Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2365-2368, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36085979

RESUMO

Temporal interference (TI) stimulation is a technique in which two high frequency sinusoidal electric fields, oscillating at a slightly different frequency are sent into the brain. The goal is to achieve stimulation at the place where both fields interfere. This study uses a simplified version of the Hodgkin - Huxley model to analyse the different parameters of the TI-waveform and how the neuron reacts to this waveform. In this manner, the underlying mechanism of the reaction of the neuron to a TI -signal is investigated. Clinical relevance- This study shows the importance of the parameter choice of the temporal interference waveform and provides insights into the underlying mechanism of the neuronal response to a beating sine for the application of temporal interference stimulation.


Assuntos
Encéfalo , Neurônios , Neurônios/fisiologia
2.
J Neural Eng ; 17(5): 056010, 2020 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-33043898

RESUMO

OBJECTIVE: To design a computationally efficient model for ultrasonic neuromodulation (UNMOD) of morphologically realistic multi-compartmental neurons based on intramembrane cavitation. APPROACH: A Spatially Extended Neuronal Intramembrane Cavitation model that accurately predicts observed fast Charge Oscillations (SECONIC) is designed. A regular spiking cortical Hodgkin-Huxley type nanoscale neuron model of the bilayer sonophore and surrounding proteins is used. The accuracy and computational efficiency of SECONIC is compared with the Neuronal Intramembrane Cavitation Excitation (NICE) and multiScale Optimized model of Neuronal Intramembrane Cavitation (SONIC). MAIN RESULTS: Membrane charge redistribution between different compartments should be taken into account via fourier series analysis in an accurate multi-compartmental UNMOD-model. Approximating charge and voltage traces with the harmonic term and first two overtones results in reasonable goodness-of-fit, except for high ultrasonic pressure (adjusted R-squared ≥0.61). Taking into account the first eight overtones results in a very good fourier series fit (adjusted R-squared ≥0.96) up to 600 kPa. Next, the dependency of effective voltage and rate parameters on charge oscillations is investigated. The two-tone SECONIC-model is one to two orders of magnitude faster than the NICE-model and demonstrates accurate results for ultrasonic pressure up to 100 kPa. SIGNIFICANCE: Up to now, the underlying mechanism of UNMOD is not well understood. Here, the extension of the bilayer sonophore model to spatially extended neurons via the design of a multi-compartmental UNMOD-model, will result in more detailed predictions that can be used to validate or falsify this tentative mechanism. Furthermore, a multi-compartmental model for UNMOD is required for neural engineering studies that couple finite difference time domain simulations with neuronal models. Here, we propose the SECONIC-model, extending the SONIC-model by taking into account charge redistribution between compartments.


Assuntos
Encéfalo , Modelos Neurológicos , Ultrassom , Transferência de Energia , Bicamadas Lipídicas , Neurônios , Técnicas Estereotáxicas
3.
Radiat Prot Dosimetry ; 190(4): 400-411, 2020 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-32909042

RESUMO

The goal of this paper is to experimentally assess the field enhancement and hotspot size of radio frequency electromagnetic fields created by the Maximum Ratio Combining (MRC) precoding scheme using lab measurements at 3.5, 5.5 and 11 GHz. MRC is an adaptive precoding scheme used by Massive Multiple Input Multiple Output systems, one of the enabling techniques of the fifth generation of telecommunications (5G). A virtual antenna array was used to compare MRC with two passive precoding schemes: the Random Phase Model (RPM) and the Centerline Beam Model (CBM). The field enhancement going from CBM to MRC was largest in obstructed line of sight (OLOS), ranging from 1.9 to 7.4 dB. The field enhancement going from RPM to MRC was about 9.5 dB across frequency bands in both line of sight (LOS) and OLOS. The hotspot size, quantified by the full width at half maximum (FWHM), ranged from 0.5 wavelengths to one wavelength.


Assuntos
Campos Eletromagnéticos , Ondas de Rádio
4.
IEEE Trans Biomed Eng ; 66(4): 1155-1164, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30188811

RESUMO

OBJECTIVE: To explore the potential of ultrasonic modulation of plateau-potential generating subthalamic nucleus neurons (STN), by modeling their interaction with continuous and pulsed ultrasonic waves. METHODS: A computational model for ultrasonic stimulation of the STN is created by combining the Otsuka-model with the bilayer sonophore model. The neuronal response to continuous and pulsed ultrasonic waves is computed in parallel for a range of frequencies, duty cycles, pulse repetition frequencies, and intensities. RESULTS: Ultrasonic intensity in continuous-wave stimulation determines the firing pattern of the STN. Three observed spiking modes in order of increasing intensity are low frequency spiking, high frequency spiking with significant spike-frequency and spike-amplitude adaptation, and a silenced mode. Continuous-wave stimulation has little capability to manipulate the saturated spiking rate in the high frequency spiking mode. In contrast, STN firing rates induced by pulsed ultrasound insonication will saturate to the pulse repetition frequency with short latencies, for sufficiently large intensity and repetition frequency. CONCLUSION: Computational results show that the activity of plateau-potential generating STN can be modulated by selection of the stimulus parameters. Low intensities result in repetitive firing, while higher intensities silence the STN. Pulsed ultrasonic stimulation results in a shorter saturation latency and is able to modulate spiking rates. SIGNIFICANCE: Stimulation or suppresion of the STN is important in the treatment of Parkinson's disease, e.g., in deep brain stimulation. This explorative study on ultrasonic modulation of the STN, could be a step in the direction of minimally invasive alternatives to conventional deep brain stimulation.


Assuntos
Estimulação Acústica/métodos , Modelos Neurológicos , Núcleo Subtalâmico , Ondas Ultrassônicas , Simulação por Computador , Humanos , Neurônios/citologia , Neurônios/fisiologia , Neurônios/efeitos da radiação , Núcleo Subtalâmico/citologia , Núcleo Subtalâmico/fisiologia , Núcleo Subtalâmico/efeitos da radiação , Terapia por Ultrassom
5.
J Magn Reson Imaging ; 44(5): 1360-1367, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27043243

RESUMO

PURPOSE: To determine exposure to gradient switching fields of adults and children in a magnetic resonance imaging (MRI) scanner by evaluating internal electric fields within realistic models of adult male, adult female, and child inside transverse and longitudinal gradient coils, and to compare these results with compliance guidelines. MATERIALS AND METHODS: Patients inside x-, y-, and z-gradient coils were simulated using anatomically realistic models of adult male, adult female, and child. The induced electric fields were computed for 1 kHz sinusoidal current with a magnitude of 1 A in the gradient coils. Rheobase electric fields were then calculated and compared to the International Commission on Non-Ionizing Radiation Protection (ICNIRP) 2004 and International Electrotechnical Commission (IEC) 2010 guidelines. The effect of the human body, coil type, and skin conductivity on the induced electric field was also investigated. RESULTS: The internal electric fields are within the first level controlled operating mode of the guidelines and range from 2.7V m-1 to 4.5V m-1 , except for the adult male inside the y-gradient coil (induced field reaches 5.4V m-1 ).The induced electric field is sensitive to the coil type (electric field in the skin of adult male: 4V m-1 , 4.6V m-1 , and 3.8V m-1 for x-, y-, and z-gradient coils, respectively), the human body model (electric field in the skin inside y-gradient coil: 4.6V m-1 , 4.2V m-1 , and 3V m-1 for adult male, adult female, and child, respectively), and the skin conductivity (electric field 2.35-4.29% higher for 0.1S m-1 skin conductivity compared to 0.2S m-1 ). CONCLUSION: The y-gradient coil induced the largest fields in the patients. The highest levels of internal electric fields occurred for the adult male model. J. Magn. Reson. Imaging 2016;44:1360-1367.


Assuntos
Envelhecimento/fisiologia , Campos Magnéticos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Imagem Corporal Total/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Simulação por Computador , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Doses de Radiação , Proteção Radiológica/métodos , Adulto Jovem
6.
Radiat Prot Dosimetry ; 163(1): 58-69, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24729592

RESUMO

Two radio-frequency personal exposimeters (PEMs) worn on both hips are calibrated on a subject in an anechoic chamber. The PEMs' response and crosstalk are determined for realistically polarised incident electric fields using this calibration. The 50 % confidence interval of the PEMs' response is reduced (2.6 dB on average) when averaged over both PEMs. A significant crosstalk (up to a ratio of 1.2) is measured, indicating that PEM measurements can be obfuscated by crosstalk. Simultaneous measurements with two PEMs are carried out in Ghent, Belgium. The highest exposure is measured for Global System for Mobile Communication downlink (0.052 mW m(-2) on average), while the lowest exposure is found for Universal Mobile Telecommunications System uplink (0.061 µW m(-2) on average). The authors recommend the use of a combination of multiple PEMs and, considering the multivariate data, to provide the mean vector and the covariance matrix next to the commonly listed univariate summary statistics, in future PEM studies.


Assuntos
Monitoramento de Radiação/instrumentação , Ondas de Rádio/efeitos adversos , Bélgica , Calibragem , Telefone Celular , Campos Eletromagnéticos/efeitos adversos , Exposição Ambiental , Sistemas de Informação Geográfica , Humanos , Imagens de Fantasmas , Monitoramento de Radiação/estatística & dados numéricos , Incerteza
7.
Bioelectromagnetics ; 34(7): 563-7, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23740872

RESUMO

For the first time, a personal distributed exposimeter (PDE) for radio frequency (RF) measurements is presented. This PDE is designed based on numerical simulations and is experimentally evaluated using textile antennas and wearable electronics. A prototype of the PDE is calibrated in an anechoic chamber. Compared to conventional exposimeters, which only measure in one position on the body, an excellent isotropy of 0.5 dB (a factor of 1.1) and a 95% confidence interval of 7 dB (a factor of 5) on power densities are measured.


Assuntos
Meio Ambiente , Imagens de Fantasmas , Ondas de Rádio , Radiometria/instrumentação , Intervalos de Confiança , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA