Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Surg Res ; 231: 99-108, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30278975

RESUMO

BACKGROUND: Specialized tourniquets have been deployed to the battlefield for the control of junctional/pelvic hemorrhage despite limited knowledge concerning their safety and duration of use. This study investigated long-term effects of abdominal application of the abdominal aortic and junctional tourniquet (AAJT) in a swine survival model. METHODS: Anesthetized spontaneously air-breathing swine were subjected to bilateral femoral artery injuries and subsequent 40% hemorrhage. Further hemorrhage was controlled by applying the AAJT on the lower abdomen for 0 h (n = 2, controls), 1 h (n = 6), 1.5 h (n = 6), or 2 h (n = 3). Before tourniquet release, arterial injuries were repaired, and mechanical ventilation and rapid crystalloid fluid were provided for at least 5 min. Additional fluid and 500 mL autologous blood were transfused after restoring blood flow. Animals were recovered and their mobility and health monitored up to 2 wk. RESULTS: AAJT application occluded the infrarenal abdominal aorta and stopped bilateral groin hemorrhage with rapid reversal of hemorrhagic shock and improved cranial blood pressure. All animals including controls recovered overnight but regaining hind leg function varied among AAJT-treated groups. In contrast to 1 h AAJT-treated swine that recovered full mobility in 1 wk, 2 h animals developed persistent hind leg paraplegia concurrent with urinary retention and ischemic necrosis of lumber muscles and had to be euthanized 3 d after surgery. Half of the 1.5-h group also had to be euthanized early due to paraplegia, whereas the other half recovered motor function within 2 wk. CONCLUSIONS: The results of this animal study indicated that ischemic reperfusion injuries associated with abdominal application of the AAJT were time-dependent. To avoid permanent injuries, AAJT application on the abdomen to control a groin hemorrhage could not be longer than 1 h. This was consistent with recent instructions for application of this tourniquet on the abdomen in patients.


Assuntos
Aorta Abdominal , Hemorragia/terapia , Extremidade Inferior/irrigação sanguínea , Traumatismo por Reperfusão/etiologia , Torniquetes/efeitos adversos , Animais , Feminino , Marcha , Hemodinâmica , Paraplegia/etiologia , Postura , Traumatismo por Reperfusão/sangue , Suínos , Fatores de Tempo
2.
J Trauma Acute Care Surg ; 83(1): 182-189, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28422911

RESUMO

OBJECTIVE: Airways compromise was the second leading cause of potentially preventable death among combat casualties. We investigated the ability of five Food and Drug Administration-approved nonocclusive chest seals (CSs) to seal a bleeding chest wound and prevent tension hemopneumothorax (HPTX) in a swine model. METHODS: Following instrumentation, an open chest wound was created in the left thorax of spontaneously air-breathing anesthetized pigs (n = 26; 43 kg). Autologous fresh blood (226 mL) was then infused into the pleural cavity to produce HPTX. The chest wounds were then sealed with CSs. The sealant strength and venting function of CSs were challenged by infusion of 50 mL more blood directly into the chest wound and incremental air injections into the pleural cavity. Tension HPTX was defined as intrapleural (IP) pressure equal to or more than +1 mm Hg and more than 20% deviation in physiologic measurements. RESULTS: An open chest wound with HPTX raised IP pressure (~ -0.7 mm Hg) and caused labored breathing and reductions in PaO2 and SvO2 (p < 0.01). Sealing the wounds with the CSs restored IP pressure, and improved breathing and oxygenation. Subsequent blood infusion into the wound and IP air injections produced CS-dependent responses. Chest seals with one-way valves (Bolin and SAM) did not evacuate the blood efficiently; pooled blood either detached the CSs from skin and leaked out (75%), or clotted and clogged the valve and led to tension HPTX (25%). Conversely, CSs with laminar venting channels allowed escape of blood and air from the pleural cavity and maintained IP pressure and oxygenation near normal levels. Success rates were 100% for Sentinel and Russell (6/6); 67% for HyFin (4/6); 25% for SAM (1/4); and 0% for Bolin (0/4) CSs (p = 0.002). CONCLUSION: The sealant and valve function of vented CS differed widely in the presence of bleeding chest wounds. Medics should be equipped with more effective CSs for treating HPTX in the field.


Assuntos
Drenagem/instrumentação , Hemopneumotórax/prevenção & controle , Curativos Oclusivos , Animais , Pressão Arterial , Modelos Animais de Doenças , Teste de Materiais , Medicina Militar , Suínos
3.
J Trauma Acute Care Surg ; 82(1): 156-164, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27779578

RESUMO

BACKGROUND: Prehospital, small-volume resuscitation of combat casualties with a synthetic colloid (6% hydroxyethyl starch [HES] 670/0.75) has been recommended when blood or blood components are unavailable. We studied hemostatic effects of a newer synthetic colloid (6% HES, 130/0.4) compared with either a natural colloid (albumin) or to crystalloids in an uncontrolled hemorrhage model. METHODS: Spontaneously breathing New Zealand white rabbits (3.4 ± 0.1 kg) were anesthetized, instrumented, and subjected to a splenic injury with uncontrolled bleeding. Fifteen minutes after injury, rabbits were in shock (mean arterial pressure [MAP] = 26 ± 1.3 mm Hg, and received colloids (6% HES, 130/0.4 or 5% albumin at 15 mL/kg), or crystalloids (normal saline at 30 mL/kg or 5% hypertonic saline at 7.5 mL/kg) for resuscitation in two intravenous bolus injections (15 minutes apart) to raise their MAP to 65 mm Hg, n = 9/group. Animals were monitored for 2.5 hours or until death, and blood losses were measured. Blood samples were analyzed for arterial blood gas, complete blood count, and coagulation measures. RESULTS: There were no differences among groups in baseline measures and initial hemorrhage volume (11.9 ± 0.6 mL/kg) at 15 minutes postinjury. Twenty minutes after fluid resuscitation (1 hour postinjury), MAP was higher, shock indices were lower, and blood pH was higher in colloids versus. crystalloids groups (p < 0.05). Administration of 6% HES 130/0.4 colloid produced the largest hemodilution (54% decrease in hematocrit, p < 0.05 vs. hypertonic saline). Activated partial thromboplastin time increased approximately 35% above baseline in all groups except in 6% HES 130/0.4 group in which it doubled. Clot strength was reduced (15%) only in the 6% HES 130/0.4 group. 6% HES 130/0.4 resuscitation produced the largest blood loss and 33% survival rate that was not different than the crystalloid groups. Albumin produced the best hemostatic and survival outcomes (78%). CONCLUSION: Small-volume resuscitation with crystalloids appeared inadequate to treat hypovolemic shock and prevent death. 6% HES 130/0.4 was effective hemodynamically but detrimental to hemostasis. Albumin produced the best outcomes consistent with our previous observations. Further studies are needed to prove benefit of albumin solution as a possible resuscitation fluid for treating combat casualties at the point of injury.


Assuntos
Albuminas/farmacologia , Coloides/farmacologia , Hemostasia/efeitos dos fármacos , Derivados de Hidroxietil Amido/farmacologia , Soluções Isotônicas/farmacologia , Ressuscitação/métodos , Solução Salina Hipertônica/farmacologia , Choque Hemorrágico/tratamento farmacológico , Animais , Soluções Cristaloides , Modelos Animais de Doenças , Masculino , Coelhos
4.
J Trauma Acute Care Surg ; 81(1): 42-9, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27120325

RESUMO

BACKGROUND: Plasma infusion with or without red blood cells is the current military standard of care for prehospital resuscitation of combat casualties. We examined possible advantages of early and limited resuscitation with fresh plasma compared with a single plasma protein or crystalloid solutions in an uncontrolled hemorrhage model in rabbits. METHODS: Anesthetized spontaneously breathing rabbits (3.3 ± 0.1 kg) were instrumented and subjected to a splenic uncontrolled hemorrhage. Rabbits in shock were resuscitated at 15 minutes with Plasma-Lyte (PAL; 30 mL/kg), PAL + fibrinogen (PAL + F; 30 mL + 100 mg/kg), fresh rabbit plasma (15 mL/kg), or 25% albumin (ALB; 5 mL/kg) solution, all given in two bolus intravenous injections (15 minutes apart) to achieve a mean arterial pressure of 65 mm Hg, n = 8 to 9/group. Animals were monitored for 2 hours or until death, and blood loss was measured. Blood samples and tissues were collected and analyzed. RESULTS: There were no differences among groups in baseline measures and their initial bleeding volume at 15 minutes. At 60 minutes after injury, mean arterial pressure was higher with ALB than with crystalloids (PAL or PAL + F), but shock indices were not different despite the large differences in resuscitation volumes. Fibrinogen addition to PAL only increased clot strength. Plasma resuscitation increased survival rate (75%) without significant improvement in coagulation measures. Albumin administration replenished total plasma protein and increased survival rate to 100% (p < .05 vs. crystalloids). No histological adverse events were identified in the vital organs. CONCLUSIONS: Fibrinogen administration added to a compatible crystalloid did not improve hemostatic outcomes. Plasma resuscitation increased survival rate; however, its effects did not differ from those obtained with 25% ALB at one-third of the volume. The ALB advantage was consistent with our previous findings in which 5% ALB was used at a volume equal to plasma. The benefit of plasma for resuscitation may be mostly due to its ALB content rather than its coagulation proteins.


Assuntos
Hemorragia/terapia , Hemostáticos/farmacologia , Plasma , Ressuscitação/métodos , Animais , Soluções Cristaloides , Modelos Animais de Doenças , Gluconatos/farmacologia , Hemorragia/mortalidade , Soluções Isotônicas/farmacologia , Cloreto de Magnésio/farmacologia , Masculino , Cloreto de Potássio/farmacologia , Coelhos , Acetato de Sódio/farmacologia , Cloreto de Sódio/farmacologia , Taxa de Sobrevida
5.
J Trauma Acute Care Surg ; 78(4): 752-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25807404

RESUMO

BACKGROUND: Reports of survival benefits of early transfusion of plasma with red blood cells (1:1 ratio) in trauma patients suggest that plasma may be a better fluid to replace Hextend for battlefield resuscitation. We studied possible advantages of prehospital resuscitation with plasma compared with Hextend or albumin in a model of uncontrolled hemorrhage. METHODS: Male New Zealand white rabbits (3.3 ± 0.1 kg) were anesthetized, instrumented, and subjected to a splenic injury with uncontrolled bleeding. Ten minutes after injury (mean arterial pressure [MAP] < 40 mm Hg), the rabbits received small and equal volumes (15 mL/kg) of rabbit plasma (n = 10), Hextend (n = 10), or 5% human albumin (n = 9) or no fluid. Fluids were administered in two bolus injections (20 minutes apart) and targeted to a MAP of 65 mm Hg. Animals were monitored for 2.5 hours or until death, and their blood losses were measured. Arterial blood samples were collected at different times and analyzed for ABG, CBC, and coagulation tests. RESULTS: There were no differences in baseline measures among groups. Splenic injury caused similar hemorrhages (9.1 ± 0.4 mL/kg at 10 minutes) and decreased MAP in all subjects. Subsequent resuscitation initiated additional bleeding. At 60 minutes after injury (20 minutes after resuscitation), longer activated partial thromboplastin time and lower fibrinogen concentrations were apparent compared with baseline values with differences among groups. Thrombelastography analysis indicated faster and stronger clot formation with plasma and albumin resuscitation than with Hextend use. Shock indices were increased in all groups, but smaller changes were measured in the albumin group. Total blood loss did not differ among resuscitated rabbits but was higher (p < 0.05) than among nonresuscitated animals. Survival rates were 11% (untreated), 40% (Hextend and plasma), and 89% (albumin, p < 0.05). CONCLUSION: Resuscitation with plasma or albumin better preserved coagulation function than did Hextend. However, despite these improvements, plasma resuscitation did not reduce blood loss or improve survival, while albumin administration seemed beneficial.


Assuntos
Albuminas/farmacologia , Coloides/farmacologia , Hidratação/métodos , Hemorragia/terapia , Derivados de Hidroxietil Amido/farmacologia , Plasma , Ressuscitação/métodos , Animais , Serviços Médicos de Emergência , Hemorragia/etiologia , Masculino , Tempo de Tromboplastina Parcial , Coelhos , Baço/lesões , Taxa de Sobrevida
6.
J Trauma Acute Care Surg ; 77(3 Suppl 2): S101-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25159342

RESUMO

BACKGROUND: Groin application of Combat Ready Clamp (CRoC) in pigs elicits an acute inflammation in underlying ischemic tissues. This study examined functional recovery of pigs' hind leg(s) following 2 hours of CRoC application. METHODS: Left femoral arteries were isolated and injured in anesthetized pigs. Following 25% hemorrhage, CRoC was applied on the inguen for 2 hours (n = 6), and wounds were covered with combat gauze (CG). Bleeding was treated in the control animals (n = 5) with CG only. Next, CRoC and CG were removed, arteries were repaired and reflowed, and animals were recovered. The legs' mobility was scored daily, and their neuromuscular functions were measured on Days 7 and 14. Computed tomographic angiography and blood analysis were performed on Days 0, 2, 7, and 14. Pigs were then euthanized, and tissues were collected for histology. Umbilicus application of CRoC was also tested in four pilot experiments. RESULTS: Inguinal application of CRoC with 524 ± 12 mm Hg pressure occluded iliac arteries and collateral circulation. Following surgical repair, blood flow to the arteries was restored, and five of six CRoC-applied legs recovered full mobility within 9 days. Control-treated legs recovered full function in 3 days (p = 0.001). At 2 weeks, muscle strength of CRoC-applied legs was diminished (p < 0.05 vs. baselines or controls). Injury biomarkers in the CRoC group increased severalfold compared with the controls on Day 2 but returned to baseline afterward. Histologic changes were mostly mild and indicative of ischemia in the CRoC group. Umbilical application of CRoC required higher pressure (625 ± 8 mm Hg) and caused gross ischemic necrosis of lumbar muscles with significant disabilities. CONCLUSION: Two-hour inguinal application of CRoC caused mild and reversible ischemic injuries, which delayed full recovery of the limb function by a few days. In contrast, 2-hour umbilicus application of CRoC resulted in extensive muscle necrosis with functional disabilities. While CRoC seems safe and effective for inguinal application, other tourniquets should be evaluated for treating bilateral junctional bleeding.


Assuntos
Artéria Femoral/lesões , Hemorragia/terapia , Técnicas Hemostáticas/instrumentação , Extremidade Inferior/lesões , Torniquetes , Animais , Feminino , Virilha , Isquemia/etiologia , Isquemia/fisiopatologia , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/fisiopatologia , Suínos , Torniquetes/efeitos adversos
7.
J Trauma Acute Care Surg ; 75(1): 150-6, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23940861

RESUMO

BACKGROUND: Unvented chest seals (CSs) are currently recommended for the management of penetrating thoracic injuries in the battlefield. Since no supporting data exist, we compared the efficacy of a preferred unvented with that of a vented CS in a novel swine model of pneumothorax (PTx). METHODS: An open chest wound was created in the left thorax of spontaneously air-breathing anesthetized pigs (n = 8). A CS was applied over the injury, then tension PTx was induced by incremental air injections (0.2 L) into the pleural cavity via a cannula that was also used to measure intrapleural pressure (IP). Both CS were tested on each pig in series. Tidal volume (V(T)), respiratory rate, IP, heart rate, mean arterial pressure, cardiac output, central venous pressure, pulmonary arterial pressure, venous and peripheral oxygen saturations (SvO2, SpO2) were recorded. Tension PTx was defined as a mean IP equal to or greater than +1 mm Hg plus significant (20-30%) deviation in baseline levels of the previously mentioned parameters and confirmed by chest x-ray study. PaO2 and PaCo2 were also measured. RESULTS: PTx produced immediate breathing difficulty and significant rises in IP and pulmonary arterial pressure and falls in V(T), SpO2, and SvO2. Both CSs returned these parameters to near baseline within 5 minutes of application. After vented CS was applied, serial air injections up to 2 L resulted in no significant change in the previously mentioned parameters. After unvented CS application, progressive deterioration of all respiratory parameters and onset of tension PTx were observed in all subjects after approximately 1.4-L air injection. CONCLUSION: Both vented and unvented CSs provided immediate improvements in breathing and blood oxygenation in our model of penetrating thoracic trauma. However, in the presence of ongoing intrapleural air accumulation, the unvented CS led to tension PTx, hypoxemia, and possible respiratory arrest, while the vented CS prevented these outcomes.


Assuntos
Pneumotórax/terapia , Traumatismos Torácicos/terapia , Adesivos Teciduais/uso terapêutico , Animais , Pressão Arterial , Modelos Animais de Doenças , Feminino , Pneumotórax/etiologia , Pneumotórax/fisiopatologia , Troca Gasosa Pulmonar , Distribuição Aleatória , Respiração Artificial/métodos , Medição de Risco , Sensibilidade e Especificidade , Taxa de Sobrevida , Traumatismos Torácicos/complicações , Resultado do Tratamento
8.
J Trauma Acute Care Surg ; 74(5): 1260-5, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23609276

RESUMO

BACKGROUND: Junctional wounds and associated hemorrhage have become more common and more lethal in the current war. The Combat Ready Clamp (CRoC) has been developed and deployed for treating junctional hemorrhage on the battlefield. This study examined the efficacy of CRoC and its acute effects in an animal model. METHODS: Anesthetized pigs (n = 6) were subjected to laparotomy, splenectomy, and abdominal closure. Next, coagulopathy was induced in animals by hemodilution and hypothermia. The left femoral artery was isolated, punctured (6-mm hole), and allowed to bleed for 15 seconds. The groin wound was packed with gauze, and a CRoC applied and tightened until hemorrhage stopped. It was kept in place for 1 hour (treatment period) and then released for another hour or less (control-period) if animal exsanguinated. Fluid resuscitation was administered, and vascular blood flow was examined by Doppler and CT scans. After death, local tissues were collected for histology. RESULTS: CRoC generated 800 to 900 mm Hg pressure on the wounds, which stopped the hemorrhage and prevented rebleeding during the first hour in all animals. Blood loss was minimal (≤137 mL), and mean arterial pressure remained at or higher than the target level (65 mm Hg) during this period. Removal of the clamp promptly led to rebleeding and exsanguination of five of six pigs during the second hour despite fluid resuscitation. Blood loss, survival, shock indices, and other measures were significantly (p < 0.01) different between the two periods. Doppler tests and CT scans showed no blood flow in the proximal, distal, and collateral arteries of the clamped leg. Minor inflammation was seen on blood vessels (endothelium) and nerves. CONCLUSION: CRoC functioned as an effective hemostatic adjunct for compression and control of groin hemorrhage. Although no acute histological damages were seen in compressed tissues, the short- and long-term effects of CRoC application (e.g., total ischemia) on limb function remain unknown and warrant investigation.


Assuntos
Exsanguinação/terapia , Torniquetes , Animais , Modelos Animais de Doenças , Exsanguinação/diagnóstico por imagem , Feminino , Virilha/diagnóstico por imagem , Virilha/lesões , Suínos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia
9.
J Trauma Acute Care Surg ; 73(5): 1188-94, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23117379

RESUMO

BACKGROUND: Negative-pressure wound therapy has been commonly used for treating chronic wounds and recently applied for treatment of traumatic wounds. We investigated the potential hemostatic benefit of negative-pressure wound therapy for control of refractory hemorrhage in a soft tissue wound model in swine. METHODS: Coagulopathy was induced in pigs (n = 38, 36 kg) by hemodilution and hypothermia. Next, a large soft tissue wound (diameter, approximately 20 cm) was created by slicing the gluteus maximus muscle. Free bleeding was allowed for 1 minute, and wounds were then randomly dressed with either laparotomy gauze (G) alone or TraumaPad (TP, a kaolin-coated dressing) alone or in combination with negative pressure (NP, approximately -500 mm Hg). All wounds were sealed with adhesive drapes. Fluid resuscitation was administered and targeted to mean arterial pressure of 60 mm Hg. Pigs were observed for 150 minutes or until death after which tissues were sampled for histologic examination. RESULTS: Induced coagulopathy as measured by increases in prothrombin time (12%) and activated partial thromboplastin time (22%) and decreases in fibrinogen (48%) were similar in all groups. There were no differences in initial bleeding rates (4.5 mL/kg/min). Dressing the wounds with G or TP produced hemostasis only in one pig (1 of 18 pigs). Addition of NP to these dressings secured hemostasis in 70% (G) and 90% (TP) of animals with average hemostasis time of 34 minutes and 25 minutes, respectively. Blood losses and fluid resuscitation requirements were significantly less, and survival times were significantly longer in NP adjunct groups than in the other groups. Survival rates were 80% (G+NP) and 90% (TP+NP) versus 0% (G) and 10% (TP) in the respective groups. Histologic examination showed similar superficial myofibril damages in all groups. CONCLUSION: To our knowledge, the present data provide the first evidence that NP serves as an effective hemostatic adjunct and when combined with standard hemostatic dressing it is able to stop lethal coagulopathic bleeding in large soft tissue wounds.


Assuntos
Traumatismos por Explosões/terapia , Transtornos da Coagulação Sanguínea/terapia , Hemorragia/prevenção & controle , Técnicas Hemostáticas , Tratamento de Ferimentos com Pressão Negativa , Lesões dos Tecidos Moles/terapia , Animais , Traumatismos por Explosões/complicações , Traumatismos por Explosões/patologia , Transtornos da Coagulação Sanguínea/complicações , Transtornos da Coagulação Sanguínea/patologia , Modelos Animais de Doenças , Explosões , Hemorragia/etiologia , Hemorragia/patologia , Masculino , Lesões dos Tecidos Moles/complicações , Lesões dos Tecidos Moles/patologia , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA