Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Respirology ; 27(10): 890-899, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35598093

RESUMO

BACKGROUND AND OBJECTIVE: Upper airway surgery for obstructive sleep apnoea (OSA) is an alternative treatment for patients who are intolerant of continuous positive airway pressure (CPAP). However, upper airway surgery has variable treatment efficacy with no reliable predictors of response. While we now know that there are several endotypes contributing to OSA (i.e., upper airway collapsibility, airway muscle response/compensation, respiratory arousal threshold and loop gain), no study to date has examined: (i) how upper airway surgery affects all four OSA endotypes, (ii) whether knowledge of baseline OSA endotypes predicts response to surgery and (iii) whether there are any differences when OSA endotypes are measured using the CPAP dial-down or clinical polysomnographic (PSG) methods. METHODS: We prospectively studied 23 OSA patients before and ≥3 months after multilevel upper airway surgery. Participants underwent clinical and research PSG to measure OSA severity (apnoea-hypopnoea index [AHI]) and endotypes (measured in supine non-rapid eye movement [NREM]). Values are presented as mean ± SD or median (interquartile range). RESULTS: Surgery reduced the AHITotal (38.7 [23.4 to 79.2] vs. 22.0 [13.3 to 53.5] events/h; p = 0.009). There were no significant changes in OSA endotypes, however, large but variable improvements in collapsibility were observed (CPAP dial-down method: ∆1.9 ± 4.9 L/min, p = 0.09, n = 21; PSG method: ∆3.4 [-2.8 to 49.0]%Veupnoea , p = 0.06, n = 20). Improvement in collapsibility strongly correlated with improvement in AHI (%∆AHISupineNREM vs. ∆collapsibility: p < 0.005; R2  = 0.46-0.48). None of the baseline OSA endotypes predicted response to surgery. CONCLUSION: Surgery unpredictably alters upper airway collapsibility but does not alter the non-anatomical endotypes. There are no baseline predictors of response to surgery.


Assuntos
Apneia Obstrutiva do Sono , Nível de Alerta/fisiologia , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Sistema Respiratório/cirurgia , Resultado do Tratamento
2.
Ann Am Thorac Soc ; 17(4): 484-491, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31821768

RESUMO

Rationale: Unstable ventilatory control (high loop gain) is a causal factor in the development of obstructive sleep apnea. Methods for quantifying loop gain using polysomnography have been developed that predict favorable responses to upper airway surgery. However, this method is reliant on respiratory event scoring and hence may be affected by hypopnea scoring criteria.Objectives: To determine to what extent differences in hypopnea scoring influence loop gain measurement.Methods: We performed a retrospective analysis of 46 polysomnograms before and after upper airway surgery. Polysomnograms were rescored according to three different American Academy of Sleep Medicine hypopnea definitions (2007Alternative, 2012Recommended, and 2012Acceptable criteria). Loop gain and apnea-hypopnea indexes (AHIs) were compared between criteria using linear regression and Bland-Altman limits of agreement (LOA). Responders to surgery were classified by a 50% or greater reduction in AHI and AHIpostsurgery less than 10 events per hour. Responders were determined separately for each American Academy of Sleep Medicine criterion. Receiver operating characteristic curve analysis predicting surgical outcome was performed for each loop gain measurement derived from each criterion.Results: A near-perfect agreement was found between loop gains derived using the 2007Alternative and 2012Recommended criteria (r2 = 0.99; bias = -0.003; LOA, -0.016 to 0.010). Greater variability was found for 2012Acceptable compared to the 2007Alternative (r2 = 0.70; bias = -0.015; LOA, -0.099 to 0.070) and 2012Recommended (r2 = 0.69; bias = +0.018; LOA, -0.068 to 0.104) criteria. Both 2007Alternative and 2012Recommended loop gains significantly predicted surgical response with similar areas under the curve (AUCs; 2007Alternative AUC = 0.86 [95% confidence interval (CI), 0.75-0.97]; 2012Recommended AUC = 0.84 [95% CI, 0.71-0.97]). 2012Acceptable loop gains were a poor predictor of surgical response (AUC = 0.62 [95% CI, 0.43-0.80]).Conclusions: Loop gain measured noninvasively by polysomnography can be influenced by respiratory event scoring. We recommend caution when using the 2012Acceptable criteria with this method, because such findings may not be directly generalizable to other loop gain values derived from other scoring criteria.


Assuntos
Polissonografia/normas , Apneia Obstrutiva do Sono/diagnóstico , Adulto , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Polissonografia/métodos , Guias de Prática Clínica como Assunto , Estudos Retrospectivos , Apneia Obstrutiva do Sono/fisiopatologia , Sociedades Médicas , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA