Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 178
Filtrar
1.
Radiology ; 312(2): e233038, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39105638

RESUMO

Background Standardized methods to measure and describe Crohn disease strictures at CT enterography are needed to guide clinical decision making and for use in therapeutic studies. Purpose To assess the reliability of CT enterography features to describe Crohn disease strictures and their correlation with stricture severity. Materials and Methods A retrospective study was conducted in 43 adult patients with symptomatic terminal ileal Crohn disease strictures who underwent standard-of-care CT enterography at a tertiary care center at the Cleveland Clinic between January 2008 and August 2016. After training on standardized definitions, four abdominal radiologists blinded to all patient information assessed imaging features (seven continuous measurements and nine observations) of the most distal ileal stricture in two separate sessions (separated by ≥2 weeks) in random order. Features with an interrater intraclass correlation coefficient (ICC) of 0.41 or greater (ie, moderate reliability or better) were considered reliable. Univariable and multivariable linear regression analysis identified reliable features associated with a visual analog scale of overall stricture severity. Significant reliable features were assessed as components of a CT enterography-based model to quantitate stricture severity. Results Examinations in 43 patients (mean age, 52 years ± 16 [SD]; 23 female) were evaluated. Five continuous measurements and six observations demonstrated at least moderate interrater reliability (interrater ICC range, 0.42 [95% CI: 0.25, 0.57] to 0.80 [95% CI: 0.67, 0.88]). Of these, 10 were univariably associated with stricture severity, and three continuous measurements-stricture length (interrater ICC, 0.64 [95% CI: 0.42, 0.81]), maximal associated small bowel dilation (interrater ICC, 0.80 [95% CI: 0.67, 0.88]), and maximal stricture wall thickness (interrater ICC, 0.50 [95% CI: 0.34, 0.62])-were independently associated (P value range, <.001 to .003) with stricture severity in a multivariable model. These three measurements were used to derive a well-calibrated (optimism-adjusted calibration slope = 1.00) quantitative model of stricture severity. Conclusion Standardized CT enterography measurements and observations can reliably describe terminal ileal Crohn disease strictures. Stricture length, maximal associated small bowel dilation, and maximal stricture wall thickness are correlated with stricture severity. © RSNA, 2024 Supplemental material is available for this article. See also the article by Rieder et al in this issue. See also the editorial by Galgano and Summerlin in this issue.


Assuntos
Doença de Crohn , Tomografia Computadorizada por Raios X , Humanos , Doença de Crohn/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Reprodutibilidade dos Testes , Constrição Patológica/diagnóstico por imagem , Adulto , Idoso
2.
Radiology ; 312(2): e233039, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39105637

RESUMO

Background Clinical decision making and drug development for fibrostenosing Crohn disease is constrained by a lack of imaging definitions, scoring conventions, and validated end points. Purpose To assess the reliability of MR enterography features to describe Crohn disease strictures and determine correlation with stricture severity. Materials and Methods A retrospective study of patients with symptomatic terminal ileal Crohn disease strictures who underwent MR enterography at tertiary care centers (Cleveland Clinic: September 2013 to November 2020; Mayo Clinic: February 2008 to March 2019) was conducted by using convenience sampling. In the development phase, blinded and trained radiologists independently evaluated 26 MR enterography features from baseline and follow-up examinations performed more than 6 months apart, with no bowel resection performed between examinations. Follow-up examinations closest to 12 months after baseline were selected. Reliability was assessed using the intraclass correlation coefficient (ICC). In the validation phase, after five features were redefined, reliability was re-estimated in an independent convenience sample using baseline examinations. Multivariable linear regression analysis identified features with at least moderate interrater reliability (ICC ≥0.41) that were independently associated with stricture severity. Results Ninety-nine (mean age, 40 years ± 14 [SD]; 50 male) patients were included in the development group and 51 (mean age, 45 years ± 16 [SD]; 35 female) patients were included in the validation group. In the development group, nine features had at least moderate interrater reliability. One additional feature demonstrated moderate reliability in the validation group. Stricture length (ICC = 0.85 [95% CI: 0.75, 0.91] and 0.91 [95% CI: 0.75, 0.96] in development and validation phase, respectively) and maximal associated small bowel dilation (ICC = 0.74 [95% CI: 0.63, 0.80] and 0.73 [95% CI: 0.58, 0.87] in development and validation group, respectively) had the highest interrater reliability. Stricture length, maximal stricture wall thickness, and maximal associated small bowel dilation were independently (regression coefficients, 0.09-3.97; P < .001) associated with stricture severity. Conclusion MR enterography definitions and scoring conventions for reliably assessing features of Crohn disease strictures were developed and validated, and feature correlation with stricture severity was determined. © RSNA, 2024 Supplemental material is available for this article. See also the article by Rieder and Ma et al in this issue. See also the editorial by Galgano and Summerlin in this issue.


Assuntos
Doença de Crohn , Imageamento por Ressonância Magnética , Humanos , Doença de Crohn/diagnóstico por imagem , Feminino , Masculino , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Adulto , Reprodutibilidade dos Testes , Constrição Patológica/diagnóstico por imagem , Pessoa de Meia-Idade
3.
Nat Rev Gastroenterol Hepatol ; 21(8): 572-584, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38831007

RESUMO

Fibrostenosis of the small bowel is common in patients with Crohn's disease. No consensus recommendations on definition, diagnosis and management in clinical practice are currently available. In this Consensus Statement, we present a clinical practice RAND/UCLA appropriateness study on the definition, diagnosis and clinical management of fibrostenosing Crohn's disease. It was conducted by a panel of 28 global experts and one patient representative. Following a systematic literature review, 526 candidate items grouped into 136 questions were generated and subsequently evaluated for appropriateness. Strictures are best defined as wall thickening, luminal narrowing and prestenotic dilation. Cross-sectional imaging is required for accurate diagnosis of fibrostenosing Crohn's disease, and it is recommended before making treatment decisions. It should also assess the degree of inflammation in the bowel wall. Multiple options for medical anti-inflammatory, endoscopic and surgical therapies were suggested, including follow-up strategies following therapy. This Consensus Statement supports clinical practice through providing guidance on definitions, diagnosis and therapeutic management of patients with fibrostenosing small bowel Crohn's disease.


Assuntos
Consenso , Doença de Crohn , Intestino Delgado , Doença de Crohn/diagnóstico , Doença de Crohn/terapia , Humanos , Intestino Delgado/patologia , Fibrose
4.
Eur Radiol ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38836939

RESUMO

OBJECTIVE: Improving prognostication to direct personalised therapy remains an unmet need. This study prospectively investigated promising CT, genetic, and immunohistochemical markers to improve the prediction of colorectal cancer recurrence. MATERIAL AND METHODS: This multicentre trial (ISRCTN 95037515) recruited patients with primary colorectal cancer undergoing CT staging from 13 hospitals. Follow-up identified cancer recurrence and death. A baseline model for cancer recurrence at 3 years was developed from pre-specified clinicopathological variables (age, sex, tumour-node stage, tumour size, location, extramural venous invasion, and treatment). Then, CT perfusion (blood flow, blood volume, transit time and permeability), genetic (RAS, RAF, and DNA mismatch repair), and immunohistochemical markers of angiogenesis and hypoxia (CD105, vascular endothelial growth factor, glucose transporter protein, and hypoxia-inducible factor) were added to assess whether prediction improved over tumour-node staging alone as the main outcome measure. RESULTS: Three hundred twenty-six of 448 participants formed the final cohort (226 male; mean 66 ± 10 years. 227 (70%) had ≥ T3 stage cancers; 151 (46%) were node-positive; 81 (25%) developed subsequent recurrence. The sensitivity and specificity of staging alone for recurrence were 0.56 [95% CI: 0.44, 0.67] and 0.58 [0.51, 0.64], respectively. The baseline clinicopathologic model improved specificity (0.74 [0.68, 0.79], with equivalent sensitivity of 0.57 [0.45, 0.68] for high vs medium/low-risk participants. The addition of prespecified CT perfusion, genetic, and immunohistochemical markers did not improve prediction over and above the clinicopathologic model (sensitivity, 0.58-0.68; specificity, 0.75-0.76). CONCLUSION: A multivariable clinicopathological model outperformed staging in identifying patients at high risk of recurrence. Promising CT, genetic, and immunohistochemical markers investigated did not further improve prognostication in rigorous prospective evaluation. CLINICAL RELEVANCE STATEMENT: A prognostic model based on clinicopathological variables including age, sex, tumour-node stage, size, location, and extramural venous invasion better identifies colorectal cancer patients at high risk of recurrence for neoadjuvant/adjuvant therapy than stage alone. KEY POINTS: Identification of colorectal cancer patients at high risk of recurrence is an unmet need for treatment personalisation. This model for recurrence, incorporating many patient variables, had higher specificity than staging alone. Continued optimisation of risk stratification schema will help individualise treatment plans and follow-up schedules.

5.
Eur J Radiol ; 175: 111454, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38598964

RESUMO

OBJECTIVES: To evaluate the additional diagnostic benefit of diffusion weighted imaging (DWI) and contrast enhanced (CE) images during MR enterography (MRE) of Crohn's disease. METHODS: Datasets from 73 patients (mean age 32; 40 male) (28 new-diagnosis, 45 relapsed) were read independently by two radiologists selected from a pool of 13. Radiologists interpreted datasets using three sequential sequence blocks: (1) T2 weighted and steady state free precession gradient echo (SSFP) images alone (T2^); (2) T2 weighted and SSFP images with DWI (T2 + DWI^) and; (3) T2 weighted images, SSFP, DWI and post-contrast enhanced (CE) T1 images (T2 + DWI + CE^), documenting presence, location, and activity of small bowel disease. For each sequence block, sensitivity and specificity (readers combined) was calculated against an outcome-based construct reference standard. RESULTS: 59/73 patients had small bowel disease. Per-patient sensitivity for disease detection was essentially identical (80 % [95 % CI 72, 86], 81 % [73,87], and 79 % [71,86] for T2^, T2 + DWI^and T2 + DWI + CE^respectively). Specificity was identical (82 % [64 to 92]). Per patient sensitivity for disease extent was 56 % (47,65), 56 % (47,65) and 52 % (43 to 61) respectively, and specificity was 82 % (64 to 92) for all blocks. Sensitivity for active disease was 97 % (90,99), 97 % (90,99) and 98 % (92,99), and specificity was also comparable between all sequence combination reads. Results were consistent across segments and newly diagnosed/relapse patients. CONCLUSION: There is no additional diagnostic benefit of adding either DWI or CE to T2 FSE and SSFP sequences for evaluating small bowel Crohn's disease, suggesting MRE protocols can be simplified safely.


Assuntos
Meios de Contraste , Doença de Crohn , Imagem de Difusão por Ressonância Magnética , Sensibilidade e Especificidade , Humanos , Doença de Crohn/diagnóstico por imagem , Masculino , Feminino , Adulto , Imagem de Difusão por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adolescente , Idoso , Adulto Jovem , Aumento da Imagem/métodos
6.
Aliment Pharmacol Ther ; 59(8): 928-940, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38436124

RESUMO

BACKGROUND: Stricturing Crohn's disease (CD) occurs most commonly in the terminal ileum and poses a clinical problem. Cross-sectional imaging modalities such as intestinal ultrasound (IUS), computed tomography enterography (CTE), and magnetic resonance enterography (MRE) allow for assessment of the entire bowel wall and associated peri-enteric findings. Radiologic definitions of strictures have been developed for CTE and MRE; their reliability and responsiveness are being evaluated in index development programs. A comprehensive assessment strategy for strictures using IUS is needed. AIMS: To provide a detailed summary of definitions, diagnosis and monitoring of strictures on IUS as well as technical aspects of image acquisition. METHODS: We searched four databases up to 6 January 2024. Two-stage screening was done in duplicate. We assessed risk of bias using QUADAS-2. RESULTS: There were 56 studies eligible for inclusion. Definitions for strictures on IUS are heterogeneous, but the overall accuracy for diagnosis of strictures is high. The capability of IUS for characterising inflammation versus fibrosis in strictures is not accurate enough to be used in clinical practice or trials. We summarise definitions for improvement of strictures on IUS, and discuss parameters for image acquisition and standardisation. CONCLUSIONS: This systematic review is the first step for a structured program to develop a stricture IUS index for CD.


Assuntos
Doença de Crohn , Obstrução Intestinal , Humanos , Doença de Crohn/diagnóstico , Doença de Crohn/diagnóstico por imagem , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/patologia , Reprodutibilidade dos Testes , Intestinos/patologia , Imageamento por Ressonância Magnética/métodos
8.
Eur Radiol ; 34(1): 455-464, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37526665

RESUMO

OBJECTIVES: The simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) are promising intestinal ultrasound (IUS) indices of CD, but studied mainly in small settings with few sonographers. We compared SUS-CD and BUSS against histological and magnetic resonance enterography (MRE) reference standards in a post hoc analysis of a prospective multicentre, multireader trial. METHODS: Participants recruited to the METRIC trial (ISRCTN03982913) were studied, including those with available terminal ileal (TI) biopsies. Sensitivity and specificity of SUS-CD and BUSS for TI CD activity were calculated with 95% confidence intervals (CI), from the prospective observations of the original METRIC trial sonographers against the histological activity index (HAI) and the simplified magnetic resonance index of activity (sMARIA). RESULTS: We included 284 patients (median 31.5 years, IQR 23-46) from 8 centres, who underwent IUS and MRE. Of these, 111 patients had available terminal ileal biopsies with HAI scoring. Against histology, sensitivity and specificity for active disease were 79% (95% CI 69-86%) and 50% (31-69%) for SUS-CD, and 66% (56-75%) and 68% (47-84%) for BUSS, respectively. Compared to sMARIA, the sensitivity and specificity for active CD were 81% (74-86%) and 75% (66-83%) for SUS-CD, and 68% (61-74%) and 85% (76-91%) for BUSS, respectively. The sensitivity of SUS-CD was significantly greater than that of BUSS against HAI and sMARIA (p < 0.001), but its specificity was significantly lower than of BUSS against the MRE reference standard (p = 0.003). CONCLUSIONS: Particularly when compared to MRE activity scoring, SUS-CD and BUSS are promising tools in a real-world clinical setting. CLINICAL RELEVANCE STATEMENT: When tested using data from a multicentre, multireader diagnostic accuracy trial, the simple ultrasound activity score for Crohn's disease (SUS-CD) and bowel ultrasound score (BUSS) were clinically viable intestinal ultrasound indices that were reasonably sensitive and specific for terminal ileal Crohn's disease, especially when compared to a magnetic resonance reference standard. KEY POINTS: The simple ultrasound activity score for Crohn's disease and bowel ultrasound score are promising intestinal ultrasound indices of Crohn's disease but to date studied mainly in small settings with few sonographers. Compared to histology and the magnetic resonance reference standard in a multicentre, multireader setting, the sensitivity of simple ultrasound activity score for Crohn's disease is significantly greater than that of bowel ultrasound score. The specificity of simple ultrasound activity score for Crohn's disease was significantly lower than that of bowel ultrasound score compared to the magnetic resonance enterography reference standard. The specificity of both indices was numerically higher when the magnetic resonance enterography reference standard was adopted.


Assuntos
Doença de Crohn , Adulto , Humanos , Doença de Crohn/patologia , Íleo/diagnóstico por imagem , Íleo/patologia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estudos Prospectivos
9.
Inflamm Bowel Dis ; 30(3): 357-369, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37524088

RESUMO

BACKGROUND: Perianal fistulas and abscesses occur commonly as complications of pediatric Crohn's disease (CD). A validated imaging assessment tool for quantification of perianal disease severity and activity is needed to evaluate treatment response. We aimed to identify magnetic resonance imaging (MRI)-based measures of perianal fistulizing disease activity and study design features appropriate for pediatric patients. METHODS: Seventy-nine statements relevant to MRI-based assessment of pediatric perianal fistulizing CD activity and clinical trial design were generated from literature review and expert opinion. Statement appropriateness was rated by a panel (N = 15) of gastroenterologists, radiologists, and surgeons using modified RAND/University of California Los Angeles appropriateness methodology. RESULTS: The modified Van Assche Index (mVAI) and the Magnetic Resonance Novel Index for Fistula Imaging in CD (MAGNIFI-CD) were considered appropriate instruments for use in pediatric perianal fistulizing disease clinical trials. Although there was concern regarding the use of intravascular contrast material in pediatric patients, its use in clinical trials was considered appropriate. A clinically evident fistula tract and radiologic disease defined as at least 1 fistula or abscess on pelvic MRI were considered appropriate trial inclusion criteria. A coprimary clinical and radiologic end point and inclusion of a patient-reported outcome were also considered appropriate. CONCLUSION: Outcomes of treatment of perianal fistulizing disease in children must include MRI. Existing multi-item measures, specifically the mVAI and MAGNIFI-CD, can be adapted and used for children. Further research to assess the operating properties of the indices when used in a pediatric patient population is ongoing.


Assuntos
Doença de Crohn , Fístula , Criança , Humanos , Abscesso , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ensaios Clínicos como Assunto
10.
Eur Radiol ; 34(3): 1746-1754, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37646807

RESUMO

OBJECTIVES: To explore the potential impact of a dedicated virtual training course on MRI staging confidence and performance in rectal cancer. METHODS: Forty-two radiologists completed a stepwise virtual training course on rectal cancer MRI staging composed of a pre-course (baseline) test with 7 test cases (5 staging, 2 restaging), a 1-day online workshop, 1 month of individual case readings (n = 70 cases with online feedback), a live online feedback session supervised by two expert faculty members, and a post-course test. The ESGAR structured reporting templates for (re)staging were used throughout the course. Results of the pre-course and post-course test were compared in terms of group interobserver agreement (Krippendorf's alpha), staging confidence (perceived staging difficulty), and diagnostic accuracy (using an expert reference standard). RESULTS: Though results were largely not statistically significant, the majority of staging variables showed a mild increase in diagnostic accuracy after the course, ranging between + 2% and + 17%. A similar trend was observed for IOA which improved for nearly all variables when comparing the pre- and post-course. There was a significant decrease in the perceived difficulty level (p = 0.03), indicating an improved diagnostic confidence after completion of the course. CONCLUSIONS: Though exploratory in nature, our study results suggest that use of a dedicated virtual training course and web platform has potential to enhance staging performance, confidence, and interobserver agreement to assess rectal cancer on MRI virtual training and could thus be a good alternative (or addition) to in-person training. CLINICAL RELEVANCE STATEMENT: Rectal cancer MRI reporting quality is highly dependent on radiologists' expertise, stressing the need for dedicated training/teaching. This study shows promising results for a virtual web-based training program, which could be a good alternative (or addition) to in-person training. KEY POINTS: • Rectal cancer MRI reporting quality is highly dependent on radiologists' expertise, stressing the need for dedicated training and teaching. • Using a dedicated virtual training course and web-based platform, encouraging first results were achieved to improve staging accuracy, diagnostic confidence, and interobserver agreement. • These exploratory results suggest that virtual training could thus be a good alternative (or addition) to in-person training.


Assuntos
Neoplasias Retais , Humanos , Neoplasias Retais/patologia , Imageamento por Ressonância Magnética/métodos , Reto/patologia , Estadiamento de Neoplasias , Mãos
11.
Obes Surg ; 33(12): 3988-3998, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37910328

RESUMO

PURPOSE: Remission of type 2 diabetes (T2D) can be achieved by many, but not all, people following bariatric/metabolic surgery. The mechanisms underlying T2D remission remain incompletely understood. This observational study aimed to identify novel weight-loss independent clinical, metabolic and genetic factors that associate with T2D remission using comprehensive phenotyping. MATERIALS AND METHODS: Ten patients without T2D remission (non-remitters) were matched to 10 patients with T2D remission (remitters) for age, sex, type of surgery, body weight, BMI, post-operative weight loss, duration from surgery and duration of T2D. Detailed body composition assessed using magnetic resonance imaging, gut hormones, serum metabolomics, insulin sensitivity, and genetic risk scores for T2D and anthropometric traits were assessed. RESULTS: Remitters had significantly greater ß-cell function and circulating acyl ghrelin levels, but lower visceral adipose tissue (VAT): subcutaneous adipose tissue (SAT) ratio than non-remitters. Branched-chain amino acids (BCAAs) and VLDL particle size were the most discriminant metabolites between groups. A significant positive correlation between, VAT area, VAT:SAT ratio and circulating levels of BCAAs was observed, whereas a significant negative correlation between BCAAs and ß-cell function was revealed. CONCLUSION: We highlight a potentially novel relationship between VAT and BCAAs, which may play a role in glucoregulatory control. Improvement in ß-cell function, and the role ghrelin plays in its recovery, is likely another key factor influencing T2D remission post-surgery. These findings suggest that adjunctive approaches that target VAT loss and restoration of BCAA metabolism might achieve higher rates of long-term T2D remission post-surgery.


Assuntos
Cirurgia Bariátrica , Diabetes Mellitus Tipo 2 , Obesidade Mórbida , Humanos , Grelina , Obesidade Mórbida/cirurgia , Resultado do Tratamento , Redução de Peso , Biomarcadores
12.
Expert Rev Gastroenterol Hepatol ; 17(11): 1117-1134, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37902040

RESUMO

INTRODUCTION: Cross-sectional imaging techniques including MR and CT enterography and ultrasound are integral to Crohn's disease management, accurate, responsive, and well tolerated. They assess the full thickness of the bowel wall, perienteric environment, and distant complications. As we strive toward tighter disease control, imaging's role will expand further with transmural healing becoming an increasingly important therapeutic target. AREAS COVERED: MEDLINE and Web of Science were searched from 2012 to 2023 inclusive. We review the evidence for cross-sectional imaging in assessing disease activity, phenotyping, and therapeutic response assessment. Emerging novel imaging applications such as quantifying enteric motility and fibrosis, prognostication, and potential utility of artificial intelligence will be covered. Recent international consensus statements highlight the need for standardized imaging reporting and definitions of transmural healing and remission. We will discuss how recent advances may be best integrated into patient care and highlight key outstanding research questions. EXPERT OPINION: Cross-sectional imaging is established in Crohn's disease management. Research emphasis should be placed on optimal integration of imaging modalities in clinical care pathways, workforce training, definitions, and evidence for use of imaging based therapeutic targets such as transmural healing, better phenotyping of stricturing disease, and developing novel techniques, including integration of artificial intelligence.


Assuntos
Doença de Crohn , Doenças Inflamatórias Intestinais , Humanos , Inteligência Artificial , Imageamento por Ressonância Magnética/métodos , Intestino Delgado/diagnóstico por imagem , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/terapia
14.
JACC Cardiovasc Imaging ; 15(12): 2082-2094, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36274040

RESUMO

BACKGROUND: Light chain (AL) and transthyretin (ATTR) amyloid fibrils are deposited in the extracellular space of the myocardium, resulting in heart failure and premature mortality. Extracellular expansion can be quantified by computed tomography, offering a rapid, cheaper, and more practical alternative to cardiac magnetic resonance, especially among patients with cardiac devices or on renal dialysis. OBJECTIVES: This study sought to investigate the association of extracellular volume fraction by computed tomography (ECVCT), myocardial remodeling, and mortality in patients with systemic amyloidosis. METHODS: Patients with confirmed systemic amyloidosis and varying degrees of cardiac involvement underwent electrocardiography-gated cardiac computed tomography. Whole heart and septal ECVCT was analyzed. All patients also underwent clinical assessment, electrocardiography, echocardiography, serum amyloid protein component, and/or technetium-99m (99mTc) 3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy. ECVCT was compared across different extents of cardiac infiltration (ATTR Perugini grade/AL Mayo stage) and evaluated for its association with myocardial remodeling and all-cause mortality. RESULTS: A total of 72 patients were studied (AL: n = 35, ATTR: n = 37; median age: 67 [IQR: 59-76] years, 70.8% male). Mean septal ECVCT was 42.7% ± 13.1% and 55.8% ± 10.9% in AL and ATTR amyloidosis, respectively, and correlated with indexed left ventricular mass (r = 0.426; P < 0.001), left ventricular ejection fraction (r = 0.460; P < 0.001), N-terminal pro-B-type natriuretic peptide (r = 0.563; P < 0.001), and high-sensitivity troponin T (r = 0.546; P < 0.001). ECVCT increased with cardiac amyloid involvement in both AL and ATTR amyloid. Over a mean follow-up of 5.3 ± 2.4 years, 40 deaths occurred (AL: n = 14 [35.0%]; ATTR: n = 26 [65.0%]). Septal ECVCT was independently associated with all-cause mortality in ATTR (not AL) amyloid after adjustment for age and septal wall thickness (HR: 1.046; 95% CI: 1.003-1.090; P = 0.037). CONCLUSIONS: Cardiac amyloid burden quantified by ECVCT is associated with adverse cardiac remodeling as well as all-cause mortality among ATTR amyloid patients. ECVCT may address the need for better identification and risk stratification of amyloid patients, using a widely accessible imaging modality.


Assuntos
Tomografia Computadorizada por Raios X , Função Ventricular Esquerda , Humanos , Masculino , Idoso , Feminino , Volume Sistólico , Valor Preditivo dos Testes , Tomografia
15.
Gut ; 71(12): 2587-2597, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35927032

RESUMO

Endoscopy remains the reference standard for the diagnosis and assessment of patients with inflammatory bowel disease (IBD), but it has several important limitations. Cross-sectional imaging techniques such as magnetic resonance enterography (MRE) and intestinal ultrasound (IUS) are better tolerated and safer. Moreover, they can examine the entire bowel, even in patients with stenoses and/or severe inflammation. A variety of cross-sectional imaging activity scores strongly correlate with endoscopic measures of mucosal inflammation in the colon and terminal ileum. Unlike endoscopy, cross-sectional techniques allow complete visualisation of the small-bowel and assess for extraintestinal disease, which occurs in nearly half of patients with IBD. Extramural findings may predict outcomes better than endoscopic mucosal assessment, so cross-sectional techniques might help identify more relevant therapeutic targets. Coupled with their high sensitivity, these advantages have made MRE and IUS the primary non-invasive options for diagnosing and monitoring Crohn's disease; they are appropriate first-line investigations, and have become viable alternatives to colonoscopy. This review discusses cross-sectional imaging in IBD in current clinical practice as well as research lines that will define the future role of these techniques.


Assuntos
Doença de Crohn , Doenças Inflamatórias Intestinais , Humanos , Doenças Inflamatórias Intestinais/diagnóstico por imagem , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/tratamento farmacológico , Íleo , Colo , Imageamento por Ressonância Magnética/métodos , Inflamação
16.
J Crohns Colitis ; 16(10): 1531-1539, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35481898

RESUMO

BACKGROUND AND AIMS: The simplified magnetic resonance enterography [MRE] index of activity [sMARIA], London, and 'extended' London, scoring systems are widely used in Crohn's disease [CD] to assess disease activity, although validation studies have usually been single-centre, retrospective, and/or used few readers. Here, we evaluated these MRE indices within a prospective, multicentre, multireader, diagnostic accuracy trial. METHODS: A subset of participants [newly diagnosed or suspected of relapse] recruited to the METRIC trial with available terminal ileal [TI] biopsies was included. Using pre-specified thresholds, the sensitivity and specificity of sMARIA, London, and 'extended' London scores for active and severe [sMARIA] TI CD were calculated using different thresholds for the histological activity index [HAI]. RESULTS: We studied 111 patients [median age 29 years, interquartile range 21-41, 75 newly diagnosed, 36 suspected relapse] from seven centres, of whom 22 had no active TI CD [HAI = 0], 39 mild [HAI = 1], 13 moderate [HAI = 2], and 37 severe CD activity [HAI = 3]. In total, 26 radiologists prospectively scored MRE datasets as per their usual clinical practice. Sensitivity and specificity for active disease [HAI >0] were 83% [95% confidence interval 74% to 90%] and 41% [23% to 61%] for sMARIA, 76% [67% to 84%] and 64% [43% to 80%] for the London score, and 81% [72% to 88%] and 41% [23% to 61%] for the 'extended' London score, respectively. The sMARIA had 84% [69-92%] sensitivity and 53% [41-64%] specificity for severe CD. CONCLUSIONS: When tested at their proposed cut-offs in a real-world setting, sMARIA, London, and 'extended' London indices achieve high sensitivity for active TI disease against a histological reference standard, but specificity is low.


Assuntos
Doença de Crohn , Adulto , Humanos , Doença de Crohn/patologia , Estudos Retrospectivos , Estudos Prospectivos , Imageamento por Ressonância Magnética , Recidiva , Padrões de Referência , Espectroscopia de Ressonância Magnética
18.
Eur Radiol ; 32(8): 5075-5085, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35243523

RESUMO

OBJECTIVES: To compare the distention quality and patient experience of oral mannitol and polyethylene glycol (PEG) for MRE. METHODS: This study is a retrospective, observational study of a subset of patients enrolled in a multicentre, prospective trial evaluating the diagnostic accuracy of MRE for small bowel Crohn's. Overall and segmental MRE small bowel distention, from 105 patients (64 F, mean age 37) was scored from 0 = poor to 4 = excellent by two experienced observers (68 [65%] mannitol and 37 [35%] PEG). Additionally, 130 patients (77 F, mean age 34) completed a questionnaire rating tolerability of various symptoms immediately and 2 days after MRE (85 [65%] receiving mannitol 45 [35%] receiving PEG). Distension was compared between agents and between those ingesting ≤ 1 L or > 1 L of mannitol using the test of proportions. Tolerability grades were collapsed into "very tolerable," "moderately tolerable," and "not tolerable." RESULTS: Per patient distension quality was similar between agents ("excellent" or "good" in 54% [37/68] versus 46% [17/37]) with mannitol and PEG respectively. Jejunal distension was significantly better with mannitol compared to PEG (40% [27/68] versus 14% [5/37] rated as excellent or good respectively). There was no significant difference according to the volume of mannitol ingested. Symptom tolerability was comparable between agents, although fullness following MRE was graded as "very tolerable" in 27% (12/45) of patients ingesting PEG, verses 44% (37/84) ingesting mannitol, difference 17% (95% CI 0.6 to 34%). CONCLUSION: Mannitol-based solutions and PEG generally achieve comparable distension quality and side effect profiles, although jejunal distension is better quality with mannitol. Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol. KEY POINTS: • Mannitol-based and PEG-based oral preparation agents generally achieve comparable distension quality for MRE with the exception of the jejunum which is better distended with mannitol. • Mannitol-based and PEG-based oral preparation agents used for MRE have similar side effect profiles. • Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol.


Assuntos
Doença de Crohn , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Adulto , Meios de Contraste/farmacologia , Doença de Crohn/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Manitol/farmacologia , Avaliação de Resultados da Assistência ao Paciente , Polietilenoglicóis , Estudos Prospectivos , Estudos Retrospectivos
19.
Eur Radiol ; 32(7): 4991-5003, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35254485

RESUMO

OBJECTIVES: To identify the main problem areas in the applicability of the current TNM staging system (8th ed.) for the radiological staging and reporting of rectal cancer and provide practice recommendations on how to handle them. METHODS: A global case-based online survey was conducted including 41 image-based rectal cancer cases focusing on various items included in the TNM system. Cases reaching < 80% agreement among survey respondents were identified as problem areas and discussed among an international expert panel, including 5 radiologists, 6 colorectal surgeons, 4 radiation oncologists, and 3 pathologists. RESULTS: Three hundred twenty-one respondents (from 32 countries) completed the survey. Sixteen problem areas were identified, related to cT staging in low-rectal cancers, definitions for cT4b and cM1a disease, definitions for mesorectal fascia (MRF) involvement, evaluation of lymph nodes versus tumor deposits, and staging of lateral lymph nodes. The expert panel recommended strategies on how to handle these, including advice on cT-stage categorization in case of involvement of different layers of the anal canal, specifications on which structures to include in the definition of cT4b disease, how to define MRF involvement by the primary tumor and other tumor-bearing structures, how to differentiate and report lymph nodes and tumor deposits on MRI, and how to anatomically localize and stage lateral lymph nodes. CONCLUSIONS: The recommendations derived from this global survey and expert panel discussion may serve as a practice guide and support tool for radiologists (and other clinicians) involved in the staging of rectal cancer and may contribute to improved consistency in radiological staging and reporting. KEY POINTS: • Via a case-based online survey (incl. 321 respondents from 32 countries), we identified 16 problem areas related to the applicability of the TNM staging system for the radiological staging and reporting of rectal cancer. • A multidisciplinary panel of experts recommended strategies on how to handle these problem areas, including advice on cT-stage categorization in case of involvement of different layers of the anal canal, specifications on which structures to include in the definition of cT4b disease, how to define mesorectal fascia involvement by the primary tumor and other tumor-bearing structures, how to differentiate and report lymph nodes and tumor deposits on MRI, and how to anatomically localize and stage lateral lymph nodes. • These recommendations may serve as a practice guide and support tool for radiologists (and other clinicians) involved in the staging of rectal cancer and may contribute to improved consistency in radiological staging and reporting.


Assuntos
Extensão Extranodal , Neoplasias Retais , Consenso , Humanos , Imageamento por Ressonância Magnética/métodos , Estadiamento de Neoplasias , Neoplasias Retais/patologia , Inquéritos e Questionários
20.
Radiology ; 303(2): 361-370, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35166585

RESUMO

Background Most radiologists reporting CT colonography (CTC) do not undergo compulsory performance accreditation, potentially lowering diagnostic sensitivity. Purpose To determine whether 1-day individualized training in CTC reporting improves diagnostic sensitivity of experienced radiologists for 6-mm or larger lesions, the durability of any improvement, and any associated factors. Materials and Methods This prospective, multicenter cluster-randomized controlled trial was performed in National Health Service hospitals in England and Wales between April 2017 and January 2020. CTC services were cluster randomized into intervention (1-day training plus feedback) or control (no training or feedback) arms. Radiologists in the intervention arm attended a 1-day workshop focusing on CTC reporting pitfalls with individualized feedback. Radiologists in the control group received no training. Sensitivity for 6-mm or larger lesions was tested at baseline and 1, 6, and 12 months thereafter via interpretation of 10 CTC scans at each time point. The primary outcome was the mean difference in per-lesion sensitivity between arms at 1 month, analyzed using multilevel regression after adjustment for baseline sensitivity. Secondary outcomes included per-lesion sensitivity at 6- and 12-month follow-up, sensitivity for flat neoplasia, and effect of prior CTC experience. Results A total of 69 hospitals were randomly assigned to the intervention (31 clusters, 80 radiologists) or control (38 clusters, 59 radiologists) arm. Radiologists were experienced (median, 500-999 CTC scans interpreted) and reported CTC scans routinely (median, 151-200 scans per year). One-month sensitivity improved after intervention (66.4% [659 of 992]) compared with sensitivity in the control group (42.4% [278 of 655]; difference = 20.8%; 95% CI: 14.6, 27.0; P < .001). Improvements were maintained at 6 (66.4% [572 of 861] vs 50.5% [283 of 560]; difference = 13.0%; 95% CI: 7.4, 18.5; P < .001) and 12 (63.7% [310 of 487] vs 44.4% [187 of 421]; difference = 16.7%; 95% CI: 10.3, 23.1; P < .001) months. This beneficial effect applied to flat lesions (difference = 22.7%; 95% CI: 15.5, 29.9; P < .001) and was independent of career experience (≥1500 CTC scans: odds ratio = 1.09; 95% CI: 0.88, 1.36; P = .22). Conclusion For radiologists evaluating CT colonography studies, a 1-day training intervention yielded sustained improvement in detection of clinically relevant colorectal neoplasia, independent of previous career experience. Clinical trial registration no. NCT02892721 © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Pickhardt in this issue. An earlier incorrect version appeared online and in print. This article was corrected on February 28, 2022.


Assuntos
Colonografia Tomográfica Computadorizada , Neoplasias Colorretais , Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Detecção Precoce de Câncer , Humanos , Estudos Prospectivos , Medicina Estatal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA