative biological effectiveness (RBE)-weighted doses and dose-volume histograms (DVHs) for each OAR were evaluated. The median dose (D50% ) and near-maximum dose (D2% ) were evaluated for 14 OARs in a 1-h-irradiation process. The evaluated RBE-weighted doses were converted to equivalent doses in 2 Gy fractions. RESULTS: Experimental results within 60 cm from the irradiation center agreed with simulation results within the error bars except at ±20, 30 cm, and those over 70 cm corresponded within one digit. The experimental results of reaction rates or γ-ray dose rate for lying and sitting positions agreed well with the simulation results within the error bars at 8, 4, 11, 7 and 7, 4, 7, 6, 5, 6 out of 11 points, respectively, for Au, Au+Cd, In, Al, and TLD. Among the detectors, the discrepancies in reaction rates between experiment and simulation were most common for Au+Cd, but were observed randomly for measurement points (brain, lung, etc.). The experimental results of γ-ray dose rates were systematically lower than simulation results at abdomen and waist regions for both positions. Extending the PHITS model to the whole-body region resulted in higher doses for all OARs, especially 0.13 Gy-eq increase for D50% of the left salivary gland. CONCLUSION: The PHITS model for clinical BNCT for the whole-body region was validated, and the OAR doses were then evaluated. Clinicians and medical physicists should know that the out-of-field radiation increases the OAR dose in the whole-body region.


Assuntos
Terapia por Captura de Nêutron de Boro , Humanos , Terapia por Captura de Nêutron de Boro/métodos , Cádmio , Simulação por Computador , Método de Monte Carlo , Nêutrons , Radiometria/métodos , Dosagem Radioterapêutica
19.
Pharmaceutics ; 15(12)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38140043

RESUMO

Because of its efficient and robust gene transfer capability, messenger RNA (mRNA) has become a promising tool in various research fields. The lipid nanoparticle (LNP) is considered to be a fundamental technology for an mRNA delivery system and has been used extensively for the development of RNA vaccines against SARS-CoV-2. We recently developed ssPalm, an environmentally responsive lipid-like material, as a component of LNP for mRNA delivery. In this study, a self-degradable unit (phenyl ester) that confers high transfection activity and an immune stimulating unit (vitamin E scaffold) for high immune activation were combined to design a material, namely, ssPalmE-Phe-P4C2, for vaccine use. To design a simple and user-friendly form of an RNA vaccine based on this material, a freeze-drying-based preparation method for producing a ready-to-use-type LNP (LNP(RtoU)) was used to prepare the LNPssPalmE-Phe. The optimization of the preparation method and the lipid composition of the LNPssPalmE-Phe(RtoU) revealed that dioleoyl-sn-glycero phosphatidylethanolamine (DOPE) was a suitable helper lipid for achieving a high vaccination activity of the LNPssPalmE-Phe(RtoU). Other findings indicated that to maintain particle properties and vaccination activity, a 40% cholesterol content was necessary. A single administration of the LNPssPalmE-Phe(RtoU) that contained mRNA-encoding Ovalbumin (mOVA-LNPssPalmE-Phe(RtoU)) demonstrated a significant suppression of tumor progression in a tumor-bearing mouse OVA-expressing cell line (E.G7-OVA). In summary, the LNPssPalmE-Phe(RtoU) is an easy-to-handle drug delivery system (DDS) for delivering mRNA antigens in immunotherapy.

20.
J Neurochem ; 167(6): 753-765, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37975558

RESUMO

Sphingolipidoses are inherited metabolic disorders associated with glycosphingolipids accumulation, neurodegeneration, and neuroinflammation leading to severe neurological symptoms. Lysoglycosphingolipids (lysoGSLs), also known to accumulate in the tissues of sphingolipidosis patients, exhibit cytotoxicity. LysoGSLs are the possible pathogenic cause, but the mechanisms are still unknown in detail. Here, we first show that lysoGSLs are potential inhibitors of phosphoinositide 3-kinase (PI3K) to reduce cell survival signaling. We found that phosphorylated Akt was commonly reduced in fibroblasts from patients with sphingolipidoses, including GM1/GM2 gangliosidoses and Gaucher's disease, suggesting the contribution of lysoGSLs to the pathogenesis. LysoGSLs caused cell death and decreased the level of phosphorylated Akt as in the patient fibroblasts. Extracellularly administered lysoGM1 permeated the cell membrane to diffusely distribute in the cytoplasm. LysoGM1 and lysoGM2 also inhibited the production of phosphatidylinositol-(3,4,5)-triphosphate and the translocation of Akt from the cytoplasm to the plasma membrane. We also predicted that lysoGSLs could directly bind to the catalytic domain of PI3K by in silico docking study, suggesting that lysoGSLs could inhibit PI3K by directly interacting with PI3K in the cytoplasm. Furthermore, we revealed that the increment of lysoGSLs amounts in the brain of sphingolipidosis model mice correlated with the neurodegenerative progression. Our findings suggest that the down-regulation of PI3K/Akt signaling by direct interaction of lysoGSLs with PI3K in the brains is a neurodegenerative mechanism in sphingolipidoses. Moreover, we could propose the intracellular PI3K activation or inhibition of lysoGSLs biosynthesis as novel therapeutic approaches for sphingolipidoses because lysoGSLs should be cell death mediators by directly inhibiting PI3K, especially in neurons.


Assuntos
Fosfatidilinositol 3-Quinases , Esfingolipidoses , Humanos , Camundongos , Animais , Fosfatidilinositol 3-Quinases/metabolismo , Fosfatidilinositol 3-Quinase , Proteínas Proto-Oncogênicas c-akt/metabolismo , Esfingolipidoses/metabolismo , Morte Celular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA