Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Clin Res Cardiol ; 113(1): 68-74, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37294310

RESUMO

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic stenosis in patients with intermediate to prohibitive surgical risk. When a single TAVI device fails and cannot be retrieved, TAVI-in-TAVI must be performed acutely, but outcomes of bailout TAVI-in-TAVI have been incompletely appraised. We aimed at analyzing patient, procedural and outcome features of patients undergoing bailout TAVI-in-TAVI in a multicenter registry. METHODS: Details of patients undergoing bailout TAVI-in-TAVI, performed acutely or within 24 h of index TAVI, in 6 international high-volume institutions, were collected. For every case provided, 2 same-week consecutive controls (prior TAVI, and subsequent TAVI) were provided. Outcomes of interest were procedural and long-term events, including death, myocardial infarction, stroke, access site complication, major bleeding, and reintervention, and their composite (i.e. major adverse events [MAE]). RESULTS: A total of 106 patients undergoing bailout TAVI-in-TAVI were included, as well as 212 controls, for a total of 318 individuals. Bailout TAVI-in-TAVI was less common in younger patients, those with higher body mass index, or treated with Portico/Navitor or Sapien devices (all p < 0.05). Bailout TAVI-in-TAVI was associated with higher in-hospital rates of death, emergency surgery, MAE, and permanent pacemaker implantation (all p < 0.05). Long-term follow-up showed that bailout TAVI-in-TAVI was associated with higher rates of death and MAE (both < 0.05). Similar findings were obtained at adjusted analyses (all p < 0.05). However, censoring early events, outlook was not significantly different when comparing the two groups (p = 0.897 for death, and p = 0.645 for MAE). CONCLUSIONS: Bail-out TAVI-in-TAVI is associated with significant early and long-term mortality and morbidity. Thus, meticulous preprocedural planning and sophisticated intraprocedural techniques are of paramount importance to avoid these emergency procedures.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia , Sistema de Registros , Valva Aórtica/cirurgia , Fatores de Risco
2.
Eur Heart J Qual Care Clin Outcomes ; 9(5): 529-536, 2023 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-36195332

RESUMO

AIMS: Standardized data definitions are necessary for the quantification of quality of care and patient outcomes in observational studies and randomised controlled trials (RCTs). The European Unified Registries for Heart Care Evaluation and Randomised Trials (EuroHeart) project of the European Society of Cardiology (ESC) aims to create pan-European data standards for cardiovascular diseases and interventions, including transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: We followed the EuroHeart methodology for cardiovascular data standard development. A Working Group of 29 members representing 12 countries was established and included a patient representative, as well as experts in the management of valvular heart disease from the European Association of Percutaneous Cardiovascular Interventions (EAPCI), the European Association of Cardiovascular Imaging (EACVI) and the Working Group on Cardiovascular Surgery. We conducted a systematic review of the literature and used a modified Delphi method to reach consensus on a final set of variables. For each variable, the Working Group provided a definition, permissible values, and categorized the variable as mandatory (Level 1) or additional (Level 2) based on its clinical importance and feasibility. In total, 93 Level 1 and 113 Level 2 variables were selected, with the level 1 variables providing the dataset for registration of patients undergoing TAVI on the EuroHeart IT platform. CONCLUSION: This document provides details of the EuroHeart data standards for TAVI processes of care and in-hospital outcomes. In the context of EuroHeart, this will facilitate quality improvement, observational research, registry-based RCTs and post-marketing surveillance of devices, and pharmacotherapies. ONE-SENTENCE SUMMARY: The EuroHeart data standards for transcatheter aortic valve implantation (TAVI) are a set of internationally agreed data variables and definitions that once implemented will facilitate improvement of quality of care and outcomes for patients receiving TAVI.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Sistema de Registros , Ensaios Clínicos Controlados Aleatórios como Assunto
3.
Can J Cardiol ; 38(9): 1418-1425, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35842172

RESUMO

BACKGROUND: Outcomes after transcatheter aortic valve replacement (TAVR) and infectious diseases may vary according to sex. METHODS: This multicentre study aimed to determine the sex differences in clinical characteristics, management, and outcomes of infective endocarditis (IE) after TAVR. A total of 579 patients (217 women, 37.5%) who had the diagnosis of definite IE following TAVR were included retrospectively from the Infectious Endocarditis After TAVR International Registry. RESULTS: Women were older (80 ± 8 vs 78 ± 8 years; P = 0.001) and exhibited a lower comorbidity burden. Clinical characteristics and microbiological profiles were similar between men and women, but culture-negative IE was more frequent in women (9.9% vs 4.3%; P = 0.009). A high proportion of patients had a clinical indication for surgery (54.4% in both groups; P = 0.99), but a surgical intervention was performed in a minority of patients (women 15.2%, men 20.3%; P = 0.13). The mortality rate at index IE hospitalisation was similar in both groups (women 35.4%, men 31.7%; P = 0.37), but women exhibited a higher mortality rate at 2-year follow-up (63% vs 52.1%; P = 0.021). Female sex remained an independent risk factor for cumulative mortality in the multivariable analysis (adjusted HR 1.28, 95% CI 1.02-1.62; P = 0.035). After adjustment for in-hospital events, surgery was not associated with better outcomes in women. CONCLUSIONS: There were no significant sex-related differences in the clinical characteristics and management of IE after TAVR. However, female sex was associated with increased 2-year mortality risk.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Endocardite/diagnóstico , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Caracteres Sexuais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Clin Res Cardiol ; 111(10): 1087-1097, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35262756

RESUMO

BACKGROUND: Scarce data exist about early infective endocarditis (IE) after trans-catheter aortic valve replacement (TAVR). OBJECTIVE: The objective was to evaluate the characteristics, management, and outcomes of very early (VE) IE (≤ 30 days) after TAVR. METHODS: This multicenter study included a total of 579 patients from the Infectious Endocarditis after TAVR International Registry who had the diagnosis of definite IE following TAVR. RESULTS: Ninety-one patients (15.7%) had VE-IE. Factors associated with VE-IE (vs. delayed IE (D-IE)) were female gender (p = 0.047), the use of self-expanding valves (p < 0.001), stroke (p = 0.019), and sepsis (p < 0.001) after TAVR. Staphylococcus aureus was the main pathogen among VE-IE patients (35.2% vs. 22.7% in the D-IE group, p = 0.012), and 31.2% of Staphylococcus aureus infections in the VE-IE group were methicillin-resistant (vs. 14.3% in the D-IE group, p = 0.001). The second-most common germ was enterococci (34.1% vs. 24.4% in D-IE cases, p = 0.05). VE-IE was associated with very high in-hospital (44%) and 1-year (54%) mortality rates. Acute renal failure following TAVR (p = 0.001) and the presence of a non-enterococci pathogen (p < 0.001) were associated with an increased risk of death. CONCLUSION: A significant proportion of IE episodes following TAVR occurs within a few weeks following the procedure and are associated with dismal outcomes. Some baseline and TAVR procedural factors were associated with VE-IE, and Staphylococcus aureus and enterococci were the main causative pathogens. These results may help to select the more appropriate antibiotic prophylaxis in TAVR procedures and guide the initial antibiotic therapy in those cases with a clinical suspicion of IE. Very early infective endocarditis after trans-catheter aortic valve replacement. VE-IE indicates very early infective endocarditis (≤30 days post TAVR). D-IE indicates delayed infective endocarditis.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Estafilocócicas , Substituição da Valva Aórtica Transcateter , Antibacterianos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Endocardite/etiologia , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Masculino , Fatores de Risco , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/epidemiologia , Infecções Estafilocócicas/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
5.
J Am Coll Cardiol ; 79(8): 772-785, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35210032

RESUMO

BACKGROUND: The optimal treatment of patients developing infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) is uncertain. OBJECTIVES: The goal of this study was to investigate the clinical characteristics and outcomes of patients with TAVI-IE treated with cardiac surgery and antibiotics (IE-CS) compared with patients treated with antibiotics alone (IE-AB). METHODS: Crude and inverse probability of treatment weighting analyses were applied for the treatment effect of cardiac surgery vs medical therapy on 1-year all-cause mortality in patients with definite TAVI-IE. The study used data from the Infectious Endocarditis after TAVI International Registry. RESULTS: Among 584 patients, 111 patients (19%) were treated with IE-CS and 473 patients (81%) with IE-AB. Compared with IE-AB, IE-CS was not associated with a lower in-hospital mortality (HRunadj: 0.85; 95% CI: 0.58-1.25) and 1-year all-cause mortality (HRunadj: 0.88; 95% CI: 0.64-1.22) in the crude cohort. After adjusting for selection and immortal time bias, IE-CS compared with IE-AB was also not associated with lower mortality rates for in-hospital mortality (HRadj: 0.92; 95% CI: 0.80-1.05) and 1-year all-cause mortality (HRadj: 0.95; 95% CI: 0.84-1.07). Results remained similar when patients with and without TAVI prosthesis involvement were analyzed separately. Predictors for in-hospital and 1-year all-cause mortality included logistic EuroSCORE I, Staphylococcus aureus, acute renal failure, persistent bacteremia, and septic shock. CONCLUSIONS: In this registry, the majority of patients with TAVI-IE were treated with antibiotics alone. Cardiac surgery was not associated with an improved all-cause in-hospital or 1-year mortality. The high mortality of patients with TAVI-IE was strongly linked to patients' characteristics, pathogen, and IE-related complications.


Assuntos
Endocardite Bacteriana/tratamento farmacológico , Endocardite Bacteriana/cirurgia , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/cirurgia , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Procedimentos Cirúrgicos Cardíacos , Terapia Combinada , Endocardite Bacteriana/etiologia , Feminino , Humanos , Masculino , Infecções Relacionadas à Prótese/etiologia , Infecções Estafilocócicas/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
6.
J Am Coll Cardiol ; 79(6): 562-573, 2022 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-35144748

RESUMO

BACKGROUND: Risk stratification for transcatheter edge-to-edge mitral valve repair (TEER) is paramount in the decision-making process for treating severe mitral regurgitation (MR). OBJECTIVES: This study sought to create and validate a user-friendly score (MitraScore) to predict the risk of mortality in patients undergoing TEER. METHODS: The derivation cohort was based on a multicentric international registry that included 1,119 patients referred for TEER between 2012 and 2020. Score discrimination was assessed using Harrell's c-statistic, and the calibration was evaluated with the Gronnesby and Borgan goodness-of-fit test. An external validation was carried out in 725 patients from the GIOTTO registry. RESULTS: After multivariate analysis, we identified 8 independent predictors of mortality during the follow-up (2.1 ± 1.8 years): age ≥75 years, anemia, glomerular filtrate rate <60 mL/min/1.73 m2, left ventricular ejection fraction <40%, peripheral artery disease, chronic obstructive pulmonary disease, high diuretic dose, and no therapy with renin-angiotensin system inhibitors. The MitraScore was derived by assigning 1 point to each independent predictor. The c-statistic was 0.70. Per each point of the MitraScore, the relative risk of mortality increased by 55% (HR: 1.55; 95% CI: 1.44-1.67; P < 0.001). The discrimination and calibration for mortality prediction was better than those of EuroSCORE II (c-statistic 0.61) or Society of Thoracic Surgeons score (c-statistic 0.57). The MitraScore maintained adequate performance in the validation cohort (c-statistic 0.66). The score was also predictive for heart failure rehospitalization and was correlated with the probability of clinical improvement. CONCLUSIONS: The MitraScore is a simple prediction algorithm for the prediction of follow-up mortality in patients treated with TEER.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/mortalidade , Sistema de Registros , Idoso , Feminino , Seguimentos , Humanos , Itália/epidemiologia , Masculino , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico/fisiologia , Fatores de Tempo , Resultado do Tratamento
7.
PLoS One ; 17(1): e0260770, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34995276

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) is used increasingly for revascularization of unprotected left main coronary artery (LMCA) disease. Observational studies and subgroup analyses from clinical trials, have suggested a possible benefit from the use of intravascular ultrasound (IVUS) guidance when performing unprotected LMCA PCI. However, the value of imaging with IVUS has never been proven in an appropriately powered randomized clinical trial. The OPtimizaTIon of Left MAin PCI With IntravascuLar Ultrasound (OPTIMAL) trial has been designed to establish whether IVUS-guided PCI optimization on LMCA is associated with superior clinical outcomes when compared with standard qualitative angiography-guided PCI. METHODS: The OPTIMAL trial is a randomized, multicenter, international study designed to enroll a total of 800 patients undergoing PCI for unprotected LMCA disease. Patients will be randomized in a 1:1 fashion to IVUS-guided PCI versus angiogram-guided PCI. In patients allocated to the angiogram-guided arm, use of IVUS is discouraged, unless there are safety concerns. In patients allocated to the IVUS guidance arm, pre-procedural IVUS assessment is highly recommended, whilst post-procedural IVUS assessment is mandatory to confirm appropriate stenting result and/or to guide stent result optimization, according to predefined criteria. Patients will be followed up to 2 years after the index procedure. The primary outcome measure is the Academic Research Consortium (ARC) patient-oriented composite endpoint (PoCE) which includes all-cause death, any stroke, any myocardial infarction and any repeat revascularization at 2 years follow-up. DISCUSSION: The OPTIMAL trial aims to provide definitive evidence about the clinical impact of IVUS-guidance during PCI to an unprotected LMCA. It is anticipated by the investigators, that an IVUS-guided strategy will be associated with less clinical events compared to a strategy guided by angiogram alone. TRIAL REGISTRATION: ClinicalTrials.gov: NCT04111770. Registered on October 1, 2019.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Intervenção Coronária Percutânea/métodos , Ultrassonografia de Intervenção/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/etiologia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Cirurgia Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Ultrassonografia/métodos
8.
Can J Cardiol ; 38(1): 102-112, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34688853

RESUMO

BACKGROUND: Staphylococcus aureus (SA) has been extensively studied as causative microorganism of surgical prosthetic-valve infective endocarditis (IE). However, scarce evidence exists on SA IE after transcatheter aortic valve replacement (TAVR). METHODS: Data were obtained from the Infectious Endocarditis After TAVR International Registry, including patients with definite IE after TAVR from 59 centres in 11 countries. Patients were divided into 2 groups according to microbiologic etiology: non-SA IE vs SA IE. RESULTS: SA IE was identified in 141 patients out of 573 (24.6%), methicillin-sensitive SA in most cases (115/141, 81.6%). Self-expanding valves were more common than balloon-expandable valves in patients presenting with early SA IE. Major bleeding and sepsis complicating TAVR, neurologic symptoms or systemic embolism at admission, and IE with cardiac device involvement (other than the TAVR prosthesis) were associated with SA IE (P < 0.05 for all). Among patients with IE after TAVR, the likelihood of SA IE increased from 19% in the absence of those risk factors to 84.6% if ≥ 3 risk factors were present. In-hospital (47.8% vs 26.9%; P < 0.001) and 2-year (71.5% vs 49.6%; P < 0.001) mortality rates were higher among patients with SA IE vs non-SA IE. Surgery at the time of index SA IE episode was associated with lower mortality at follow-up compared with medical therapy alone (adjusted hazard ratio 0.46, 95% CI 0.22-0.96; P = 0.038). CONCLUSIONS: SA IE represented approximately 25% of IE cases after TAVR and was associated with very high in-hospital and late mortality. The presence of some features determined a higher likelihood of SA IE and could help to orientate early antibiotic regimen selection. Surgery at index SA IE was associated with improved outcomes, and its role should be evaluated in future studies.


Assuntos
Endocardite Bacteriana/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Sistema de Registros , Infecções Estafilocócicas/epidemiologia , Staphylococcus aureus/isolamento & purificação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Endocardite Bacteriana/microbiologia , Feminino , Seguimentos , Saúde Global , Próteses Valvulares Cardíacas/microbiologia , Mortalidade Hospitalar/tendências , Humanos , Incidência , Masculino , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Fatores de Risco , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Taxa de Sobrevida/tendências , Substituição da Valva Aórtica Transcateter/efeitos adversos
9.
Cardiovasc Revasc Med ; 40: 180-188, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34906439

RESUMO

Tricuspid regurgitation (TR) is frequently detected, especially in its secondary form, while primary TR is far less frequent. Similar to mitral regurgitation (MR), primary tricuspid regurgitation should require timely intervention to avoid secondary damage of the RV, which is associated with poor outcome. Current guidelines suggest that secondary TR should be treated at the time of left-sided valve surgery, although a surgical option is rarely offered to high-risk patients with combined heart valve disease. As such, while the transcatheter approach to mitral valve repair/replacement has become a major goal of the transcatheter therapies, the transcatheter tricuspid valve intervention is still at a very early stage. In this review, we provide an overview of the different stages of technical and clinical evolution of transcatheter treatment of patients with TR or MR, highlighting the challenges and the avenues for future research.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/cirurgia
10.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-34894124

RESUMO

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Assuntos
Falso Aneurisma , Endocardite Bacteriana , Endocardite , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Abscesso , Falso Aneurisma/complicações , Falso Aneurisma/cirurgia , Coagulase , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Humanos , Insuficiência Renal Crônica/complicações , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos
11.
G Ital Cardiol (Rome) ; 22(9 Suppl 1): 21S-28S, 2021 09.
Artigo em Italiano | MEDLINE | ID: mdl-34590621

RESUMO

Transcatheter aortic valve implantation (TAVI) has become an established alternative to surgery in patients with calcific aortic stenosis. Broad implementation of devices and increased experience have led operators to explore the feasibility of TAVI in off-label indication such as pure native aortic valve regurgitation. Given the technical issues related to the absence of leaflet calcification and aortic root or ascending aorta dilation, this procedure is typically performed in patients in whom surgical risk is deemed prohibitive. Although recently published data have shown encouraging results in patients treated with new generation prostheses, new iteration of transcatheter valves, specifically designed for the treatment of aortic regurgitation, is needed. Nowadays, with no dedicated system on the horizon and in order to guarantee the best results, efforts should be made to improve patient selection.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
12.
J Invasive Cardiol ; 33(5): E320-E329, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33739300

RESUMO

OBJECTIVES: The management of severe aortic stenosis has been revolutionized by the introduction of transcatheter aortic valve implantation (TAVI), especially in patients at intermediate, high, or prohibitive surgical risk. There is uncertainty, however, regarding the comparative effectiveness and safety of contemporary TAVI devices. METHODS: We queried detailed data from the ongoing national Italian TAVI registry and compared baseline features, procedural details, and 12-month outcomes of Acurate Neo (Boston Scientific), Evolut Pro/R (Medtronic), Lotus (Boston Scientific), Portico (Abbott Vascular), and Sapien/ Sapien S3 Ultra (Edward Lifesciences) transcatheter aortic valves. Several endpoints were collected and appraised, including the composite of death, stroke, myocardial infarction (MI), major bleeding, major vascular complication, surgical aortic valve replacement and transcatheter aortic valve reimplantation, which were deemed major adverse events (MAEs). RESULTS: A total of 1976 patients were included, with 234 treated with Acurate, 703 with Evolut, 151 with Lotus, 347 with Portico, and 541 with Sapien. Twelve-month events were not significantly different among the 5 devices, including death (P=.29) and MAE (P=.21), with the notable exception of major vascular complications, which were more common with Acurate and Sapien (P<.001) and permanent pacemaker implantation, which was more frequent with Lotus and Evolut (P<.001). Differences in MAE were more pronounced in women and subjects with prior cardiac surgery, with the lowest event rates in the Evolut group. Propensity-score adjusted analysis suggested that Acurate, Evolut, Portico, and Sapien were all associated with similarly favorable results, whereas adverse events were more evident with Lotus (P<.05). CONCLUSION: Leading current-generation TAVI devices offer similarly favorable results at mid-term follow-up.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Infarto do Miocárdio , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Feminino , Coração , Humanos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Pontuação de Propensão , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
Front Cardiovasc Med ; 8: 585415, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33614745

RESUMO

Secondary mitral regurgitation (MR) occurs despite structurally normal valve apparatus due to an underlying disease of the myocardium leading to disruption of the balance between tethering and closing forces with ensuing failure of leaflet coaptation. In patients with heart failure (HF) and left ventricular dysfunction, secondary MR is independently associated with poor outcome, yet prognostic benefits related to the correction of MR have remained elusive. Surgery is not recommended for the correction of secondary MR outside coronary artery bypass grafting. Percutaneous mitral valve repair (PMVR) with MitraClip implantation has recently evolved as a new transcatheter treatment option of inoperable or high-risk patients with severe MR, with promising results supporting the extension of guideline recommendations. MitraClip is highly effective in reducing secondary MR in HF patients. However, the derived clinical benefit is still controversial as two randomized trials directly comparing PMVR vs. optimal medical therapy in severe secondary MR yielded virtually opposite conclusions. We reviewed current evidence to identify predictors of PMVR-related outcomes in secondary MR useful to improve the timing and the selection of patients who would derive maximal benefit from MitraClip intervention. Beyond mitral valve anatomy, optimal candidate selection should rely on a comprehensive diagnostic workup and a fine-tuned risk stratification process aimed at (i) recognizing the substantial heterogeneity of secondary MR and its complex interaction with the myocardium, (ii) foreseeing hemodynamic consequences of PMVR, (iii) anticipating futility and (iv) improving symptoms, quality of life and overall survival.

14.
Circulation ; 143(2): 104-116, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-32975133

RESUMO

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/normas , Valva Mitral/cirurgia , Sistema de Registros , Reoperação/normas , Substituição da Valva Aórtica Transcateter/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Reoperação/tendências , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/tendências
15.
Interact Cardiovasc Thorac Surg ; 32(1): 20-28, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33201993

RESUMO

OBJECTIVES: To compare device success and paravalvular leak rates of 3 new-generation transcatheter aortic valve replacement devices in patients with bicuspid aortic valve stenosis and to test their biomechanical performance in a computer-based simulation model of aortic root with increasing ellipticity. METHODS: This retrospective multicentre study included 56 bicuspid aortic valve patients undergoing transcatheter aortic valve replacement with new-generation devices: Lotus/Lotus Edge (N = 15; 27%), Evolut-R (N = 20; 36%) and ACURATE neo (N = 21; 37%). Three virtual simulation models of aortic root with increasing index of eccentricity (0-0.25-0.5) were implemented. Stress distribution, stent-root contact area and paravalvular orifice area were computed. RESULTS: Device success was achieved in 43/56 patients (77%) with comparable rates among Lotus (87%), Evolut-R (60%) and ACURATE neo (86%; P = 0.085). Moderate paravalvular leak rate was significantly lower in the Lotus group as compared to Evolut-R group (0% vs 30%; P = 0.027) and comparable to the ACURATE neo group (0% vs 10%; P = 0.33). By index of eccentricity = 0.5, Lotus showed a uniform and symmetric pattern of stress distribution with absent paravalvular orifice area, ACURATE neo showed a mild asymmetry with small paravalvular orifice area (1.1 mm2), whereas a severely asymmetric pattern was evident with Evolut-R, resulting in a large paravalvular orifice area (12.0 mm2). CONCLUSIONS: Transcatheter aortic valve replacement in bicuspid aortic valve patients with new-generation devices showed comparable device success rates. Lotus showed moderate paravalvular leak rate comparable to that of ACURATE neo and significantly lower than Evolut-R. On simulation, Lotus and ACURATE neo showed optimal adaptability to elliptic anatomies as compared to Evolut-R.


Assuntos
Doença da Válvula Aórtica Bicúspide/cirurgia , Constrição Patológica/cirurgia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Aorta/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Humanos , Masculino , Estudos Retrospectivos , Stents , Resultado do Tratamento
16.
J Invasive Cardiol ; 32(2): 58-63, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32005785

RESUMO

OBJECTIVES: To assess the incidence of no-reflow in patients undergoing chronic total occlusion (CTO) percutaneous coronary intervention (PCI), analyze possible causes and differential diagnoses, and identify useful management approaches. METHODS: In this multicenter observational study, all CTO-PCIs performed between January 2018 and April 2019 were reviewed to collect no-reflow complications, defined as Thrombolysis in Myocardial Infarction (TIMI) flow ≤1 in a patent epicardial artery. Patient clinical, anatomical, and procedural characteristics were analyzed. RESULTS: Out of 461 PCIs, two (0.43%) were complicated by no-reflow. In 1 case, PCI was performed on a long segment of the right coronary artery, after use of a dissection-re-entry technique by knuckle wiring. In the second patient, no-reflow developed after proximal left anterior descending coronary artery stenting, with a short subintimal tracking. Intravascular ultrasound was used to exclude complications in the epicardial vessel in both cases. Distal embolization seems the most plausible cause, and intracoronary adenosine effectively improved flow. Both patients had a type 4a myocardial infarction, asymptomatic in the first case, and associated with chest pain, electrocardiographic changes, and new regional wall-motion abnormality at echocardiography in the second case. CONCLUSIONS: No-reflow in CTO recanalization is rare, but associated with a high risk of periprocedural myocardial infarction, with incomplete protection from ischemia offered by the pre-existing collateral network.


Assuntos
Adenosina/uso terapêutico , Circulação Coronária/efeitos dos fármacos , Oclusão Coronária , Infarto do Miocárdio , Fenômeno de não Refluxo , Intervenção Coronária Percutânea , Complicações Pós-Operatórias , Angiografia Coronária/métodos , Oclusão Coronária/diagnóstico , Oclusão Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Vasos Coronários/cirurgia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/terapia , Fenômeno de não Refluxo/diagnóstico , Fenômeno de não Refluxo/etiologia , Fenômeno de não Refluxo/terapia , Avaliação de Processos e Resultados em Cuidados de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/terapia , Ultrassonografia de Intervenção/métodos , Vasodilatadores/uso terapêutico
17.
Circ Cardiovasc Interv ; 12(11): e007938, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31694412

RESUMO

BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Endocardite Bacteriana/epidemiologia , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Tomada de Decisão Clínica , Remoção de Dispositivo , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/cirurgia , Feminino , Humanos , Incidência , Masculino , Seleção de Pacientes , Desenho de Prótese , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Sistema de Registros , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
Cardiovasc Revasc Med ; 20(5): 371-375, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30857975

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a well-established treatment option for severe aortic stenosis (AS). AS and coronary artery disease frequently coincide, and therefore some patients may require coronary angiography (CAG) and/or intervention (PCI) post-TAVR. Due to valve stent design, most self-expanding prostheses always cover the coronary ostium, and therefore may hinder future access. The objective of this research was to evaluate the incidence, safety and feasibility of CAG/PCI in patients with prior self-expanding TAVR valves. METHODS: Among 2170 patients (age 82 ±â€¯6 years, 43% male) who underwent TAVR with Corevalve or Evolut prostheses, as part of the Italian CoreValve ClinicalService® framework (data from 13 Italian centers), the occurrence of CAG/PCI following TAVR and periprocedural characteristics were examined. RESULTS: During median follow-up of 379 days, 41 patients (1.9%) required CAG and/or PCI (total 46; 16 CAG, 14 PCI, 16 both PCI/CAG). 56.5% of the procedures were performed under emergency/urgency settings. Left system coronary angiography was successfully performed in most cases (28/32, 87.5%), while right coronary angiography was successful only in 50.0% (16/32). PCI procedures (20 for left system, 3 for right system, 4 for graft) were successfully performed in 93.3% (28/30) of the procedures. No CAG/PCI procedure-related complications including prosthesis dislodgment or coronary ostium dissection occurred. CONCLUSIONS: CAG and PCI procedures following CoreValve TAVR is safe and mostly feasible, although the success rate of selective right coronary angiography was relatively low when compared to the left system. Further investigations are required to explore this issue.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Angiografia Coronária/efeitos adversos , Ponte de Artéria Coronária , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/terapia , Bases de Dados Factuais , Estudos de Viabilidade , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Cardiovasc Revasc Med ; 20(12): 1096-1099, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30711476

RESUMO

BACKGROUND: Significant aortic stenosis can be effectively treated with transcatheter aortic valve implantation (TAVI) in patients at high or intermediate surgical risk. Predilation is often performed to facilitate TAVI implantation, but its risk-benefit balance with new-generation devices is detabed. We aimed to appraise whether predilation is still needed with new-generation devices for TAVI. METHODS/MATERIALS: We queried the prospective multicenter RISPEVA (Registro Italiano GISE sull'impianto di Valvola Aortica Percutanea) Study, comparing patients with vs without predilation receiving Acurate, Evolut, Lotus, Portico, or Sapien3. Baseline, procedural features and early clinical and echocardiographic results were compared with unadjusted and adjusted analyses. RESULTS: A total of 1409 subjects were included, 1055 (74.9%) receiving predilation, and 354 (25.1%) undergoing direct TAVI. Several baseline and procedural differences were evident at unadjusted analysis between the two groups, including device success, procedural success, contrast volume, procedural time, mean post-procedural gradient, and prevalence of aortic regurgitation 2+ (all p < 0.05). Adjusted analysis showed that only procedural time remained significantly impacted by predilation (average reduction in procedural time with predilation of -12.9 [95% confidence interval -21.0; -4.8] minutes, p = 0.002). Subgroup unadjusted and adjusted analysis showed that predilation was associated with shorter procedural times only when Evolut or Portico devices were used (all p < 0.05). Clinical and echocardiographic follow-up up to 1 month showed similar results irrespective of predilation at both unadjusted and adjusted analysis. CONCLUSION: TAVI without predilation is not associated with adverse procedural, clinical or echocardiographic results when new-generation devices are used. Predilation may however reduce procedural time with Evolut and Portico devices.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Ecocardiografia , Feminino , Humanos , Itália , Masculino , Duração da Cirurgia , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
J Invasive Cardiol ; 30(10): 380-385, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30279294

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) is an effective treatment for severe aortic stenosis. Yet, balloon aortic valvuloplasty (BAV) is still occasionally offered to apparently inoperable patients as bridge or destination therapy, with some eventually receiving TAVI. We aimed to determine whether prior BAV would unfavorably impact TAVI. METHODS: The RISPEVA dataset was analyzed to compare the outcomes of non-BAV subjects undergoing TAVI vs those with prior BAV. Outcomes of interest were procedural results, hospital stay, and in-hospital outcomes, including major adverse events. Unadjusted and propensity-matched analyses were performed. RESULTS: A total of 1683 patients were included (1541 [91.6%] non-BAV and 142 [8.4%] prior BAV). Device success, procedural success, major adverse events and their individual components were all similar in the two groups, in both unadjusted and propensity-matched analyses. However, non-BAV patients had significantly shorter intensive/coronary care unit stay (8.1 ± 23.0 days vs 13.4 ± 35.2 days; P=.03) and total hospital stay (12.4 ± 22.1 days vs 17.2 ± 32.7 days; P=.02). Similar findings were obtained even in the propensity-matched groups (6.3 ± 11.9 days vs 13.6 ± 35.5 days [P=.05] and 10.5 ± 13.8 days vs 17.4 ± 33.1 days [P=.03], respectively). No significant interaction was found between device type and prior BAV status. CONCLUSION: BAV continues to offer a palliative solution to patients with unclear or poor prognosis and deemed at too high risk for emergent TAVI or surgery. Subjects undergoing BAV and surviving the post-BAV period can undergo TAVI without a significantly increased risk of in-hospital adverse events in comparison with non-BAV patients.


Assuntos
Angioplastia com Balão/métodos , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Feminino , Seguimentos , Humanos , Tempo de Internação/tendências , Masculino , Prognóstico , Estudos Prospectivos , Reoperação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA