Phys Med ; 37: 9-15, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28535921

RESUMO

PURPOSE: To assess out-of-field dose using three different variants of LiF thermoluminescence dosimeters (TLD) for ten patients who underwent stereotactic ablative body radiotherapy (SABR) for primary renal cell carcinoma (RCC) and compare with treatment planning system (TPS) dose calculations. METHODS AND MATERIALS: Thermoluminescent dosimeter (TLD) measurements were conducted at 20, 30, 40 and 50cm from isocentre on ten patients undergoing SABR for primary RCC. Three types of high-sensitivity LiF:Mg,Cu,P TLD material with different 6Li/7Li isotope ratios were used. Patient plans were calculated using Eclipse Anisotropic Analytical Algorithm (AAA) for clinical evaluation and recalculated using Pencil Beam Convolution (PBC) algorithm for comparison. RESULTS: Both AAA and PBC showed diminished accuracy for photon doses at increasing distance out-of-field. At 50cm, measured photon dose was 0.3cGy normalised to a 10Gy prescription on average with only small variation across all patients. This is likely due to the leakage component of the out-of-field dose. The 6Li-enriched TLD materials showed increased signal attributable to additional neutron contribution. CONCLUSION: LiF:Mg,Cu,P TLD containing 6Li is sensitive enough to measure out-of-field dose 50cm from isocentre however will over-estimate the photon component of out-of-field dose in high energy treatments due to the presence of thermal neutrons. 7Li enriched materials which are insensitive to neutrons are therefore required for accurate photon dosimetry. Neutron signal has been shown here to increase with MUs and is higher for patients treated using certain non coplanar beam arrangements. Further work is required to convert this additional neutron signal to dose.


Assuntos
Dosimetria in Vivo , Neoplasias Renais/radioterapia , Dosimetria Termoluminescente , Humanos , Nêutrons , Fótons , Radiometria , Dosagem Radioterapêutica
2.
Radiat Prot Dosimetry ; 172(4): 327-332, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26598738

RESUMO

Production of radioisotopes in medical linear accelerators (linacs) is of concern when the beam energy exceeds the threshold for the photonuclear interaction. Staff and patients may receive a radiation dose as a result of the induced radioactivity in the linac. Gamma-ray spectroscopy was used to identify the isotopes produced following the delivery of 18 MV photon beams from a Varian 21EX and an Elekta Synergy. The prominent radioisotopes produced include 187W, 63Zn, 56Mn, 24Na and 28Al in both linac models. The dose rate was measured at the beam exit window (12.6 µSv in the first 10 min) following 18 MV total body irradiation (TBI) beams. For a throughput of 24 TBI patients per year, staff members are estimated to receive an annual dose of up to 750 µSv at the patient location. This can be further reduced to 65 µSv by closing the jaws before re-entering the treatment bunker.


Assuntos
Raios gama , Nêutrons/efeitos adversos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Aceleradores de Partículas/instrumentação , Radioterapia de Alta Energia/efeitos adversos , Irradiação Corporal Total/métodos , Pessoal de Saúde , Humanos , Método de Monte Carlo , Fótons , Monitoramento de Radiação , Proteção Radiológica , Dosagem Radioterapêutica , Medição de Risco
3.
Australas Phys Eng Sci Med ; 37(4): 791-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25262165

RESUMO

Temporally varying light intensity during acquisition of projection images in an optical CT scanner can potentially be misinterpreted as physical properties of the sample. This work investigated the impact of LED light source intensity instability on measured attenuation coefficients. Different scenarios were investigated by conducting one or both of the reference and data scans in a 'cold' scanner, where the light source intensity had not yet stabilised. Uniform samples were scanned to assess the impact on measured uniformity. The orange (590 nm) light source decreased in intensity by 29 % over the first 2 h, while the red (633 nm) decreased by 9 %. The rates of change of intensity at 2 h were 0.1 and 0.03 % respectively over a 5 min period-corresponding to the scan duration. The normalisation function of the reconstruction software does not fully account for the intensity differences and discrepancies remain. Attenuation coefficient inaccuracies of up to 8 % were observed for data reconstructed from projection images acquired with a cold scanner. Increased noise was observed for most cases where one or both of the scans was acquired without sufficient warm-up. The decrease in accuracy and increase in noise were most apparent for data reconstructed from reference and data scans acquired with a cold scanner on different days.


Assuntos
Artefatos , Imageamento Tridimensional/instrumentação , Radiometria/instrumentação , Radioterapia Guiada por Imagem/instrumentação , Semicondutores , Tomografia Óptica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Australas Phys Eng Sci Med ; 37(1): 15-23, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24318958

RESUMO

Leakage radiation from linear accelerators can make a significant contribution to healthy tissue dose in patients undergoing radiotherapy. In this work thermoluminescent dosimeters (LiF:Mg,Cu,P TLD chips) were used in a focused lead cone loaded with TLD chips for the purpose of evaluating leakage dose at the patient plane. By placing the TLDs at one end of a stereotactic cone, a focused measurement device is created; this was tested both in and out of the primary beam of a Varian 21-iX linac using 6 MV photons. Acrylic build up material of 1.2 cm thickness was used inside the cone and measurements made with either one or three TLD chips at a given distance from the target. Comparing the readings of three dosimeters in one plane inside the cone offered information regarding the orientation of the cone relative to a radiation source. Measurements in the patient plane with the linac gantry at various angles demonstrated that leakage dose was approximately 0.01% of the primary beam out of field when the cone was pointed directly towards the target and 0.0025% elsewhere (due to scatter within the gantry). No specific 'hot spots' (e.g., insufficient shielding or gaps at abutments) were observed. Focused cone measurements facilitate leakage dose measurements from the linac head directly at the patient plane and allow one to infer the fraction of leakage due to 'direct' photons (along the ray-path from the bremsstrahlung target) and that due to scattered photons.


Assuntos
Aceleradores de Partículas/instrumentação , Segurança do Paciente , Radiometria/instrumentação , Radiometria/métodos , Dosagem Radioterapêutica , Humanos , Modelos Teóricos
5.
Med Phys ; 40(11): 111706, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24320414

RESUMO

PURPOSE: Accurate treatment delivery in high dose rate (HDR) brachytherapy requires correct source dwell positions and dwell times to be administered relative to each other and to the surrounding anatomy. Treatment delivery inaccuracies predominantly occur for two reasons: (i) anatomical movement or (ii) as a result of human errors that are usually related to incorrect implementation of the planned treatment. Electronic portal imaging devices (EPIDs) were originally developed for patient position verification in external beam radiotherapy and their application has been extended to provide dosimetric information. The authors have characterized the response of an EPID for use with an (192)Ir brachytherapy source to demonstrate its use as a verification device, providing both source position and dosimetric information. METHODS: Characterization of the EPID response using an (192)Ir brachytherapy source included investigations of reproducibility, linearity with dose rate, photon energy dependence, and charge build-up effects associated with exposure time and image acquisition time. Source position resolution in three dimensions was determined. To illustrate treatment verification, a simple treatment plan was delivered to a phantom and the measured EPID dose distribution compared with the planned dose. RESULTS: The mean absolute source position error in the plane parallel to the EPID, for dwells measured at 50, 100, and 150 mm source to detector distances (SDD), was determined to be 0.26 mm. The resolution of the z coordinate (perpendicular distance from detector plane) is SDD dependent with 95% confidence intervals of ± 0.1, ± 0.5, and ± 2.0 mm at SDDs of 50, 100, and 150 mm, respectively. The response of the EPID is highly linear to dose rate. The EPID exhibits an over-response to low energy incident photons and this nonlinearity is incorporated into the dose calibration procedure. A distance (spectral) dependent dose rate calibration procedure has been developed. The difference between measured and planned dose is less than 2% for 98.0% of pixels in a two-dimensional plane at an SDD of 100 mm. CONCLUSIONS: Our application of EPID dosimetry to HDR brachytherapy provides a quality assurance measure of the geometrical distribution of the delivered dose as well as the source positions, which is not possible with any current HDR brachytherapy verification system.


Assuntos
Braquiterapia/métodos , Radiometria/métodos , Algoritmos , Calibragem , Catéteres , Desenho de Equipamento , Humanos , Radioisótopos de Irídio/química , Erros Médicos/prevenção & controle , Movimento , Controle de Qualidade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes
6.
Med Phys ; 40(10): 101701, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24089891

RESUMO

PURPOSE: Deformable image registration (DIR) has become a key tool for adaptive radiotherapy to account for inter- and intrafraction organ deformation. Of contemporary interest, the application to deformable dose accumulation requires accurate deformation even in low contrast regions where dose gradients may exist within near-uniform tissues. One expects high-contrast features to generally be deformed more accurately by DIR algorithms. The authors systematically assess the accuracy of 12 DIR algorithms and quantitatively examine, in particular, low-contrast regions, where accuracy has not previously been established. METHODS: This work investigates DIR algorithms in three dimensions using deformable gel (DEFGEL) [U. J. Yeo, M. L. Taylor, L. Dunn, R. L. Smith, T. Kron, and R. D. Franich, "A novel methodology for 3D deformable dosimetry," Med. Phys. 39, 2203-2213 (2012)], for application to mass- and density-conserving deformations. CT images of DEFGEL phantoms with 16 fiducial markers (FMs) implanted were acquired in deformed and undeformed states for three different representative deformation geometries. Nonrigid image registration was performed using 12 common algorithms in the public domain. The optimum parameter setup was identified for each algorithm and each was tested for deformation accuracy in three scenarios: (I) original images of the DEFGEL with 16 FMs; (II) images with eight of the FMs mathematically erased; and (III) images with all FMs mathematically erased. The deformation vector fields obtained for scenarios II and III were then applied to the original images containing all 16 FMs. The locations of the FMs estimated by the algorithms were compared to actual locations determined by CT imaging. The accuracy of the algorithms was assessed by evaluation of three-dimensional vectors between true marker locations and predicted marker locations. RESULTS: The mean magnitude of 16 error vectors per sample ranged from 0.3 to 3.7, 1.0 to 6.3, and 1.3 to 7.5 mm across algorithms for scenarios I to III, respectively. The greatest accuracy was exhibited by the original Horn and Schunck optical flow algorithm. In this case, for scenario III (erased FMs not contributing to driving the DIR calculation), the mean error was half that of the modified demons algorithm (which exhibited the greatest error), across all deformations. Some algorithms failed to reproduce the geometry at all, while others accurately deformed high contrast features but not low-contrast regions-indicating poor interpolation between landmarks. CONCLUSIONS: The accuracy of DIR algorithms was quantitatively evaluated using a tissue equivalent, mass, and density conserving DEFGEL phantom. For the model studied, optical flow algorithms performed better than demons algorithms, with the original Horn and Schunck performing best. The degree of error is influenced more by the magnitude of displacement than the geometric complexity of the deformation. As might be expected, deformation is estimated less accurately for low-contrast regions than for high-contrast features, and the method presented here allows quantitative analysis of the differences. The evaluation of registration accuracy through observation of the same high contrast features that drive the DIR calculation is shown to be circular and hence misleading.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Marcadores Fiduciais , Humanos , Imagens de Fantasmas , Radioterapia Guiada por Imagem
8.
Zootaxa ; 3602: 1-105, 2013 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-24614121

RESUMO

A comprehensive revision of the genus Thouarella is presented. Thirty-five holotypes of the 38 nominal Thouarella species, two varieties, and one form were examined. The number of original Thouarella species has been reduced to 25, mostly through synonymy or new genus combinations. In the process several new species have also been identified, one of which is described here as Thouarella parachilensis nov. sp. The genus is split into two groups based on polyp arrangement: Group 1 with isolated polyps and Group 2 with polyps in pairs or whorls. An illustrated dichotomous key and detailed character table of the 25 Thouarella species are presented alongside an up-to-date account of all species described in the 19th and 20th centuries and summaries of the few described from 2000 onwards. We propose that Thouarella longispinosa is synonymous with Dasystenella acanthina, T. versluysi with T. brucei, and, T. tenuisquamis, T. flabellata, and T. carinata are synonymous with T. laxa. Lastly, we propose that T. bayeri and T. undulata be placed in Plumarella and support recent suggestions that T. alternata, T. recta, T. superba, and T. diadema are also Plumarella.


Assuntos
Antozoários/anatomia & histologia , Antozoários/classificação , Animais , Especificidade da Espécie
9.
Med Phys ; 39(9): 5372-83, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22957605

RESUMO

PURPOSE: The use of time-resolved four-dimensional computed tomography (4D-CT) in radiotherapy requires strict quality assurance to ensure the accuracy of motion management protocols. The aim of this work was to design and test a phantom capable of large amplitude motion for use in 4D-CT, with particular interest in small lesions typical for stereotactic body radiotherapy. METHODS: The phantom of "see-saw" design is light weight, capable of including various sample materials and compatible with several surrogate marker signal acquisition systems. It is constructed of polymethylmethacrylate (Perspex) and its movement is controlled via a dc motor and drive wheel. It was tested using two CT scanners with different 4D acquisition methods: the Philips Brilliance Big Bore CT (helical scan, pressure belt) and a General Electric Discovery STE PET∕CT (axial scan, infrared marker). Amplitudes ranging from 1.5 to 6.0 cm and frequencies of up to 40 cycles per minute were used to study the effect of motion on image quality. Maximum intensity projections (MIPs), as well as average intensity projections (AIPs) of moving objects were investigated and their quality dependence on the number of phase reconstruction bins assessed. RESULTS: CT number discrepancies between moving and stationary objects were found to have no systematic dependence on amplitude, frequency, or specific interphase variability. MIP-delineated amplitudes of motion were found to match physical phantom amplitudes to within 2 mm for all motion scenarios tested. Objects undergoing large amplitude motions (>3.0 cm) were shown to cause artefacts in MIP and AIP projections when ten phase bins were assigned. This problem can be mitigated by increasing the number of phase bins in a 4D-CT scan. CONCLUSIONS: The phantom was found to be a suitable tool for evaluating the image quality of 4D-CT motion management technology, as well as providing a quality assurance tool for intercenter∕intervendor testing of commercial 4D-CT systems. When imaging objects with large amplitudes, the completeness criterion described here indicates the number of phase bins required to prevent missing data in MIPs and AIPs. This is most relevant for small lesions undergoing large motions.


Assuntos
Tomografia Computadorizada Quadridimensional/instrumentação , Neoplasias/diagnóstico por imagem , Neoplasias/cirurgia , Imagens de Fantasmas , Radiocirurgia/métodos , Artefatos , Neoplasias/patologia , Carga Tumoral
10.
Med Phys ; 39(9): 5437-45, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22957611

RESUMO

PURPOSE: There are a range of genetic and nongenetic factors influencing the elemental composition of different human tissues. The elemental composition of cancerous tissues frequently differs from healthy tissue of the same organ, particularly in high-Z trace element concentrations. For this reason, one could suggest that this may be exploited in diagnostics and perhaps even influence dosimetry. METHODS: In this work, for the first time, effective atomic numbers are computed for common cancerous and healthy tissues using a robust, energy-dependent approach between 10 keV and 100 MeV. These are then quantitatively compared within the context of diagnostics and dosimetry. RESULTS: Differences between effective atomic numbers of healthy and diseased tissues are found to be typically less than 10%. Fibrotic tissues and calcifications of the breast exhibit substantial (tens to hundreds of percent) differences to healthy tissue. Expectedly, differences are most pronounced in the photoelectric regime and consequently most relevant for kV imaging∕therapy and radionuclides with prominent low-energy peaks. Cancerous tissue of the testes and stomach have lower effective atomic numbers than corresponding healthy tissues, while diseased tissues of the other organ sites typically have higher values. CONCLUSIONS: As dose calculation approaches improve in accuracy, there may be an argument for the explicit inclusion of pathologies. This is more the case for breast, penile, prostate, nasopharyngeal, and stomach cancer, less so for testicular and kidney cancer. The calculated data suggest dual-energy computed tomography could potentially improve lesion identification in the aforementioned organs (with the exception of testicular cancer), with most import in breast imaging. Ultimately, however, the differences are very small. It is likely that the assumption of a generic "tissue ramp" in planning will be sufficient for the foreseeable future, and that the Z differences do not notably aid lesion detection beyond that already facilitated by differences in mass density.


Assuntos
Neoplasias da Mama/química , Neoplasias da Mama/diagnóstico , Mama/química , Mama/citologia , Mama/patologia , Neoplasias da Mama/patologia , Humanos , Método de Monte Carlo , Radiometria
11.
Med Phys ; 39(8): 5065-72, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22894432

RESUMO

PURPOSE: Strategies for dose accumulation in deforming anatomy are of interest in radiotherapy. Algorithms exist for the deformation of dose based on patient image sets, though these are sometimes contentious because not all such image calculations are constrained by physical laws. While tumor and organ motion has been a key area of study for a considerable amount of time, deformation is of increasing interest. In this work, we demonstrate a full 3D experimental validation of results from a range of dose deformation algorithms available in the public domain. METHODS: We recently developed the first tissue-equivalent, full 3D deformable dosimetric phantom-"DEFGEL." To assess the accuracy of dose-warping based on deformable image registration (DIR), we have measured doses in undeformed and deformed states of the DEFGEL dosimeter and compared these to planned doses and warped doses. In this way we have directly evaluated the accuracy of dose-warping calculations for 11 different algorithms. We have done this for a range of stereotactic irradiation schemes and types and magnitudes of deformation. RESULTS: The original Horn and Schunck algorithm is shown to be the best performing of the 11 algorithms trialled. Comparing measured and dose-warped calculations for this method, it is found that for a 10 × 10 mm(2) square field, γ(3%∕3mm) = 99.9%; for a 20 × 20 mm(2) cross-shaped field, γ(3%∕3mm) = 99.1%; and for a multiple dynamic arc (0.413 cm(3) PTV) treatment adapted from a patient treatment plan, γ(3%∕3mm) = 95%. In each case, the agreement is comparable to-but consistently ∼1% less than-comparison between measured and calculated (planned) dose distributions in the absence of deformation. The magnitude of the deformation, as measured by the largest displacement experienced by any voxel in the volume, has the greatest influence on the accuracy of the warped dose distribution. Considering the square field case, the smallest deformation (∼9 mm) yields agreement of γ(3%∕3mm) = 99.9%, while the most significant deformation (∼20 mm) yields agreement of γ(3%∕3mm) = 96.7%. CONCLUSIONS: We have confirmed that, for a range of mass and density conserving deformations representative of those observable in anatomical targets, DIR-based dose-warping can yield accurate predictions of the dose distribution. Substantial differences can be seen between the results of different algorithms indicating that DIR performance should be scrutinized before application todose-warping. We have demonstrated that the DEFGEL deformable dosimeter can be used to evaluate DIR performance and the accuracy of dose-warping results by direct measurement.


Assuntos
Imageamento Tridimensional/métodos , Radiometria/métodos , Algoritmos , Elétrons , Géis/química , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Fótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Reprodutibilidade dos Testes
12.
Phys Med Biol ; 57(11): 3359-69, 2012 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-22572565

RESUMO

The quality assurance of stereotactic radiotherapy and radiosurgery treatments requires the use of small-field dose measurements that can be experimentally challenging. This study used Monte Carlo simulations to establish that PAGAT dosimetry gel can be used to provide accurate, high-resolution, three-dimensional dose measurements of stereotactic radiotherapy fields. A small cylindrical container (4 cm height, 4.2 cm diameter) was filled with PAGAT gel, placed in the parietal region inside a CIRS head phantom and irradiated with a 12-field stereotactic radiotherapy plan. The resulting three-dimensional dose measurement was read out using an optical CT scanner and compared with the treatment planning prediction of the dose delivered to the gel during the treatment. A BEAMnrc/DOSXYZnrc simulation of this treatment was completed, to provide a standard against which the accuracy of the gel measurement could be gauged. The three-dimensional dose distributions obtained from Monte Carlo and from the gel measurement were found to be in better agreement with each other than with the dose distribution provided by the treatment planning system's pencil beam calculation. Both sets of data showed close agreement with the treatment planning system's dose distribution through the centre of the irradiated volume and substantial disagreement with the treatment planning system at the penumbrae. The Monte Carlo calculations and gel measurements both indicated that the treated volume was up to 3 mm narrower, with steeper penumbrae and more variable out-of-field dose, than predicted by the treatment planning system. The Monte Carlo simulations allowed the accuracy of the PAGAT gel dosimeter to be verified in this case, allowing PAGAT gel to be utilized in the measurement of dose from stereotactic and other radiotherapy treatments, with greater confidence in the future.


Assuntos
Método de Monte Carlo , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Cabeça/diagnóstico por imagem , Cabeça/efeitos da radiação , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
13.
Med Phys ; 39(4): 2203-13, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22482642

RESUMO

PURPOSE: Interfraction and intrafraction variation in anatomic structures is a significant challenge in contemporary radiotherapy. The objective of this work is to develop a novel tool for deformable structure dosimetry, using a tissue-equivalent deformable gel dosimeter that can reproducibly simulate targets subject to deformation. This will enable direct measurement of integrated doses delivered in different deformation states, and the verification of dose deforming algorithms. METHODS: A modified version of the nPAG polymer gel has been used as a deformable 3D dosimeter and phantom to investigate doses delivered to deforming tissue-equivalent geometry. The deformable gel (DEFGEL) dosimeter/phantom is comprised of polymer gel in a latex membrane, moulded (in this case) into a cylindrical geometry, and deformed with an acrylic compressor. Fifteen aluminium fiducial markers (FM) were implanted into DEFGEL phantoms and the reproducibility of deformation was determined via multiple computed tomography (CT) scans in deformed and nondeformed states before and after multiple (up to 150) deformations. Dose was delivered to the DEFGEL phantom in three arrangements: (i) without deformation, (ii) with deformation, and (iii) cumulative exposures with and without deformation, i.e., dose integration. Irradiations included both square field and a stereotactic multiple dynamic arc treatment adapted from a patient plan. Doses delivered to the DEFGEL phantom were read out using cone beam optical CT. RESULTS: Reproducibility was verified by observation of interscan shifts of FM locations (as determined via CT), measured from an absolute reference point and in terms of inter-FM distance. The majority (76%) of points exhibited zero shift, with others shifting by one pixel size consistent with setup error as confirmed with a control sample. Comparison of dose profiles and 2D isodose distributions from the three arrangements illustrated complex spatial redistribution of dose in all three dimensions occurring as a result of the change in shape of the target between irradiations, even for a relatively simple deformation. Discrepancies of up to 30% of the maximum dose were evident from dose difference maps for three orthogonal planes taken through the isocenter of a stereotactic field. CONCLUSIONS: This paper describes the first use of a tissue-equivalent, 3D dose-integrating deformable phantom that yields integrated or redistributed dosimetric information. The proposed methodology readily yields three-dimensional (3D) dosimetric data from radiation delivery to the DEFGEL phantom in deformed and undeformed states. The impacts of deformation on dose distributions were readily seen in the isodose contours and line profiles from the three arrangements. It is demonstrated that the system is potentially capable of reproducibly emulating the physical deformation of an organ, and therefore can be used to evaluate absorbed doses to deformable targets and organs at risk in three dimensions and to validate deformation algorithms applied to dose distributions.


Assuntos
Géis/química , Géis/efeitos da radiação , Radiometria/instrumentação , Tomografia Computadorizada por Raios X/métodos , Módulo de Elasticidade , Teste de Materiais , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Radiat Prot Dosimetry ; 152(4): 304-12, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22511732

RESUMO

Out-of-field doses to untargeted organs may have long-term detrimental health effects for patients treated with radiotherapy. It has been observed that equivalent treatments delivered to patients with different accelerators may result in significant differences in the out-of-field dose. In this work, the points of leakage dose are identified about the gantry of several treatment units. The origin of the observed higher doses is investigated. LiF:Mg,Cu,P thermoluminescent dosimetry has been employed to quantify the dose at a several points around the linac head of various linear accelerators (linacs): a Varian 600C, Varian 21-iX, Siemens Primus and Elekta Synergy-II. Comparisons are also made between different energy modes, collimator rotations and field sizes. Significant differences in leaked photon doses were identified when comparing the various linac models. The isocentric-waveguide 600C generally exhibits the lowest leakage directed towards the patient. The Siemens and Elekta models generally produce a greater leakage than the Varian models. The leakage 'hotspots' are evident on the gantry section housing the waveguide on the 21-iX. For all machines, there are significant differences in the x and y directions. Larger field sizes result in a greater leakage at the interface plate. There is a greater leakage around the waveguide when operating in a low-energy mode, but a greater leakage for the high-energy mode at the linac face. Of the vendors investigated, the Varian 600C showed the lowest average leakage dose. The Varian 21-iX showed double the dose of the 600C. The Elekta Synergy-II had on average four times the dose leakage than the 600C, and the Siemens Primus showed an average of five times that of the 600C. All vendors show strong differences in the x and y directions. The results offer the potential for patient-positioning strategies, linac choice and shielding strategies to reduce the leakage dose to patients.


Assuntos
Modelos Teóricos , Aceleradores de Partículas/instrumentação , Proteção Radiológica/métodos , Radioterapia de Alta Energia/instrumentação , Dosimetria Termoluminescente/métodos , Transdutores , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador , Espalhamento de Radiação
15.
Australas Phys Eng Sci Med ; 35(1): 93-100, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22119931

RESUMO

A commercially available motion phantom (QUASAR, Modus Medical) was modified for programmable motion control with the aim of reproducing patient respiratory motion in one dimension in both the anterior-posterior and superior-inferior directions, as well as, providing controllable breath-hold and sinusoidal patterns for the testing of radiotherapy gating systems. In order to simulate realistic patient motion, the DC motor was replaced by a stepper motor. A separate 'chest-wall' motion platform was also designed to accommodate a variety of surrogate marker systems. The platform employs a second stepper motor that allows for the decoupling of the chest-wall and insert motion. The platform's accuracy was tested by replicating patient traces recorded with the Varian real-time position management (RPM) system and comparing the motion platform's recorded motion trace with the original patient data. Six lung cancer patient traces recorded with the RPM system were uploaded to the motion platform's in-house control software and subsequently replicated through the phantom motion platform. The phantom's motion profile was recorded with the RPM system and compared to the original patient data. Sinusoidal and breath-hold patterns were simulated with the motion platform and recorded with the RPM system to verify the systems potential for routine quality assurance of commercial radiotherapy gating systems. There was good correlation between replicated and actual patient data (P 0.003). Mean differences between the location of maxima in replicated and patient data-sets for six patients amounted to 0.034 cm with the corresponding minima mean equal to 0.010 cm. The upgraded motion phantom was found to replicate patient motion accurately as well as provide useful test patterns to aid in the quality assurance of motion management methods and technologies.


Assuntos
Neoplasias/radioterapia , Imagens de Fantasmas , Técnicas de Imagem de Sincronização Respiratória/métodos , Algoritmos , Simulação por Computador , Humanos , Movimento (Física) , Planejamento da Radioterapia Assistida por Computador , Software
16.
Phys Med Biol ; 55(17): N451-63, 2010 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-20702922

RESUMO

This work is focussed on developing a commissioning procedure so that a Monte Carlo model, which uses BEAMnrc's standard VARMLC component module, can be adapted to match a specific BrainLAB m3 micro-multileaf collimator (microMLC). A set of measurements are recommended, for use as a reference against which the model can be tested and optimized. These include radiochromic film measurements of dose from small and offset fields, as well as measurements of microMLC transmission and interleaf leakage. Simulations and measurements to obtain microMLC scatter factors are shown to be insensitive to relevant model parameters and are therefore not recommended, unless the output of the linear accelerator model is in doubt. Ultimately, this note provides detailed instructions for those intending to optimize a VARMLC model to match the dose delivered by their local BrainLAB m3 microMLC device.


Assuntos
Neoplasias Encefálicas/radioterapia , Dosimetria Fotográfica/métodos , Método de Monte Carlo , Radiocirurgia/métodos , Radioterapia Conformacional/métodos , Simulação por Computador , Dosimetria Fotográfica/instrumentação , Humanos , Modelos Lineares , Modelos Biológicos , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Radioterapia Conformacional/instrumentação
17.
Phys Med Biol ; 55(3): 873-81, 2010 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-20071767

RESUMO

Despite the highly localized doses that may be delivered via stereotactic radiotherapy, a small dose is nonetheless delivered to out-of-field regions, which may cause detriment to the patient. In this work, a systematic set of dose measurements have been undertaken up to a distance of 45 cm from the isocentre, for stereotactic fields shaped by a BrainLAB mini-multileaf collimator (MMLC) mounted on a Varian 600C linear accelerator. A range of treatment parameters were varied so as to determine the factors of greatest influence and establish relationships with dose. The commercial treatment planning software (TPS) miscalculates the dose to out-of-field regions. Measured dose decreases consistently out to 45 cm, whereas the TPS decreases out to 10-15 cm, at which point the predicted dose is constant. At the 5-10 cm off-axis distance (OAD), measurements indicate doses of about 5-10% of the dose at the isocentre, 1% at 15 cm OAD and 0.1% at 45 cm OAD. There are several observed trends. Greater MMLC field sizes (with static jaw) result in higher out-of-field dose, as do shallower depths. The source-to-surface distance does not greatly influence peripheral dose. However, the results given in this work do indicate that simple treatment arrangements, such as preferable collimator rotation, would in certain cases reduce out-of-field dose by an order of magnitude. Peripheral dose raises questions of treatment optimization, particularly in cases where patients have a long life expectancy in which secondary effects may become manifest, such as in the treatment of paediatric patients or those with a non-malignant primary. For instance, for a 20 Gy hypo-fractionated treatment, dose to out-of-field regions is of the order of cGy-a substantial dose in radiation protection terms.


Assuntos
Radiometria/métodos , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/instrumentação , Software , Água
18.
Mycopathologia ; 168(2): 95-100, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19360479

RESUMO

A second case of histoplasmosis in a captive mara (Dolichotis patagonum) from a colony at the wildlife park Africam Safari, Puebla, Mexico, is described, and the mara died with disseminated clinical form of the disease, affecting mostly the large intestine and adrenal. The pathological findings of this case 2 revealed severe granulomatous typhlocolitis and moderate granulomatous gastrohepatic lymphadenitis with numerous yeast-like cells, 2-4 mum in diameter, with a clear halo surrounding them inside the cytoplasm of macrophages, suggesting the parasitic form of Histoplasma capsulatum. Adrenocortical cells had abundant similar microorganisms in their cytoplasm without any associated lesion. Gomori's methenamine silver and periodic acid Schiff stained positively these microorganisms. Immunohistochemistry, using a rabbit anti-H. capsulatum serum, and transmission electron microscopy supported the diagnosis of H. capsulatum infection.


Assuntos
Histoplasma/isolamento & purificação , Histoplasmose/veterinária , Roedores/parasitologia , Glândulas Suprarrenais/parasitologia , Glândulas Suprarrenais/patologia , Animais , Citoplasma/parasitologia , Histocitoquímica/métodos , Histoplasmose/patologia , Imuno-Histoquímica/métodos , Intestino Grosso/patologia , Linfonodos/parasitologia , Linfonodos/patologia , Macrófagos/parasitologia , Masculino , México , Microscopia Eletrônica de Transmissão , Coloração e Rotulagem/métodos
19.
Mem. Inst. Oswaldo Cruz ; 104(1): 112-117, Feb. 2009. mapas, tab
Artigo em Inglês | LILACS | ID: lil-507215

RESUMO

Parasites are increasingly used to complement the evolutionary and ecological adaptation history of their hosts. Pneumocystis pathogenic fungi, which are transmitted from host-to-host via an airborne route, have been shown to constitute genuine host markers of evolution. These parasites can also provide valuable information about their host ecology. Here, we suggest that parasites can be used as phylogeographic markers to understand the geographical distribution of intra-specific host genetic variants. To test our hypothesis, we characterised Pneumocystis isolates from wild bats living in different areas. Bats comprise a wide variety of species; some of them are able to migrate. Thus, bat chorology and migration behaviour can be approached using Pneumocystis as phylogeographic markers. In the present work, we find that the genetic polymorphisms of bat-derived Pneumocystis are structured by host chorology. Therefore, Pneumocystis intra-specific genetic diversity may constitute a useful and relevant phylogeographic tool.


Assuntos
Animais , Quirópteros/microbiologia , Variação Genética , Geografia , Pneumocystis/genética , Argentina , Quirópteros/classificação , França , Guiana Francesa , México , Filogenia , Pneumocystis/classificação , Pneumocystis/isolamento & purificação , Análise de Sequência de DNA , Especificidade da Espécie
20.
Australas Phys Eng Sci Med ; 31(2): 90-109, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18697701

RESUMO

The combination of positron emission tomography (PET) scanners and x-ray computed tomography (CT) scanners into a single PET/CT scanner has resulted in significant improvements in the diagnosis and staging of disease, particularly in the field of oncology. A decade on from the publication of the details of the first PET/CT scanner, we review the technology and applications of the modality. We examine the design aspects of combining two different imaging types into a single scanner, and the artefacts produced such as attenuation correction, motion and CT truncation artefacts. The article also provides a discussion and literature review of the applications of PET/CT to date, covering detection of tumours, radiotherapy treatment planning, patient management, and applications external to the field of oncology.


Assuntos
Neoplasias/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Tomografia por Emissão de Pósitrons/tendências , Técnica de Subtração/tendências , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/tendências , Humanos