Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39361224

RESUMO

BACKGROUND: While the effect of pre-transplant weight on patient outcomes following heart transplantation (HTx) has previously been studied, data regarding the impact of dynamic weight change prior to HTx are extremely limited. OBJECTIVES: We sought to elucidate the interaction between HTx listing weight and weight change while waitlisted, and explore how that interaction impacts post-HTx survival in a continuous manner. METHODS: Adult patients listed for HTx from 1987 to 2020 were identified from UNOS database. Three-dimensional restricted cubic spline analysis explored post-HTx survival relative to both changes in BMI/weight and BMI at time of HTx listing. Continuous predictor variables were analyzed with Cox proportional hazards method. RESULTS: 9,628 included patients underwent HTx. Median recipient age was 55 [IQR 46-62] years, and 21% were females. 53% of patients lost while 47% gained weight on the waitlist. Median BMI (27.6 kg/m2 [24.3-31.3] vs. 27.4 kg/m2 [24.2-30.9], paired p < 0.001) and weight (84.8 kg [73.0-98.0] kg vs. 84.4 kg [72.6-96.6], p < 0.001) were similar at listing and transplant. One-year survival was 89.3%. Weight loss over 3 BMI points or 10 kg was associated with higher hazard of death irrespective of listing BMI. In non-obese patients, some weight gain (1-4 BMI points or 5-15 kg) was associated with improved survival. In cachectic patients (BMI < 18.5), failure to gain weight was associated with worse survival. CONCLUSIONS: Impact of weight change varies depending on listing BMI. While a survival benefit is seen in non-obese patients who gain some weight, significant weight loss is associated with poorer survival.

2.
Artif Organs ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38887186

RESUMO

BACKGROUND: An inflammatory milieu after left ventricular assist device (LVAD) implantation is associated with multi-organ dysfunction and pre-operative heightened inflammatory state is associated with right ventricular failure after LVAD implantation. METHODS: We performed a retrospective analysis of 30 LVAD patients in our institution within the last 2 years for the development of fever and compared them to 30 non-LVAD open-heart surgery patients. RESULTS: Our results suggest that patients undergoing LVAD implantation are more likely to develop fever in the immediate post-operative period compared to other open-heart surgeries. This is independent of pharmacological treatment, age, or ethnical background. Females and obese patients were more likely to develop fever. CONCLUSION: Patients with right ventricular dysfunction, as demonstrated by elevated central venous pressure (CVP), had the strongest correlation with fever development. These results pose the question if there is a systemic inflammatory response-like phenomenon driven by increased right ventricular dysfunction.

3.
J Surg Res ; 300: 402-408, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38848640

RESUMO

INTRODUCTION: We sought to explore the relationship between various surgeon-related and hospital-level characteristics and clinical outcomes among patients requiring cardiac surgery. METHODS: We searched the New York State Cardiac Data Reporting System for all coronary artery bypass grafting (CABG) and valve cases between 2015 and 2017. The data were analyzed without dichotomization. RESULTS: Among CABG/valve surgeons, case volume was positively correlated with years in practice (P = 0.002) and negatively correlated with risk-adjusted mortality ratio (P = 0.014). For CABG and CABG/valve surgeons, our results showed a negative association between teaching status and case volume (P = 0.002, P = 0.018). Among CABG surgeons, hospital teaching status and presence of cardiothoracic surgery residency were inversely associated with risk-adjusted mortality ratio (P = 0.006, P = 0.029). CONCLUSIONS: There is a complex relationship between case volume, teaching status, and surgical outcomes suggesting that balance between academics and volume is needed.


Assuntos
Ponte de Artéria Coronária , Bases de Dados Factuais , Cirurgiões , Humanos , New York/epidemiologia , Bases de Dados Factuais/estatística & dados numéricos , Ponte de Artéria Coronária/estatística & dados numéricos , Ponte de Artéria Coronária/mortalidade , Cirurgiões/estatística & dados numéricos , Masculino , Feminino , Pessoa de Meia-Idade , Hospitais com Alto Volume de Atendimentos/estatística & dados numéricos , Idoso , Hospitais com Baixo Volume de Atendimentos/estatística & dados numéricos , Mortalidade Hospitalar , Internato e Residência/estatística & dados numéricos , Hospitais de Ensino/estatística & dados numéricos , Hospitais/estatística & dados numéricos , Resultado do Tratamento
4.
Artif Organs ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38803277

RESUMO

BACKGROUND: The Organ Procurement and Transplantation Network (OPTN) implemented modifications in 2018 to the adult heart transplant allocation system to better stratify the most medically urgent transplant candidates. We evaluated the impact of these changes on patients supported by a durable left ventricular assist device (LVAD) with chronic kidney disease (CKD). OBJECTIVE: To evaluate the impact of the OPTN policy change on patients supported by durable left ventricular assist devices (LVAD) with chronic kidney disease (CKD). METHODS: We performed an analysis of patients from the United Network of Organ Sharing Database supported by durable LVAD listed for a heart transplant (HT) between October 17, 2016 and September 30, 2021. Patients were divided into two groups: pre- and postpolicy, depending on whether they were listed on or prior to October 17, 2018. Patients who were on dialysis prior to surgery or discharge were excluded from the analysis. Patients with simultaneous heart and kidney transplants were excluded. Patients who were listed for transplant prepolicy change but transplanted postpolicy change were excluded. This cohort was then subdivided into degrees of CKD based on estimated glomerular filtration rate (eGFR), which resulted in 678 patients (23.7%) in Stage 1 (GFR ≥89.499) (Prepolicy: 345, Postpolicy: 333), 1233 (43.1%) in Stage 2 (89.499 > GFR ≥ 59.499) (Prepolicy: 618, Postpolicy: 615), 613 (21.4%) in Stage 3a (59.499 > GFR ≥ 44.499) (Prepolicy: 291, Postpolicy: 322), 294 (10.3%) in Stage 3b (44.499 > GFR ≥ 29.499) (Prepolicy: 143, Postpolicy: 151), 36 (1.3%) in Stage 4 (29.499 > GFR ≥ 15) (Prepolicy: 21, Postpolicy: 15), and 9 (0.3%) in Stage 5 (15 > GFR) (Prepolicy: 4, Postpolicy: 5). The primary outcome was 1-year and 2-year post-HT survival. RESULTS: There were 2863 patients who met the study criteria (1422 prepolicy, 1441 postpolicy). Overall survival, regardless of CKD stage, was lower following the policy change (p < 0.01). There was a similar risk of primary graft failure (PGF) in the pre- and postpolicy period (1.8% vs. 1.2%, p = 0.26). 1-year overall survival was 93% (91, 94) and 89% (87, 91) in the pre- and postpolicy periods, respectively. 2-year overall survival was 89% (88, 91) and 85% (82, 87) in the pre- and postpolicy periods, respectively. For CKD Stages 1, 2, 3a, 3b, 4, and 5, 1 -year survival was 93% (91, 95), 92% (90,93), 89% (86, 91), 89% (86, 93), 80% (68, 94), and 100% (100, 100), respectively. For CKD Stages 1, 2, 3a, 3b, 4, and 5, 2-year survival was 91% (88, 93), 88% (86, 90), 84% (81, 88), 84% (80, 89), 73% (59, 90), and 100% (100, 100), respectively. Patients with CKD 1 and 2 had better survival compared to those with CKD 3 (p < 0.01) and CKD 4 and 5 (p = 0.03) in the pre- and postpolicy periods. Patients with CKD 3 did not have a survival advantage over those with CKD 4 and 5 (p = 0.25). On cox regression analysis, advancing degrees of CKD were associated with an increased risk of mortality. CONCLUSIONS: Patients with LVAD support had decreased overall survival after the OPTN policy change. Patients with more advanced CKD had lower survival than patients without advanced CKD, though they were not impacted by the OPTN policy change.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38580322

RESUMO

BACKGROUND: Severe tricuspid regurgitation (TR) adversely affects long-term survival; however, isolated tricuspid valve (TV) surgery has been rarely performed due to high operative mortality. In addition, the previous literature included heterogeneous TR etiologies. Therefore, we aimed to elucidate early and long-term outcomes of isolated TV surgery for functional TR. METHODS: An electronic search was performed to identify all relevant studies. Baseline characteristics, perioperative variables, and clinical outcomes were extracted and pooled for meta-analysis. RESULTS: This meta-analysis included seven studies. Pooled analyses showed that 68% (35, 89) of patients had preoperative atrial fibrillation or flutter, and 58% (11, 94) had a history of left-sided valve surgery. Seventy-three percent (65, 80) of patients had at least one physical exam finding of right-sided heart failure, and 57% (44, 69) were in New York Heart Association class III or IV. TV replacement was more common than repair. In TV replacement, bioprosthetic valve (39%, 13, 74) was more common than mechanical prosthesis (22%, 18, 26). The early mortality rate was 7%. Twenty percent of patients required a permanent pacemaker postoperatively. The overall 1- and 5-year survival rates were 84.5 and 69.1%, respectively. CONCLUSION: More than half of the patients who underwent isolated TV surgery for functional TR had undergone left-sided valve surgery and had significant heart failure symptoms at the time of surgery. Further studies on the surgical indication for concomitant TV surgery at the time of left-sided valve surgery and the appropriate timing of surgery for isolated functional TR are needed to improve survival.

7.
J Thorac Dis ; 15(7): 3627-3635, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37559607

RESUMO

Background: Lung volume reduction (LVR) and lung transplantation (LTx) have been used in different populations of chronic obstructive pulmonary disease (COPD) patients. To date, comparative study of LVR and LTx has not been performed. We sought to address this gap by pooling the existing evidence in the literature. Methods: An electronic search was performed to identify all prospective studies on LVR and LTx published since 2000. Baseline characteristics, perioperative variables, and clinical outcomes were extracted and pooled for meta-analysis. Results: The analysis included 65 prospective studies comprising 3,671 patients [LTx: 15 studies (n=1,445), LVR: 50 studies (n=2,226)]. Mean age was 60 [95% confidence interval (CI): 58-62] years and comparable between the two groups. Females were 51% (95% CI: 30-71%) in the LTx group vs. 28% (95% CI: 21-36%) in LVR group (P=0.05). Baseline 6-minute walk test (6MWT) and pulmonary function tests were comparable except for the forced expiratory volume in 1 second (FEV1), which was lower in the LTx group [21.8% (95% CI: 16.8-26.7%) vs. 27.3% (95% CI: 25.5-29.2%), P=0.04]. Postoperatively, both groups experienced improved FEV1, however post-LTx FEV1 was significantly higher than post-LVR FEV1 [54.9% (95% CI: 41.4-68.4%) vs. 32.5% (95% CI: 30.1-34.8%), P<0.01]. 6MWT was also improved after both procedures [LTx: 212.9 (95% CI: 119.0-306.9) to 454.4 m (95% CI: 334.7-574.2), P<0.01; LVR: 286 (95% CI: 270.2-301.9) to 409.1 m (95% CI: 392.1-426.0), P<0.01], however, with no significant difference between the groups. Pooled survival over time showed no significant difference between the groups. Conclusions: LTx results in better FEV1 but otherwise has comparable outcomes to LVR.

8.
Artif Organs ; 47(10): 1559-1566, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37537953

RESUMO

BACKGROUND: Veno-arterial-venous extracorporeal membrane oxygenation (V-AV ECMO) is a less commonly used configuration of ECMO. We sought to understand the indications, utilization patterns, and outcomes of V-AV ECMO by quantitatively pooling the existing evidence from the literature. METHODS: Electronic search was performed to identify all relevant studies reporting V-AV ECMO usage. Five studies comprising 77 patients were selected and cohort-level data were extracted for further analysis. RESULTS: Mean patient age was 61 (95% CI: 55.2, 66.5) years and 30% (23/77) were female. The majority of cases [91% (70/77)] were transitioned to V-AV ECMO from another pre-existing ECMO configuration: V-A ECMO in 55% (42/77) vs. V-V ECMO in 36% (28/77), p = 0.04. Only 9% (7/77) of cases were directly placed on V-AV ECMO. The mean duration of hospital stay was 42.3 (95% CI: 10.5, 74.2) days, while ICU mortality was 46% (29, 64). Transition to durable left ventricular assist device was performed in 3% (2/64) of patients, while 3% (2/64) underwent heart transplantation. V-AV ECMO was successfully weaned to explantation in 33% (21/64) of patients. CONCLUSION: V-AV ECMO is a viable option for optimizing cardiopulmonary support in selected patients. Survival to weaning or bridging therapy appears comparable to more common ECMO configurations.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Coração Auxiliar , Humanos , Estudos Retrospectivos , Resultado do Tratamento
9.
Gen Thorac Cardiovasc Surg ; 71(12): 723-729, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37310563

RESUMO

OBJECTIVE: Although an ultrasonic harmonic scalpel (HS) has been used to harvest the internal mammary artery (IMA) for coronary artery bypass grafting, the benefits and risks compared to conventional electrocautery (EC) are not clear. We aimed to compare the outcomes of HS versus EC for IMA harvesting. METHODS: An electronic search was performed to identify all relevant studies. Baseline characteristics, perioperative variables, and clinical outcomes were extracted and pooled for meta-analysis. RESULTS: This meta-analysis included 12 studies. Pooled analyses demonstrated that both groups had comparable preoperative baseline characteristics including age, gender, and left ventricular ejection fraction. HS included more diabetic patients [33% (95% CI 30, 35) vs. 27% (23, 31), p = 0.01]. Harvest time for unilateral IMA was significantly longer with HS than EC [39 (31, 47) minutes vs. 25 (17, 33) minutes, p < 0.01]. However, the rate of pedicled unilateral IMA was significantly higher for EC compared with HS [20% (17, 24) vs. 8% (7, 9), p < 0.01]. The rate of intact endothelium was significantly higher with HS than EC [95% (88, 98) vs. 81% (68, 89), p < 0.01). There was no significant difference in postoperative outcomes including bleeding [3% (2, 4)], sternal infection [3% (2, 4)], and operative/30-day mortality [3% (2, 4)]. CONCLUSIONS: HS required longer IMA harvest times which could be partially attributed to a higher skeletonization rate in this category. HS may cause less endothelial injury than EC; however, no significant differences in postoperative outcomes were seen between the groups.


Assuntos
Artéria Torácica Interna , Ultrassom , Humanos , Volume Sistólico , Função Ventricular Esquerda , Eletrocoagulação/efeitos adversos
12.
Artif Organs ; 47(4): 770-776, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36448269

RESUMO

BACKGROUND: Improvement in continuous-flow left ventricular assist device (CF-LVAD) technology has translated to better outcomes for patients on CF-LVAD support as a bridge-to-transplant. However, data are lacking regarding the subset of CF-LVAD patients with renal failure awaiting simultaneous heart-kidney transplant (HKTx). We sought to better understand the characteristics and outcomes of patients in this group. METHODS: The United Network for Organ Sharing (UNOS) database was used to identify adult patients listed for heart transplant (HTx) or HKTx from January 1, 2009 to March 31, 2017. Patients were followed from time on waitlist to either removal from waitlist or transplantation. Demographic and clinical data for HTx and HKTx patients were assessed. Kaplan-Meier analysis assessed waitlist and post-transplant survival. For waitlisted patients, both death and removal from the waitlist due to deteriorating medical condition were considered events. RESULTS: Overall, 26 638 patients registered for transplant were analyzed. 25 111 (94%) were listed for HTx, and 1527 (6%) for HKTx. 7683 (29%) patients listed for HTx had CF-LVAD support. For those listed for HKTx, 441 (28%) underwent dialysis alone, 256 (17%) had CF-LVAD support alone, and 85 (6%) were treated with both CF-LVAD and dialysis. 15 567 (58%) underwent HTx, and 621 (2%) underwent HKTx. In these groups, post-transplant survival was similar (p = 0.06). Patients listed for HKTx treated with both dialysis and CF-LVAD had significantly worse waitlist survival compared to HKTx recipients (p < 0.001). CONCLUSION: Post-transplant survival is comparable between HTx and HKTx, and early survival is similar between HTx patients and those listed for HTx with CF-LVAD support. However, outcomes on the waitlist for HKTx in CF-LVAD patients on dialysis is significantly worse compared to HKTx recipients. This highlights the need to better account for this patient population when allocating organs.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Transplante de Rim , Adulto , Humanos , Transplante de Rim/efeitos adversos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Resultado do Tratamento , Transplante de Coração/efeitos adversos , Estudos Retrospectivos
14.
J Card Surg ; 37(12): 5172-5186, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36403254

RESUMO

There continues to be an unmet therapeutic need for an alternative treatment strategy for respiratory distress and lung disease. We are developing a portable cardiopulmonary support system that integrates an implantable oxygenator with a hybrid, dual-support, continuous-flow total artificial heart (TAH). The TAH has a centrifugal flow pump that is rotating about an axial flow pump. By attaching the hollow fiber bundle of the oxygenator to the base of the TAH, we establish a new cardiopulmonary support technology that permits a patient to be ambulatory during usage. In this study, we investigated the design and improvement of the blood flow pathway from the inflow-to-outflow of four oxygenators using a mathematical model and computational fluid dynamics (CFD). Pressure loss and gas transport through diffusion were examined to assess oxygenator design. The oxygenator designs led to a resistance-driven pressure loss range of less than 35 mmHg for flow rates of 1-7 L/min. All of the designs met requirements. The configuration having an outside-to-inside blood flow direction was found to have higher oxygen transport. Based on this advantageous flow direction, two designs (Model 1 and 3) were then integrated with the axial-flow impeller of the TAH for simulation. Flow rates of 1-7 L/min and speeds of 10,000-16,000 RPM were analyzed. Blood damage studies were performed, and Model 1 demonstrated the lowest potential for hemolysis. Future work will focus on developing and testing a physical prototype for integration into the new cardiopulmonary assist system.


Assuntos
Coração Artificial , Oxigenadores , Humanos , Desenho de Equipamento , Hemodinâmica
16.
Ann Cardiothorac Surg ; 11(3): 226-238, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35733719

RESUMO

Background: Surgical ventricular reconstruction (SVR) has been used to control adverse ventricular remodeling and improve cardiac function in ischemic cardiomyopathy. The purpose of this systematic review and meta-analysis was to collect and analyze all available evidence on the utilization and efficacy of SVR. Methods: An electronic database search was performed to identify all retrospective and prospective studies on SVR for ischemic cardiomyopathy in the English literature from 2000 through 2020. A total of 92 articles with a collective 7,685 patients undergoing SVR were included in the final analysis. Results: The mean patient age was 61 years (95% CI: 59-63) and 80% (78-82%) were male. Congestive heart failure was present in 66% (54-78%) and angina in 58% (45-70%). Concomitant coronary artery bypass grafting was undertaken in 92% (90-93%) while 21% (18-24%) underwent mitral valve repair. Pre vs. post-SVR, significant improvement was seen in left ventricular ejection fraction (LVEF) [29.9% (28.8-31.2%) vs. 40.9% (39.4-42.4%), P<0.01], left ventricular end-systolic (LVESD) and end-diastolic diameters (LVEDD) [LVESD: 49.9 mm (48.1-51.7) vs. 45 mm (42.8-47.3), P<0.01, LVEDD: 63.8 mm (62-65.6) vs. 58.23 mm (56.6-60), P<0.01], and left ventricular end-systolic (LVESVI) and end-diastolic volume indices (LVEDVI) [LVESVI: 83.9 mL/m2 (79.3-88.4) vs. 46.8 mL/m2 (43.5-50.1), P<0.01; LVEDVI: 119.9 mL/m2 (112.1-127.6) vs. 79.6 mL/m2 (73.6-85.7), P<0.01]. Mean New York Heart Association class improved from 3 (2.8-3.1) to 1.8 (1.5-2) (P<0.01). The 30-day mortality was 4% (3-5%) while late mortality was 19% (9-34%) at a mean follow-up of 27.5 [21-34] months. Conclusions: In patients with ischemic cardiomyopathy, SVR reduces left ventricular volumes and improves systolic function leading to symptomatic improvement.

17.
Artif Organs ; 46(3): 362-374, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34633690

RESUMO

BACKGROUND: Major airway surgery can pose a complex problem to perioperative central airway management. Adjuncts to advanced ventilation strategies have included cardiopulmonary bypass, veno-arterial, or veno-venous extracorporeal life support. We performed a systematic review to assess the existing evidence utilizing these strategies. METHODS: An electronic search was conducted to identify studies written in English reporting the use of extracorporeal life support (ECLS) during central airway surgery. Thirty-six articles consisting of 78 patients were selected and patient-level data were analyzed. RESULTS: Median patient age was 47 [IQR: 34-53] and 59.0% (46/78) were male. Indications for surgery included central airway or mediastinal cancer in 57.7% (45/78), lesion or injury in 15.4% (12/78), and stenosis in 12.8% (10/78). Support was initiated pre-operatively in 9.9% (7/71) and at the time of induction in 55.3% (42/76). It was most commonly used at the time of tracheal resection/repair [93.2% (68/73)], intubation of the tracheal stump [94.4% (68/72)], and re-anastomosis [94.2% (65/69)]; 13.7% (10/73) patients were supported post-operatively. The most commonly performed surgery was tracheal repair or resection in 70.3% (52/74). Median hospital stay was 12 [8, 25] days and in-hospital mortality was 7.9% (6/76). There was no significant difference in survival between the three groups (p = .54). CONCLUSIONS: Extracorporeal membrane oxygenation offers versatility in timing, surgical approach, and ECLS runtime that makes it a viable addition to the surgical armamentarium for treating complex central airway pathologies.


Assuntos
Manuseio das Vias Aéreas/métodos , Ponte Cardiopulmonar , Oxigenação por Membrana Extracorpórea , Sistema Respiratório/cirurgia , Humanos
18.
Transplant Rev (Orlando) ; 36(1): 100672, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34826752

RESUMO

PURPOSE: Infective endocarditis (IE) is a rare but potentially fatal complication following heart transplantation (HTx). There is a lack of literature regarding the patterns and clinical course of IE development following HTx. We sought to pool the existing data in regards to defining characteristics, management options, and outcomes of IE following HTx. METHODS: An electronic search of Cochrane Central Register of Controlled Trials, Cumulative Index to Nursing and Allied Health Literature, Ovid Medline, and the Scopus databases were performed to identify all articles in the English literature that report IE following HTx in adult patients. Patient-level data were extracted and analyzed. RESULTS: Systematic search yielded 57 patients from 32 articles. Median patient age was 52 [IQR 43, 59] and 75% of patients (43/57) were male. Median time to IE presentation post-HTx was 8.4 [IQR 3.0, 35.8] months. IE of the mitral valve was observed in 36.8% (21/57) of patients, followed by mural IE in 24.6% (14/57), and tricuspid valve IE in 21.1% (12/57). The most common organisms were Staphylococcus aureus in 26.3% (15/57), Aspergillus fumigatus in 19.3% (11/57), Enterococcus faecalis in 12.3% (7/57), and an undetermined or unspecified organism in 14.0% (8/57) patients. Overall case fatality was 44.6% (25/56). Fungal IE was associated with a significantly higher case fatality 75.0% (9/12) than that of bacterial IE 36.1% (13/36) (p = 0.02). Surgical management of post-HTx IE was observed in 35.1% (20/57) of patients. This included valve surgery for 70.0% (14/20), including the mitral valve in 50.0% (7/14), aortic valve in 35.7% (5/14), and the tricuspid valve in 14.3% (2/14) of patients. CONCLUSION: In addition to bacterial organisms, fungi also represent a frequent cause of IE in post-HTx patients. Overall HTx patient survival in the setting of IE is poor and may be worse if caused by A. fumigatus.


Assuntos
Endocardite Bacteriana , Endocardite , Transplante de Coração , Infecções Estafilocócicas , Adulto , Endocardite/microbiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/microbiologia , Transplante de Coração/efeitos adversos , Humanos , Masculino , Infecções Estafilocócicas/complicações , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus
19.
Ann Cardiothorac Surg ; 10(3): 301-310, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34159112

RESUMO

BACKGROUND: With increased use of continuous-flow left ventricular assist devices (CF-LVAD), development of malignant tumors in this population is not uncommon. We sought to evaluate malignancies in CF-LVAD patients and evaluate the outcomes of treatment strategies. METHODS: Overall, 18 articles consisting of 28 patients were identified who developed malignancies after CF-LVAD placement. Patient-level data were extracted for systematic review. RESULTS: Median patient age was 60 years [59-67] and 85.7% (24/28) were male. CF-LVAD was placed as bridge-to-transplant (BTT) in 60.9% (14/23) of patients. The three most common malignancy types were GI in 35.7% (10/28) of patients, lung in 21.4% (6/28) and skin in 10.7% (3/28). Median time from CF-LVAD implant to malignancy diagnosis was 6.9 [2.5-12.8] months. Metastatic disease occurred in 17.9% (5/28) over a median time of 5.0 [1.0-82.0] months from the diagnosis. Surgical resection of the malignancy was performed in 57.1% (16/28) of patients. Our results showed that while there was a significantly higher probability of survival among patients who underwent surgery versus those who did not, when only stage I and II patients were included in the analysis, this difference was no longer statistically significant. Three patients were relisted for heart transplant after surgical treatment, and two received the transplant. CONCLUSIONS: Surgical management of malignancies in patients on CF-LVADs may improve survival and transplant eligibility status, therefore, a CF-LVAD should not always preclude surgical treatment.

20.
Ann Cardiothorac Surg ; 10(3): 375-382, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34159118

RESUMO

BACKGROUND: The impact of left ventricular assist device (LVAD) complications on the individual patient, overall sentiment, and its effect on referral patterns, is not fully understood. We sought to better understand patient attitudes towards LVAD therapy using a computational sentiment analysis approach. METHODS: Posts, comments, and titles were parsed from MyLVAD.com's HTML as a text file using custom Python scripts (version 3.6). Individual word frequency was computed with word classification as 'positive', 'negative', or 'neutral'. Data transformation and cleaning, sentiment determination, and analysis was performed with a binary dictionary package using R software (version 3.6). RESULTS: Sixty-six thousand eight hundred and twenty-one unique words were noted, including 4,623 (6.9%) with positive sentiment and 3,248 (4.8%) with negative sentiment. Net sentiment ratio [(number of positive words - number of negative words)/(number of total words)] was 2.1%. Positive sentiment dominated the 20 most commonly used words. Odds ratio of non-neutral words [(number of positive words/number of negative words)] was 1.42, indicating a less obvious disparity in sentiment when expanding analysis beyond the top 20 words. Word cloud analysis of positive and negative sentiments was performed, indicating common use of "infection" (208 mentions) compared to other complications such as "stroke" (29 mentions), "bleeding" (30 mentions), and "thrombosis" or "clot" (32 mentions). CONCLUSIONS: Positive sentiment dominates the most frequently used words, yet this disparity decreases when considering the totality of words. "Infection" is mentioned a disproportionate number of times compared to other LVAD complications. Further research is required to address analysis limitations, including selection bias.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA