Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Radiol Artif Intell ; 1(4): e180096, 2019 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-32076660

RESUMO

PURPOSE: To evaluate the use of artificial intelligence (AI) to shorten digital breast tomosynthesis (DBT) reading time while maintaining or improving accuracy. MATERIALS AND METHODS: A deep learning AI system was developed to identify suspicious soft-tissue and calcified lesions in DBT images. A reader study compared the performance of 24 radiologists (13 of whom were breast subspecialists) reading 260 DBT examinations (including 65 cancer cases) both with and without AI. Readings occurred in two sessions separated by at least 4 weeks. Area under the receiver operating characteristic curve (AUC), reading time, sensitivity, specificity, and recall rate were evaluated with statistical methods for multireader, multicase studies. RESULTS: Radiologist performance for the detection of malignant lesions, measured by mean AUC, increased 0.057 with the use of AI (95% confidence interval [CI]: 0.028, 0.087; P < .01), from 0.795 without AI to 0.852 with AI. Reading time decreased 52.7% (95% CI: 41.8%, 61.5%; P < .01), from 64.1 seconds without to 30.4 seconds with AI. Sensitivity increased from 77.0% without AI to 85.0% with AI (8.0%; 95% CI: 2.6%, 13.4%; P < .01), specificity increased from 62.7% without to 69.6% with AI (6.9%; 95% CI: 3.0%, 10.8%; noninferiority P < .01), and recall rate for noncancers decreased from 38.0% without to 30.9% with AI (7.2%; 95% CI: 3.1%, 11.2%; noninferiority P < .01). CONCLUSION: The concurrent use of an accurate DBT AI system was found to improve cancer detection efficacy in a reader study that demonstrated increases in AUC, sensitivity, and specificity and a reduction in recall rate and reading time.© RSNA, 2019See also the commentary by Hsu and Hoyt in this issue.

2.
AJR Am J Roentgenol ; 210(3): 685-694, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29064756

RESUMO

OBJECTIVE: Digital breast tomosynthesis (DBT) is more accurate than full-field digital mammography alone but requires a longer reading time. A radiologist reader study evaluated the use of concurrent computer-aided detection (CAD) to shorten the reading time while maintaining interpretation performance. MATERIALS AND METHODS: A CAD system was developed to detect suspicious soft-tissue densities in DBT planes. Abnormalities are extracted from the plane in which they are detected and blended into the corresponding synthetic image. The study used an enriched sample of 240 DBT cases with 68 malignancies in 61 patients. Twenty radiologists retrospectively reviewed all 240 cases in a multireader multicase crossover design to compare reading time and performance with and without CAD. The performance of CAD alone was also evaluated. RESULTS: Reading time improved by 29.2% with CAD (95% CI, 21.1-36.5%; p < 0.01). Reader performance, measured by ROC AUC, was noninferior with CAD (p < 0.01). The mean AUC increased from 0.841 without to 0.850 with CAD (95% CI, -0.012 to 0.030). Mean sensitivity increased from 0.847 without to 0.871 with CAD (difference 95% CI, -0.005 to 0.055), showing a 0.033 increase in sensitivity for cases with soft-tissue densities (95% CI, -0.002 to 0.068). Mean specificity decreased from 0.527 without to 0.509 with CAD (difference 95% CI, -0.041 to 0.005), and mean recall rate for noncancers slightly increased from 0.474 without to 0.492 with CAD (difference 95% CI, -0.006 to 0.041). CONCLUSION: Concurrent use of CAD with DBT resulted in 29.2% faster reading time, while maintaining reader interpretation performance.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Diagnóstico por Computador/métodos , Mamografia/métodos , Adulto , Idoso , Densidade da Mama , Eficiência , Feminino , França , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Sensibilidade e Especificidade , Fatores de Tempo , Estados Unidos
3.
Eur J Radiol ; 97: 83-89, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29153373

RESUMO

PURPOSE: Evaluate concurrent Computer-Aided Detection (CAD) with Digital Breast Tomosynthesis (DBT) to determine impact on radiologist performance and reading time. MATERIALS AND METHODS: The CAD system detects and extracts suspicious masses, architectural distortions and asymmetries from DBT planes that are blended into corresponding synthetic images to form CAD-enhanced synthetic images. Review of CAD-enhanced images and navigation to corresponding planes to confirm or dismiss potential lesions allows radiologists to more quickly review DBT planes. A retrospective, crossover study with and without CAD was conducted with six radiologists who read an enriched sample of 80 DBT cases including 23 malignant lesions in 21 women. Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) compared the readings with and without CAD to determine the effect of CAD on overall interpretation performance. Sensitivity, specificity, recall rate and reading time were also assessed. Multi-reader, multi-case (MRMC) methods accounting for correlation and requiring correct lesion localization were used to analyze all endpoints. AUCs were based on a 0-100% probability of malignancy (POM) score. Sensitivity and specificity were based on BI-RADS scores, where 3 or higher was positive. RESULTS: Average AUC across readers without CAD was 0.854 (range: 0.785-0.891, 95% confidence interval (CI): 0.769,0.939) and 0.850 (range: 0.746-0.905, 95% CI: 0.751,0.949) with CAD (95% CI for difference: -0.046,0.039), demonstrating non-inferiority of AUC. Average reduction in reading time with CAD was 23.5% (95% CI: 7.0-37.0% improvement), from an average 48.2 (95% CI: 39.1,59.6) seconds without CAD to 39.1 (95% CI: 26.2,54.5) seconds with CAD. Per-patient sensitivity was the same with and without CAD (0.865; 95% CI for difference: -0.070,0.070), and there was a small 0.022 improvement (95% CI for difference: -0.046,0.089) in per-lesion sensitivity from 0.790 without CAD to 0.812 with CAD. A slight reduction in specificity with a -0.014 difference (95% CI for difference: -0.079,0.050) and a small 0.025 increase (95% CI for difference: -0.036,0.087) in recall rate in non-cancer cases were observed with CAD. CONCLUSIONS: Concurrent CAD resulted in faster reading time with non-inferiority of radiologist interpretation performance. Radiologist sensitivity, specificity and recall rate were similar with and without CAD.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Mamografia/normas , Neoplasias da Mama/patologia , Diagnóstico por Computador/métodos , Diagnóstico por Computador/normas , Métodos Epidemiológicos , Feminino , Humanos , Mamografia/métodos , Pessoa de Meia-Idade
4.
Acad Radiol ; 24(7): 876-890, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28262519

RESUMO

RATIONALE AND OBJECTIVES: This study aims to estimate observer performance for a range of dose levels for common computed tomography (CT) examinations (detection of liver metastases or pulmonary nodules, and cause of neurologic deficit) to prioritize noninferior dose levels for further analysis. MATERIALS AND METHODS: Using CT data from 131 examinations (abdominal CT, 44; chest CT, 44; head CT, 43), CT images corresponding to 4%-100% of the routine clinical dose were reconstructed with filtered back projection or iterative reconstruction. Radiologists evaluated CT images, marking specified targets, providing confidence scores, and grading image quality. Noninferiority was assessed using reference standards, reader agreement rules, and jackknife alternative free-response receiver operating characteristic figures of merit. Reader agreement required that a majority of readers at lower dose identify target lesions seen by the majority of readers at routine dose. RESULTS: Reader agreement identified dose levels lower than 50% and 4% to have inadequate performance for detection of hepatic metastases and pulmonary nodules, respectively, but could not exclude any low dose levels for head CT. Estimated differences in jackknife alternative free-response receiver operating characteristic figures of merit between routine and lower dose configurations found that only the lowest dose configurations tested (ie, 30%, 4%, and 10% of routine dose levels for abdominal, chest, and head CT examinations, respectively) did not meet criteria for noninferiority. At lower doses, subjective image quality declined before observer performance. Iterative reconstruction was only beneficial when filtered back projection did not result in noninferior performance. CONCLUSION: Opportunity exists for substantial radiation dose reduction using existing CT technology for common diagnostic tasks.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
5.
AJR Am J Roentgenol ; 204(2): 241-51, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25615744

RESUMO

OBJECTIVE. The purpose of this study was to assess the diagnostic performance of supplemental screening molecular breast imaging (MBI) in women with mammographically dense breasts after system modifications to permit radiation dose reduction. SUBJECTS AND METHODS. A total of 1651 asymptomatic women with mammographically dense breasts on prior mammography underwent screening mammography and adjunct MBI performed with 300-MBq (99m)Tc-sestamibi and a direct-conversion (cadmium zinc telluride) gamma camera, both interpreted independently. The cancer detection rate, sensitivity, specificity, and positive predictive value of biopsies performed (PPV3) were determined. RESULTS. In 1585 participants with a complete reference standard, 21 were diagnosed with cancer: two detected by mammography only, 14 by MBI only, three by both modalities, and two by neither. Of 14 participants with cancers detected only by MBI, 11 had invasive disease (median size, 0.9 cm; range, 0.5-4.1 cm). Nine of 11 (82%) were node negative, and two had bilateral cancers. With the addition of MBI to mammography, the overall cancer detection rate (per 1000 screened) increased from 3.2 to 12.0 (p < 0.001) (supplemental yield 8.8). The invasive cancer detection rate increased from 1.9 to 8.8 (p < 0.001) (supplemental yield 6.9), a relative increase of 363%, while the change in DCIS detection was not statistically significant (from 1.3 to 3.2, p =0.250). For mammography alone, sensitivity was 24%; specificity, 89%; and PPV3, 25%. For the combination, sensitivity was 91% (p < 0.001); specificity, 83% (p < 0.001); and PPV3, 28% (p = 0.70). The recall rate increased from 11.0% with mammography alone to 17.6% (p < 0.001) for the combination; the biopsy rate increased from 1.3% for mammography alone to 4.2% (p < 0.001). CONCLUSION. When added to screening mammography, MBI performed using a radiopharmaceutical activity acceptable for screening (effective dose 2.4 mSv) yielded a supplemental cancer detection rate of 8.8 per 1000 women with mammographically dense breasts.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Imagem Molecular , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação
6.
Med Phys ; 40(8): 081908, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23927322

RESUMO

PURPOSE: The purpose of this study was to investigate the correlation between model observer and human observer performance in CT imaging for the task of lesion detection and localization when the lesion location is uncertain. METHODS: Two cylindrical rods (3-mm and 5-mm diameters) were placed in a 35×26 cm torso-shaped water phantom to simulate lesions with -15 HU contrast at 120 kV. The phantom was scanned 100 times on a 128-slice CT scanner at each of four dose levels (CTDIvol=5.7, 11.4, 17.1, and 22.8 mGy). Regions of interest (ROIs) around each lesion were extracted to generate images with signal-present, with each ROI containing 128×128 pixels. Corresponding ROIs of signal-absent images were generated from images without lesion mimicking rods. The location of the lesion (rod) in each ROI was randomly distributed by moving the ROIs around each lesion. Human observer studies were performed by having three trained observers identify the presence or absence of lesions, indicating the lesion location in each image and scoring confidence for the detection task on a 6-point scale. The same image data were analyzed using a channelized Hotelling model observer (CHO) with Gabor channels. Internal noise was added to the decision variables for the model observer study. Area under the curve (AUC) of ROC and localization ROC (LROC) curves were calculated using a nonparametric approach. The Spearman's rank order correlation between the average performance of the human observers and the model observer performance was calculated for the AUC of both ROC and LROC curves for both the 3- and 5-mm diameter lesions. RESULTS: In both ROC and LROC analyses, AUC values for the model observer agreed well with the average values across the three human observers. The Spearman's rank order correlation values for both ROC and LROC analyses for both the 3- and 5-mm diameter lesions were all 1.0, indicating perfect rank ordering agreement of the figures of merit (AUC) between the average performance of the human observers and the model observer performance. CONCLUSIONS: In CT imaging of different sizes of low-contrast lesions (-15 HU), the performance of CHO with Gabor channels was highly correlated with human observer performance for the detection and localization tasks with uncertain lesion location in CT imaging at four clinically relevant dose levels. This suggests the ability of Gabor CHO model observers to meaningfully assess CT image quality for the purpose of optimizing scan protocols and radiation dose levels in detection and localization tasks for low-contrast lesions.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Incerteza , Variações Dependentes do Observador , Imagens de Fantasmas
7.
Acad Radiol ; 19(8): 916-22, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22537503

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to assess the performance of a MicroDose photon-counting full-field digital mammography (PCM) system in comparison to full-field digital mammography (FFDM) for area under the receiver-operating characteristic (ROC) curve (AUC), sensitivity, specificity, and feature analysis of standard-view mammography for women presenting for screening mammography, diagnostic mammography, or breast biopsy. MATERIALS AND METHODS: A total of 133 women were enrolled in this study at two European medical centers, with 67 women who had a pre-existing 10-36 months FFDM enrolled prospectively into the study and 66 women who underwent breast biopsy and had screening PCM and diagnostic FFDM, including standard craniocaudal and mediolateral oblique views of the breast with the lesion, enrolled retrospectively. The case mix consisted of 49 cancers, 17 biopsy-benign cases, and 67 normal cases. Sixteen radiologists participated in the reader study and interpreted all 133 cases in both conditions, separated by washout period of ≥4 weeks. ROC curve and free-response ROC curve analyses were performed for noninferiority of PCM compared to FFDM using a noninferiority margin Δ value of 0.10. Feature analysis of the 66 cases with lesions was conducted with all 16 readers at the conclusion of the blinded reads. Mean glandular dose was recorded for all cases. RESULTS: The AUC for PCM was 0.947 (95% confidence interval [CI], 0.920-0.974) and for FFDM was 0.931 (95% CI, 0.898-0.964). Sensitivity per case for PCM was 0.936 (95% CI, 0.897-0.976) and for FFDM was 0.908 (95% CI, 0.856-0.960). Specificity per case for PCM was 0.764 (95% CI, 0.688-0.841) and for FFDM was 0.749 (95% CI, 0.668-0.830). Free-response ROC curve figures of merit were 0.920 (95% CI, 0.881-0.959) and 0.903 (95% CI, 0.858-0.948) for PCM and FFDM, respectively. Sensitivity per lesion was 0.903 (95% CI, 0.846-0.960) and 0.883 (95% CI, 0.823-0.944) for PCM and FFDM, respectively. The average false-positive marks per image of noncancer cases were 0.265 (95% CI, 0.171-0.359) and 0.281 (95% CI, 0.188-0.374) for PCM and FFDM, respectively. Noninferiority P values for AUC, sensitivity (per case and per lesion), specificity, and average false-positive marks per image were all statistically significant (P < .001). The noninferiority P value for free-response ROC was <.025, from the 95% CI for the difference. Feature analysis resulted in PCM being preferred to FFDM by the readers for ≥70% of the cases. The average mean glandular dose for PCM was 0.74 mGy (95% CI, 0.722-0.759 mGy) and for FFDM was 1.23 mGy (95% CI, 1.199-1.262 mGy). CONCLUSIONS: In this study, radiologist performance with PCM was not inferior to that with conventional FFDM at an average 40% lower mean glandular dose.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Programas de Rastreamento/métodos , Fotometria/métodos , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Europa (Continente) , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Fótons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Radiology ; 263(2): 401-8, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22361006

RESUMO

PURPOSE: To conduct post-hoc analysis of National CT Colonography Trial data and compare the sensitivity and specificity of computed tomographic (CT) colonography in participants younger than 65 years with those in participants aged 65 years and older. MATERIALS AND METHODS: Of 2600 asymptomatic participants recruited at 15 centers for the trial, 497 were 65 years of age or older. Approval of this HIPAA-compliant study was obtained from the institutional review board of each site, and informed consent was obtained from each subject. Radiologists certified in CT colonography reported lesions 5 mm in diameter or larger. Screening detection of large (≥10-mm) histologically confirmed colorectal neoplasia was the primary end point; screening detection of smaller (6-9-mm) colorectal neoplasia was a secondary end point. The differences in sensitivity and specificity of CT colonography in the two age cohorts (age < 65 years and age ≥ 65 years) were estimated with bootstrap confidence intervals (CIs). RESULTS: Complete data were available for 477 participants 65 years of age or older (among 2531 evaluable participants). Prevalence of adenomas 1 cm or larger for the older participants versus the younger participants was 6.9% (33 of 477) versus 3.7% (76 of 2054) (P < .004). For large neoplasms, mean estimates for CT colonography sensitivity and specificity among the older cohort were 0.82 (95% CI: 0.644, 0.944) and 0.83 (95% CI: 0.779, 0.883), respectively. For large neoplasms in the younger group, CT colonography sensitivity and specificity were 0.92 (95% CI: 0.837, 0.967) and 0.86 (95% CI: 0.816, 0.899), respectively. Per-polyp sensitivity for large neoplasms for the older and younger populations was 0.75 (95% CI: 0.578, 0.869) and 0.84 (95% CI: 0.717, 0.924), respectively. For the older and younger groups, per-participant sensitivity was 0.72 (95% CI: 0.565, 0.854) and 0.81 (95% CI: 0.745, 0.882) for detecting adenomas 6 mm in diameter or larger. CONCLUSION: For most measures of diagnostic performance and in most subsets, the difference between senior-aged participants and those younger than 65 years was not statistically significant.


Assuntos
Colonografia Tomográfica Computadorizada , Neoplasias Colorretais/diagnóstico por imagem , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Ensaios Clínicos como Assunto , Neoplasias Colorretais/epidemiologia , Feminino , Humanos , Imageamento Tridimensional , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Sensibilidade e Especificidade , Estados Unidos/epidemiologia
9.
N Engl J Med ; 359(12): 1207-17, 2008 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-18799557

RESUMO

BACKGROUND: Computed tomographic (CT) colonography is a noninvasive option in screening for colorectal cancer. However, its accuracy as a screening tool in asymptomatic adults has not been well defined. METHODS: We recruited 2600 asymptomatic study participants, 50 years of age or older, at 15 study centers. CT colonographic images were acquired with the use of standard bowel preparation, stool and fluid tagging, mechanical insufflation, and multidetector-row CT scanners (with 16 or more rows). Radiologists trained in CT colonography reported all lesions measuring 5 mm or more in diameter. Optical colonoscopy and histologic review were performed according to established clinical protocols at each center and served as the reference standard. The primary end point was detection by CT colonography of histologically confirmed large adenomas and adenocarcinomas (10 mm in diameter or larger) that had been detected by colonoscopy; detection of smaller colorectal lesions (6 to 9 mm in diameter) was also evaluated. RESULTS: Complete data were available for 2531 participants (97%). For large adenomas and cancers, the mean (+/-SE) per-patient estimates of the sensitivity, specificity, positive and negative predictive values, and area under the receiver-operating-characteristic curve for CT colonography were 0.90+/-0.03, 0.86+/-0.02, 0.23+/-0.02, 0.99+/-<0.01, and 0.89+/-0.02, respectively. The sensitivity of 0.90 (i.e., 90%) indicates that CT colonography failed to detect a lesion measuring 10 mm or more in diameter in 10% of patients. The per-polyp sensitivity for large adenomas or cancers was 0.84+/-0.04. The per-patient sensitivity for detecting adenomas that were 6 mm or more in diameter was 0.78. CONCLUSIONS: In this study of asymptomatic adults, CT colonographic screening identified 90% of subjects with adenomas or cancers measuring 10 mm or more in diameter. These findings augment published data on the role of CT colonography in screening patients with an average risk of colorectal cancer. (ClinicalTrials.gov number, NCT00084929; American College of Radiology Imaging Network [ACRIN] number, 6664.)


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenoma/diagnóstico por imagem , Colonografia Tomográfica Computadorizada , Neoplasias Colorretais/diagnóstico por imagem , Adenocarcinoma/diagnóstico , Adenocarcinoma/patologia , Adenoma/diagnóstico , Adenoma/patologia , Idoso , Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/patologia , Colonoscopia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Sensibilidade e Especificidade
10.
Int J Radiat Oncol Biol Phys ; 67(4): 972-5, 2007 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-17208386

RESUMO

PURPOSE: Accurate target definition is considered essential for sophisticated, image-guided radiation therapy; however, relatively little information has been reported that measures our ability to identify the precise shape of targets accurately. We decided to assess the manner in which eight "experts" interpreted the size and shape of tumors based on "real-life" contrast-enhanced computed tomographic (CT) scans. METHODS AND MATERIALS: Four neuroradiologists and four radiation oncologists (the authors) with considerable experience and presumed expertise in treating head-and-neck tumors independently contoured, slice-by-slice, his/her interpretation of the precise gross tumor volume (GTV) on each of 20 sets of CT scans taken from 20 patients who previously were enrolled in Radiation Therapy Oncology Group protocol 91-11. RESULTS: The average proportion of overlap (i.e., the degree of agreement) was 0.532 (95% confidence interval 0.457 to 0.606). There was a slight tendency for the proportion of overlap to increase with increasing average GTV. CONCLUSIONS: Our work suggests that estimation of tumor shape currently is imprecise, even for experienced physicians. In consequence, there appears to be a practical limit to the current trend of smaller fields and tighter margins.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias Laríngeas/diagnóstico por imagem , Variações Dependentes do Observador , Radioterapia (Especialidade)/normas , Tomografia Computadorizada por Raios X , Competência Clínica , Feminino , Humanos , Masculino , Neurologia/normas
11.
Cancer ; 103(12): 2616-22, 2005 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-15887218

RESUMO

BACKGROUND: Prior studies have determined that macroscopic ("gross") tumor volume (GTV), as calculated from pretreatment computer tomography (CT), was capable of predicting local control in squamous cell carcinoma arising in different subsites in the head and neck in patients who were treated with nonsurgical organ-preservation therapy. The majority of these studies were single-institution, retrospective investigations. Consequently, there has been concern that GTV measurements may not be reproducible by different readers at different institutions. The objective of the current study was to measure the interobserver reliability for GTV measurements for squamous cell carcinoma of the supraglottic larynx (SGSCCA) performed by different readers at different institutions. METHODS: Eight experienced readers (4 neuroradiologists and 4 radiation oncologists) from different institutions independently measured the pretreatment GTV of 20 patients with SGSCCA. The CT scans were obtained from patients entered into the definitive radiation therapy arm of Radiation Therapy Oncology Group protocol 91-11, who had supraglottic carcinoma and underwent pretreatment CT scans of the neck. Statistical analysis focused on interobserver reliability as measured by the intraclass correlation coefficient. RESULTS: The intraclass correlation coefficient was 0.81 (95% lower confidence bound, 0.71). This value was interpreted as "excellent." CONCLUSIONS: GTV measurements were reliable and reproducible when performed by neuroradiologists and radiation oncologists who were experienced in the interpretation of CT scans of the extracranial head and neck in patients with SGSCCA. The result implied that the correlation between GTV and local control should be reproducible across institutions.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Glote/diagnóstico por imagem , Neoplasias Laríngeas/diagnóstico por imagem , Variações Dependentes do Observador , Tomografia Computadorizada por Raios X/normas , Adulto , Idoso , Carcinoma de Células Escamosas/patologia , Feminino , Glote/patologia , Humanos , Neoplasias Laríngeas/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes
12.
Gastroenterology ; 125(3): 688-95, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12949715

RESUMO

BACKGROUND & AIMS: No multicenter study has been reported evaluating the performance and interobserver variability of computerized tomographic colonography. The aim of this study was to assess the accuracy of computerized tomographic colonography for detecting clinically important colorectal neoplasia (polyps >or=10 mm in diameter) in a multi-institutional study. METHODS: A retrospective study was developed from 341 patients who had computerized tomographic colonography and colonoscopy among 8 medical centers. Colonoscopy and pathology reports provided the standard. A random sample of 117 patients, stratified by criterion standard, was requested. Ninety-three patients were included (47% with polyps >or=10 mm; mean age, 62 years; 56% men; 84% white; 40% reported colorectal symptoms; 74% at increased risk for colorectal cancer). Eighteen radiologists blinded to the criterion standard interpreted computerized tomography colonography examinations, each using 2 of 3 different software display platforms. RESULTS: The average area under the receiver operating characteristic curve for identifying patients with at least 1 lesion >or=10 mm was 0.80 (95% lower confidence bound, 0.74). The average sensitivity and specificity were 75% (95% lower confidence bound, 68%) and 73% (95% lower confidence bound, 66%), respectively. Per-polyp sensitivity was 75%. A trend was observed for better performance with more observer experience. There was no difference in performance across software display platforms. CONCLUSIONS: Computerized tomographic colonography performance compared favorably with reported performance of fecal occult blood testing, flexible sigmoidoscopy, and barium enema. A prospective study evaluating the performance of computerized tomography colonography in a screening population is indicated.


Assuntos
Colonografia Tomográfica Computadorizada , Neoplasias do Colo/diagnóstico , Pólipos do Colo/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA