Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 221
Filtrar
1.
Kyobu Geka ; 77(3): 217-221, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465495

RESUMO

A 51-year-old man visited to our hospital because of chest discomfort and hematemesis. He was diagnosed with Mallory-Weiss syndrome and followed in outpatient clinic. One week later, he visited our hospital again for fever and discomfort. Chest computed tomography (CT) showed a foreign body perforated in the mediastinum in the upper esophagus, and he was urgently hospitalized for surgical removal of esophageal foreign body. Before surgery he vomited the esophageal foreign body with a lot of blood. Hematemesis was stopped spontaneously and contrast-enhanced CT revealed a pseudoaneurysm in the distal aortic arch, so thoracic endovascular aortic repair (TEVAR) was performed to prevent rupture. Esophageal endoscopy found that the site of esophageal injury healed spontaneously, so the patient was followed conservatively with antibiotics. He was discharged on postoperative day 18 uneventfully. TEVAR was an effective treatment for aortic injury caused by esophageal foreign body in our case.


Assuntos
Doenças da Aorta , Procedimentos Endovasculares , Corpos Estranhos , Masculino , Humanos , Pessoa de Meia-Idade , Hematemese/complicações , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Doenças da Aorta/cirurgia , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia
2.
ASAIO J ; 69(12): 1056-1064, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37549664

RESUMO

Few studies have focused on the clinical outcomes and risk factors of left ventricular assist device (LVAD) pump infection, and no standard treatment for LVAD pump infection has been established. Therefore, we used a therapeutic flowchart to manage LVAD pump infections. We retrospectively evaluated 220 patients who underwent continuous-flow LVAD implantation between January 2005 and March 2021 at Osaka University, Japan. First, we performed wound debridement, negative-pressure wound therapy, antibiotic treatment, and omental flap transposition. Subsequently, we administered conservative treatment, scheduled implantable LVAD exchange, or emergent removal of the implantable LVAD and exchange for extracorporeal LVAD or percutaneous LVAD (IMPELLA). Pump infections occurred in 32 patients. The survival rates of patients with pump infections during LVAD support were 93%, 74%, and 61% at 180 days, 1 year, and 2 years after LVAD pump infection, respectively. Fifteen patients underwent successful heart transplantation. Bridge-to-bridge surgery, preoperative use of venoarterial extracorporeal membrane oxygenation or percutaneous LVAD, high lactate dehydrogenase levels, and driveline infection were significantly associated with pump infection. Our study reveals that poor preoperative condition and driveline infection were significant risk factors for LVAD pump infection.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Insuficiência Cardíaca/cirurgia , Estudos Retrospectivos , Coração Auxiliar/efeitos adversos , Resultado do Tratamento
3.
J Artif Organs ; 2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37468735

RESUMO

During continuous-flow left ventricular assist device (CF-LVAD) support, hemodynamic shear stress causes a burden on aortic valve (AV) leaflets, leading to de novo aortic insufficiency (AI). This study investigated the influence of preoperative hemodynamic parameters on de novo AI in CF-LVAD recipients. We reviewed 125 patients who underwent CF-LVAD implantation without concomitant AV surgery between 2005 and 2018. De novo AI was defined as moderate or severe AI in those with none or trivial preoperative AI. During mean 30 ± 16 months of CF-LVAD support, de novo AI-free rate was 86% and 67% at 1 and 2 years, respectively. Multivariable analysis showed that higher right ventricular stroke work index (RVSWI) (hazard ratio, 1.12 /g/m2/beat; 95% confidence interval, 1.00-1.20; p = 0.047) and trivial grade AI (hazard ratio, 2.8; 95% confidence interval, 1.2-6.4; p = 0.020) were independent preoperative risk factors for de novo AI. The longitudinal analysis using generalized mixed effects model showed that higher RVSWI was associated with continuous AV closure after LVAD implantation (Odd ratio, 1.20/g/m2/beat; 95% confidence interval, 1.00-1.43 /g/m2/beat; p = 0.047). Right heart catheterization revealed that preoperative RVSWI was positively correlated with postoperative pump flow index in patients with continuously closed AV (r = 0.44, p = 0.04, n = 22). Preoperative higher RVSWI was a significant risk factor for de novo AI following CF-LVAD implantation. In patients with preserved right ventricular function, postoperative higher pump flow may affect AI development via hemodynamic stress on the AV.

4.
Circ J ; 87(8): 1103-1111, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37258218

RESUMO

BACKGROUND: Recently, destination therapy (DT) was approved in Japan, and patients ineligible for heart transplantation may now receive durable left ventricular assist devices (LVADs). Several conventional risk scores are available, but a risk score that is best to select optimal candidates for DT in the Japanese population remains unestablished.Methods and Results: A total of 1,287 patients who underwent durable LVAD implantation and were listed for the Japanese registry for Mechanically Assisted Circulatory Support (J-MACS) were eligible for inclusion. Finally, 494 patients were assigned to the derivation cohort and 487 patients were assigned to the validation cohort. According to the time-to-event analyses, J-MACS risk scores were newly constructed to predict 3-year mortality rate, consisting of age, history of cardiac surgery, serum creatinine level, and central venous pressure to pulmonary artery wedge pressure ratio >0.71. The J-MACS risk score had the highest predictability of 3-year death compared with other conventional scores in the validation cohort, including HeartMate II risk score and HeartMate 3 risk score. CONCLUSIONS: We constructed the J-MACS risk score to estimate 3-year mortality rate after durable LVAD implantation using large-scale multicenter Japanese data. The clinical utility of this scoring to guide the indication of DT should be validated in the next study.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Dados de Saúde Coletados Rotineiramente , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos
5.
Cell Transplant ; 32: 9636897231154580, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36946544

RESUMO

For ischemic cardiomyopathy (ICM) with limited therapeutic options, the induction of arteriogenesis has the potential to improve cardiac function through major restoration of blood flow. We hypothesized that transplantation of a Notch signaling-modified mesenchymal stem cell (SB623 cell) patch would induce angiogenesis and arteriogenesis in ischemic lesions, leading to improvement of left ventricular (LV) function in a rat ICM model. Two weeks after the induction of ischemia, SB623 cell patch transplantation into ICM rats (SB group, n = 10) or a sham operation (no-treatment group, n = 10) was performed. The LV ejection fraction was significantly improved at 6 weeks after SB623 cell patch transplantation (P < 0.001). Histological findings revealed that the number of von Willebrand factor (vWF)-positive capillary vessels (P < 0.01) and alpha smooth muscle actin (αSMA)- and vWF-positive arterioles with a diameter greater than 20 µm (P = 0.002) was significantly increased in the SB group, suggesting the induction of angiogenesis and arteriogenesis. Moreover, rat cardiomyocytes treated with SB623 cell patch transplantation showed upregulation of ephrin-B2 (P = 0.03) and EphB4 (P = 0.01) gene expression, indicating arteriogenesis induction. In conclusion, SB623 cell patch transplantation improved LV function by inducing angiogenesis and arteriogenesis in a rat ICM model.


Assuntos
Células-Tronco Mesenquimais , Infarto do Miocárdio , Isquemia Miocárdica , Ratos , Animais , Função Ventricular Esquerda , Fator de von Willebrand/metabolismo , Infarto do Miocárdio/terapia , Infarto do Miocárdio/patologia , Isquemia Miocárdica/metabolismo , Isquemia/metabolismo , Células-Tronco Mesenquimais/metabolismo , Neovascularização Fisiológica/fisiologia
6.
Heart Vessels ; 38(7): 949-956, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36773041

RESUMO

Sutureless offers an alternative to standard valves in surgical aortic valve replacement (SAVR). We sought to confirm the efficacy and safety of the Perceval sutureless valve in Japanese patients. Prospective observational study of 204 patients who underwent SAVR with Perceval at 19 sites in Japan between March and December 2019. The primary outcomes were 30-day mortality and postoperative complications; the secondary outcome was all-cause mortality at 1 year. Efficacy outcomes were changed in New York Heart Association (NYHA) class, pressure gradients, effective orifice area (EOA), EOA indexed to body surface area (EOAi) and severity of aortic regurgitation. Mean age was 77.7 years, 62.7% were female. Procedural success rate was 99.0%. The median cross-clamp and cardiopulmonary bypass times were 68.0 and 108 min. Perceval size S and M were implanted in 95 (46.6%) and in 76 (37.3%) of patients, respectively. The 30-day and late mortality rate were 0.5% and 4.4%, while the new permanent pacemaker implantation rate was 4.4%. Mean pressure gradient was 13.0 mmHg at discharge, reaching 11.0 mmHg at 1 year; while the mean EOA was 1.5 cm2 at discharge remaining stable up to 1 year. No moderate or severe leakages were present at discharge or at 1 year. NYHA class improved by ≥ 1 level in 55.1% of the patients at discharge and in 69.4% of the patients at 1 year. 1-year outcomes of SAVR with the Perceval sutureless valve in Japanese patients were favorable. This valve offers a promising alternative to conventional biological AVR in this Japanese population.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos sem Sutura , Humanos , Feminino , Idoso , Masculino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , População do Leste Asiático , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Vigilância de Produtos Comercializados , Resultado do Tratamento
7.
Cell Transplant ; 32: 9636897221148457, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36624995

RESUMO

Although mesenchymal stem cell transplantation has been successful in the treatment of ischemic cardiomyopathy, the underlying mechanisms remain unclear. Herein, we investigated whether mitochondrial transfer could explain the success of cell therapy in ischemic cardiomyopathy. Mitochondrial transfer in co-cultures of human adipose-derived mesenchymal stem cells and rat cardiomyocytes maintained under hypoxic conditions was examined. Functional recovery was monitored in a rat model of myocardial infarction following human adipose-derived mesenchymal stem cell transplantation. We observed mitochondrial transfer in vitro, which required the formation of cell-to-cell contacts and synergistically enhanced energy metabolism. Rat cardiomyocytes exhibited mitochondrial transfer 3 days following human adipose-derived mesenchymal stem cell transplantation to the ischemic heart surface post-myocardial infarction. We detected donor mitochondrial DNA in the recipient myocardium concomitant with a significant improvement in cardiac function. Mitochondrial transfer is vital for successful cell transplantation therapies and improves treatment outcomes in ischemic cardiomyopathy.


Assuntos
Cardiomiopatias , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais , Infarto do Miocárdio , Ratos , Humanos , Animais , Miocárdio/metabolismo , Infarto do Miocárdio/terapia , Infarto do Miocárdio/genética , Miócitos Cardíacos/metabolismo , Cardiomiopatias/terapia , Transplante de Células-Tronco
8.
J Thorac Cardiovasc Surg ; 165(6): 2026-2033, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-34246489

RESUMO

BACKGROUND: In patients with ischemic mitral regurgitation (MR) undergoing restrictive mitral annuloplasty (RMA), the ratio of left ventricular (LV) end-systolic dimension (LVESD) to mitral valve (MV) ring size (ie, LV-MV ring mismatch) is associated with postoperative recurrent MR. However, the impact of LV-MV ring mismatch on postoperative recurrent MR, LV function recovery, and long-term survival in patients with nonischemic dilated cardiomyopathy (DCM) remains unknown. METHODS: Sixty-six patients with nonischemic DCM (mean LVESD, 62 mm) underwent RMA (mean ring size, 26 mm) between 2003 and 2014. Recurrent MR was defined as MR grade ≥2+ at a 6-month echocardiographic evaluation. RESULTS: At the 6-month follow-up, 23 patients (35%) had developed recurrent MR. In univariable logistic regression analysis, larger LVESD (P = .012) and LVESD/ring size ratio (P = .008) were associated with recurrent MR. In multivariable models adjusted for age, sex, baseline LV ejection fraction, and severe MR, only LVESD/ring size ratio (odds ratio, 4.65; 95% confidence interval, 1.04-25.0; P = .048) remained significantly associated with MR recurrence. Receiver operating characteristic curve analysis demonstrated an optimal cutoff value for the LVESD/ring size ratio of 2.42. Patients with an LVESD/ring size ratio >2.42 (n = 30; mismatch) had a lower 5-year cumulative survival rate compared with those with an LVESD/ring size ratio ≤2.42 (n = 36; nonmismatch) (52% vs 71%; P = .045). Postoperatively, LV dimensions were significantly reduced in both groups; however, improvements in LVEF were only modest in the mismatched group (P = .091). CONCLUSIONS: LV-MV ring size mismatch was associated with an increased risk of recurrent MR in our series. This finding may aid the formulation of surgical strategies for patients with nonischemic DCM.


Assuntos
Cardiomiopatia Dilatada , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/métodos , Seguimentos
9.
J Cardiol ; 81(1): 68-75, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35985870

RESUMO

BACKGROUND: Long-term survival after surgery for severe aortic stenosis (AS) provides important information regarding the choice between surgical (SAVR) and transcatheter (TAVR) aortic valve replacement. This study investigated the long-term survival of AS patients with low or intermediate surgical risk who underwent SAVR or TAVR in our institution versus that of the Japanese general population. METHODS: From 2009 to 2019, 1276 consecutive patients underwent SAVR or TAVR for severe AS. Among them, we retrospectively investigated those with low (n = 383) or intermediate (n = 137) surgical risk treated with SAVR and those with low (n = 86) or intermediate (n = 333) surgical risk treated with TAVR. Their post-intervention survival was compared with that of an age- and gender-matched Japanese general population. RESULTS: The overall 5-year survival rate of SAVR for patients with low surgical risk (mean age, 72 ±â€¯9 years) was not significantly different from that of the general population (90 % vs. 89 %, respectively; p = 0.58), whereas that of patients with intermediate surgical risk (77 ±â€¯6 years) was significantly lower than that of the general population (77 % vs. 84 %, respectively; p = 0.03). After TAVR, the 5-year survival of patients with low (78 ±â€¯8 years) or intermediate (83 ±â€¯5 years) surgical risk was significantly lower than that of the general population (low risk, 64 % vs. 81 %, p < 0.01; intermediate risk, 66 % vs. 71 %, respectively, p = 0.01). CONCLUSIONS: Our study demonstrated that long-term survival after SAVR for AS patients with low surgical risk was as good as that of the age- and gender-matched general population, while the long-term survival after SAVR for intermediate-risk or TAVR for low- or intermediate-risk patients was lower than that of the general population. These findings suggest that SAVR is an appropriate option for AS patients with low surgical risk and good life expectancy, especially in Japan, where the life expectancy is the longest worldwide.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
10.
Front Cardiovasc Med ; 9: 950829, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36051285

RESUMO

Despite major therapeutic advances, heart failure, as a non-communicable disease, remains a life-threatening disorder, with 26 million patients worldwide, causing more deaths than cancer. Therefore, novel strategies for the treatment of heart failure continue to be an important clinical need. Based on preclinical studies, allogenic human induced pluripotent stem cell-derived cardiomyocyte (hiPSC-CM) patches have been proposed as a potential therapeutic candidate for heart failure. We report the implantation of allogeneic hiPSC-CM patches in a patient with ischemic cardiomyopathy (ClinicalTrials.gov, #jRCT2053190081). The patches were produced under clinical-grade conditions and displayed cardiogenic phenotypes and safety in vivo (severe immunodeficient mice) without any genetic mutations in cancer-related genes. The patches were then implanted via thoracotomy into the left ventricle epicardium of the patient under immunosuppressive agents. Positron emission tomography and computed tomography confirmed the potential efficacy and did not detect tumorigenesis in either the heart or other organs. The clinical symptoms improved 6 months after surgery, without any major adverse events, suggesting that the patches were well-tolerated. Furthermore, changes in the wall motion in the transplanted site were recovered, suggesting a favorable prognosis and the potential tolerance to exercise. This study is the first report of a successful transplant of hiPSC-CMs for severe ischemic cardiomyopathy.

11.
Kyobu Geka ; 75(10): 813-818, 2022 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-36155575

RESUMO

Impella is a microaxial blood pump catheter, which could be placed in left ventricle( LV) from peripheral arteries and unload the LV by ejecting the blood from LV to the ascending aorta. It has been used as a less invasive LV assist device in more than 5,000 patients with cardiogenic shock in the last four and a half years since its approval in Japan. The first analysis of Japan Registry for Percutaneous Ventricular Assist Device (J-PVAD) in 819 patients demonstrated that combined use of Impella and veno-arterial extracorporeal membrance oxygenation (VA-ECMO) was applied in 47% and their 30 days survival was worse than single Impella support( 50% vs 81%) due to more profound shock status. Technical advances in less invasive mechanical circulatory support including new Impella 5.5 may play an important role in high-risk cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Catéteres , Coração Auxiliar/efeitos adversos , Humanos , Choque Cardiogênico/cirurgia
12.
Surg Case Rep ; 8(1): 143, 2022 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-35904703

RESUMO

BACKGROUND: Although detachment of the implanted valve prosthesis was a well-known complication in patients with Behçet's disease, complete detachment of an aortic bileaflet valve prosthesis has never been reported. CASE PRESENTATION: An 18-year-old boy with Behçet's disease (HLA-A26 positive) who had previously undergone aortic valve replacement with an 18-mm ATS-Advanced Performance (ATS-AP) valve (ATS Medical, Inc., Minneapolis, MN) at the age of 12 years, presented sudden-onset general fatigue and was emergently transferred to the regional hospital. Chest X-ray showed displacement of the implanted mechanical valve. An echocardiogram revealed mobile valve prosthesis and severe aortic regurgitation. Just before leaving for our hospital for surgical treatment, a completely detached valve prosthesis was floating in the ascending aorta. On arrival, the valve prosthesis was stuck to the transverse arch. Emergent removal of the previous mechanical valve from the aortic arch and redo aortic valve replacement with a 24-mm ATS-AP valve were performed under total circulatory arrest. Infectious endocarditis was denied by histopathological examination. The patient was back to the intensive care unit with extracorporeal membrane oxygenation support, which was successfully decannulated 5 days later. CONCLUSIONS: This was the first report of a patient with Behçet's disease who encountered a complete detachment of implanted aortic valve prosthesis. The patient could be rescued by emergent surgery.

13.
Artigo em Inglês | MEDLINE | ID: mdl-35811142

RESUMO

OBJECTIVES: To elucidate the influence of concomitant restrictive mitral annuloplasty (RMA) on postoperative left ventricular (LV) reverse remodeling and survival in patients with ischemic cardiomyopathy undergoing coronary artery bypass grafting (CABG). METHODS: This study comprised 157 patients with ischemic cardiomyopathy (LV ejection fraction ≤40%) who underwent CABG and completed echocardiographic examination at 1 year after surgery, with 84 (54%) undergoing concomitant RMA for clinically relevant ischemic mitral regurgitation. The primary end point was postoperative reduction in LV end-systolic volume index (LVESVI). The secondary end point was overall survival. Median follow-up was 5.1 years. RESULTS: At baseline, patients who underwent CABG with RMA had a larger LVESVI (83 ± 23 vs 75 ± 24 mm; P = .046). One-year postoperatively, CABG with RMA reduced the LVESVI more than did CABG alone (37% vs 21% from baseline; P < .001), yielding nearly identical postoperative LVESVI (53 ± 27 vs 61 ± 26 mm; P = .065). In multivariable logistic regression analysis, concomitant RMA was associated with significant LV reverse remodeling (odds ratio, 2.79; 95% CI, 1.34-5.78; P = .006). The prevalence in moderate or severe mitral regurgitation was not different between the groups (7% vs 10%; P = .58). Survival rates were similar between the groups (5 years, 78% vs 83%; P = .35). CONCLUSIONS: In patients with ischemic cardiomyopathy undergoing CABG, concomitant RMA was associated with significant reduction in LVESVI. The influence of LV reverse remodeling on survival remains undetermined.

15.
Stem Cell Reports ; 17(5): 1170-1182, 2022 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-35427484

RESUMO

A rotating wall vessel (RWV) bioreactor was constructed for growing massive functional cardiac constructs to recover the function of a distressed rat heart. Three-dimensional cardiac tissues were engineered by seeding human-induced pluripotent stem cell-derived cardiomyocytes on poly(lactic-co-glycolic acid) fiber sheets (3D-hiPSC-CTs) and cultured in the RWV bioreactor (RWV group) or under static conditions (control group). The tissues were transplanted into a myocardial infarction nude rat model, and cardiac performance was evaluated. In the RWV group, cell viability and contractile and electrical properties significantly improved, mature cardiomyocytes were observed, and mechanical stress-related mediators of mammalian target of rapamycin signaling were upregulated compared with those of the control. Four weeks post-transplantation, tissue survival and left ventricular ejection fraction significantly improved in the RWV group. Hence, dynamic culture in an RWV bioreactor could provide a superior culture environment for improved performance of 3D-hiPSC-CTs, providing a means for functional cardiomyogenesis in myocyte-loss heart failure.


Assuntos
Infarto do Miocárdio , Função Ventricular Esquerda , Animais , Reatores Biológicos , Mamíferos , Infarto do Miocárdio/terapia , Miócitos Cardíacos/transplante , Ratos , Ratos Nus , Volume Sistólico , Engenharia Tecidual/métodos
16.
PLoS One ; 17(3): e0264317, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35235568

RESUMO

The loss of functional cells through immunological rejection after transplantation reduces the efficacy of regenerative therapies for cardiac failure that use allogeneic induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs). Recently, mixed-chimera mice with donor-specific immunotolerance have been established using the RGI-2001 (liposomal formulation of α-galactosyl ceramide) ligand, which activates invariant natural killer T (iNKT) cells. The present study aimed to investigate whether mixed chimerism, established using RGI-2001, prolongs graft survival in allogeneic iPSC-CM transplantation. Mixed-chimera mice were established via combinatorial treatment with RGI-2001 and anti-CD154 antibodies in an irradiated murine bone marrow transplant model. Luciferase-expressing allogeneic iPSC-CMs were transplanted into mixed-chimera and untreated mice, followed by in vivo imaging. RGI-2001 enhanced iNKT cell activation in mice, and mixed chimerism was successfully established. In vivo imaging revealed that while the allografts were completely obliterated within 2 weeks when transplanted to untreated mice, their survivals were not affected in the mixed-chimera mice. Furthermore, numerous CD3+ cells infiltrated allografts in untreated mice, but fewer CD3+ cells were present in mixed-chimera mice. We conclude that mixed-chimera mice established using RGI-2001 showed prolonged graft survival after allogeneic iPSC-CM transplantation. This donor-specific immunotolerance might increase the efficacy of regenerative therapies for heart failure with allogeneic iPSC-CMs.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Células-Tronco Pluripotentes Induzidas , Células T Matadoras Naturais , Animais , Transplante de Medula Óssea , Quimera , Quimerismo , Sobrevivência de Enxerto , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Miócitos Cardíacos
17.
Kyobu Geka ; 75(1): 15-20, 2022 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-35249072

RESUMO

In this article, we analyzed 114 adult heart transplantation( HTx) cases from 1999 to 2021. Of these cases, 94% of patients underwent left ventricular assist device ( LVAD) implantation before HTx. The mean period of LVAD support was 3.0 ±1.2 years. Thirty-day mortality was 0.8% and the 10-year survival rate was 89% after HTx. Preoperative and postoperative renal function was the prognostic factors. Long LVAD support was not associated with the long-term survival after HTx.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Adulto , Insuficiência Cardíaca/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Universidades
18.
Ann Thorac Surg ; 113(1): e33-e36, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33794161

RESUMO

Ventricular septal rupture after acute myocardial infarction is a fatal complication with a very high in-hospital mortality. Herein, we describe a new repair technique using a first patch for exclusion of the infarcted myocardium and a second sutureless patch for rupture site closure with a novel tissue adhesive (Hydrofit, Terumo, Tokyo, Japan). Follow-up of over 2 years revealed a good clinical course and no residual interventricular shunt on echocardiography. This modified infarct exclusion technique with a second sutureless patch has a benefit of avoiding stitches to the fragile infarcted myocardium and might be effective in preventing interventricular shunt recurrence after ventricular septal rupture.


Assuntos
Procedimentos Cirúrgicos sem Sutura/métodos , Adesivos Teciduais , Ruptura do Septo Ventricular/terapia , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Humanos , Masculino
19.
J Artif Organs ; 25(2): 110-116, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34581883

RESUMO

Women with implantable left-ventricular assist devices (LVADs) experience gynecological bleeding (GYN-bleeding). However, a few studies have investigated female-specific problems. Therefore, this study aimed to identify the risk factors for adverse GYN-bleeding after LVAD implantation. We retrospectively analyzed 59 women (mean age: 41 ± 15 years) with long-term implantable LVAD support (≥ 6 months) at our institution between 2005 and 2018. The history of GYN-bleeding before implantation was defined as abnormal utero-ovarian bleeding, excessive menstruation, uterine fibroids, and endometrial lesions. GYN-bleeding after implantation was defined as a requirement of emergency outpatient visits and/or hospitalization, blood transfusions, hormonal therapy, and/or surgery. Additionally, risk factors for GYN-bleeding were identified using the Cox regression model. Twenty-four GYN-bleeding cases were seen in 15 patients (two times: five patients, three times: two patients, 0.18 events per patient-year). The 1- and 2-year GYN-bleeding-free rates were 84% and 73%, respectively. Twelve patients (17 events) required RBC ≥ 4 units, and five patients (7 events) required FFP ≥ 4 units. Seven patients required pseudomenopausal treatment after blood transfusion, and four patients required surgical treatment. Fifteen patients with GYN-bleeding after implantation were significantly younger than the remaining 44 patients without GYN-bleeding (34 ± 12 years vs. 43 ± 16 years, P = 0.02). Multivariable risk analysis showed a history of GYN-bleeding before implantation was a significant risk factor (hazard ratio 3.7 [1.2-10.6], P = 0.004). Patients with a history of GYN-bleeding before LVAD implantation have a high risk of developing GYN-bleeding after implantation. We should identify the high-risk population and prepare for the management of GYN-bleeding.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Hemorragia/etiologia , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
20.
Ann Thorac Surg ; 114(1): 115-124, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34534528

RESUMO

BACKGROUND: This study aimed to clarify the incidence and determinants of postoperative adverse events in patients with ischemic cardiomyopathy who achieved long-term durable mitral valve repair. METHODS: Between 1999 and 2015, 166 patients with chronic ischemic mitral regurgitation (MR) and a left ventricular ejection fraction ≤40% underwent restrictive mitral annuloplasty. During follow-up (65 ± 34 months), echocardiographic assessments were performed 809 times (mean, 4.9 ± 2.4 times), and 20 patients who had postoperative recurrent MR (moderate or severe) were excluded. Finally, 146 patients (aged 68 [63-75] years) whose MR was well controlled over time were included. RESULTS: A total of 61 deaths or 27 readmissions for heart failure were observed in 76 patients (52%). Among hospital survivors, age (adjusted hazard ratio, 1.05; P = .001) and estimated glomerular filtration rate (adjusted hazard ratio, 0.61; P = .001) were identified as independent predictors of long-term mortality or readmission for heart failure. The degree of postoperative left ventricular function recovery was comparable between patients with and without adverse events. However, the former group showed greater values for systolic pulmonary artery pressure, tricuspid regurgitation severity, inferior vena cava dimension, and plasma brain natriuretic peptide level throughout the follow-up period (group effect P < .05 for all). CONCLUSIONS: Approximately 50% of patients died or were hospitalized for heart failure even in the absence of recurrent MR during the 5-year follow-up, a finding indicating that durable mitral repair does not always lead to favorable clinical outcomes. The adverse events may have been related to volume overload secondary to impaired renal function and less favorable pulmonary hemodynamics.


Assuntos
Insuficiência Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Insuficiência Cardíaca/etiologia , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA