Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Diagnostics (Basel) ; 13(9)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37174932

RESUMO

Background: On the basis of the hypothesis that virtual noniodine (VNI)-based coronary artery calcium scoring (CACS) is feasible at reduced radiation doses, this study assesses the impact of radiation dose reduction on the accuracy of this VNI algorithm on a photon-counting detector (PCD)-CT. Methods: In a systematic in vitro setting, a phantom for CACS simulating three chest sizes was scanned on a clinical PCD-CT. The standard radiation dose was chosen at volumetric CT dose indices (CTDIVol) of 1.5, 3.3, 7.0 mGy for small, medium-sized, and large phantoms, and was gradually reduced by adjusting the tube current resulting in 100, 75, 50, and 25%, respectively. VNI images were reconstructed at 55 keV, quantum iterative reconstruction (QIR)1, and at 60 keV/QIR4, and evaluated regarding image quality (image noise (IN), contrast-to-noise ratio (CNR)), and CACS. All VNI results were compared to true noncontrast (TNC)-based CACS at 70 keV and standard radiation dose (reference). Results: INTNC was significantly higher than INVNI, and INVNI at 55 keV/QIR1 higher than at 60 keV/QIR4 (100% dose: 16.7 ± 1.9 vs. 12.8 ± 1.7 vs. 7.7 ± 0.9; p < 0.001 for every radiation dose). CNRTNC was higher than CNRVNI, but it was better to use 60 keV/QIR4 (p < 0.001). CACSVNI showed strong correlation and agreement at every radiation dose (p < 0.001, r > 0.9, intraclass correlation coefficient > 0.9). The coefficients of the variation in root-mean squared error were less than 10% and thus clinically nonrelevant for the CACSVNI of every radiation dose. Conclusion: This phantom study suggests that CACSVNI is feasible on PCD-CT, even at reduced radiation dose while maintaining image quality and CACS accuracy.

2.
Clin Cardiol ; 44(11): 1636-1645, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34651337

RESUMO

BACKGROUND: Left atrial appendage (LAA) is a potential source of atrial fibrillation (AF) triggers. HYPOTHESIS: LAA morphology and dimensions are associated with AF recurrence after pulmonary vein isolation (PVI). METHODS: From cardiac computed tomography angiography (CCTA), left atrial (LA), pulmonary vein (PV), and LAA anatomy were assessed in cryoballoon ablation (CBA) patients. RESULTS: Among 1103 patients undergoing second-generation CBA, 725 (65.7%) received CCTA with 473 (42.9%) qualifying for detailed LAA analysis (66.3 ± 9.5 years). Symptomatic AF reoccurred in 166 (35.1%) patients during a median follow-up of 19 months. Independent predictors of recurrence were LA volume, female sex, and mitral regurgitation ≥°II. LAA volume and AF-type were dependent predictors of recurrence due to their strong correlations with LA volume. LA volumes ≥122.7 ml (sensitivity 0.53, specificity 0.69, area under the curve [AUC] 0.63) and LAA volumes ≥11.25 ml (sensitivity 0.39, specificity 0.79, AUC 0.59) were associated with recurrence. LA volume was significantly smaller in females. LAA volumes showed no sex-specific difference. LAA morphology, classified as windsock (51.4%), chicken-wing (20.7%), cactus (12.5%), and cauliflower-type (15.2%), did not predict successful PVI (log-rank; p = 0.596). CONCLUSIONS: LAA volume was strongly correlated to LA volume and was a dependent predictor of recurrence after CBA. Main independent predictors were LA volume, female sex, and mitral regurgitation ≥°II. Gender differences in LA volumes were observed. Individual LAA morphology was not associated with AF recurrence after cryo-PVI. Our results indicate that preprocedural CCTA might be a useful imaging modality to evaluate ablation strategies for patients with recurrences despite successful PVI.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 32(4): 949-957, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33644913

RESUMO

INTRODUCTION: The objective was to analyze the impact of patient age on clinical characteristics, procedural results, safety, and outcome of cryoballoon ablation (CBA) as the primary approach in the interventional treatment of symptomatic atrial fibrillation (AF). METHODS AND RESULTS: The single-center prospective observational study investigated consecutive patients who underwent initial left atrial ablation for symptomatic paroxysmal (PAF) or persistent AF (persAF). Age groups (A-F) of less than 40, 40-49, 50-59, 60-69, 70-79 and more than or equal to 80 years were evaluated. Follow-up (FU) included ECG, Holter monitoring and assessment of AF-symptoms. From 2012 to 2016, a total of 786 patients (64 ± 11 years, range 21-85) underwent CBA. With advancing age, more cardiovascular comorbidities and larger LA diameter were observed, more females were included (each p < .001). PAF (57%) and persAF (43%, p = .320) were equally distributed over all age groups. Age was neither related to procedural parameters, nor to the complication rate (3.9%, p = .233). Median FU was 38 months. Two non-procedure related noncardiac deaths occurred late during FU. Freedom from arrhythmia was independent of age at 18 months (p = .210) but decreased for patients more than or equal to 70 years at 24 months (p = .02). At 36 months, freedom from arrhythmia was 66%-74% (groups A-D), 54% (E) and 49% (F), respectively (p = .002). LA diameter and persAF were independent predictors, whereas age was a dependent predictor of recurrence. CONCLUSION: CBA as the primary approach in the initial ablation procedure is safe and highly effective in the young, middle aged, and elderly population. LA diameter and persAF, but not ageing, were independent predictors for arrhythmia recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Lactente , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
4.
J Thorac Imaging ; 36(6): 345-352, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32205821

RESUMO

OBJECTIVES: Computed tomography (CT) myocardial perfusion imaging (CT-MPI) with hyperemia induced by regadenoson was evaluated for the detection of myocardial ischemia, safety, relative radiation exposure, and patient experience compared with single-photon emission computed tomography (SPECT) imaging. MATERIALS AND METHODS: Twenty-four patients (66.5 y, 29% male) who had undergone clinically indicated SPECT imaging and provided written informed consent were included in this phase II, IRB-approved, and FDA-approved clinical trial. All patients underwent coronary CT angiography and CT-MPI with hyperemia induced by the intravenous administration of regadenoson (0.4 mg/5 mL). Patient experience and findings on CT-MPI images were compared to SPECT imaging. RESULTS: Patient experience and safety were similar between CT-MPI and SPECT procedures and no serious adverse events due to the administration of regadenoson occurred. SPECT resulted in a higher number of mild adverse events than CT-MPI. Patient radiation exposure was similar during the combined coronary computed tomography angiography and CT-MPI (4.4 [2.7] mSv) and SPECT imaging (5.6 [1.7] mSv) (P-value 0.401) procedures. Using SPECT as the reference standard, CT-MPI analysis showed a sensitivity of 58.3% (95% confidence interval [CI]: 27.7-84.8), a specificity of 100% (95% CI: 73.5-100), and an accuracy of 79.1% (95% CI: 57.9-92.87). Low apparent sensitivity occurred when the SPECT defects were small and highly suspicious for artifacts. CONCLUSIONS: This study demonstrated that CT-MPI is safe, well tolerated, and can be performed with comparable radiation exposure to SPECT. CT-MPI has the benefit of providing both complete anatomic coronary evaluation and assessment of myocardial perfusion.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Angiografia Coronária , Estudos de Viabilidade , Feminino , Humanos , Masculino , Purinas , Pirazóis , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
5.
J Thorac Imaging ; 36(1): 52-56, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32251233

RESUMO

BACKGROUND: Invasive coronary angiography (ICA) still causes a significant amount of radiation exposure for patients and operators. In February 2017, the Azurion system was introduced, a new-generation fluoroscopy image acquisition and processing system. Radiation exposure in patients undergoing ICA was assessed comparing the novel Azurion 7 F12 angiography system to its predecessor Allura Xper in a randomized manner. METHODS: Radiation exposure was prospectively analyzed in 238 patients undergoing diagnostic ICA. Patients were randomly assigned to the novel Azurion system (119 patients) or its predecessor Allura Xper system (119 patients). In each patient, 8 predefined standard projections (5 left coronary artery, 3 right coronary artery) were performed. Image quality was quantified by grading of the images on the basis of a 5-point grading system. RESULTS: Radiation dose area product was significantly lower in the Azurion group 109 (interquartile range [IQR 75-176] cGy cm) compared with the Allura Xper group 208 [IQR 134-301] cGy cm (P<0.001). Body mass index (26.6 [IQR 23.9-29.7] kg/m vs. 26.2 [IQR 24.2-29.4] kg/m; P=0.607), body surface area (1.96 [IQR 1.81-2.11] m vs. 1.90 [IQR 1.77-20.4] m; P=0.092), and procedure duration (1.5 [IQR 1.2-2.3] min vs. 1.6 [IQR 1.2-2.5] min; P=0.419) were similar in both groups. Images from the Azurion system were at least of equal quality compared with Allura Xper (image quality grade 4.82±0.45 vs. 4.75±0.52, P=0.43). CONCLUSION: Use of the novel Azurion 7 F12 angiography system resulted in a significant reduction of dose area product in patients undergoing diagnostic ICA by 56%.


Assuntos
Redução da Medicação , Exposição à Radiação , Angiografia Coronária , Fluoroscopia , Humanos , Doses de Radiação
6.
Circ Cardiovasc Interv ; 13(6): e008649, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32527192

RESUMO

BACKGROUND: Even among biomarker-negative patients undergoing elective percutaneous coronary intervention (PCI), periprocedural thrombotic and bleeding complications can lead to increased morbidity and mortality. Whether stronger platelet inhibition by an intensified oral loading strategy (ILS) before PCI impacts on outcomes among these patients in contemporary practice remains unclear. METHODS: This multicenter, randomized, assessor-blinded trial tested the hypothesis that in elective PCI prasugrel 60 mg (ILS) is superior to standard loading strategy with clopidogrel 600 mg regarding a composite primary end point of all-cause death, any myocardial infarction, definite/probable stent thrombosis, stroke, or urgent vessel revascularization. After PCI, all patients were on clopidogrel 75 mg/day and aspirin. The trial was terminated prematurely because of slower-than-expected recruitment and funding discontinuation. RESULTS: Of 781 patients included in the final analysis, 382 were assigned to ILS and 399 to standard loading strategy. At 30 days, the primary end point occurred in 66 patients (17.3%) assigned to ILS and 74 patients (18.6%) assigned to standard loading strategy (odds ratio, 0.92 [95% CI, 0.63-1.32]; P=0.64). Any myocardial infarction and Bleeding Academic Research Consortium ≥2 bleeding rates were similar among ILS and standard loading strategy groups 16.2% versus 17.5%, odds ratio, 0.91 (95% CI, 0.62-1.32), P=0.62 and 4.2% versus 4.8%, odds ratio 0.87 (95% CI, 0.44-1.73), P=0.70, respectively. CONCLUSIONS: In biomarker-negative stable and unstable angina patients undergoing elective PCI, the trial did not find a conclusive difference in efficacy or safety. This observation should be interpreted in the context of wide CIs and premature termination of the trial. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02548611.


Assuntos
Clopidogrel/administração & dosagem , Trombose Coronária/prevenção & controle , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/administração & dosagem , Cloridrato de Prasugrel/administração & dosagem , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Administração Oral , Idoso , Clopidogrel/efeitos adversos , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Esquema de Medicação , Término Precoce de Ensaios Clínicos , Feminino , Hemorragia/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Cloridrato de Prasugrel/efeitos adversos , Estudos Prospectivos , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Recidiva , Medição de Risco , Fatores de Risco , Stents , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Resultado do Tratamento
7.
J Cardiovasc Comput Tomogr ; 14(1): 36-41, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31327744

RESUMO

BACKGROUND: To investigate the impact of left ventricular outflow tract (LVOT) calcification on the incidence of device failure and mortality in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: Of 690 consecutive patients undergoing transfemoral TAVI in our center from January 2013 to December 2015, 600 presented with non-severe (NSCALVOT) and 90 (13.0%) with severe (SCALVOT) LVOT calcification. Primary outcome of interest was device failure defined as a composite of procedural death, prosthesis dislocation, annulus rupture or significant para-valvular leakage (PVL). Secondary outcome of interest was 30-day and one-year all-cause mortality. RESULTS: Mean age of the population was 80.8 ±â€¯7.2 years, mean STS score was 5.7 ±â€¯4.6% and 50.6% of the patients were women. Patients with SCALVOT more frequently experienced device failure (10.0% vs. 3.8%, p = 0.009) and were at higher risk of 30 day (10.0% vs. 2.8%, p < 0.001) all cause mortality as compared to those with NSCALVOT. Furthermore, patients with SCALVOT were more frequently in need of post-dilation (15.6% vs. 8.5%, p = 0.032) and showed higher incidence of significant PVL (7.8% vs. 2.5%, p = 0.007). In multivariate analysis, SCALVOT (hazard ratio 2.87; 95% CI 1.20 to 6.34) and use of balloon-expandable prosthesis (hazard ratio 0.32; 95% CI 0.15 to 0.73) were identified as independent predictors of device failure. CONCLUSION: Presence of severe LVOT calcification in patients undergoing transfemoral TAVI is associated with a higher risk of device failure and short-term mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Bases de Dados Factuais , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Tomografia Computadorizada Multidetectores , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
8.
J Thorac Imaging ; 35(3): 167-172, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31373946

RESUMO

OBJECTIVES: Cryoballoon pulmonary vein isolation (cPVI) in patients with atrial fibrillation requires fluoroscopic guidance, causing a relevant amount of radiation exposure. Strategies to reduce radiation exposure in electrophysiologic procedures and specifically cPVI are of great importance. The aim of this study was to evaluate a possible reduction of radiation dose using the novel Azurion 7 F12 x-ray system compared with its predecessor Allura FD10. METHODS: In February 2017, the Philips Azurion angiography system was introduced, combining the Allura Clarity radiation dose reduction technology with a more powerful generator, improved image resolution, and a large screen display. In 173 patients undergoing cPVI by a single experienced operator in our institution between December 2016 and April 2018, dose area products (cGy×cm) and image quality were compared using Azurion 7 F12 or Allura FD10 angiography system. RESULTS: A significant reduction in total radiation dose expressed as a dose area products of 524 (332; 821) cGy×cm on the Allura system compared with 309 (224; 432) cGy×cm on the Azurion system was observed (P<0.001). The number of imaging scenes recorded were 14.7 versus 13.9, and mean overall imaging quality scores (grading 4.85±0.4 with Azurion vs. 4.80±0.4 with Allura, P=0.38) and scores based on specific quality parameters were similar in both groups. CONCLUSION: Use of the new Azurion 7 F12 angiography system substantially reduced radiation doses compared with the previous generation reference system, Allura Clarity, without compromising imaging quality in patients undergoing cryoballoon pulmonary vein isolation.


Assuntos
Angiografia/métodos , Criocirurgia/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Doses de Radiação , Radiografia Intervencionista/métodos , Idoso , Feminino , Humanos , Masculino , Resultado do Tratamento
9.
Radiology ; 293(2): 260-271, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31502938

RESUMO

In this article, the authors discuss the technical background and summarize the current body of literature regarding virtual monoenergetic (VM) images derived from dual-energy CT data, which can be reconstructed between 40 and 200 keV. Substantially improved iodine attenuation at lower kiloelectron volt levels and reduced beam-hardening artifacts at higher kiloelectron volt levels have been demonstrated from all major manufacturers of dual-energy CT units. Improved contrast attenuation with VM imaging at lower kiloelectron volt levels enables better delineation and diagnostic accuracy in the detection of various vascular or oncologic abnormalities. Low-kiloelectron-volt VM imaging may be useful for salvaging CT studies with suboptimal contrast material delivery or providing additional information on the arterial vasculature obtained from venous phase acquisitions. For patients with renal impairment, substantial reductions in the use of iodinated contrast material can be achieved by using lower-energy VM imaging. The authors recommend routine reconstruction of VM images at 50 keV when using dual-energy CT to exploit the increased contrast properties. For reduction of beam-hardening artifacts, VM imaging at 120 keV is useful for the initial assessment.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Doenças Cardiovasculares/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Humanos , Neoplasias/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
10.
J Thorac Imaging ; 34(5): 338-344, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30801452

RESUMO

OBJECTIVES: Left ventricular (LV) hypertrophy in resistant hypertensive patients is associated with a reduced intramyocardial perfusion. Renal sympathetic denervation (RDN) has been shown to reduce blood pressure (BP) and sympathetic tone. We aimed to prospectively investigate the effect of RDN on functional myocardial parameters and myocardial perfusion reserve (MPR) using cardiac magnetic resonance imaging (cMRI) in patients with resistant hypertension. METHODS: A total of 15 resistant hypertensive patients (11 male individuals, mean age 62±13 y) were included. Adenosine stress-induced cMRI was performed at baseline, 3, 6, and 12 months after RDN. RDN was performed using a single soft-tip radiofrequency catheter (Symplicity). cMRI semiquantitative perfusion analysis was performed using the upslope of myocardial signal enhancement to derive the myocardial perfusion reserve index. RESULTS: Both systolic-BP and diastolic-BP significantly decreased from 148±14 to 133±14 mm Hg and 87±14 to 80±10 mm Hg, respectively (P<0.05). LV septal wall thickness was significantly reduced (P<0.001). LV ejection fraction and MPR lacked significant trends 12 months after RDN. CONCLUSIONS: In this pilot study, RDN significantly reduced LV mass and LV septal wall thickness, as diagnosed by cMRI, with no significant changes in MPR. cMRI may help in diagnosing clinically relevant changes of functional myocardial parameters after interventional therapy in resistant hypertensive patients.


Assuntos
Coração/diagnóstico por imagem , Hipertensão/complicações , Hipertrofia Ventricular Esquerda/complicações , Hipertrofia Ventricular Esquerda/cirurgia , Imageamento por Ressonância Magnética/métodos , Simpatectomia/métodos , Feminino , Seguimentos , Coração/fisiopatologia , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Hipertensão/fisiopatologia , Hipertrofia Ventricular Esquerda/patologia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Projetos Piloto , Estudos Prospectivos , Artéria Renal , Resultado do Tratamento
12.
Expert Rev Cardiovasc Ther ; 16(6): 441-453, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29734858

RESUMO

INTRODUCTION: Computed tomographic (CT) coronary artery calcium scoring (CAC) has been validated as a well-established screening method for cardiovascular risk stratification and treatment management that is used in addition to traditional risk factors. The purpose of this review is to present an update on current and future applications of CAC. Areas covered: The topic of CAC is summarized from its introduction to current application with focus on the validation and clinical integration including cardiovascular risk prediction and outcome, cost-effectiveness, impact on downstream medical testing, and the technical advances in scanner and software technology that are shaping the future of CAC. Furthermore, this review aims to provide guidance for the appropriate clinical use of CAC. Expert commentary: CAC is a well-established screening test in preventive care that is underused in daily clinical practice. The widespread clinical implementation of CAC will be decided by future technical advances in CT image acquisition, cost-effectiveness, and reimbursement status.


Assuntos
Cálcio/metabolismo , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Vasos Coronários/patologia , Análise Custo-Benefício , Humanos , Medição de Risco/métodos , Fatores de Risco
13.
Eur Radiol ; 28(7): 3097-3104, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29404770

RESUMO

OBJECTIVES: To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition. METHODS: 78 patients (58% male, 61.5±9.1 years) were prospectively enrolled. Subjects underwent clinical 120kVp high-pitch CACS using third-generation dual-source CT followed by additional high-pitch Sn100kVp acquisition. Agatston scores, calcium volume scores, Agatston score categories, percentile-based risk categorization and radiation metrics were compared. RESULTS: 61/78 patients showed coronary calcifications. Median Agatston scores were 34.9 [0.7-197.1] and 41.7 [0.7-207.2] and calcium volume scores were 34.1 [0.7-218.0] for Sn100kVp and 35.7 [1.1-221.0] for 120kVp acquisitions, respectively (both p<0.0001). Bland-Altman analysis revealed underestimated Agatston scores and calcium volume scores with Sn100kVp versus 120kVp acquisitions (mean difference: 16.4 and 11.5). However, Agatston score categories and percentile-based risk categories showed excellent agreement (ĸ=0.98 and ĸ=0.99). Image noise was 25.8±4.4HU and 16.6±2.9HU in Sn100kVp and 120kVp scans, respectively (p<0.0001). Dose-length-product was 9.9±4.8mGy*cm and 40.9±14.4mGy*cm with Sn100kVp and 120kVp scans, respectively (p<0.0001). This resulted in significant effective radiation dose reduction (0.13±0.07mSv vs. 0.57±0.2mSv, p<0.0001) for Sn100kVp acquisitions. CONCLUSION: CACS using high-pitch low-voltage tin-filtered acquisitions demonstrates excellent agreement in Agatston score and percentile-based cardiac risk categorization with standard 120kVp high-pitch acquisitions. Furthermore, radiation dose was significantly reduced by 78% while maintaining accurate risk prediction. KEY POINTS: • Coronary artery calcium scoring with tin filtration reduces radiation dose by 78%. • There is excellent correlation between high-pitch Sn100kVp and standard 120kVp acquisitions. • Excellent agreement regarding Agatston score categories and percentile-based risk categorization was achieved. • No cardiac risk reclassifications were observed using Sn100kVp coronary artery calcium scoring.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cálcio , Feminino , Filtração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Estanho
14.
Eur J Radiol ; 91: 29-34, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28629567

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of CT coronary artery calcium scoring (CACS) with tin pre-filtration (Sn100kVp) using iterative beam-hardening correction (IBHC) calcium material reconstruction compared to the standard 120kVp acquisition. BACKGROUND: Third generation dual-source CT (DSCT) CACS with Sn100kVp acquisition allows significant dose reduction. However, the Sn100kVp spectrum is harder with lower contrast compared to 120kVp, resulting in lower calcium score values. Sn100kVp spectral correction using IBHC-based calcium material reconstruction may restore comparable calcium values. METHODS: Image data of 62 patients (56% male, age 63.9±9.2years) who underwent a clinically-indicated CACS acquisition using the standard 120kVp protocol and an additional Sn100kVp CACS scan as part of a research study were retrospectively analyzed. Datasets of the Sn100kVp scans were reconstructed using a dedicated spectral IBHC CACS reconstruction to restore the spectral response of 120kVp spectra. Agatston scores were derived from 120kVp and IBHC reconstructed Sn100kVp studies. Pearson's correlation coefficient was assessed and Agatston score categories and percentile-based risk categorization were compared. RESULTS: Median Agatston scores derived from IBHC Sn100kVp scans and 120kVp acquisition were 31.7 and 34.1, respectively (p=0.057). Pearson's correlation coefficient showed excellent correlation between the acquisitions (r=0.99, p<0.0001). Agatston score categories and percentile-based cardiac risk categories showed excellent agreement (ĸ=1.00 and ĸ=0.99), resulting in a low cardiac risk reclassification of 1.6% with the use of IBHC CACS reconstruction. Image noise was 24.9±3.6HU in IBHC Sn100kVp and 17.1±3.9HU in 120kVp scans (p<0.0001). The dose-length-product was 13.2±3.4mGycm with IBHC Sn100kVp and 59.1±22.9mGycm with 120kVp scans (p<0.0001), resulting in a significantly lower effective radiation dose (0.19±0.07mSv vs. 0.83±0.33mSv, p<0.0001) for IBHC Sn100kVp scans. CONCLUSION: Low voltage CACS with tin filtration using a dedicated IBHC CACS material reconstruction algorithm shows excellent correlation and agreement with the standard 120kVp acquisition regarding Agatston score and cardiac risk categorization, while radiation dose is significantly reduced by 75% to the level of a chest x-ray.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Cálcio , Feminino , Filtração , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Estanho
15.
J Cardiovasc Comput Tomogr ; 11(1): 16-24, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28111212

RESUMO

BACKGROUND: There is no published data on the prognostic value of global myocardial perfusion values at stress dynamic CT myocardial perfusion imaging (CTMPI). METHODS: Data of 144 patients from 6 centers who had undergone coronary CT angiography (coronary CTA) and CTMPI were assessed. Coronary CTA studies were acquired at rest; CTMPI was performed under vasodilator stress. Coronary CTA data were evaluated for coronary artery stenosis (≥50% luminal narrowing) on a per-vessel basis. Volumes-of-interest were placed over the entire left ventricular myocardium to obtain global myocardial blood flow (MBF), myocardial blood volume (MBV), and volume transfer constant (Ktrans). Follow-up was obtained at 6/12/18 months. Major adverse cardiac events (MACE, defined as cardiac death, non-fatal myocardial infarction, unstable angina requiring hospitalization, and revascularization) served as the endpoint. RESULTS: MACE occurred in 40 patients (nonfatal myocardial infarction, n = 1, unstable angina, n = 13, PCI, n = 23, and CABG, n = 3). Patients with global MBF of <121 mL/100 mL/min were at increased risk for MACE (HR 2.07, 95% confidence interval [CI]: 1.12-3.84, p = 0.02). This association remained significant after adjusting for age, gender, and clinical risk factors (HR 2.17, 95%CI: 1.16-4.06, p = 0.02), after further adjusting for presence of ≥50% stenosis at coronary CTA (HR 2.18, 95%CI: 1.16-4.10, p = 0.02) and when excluding early (<6 months) revascularizations (HR 2.34, 95%CI: 1.01-5.43, p = 0.0486). Global MBV and Ktrans were not independent predictors of MACE. CONCLUSION: Global quantification of left ventricular MBF at stress dynamic CTMPI may have incremental predictive value for future MACE over clinical risk factors and assessment of stenosis at coronary CTA.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Estenose Coronária/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Idoso , Angina Instável/mortalidade , Angina Instável/fisiopatologia , Angina Instável/terapia , Ásia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Estenose Coronária/mortalidade , Estenose Coronária/fisiopatologia , Estenose Coronária/terapia , Europa (Continente) , Feminino , Hospitalização , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Revascularização Miocárdica , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Estados Unidos
16.
Eur J Radiol ; 86: 276-283, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28027760

RESUMO

PURPOSE: To assess image quality and accuracy of CT angiography (CTA) for transcatheter aortic valve replacement (TAVR) planning performed with 3rd generation dual-source CT (DSCT). MATERIAL AND METHODS: We evaluated 125 patients who underwent TAVR-planning CTA on 3rd generation DSCT. A two-part protocol was performed including retrospectively ECG-gated coronary CTA (CCTA) and prospectively ECG-triggered aortoiliac CTA using 60mL of contrast medium. Automated tube voltage selection and advanced iterative reconstruction were applied. Effective dose (ED), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Five-point scales were used for subjective image quality analysis. In patients who underwent TAVR, sizing parameters were obtained. RESULTS: Image quality was rated good to excellent in 97.6% of CCTA and 100% of aortoiliac CTAs. CTA studies at >100kV showed decreased objective image quality compared to 70-100kV (SNR, all p≤0.0459; CNR, all p≤0.0462). Mean ED increased continuously from 70 to >100kV (CCTA: 4.5±1.7mSv-13.6±2.9mSv, all p≤0.0233; aortoiliac CTA: 2.4±0.9mSv-6.8±2.7mSv, all p≤0.0414). In 39 patients TAVR was performed and annulus diameter was within the recommended range in all patients. No severe cardiac or vascular complications were noted. CONCLUSION: 3rd generation DSCT provides diagnostic image quality in TAVR-planning CTA and facilitates reliable assessment of TAVR device and delivery option while reducing radiation dose.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Algoritmos , Estenose da Valva Aórtica/cirurgia , Meios de Contraste , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos
17.
Am J Cardiol ; 119(4): 675-680, 2017 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-27986261

RESUMO

This study prospectively investigated the accuracy and radiation dose reduction of CT coronary artery calcium scoring (CACS) using a 100 kVp acquisition protocol with tin filtration (Sn100 kVp) compared with the standard 120 kVp acquisition protocol; 70 patients (59% men, 62.1 ± 10.7 years) who underwent a clinically indicated CACS acquisition using the standard 120 kVp protocol on a third-generation dual-source CT system were enrolled. An additional Sn100 kVp CACS scan was performed. Agatston scores and categories, percentile-based risk categorization, and radiation dose estimates were derived from 120 and Sn100 kVp studies and compared. Median Agatston scores from the Sn100 and 120 kVp acquisitions were 38.2 and 41.2, respectively (p <0.0001). Excellent correlation of Agatston scores was found between the 2 acquisitions (r = 0.99, p <0.0001). Although the Agatston scores were systematically lower with Sn100 than with 120 kVp, the comparison of Agatston score categories and percentile-based cardiac risk categories showed excellent agreement (κ = 0.98 and κ = 0.98). Image noise was 26.3 ± 5.7 Hounsfield units in Sn100 kVp and 17.6 ± 4.1 Hounsfield units in 120 kVP scans (p <0.0001). The dose-length product was 14.1 ± 3.7 mGy·cm with Sn100 kVp and 58.5 ± 23.5 mGy·cm with 120 kVp scans (p <0.0001), resulting in a significantly lower effective radiation dose (0.19 ± 0.05 vs 0.82 ± 0.32 mSv, p <0.0001) for Sn100 kVp scans. CACS using a low-voltage tin filtration protocol shows excellent correlation and agreement with the standard method with regard to the Agatston score and subsequent cardiac risk categorization, while achieving a 75% reduction in radiation dose.


Assuntos
Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Doses de Radiação , Estanho , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
18.
J Cardiovasc Comput Tomogr ; 10(4): 301-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27255411

RESUMO

BACKGROUND: To identify patients with early signs of myocardial perfusion reduction, a reference base for perfusion measures is needed. OBJECTIVE: To analyze perfusion parameters derived from dynamic computed tomography perfusion imaging (CTPI) in patients with suspected coronary artery disease (CAD), and relationship with risk factors. METHODS: In this multicenter study, coronary CT angiography (cCTA) and dynamic CTPI were performed by second-generation dual-source CT in patients suspected of CAD. Risk factors were collected from hospital records. Patients with visual perfusion defects on CTPI, previous coronary intervention, or missing risk factor details were excluded. This analysis included 98 patients (mean age ± standard deviation [SD], 59.0 ± 8.6yrs; 73 male). Global measures of left ventricular myocardial blood flow (MBF), myocardial blood volume (MBV) and volume transfer constant (K(trans)) were calculated. RESULTS: Mean MBF was 139.3 ± 31.4 mL/100 mL/min, MBV 19.1 ± 2.7 mL/100 mL, and Ktrans 85.0 ± 17.5 mL/100 mL/min. No significant differences in perfusion parameters were found by gender or age category. Hypertension and diabetes mellitus resulted in lower perfusion parameters (hypertension vs normotension: MBV 18.5 ± 3.0 vs 19.7 ± 2.3 mL/100 mL and K(trans) 82.0 ± 18.0 vs 89.0 ± 16.0, p < 0.05; diabetes vs no diabetes: MBF 128.5 ± 31.5 vs 144.0 ± 30.5 mL/100 mL/min and MBV 17.9 ± 2.4 vs 19.4 ± 2.8 mL/100 mL, p < 0.05). In patients with hyperlipidemia, MBF was higher (146.8 ± 34.4 vs 130.7 ± 24.3 mL/100 mL/min, p < 0.05). Smoking and family history did not show perfusion parameter differences. CONCLUSIONS: Dynamic CTPI identifies early perfusion disturbances in conditions like diabetes and hypertension. With further standardization, absolute perfusion measures may improve CAD risk stratification in patients without visual perfusion defects.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Angiopatias Diabéticas/diagnóstico por imagem , Hipertensão/complicações , Imagem de Perfusão do Miocárdio/métodos , Idoso , Ásia , Velocidade do Fluxo Sanguíneo , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Angiopatias Diabéticas/etiologia , Angiopatias Diabéticas/fisiopatologia , Diagnóstico Precoce , Europa (Continente) , Feminino , Humanos , Hipertensão/diagnóstico , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA