Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Rofo ; 185(9): 830-7, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23888471

RESUMO

PURPOSE: Generally, high-resolution MRI of the eye is performed with small loop surface coils. The purpose of this phantom and patient study was to investigate the influence of magnetic field strength and receiver coils on image quality in ocular MRI. MATERIALS AND METHODS: The eyeball and the complex geometry of the facial bone were simulated by a skull phantom with swine eyes. MR images were acquired with two small loop surface coils with diameters of 4 cm and 7 cm and with a multi-channel head coil at 1.5 and 3 Tesla, respectively. Furthermore, MRI of the eye was performed prospectively in 20 patients at 1.5 Tesla (7 cm loop surface coil) and 3 Tesla (head coil). These images were analysed qualitatively and quantitatively and statistical significance was tested using the Wilcoxon-signed-rank test (a p-value of less than 0.05 was considered to indicate statistical significance). RESULTS: The analysis of the phantom images yielded the highest mean signal-to-noise ratio (SNR) at 3 Tesla with the use of the 4 cm loop surface coil. In the phantom experiment as well as in the patient studies the SNR was higher at 1.5 Tesla by applying the 7 cm surface coil than at 3 Tesla by applying the head coil. Concerning the delineation of anatomic structures no statistically significant differences were found. CONCLUSION: Our results show that the influence of small loop surface coils on image quality (expressed in SNR) in ocular MRI is higher than the influence of the magnetic field strength. The similar visibility of detailed anatomy leads to the conclusion that the image quality of ocular MRI at 3 Tesla remains acceptable by applying the head coil as a receiver coil.


Assuntos
Olho/patologia , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Campos Magnéticos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Melanoma/diagnóstico , Imagens de Fantasmas , Neoplasias Uveais/diagnóstico , Adulto , Idoso , Animais , Artefatos , Movimentos Oculares/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Suínos
2.
Rofo ; 185(9): 862-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23888476

RESUMO

PURPOSE: To evaluate the enhancement profile of the macrocyclic contrast medium (CM) gadobutrol in comparison to linear CM Gd-DTPA in DCE-MRI of the prostate. MATERIALS AND METHODS: In total 53 patients with prostata cancer (PCa) were included, who received a radical prostatectomy after multiparametric MRI of the prostate including DCE-MRI. Using circular regions of interests normal peripheral zone (PZ) and PCa foci > 5 mm in diameter (42 and 34 foci in Gd-DTPA and gadobutrol group, respectively) were analysed in DCE-MRI. Enhancement curves (Type I, II and III) and pharmacokinetic parameters were analyzed qualitatively and quantitatively and compared using mixed linear models (two sided p-values < 0.05 were regarded significant). RESULTS: There was no significant difference in frequencies of curve types I, II or III in the normal PZ (p = 0.63) or in PCa foci (p = 0.75). PCa with a Gleason score ≥ 7 had in comparison to Gleason ≤ 6 significantly more often a Wash-Out-curve (Type III) with both CM (p = 0.02). The relative peak enhancement was in the PZ (Gd-DTPA 1.4 a. u. [1.20; 1.59], gadobutrol 1.58 a. u. [1.37; 1.78]) and in PCa foci (Gd-DTPA 1.56 a. u. [1.41; 1.71], gadobutrol 1.76 a. u. [1.59; 1.94]) significantly higher with gadobutrol (p = 0.04). The pharmacokinetic parameters Ktrans und kep were higher in PCa foci than in PZ (p < 0.0001 and p = 0.002, respectively) without significant difference of the parameter values between both CM (p = 0.65). CONCLUSION: [corrected] This study is the first systematic comparison of gadobutrol and Gd-DTPA in DCE-MRI of the prostate. The relative peak enhancement is higher using gadobutrol compared to Gd-DTPA in DCE-MRI. There was no statistically significant difference in curve types or the pharmacokinetic parameters in PCa or normal PZ between both CM.


Assuntos
Meios de Contraste , Gadolínio DTPA , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Compostos Organometálicos , Neoplasias da Próstata/diagnóstico , Idoso , Meios de Contraste/farmacocinética , Gadolínio DTPA/farmacocinética , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Compostos Organometálicos/farmacocinética , Próstata/patologia , Prostatectomia , Neoplasias da Próstata/cirurgia , Sensibilidade e Especificidade
3.
Ann Hematol ; 92(2): 191-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23073603

RESUMO

The majority of patients with myelodysplastic syndrome (MDS) present with anemia and will become dependent on regular transfusions of packed red blood cells (PRBC) with the risk of iron overload (IOL). Liver iron content best reflects the total body iron content, and measurement of liver iron concentration (LIC) by MRI is a validated tool for detection, but data in MDS is rather limited. Here we present the results of a multi-center trial evaluating the efficacy and safety of deferasirox (DFX) in low and intermediate-1 risk MDS patients with transfusion-dependent IOL. Three patients with transfusion frequency of > 4 units PRBC per month were initially treated with 30 mg/kg/day while in 46 patients with a lower transfusion burden deferasirox was initiated at 20 mg/kg/day, due to patient related reasons one patient received DFX in a dose of 6 mg/kg/day only. LIC was measured by MRI at baseline and end of study using the method by St. Pierre et al. The intention to treat population consisted of 50 MDS patients (28 male; 22 female) with a median age of 69 years who were treated with DFX for a median duration of 354 days. Mean daily dose of DFX was 19 mg/kg/day. Median serum ferritin level (SF) at baseline was 2,447 ng/mL and decreased to 1,685 ng/mL (reduction by 31 %) at end of study (p = 0.01). In 7 (13 %) patients the initially chosen dose had to be increased due to unsatisfactory efficacy of chelation therapy. For 21 patients, LIC measurement by liver MRI was performed at baseline and for 19 of these patients at the end of study: mean LIC decreased significantly from 16,8 mg/g dry tissue weight (± 8.3 mg/g dry tissue weight) at study entry to 10,8 mg/g dry tissue weight (± 10.4 mg/g dry tissue weight) at end of study (p = 0.01). Of all patients exposed to the study drug (n = 54), 28 (52 %) did not complete the 12 month study period most commonly due to AEs in 28 % (n = 15) and abnormal laboratory values in 7 % (n = 4), respectively. The most common adverse events (≥ 10 % of all patients) with suspected drug relationship were diarrhea (n = 25, 46 %), nausea (n = 13, 24 %), upper abdominal pain (n = 8, 15 %), serum creatinine increase (n = 16, 30 %) and rash (n = 5, 9 %). Adverse events making dose adjustments or interruption of study drug necessary occurred in 33 patients (61 %). Hematologic improvement according to IWG criteria (2006) was observed in 6 patients (11 %). Initiation of treatment of IOL with DFX depending on the transfusion burden yields sufficient reduction of excess iron indicated by serum ferritin levels and most importantly by liver MRI. The safety profile of DFX was comparable to previous observations.


Assuntos
Benzoatos/uso terapêutico , Terapia por Quelação , Quelantes de Ferro/uso terapêutico , Sobrecarga de Ferro/tratamento farmacológico , Síndromes Mielodisplásicas/terapia , Reação Transfusional , Triazóis/uso terapêutico , Administração Oral , Adulto , Idoso , Idoso de 80 Anos ou mais , Benzoatos/administração & dosagem , Benzoatos/efeitos adversos , Terapia por Quelação/efeitos adversos , Creatinina/sangue , Deferasirox , Toxidermias/etiologia , Feminino , Ferritinas/sangue , Gastroenteropatias/induzido quimicamente , Humanos , Ferro/análise , Quelantes de Ferro/administração & dosagem , Quelantes de Ferro/efeitos adversos , Sobrecarga de Ferro/etiologia , Fígado/química , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Síndromes Mielodisplásicas/epidemiologia , Risco , Resultado do Tratamento , Triazóis/administração & dosagem , Triazóis/efeitos adversos
4.
Prostate Cancer Prostatic Dis ; 15(3): 278-82, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22289782

RESUMO

BACKGROUND: Annual PSA tests have led to a significant increase in the number of prostate cancer (PCa) cases diagnosed. This increased incidence has led to overtreatment of many patients, as current pathology often cannot distinguish latent from aggressive PCa. Studies have shown that the depletion of zinc in prostate cells correlated with cell-line growth rates, and may therefore relate to the progression of PCa. Furthermore, as zinc is normally an inhibitor of citrate oxidation, the reduction of zinc in PCa may cause a decrease in citrate secretion levels in the glandular epithelia of PCa patients. METHODS: Using high-resolution magic angle spinning proton magnetic resonance spectroscopy followed by quantitative histopathology, we investigate unit histo-benign prostate epithelial citrate concentrations in intact tissue samples obtained from 18 patients with pre-surgical PSA values less than 20 ng/ml. Using these data, we evaluate correlations between citrate concentrations and PSA velocities, densities and blood percent-free PSA. RESULTS: We observe different linear patterns between citrate concentrations and histo-benign glandular epithelia from patients of different PSA velocities. More importantly, we obtain a significant correlation between PSA velocity, density and percent-free PSA, and citrate concentrations in unit volume of histo-benign epithelial glands of the peripheral zone. CONCLUSIONS: Low levels of citrate in unit volume represent rapidly increasing PSA values, and, therefore, may be used as an indicator of fast-growing PCa. Thus, tissue samples obtained at the time of biopsy may be evaluated for their citrate concentrations for the prediction of PCa growth rates, allowing for the implementation of alternative treatment options and reducing overtreatment.


Assuntos
Ácido Cítrico/metabolismo , Espectroscopia de Ressonância Magnética , Neoplasias da Próstata/diagnóstico , Adulto , Idoso , Progressão da Doença , Epitélio/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/patologia
5.
Rofo ; 184(2): 105-12, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22179768

RESUMO

PURPOSE: To compare citrate-coated very small superparamagnetic iron oxide particles (VSOP) with gadofosveset trisodium as blood pool contrast agents for cardiac magnetic resonance angiography (CMRA) in pigs. MATERIALS AND METHODS: Animal experiments were approved by the responsible authority. 10 CMRA-like examinations were performed at 1.5 T after administration of VSOP (0.06  mmol Fe/kg; 5 examinations) and gadofosveset trisodium (0.03  mmol Gd/kg; 5 examinations). The CMRA protocol included ECG-gated inversion-recovery-prepared T1-weighted gradient echo imaging (IR-GRE; one slice) and ECG-gated inversion recovery prepared steady state free precession imaging (IR SSFP; one slice) before and 1, 3, 5, 10, 15, 20, 25, 30, 40, 50, and 60  min after injection. At each time point, three different inversion times (TI; 200  msec, 300  msec, and 400  msec) were applied. Contrast-to-noise ratios (CNR) between blood and myocardium were calculated and compared using mixed linear models. RESULTS: No significant differences of CNR were found between IR-GRE and IR SSFP. At 3 and 5  min after contrast agent administration, VSOP showed a significantly higher CNR than gadofosveset trisodium when TI of 200  msec and 300 msec were applied (TI of 200  msec at 3 min: 8.2 ±â€Š0.7 vs. 5.4 ±â€Š0.7; TI of 200  msec at 5 min: 7.9 ±â€Š0.7 vs. 3.5 ±â€Š0.8; TI of 300  msec at 3  min: 11.7 ±â€Š0.7 vs. 8.8 ±â€Š0.8; TI of 300  msec at 5  min: 11.4 ±â€Š0.7 vs. 8.0 ±â€Š0.8; p < 0.05). Moreover, significant differences in favor of VSOP were found for all time points from 10 to 40  min irrespective of TI (p < 0.05). CONCLUSION: VSOP has superior blood-pool properties compared to gadofosveset trisodium resulting in prolonged improvement of CNR on CMRA.


Assuntos
Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Óxido Ferroso-Férrico , Gadolínio , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Compostos Organometálicos , Animais , Sensibilidade e Especificidade , Suínos
6.
Rofo ; 184(5): 420-6, 2012 May.
Artigo em Alemão | MEDLINE | ID: mdl-22198836

RESUMO

Magnetic particle imaging (MPI) displays the spatial distribution and concentration of superparamagnetic iron oxides (SPIOs). It is a quantitative, tomographic imaging method with high temporal and spatial resolution and allows work with high sensitivity yet without ionizing radiation. Thus, it may be a very promising tool for medical imaging. In this review, we describe the physical and technical basics and various concepts for clinical scanners. Furthermore, clinical applications such as cardiovascular imaging, interventional procedures, imaging and therapy of malignancies as well as molecular imaging are presented.


Assuntos
Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Magnetismo , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/terapia , Compostos Férricos/análise , Hemodinâmica , Humanos , Imagem Molecular , Neoplasias/diagnóstico , Neoplasias/terapia
7.
Clin Radiol ; 65(6): 460-4, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20451013

RESUMO

AIM: To evaluate the impact of butylscopolamine on the quality of magnetic resonance imaging (MRI) images of the prostate. MATERIAL AND METHODS: Eighty-two MRI examinations of the prostate were retrospectively analysed. MRI was performed with a combined endorectal/body phased-array coil including proton density-weighted (PD) sequence, T1-weighted turbo spin-echo (TSE)-sequence, and T2-weighted TSE-sequences. Forty milligrams of butylscopolamine was administered intramuscularly in 31 patients (im-group) and intravenously in 30 patients (iv-group). Twenty-one patients did not receive premedication with butylscopolamine (ø-group). Overall image quality, delineation of the bowel wall, and visualization of the prostate, neurovascular bundle, and pelvic lymph nodes were evaluated qualitatively using a five-point scale (from 1=excellent to 5=non-diagnostic/structure not discernible). Motion artefacts within the endorectal coil were quantified by baseline adjusted signal intensities inside the endorectal coil area. RESULTS: Delineation of the bowel wall using the PD-sequence was significantly improved after both intramuscular and intravenous butylscopolamine administration (ø-group: 3.6+/-0.7; im-group: 2.9+/-0.7; iv-group: 2.9+/-0.7; p=0.001). However, there were no significant differences in motion artefacts measured within the endorectal coil (ø-group: 1.18+/-0.14; im-group: 1.15+/-0.11; iv-group: 1.12+/-0.06; p=0.39). There were also no significant differences in qualitative assessment of visualization of the prostate, neurovascular bundle, pelvic lymph nodes, and of overall image quality between the study groups. CONCLUSION: : In conclusion, butylscopolamine had only a small effect on image quality and is not mandatory for MRI of the prostate.


Assuntos
Brometo de Butilescopolamônio/farmacologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Antagonistas Muscarínicos/farmacologia , Próstata/patologia , Neoplasias da Próstata/patologia , Idoso , Artefatos , Humanos , Interpretação de Imagem Assistida por Computador , Injeções Intramusculares , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/diagnóstico , Estudos Retrospectivos
8.
Rofo ; 181(6): 536-42, 2009 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-19353483

RESUMO

PURPOSE: To investigate whether pharmacokinetic MRI parameters "perfusion, blood volume, mean transit time (MTT), interstitial volume, permeability, extraction coefficient, delay, and dispersion" allow the differentiation of low-grade (Gleason score < or = 6) and high-grade (Gleason score > or = 7) prostate cancer. MATERIALS AND METHOD: Forty-two patients with prostate cancer verified by biopsy (PSA 2.7 to 31.4 ng/ml) and scheduled for prostatectomy underwent MRI at 1.5 Tesla using the dynamic contrast-enhanced inversion-prepared dual-contrast gradient echo sequence (temporal resolution, 1.65 s) and a combined endorectal body phased array coil. Parametric maps were computed using a sequential 3-compartment model and the corresponding post-processing algorithms. A total of 41 areas of prostate cancer (15 low-grade, 26 high-grade cancers) in 32 patients were able to be correlated with the prostatectomy specimens and were included in the analysis. RESULTS: Low-grade prostate cancers had a higher mean blood volume (1.76 % vs. 1.64 %, p = 0.039), longer MTT (6.39 s vs. 3.25 s, p < 0.001), and lower mean permeability (2.57 min (-1) vs. 3.86 min (-1), p = 0.011) than high-grade cancers. No statistically significant difference was found for perfusion (p = 0.069), interstitial volume (p = 0.849), extraction coefficient (p = 0.615), delay (p = 0.489), and dispersion (p = 0.306). CONCLUSIONS: Blood volume, MTT, and permeability allow the differentiation of low-grade and high-grade prostate cancer. They may be used to detect cancer progression by MRI in patients managed by active surveillance.


Assuntos
Algoritmos , Meios de Contraste/farmacocinética , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/metabolismo , Adulto , Humanos , Aumento da Imagem/métodos , Masculino , Neoplasias da Próstata/classificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Vet Comp Oncol ; 6(3): 151-61, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19178675

RESUMO

The peripheral washout sign was first described in delayed dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using a small molecular contrast medium in solid lesions of the human breast and liver. It was found to be 100% specific for malignant lesions and could therefore potentially be used as an additional noninvasive diagnostic tool differentiating malignant from benign lesions. The origin of this phenomenon has not yet been explained. The objective of this study was to translate the peripheral washout sign as seen in solid tumours in delayed DCE-MRI in human onto an animal model for further assessment of DCE-MRI characteristics and histological analysis. Small molecular contrast medium DCE-MRI was performed over 42 min in experimental colon carcinoma grown subcutaneously in rats. Qualitative and quantitative analyses for evaluation of presence and characteristics of the peripheral washout sign were accomplished, defining four centripetally distributed tumour zones (central, intermediate, peripheral and marginal). One hundred per cent of the carcinomas demonstrated a peripheral washout sign in DCE-MRI starting at 20 min after bolus injection. Histomorphological analysis was performed for tissue classification and evaluation of microvasculature. Quantitative analysis revealed different enhancement profiles of the four tumour zones. Histology indicated centripetally asymmetric vascularization and vascular endothelial growth factor VEGF/VEGF receptor 2 expression within the tumour tissue. Thus, peripheral washout sign can be translated to an animal model. However, comparison of small molecular contrast medium DCE-MRI with histology revealed that histology alone does not explain the occurrence of the peripheral washout.


Assuntos
Meios de Contraste/farmacologia , Imageamento por Ressonância Magnética/métodos , Neoplasias Experimentais/patologia , Neoplasias Cutâneas/patologia , Animais , Linhagem Celular Tumoral , Masculino , Neoplasias Experimentais/diagnóstico , Ratos , Ratos Endogâmicos , Sensibilidade e Especificidade , Neoplasias Cutâneas/diagnóstico
11.
Radiologe ; 46(7): 574-8, 2006 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-15933848

RESUMO

When patients with an implanted contraceptive device undergo MRI, it must be ensured that the examination involves no risk to the patient (MR safety) and that the diagnosis is not affected by artifacts or the function of the device compromised (MR compatibility). Two basic types of intrauterine devices can be distinguished: the metal-containing/metal-free intrauterine device (IUD) and the hormone-containing implant, the fully metal-free intrauterine system (IUS), as well as the ESSURE insert made of stainless steel, which has been approved for use in Europe since February 2001. The metal-containing and metal-free IUDs and ESSURE are MRI compatible up to a magnetic field strength of 1.5 T. They do not interact in any relevant way with the external magnetic or high-frequency field and the temperature increase is within the physiologic range. The implants merely produce a local signal void with a shape that depends on their orientation relative to the magnetic field lines. At 3 T, only the metal-free IUD and the IUS are MRI safe in terms of the material used. In contrast, metal-containing IUDs and the ESSURE have not yet been fully evaluated in the 3 T field, which is why they represent a contraindication to MRI. No data are available on the MRI compatibility at 3 T for any of these devices.


Assuntos
Queimaduras/etiologia , Queimaduras/prevenção & controle , Segurança de Equipamentos/métodos , Dispositivos Intrauterinos/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Falha de Equipamento , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Medição de Risco , Fatores de Risco
12.
Rofo ; 177(7): 935-9, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15973594

RESUMO

PURPOSE: To differentiate orthotopically implanted prostate cancer from normal prostate tissue using magnetic resonance imaging (MRI) and Gd-DTPA-BMA-enhanced dynamic MRI in the rat model. MATERIAL AND METHODS: Tumors were induced in 15 rats by orthotopic implantation of G subline Dunning rat prostatic tumor cells. MRI was performed 56 to 60 days after tumor cell implantation using T1-weighted spin-echo, T2-weighted turbo SE sequences, and a 2D FLASH sequence for the contrast medium based dynamic study. The interstitial leakage volume, normalized permeability and the permeability surface area product of tumor and healthy prostate were determined quantitatively using a pharmacokinetic model. The results were confirmed by histologic examination. RESULTS: Axial T2-weighted TSE images depicted low-intensity areas suspicious for tumor in all 15 animals. The mean tumor volume was 46.5 mm(3). In the dynamic study, the suspicious areas in all animals displayed faster and more pronounced signal enhancement than surrounding prostate tissue. The interstitial volume and the permeability surface area product of the tumors increased significantly by 420 % (p < 0.001) and 424 % (p < 0.001), respectively, compared to normal prostate tissue, while no significant difference was seen for normalized permeability alone. CONCLUSION: The results of the present study demonstrate that quantitative analysis of contrast-enhanced dynamic MRI data enables differentiation of small, slowly growing orthotopic prostate cancer from normal prostate tissue in the rat model.


Assuntos
Meios de Contraste , Gadolínio DTPA , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Próstata/patologia , Neoplasias da Próstata/patologia , Animais , Diagnóstico Diferencial , Modelos Animais de Doenças , Masculino , Ratos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Aktuelle Urol ; 35(4): 297-306, 2004 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-15459869

RESUMO

Computed tomography (CT) and magnetic resonance imaging (MRI) underwent significant technical advances in the past ten years, especially in the diagnostic evaluation of renal tumors. Either modality can perform unenhanced and contrast enhanced imaging with high resolution display of three-dimensional data sets of the entire abdomen including the arterial and the parenchymatous perfusion phase after injection of contrast medium. Multiplanar reconstructions of these three-dimensional data allow the display in any chosen orientation. The maximum intensity projection can create CT and MR angiograms. For the diagnosis of renal tumors, both modalities offer the possibility of a detailed visualization of both the parenchyma and the arterial and venous vessels, leading to an efficient preoperative work-up. For the MRI diagnosis of the prostate cancer, the achievable accuracy depends on the applied coil technique and on the available clinical information as well as on the experience of the examiner. For the preoperative MRI staging of prostate cancer, the accuracy has been stated to be between 51 % and 97 %.


Assuntos
Carcinoma de Células Renais/diagnóstico , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/diagnóstico , Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico , Tomografia Computadorizada por Raios X , Angiografia , Biópsia , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Rim/patologia , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Próstata/patologia , Neoplasias da Próstata/patologia , Radiografia Abdominal , Tomografia Computadorizada por Raios X/métodos
14.
Rofo ; 176(4): 544-9, 2004 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-15088179

RESUMO

PURPOSE: To evaluate the role of preoperative MRI of the breast in invasive lobular carcinoma (ILC) compared to invasive ductal carcinoma (IDC). MATERIALS AND METHODS: For one year, all patients transferred by the hospital's gynecologic outpatient service for suspicious findings in routine mammography and/or ultrasound (conventional modalities = CM) underwent preoperative MRI of the breast. Retrospective analysis of the histologic findings identified 17 patients with ILC. These were compared with 30 proven IDC patients, chosen by random. The MRI findings of these 2 patient groups were compared with regard to the detection of additional lesions. The average number of additional lesions detected by MRI was compared for significant differences between both groups using the T-test for paired samples. RESULTS: In the 17 patients with ILC, conventional modalities (CM) identified 21malignant lesions whereas MRI detected a total of 30 lesions. At least one additional lesion was detected by MRI in 7 of the 17 patients with ILC. In the 30 patients with IDC, on the other hand, MRI detected an additional lesion in three instances only. In one patient of the ILC group, MRI identified an additional lesion in the contralateral breast that had escaped detection by CM. No additional contralateral lesion was detected by MRI in any of the IDC patients. Benefit of MRI in ILC-Group: The mean numbers of detected malignant lesions differed significantly between diagnosis by MRI and CM in the ILC group (1.77 carcinomas per patient with MRI versus 1.24 with conventional modalities, T-test, p = 0.0078). Benefit of MRI in IDC-Group: although it was possible to find 1.27 carcinomas vs. 1.17 carcinomas per patient in the IDC-Group, this benefit was not statistical significant (T-test, p = 0.0831). CONCLUSION: Preoperative MRI detects multiple additional lesions compared to the ones already known by CM. The higher incidence of multiple lesions in ILC compared to IDC and the difficult diagnosis of ILC in CM might be the reason for the fact that preoperative MRI is particularly useful in patients with ILC.


Assuntos
Neoplasias da Mama/diagnóstico , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Lobular/diagnóstico , Imageamento por Ressonância Magnética , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/cirurgia , Carcinoma Lobular/diagnóstico por imagem , Carcinoma Lobular/patologia , Carcinoma Lobular/cirurgia , Interpretação Estatística de Dados , Feminino , Humanos , Mamografia , Cuidados Pré-Operatórios , Estudos Retrospectivos , Ultrassonografia Mamária
15.
Rofo ; 176(1): 27-36, 2004 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-14712404

RESUMO

Electron beam tomography (EBT) directly competes with other non-invasive imaging modalities, such as multislice computed tomography, magnetic resonance imaging, and echocardiography, in the diagnostic assessment of cardiac diseases. EBT is the gold standard for the detection and quantification of coronary calcium as a preclinical sign of coronary artery disease (CAD). Its standardized examination protocols and the broad experience with this method favor EBT. First results with multislice CT indicate that this new technology may be equivalent to EBT for coronary calcium studies. The principal value of CT-based coronary calcium measurements continues to be an issue of controversy amongst radiologists and cardiologists due to lack of prospective randomized trials. Coronary angiography with EBT is characterized by a high negative predictive value and, in addition, may be indicated in some patients with manifest CAD. It remains to be shown whether coronary angiography with multislice CT is reliable and accurate enough to be introduced into the routine work-up, to replace some of the many strictly diagnostic coronary catheterizations in Germany and elsewhere. Assessment of coronary stent patency with EBT is associated with several problems and in our opinion cannot be advocated as a routine procedure. EBT may be recommended for the evaluation of coronary bypasses to look for bypass occlusions and significant stenoses, which, however, can be equally well achieved with multislice CT. Quantification of myocardial perfusion with EBT could not replace MRI or other modalities in this field. EBT has proven to be accurate, reliable and in some instances equivalent to MRI, which is the gold standard for the quantitative and qualitative evaluation of cardiac function. Some disadvantages, not the least of which is the limited distribution of electron beam scanners, favor MRI for functional assessment of the heart.


Assuntos
Angiografia Coronária , Ponte de Artéria Coronária , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Angioplastia Coronária com Balão , Calcinose/diagnóstico por imagem , Cateterismo Cardíaco , Doença das Coronárias/diagnóstico , Feminino , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/diagnóstico por imagem , Coração/fisiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Stents
16.
Rofo ; 175(6): 752-65, 2003 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-12811686

RESUMO

A wide range of applications for superparamagnetic iron oxide (SPIO) particles as contrast media for MRI has emerged over the last 15 years. SPIO particles can be manufactured with different particle sizes and surface coatings. Large SPIO particles (50-150 nm) predominantly produce a signal decrease or T2 -shortening and are used as contrast media for MRI of the liver and spleen. They have a high accuracy, especially in detecting liver metastases (approved for clinical use: AMI-25 (Endorem or Ferridex), SHU-555A (Resovist)). Smaller particles (about 20 nm in diameter) show a different organ distribution and have a potential for improving noninvasive lymph node assessment or characterizing vulnerable atherosclerotic plaques (in clinical trials: AMI-227 [Sinerem or Combidex]). Particles with an optimized T1-relaxivity and prolonged intravascular circulation time can be used as blood pool contrast media for MR angiography. The currently investigated indications are MR angiography of the trunk, peripheral vessels, and coronary arteries (e.g., SHU-555 C (Supravist), VSOP-C 184). Other applications of small SPIO particles include MRI of the bone marrow and the determination of perfusion parameters in tumors or other tissues like the myocardium. SPIO particles with a modified coat can be used in so-called molecular imaging, such as receptor-directed imaging, cell labeling for in-vivo monitoring of cell migration, e.g., stem cell labeling, and labeling of gene constructs for localization in genetic therapy. In tumor therapy SPIO particles can serve as mediators for hyperthermia. SPIO is a powerful MR contrast medium with manifold applications ranging from diagnostic imaging to molecular medicine.


Assuntos
Meios de Contraste , Compostos Férricos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/tendências , Imageamento por Ressonância Magnética/tendências , Animais , Óxido Ferroso-Férrico , Previsões , Humanos , Tamanho da Partícula , Ratos , Sensibilidade e Especificidade
17.
Rofo ; 175(6): 799-805, 2003 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-12811693

RESUMO

PURPOSE: To compare three MRI coil systems in terms of image quality, delineation of prostate cancer, and tumor staging. MATERIALS AND METHODS: 49 patients with prostate cancer underwent MRI at 1.5 Tesla using a combination of an endorectal coil with a phased-array body coil (combination coil) prior to radical prostatectomy. Images were reconstructed from the data sets acquired with the endorectal coil alone and from those acquired with the combined coil. In addition, 19 patients of the study patients were examined with the body phased-array coil alone without the endorectal coil. The prostate was imaged at a slice thickness of 3 mm using axial and coronal T 2 -weighted sequences and an axial T 1 -weighted sequence. Preoperative analysis of all images acquired was done to determine the accuracy of MRI in local staging of prostate cancer. An additional retrospective analysis served to compare the different coil systems in terms of overall image quality, delineation and localization of the tumor, and criteria for local staging of prostate cancer. RESULTS: Preoperative analysis showed MRI to have an accuracy of 59 % in local tumor staging. Retrospective coil-by-coil analysis demonstrated image quality and tumor delineation to be best for the combination coil and the endorectal coil. Regarding the staging criteria for transcapsular tumor extension and infiltration of adjacent organs, a significant advantage of the combination coil compared to the endorectal coil was identified only for the criterion of smooth bulging. In addition, the endorectal coil and the combination coil were found to be superior to the body phased-array coil in assessing 15 of 17 criteria for local tumor staging but the differences were not significant. CONCLUSION: In view of the achieved superior image quality, the combination coil or the endorectal coil is the preferred method for staging prostate cancer.


Assuntos
Aumento da Imagem/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Neoplasias da Próstata/diagnóstico , Idoso , Humanos , Excisão de Linfonodo , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Próstata/patologia , Antígeno Prostático Específico/sangue , Prostatectomia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos , Sensibilidade e Especificidade
18.
Acta Radiol ; 44(2): 172-6, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12694104

RESUMO

PURPOSE: To evaluate the capability of bright-blood cine MR to directly visualize the leaflets of the valve replacement in pulmonary position following Ross operation. MATERIAL AND METHODS: Long and short axis views of the pulmonary valve were obtained in 10 normal subjects and 14 patients after Ross operation. Valve morphology and function were analyzed and signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Flow measurements were performed in the pulmonary trunk to assess pulmonary regurgitation. RESULTS: In all subjects, tricuspid morphology of the pulmonary valve was visualized. SNR of the leaflets in normal subjects (9.8 +/- 3.0) and in patients after Ross operation (7.5 +/- 2.2) differed significantly from blood (12.6 +/- 3.2 and 11.3 +/- 2.5, respectively, p < 0.05). Valvular regurgitation was seen in 5 patients as an insufficient closure of the valve which was confirmed by flow measurements. CONCLUSION: Cine MR enables in-plane visualization of the pulmonary valve and allows for functional and morphological evaluation in patients after pulmonary valve surgery.


Assuntos
Imagem Cinética por Ressonância Magnética , Valva Pulmonar/anatomia & histologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
19.
Rofo ; 175(3): 342-5, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12635010

RESUMO

AIM: To investigate the use of iodine-based contrast media in digital full-field mammography. METHODS: After performing initial phantom studies, seven patients underwent digital mammography (Senographe 2000D, GE Medical Systems, Milwaukee, USA) using a specially filtered beam before as well as 60, 120, and 180 seconds after injection of 80 ml of iodine contrast medium (Ultravist 370, Schering AG, Germany). The precontrast mammograms were then subtracted from the postcontrast mammograms and the resulting images compared with a contrast-enhanced dynamic MRI study, performed on all women. RESULTS: Contrast medium accumulation within the tumors was visualized with a good quality in all cases. The conditions under which successful contrast-enhanced digital mammography can be performed were determined in phantom studies. CONCLUSIONS: Contrast-enhanced digital mammography has a potential for improving the visualization of breast tumors in mammography using special beam filtering, adjusted x-ray parameters, proper timing, and suitable subtraction software.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Iohexol/análogos & derivados , Mamografia/métodos , Intensificação de Imagem Radiográfica , Meios de Contraste , Feminino , Humanos , Imagens de Fantasmas , Doses de Radiação
20.
Urologe A ; 42(2): 187-96, 2003 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-12607086

RESUMO

Considerable technical advances have been made in computed tomography (CT) and magnetic resonance imaging (MRI) over the last 10 years. Both modalities allow for high-resolution imaging of the entire abdomen before as well as during the arterial and parenchymal perfusion phase after intravenous contrast medium administration. Multiplanar reconstructions of the three-dimensional source data sets yield views in any spatial orientation. Maximum intensity projections enable the generation of CT or MR angiographies as well as CT or MR urographies from delayed images. Thus, both modalities today allow for comprehensive diagnostic evaluation of renal disease by a single examination comprising detailed visualization of the parenchyma as well as of arterial and venous vessels and assessment of excretion. CT and MRI thus enable efficient preoperative diagnostic assessment in particular in patients with renal masses.


Assuntos
Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Nefropatias/diagnóstico , Neoplasias Renais/diagnóstico , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Rim/anormalidades , Rim/patologia , Angiografia por Ressonância Magnética , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA